Artigo em Inglês | MEDLINE | ID: mdl-39180263

RESUMO

PURPOSE: To determine if supplementing standard clinical assessments with Optical Coherence Tomography (OCT) imaging of the crystalline lens improves the accuracy and precision of lens opacity assessment and associated clinical management decisions by optometrists. METHODS: Fifty optometrists registered in the UK or Éire undertook a clinical vignette study where participants graded lens opacities and made associated clinical management decisions based on the image(s)/information displayed. Three forms of vignettes were presented: (1) Slit-lamp (SL) images of the lens, (2) SL and OCT images and (3) SL, OCT and visual function measures. Vignettes were constructed using anonymised data from 50 patients with varying cataract severity, each vignette being presented twice in a randomised order (total vignette presentations = 300). The accuracy of opacity and management decisions were evaluated using descriptive statistics and non-parametric Bland-Altman analysis where assessments from experienced clinicians were the reference. The precision of assessments was examined for each vignette form using non-parametric Bland-Altman analysis. RESULTS: All (n = 50) participants completed the study, with 36 working in primary eyecare (primary eyecare) settings and 14 in hospital eyecare services (HES). Agreement was highest where vignettes contained all clinical data (i.e., SL, OCT and visual function data-grading: 51.0%, management: 50.5%), and systematically reduced with decreasing vignette content (p < 0.001). A larger number of vignettes containing imaging and visual function measures exhibited below reference (i.e., less conservative) grading compared with vignettes containing imaging data alone (all p < 0.05). HES-based optometrists were more likely to grade lens opacities lower than clinicians working in primary eyecare (p < 0.001). Good measurement precision was evident for all vignettes, with a mean bias close to zero and limits of agreement below one grading step for all conditions. CONCLUSIONS: The addition of anterior segment OCT to SL images improved the accuracy of lens opacity grading. Structural assessment alone yielded more conservative decision making, which reversed once visual functional data was available.

2.
Ophthalmic Physiol Opt ; 43(4): 788-797, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37010917

RESUMO

PURPOSE: We have previously demonstrated the upper limit of complete spatial summation (Ricco's area) to increase in non-pathological axial myopia compared to non-myopic controls. This study sought to investigate whether temporal summation is also altered in axial myopia to determine if this aspect of visual function, like in glaucoma, is influenced by reductions in retinal ganglion cell (RGC) density. METHODS: Achromatic contrast thresholds were measured for a GIII-equivalent stimulus (0.43° diameter) of six different stimulus durations (1-24 frames, 1.1-187.8 ms) in 24 participants with axial myopia (mean spherical refractive error: -4.65D, range: -1.00D to -11.25D, mean age: 34.1, range: 21-57 years) and 21 age-similar non-myopic controls (mean spherical refractive error: +0.87D, range: -0.25D to +2.00D, mean age: 31.0, range: 18-55 years). Measurements were performed at 10° eccentricity along the 90°, 180°, 270° and 360° meridians on an achromatic 10 cd/m2 background. The upper limit of complete temporal summation (critical duration, CD) was estimated from the data with iterative two-phase regression analysis. RESULTS: There was no significant difference (p = 0.90, Mann-Whitney U-test) in median CD between myopes (median: 44.3 ms; IQR: 26.5, 51.2) and non-myopes (median: 41.6 ms; IQR: 27.3, 48.5). Despite RGC numbers underlying the stimulus being significantly lower in the myopic group (p < 0.001), no relationship was observed between the CD estimate and co-localised RGC number (Pearson's r = -0.13, p = 0.43) or ocular length (Pearson's r = -0.08, p = 0.61). CONCLUSIONS: Unlike spatial summation, temporal summation is unchanged in myopia. This contrasts with glaucoma where both temporal and spatial summation are altered. As such, perimetric methods optimised to test for anomalies of temporal summation may provide a means to differentiate between conditions causing only a reduced RGC density (e.g., myopia), and pathological processes causing both a reduced RGC density and RGC dysfunction (e.g., glaucoma).


Assuntos
Glaucoma , Miopia , Humanos , Adulto , Lactente , Campos Visuais , Testes de Campo Visual/métodos , Glaucoma/diagnóstico , Miopia/diagnóstico , Células Ganglionares da Retina
3.
Ophthalmic Physiol Opt ; 43(5): 1179-1189, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37118942

RESUMO

PURPOSE: The relationship between perimetric stimulus area and Ricco's area (RA) determines measured thresholds and the sensitivity of perimetry to retinal disease. The nature of this relationship, in addition to effect of retinal ganglion cell (RGC) number on this, is currently unknown for the adaptation conditions of mesopic microperimetry. In this study, achromatic mesopic spatial summation was measured across the central visual field to estimate RA with the number of RGCs underlying RA also being established. METHODS: Achromatic luminance thresholds were measured for six incremental spot stimuli (0.009-2.07 deg2 ) and 190.4 ms duration, at four locations, each at 2.5°, 5° and 10° eccentricity in five healthy observers (mean age 61.4 years) under mesopic conditions (background 1.58 cd/m2 ). RA was estimated using two-phase regression analysis with the number of RGCs underlying RA being calculated using normative histological RGC counts. RESULTS: Ricco's area exhibited a small but statistically insignificant increase between 2.5° and 10° eccentricity. Compared with photopic conditions, RA was larger, with the difference between RA and the Goldmann III stimulus (0.43°) being minimised. RGC number underlying RA was also higher than reported for photopic conditions (median 70 cells, IQR 36-93), with no significant difference being observed across test locations. CONCLUSIONS: Ricco's area and the number of RGCs underlying RA do not vary significantly across the central visual field in mesopic conditions. However, RA is larger and more similar to the standard perimetric Goldmann III stimulus under mesopic compared with photopic adaptation conditions. Further work is required to determine if compensatory enlargements in RA occur in age-related macular degeneration, to establish the optimal stimulus parameters for AMD-specific microperimetry.


Assuntos
Visão de Cores , Campos Visuais , Humanos , Pessoa de Meia-Idade , Células Ganglionares da Retina , Testes de Campo Visual , Análise de Regressão
4.
J Vis ; 23(4): 2, 2023 04 03.
Artigo em Inglês | MEDLINE | ID: mdl-37014658

RESUMO

Spatial summation of perimetric stimuli has been used to derive conclusions about the spatial extent of retinal-cortical convergence, mostly from the size of the critical area of summation (Ricco's area, RA) and critical number of retinal ganglion cells (RGCs). However, spatial summation is known to change dynamically with stimulus duration. Conversely, temporal summation and critical duration also vary with stimulus size. Such an important and often neglected spatiotemporal interaction has important implications for modeling perimetric sensitivity in healthy observers and for formulating hypotheses for changes measured in disease. In this work, we performed experiments on visually heathy observers confirming the interaction of stimulus size and duration in determining summation responses in photopic conditions. We then propose a simplified computational model that captures these aspects of perimetric sensitivity by modelling the total retinal input, the combined effect of stimulus size, duration, and retinal cones-to-RGC ratio. We additionally show that, in the macula, the enlargement of RA with eccentricity might not correspond to a constant critical number of RGCs, as often reported, but to a constant critical total retinal input. We finally compare our results with previous literature and show possible implications for modeling disease, especially glaucoma.


Assuntos
Testes de Campo Visual , Campos Visuais , Humanos , Testes de Campo Visual/métodos , Retina/fisiologia , Células Ganglionares da Retina/fisiologia , Células Fotorreceptoras Retinianas Cones/fisiologia
5.
Ophthalmic Physiol Opt ; 42(6): 1338-1352, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36065739

RESUMO

PURPOSE: There are several indirect methods used to estimate retinal ganglion cell (RGC) count in an individual eye, but there is limited information as to the agreement between these methods. In this work, RGC receptive field (RGC-RF) count underlying a spot stimulus (0.43°, Goldmann III) was calculated and compared using three different methods. METHODS: RGC-RF count was calculated at a retinal eccentricity of 2.32 mm for 44 healthy adult participants (aged 18-58 years, refractive error -9.75 DS to +1.75 DS) using: (i) functional measures of achromatic peripheral grating resolution acuity (PGRA), (ii) structural measures of RGC-layer thickness (OCT-model, based on the method outlined by Raza and Hood) and (iii) scaling published histology density data to simulate a global expansion in myopia (Histology-Balloon). RESULTS: Whilst average RGC-RF counts from the OCT-model (median 105.3, IQR 99.6-111.0) and the Histology-Balloon model (median 107.5, IQR 97.7-114.6) were similar, PGRA estimates were approximately 65% lower (median 37.7, IQR 33.8-46.0). However, there was poor agreement between all three methods (Bland-Altman 95% limits of agreement; PGRA/OCT: 55.4; PGRA/Histology-Balloon 59.3; OCT/Histology-Balloon: 52.4). High intersubject variability in RGC-RF count was evident using all three methods. CONCLUSIONS: The lower PGRA RGC-RF counts may be the result of targeting only a specific subset of functional RGCs, as opposed to the coarser approach of the OCT-model and Histology-Balloon, which include all RGCs, and also likely displaced amacrine cells. In the absence of a 'ground truth', direct measure of RGC-RF count, it is not possible to determine which method is most accurate, and each has limitations. However, what is clear is the poor agreement found between the methods prevents direct comparison of RGC-RF counts between studies utilising different methodologies and highlights the need to utilise the same method in longitudinal work.


Assuntos
Células Ganglionares da Retina , Campos Visuais , Adulto , Contagem de Células , Humanos , Células Ganglionares da Retina/patologia , Tomografia de Coerência Óptica
6.
Ophthalmology ; 124(3): 310-319, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-27932223

RESUMO

PURPOSE: Considerable between-individual variation in retinal ganglion cell (RGC) density exists in healthy individuals, making identification of change from normal to glaucoma difficult. In ascertaining local cone-to-RGC density ratios in healthy individuals, we wished to investigate the usefulness of objective cone density estimates as a surrogate of baseline RGC density in glaucoma patients, and thus a more efficient way of identifying early changes. DESIGN: Exploratory cohort study. PARTICIPANTS: Twenty glaucoma patients (60% women) with a median age of 54 years and mean deviation (MD) in the visual field of -5 dB and 20 healthy controls (70% women) with a median age of 57 years and a mean MD of 0 dB were included. METHODS: Glaucoma patients and healthy participants underwent in vivo cone imaging at 4 locations of 8.8° eccentricity with a modified Heidelberg Retina Angiograph HRA2 (scan angle, 3°). Cones were counted using an automated program. Retinal ganglion cell density was estimated at the same test locations from peripheral grating resolution acuity thresholds. MAIN OUTCOME MEASURES: Retinal cone density, estimated RGC density, and cone-to-RGC ratios in glaucoma patients and healthy controls. RESULTS: Median cone-to-RGC density was 3.51:1 (interquartile range [IQR], 2.59:1-6.81:1) in glaucoma patients compared with 2.35:1 (IQR, 1.83:1-2.82:1) in healthy participants. Retinal ganglion cell density was 33% lower in glaucoma patients than in healthy participants; however, cone density was very similar in glaucoma patients (7248 cells/mm2) and healthy controls (7242 cells/mm2). The area under the receiver operator characteristic curve was 0.79 (95% confidence interval [CI], 0.71-0.86) for both RGC density and cone-to-RGC ratio and 0.49 (95% CI, 0.39-0.58) for cone density. CONCLUSIONS: Local measurements of cone density do not differ significantly from normal in glaucoma patients despite large differences in RGC density. There was no statistically significant association between RGC density and cone density in the normal participants, and the range of cone-to-RGC density ratios was relatively large in healthy controls. These findings suggest that estimates of baseline RGC density from cone density are unlikely to be precise and offer little advantage over determination of RGC alone in the identification of early glaucomatous change.


Assuntos
Glaucoma de Ângulo Aberto/diagnóstico , Células Fotorreceptoras Retinianas Cones/patologia , Células Ganglionares da Retina/patologia , Contagem de Células , Estudos de Coortes , Feminino , Glaucoma de Ângulo Aberto/fisiopatologia , Voluntários Saudáveis , Humanos , Pressão Intraocular/fisiologia , Masculino , Pessoa de Meia-Idade , Doenças do Nervo Óptico/diagnóstico , Doenças do Nervo Óptico/fisiopatologia , Psicofísica , Tomografia de Coerência Óptica , Testes de Campo Visual , Campos Visuais/fisiologia
7.
Ophthalmic Physiol Opt ; 35(5): 582-90, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26303451

RESUMO

PURPOSE: To quantify the effect of cathode-tube-ray (CRT) monitor refresh rate on the measurement of the upper limit of complete temporal summation (critical duration) in the peripheral visual field of healthy observers. METHODS: Contrast thresholds were measured for seven achromatic spot stimuli (diameter 0.48°) of varying duration (nominal values: 10-200 ms) at an eccentricity of 8.8° along the 45°, 135°, 225° and 315° meridians of the visual field in three healthy, psychophysically experienced observers. Stimuli were presented on a CRT display with a refresh rate of 60 and 160 Hz. Contrast thresholds were expressed as contrast energy with stimulus durations being estimated using (1) the sum-of-frames (SOF) method and (2) Bridgeman's method incorporating measurements of phosphor persistence. Estimates of the critical duration were produced using iterative two-phase regression analysis. RESULTS: With stimulus duration expressed as SOF equivalent the critical duration was, on average, 10.6 ms longer with a refresh rate of 60 Hz (mean 45.7 ms, S.D. 10.1 ms) relative to 160 Hz (35.1 ms, S.D. 7.6 ms). When the Bridgeman method was used, minimal differences (1.8 ms) in critical duration values between the two refresh rates (60 Hz: 33.0 ms, S.D. 9.4 ms; 160 Hz: 31.2 ms, S.D. 7.0 ms) were observed. Identical trends were observed in all three subjects. CONCLUSIONS: Psychophysical measurements of temporal summation are independent of variations in CRT refresh rate when the Bridgeman method, incorporating measured values of phosphor persistence, is used to estimate stimulus duration. This has significant implications for the specification of stimulus duration in psychophysical studies of vision employing conventional display monitors.


Assuntos
Sensibilidades de Contraste/fisiologia , Psicofísica/métodos , Limiar Sensorial/fisiologia , Campos Visuais/fisiologia , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estimulação Luminosa , Testes de Campo Visual
8.
Eye (Lond) ; 38(10): 1947-1957, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38806699

RESUMO

OBJECTIVES: To validate and update the 2013 James Lind Alliance (JLA) Sight Loss and Vision Priority Setting Partnership (PSP)'s research priorities for Ophthalmology, as part of the UK Clinical Eye Research Strategy. METHODS: Twelve ophthalmology research themes were identified from the JLA report. They were allocated to five Clinical Study Groups of diverse stakeholders who reviewed the top 10 research priorities for each theme. Using an online survey (April 2021-February 2023), respondents were invited to complete one or more of nine subspecialty surveys. Respondents indicated which of the research questions they considered important and subsequently ranked them. RESULTS: In total, 2240 people responded to the survey (mean age, 59.3 years), from across the UK. 68.1% were female. 68.2% were patients, 22.3% healthcare professionals or vision researchers, 7.1% carers, and 2.1% were charity support workers. Highest ranked questions by subspecialty: Cataract (prevention), Cornea (improving microbial keratitis treatment), Optometric (impact of integration of ophthalmic primary and secondary care via community optometric care pathways), Refractive (factors influencing development and/or progression of refractive error), Childhood onset (improving early detection of visual disorders), Glaucoma (effective and improved treatments), Neuro-ophthalmology (improvements in prevention, diagnosis and treatment of neurodegeneration affecting vision), Retina (improving prevention, diagnosis and treatment of dry age-related macular degeneration), Uveitis (effective treatments for ocular and orbital inflammatory diseases). CONCLUSIONS: A decade after the initial PSP, the results refocus the most important research questions for each subspecialty, and prime targeted research proposals within Ophthalmology, a chronically underfunded specialty given the substantial burden of disability caused by eye disease.


Assuntos
Pesquisa Biomédica , Oftalmologia , Humanos , Reino Unido , Oftalmologia/organização & administração , Feminino , Masculino , Pessoa de Meia-Idade , Oftalmopatias/terapia , Oftalmopatias/diagnóstico , Inquéritos e Questionários , Prioridades em Saúde , Adulto , Idoso
9.
Eye (Lond) ; 2023 Dec 13.
Artigo em Inglês | MEDLINE | ID: mdl-38092939

RESUMO

INTRODUCTION: Hospital-based optometrists are undertaking extended roles across ophthalmology that may require them to perform advanced skills (AS). Moorfields Eye Hospital (MEH) is the largest UK employer of hospital-based optometrists, it was sought to investigate which AS are being performed at this centre and how they align to the four pillars of advanced clinical practice (ACP). METHODS: An online survey was sent to MEH optometrists in May 2022 that asked about professional status, sub-specialties worked, qualifications, acquisition and validation of AS, research and leadership. RESULTS: Ninety-six optometrists with mean post-qualification experience was 16.2 years (SD 10.4) responded to the survey. There were 84 AS that covered clinical, leadership and research, with respondents achieving a mean of 11.8 (SD 10.3). Those with independent prescribing (IP) qualifications (n = 52) had a higher number of AS compared to non-IP optometrists (p = 0.03). There were 68 clinical AS across the sub-specialties (23 clinical AS were common in ≥2 sub-specialties), 49 out of 120 clinical AS could be performed by at least 60% of staff. Twenty-six optometrists identified with leadership, 56 had undertaken research/audit, 27 had published within a peer-reviewed journal and half of the time spent in active research was funded. CONCLUSION: AS are being performed by optometrists within a tertiary eye hospital that supports ACP. IP optometrists had higher self-reported AS but current educational frameworks don't accommodate for some AS. Targeted AS courses with competency-based sign-off may further support high-quality patient care. Further research is required on how advanced care practitioners can support workforce transformation.

10.
Transl Vis Sci Technol ; 12(11): 37, 2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-38019498

RESUMO

Purpose: To measure achromatic spatial, temporal, and spatiotemporal summation in dry age-related macular degeneration (AMD) compared to healthy controls under conditions of photopic gaze-contingent perimetry. Methods: Twenty participants with dry AMD (mean age, 74.6 years) and 20 healthy controls (mean age, 67.8 years) performed custom, gaze-contingent perimetry tests. An area-modulation test generated localized estimates of Ricco's area (RA) at 2.5° and 5° eccentricities along the 0°, 90°, 180°, and 270° meridians. Contrast thresholds were measured at the same test locations for stimuli of six durations (3.7-190.4 ms) with a Goldmann III stimulus (GIII, 0.43°) and RA-scaled stimuli. The upper limit (critical duration) of complete temporal summation (using the GIII stimulus) and spatiotemporal summation (using the RA stimuli) was estimated using iterative two-phase regression analysis. Results: Median (interquartile range [IQR]) RA estimates were significantly larger in AMD participants (2.5°: 0.21 [0.09-0.41] deg2; 5°: 0.32 [0.15-0.65 deg2]) compared to healthy controls (2.5°: 0.08 [0.05-0.13] deg2; 5°: 0.15 [0.08-0.22] deg2) at all test locations (all P < 0.05). No significant difference in median critical duration was found in AMD participants with the GIII stimulus (19.6 [9.9-30.4] ms) and RA-scaled stimuli (22.9 [13.9-40.3] ms) compared to healthy controls (GIII: 17.0 [11.3-24.0] ms; RA-scaled: 22.4 [14.3-33.1] ms) at all test locations (all P > 0.05). Conclusions: Spatial summation is altered in dry AMD, without commensurate changes in temporal summation. Translational Relevance: The sensitivity of perimetry to AMD may be improved by utilizing stimuli that probe alterations in spatial summation in the disease.


Assuntos
Atrofia Geográfica , Testes de Campo Visual , Humanos , Idoso , Atrofia Geográfica/diagnóstico
11.
Invest Ophthalmol Vis Sci ; 64(14): 36, 2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-38010697

RESUMO

Purpose: The purpose of this study was to test whether functional loss in the glaucomatous macula is characterized by an enlargement of Ricco's area (RA) through the application of a computational model linking retinal ganglion cell (RGC) damage to perimetric sensitivity. Methods: One eye from each of 29 visually healthy subjects <40 years old, 30 patients with glaucoma, and 20 age-similar controls was tested with a 10-2 grid with stimuli of 5 different area sizes. Structural estimates of point-wise RGC density were obtained from optical coherence tomography (OCT) scans. Structural and functional data from the young healthy cohort were used to estimate the parameters of a computational spatial summation model to generate a template. The template was fitted with a Bayesian hierarchical model to estimate the latent RGC density in patients with glaucoma and age-matched controls. We tested two alternative hypotheses: fitting the data by translating the template horizontally (H1: change in RA) or vertically (H2: loss of sensitivity without a change in RA). Root mean squared error (RMSE) of the model fits to perimetric sensitivity were compared. Ninety-five percent confidence intervals were bootstrapped. The dynamic range of the functional and structural RGC density estimates was denoted by their 1st and 99th percentiles. Results: The RMSE was 2.09 (95% CI = 1.92-2.26) under H1 and 2.49 (95% CI = 2.24-2.72) under H2 (P < 0.001). The average dynamic range for the structural RGC density estimates was only 11% that of the functional estimates. Conclusions: Macular sensitivity loss in glaucoma is better described by a model in which RA changes with RGC loss. Structural measurements have limited dynamic range.


Assuntos
Glaucoma , Células Ganglionares da Retina , Adulto , Humanos , Teorema de Bayes , Glaucoma/diagnóstico , Tomografia de Coerência Óptica/métodos , Testes de Campo Visual , Campos Visuais , Degeneração Macular/diagnóstico
12.
Transl Vis Sci Technol ; 11(5): 4, 2022 05 02.
Artigo em Inglês | MEDLINE | ID: mdl-35511149

RESUMO

Purpose: The Moorfields Acuity Chart (MAC)-comprising pseudo-high-pass filtered "vanishing optotype" (VO) letters-is more sensitive to functional visual loss in age-related macular degeneration (AMD) compared to conventional letter charts. It is currently unknown the degree to which MAC acuity is affected by optical factors such as cataract. This is important to know when determining whether an individual's vision loss owes more to neural or optical factors. Here we estimate recognition acuity for VOs and conventional letters with simulated lens aging, achieved using different levels of induced intraocular light scatter. Methods: Recognition thresholds were determined for two experienced and one naive participant with conventional and VO letters. Stimuli were presented either foveally or at 10 degrees in the horizontal temporal retina, under varying degrees of intraocular light scatter induced by white resin opacity-containing filters (WOFs grades 1 to 5). Results: Foveal acuity only became significantly different from baseline (no filter) for WOF grade 5 with conventional letters and WOF grades 4 and 5 with VOs. In the periphery, no statistical difference was found for any stray-light level for both conventional and VOs. Conclusions: Recognition acuity measured with conventional and VOs is robust to the effects of simulated lens opacification, and thus its higher sensitivity to neural damage should not simultaneously be confounded by such optical factors. Translational Relevance: The MAC may be better able to differentiate between neural and optical deficits of visual performance, making it more suitable for the assessment of patients with AMD, who may display both types of functional visual loss.


Assuntos
Fóvea Central , Degeneração Macular , Humanos , Degeneração Macular/diagnóstico , Retina , Transtornos da Visão , Acuidade Visual
13.
Sci Rep ; 12(1): 13165, 2022 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-35915231

RESUMO

Drivers have different visual demands across varying contrast and luminance conditions. However, vision assessments for driving are typically conducted under photopic conditions. This study investigated the sensitivity of photopic and mesopic conditions to detect contrast sensitivity (CS) loss in drivers with simulated media opacities. CS was measured in forty-seven healthy drivers aged 18-50 years (mean ± SD: 25.5 ± 6.5) under photopic and mesopic-adapted luminance levels with the Pelli-Robson chart and the Mesotest II (without glare). Media opacities were simulated using white-opacity containing Lee Fog filters (1-5) and CS measured in a randomised order. A significant (p < 0.001) reduction in photopic CS (logCS) was measured with the Pelli-Robson chart only when media opacity was simulated with Fog filter 5 (1.53 ± 0.15, 2.8 triplets reduction) compared to baseline (1.95 ± 0.03). Mean mesopic CS demonstrated a significant (all p < 0.001) reduction from baseline (1.67 ± 0.14) for Fog filters 3 (1.4 triplets, 1.45 ± 0.16), 4 (2.4 triplets, 1.31 ± 0.14) and 5 (4.3 triplets, 1.02 ± 0.15). For Mesotest II, only Fog filter 5 produced a significant reduction (0.10 ± 0.09; p < 0.001) in mean mesopic CS from baseline (0.30 ± 0.01). Mesopic CS is more vulnerable to different levels of simulated media opacity, hence should be considered clinically when assessing visual function in older drivers at risk of media opacity.


Assuntos
Condução de Veículo , Visão de Cores , Sensibilidades de Contraste , Visão Mesópica
14.
Eye (Lond) ; 36(12): 2341-2345, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-34987195

RESUMO

BACKGROUND/AIMS: Amblyopia is the most common visual deficit in children and accurate visual acuity (VA) assessment is essential for diagnosis. While ETDRS high-contrast logMAR VA is the reference standard test for adults, less agreement exists for pre-literate children. A new picture optotype acuity test (The Auckland Optotypes [TAO]) has shown favourable comparison to letter acuity charts but has not yet been evaluated in children with amblyopia. This study aimed to compare VA obtained using TAO to crowded logMAR letters in children age 5-8 years with amblyopia. METHODS: Children with amblyopia (n = 54 [20.37% strabismic, 18.52% anisometropic, 61.11% mixed], mean age 78.30 ± 11.72 months) were recruited from paediatric ophthalmology/orthoptic clinics at Moorfields Eye Hospital NHS Foundation Trust, London, and Cambridge Community Services NHS Trust, Bedford. Best-corrected VA was measured in both the amblyopic eye (AE) and fellow eye (FE) using TAO and a crowded letter acuity chart. Bland-Altman analysis was used to measure 95% limits of agreement (LoA) for VA measures captured (AE, FE and interocular difference [IOD]). RESULTS: Good agreement between TAO and letter VA measurement was observed (mean bias: AE -0.01, FE 0.01, IOD -0.02). For AE measures 95% LoA were from -0.25 to 0.24 logMAR, this being similar for FE (-0.24 to 0.25) and IOD measures (-0.30 to 0.27). CONCLUSION: TAO and letters elicited similar VA in children with amblyopia. TAO could be a useful picture-based chart for paediatric vision assessment.


Assuntos
Ambliopia , Humanos , Criança , Adulto , Pré-Escolar , Ambliopia/diagnóstico , Reprodutibilidade dos Testes , Testes Visuais , Acuidade Visual , Ortóptica
15.
Am J Ophthalmol ; 217: 38-48, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32278770

RESUMO

PURPOSE: To correlate in vivo confocal microscopy morphologic features (IVCM-MF) and Acanthamoeba cyst density (ACD) with final best-corrected visual acuity (BCVA) in Acanthamoeba keratitis (AK). DESIGN: Retrospective cohort study. METHODS: Patient demographics, treatment outcome, and corresponding IVCM-MF performed at the acute stage of infection were analyzed. Inclusion criteria were microbiological positive AK cases seen at Moorfields Eye Hospital between February 2013 and October 2017. Statistical significance was assessed by multinomial regression and multiple linear regression analysis. Main outcome measure was final BCVA. RESULTS: A total of 157 eyes (157 patients) had AK. Absence of single-file round/ovoid objects was associated with a BCVA of 6/36 to 6/9 (odds ratio [OR] 8.13; 95% confidence interval [CI], 1.55-42.56, P = .013) and ≥6/6 (OR 10.50; 95% CI, 2.12-51.92, P = .004) when compared to no perception of light to 6/60. Absence of rod/spindle objects was associated with a BCVA of ≥6/6 (OR 4.55; 95% CI, 1.01-20.45, P = .048). Deep stromal/ring infiltrate was associated with single-file round/ovoid objects (OR 7.78; 95% CI, 2.69-22.35, P < .001), rod/spindle objects (OR 7.05; 95% CI, 2.11-23.59, P = .002), and binary round/ovoid objects (OR 3.45; 95% CI, 1.17-10.14, P = .024). There was a positive association between ACD and treatment duration (ß = 0.14, P = .049), number of IVCM-MF (ß = 0.34, P = .021), and clusters of round/ovoid objects (ß = 0.29, P = .002). CONCLUSIONS: Specific IVCM-MF correlate with ACD and clinical staging of disease, and are prognostic indicators for a poorer visual outcome.


Assuntos
Ceratite por Acanthamoeba/diagnóstico , Córnea/patologia , Infecções Oculares Fúngicas/diagnóstico , Microscopia Confocal/métodos , Acuidade Visual , Acanthamoeba/genética , Ceratite por Acanthamoeba/microbiologia , Ceratite por Acanthamoeba/fisiopatologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Córnea/microbiologia , DNA Fúngico/análise , Infecções Oculares Fúngicas/microbiologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Retrospectivos , Adulto Jovem
16.
Sci Rep ; 10(1): 12179, 2020 07 22.
Artigo em Inglês | MEDLINE | ID: mdl-32699286

RESUMO

This study demonstrates significant differences between the area of complete spatial summation (Ricco's area, RA) in eyes with and without non-pathological, axial myopia. Contrast thresholds were measured for six stimuli (0.01-2.07 deg2) presented at 10º eccentricity in 24 myopic subjects and 20 age-similar non-myopic controls, with RA estimated using iterative two-phase regression analysis. To explore the effects of axial length-induced variations in retinal image size (RIS) on the measurement of RA, refractive error was separately corrected with (i) trial lenses at the anterior focal point (near constant inter-participant RIS in mm), and (ii) contact lenses (RIS changed with axial length). For spectacle corrected measurements, RA was significantly larger in the myopic group, with a significant positive correlation also being observed between RA and measures of co-localised peripheral ocular length. With contact lens correction, there was no significant difference in RA between the groups and no relationship with peripheral ocular length. The results suggest RA changes with axial elongation in myopia to compensate for reduced retinal ganglion cell density. Furthermore, as these changes are only observed when axial length induced variations in RIS are accounted for, they may reflect a functional adaptation of the axially-myopic visual system to an enlarged RIS.


Assuntos
Potenciais de Ação/fisiologia , Comprimento Axial do Olho/fisiologia , Miopia/fisiopatologia , Adolescente , Adulto , Estudos de Casos e Controles , Lentes de Contato , Óculos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estimulação Luminosa , Erros de Refração , Células Ganglionares da Retina/citologia , Células Ganglionares da Retina/fisiologia , Adulto Jovem
17.
Am J Ophthalmol ; 214: 21-31, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32114180

RESUMO

PURPOSE: To determine the test-retest reliability and diagnostic accuracy of a binocular optical coherence tomography (OCT) prototype (Envision Diagnostics, El Segundo, California, USA) for pupillometry. DESIGN: Assessment of diagnostic reliability and accuracy. METHODS: Fifty participants with relative afferent pupillary defects (RAPDs) confirmed using the swinging flashlight method (mean age 49.6 years) and 50 healthy control subjects (mean age 31.3 years) were examined. Participants twice underwent an automated pupillometry examination using a binocular OCT system that presents a stimulus and simultaneously captures OCT images of the iris-pupil plane of both eyes. Participants underwent a single examination on the RAPDx (Konan Medical, Irvine, California, USA), an automated infrared pupillometer. Pupil parameters including maximum and minimum diameter, and anisocoria were measured. The magnitude of RAPD was calculated using the log of the ratio of the constriction amplitude between the eyes. A pathological RAPD was above ±0.5 log units on both devices. RESULTS: The intraclass correlation coefficient was >0.90 for OCT-derived maximum pupil diameter, minimum pupil diameter, and anisocoria. The RAPDx had a sensitivity of 82% and a specificity of 94% for detection of RAPD whereas the binocular OCT had a sensitivity of 74% and specificity of 86%. The diagnostic accuracy of the RAPDx and binocular OCT was 88% (95% confidence interval 80%-94%) and 80% (95% confidence interval 71%-87%) respectively. CONCLUSIONS: Binocular OCT-derived pupil parameters had excellent test-retest reliability. The diagnostic accuracy of RAPD was inferior to the RAPDx and is likely related to factors such as eye movement during OCT capture. As OCT becomes ubiquitous, OCT-derived measurements may provide an efficient method of objectively quantifying the pupil responses.


Assuntos
Técnicas de Diagnóstico Oftalmológico/instrumentação , Distúrbios Pupilares/diagnóstico , Pupila/fisiologia , Tomografia de Coerência Óptica/instrumentação , Visão Binocular/fisiologia , Adulto , Feminino , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Distúrbios Pupilares/fisiopatologia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Acuidade Visual/fisiologia
19.
Transl Vis Sci Technol ; 8(3): 54, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-31293809

RESUMO

PURPOSE: We provide a proof of concept for the detailed characterization of retinal capillary features and surrounding photoreceptor mosaic using a customized nonadaptive optics angiography imaging system. METHODS: High-resolution fluorescein angiography (FFA) and/or indocyanine green angiography (ICGA) images were obtained using a modified Heidelberg retina angiograph (HRA2) device with a reduced scan angle enabling 3° field of view. Colocalized images of the photoreceptor mosaic also were captured in vivo using the same instrument. Visibility of vascular subbranches were compared between high-resolution images and conventional fundus angiography (FA) with a 30° field of view. RESULTS: High-resolution angiographic and infrared images (3° × 3° field of view, a 10-fold magnification) were obtained in 10 participants. These included seven patients with various retinal diseases, including myopic degeneration, diabetic retinopathy, macular telangiectasia, and central serous chorioretinopathy, as well as three healthy controls. Images of the retinal vasculature down to the capillary level were obtained on angiography with the ability to visualize a mean 1.2 levels more subbranches compared to conventional FA. In addition, imaging of the photoreceptor cone mosaic, to a sufficient resolution to calculate cone density, was possible. Movement of blood cells within the vasculature also was discernible on infrared videography. CONCLUSIONS: This exploratory study demonstrates that fast high-resolution angiography and cone visualization is feasible using a commercially available imaging system. TRANSLATIONAL RELEVANCE: This offers potential to better understand the relationship between the retinal neurovascular system in health and disease and the timing of therapeutic interventions in disease states.

20.
Sci Rep ; 8(1): 2172, 2018 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-29391459

RESUMO

Identification of glaucomatous damage and progression by perimetry are limited by measurement and response variability. This study tested the hypothesis that the glaucoma damage signal/noise ratio is greater with stimuli varying in area, either solely, or simultaneously with contrast, than with conventional stimuli varying in contrast only (Goldmann III, GIII). Thirty glaucoma patients and 20 age-similar healthy controls were tested with the Method of Constant Stimuli (MOCS). One stimulus modulated in area (A), one modulated in contrast within Ricco's area (CR), one modulated in both area and contrast simultaneously (AC), and the reference stimulus was a GIII, modulating in contrast. Stimuli were presented on a common platform with a common scale (energy). A three-stage protocol minimised artefactual MOCS slope bias that can occur due to differences in psychometric function sampling between conditions. Threshold difference from age-matched normal (total deviation), response variability, and signal/noise ratio were compared between stimuli. Total deviation was greater with, and response variability less dependent on defect depth with A, AC, and CR stimuli, compared with GIII. Both A and AC stimuli showed a significantly greater signal/noise ratio than the GIII, indicating that area-modulated stimuli offer benefits over the GIII for identifying early glaucoma and measuring progression.