Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 59
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Opt Soc Am A Opt Image Sci Vis ; 40(3): A114-A120, 2023 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-37133021

RESUMO

Simple visual reaction times (RTs) are highly sensitive to the presence of transient activity. Transient and sustained visual mechanisms generate different RT versus contrast functions because they have different gains. To identify non-chromatic (transient) activity, we can compare RT versus contrast functions obtained with either fast or slow onset stimuli. To test this, the stimulus adopted was a temporal modulation along the red-green axis, introducing non-chromatic components by varying the red-green ratio. The technique was sensitive to departures from isoluminance for all observers; therefore, we present this method as a way to detect transient contamination in a chromatic stimulus.

2.
J Opt Soc Am A Opt Image Sci Vis ; 37(4): A163-A169, 2020 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-32400539

RESUMO

M-cone stimulation induces a pupil constriction to stimulus offset, whereas, with L cones, the pupil responds conventionally with a constriction to onset. To test the possibility that this paradox is linked to the ${\rm L}{:}{\rm M}$L:M ratio, we measured the strength of the effect by injecting a variable amount of positive or negative luminance contamination on either side of M-cone isolation and identifying a balance point at which the pupil responded equally to onset and offset. Nineteen individuals were recruited. In observers with low ${\rm L}{:}{\rm M}$L:M ratio, the paradoxical effect was weak. There was a significant relationship (${{r}^2} = {0.561}$r2=0.561) between the balance point and ${\rm L}{:}{\rm M}$L:M ratio. The effect is likely to be linked to strong inhibitory signals associated with cone-opponent pathways.


Assuntos
Pupila/fisiologia , Células Fotorreceptoras Retinianas Cones/citologia , Adulto , Feminino , Humanos , Masculino , Estimulação Luminosa , Percepção Visual/fisiologia
3.
Retina ; 40(10): 1988-1995, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31834130

RESUMO

PURPOSE: To characterize dark adaptation in patients with pseudoxanthoma elasticum, a systemic disease leading to calcification of elastic tissue including the Bruch membrane. METHODS: In this prospective case-control study, dark adaptation thresholds were measured using a Goldmann-Weekers dark adaptometer. Additional assessments included best-corrected visual acuity testing, contrast sensitivity, low luminance deficit, and vision-related quality of life. RESULTS: Dark adaptation thresholds were significantly higher, and adaptation periods were prolonged in patients with pseudoxanthoma elasticum (n = 35; 33 with 2 ABCC6 mutations) compared with controls (n = 35). The time to adapt 4 log units (20.6 ± 8.6 vs. 8.0 ± 1.3 minutes) and the mean dark adaptation threshold after 15 minutes (3.5 ± 1.1 vs. 1.8 ± 0.2 log units) were significantly different between patients and controls (both P < 0.001). Low luminance deficits (12.3 ± 6.4 vs. 6.1 ± 4.3 ETDRS letters), contrast sensitivity (1.4 ± 0.3 vs. 1.9 ± 0.1), and low luminance-related quality of life (LLQ score: 1,286 ± 355 vs. 2,167 ± 68) were also significantly worse in patients with pseudoxanthoma elasticum (all, P < 0.001). Two patients were treated with high-dose vitamin A which partially reversed impaired dark adaptation. CONCLUSION: Patients with pseudoxanthoma elasticum often have impaired dark adaptation. Positive effects of vitamin A supplementation may indicate restricted retinal access of vitamin A through the Bruch membrane as one possible underlying pathogenic factor.


Assuntos
Lâmina Basilar da Corioide/patologia , Adaptação à Escuridão/fisiologia , Pseudoxantoma Elástico/fisiopatologia , Doenças Retinianas/fisiopatologia , Adolescente , Adulto , Idoso , Estudos de Casos e Controles , Sensibilidades de Contraste/fisiologia , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Pseudoxantoma Elástico/tratamento farmacológico , Qualidade de Vida , Doenças Retinianas/tratamento farmacológico , Acuidade Visual/fisiologia , Vitamina A/administração & dosagem , Adulto Jovem
4.
J Vis ; 20(6): 20, 2020 06 03.
Artigo em Inglês | MEDLINE | ID: mdl-32589196

RESUMO

Profound vision loss occurs after prolonged exposure to an unchanging featureless visual environment. The effect is sometimes called visual fade. Here we investigate this phenomenon in the color domain using two different experiments. In the first experiment we determine the time needed for a colored background to appear achromatic. Four backgrounds were tested. Each represented the observers' four unique hues. This adaptation time was compared with time to recover after adaptation Hue shifts at the end of the adaptation period were also measured. There were wide individual differences in adaptation times and recovery times. Overall recovery was faster than adaptation (p < 0.02). There were minimal shifts in hue. In the second experiment the changes in saturation (Munsell chroma) and lightness (Munsell value) of the background were monitored at six time intervals during the adapting process. Again asymmetric matching with Munsell samples was used. There were two distinct components to both the adaptation and recovery phases; one fast with time constant <1s, the other slow with time constant between 40 and 160s. The experiments show that the special case of visual fade involving color represents the sensory basis for many color-related effects involving adaptation.


Assuntos
Adaptação Ocular/fisiologia , Percepção de Cores/fisiologia , Visão de Cores/fisiologia , Feminino , Humanos , Masculino , Estimulação Luminosa , Fatores de Tempo
5.
J Opt Soc Am A Opt Image Sci Vis ; 35(4): B66-B71, 2018 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-29603924

RESUMO

M-cone onsets appear dimmer than the background and elicit electroretinograms (ERGs) resembling the light offset response. We sought a corresponding anomalous pupillary light reflex (PLR) using a 4-primary ganzfeld as stimulator and pupillometer. Increments and decrements of white light were compared with M- and L-cone onsets and offsets using silent substitution. Luminance bias (LB) could be added to or subtracted from the cone-isolating stimuli. There was a normal PLR to L-cone increments, but the pupil constricted mainly to M-cone decrements. Changing LB produced a neutral point where on and off responses were balanced. The results reflect ERG and psychophysical studies. This observation may be linked to the antagonistic nature of the M-cone input to cone opponent mechanisms.


Assuntos
Opsinas dos Cones/fisiologia , Pupila/fisiologia , Células Fotorreceptoras Retinianas Cones/fisiologia , Adulto , Idoso , Percepção de Cores , Eletrorretinografia , Feminino , Humanos , Luz , Masculino , Pessoa de Meia-Idade , Estimulação Luminosa , Psicofísica
6.
J Opt Soc Am A Opt Image Sci Vis ; 35(4): B100-B105, 2018 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-29603927

RESUMO

Accurate color judgments rely on a powerful cognitive component. Here we compare the performance of color constancy under real and simulated conditions. Shifts in the u'v' color plane induced by illuminant A (2750 K) and illuminant S (>20,000 K) were measured using asymmetric color matching. A general linear model was used to predict performance from the following dependent variables: chroma ("4" and "6"), illuminant ("A" and "S"), presentation mode ("Real" and "Monitor"), and hue zone ("blue," "green," "yellow," "red," and "purple"). There was a strong overall effect [F(7,264)=78.65, p<0.001]. Post hoc analysis showed that performance was substantially superior under real [chromatic constancy index (cCI)=0.76] compared with simulated cCI=0.55) conditions.

7.
Exp Eye Res ; 155: 47-53, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-27890475

RESUMO

PURPOSE: The rate of rod sensitivity recovery following a photobleach is a basic measure of the integrity of the outer retina. Rods are selectively impaired in aging and many disorders of the retina, notably Age-Related Macular Degeneration (AMD). It is not known for certain whether the age-related deficit is a pan-retinal effect or if there are localised regions of impaired rod function. To address this important issue a dual arc stimulus was developed that samples sensitivity recovery in two retinal locations. METHODS: Arc-shaped stimuli were presented on a black CRT screen at two locations, in the inferior visual field. Following a bleach, which was localised to the stimuli, recovery of sensitivity was measured using a modified method of adjustment technique. Neutral density filters were used to extend the luminance range of the CRT. Sensitivity recovery functions were fitted by non-linear regression to a seven-parameter model. RESULTS: Pairs of sensitivity recovery functions were generated from the stimuli. The cone phases of these functions were identical. The slopes of the S2 sections of the curves were steeper for the outer stimuli for both young (p < 0.001) and older (p = 0.003) observers. The difference between the two was the same for the two groups. The α point was reached slightly earlier for the young observers and with the outer stimulus but neither of these effects reached statistical significance. The ß point occurred earlier for the outer stimuli and this effect was statistically significant only for the older group. CONCLUSIONS: The method places minimal demands on observers. The fact that rod sensitivity recovery is slowed in the older normal eye to the same extent in the two locations suggests that this deficit may be uniform across the retina. As there are localised losses in scotopic function in AMD, the technique is ideally suited to distinguishing impaired recovery dynamics due to normal ageing from those caused by disease.


Assuntos
Envelhecimento , Adaptação à Escuridão/fisiologia , Degeneração Macular/fisiopatologia , Retina/fisiopatologia , Acuidade Visual , Adulto , Idoso , Feminino , Humanos , Degeneração Macular/diagnóstico , Masculino , Estimulação Luminosa , Retina/patologia , Células Fotorreceptoras Retinianas Cones/fisiologia , Células Fotorreceptoras Retinianas Bastonetes/fisiologia , Campos Visuais
8.
J Opt Soc Am A Opt Image Sci Vis ; 33(3): A207-13, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26974925

RESUMO

We investigated the brightness (i.e., perceived luminance) of isolated L- and M-cone pulses to seek a perceptual correlate of our previous reports that M-on electroretinograms resemble L-off responses, implying the operation of post-receptoral opponent processing. Using triple silent substitutions, cone increments were generated in a 4-primary ganzfeld, masked by random positive or negative luminance bias. The results show that M-cone increments decrease in brightness, while L-cone increments increase. These differences became smaller as field size reduced; this was not eccentricity or area dependent. We speculate about early retinal input into brightness perception.


Assuntos
Luz , Células Fotorreceptoras Retinianas Cones/citologia , Células Fotorreceptoras Retinianas Cones/efeitos da radiação , Humanos , Estimulação Luminosa , Psicofísica , Percepção Visual/efeitos da radiação
9.
J Opt Soc Am A Opt Image Sci Vis ; 33(3): A1-11, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26974913

RESUMO

An overview of electroretinogram response components to incremental and decremental steps in L- and M-cone excitation was obtained in human observers, while varying the spatial properties of the stimulus. Responses to L- and M-cone stimuli of opposite polarity resembled each other, particularly within the central 35° of the retina. All amplitudes grew as stimulus size increased; however, earlier and later components of the On- and Off-responses showed differing degrees of dependency on stimulus size. Thus, they may reflect different proportions of responses originating in parvocellular (less stimulus size-dependent) and magnocellular (more stimulus size-dependent) streams.


Assuntos
Estimulação Luminosa , Células Fotorreceptoras Retinianas Cones/citologia , Percepção Visual/fisiologia , Adulto , Eletrorretinografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
10.
Graefes Arch Clin Exp Ophthalmol ; 254(5): 891-9, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26899899

RESUMO

PURPOSE: Many eye diseases require on-going assessment for optimal management, creating an ever-increasing burden on patients and hospitals that could potentially be reduced through home vision monitoring. However, there is limited evidence for the utility of current applications and devices for this. To address this, we present a new automated, computer tablet-based method for self-testing near visual acuity (VA) for both high and low contrast targets. We report on its reliability and agreement with gold standard measures. METHODS: The Mobile Assessment of Vision by intERactIve Computer (MAVERIC) system consists of a calibrated computer tablet housed in a bespoke viewing chamber. Purpose-built software automatically elicits touch-screen responses from subjects to measure their near VA for either low or high contrast acuity. Near high contrast acuity was measured using both the MAVERIC system and a near Landolt C chart in one eye for 81 patients and low contrast acuity using the MAVERIC system and a 25 % contrast near EDTRS chart in one eye of a separate 95 patients. The MAVERIC near acuity was also retested after 20 min to evaluate repeatability. RESULTS: Repeatability of both high and low contrast MAVERIC acuity measures, and their agreement with the chart tests, was assessed using the Bland-Altman comparison method. One hundred and seventy-three patients (96 %) completed the self- testing MAVERIC system without formal assistance. The resulting MAVERIC vision demonstrated good repeatability and good agreement with the gold-standard near chart measures. CONCLUSIONS: This study demonstrates the potential utility of the MAVERIC system for patients with ophthalmic disease to self-test their high and low contrast VA. The technique has a high degree of reliability and agreement with gold standard chart based measurements.


Assuntos
Computadores de Mão , Sensibilidades de Contraste/fisiologia , Diagnóstico por Computador/instrumentação , Autocuidado/métodos , Transtornos da Visão/diagnóstico , Testes Visuais/instrumentação , Acuidade Visual/fisiologia , Algoritmos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Software
11.
Exp Eye Res ; 125: 256-61, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25016055

RESUMO

Poor vision in low light is a common complaint of elderly people. This poorly understood phenomenon is likely to involve both receptoral and post receptoral mechanisms. We investigated the recovery of contrast thresholds for sine-wave gratings of low spatial frequencies and low mean luminance as a function of time in darkness after photo pigment bleaching. Thirteen subjects aged 30.4 (±10.7) years took part in the study. Contrast thresholds were measured for 15 min following almost complete photo pigment bleaching. The stimuli were achromatic sinusoidal gratings of 0.5, 1 and 2 cycle per degree (cpd) generated on a CRT monitor. They had mean luminance 0.01 cd m(-2) and subtended 10° in diameter. The dynamics of the recovery at each spatial frequency were modelled using monophasic and biphasic exponential decay functions. The data were best modelled by a bi-phasic decay with a distinct transition point around 7 min after the bleach. Both phases followed an exponential decay. The time constant (mean, standard error) for the first phase was 0.35 (0.04) min while for the second phase it was 5.15 (0.27) min. This difference was statistically significant (p < 0.001). A control experiment revealed the second, slower phase was mediated by rod photoreceptors. Maximum contrast sensitivity was reached 15 min after a photic bleach. The dynamics of contrast sensitivity recovery follow two phases and these may be attributed to the cone and rod systems.


Assuntos
Sensibilidades de Contraste/fisiologia , Adaptação à Escuridão/fisiologia , Células Fotorreceptoras Retinianas Bastonetes/fisiologia , Limiar Sensorial/fisiologia , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estimulação Luminosa , Recuperação de Função Fisiológica/fisiologia
12.
J Opt Soc Am A Opt Image Sci Vis ; 31(4): A113-20, 2014 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-24695158

RESUMO

Cone isolating stimuli were used to assess the temporal frequency response characteristics of L- and M-cone electroretinograms (ERGs) in nine trichromatic and four dichromatic human observers. The stimuli comprised sinusoidal temporal modulations varying from 5 to 100 Hz. ERGs were recorded using corneal fiber electrodes and subjected to fast Fourier transform analysis. At low temporal frequencies (<10 Hz) the L- and M-cone ERGs had similar amplitude and exhibited minimal differences in apparent latency. At higher flicker rates (>20 Hz) L-cone ERGs had greater amplitudes and shorter apparent latencies than the M-cone responses. These differences between the L- and M-cone ERGs are consistent with their mediation by chromatic and luminance postreceptoral processing pathways at low and high temporal frequencies, respectively.


Assuntos
Células Fotorreceptoras Retinianas Cones/citologia , Adolescente , Adulto , Criança , Eletrorretinografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo , Adulto Jovem
13.
J Opt Soc Am A Opt Image Sci Vis ; 31(4): A170-8, 2014 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-24695166

RESUMO

L- and M-cone driven on- and off- ERG responses and their interactions were examined using full field stimuli with sawtooth temporal profiles. The effects of temporal frequency and contrast were studied. ERG recordings were obtained from 21 trichromatic, 1 protanopic, and 1 deuteranopic subjects. ERGs to L-cone increments and decrements resembled those to M-cone decrements and increments, respectively (i.e., of the opposite polarity). Temporal frequency and contrast had little effect on the implicit times. All response components varied linearly with contrast. When stimulated simultaneously, the responsivities of most components were larger for counterphase than for inphase modulation. The retinal processing leading to an ERG response is reversed for L- and M-cone driven responses.


Assuntos
Eletrorretinografia/métodos , Estimulação Luminosa , Células Fotorreceptoras Retinianas Cones/citologia , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo , Adulto Jovem
14.
J Opt Soc Am A Opt Image Sci Vis ; 31(4): A159-69, 2014 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-24695165

RESUMO

Electroretinograms (ERGs) elicited by transient, square-wave L- and M-cone isolating stimuli were recorded from human trichromatic (n=19) and dichromatic (n=4) observers. The stimuli were generated on a four primary LED stimulator and were equated in terms of cone modulation (cone contrast=0.11) and retinal illuminance (12,000 trolands). L- and M-cone isolated ERGs had waveforms similar to those observed for luminance responses. However, M-cone ERGs exhibited a phase reversal in their responses to onset and offset stimuli relative to the L-cone responses. This on-off response reversal was observed in trichromats but not dichromats. Simultaneous counterphase and inphase combinations of L- and M-cone isolating stimuli generated responses that reflected chromatic and luminance processing, respectively. We conclude that L- and M-cone specific ERGs provide a measure of how photoreceptors contribute to postreceptoral mechanisms.


Assuntos
Percepção de Cores/fisiologia , Retina/fisiologia , Adolescente , Adulto , Criança , Eletrorretinografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estimulação Luminosa , Células Fotorreceptoras Retinianas Cones/citologia , Adulto Jovem
15.
Graefes Arch Clin Exp Ophthalmol ; 252(4): 657-63, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24413682

RESUMO

PURPOSE: To investigate whether macular pigment optical density (MPOD) is related to dark adaptation in healthy subjects. METHODS: Dark adaptation was measured after a minimum 30 % pigment bleach in 33 subjects (aged 15-68), using a white 1° stimulus presented 11° below fixation on a cathode ray tube monitor. The luminance range of the monitor was extended using neutral density filters. A heterochromatic flicker photometry based instrument (MPS 9000) was used to measure MPOD. RESULTS: The average MPOD for the whole group was 0.37 ± 0.21 optical density units. Subjects with lighter irides had on average 40 % lower MPOD compared to those with darker irides (0.3 ± 0.20 vs 0.5 ± 0.19). Group mean MPOD was weakly associated with second (r = 0.32, p = 0.07) and third rod-mediated recovery rates (r = 0.31, p = 0.08) and with the rod threshold (r = -0.24, p = 0.18) 30 min after the onset of bleach. MPOD was unrelated to cone time constant (r = -0.02, p = 0.91), cone threshold (r = -0.01, p = 0.96), rod-cone break (r = 0.13, p = 0.45) or the rod-rod break (r = 0.11, p = 0.52). The second rod-mediated recovery rate (S2) for the lower 10th percentile of MPOD (n = 4) was 0.18 log cd.m(-2).min(-1) and 0.24 log cd.m(-2).min(-1) for the upper 10th percentile (n = 4). The two groups were significantly different (t = -2.67, p = 0.037). CONCLUSIONS: We report a statistically significant difference between subjects falling in the 10th percentile extremes of MPOD and rod-mediated but not cone-mediated sensitivity recovery. Further investigation into the relationship between MPOD and rod function is warranted, particularly extending the work to encompass those with low MPOD and poor night vision.


Assuntos
Adaptação à Escuridão/fisiologia , Luteína/metabolismo , Células Fotorreceptoras de Vertebrados/fisiologia , Pigmentos da Retina/metabolismo , Xantofilas/metabolismo , Adolescente , Adulto , Idoso , Envelhecimento/fisiologia , Cor de Olho , Feminino , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Fotometria/métodos , Inquéritos e Questionários , Acuidade Visual , Adulto Jovem , Zeaxantinas
16.
Graefes Arch Clin Exp Ophthalmol ; 251(10): 2355-62, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23912797

RESUMO

BACKGROUND: Macular pigment (MP) might provide some protection against age-related eye disease, and it is now being measured in ophthalmic practice. The purpose of the survey described here was to determine the distribution of MP in a random population of patients in a typical UK ophthalmic practice. METHODS: Macular pigment optical density (MPOD) was measured in 56 patients aged 11 to 87 years, mean 52 ± 19, over a 3-month period. Typically, the test requires setting flicker thresholds for a centrally and peripherally viewed blue/green alternating target. Here we describe the results when an age-based estimate of the peripheral value is used, thus avoiding the peripheral setting. In 32 observers, a comparison was made between this and values obtained with the centre and periphery method. Information on smoking habits, iris colour, diabetic status, and ethnicity were recorded. RESULTS: The overall average MPOD for the population obtained with the centre-only approach for 56 individuals was 0.400 ± 0.165. The centre-only technique was an accurate predictor of values based on centre and peripheral measures, with 95% limits of agreement of 0.137 OD units. Pearson's correlation coefficient showed a high correlation between right and left eyes (r = 0.7 (p < 0.001)). There was a small difference between males and females that did not reach statistical significance (r = -0.22). There was a non-statistically significant age-related decline in MPOD in this particular population (r = -0.17). Dark irides were significantly associated with high MPOD (r = 0.28, p < 0.05). MPOD in Type II diabetic patients was 27% lower than that in non-diabetics (r = 0.29, p < 0.05). CONCLUSION: The technique provides similar values of MP optical density to previous reports. As with other HFP-based methods, in a small percentage of older patients, more than one measurement is required before satisfactory results are obtained.


Assuntos
Luteína/metabolismo , Retina/metabolismo , Pigmentos da Retina/metabolismo , Xantofilas/metabolismo , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Envelhecimento/fisiologia , Criança , Etnicidade , Cor de Olho , Feminino , Inquéritos Epidemiológicos , Humanos , Masculino , Pessoa de Meia-Idade , Optometria , Fotometria/métodos , Prática Privada , Estudos Retrospectivos , População Urbana , Adulto Jovem , Zeaxantinas
17.
Graefes Arch Clin Exp Ophthalmol ; 251(7): 1821-7, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23553287

RESUMO

PURPOSE: To characterize the rate of rod-mediated sensitivity decline with age using a PC-driven cathode ray tube (CRT) monitor. To provide data regarding the repeatability of the technique. METHODS: Dark adaptation was monitored for 30 min following a minimum 30 % pigment bleach, using a white 1° stimulus (modulated at 1 Hz), presented 11° below fixation on a CRT monitor. Thirty-three subjects with no ocular pathology and normal fundus photographs were divided into two groups: older (≥45, n = 16) and younger (<45, n = 17). RESULTS: Rod recovery was assessed using component S2 of dark adaptation. S2 was significantly slower in the older (0.19 ± 0.03 log cd.m(-2).min(-1)) compared with the younger group (0.23 ± 0.03 log cd.m(-2).min(-1), t = -4.05, p < 0.0003), despite no difference in visual acuity and fundus appearance. Faster rates of S2 recovery were correlated with lower threshold at 30 min (T30) (r = -0.49). Correlation coefficients between first and second measurements for S2 and T30 were 0.49 (p < 0.009) and 0.84 (p < 0.0001) respectively. The coefficient of repeatability was 0.07 log cd.m(-2).min(-1) for S2 and 0.35 log cd.m(-2) for T30. The coefficients of variation for S2 and T30 were 15 % and 10 % respectively. CONCLUSIONS: Dark adaptation is slowed in normal ageing. CRT-based dark adaptometry is easily implemented and highly repeatable. The technique described in this article would be useful for documenting visual changes in future clinical trials assessing retinal health in the older eye with and without ocular pathology.


Assuntos
Envelhecimento/fisiologia , Adaptação à Escuridão/fisiologia , Técnicas de Diagnóstico Oftalmológico , Células Fotorreceptoras Retinianas Bastonetes/fisiologia , Adolescente , Adulto , Idoso , Tubo de Raio Catódico , Feminino , Fixação Ocular/fisiologia , Humanos , Masculino , Microcomputadores , Pessoa de Meia-Idade , Estimulação Luminosa , Reprodutibilidade dos Testes , Acuidade Visual/fisiologia , Adulto Jovem
18.
J Physiol ; 590(13): 3141-54, 2012 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-22586211

RESUMO

The parallel processing of information forms an important organisational principle of the primate visual system. Here we describe experiments which use a novel chromatic­achromatic temporal compound stimulus to simultaneously identify colour and luminance specific signals in the human electroretinogram (ERG). Luminance and chromatic components are separated in the stimulus; the luminance modulation has twice the temporal frequency of the chromatic modulation. ERGs were recorded from four trichromatic and two dichromatic subjects (1 deuteranope and 1 protanope). At isoluminance, the fundamental (first harmonic) response was elicited by the chromatic component in the stimulus. The trichromatic ERGs possessed low-pass temporal tuning characteristics, reflecting the activity of parvocellular post-receptoral mechanisms. There was very little first harmonic response in the dichromats' ERGs. The second harmonic response was elicited by the luminance modulation in the compound stimulus and showed, in all subjects, band-pass temporal tuning characteristic of magnocellular activity. Thus it is possible to concurrently elicit ERG responses from the human retina which reflect processing in both chromatic and luminance pathways. As well as providing a clear demonstration of the parallel nature of chromatic and luminance processing in the human retina, the differences that exist between ERGs from trichromatic and dichromatic subjects point to the existence of interactions between afferent post-receptoral pathways that are in operation from the earliest stages of visual processing.


Assuntos
Visão de Cores/fisiologia , Retina/fisiologia , Adulto , Eletrorretinografia , Humanos , Masculino , Pessoa de Meia-Idade , Estimulação Luminosa
19.
J Opt Soc Am A Opt Image Sci Vis ; 29(2): A233-9, 2012 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-22330384

RESUMO

A characteristic shift in hue and saturation occurs when colored targets are viewed peripherally compared with centrally. Four hues, one in each of the red, blue, green, and yellow regions of color space, remain unchanged when presented in the peripheral field. Apart from green, these peripherally invariant hues correspond almost exactly in color space with the unique hues. We explore this puzzling observation using asymmetric color-matching and color-naming experiments and computing cone contrasts for peripheral and central stimuli. We find that the difference between cone contrasts for the peripheral and central stimuli reaches a maximum at the chromatic axis corresponding to peripherally invariant green. We speculate that the effect is linked to a weakened signal from M-cones and probably associated with a reduced number of M-cones in peripheral retina.


Assuntos
Testes de Percepção de Cores/métodos , Visão de Cores/fisiologia , Sensibilidades de Contraste/fisiologia , Células Fotorreceptoras Retinianas Cones/citologia , Testes de Campo Visual/métodos , Adulto , Cor , Humanos , Estimulação Luminosa
20.
J Opt Soc Am A Opt Image Sci Vis ; 29(2): A275-89, 2012 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-22330390

RESUMO

Cone contrast remains constant, when the same object/background is seen under different illuminations-the von Kries rule [Shevell, Vis. Res. 18, 1649 (1978)]. Here we explore this idea using asymmetric color matching. We find that von Kries adaptation holds, regardless of whether chromatic constancy index is low or high. When illumination changes the stimulus luminance (reflectance), lightness constancy is weak and matching is dictated by object/background luminance contrast. When this contrast is masked or disrupted, lightness constancy mechanisms are more prominent. Thus von Kries adaptation is incompatible with lightness constancy, suggesting that cortical mechanisms must underlie color constancy, as expected from neurophysiological studies [Zeki, Nature 284, 412 (1980); Wild, Nature 313, 133 (1985)].


Assuntos
Adaptação Ocular/fisiologia , Percepção de Cores/fisiologia , Adulto , Cor , Feminino , Humanos , Modelos Lineares , Masculino , Células Fotorreceptoras Retinianas Cones/citologia , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA