Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
J Biomech ; 146: 111424, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36603366

RESUMO

Femoroacetabular impingement syndrome (FAIS) is a motion-related pathology of the hip characterized by pain, morphological abnormalities of the proximal femur, and an elevated risk of joint deterioration and hip osteoarthritis. Activities that require deep flexion are understood to induce impingement in cam FAIS patients, however, less demanding activities such as walking and pivoting may induce pain as well as alterations in kinematics and joint stability. Still, the paucity of quantitative descriptions of cam FAIS has hindered understanding underlying hip joint mechanics during such activities. Previous in silico studies have employed generalized model geometry or kinematics to simulate impingement between the femur and acetabulum, which may not accurately capture the interplay between morphology and motion. In this study, we utilized models with participant-specific bone and articular soft tissue anatomy and kinematics measured by dual-fluoroscopy to compare hip contact mechanics of cam FAIS patients to controls during four activities of daily living (internal/external pivoting and level/incline walking). Averaged across the gait cycle during incline walking, patients displayed increased strain in the anterior joint (labrum strain: p-value = 0.038, patients: 11.7 ± 6.7 %, controls: 5.0 ± 3.6 %; cartilage strain: p-value = 0.029, patients: 9.1 ± 3.3 %, controls: 4.2 ± 2.3). Patients also exhibited increased average anterior cartilage strains during external pivoting (p-value = 0.039; patients: 13.0 ± 9.2 %, controls: 3.9 ± 3.2 %]). No significant differences between patient and control contact area and strain were found for level walking and internal pivoting. Our study provides new insights into the biomechanics of cam FAIS, including spatiotemporal hip joint contact mechanics during activities of daily living.


Assuntos
Impacto Femoroacetabular , Humanos , Atividades Cotidianas , Articulação do Quadril , Acetábulo , Caminhada , Cartilagem , Dor
2.
Orthop J Sports Med ; 10(2): 23259671211073834, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35141341

RESUMO

BACKGROUND: The anterior center-edge angle (ACEA) is used to quantify anterior coverage of the femoral head by the acetabulum. However, its measurement has not been evaluated in a manner consistent with routine use, and the precise 3-dimensional (3D) anatomic location where it measures coverage is not known. PURPOSE: To determine the effect of patient positioning on ACEA measurement reliability, magnitude, and 3D location. STUDY DESIGN: Descriptive laboratory study. METHODS: Included were 18 adults; 7 participants had cam morphology and femoroacetabular impingement syndrome, and 11 participants had no radiographic evidence of hip abnormalities and no history of hip pain or injuries. Ultimately, 3D femur and pelvis models were generated from computed tomography images. Radiographs were generated with the models in different degrees of pelvic rotation, tilt, and obliquity relative to the standard false-profile view. The ACEA was measured by 2 raters by selecting the location of the bone edge on each radiograph. Selections were projected onto the pelvis model and expressed as a clockface location on the acetabular rim. The clockface was mirrored on left hips to allow a direct comparison of locations between hips. Interrater and intrarater reliability were quantified via the intraclass correlation coefficient (ICC). The effect of position on ACEA measurements and clockface locations was determined via linear regression. RESULTS: Intrarater and interrater reliability were excellent (ICC ≥0.97 for all). For every degree increase in rotation, tilt, and obliquity, the ACEA changed by +0.53°, +0.93°, and -0.04°, respectively. The mean clockface location (hour:minute:second) in the false-profile view was 2:09:32 ± 0:12:00 and changed by +0:02:08, -0:00:35, and -0:00:05 for every degree increase in rotation, tilt, and obliquity, respectively. CONCLUSION: ACEA measurements were reliable even with differences in patient positioning. Rotation and tilt were associated with notable changes in ACEA measurements. ACEA bone edge measurements mapped to the anterosuperior acetabular rim, typically in proximity to the anterior inferior iliac spine. Mapped location was most sensitive to rotation. CLINICAL RELEVANCE: Pelvic rotation and tilt affected ACEA measurements, which could alter the clinical classification and treatment of borderline abnormalities. Rotation in particular must be well controlled during patient imaging to preserve measurement reliability and accuracy and to describe coverage from the intended 3D rim location.

3.
J Electromyogr Kinesiol ; 62: 102350, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31481296

RESUMO

Scapula and humerus motion associated with common manual wheelchair tasks is hypothesized to reduce the subacromial space. However, previous work relied on either marker-based motion capture for kinematic measures, which is prone to skin-motion artifact; or ultrasound imaging for arthrokinematic measures, which are 2D and acquired in statically-held positions. The aim of this study was to use a fluoroscopy-based approach to accurately quantify glenohumeral kinematics during manual wheelchair use, and compare tasks for a subset of parameters theorized to be associated with mechanical impingement. Biplane images of the dominant shoulder were acquired during scapular plane elevation, propulsion, sideways lean, and weight-relief raise in ten manual wheelchair users with spinal cord injury. A computed tomography scan of the shoulder was obtained, and model-based tracking was used to quantify six-degree-of-freedom glenohumeral kinematics. Axial rotation and superior/inferior and anterior/posterior humeral head positions were characterized for full activity cycles and compared between tasks. The change in the subacromial space was also determined for the period of each task defined by maximal change in the aforementioned parameters. Propulsion, sideways lean, and weight-relief raise, but not scapular plane elevation, were marked by mean internal rotation (8.1°, 10.8°, 14.7°, -49.2° respectively). On average, the humeral head was most superiorly positioned during the weight-relief raise (1.6 ±â€¯0.9 mm), but not significantly different from the sideways lean (0.8 ±â€¯1.1 mm) (p = 0.191), and much of the task was characterized by inferior translation. Scaption was the only task without a defined period of superior translation on average. Pairwise comparisons revealed no significant differences between tasks for anterior/posterior position (task means range: 0.1-1.7 mm), but each task exhibited defined periods of anterior translation. There was not a consistent trend across tasks between internal rotation, superior translation, and anterior translation with reductions in the subacromial space. Further research is warranted to determine the likelihood of mechanical impingement during these tasks based on the measured task kinematics and reductions in the subacromial space.


Assuntos
Articulação do Ombro , Cadeiras de Rodas , Fenômenos Biomecânicos , Fluoroscopia , Humanos , Músculo Esquelético , Amplitude de Movimento Articular , Escápula , Articulação do Ombro/diagnóstico por imagem
4.
J Orthop Res ; 40(9): 2113-2126, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-34812545

RESUMO

Developmental dysplasia of the hip (DDH) is commonly described as reduced femoral head coverage due to anterolateral acetabular deficiency. Although reduced coverage is the defining trait of DDH, more subtle and localized anatomic features of the joint are also thought to contribute to symptom development and degeneration. These features are challenging to identify using conventional approaches. Herein, we assessed the morphology of the full femur and hemi-pelvis using an articulated statistical shape model (SSM). The model determined the morphological and pose-based variations associated with DDH in a population of Japanese females and established which of these variations predict coverage. Computed tomography (CT) images of 83 hips from 47 patients were segmented for input into a correspondence-based SSM. The dominant modes of variation in the model initially represented scale and pose. After removal of these factors through individual bone alignment, femoral version and neck-shaft angle, pelvic curvature, and acetabular version dominated the observed variation. Femoral head oblateness and prominence of the acetabular rim and various muscle attachment sites of the femur and hemi-pelvis were found to predict 3D CT-based coverage measurements (R2 = 0.5-0.7 for the full bones, R2 = 0.9 for the joint). Statement of Clinical Significance: Currently, clinical measurements of DDH only consider the morphology of the acetabulum. However, the results of this study demonstrated that variability in femoral head shape and several muscle attachment sites were predictive of femoral head coverage. These morphological differences may provide insight into improved clinical diagnosis and surgical planning based on functional adaptations of patients with DDH.


Assuntos
Displasia do Desenvolvimento do Quadril , Luxação Congênita de Quadril , Acetábulo/cirurgia , Feminino , Cabeça do Fêmur/diagnóstico por imagem , Articulação do Quadril , Humanos , Estudos Retrospectivos
5.
Shape Med Imaging (2020) ; 12474: 111-121, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33738463

RESUMO

Quantifying shape variations in articulated joints is of utmost interest to understand the underlying joint biomechanics and associated clinical symptoms. For joint comparisons and analysis, the relative positions of the bones can confound subsequent analysis. Clinicians design specific image acquisition protocols to neutralize the individual pose variations. However, recent studies have shown that even specific acquisition protocols fail to achieve consistent pose. The individual pose variations are largely attributed to the day-to-day functioning of the patient, such as gait during walk, as well as interactions between specific morphologies and joint alignment. This paper presents a novel two-step method to neutralize such patient-specific variations while simultaneously preserving the inherent relationship of the articulated joint. The resulting shape models are then used to discover clinically relevant shape variations in a population of hip joints.

6.
Clin Biomech (Bristol, Avon) ; 71: 221-229, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-32035338

RESUMO

BACKGROUND: Most individuals with spinal cord injury who use manual wheelchairs experience shoulder pain related to wheelchair use, potentially in part from mechanical impingement of soft tissue structures within the subacromial space. There is evidence suggesting that scapula and humerus motion during certain wheelchair tasks occurs in directions that may reduce the subacromial space, but it hasn't been thoroughly characterized in this context. METHODS: Shoulder motion was imaged and quantified during scapular plane elevation with/without handheld load, propulsion with/without added resistance, sideways lean, and weight-relief raise in ten manual wheelchair users with spinal cord injury using biplane fluoroscopy and computed tomography. For each position, minimum distance between rotator cuff tendon insertions (infraspinatus, subscapularis, supraspinatus) and the coracoacromial arch was determined. Tendon thickness was measured with ultrasound, and impingement risk scores were defined for each task based on frequency and amount of tendon compression. FINDINGS: Periods of impingement were identified during scapular plane elevation and propulsion but not during pressure reliefs in most participants. There was a significant effect of activity on impingement risk scores (P < 0.0001), with greatest impingement risk during scapular plane elevation followed by propulsion. Impingement risk scores were not significantly different between scapular plane elevation loading conditions (P = 0.202) or propulsion resistances (P = 0.223). The infraspinatus and supraspinatus tendons were both susceptible to impingement during scapular plane elevation (by acromion), whereas the supraspinatus was most susceptible during propulsion (by acromion and coracoacromial ligament). INTERPRETATION: The occurrence of mechanical impingement during certain manual wheelchair tasks, even without increased load/resistance, demonstrates the importance of kinematics inherent to a task as a determinant of impingement. Frequency of and technique used to complete daily tasks should be carefully considered to reduce impingement risk, which may help preserve shoulder health long-term.


Assuntos
Síndrome de Colisão do Ombro/complicações , Síndrome de Colisão do Ombro/fisiopatologia , Traumatismos da Medula Espinal/complicações , Traumatismos da Medula Espinal/fisiopatologia , Cadeiras de Rodas , Acrômio/fisiopatologia , Adulto , Fenômenos Biomecânicos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pressão , Risco , Manguito Rotador/fisiopatologia , Escápula/fisiopatologia , Articulação do Ombro/fisiopatologia , Dor de Ombro/fisiopatologia , Ultrassonografia
7.
Med Eng Phys ; 60: 109-116, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-30098937

RESUMO

Biplane 2D-3D model-based registration and radiostereometric analysis (RSA) approaches have been commonly used for measuring three-dimensional, in vivo joint kinematics. However, in clinical biplane systems, the x-ray images are acquired asynchronously, which introduces registration errors. The present study introduces an interpolation technique to reduce image registration error by generating synchronous fluoroscopy image estimates. A phantom study and cadaveric shoulder study were used to evaluate the level of improvement in image registration that could be obtained as a result of using our interpolation technique. Our phantom study results show that the interpolated bead tracking technique was in better agreement with the true bead positions than when asynchronous images were used alone. The overall RMS error of glenohumeral kinematics for interpolated biplane registration was reduced by 1.27 mm, 0.40 mm, and 0.47 mm in anterior-posterior, superior-inferior, and medial-lateral translation, respectively; and 0.47°, 0.67°, and 0.19° in ab-adduction, internal-external rotation and flexion-extension, respectively, compared to asynchronous registration. The interpolated biplane registration results were consistent with previously reported studies using custom synchronous biplane fluoroscopy technology. This approach will be particularly useful for improving the kinematic accuracy of high velocity activities when using clinical biplane fluoroscopes or two independent c-arms, which are available at a number of institutions.


Assuntos
Fluoroscopia , Imageamento Tridimensional , Articulações/diagnóstico por imagem , Fenômenos Mecânicos , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Humanos , Imagens de Fantasmas
8.
J Biomech ; 71: 306-312, 2018 04 11.
Artigo em Inglês | MEDLINE | ID: mdl-29478696

RESUMO

Model-based tracking, using CT and biplane fluoroscopy, allows highly accurate quantification of glenohumeral motion and changes in the subacromial space. Previous investigators have used custom-built biplane fluoroscopes designed specifically for kinematic applications, which are available at few institutions and require FDA approval prior to clinical use. The aim of this study was to demonstrate the utility of an off-the-shelf clinical biplane fluoroscope for kinematic applications by validating model-based tracking for measurement of glenohumeral motion using an unmodified clinical system. Biplane images of each shoulder of a cadaver torso were acquired at various joint positions and during simulated movements along anatomical planes of motion. The pose of each humerus and scapula was determined using model-based tracking and compared to a bead-based gold standard. Error due to a temporal-offset between corresponding biplane images, characteristic of clinical biplane systems, was determined by comparison of measured and known relative position of 2 bead clusters of a phantom that was imaged while moved throughout the fluoroscopy image volume. Model-based tracking had global kinematic mean absolute errors of 0.27 mm and 0.29° (static), and 0.22-0.32 mm and 0.12-0.45° (dynamic). Glenohumeral mean absolute errors were 0.39 mm and 0.45° (static), and 0.36-0.42 mm and 0.41-0.48° (dynamic). The temporal-offset was predicted to add errors of 0.06-0.85 mm and 0.05-0.28° for cadaveric trials for the speeds examined. For defined speeds, sub-millimeter and sub-degree kinematic accuracy and precision were achieved using an unmodified clinical biplane fluoroscope for quantification of glenohumeral motion.


Assuntos
Fluoroscopia/métodos , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/fisiologia , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Humanos , Úmero/diagnóstico por imagem , Úmero/fisiologia , Masculino , Movimento/fisiologia , Reprodutibilidade dos Testes , Escápula/diagnóstico por imagem , Escápula/fisiologia
10.
J Orthop Res ; 34(4): 675-82, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26363273

RESUMO

The primary objective of this study was to test the hypothesis that gleno-humeral deformity in children and adolescent with obstetrical brachial plexus palsy is three-dimensional (3D). The study also compared the metrological properties of typical two-dimensional gleno-humeral measures to the newly developed 3D measures. Thirteen individuals (age = 11.8 ± 3.3 years) with obstetrical brachial plexus palsy participated in this IRB-approved study. 3D axial magnetic resonance images were acquired for both shoulders. Glenoid and humeral models were created in order to quantify 3D glenoid version, humeral head migration, and glenoid concavity. Two-dimensional (2D) measures were acquired as recommended in the literature. All measures were completed by two observers in this observer-blind study. Compared to the non-involved side, the glenoid was more retroverted (7.91°, p = 0.003) and inferiorly oriented (7.28°, p = 0.009). The humeral head was migrated more posteriorly (5.54 mm, p = 0.007), inferiorly (-3.96 mm, p = 0.013), and medially (-3.63 mm,p = 0.002). Eleven of the 13 glenoids were concave, based on the 3D glenoid models. The concurrent validity between three- and 2D measures were highly dependent of the parameter measured, the slice level used for the 2D analysis, and the presence/absence of pathology (0.63 < r < 0.91). The standard error of measurement for the 2D anterior-posterior version (>3°) was larger than that for the 3D measure of version (<1°) on the involved side. This study clearly demonstrated that the gleno-humeral deformation in obstetrical brachial plexus palsy is 3D, emphasizing the need for 3D subject specific gleno-humeral shape analysis for follow-up and treatment plans in children with obstetrical brachial plexus palsy.


Assuntos
Traumatismos do Nascimento/patologia , Neuropatias do Plexo Braquial/patologia , Articulação do Ombro/patologia , Adolescente , Estudos de Casos e Controles , Criança , Feminino , Humanos , Imageamento Tridimensional , Masculino
11.
J Biomech ; 49(15): 3741-3745, 2016 11 07.
Artigo em Inglês | MEDLINE | ID: mdl-27769514

RESUMO

Fluoroscopic imaging has become increasingly popular to investigate total knee arthroplasty kinematics non-invasively - 3D implant models are aligned with 2D image projections, and optimized via an edge-contour alignment technique. Previous studies have quantified the accuracy of this approach, however they do not always adequately address the impact of image collection parameters. A particularly sensitive parameter is the pulse width, or exposure time per frame. At longer pulse widths, more motion is captured in a single frame; this can lead to image blur and subsequent degradation to image edge quality. Therefore, the comparative accuracy of relative joint kinematics as a function of pulse width and joint velocity needs to be defined. A limits of agreement approach was taken to define the mean differences between optoelectric kinematic measures (gold standard) and fluoroscopic methods at various pulse widths (1, 8 and 16ms) and knee velocities (50, 100 and 225°/s). The mean absolute differences between the optoelectric and fluoroscopic methods for 1ms pulse width were less than 1.5° and 0.9mm. Comparable rotational differences (1.3°) were observed for the 8ms pulse width but had larger translational differences (1.4mm). The 16ms pulse width yielded the greatest mean differences (2.0° and 1.6mm), which increased with knee flexion velocity. The importance of pulse width and velocity should not be overlooked for future studies - this parameter has proven to be a sensitive metric in the quantification of joint motion via fluoroscopy and must be identified and reported in future studies.


Assuntos
Artroplastia do Joelho , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/fisiologia , Prótese do Joelho , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Fluoroscopia , Frequência Cardíaca , Humanos , Articulação do Joelho/cirurgia , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA