Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 54
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Magn Reson Imaging ; 57(6): 1815-1818, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36315131

RESUMO

BACKGROUND: Ferumoxytol, an intravenous iron supplement, is commonly used to treat anemia in pregnancy. Ferumoxytol-enhanced magnetic resonance angiography (Fe-MRA) is a viable off-label alternative to gadolinium-enhanced MRA for assessment of pulmonary embolism (PE) in pregnancy. PURPOSE: To describe our clinical experience with Fe-MRA in pregnant women with suspected PE. STUDY TYPE: Retrospective, observational, cohort. POPULATION: A total of 98 Fe-MRA exams (consecutive sample) performed in 94 pregnant women. FIELD STRENGTH/SEQUENCE: A 1.5 T and 3.0 T, 3D T1-weighted MRA. ASSESSMENT: After IRB approval including a waiver of informed consent, electronic health records were reviewed retrospectively for all Fe-MRA exams performed at our institution in pregnant between January, 2017 and March, 2022. The Fe-MRA protocol included 3D-MRA for assessment of pulmonary arteries, and T1-weighted imaging for ancillary findings. Fe-MRA exam duration was measured from image time stamps. Fe-MRA exams were reviewed by three cardiovascular imagers using a 4-point Likert scale for image quality and confidence for PE diagnosis (score 4 = best, 1 = worst), and tabulation of ancillary findings. STATISTICAL TESTS: Continuous data are presented as mean ± standard deviation. The overall image quality and confidence score is given as the mean of three readers. RESULTS: The 98 Fe-MRA exams were performed in 94 pregnant women (age 30 ± 6, range 19-48 years, gestational week 23 ± 10, range 3-38 weeks), with four undergoing two Fe-MRA exams during their pregnancy. Median Fe-MRA exam durration was 8 minutes (interquantile range 6 minutes). Overall image quality score was 3.3 ± 0.9. Confidence score for diagnosing PE was 3.5 ± 0.8. One subject was positive for PE (1/94, 1%); 42 of the 94 (45%) subjects Fe-MRA had ancillary findings including hydronephrosis or pneumonia. CONCLUSION: Ferumoxytol enhanced MRA is a radiation- and gadolinium-free alternative for diagnosis of PE during pregancy. EVIDENCE LEVEL: 4 TECHNICAL EFFICACY: Stage 5.


Assuntos
Óxido Ferroso-Férrico , Embolia Pulmonar , Gravidez , Humanos , Feminino , Lactente , Angiografia por Ressonância Magnética/métodos , Meios de Contraste , Estudos Retrospectivos , Pulmão , Embolia Pulmonar/diagnóstico por imagem
2.
AJR Am J Roentgenol ; 221(6): 736-746, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37341181

RESUMO

BACKGROUND. Closure of a GE Healthcare facility in Shanghai, China, in 2022 disrupted the iodinated contrast media supply. Technologic advances have addressed limitations associated with the use of pulmonary MRA for diagnosis of pulmonary embolism (PE). OBJECTIVE. The purpose of this study was to describe a single institution's experience in the use of pulmonary MRA as an alternative to CTA for the diagnosis of PE in the general population during the iodinated contrast media shortage in 2022. METHODS. This retrospective single-center study included all CTA and MRA examinations performed to exclude PE from April 1 through July 31 (18 weekly periods) in 2019 (before the COVID-19 pandemic and contrast media shortage), 2021 (during the pandemic but before the shortage), and 2022 (during both the pandemic and the shortage). From early May through mid-July of 2022, MRA served as the preferred test for PE diagnosis, to preserve iodinated contrast media. CTA and MRA reports were reviewed. The total savings in iodinated contrast media volume resulting from preferred use of MRA was estimated. RESULTS. The study included 4491 examinations of 4006 patients (mean age, 57 ± 18 [SD] years; 1715 men, 2291 women): 1245 examinations (1111 CTA, 134 MRA) in 2019, 1547 examinations (1403 CTA, 144 MRA) in 2021, and 1699 examinations (1282 CTA, 417 MRA) in 2022. In 2022, the number of MRA examinations was four (nine when normalized to a 7-day period) in week 1, and this number increased to a maximum of 63 in week 10 and then decreased to 10 in week 18. During weeks 8-11, more MRA examinations (range, 45-63 examinations) than CTA examinations (range, 27-46 examinations) were performed. In 2022, seven patients with negative MRA underwent subsequent CTA within 2 weeks; CTA was negative in all cases. In 2022, 13.9% of CTA examinations (vs 10.3% of MRA examinations) were reported as having limited image quality. The estimated 4-month savings resulting from preferred use of MRA in 2022, under the assumption of uniform simple linear growth in CTA utilization annually and a CTA dose of 1 mL/kg, was 27 L of iohexol (350 mg I/mL). CONCLUSION. Preferred use of pulmonary MRA for PE diagnosis in the general population helped to conserve iodinated contrast media during the 2022 shortage. CLINICAL IMPACT. This single-center experience shows pulmonary MRA to be a practical substitute for pulmonary CTA in emergency settings.


Assuntos
Meios de Contraste , Embolia Pulmonar , Masculino , Humanos , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Estudos Retrospectivos , Pandemias , Angiografia por Ressonância Magnética/métodos , China , Embolia Pulmonar/diagnóstico por imagem
3.
Radiology ; 303(1): 184-190, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34931858

RESUMO

Background Airway mucus plugs in asthma are associated with exacerbation frequency, increased eosinophilia, and reduced lung function. The relationship between mucus plugs and spatially overlapping ventilation abnormalities observed at hyperpolarized gas MRI has not been assessed quantitatively. Purpose To assess regional associations between CT mucus plugs scored by individual bronchopulmonary segment and corresponding measurements of segmental ventilation defect percentage (VDP) at hyperpolarized helium 3 (3He) MRI. Materials and Methods In this secondary analysis of a Health Insurance Portability and Accountability Act-compliant prospective observational cohort, participants in the Severe Asthma Research Program (SARP) III (NCT01760915) between December 2012 and August 2015 underwent hyperpolarized 3He MRI to determine segmental VDP. Segmental mucus plugs at CT were scored by two readers, with segments scored as plugged only if both readers agreed independently. A linear mixed-effects model controlling for interpatient variability was then used to assess differences in VDP in plugged versus plug-free segments. Results Forty-four participants with asthma were assessed (mean age ± standard deviation, 47 years ± 15; 29 women): 19 with mild-to-moderate asthma and 25 with severe asthma. Mucus plugs were observed in 49 total bronchopulmonary segments across eight of 44 patients. Segments containing mucus plugs had a median segmental VDP of 25.9% (25th-75th percentile, 7.3%-38.3%) versus 1.4% (25th-75th percentile, 0.1%-5.2%; P < .001) in plug-free segments. Similarly, the model estimated a segmental VDP of 18.9% (95% CI: 15.7, 22.2) for mucus-plugged segments versus 5.1% (95% CI: 3.3, 7.0) for plug-free segments (P < .001). Participants with one or more mucus plugs had a median whole-lung VDP of 11.1% (25th-75th percentile, 7.1%-18.9%) versus 3.1% (25th-75th percentile, 1.1%-4.4%) in those without plugs (P < .001). Conclusion Airway mucus plugging at CT was associated with reduced ventilation in the same bronchopulmonary segment at hyperpolarized helium 3 MRI, suggesting that mucus plugging may be an important cause of ventilation defects in asthma. © RSNA, 2021 Online supplemental material is available for this article.


Assuntos
Asma , Transtornos Respiratórios , Asma/diagnóstico por imagem , Feminino , Hélio , Humanos , Pulmão , Imageamento por Ressonância Magnética/métodos , Masculino , Muco/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos
4.
Radiology ; 290(1): 229-237, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30351258

RESUMO

Purpose To compare the performance of three-dimensional radial ultrashort echo time (UTE) oxygen-enhanced (OE) MRI with that of hyperpolarized helium 3 (3He) MRI with respect to quantitative ventilation measurements in patients with cystic fibrosis (CF). Materials and Methods In this prospective study conducted from June 2013 to May 2015, 25 participants with CF aged 10-55 years (14 male; age range, 13-55 years; 11 female; age range, 10-37 years) successfully underwent pulmonary function tests, hyperpolarized 3He MRI, and OE MRI. OE MRI used two sequential 3.5-minute normoxic and hyperoxic steady-state free-breathing UTE acquisitions. Seven participants underwent imaging at two separate examinations 1-2 weeks apart to assess repeatability. Regional ventilation was quantified as ventilation defect percentage (VDP) individually from OE MRI and hyperpolarized 3He MRI by using the same automated quantification tool. Bland-Altman analysis, intraclass correlation coefficient (ICC), Spearman correlation coefficient, and Wilcoxon signed-rank test were used to evaluate repeatability. Results In all 24 participants, the global VDP measurements from either OE MRI (ρ = -0.66, P < .001) or hyperpolarized 3He MRI (ρ = -0.75, P < .001) were significantly correlated with the percentage predicted forced expiratory volume in 1 second. VDP reported at OE MRI was 5.0% smaller than (P = .014) but highly correlated with (ρ = 0.78, P < .001) VDP reported at hyperpolarized 3He MRI. Both OE MRI-based VDP and hyperpolarized 3He MRI-based VDP demonstrated good repeatability (ICC = 0.91 and 0.95, respectively; P ≤ .001). Conclusion In lungs with cystic fibrosis, ultrashort echo time oxygen-enhanced MRI showed similar performance compared with hyperpolarized 3He MRI for quantitative measures of ventilation defects and their repeatability. © RSNA, 2018 Online supplemental material is available for this article.


Assuntos
Fibrose Cística/diagnóstico por imagem , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Adolescente , Adulto , Criança , Feminino , Hélio/administração & dosagem , Hélio/uso terapêutico , Humanos , Isótopos/administração & dosagem , Isótopos/uso terapêutico , Pulmão/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Oxigênio/metabolismo , Estudos Prospectivos , Reprodutibilidade dos Testes , Adulto Jovem
5.
Magn Reson Med ; 82(5): 1660-1670, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31228293

RESUMO

PURPOSE: To evaluate the feasibility of ferumoxytol (FE)-enhanced UTE-MRA for depiction of the pulmonary vascular and nonvascular structures. METHODS: Twenty healthy volunteers underwent contrast-enhanced pulmonary MRA at 3 T during 2 visits, separated by at least 4 weeks. Visit 1: The MRA started with a conventional multiphase 3D T1 -weighted breath-held spoiled gradient-echo MRA before and after the injection of 0.1 mmol/kg gadobenate dimeglumine (GD). Subsequently, free-breathing GD-UTE-MRA was acquired as a series of 3 flip angles (FAs) (6°, 12°, 18°) to optimize T1 weighting. Visit 2: After the injection of 4 mg/kg FE, MRA was performed during the steady state, starting with a conventional 3D T1 -weighted breath-held spoiled gradient-echo MRA and followed by free-breathing FE-UTE-MRA, both at 4 different FAs (6°, 12°, 18°, 24°). The optimal FA for best T1 contrast was evaluated. Image quality at the optimal FA was compared between methods on a 4-point ordinal scale, using multiphase GD conventional pulmonary MRA (cMRA) as standard of reference. RESULTS: Flip angle in the range of 18°-24° resulted in best T1 contrast for FE cMRA and both UTE-MRA techniques (p > .05). At optimized FA, image quality of the vasculature was good/excellent with both FE-UTE-MRA and GD cMRA (98% versus 97%; p = .51). Both UTE techniques provided superior depiction of nonvascular structures compared with either GD-enhanced or FE-enhanced cMRA (p < .001). However, GD-UTE-MRA showed the lowest image quality of the angiogram due to low image contrast. CONCLUSION: Free-breathing UTE-MRA using FE is feasible for simultaneous assessment of the pulmonary vasculature and nonvascular structures. Patient studies should investigate the clinical utility of free-breathing UTE-MRA for assessment of pulmonary emboli.


Assuntos
Óxido Ferroso-Férrico , Pulmão/irrigação sanguínea , Angiografia por Ressonância Magnética/métodos , Meglumina/análogos & derivados , Compostos Organometálicos , Adulto , Meios de Contraste , Estudos de Viabilidade , Feminino , Voluntários Saudáveis , Humanos , Aumento da Imagem/métodos , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional , Masculino , Estudos Prospectivos
6.
J Magn Reson Imaging ; 50(4): 1169-1181, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-30945385

RESUMO

BACKGROUND: Ultrashort echo time (UTE) proton MRI has gained popularity for assessing lung structure and function in pulmonary imaging; however, the development of rapid biomarker extraction and regional quantification has lagged behind due to labor-intensive lung segmentation. PURPOSE: To evaluate a deep learning (DL) approach for automated lung segmentation to extract image-based biomarkers from functional lung imaging using 3D radial UTE oxygen-enhanced (OE) MRI. STUDY TYPE: Retrospective study aimed to evaluate a technical development. POPULATION: Forty-five human subjects, including 16 healthy volunteers, 5 asthma, and 24 patients with cystic fibrosis. FIELD STRENGTH/SEQUENCE: 1.5T MRI, 3D radial UTE (TE = 0.08 msec) sequence. ASSESSMENT: Two 3D radial UTE volumes were acquired sequentially under normoxic (21% O2 ) and hyperoxic (100% O2 ) conditions. Automated segmentation of the lungs using 2D convolutional encoder-decoder based DL method, and the subsequent functional quantification via adaptive K-means were compared with the results obtained from the reference method, supervised region growing. STATISTICAL TESTS: Relative to the reference method, the performance of DL on volumetric quantification was assessed using Dice coefficient with 95% confidence interval (CI) for accuracy, two-sided Wilcoxon signed-rank test for computation time, and Bland-Altman analysis on the functional measure derived from the OE images. RESULTS: The DL method produced strong agreement with supervised region growing for the right (Dice: 0.97; 95% CI = [0.96, 0.97]; P < 0.001) and left lungs (Dice: 0.96; 95% CI = [0.96, 0.97]; P < 0.001). The DL method averaged 46 seconds to generate the automatic segmentations in contrast to 1.93 hours using the reference method (P < 0.001). Bland-Altman analysis showed nonsignificant intermethod differences of volumetric (P ≥ 0.12) and functional measurements (P ≥ 0.34) in the left and right lungs. DATA CONCLUSION: DL provides rapid, automated, and robust lung segmentation for quantification of regional lung function using UTE proton MRI. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2019;50:1169-1181.


Assuntos
Asma/diagnóstico por imagem , Fibrose Cística/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Pulmão/diagnóstico por imagem , Pulmão/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Adulto , Asma/fisiopatologia , Fibrose Cística/fisiopatologia , Feminino , Humanos , Imageamento Tridimensional/métodos , Masculino , Redes Neurais de Computação , Prótons , Estudos Retrospectivos
7.
Magn Reson Med ; 79(6): 2954-2967, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29023975

RESUMO

PURPOSE: To achieve motion robust high resolution 3D free-breathing pulmonary MRI utilizing a novel dynamic 3D image navigator derived directly from imaging data. METHODS: Five-minute free-breathing scans were acquired with a 3D ultrashort echo time (UTE) sequence with 1.25 mm isotropic resolution. From this data, dynamic 3D self-navigating images were reconstructed under locally low rank (LLR) constraints and used for motion compensation with one of two methods: a soft-gating technique to penalize the respiratory motion induced data inconsistency, and a respiratory motion-resolved technique to provide images of all respiratory motion states. RESULTS: Respiratory motion estimation derived from the proposed dynamic 3D self-navigator of 7.5 mm isotropic reconstruction resolution and a temporal resolution of 300 ms was successful for estimating complex respiratory motion patterns. This estimation improved image quality compared to respiratory belt and DC-based navigators. Respiratory motion compensation with soft-gating and respiratory motion-resolved techniques provided good image quality from highly undersampled data in volunteers and clinical patients. CONCLUSION: An optimized 3D UTE sequence combined with the proposed reconstruction methods can provide high-resolution motion robust pulmonary MRI. Feasibility was shown in patients who had irregular breathing patterns in which our approach could depict clinically relevant pulmonary pathologies. Magn Reson Med 79:2954-2967, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Assuntos
Imageamento Tridimensional , Pulmão/diagnóstico por imagem , Imageamento por Ressonância Magnética , Respiração , Técnicas de Imagem de Sincronização Respiratória/métodos , Adolescente , Adulto , Idoso , Algoritmos , Artefatos , Criança , Fibrose Cística/diagnóstico por imagem , Estudos de Viabilidade , Feminino , Voluntários Saudáveis , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Movimento (Física) , Nódulo Pulmonar Solitário/diagnóstico por imagem , Adulto Jovem
8.
J Magn Reson Imaging ; 47(5): 1287-1297, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29086454

RESUMO

BACKGROUND: A previous study demonstrated the feasibility of using 3D radial ultrashort echo time (UTE) oxygen-enhanced MRI (UTE OE-MRI) for functional imaging of healthy human lungs. The repeatability of quantitative measures from UTE OE-MRI needs to be established prior to its application in clinical research. PURPOSE: To evaluate repeatability of obstructive patterns in asthma and cystic fibrosis (CF) with UTE OE-MRI with isotropic spatial resolution and full chest coverage. STUDY TYPE: Volunteer and patient repeatability. POPULATION: Eighteen human subjects (five asthma, six CF, and seven normal subjects). FIELD STRENGTH/SEQUENCE: Respiratory-gated free-breathing 3D radial UTE (80 µs) sequence at 1.5T. ASSESSMENT: Two 3D radial UTE volumes were acquired sequentially under normoxic and hyperoxic conditions. A subset of subjects underwent repeat acquisitions on either the same day or ≤15 days apart. Asthma and CF subjects also underwent spirometry. A workflow including deformable registration and retrospective lung density correction was used to compute 3D isotropic percent signal enhancement (PSE) maps. Median PSE (MPSE) and ventilation defect percent (VDP) of the lung were measured from the PSE map. STATISTICAL TESTS: The relations between MPSE, VDP, and spirometric measures were assessed using Spearman correlations. The test-retest repeatability was evaluated using Bland-Altman analysis and intraclass correlation coefficients (ICC). RESULTS: Ventilation measures in normal subjects (MPSE = 8.0%, VDP = 3.3%) were significantly different from those in asthma (MPSE = 6.0%, P = 0.042; VDP = 21.7%, P = 0.018) and CF group (MPSE = 4.5%, P = 0.0006; VDP = 27.2%, P = 0.002). MPSE correlated significantly with forced expiratory lung volume in 1 second percent predicted (ρ = 0.72, P = 0.017). The ICC of the test-retest VDP and MPSE were both ≥0.90. In all subject groups, an anterior/posterior gradient was observed with higher MPSE and lower VDP in the posterior compared to anterior regions (P ≤ 0.0021 for all comparisons). DATA CONCLUSION: 3D radial UTE OE-MRI supports quantitative differentiation of diseased vs. healthy lungs using either whole lung VDP or MPSE with excellent test-retest repeatability. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2018;47:1287-1297.


Assuntos
Asma/diagnóstico por imagem , Fibrose Cística/diagnóstico por imagem , Imageamento Tridimensional , Pulmão/diagnóstico por imagem , Imageamento por Ressonância Magnética , Oxigênio/química , Ventilação Pulmonar , Adulto , Aprendizado Profundo , Feminino , Humanos , Hiperóxia/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Respiração , Testes de Função Respiratória , Espirometria , Fluxo de Trabalho , Adulto Jovem
9.
Emerg Radiol ; 25(5): 469-477, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29749576

RESUMO

PURPOSE: To compare patient outcomes following magnetic resonance angiography (MRA) versus computed tomographic angiography (CTA) ordered for suspected pulmonary embolism (PE). METHODS: In this IRB-approved, single-center, retrospective, case-control study, we reviewed the medical records of all patients evaluated for PE with MRA during a 5-year period along with age- and sex-matched controls evaluated with CTA. Only the first instance of PE evaluation during the study period was included. After application of our exclusion criteria to both study arms, the analysis included 1173 subjects. The primary endpoint was major adverse PE-related event (MAPE), which we defined as major bleeding, venous thromboembolism, or death during the 6 months following the index imaging test (MRA or CTA), obtained through medical record review. Logistic regression, chi-square test for independence, and Fisher's exact test were used with a p < 0.05 threshold. RESULTS: The overall 6-month MAPE rate following MRA (5.4%) was lower than following CTA (13.6%, p < 0.01). Amongst outpatients, the MAPE rate was lower for MRA (3.7%) than for CTA (8.0%, p = 0.01). Accounting for age, sex, referral source, BMI, and Wells' score, patients were less likely to suffer MAPE than those who underwent CTA, with an odds ratio of 0.44 [0.24, 0.80]. Technical success rate did not differ significantly between MRA (92.6%) and CTA (90.5%) groups (p = 0.41). CONCLUSION: Within the inherent limitations of a retrospective case-controlled analysis, we observed that the rate of MAPE was lower (more favorable) for patients following pulmonary MRA for the primary evaluation of suspected PE than following CTA.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Angiografia por Ressonância Magnética/métodos , Embolia Pulmonar/diagnóstico por imagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/sangue , Estudos de Casos e Controles , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco
10.
Eur Radiol ; 27(1): 32-40, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27137648

RESUMO

PURPOSE: To compare gadoxetic acid alone and combined gadoxetic acid/gadofosveset trisodium-enhanced liver MRI for detection of metastases and differentiation of metastases from haemangiomas. METHODS: Ninety-one patients underwent gadoxetic acid-enhanced liver MRI before and after additional injection of gadofosveset. First, two readers retrospectively identified metastases on gadoxetic acid alone enhanced delayed hepatobiliary phase T1-weighted images together with all other MR images (dynamic images, T2-weighted images, diffusion-weighted images). Second, readers assessed additional T1-weighted images obtained after administration of gadofosveset trisodium. For both interpretations, readers rated lesion conspicuity and confidence in differentiating metastases from haemangiomas. Results were compared using alternative free-response receiver-operating characteristic (AFROC) and conventional ROC methods. Histology and follow-up served as reference standard. RESULTS: There were 145 metastases and 16 haemangiomas. Both readers detected more metastases using combined gadoxetic acid/gadofosveset (reader 1 = 130; reader 2 = 124) compared to gadoxetic acid alone (reader 1 = 104; reader 2 = 103). Sensitivity of combined gadoxetic acid/gadofosveset (reader 1 = 90 %; reader 2 = 86 %) was higher than that of gadoxetic acid alone (reader 1 = 72 %; reader 2 = 71 %, both P < 0.01). AFROC-AUC was higher for the combined technique (0.92 vs. 0.86, P < 0.001). Sensitivity for correct differentiation of metastases from haemangiomas was higher for the combined technique (reader 1 = 98 %; reader 2 = 99 % vs. reader 1 = 86 %; reader 2 = 91 %, both P < 0.01). ROC-AUC was significantly higher for the combined technique (reader 1 = 1.00; reader 2 = 1.00 vs. reader 1 = 0.87; reader 2 = 0.92, both P < 0.01). CONCLUSION: Combined gadoxetic acid/gadofosveset-enhanced MRI improves detection and characterization of liver metastases compared to gadoxetic acid alone. KEY POINTS: • Combined gadoxetic acid and gadofosveset-enhanced liver MRI significantly improves detection of metastases. • The combined enhancement technique improves the accuracy to differentiate metastases from haemangiomas. • Prospective studies need to determine the clinical impact of the combined technique.


Assuntos
Gadolínio DTPA/farmacologia , Gadolínio/farmacologia , Neoplasias Hepáticas/diagnóstico , Imageamento por Ressonância Magnética/métodos , Compostos Organometálicos/farmacologia , Meios de Contraste/farmacologia , Feminino , Humanos , Neoplasias Hepáticas/secundário , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Curva ROC , Estudos Retrospectivos
11.
Am J Emerg Med ; 35(1): 146-149, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27836322

RESUMO

OBJECTIVE: Our aim was to validate the previously published claim of a positive relationship between low blood hemoglobin level (anemia) and pulmonary embolism (PE). METHODS: This was a retrospective study of patients undergoing cross-sectional imaging to evaluate for PE at an academic medical center. Patients were identified using billing records for charges attributed to either magnetic resonance angiography or computed tomography angiography of the chest from 2008 to 2013. The main outcome measure was mean hemoglobin levels among those with and without PE. Our reference standard for PE status included index imaging results and a 6-month clinical follow-up for the presence of interval venous thromboembolism, conducted via review of the electronic medical record. Secondarily, we performed a subgroup analysis of only those patients who were seen in the emergency department. Finally, we again compared mean hemoglobin levels when limiting our control population to an age- and sex-matched cohort of the included cases. RESULTS: There were 1294 potentially eligible patients identified, of whom 121 were excluded. Of the remaining 1173 patients, 921 had hemoglobin levels analyzed within 24 hours of their index scan and thus were included in the main analysis. Of those 921 patients, 107 (11.6%; 107/921) were positive for PE. We found no significant difference in mean hemoglobin level between those with and without PE regardless of the control group used (12.4 ± 2.1 g/dL and 12.3 ± 2.0 g/dL [P = .85], respectively). CONCLUSIONS: Our data demonstrated no relationship between anemia and PE.


Assuntos
Anemia/epidemiologia , Embolia Pulmonar/epidemiologia , Adulto , Anemia/metabolismo , Estudos de Casos e Controles , Angiografia por Tomografia Computadorizada , Serviço Hospitalar de Emergência , Feminino , Hemoglobinas/metabolismo , Humanos , Angiografia por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Embolia Pulmonar/diagnóstico por imagem , Estudos Retrospectivos , Fatores de Risco , Estados Unidos/epidemiologia , Trombose Venosa/epidemiologia
12.
Emerg Radiol ; 24(3): 273-280, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28116533

RESUMO

PURPOSE: The purpose of this study was to assess the ability of d-dimer testing to obviate the need for cross-sectional imaging for patients at "non-high risk" for pulmonary embolism (PE). METHODS: This is a retrospective study of emergency department patients at an academic medical center who underwent cross-sectional imaging (MRA or CTA) to evaluate for PE from 2008 to 2013. The primary outcome was the NPV of d-dimer testing when used in conjunction with clinical decision instruments (CDIs = Wells', Revised Geneva, and Simplified Revised Geneva Scores). The reference standard for PE status included image test results and a 6-month chart review follow-up for venous thromboembolism as a proxy for false negative imaging. Secondary analyses included ROC curves for each CDI and calculation of PE prevalence in each risk stratum. RESULTS: Of 459 patients, 41 (8.9%) had PE. None of the 76 patients (16.6%) with negative d-dimer results had PE. Thus, d-dimer testing had 100% sensitivity and NPV, and there were no differences in CDI performance. Similarly, when evaluated independently of d-dimer results, no CDI outperformed the others (areas under the ROC curves ranged 0.53-0.55). There was a significantly higher PE prevalence in the high versus "non-high risk" groups when stratified by the Wells' Score (p = 0.03). CONCLUSIONS: Negative d-dimer testing excluded PE in our retrospective cohort. Each CDI had similar NPVs, whether analyzed in conjunction with or independently of d-dimer results. Our results confirm that PE can be safely excluded in patients with "non-high risk" CDI scores and a negative d-dimer.


Assuntos
Produtos de Degradação da Fibrina e do Fibrinogênio/análise , Embolia Pulmonar/sangue , Embolia Pulmonar/diagnóstico por imagem , Adulto , Angiografia por Tomografia Computadorizada , Técnicas de Apoio para a Decisão , Serviço Hospitalar de Emergência , Feminino , Humanos , Angiografia por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
13.
Radiology ; 278(2): 413-21, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26422185

RESUMO

PURPOSE: To demonstrate the feasibility of free-breathing three-dimensional (3D) radial ultrashort echo time (UTE) magnetic resonance (MR) imaging in the simultaneous detection of pulmonary embolism (PE) and high-quality evaluation of lung parenchyma. MATERIALS AND METHODS: The institutional animal care committee approved this study. A total of 12 beagles underwent MR imaging and computed tomography (CT) before and after induction of PE with autologous clots. Breath-hold 3D MR angiography and free-breathing 3D radial UTE (1.0-mm isotropic spatial resolution; echo time, 0.08 msec) were performed at 3 T. Two blinded radiologists independently marked and graded all PEs on a four-point scale (1 = low confidence, 4 = absolutely certain) on MR angiographic and UTE images. Image quality of pulmonary arteries and lung parenchyma was scored on a four-point-scale (1 = poor, 4 = excellent). Locations and ratings of emboli were compared with reference standard CT images by using an alternative free-response receiver operating characteristic curve (AFROC) method. Areas under the curve and image quality ratings were compared by using the F test and the Wilcoxon signed-rank test. RESULTS: A total of 48 emboli were detected with CT. Both readers showed higher sensitivity for PE detection with UTE (83% and 79%) than with MR angiography (75% and 71%). The AFROC area under the curve was higher for UTE than for MR angiography (0.95 vs 0.89), with a significant difference in area under the curve of 0.06 (95% confidence interval: 0.01, 0.11; P = .018). UTE image quality exceeded that of MR angiography for subsegmental arteries (3.5 ± 0.7 vs 2.9 ± 0.5, P = .002) and lung parenchyma (3.8 ± 0.5 vs 2.2 ± 0.2, P < .001). The apparent signal-to-noise ratio in pulmonary arteries and lung parenchyma was significantly higher for UTE than for MR angiography (41.0 ± 5.2 vs 24.5 ± 6.2 [P < .001] and 10.2 ± 1.8 vs 3.5 ± 0.8 [P < .001], respectively). The apparent contrast-to-noise ratio between arteries and PEs was higher for UTE than for MR angiography (20.3 ± 5.2 vs 15.4 ± 6.7, P = .055). CONCLUSION: In a canine model, free-breathing 3D radial UTE performs better than breath-hold 3D MR angiography in the detection of PE and yields better image quality for visualization of small vessels and lung parenchyma. Free-breathing 3D radial UTE for detection of PE is feasible and warrants evaluation in human subjects.


Assuntos
Imageamento Tridimensional , Angiografia por Ressonância Magnética/métodos , Embolia Pulmonar/diagnóstico , Animais , Meios de Contraste , Modelos Animais de Doenças , Cães , Gadolínio , Compostos Organometálicos , Razão Sinal-Ruído , Tomografia Computadorizada por Raios X/métodos
14.
Radiology ; 278(1): 239-46, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26133050

RESUMO

PURPOSE: To investigate the utility of a free-breathing ultrashort echo time (UTE) sequence for the evaluation of small pulmonary nodules in oncology patients by using a hybrid positron emission tomography (PET)/magnetic resonance (MR) imaging system and to compare the nodule detection rate between UTE and a conventional three-dimensional gradient-recalled-echo (GRE) technique. MATERIALS AND METHODS: In this HIPAA-compliant, institutional review board-approved prospective study, 82 pulmonary nodules were identified in eight patients with extrathoracic malignancies. Patients underwent free-breathing UTE and dual-echo three-dimensional GRE imaging of the lungs in a hybrid PET/MR imaging unit immediately after clinical PET/computed tomography (CT). CT was considered the reference standard for nodule detection. Two reviewers identified nodules and obtained measurements on MR images. The McNemar test was used to evaluate differences in nodule detection rate between MR techniques, and interrater agreement was assessed by using Bland-Altman plots. RESULTS: Mean nodule diameter ± standard deviation was 6.2 mm ± 2.7 (range, 3-17 mm). The detection rate was higher for UTE imaging than for dual-echo GRE imaging for nodules of at least 4 mm (82% vs 34%, respectively; P < .001), with the largest difference in detection noted in the 4-8-mm nodule group (79% vs 21%, P < .001). UTE imaging displayed a higher detection rate than dual-echo GRE imaging for nodules without fluorodeoxyglucose avidity (68% vs 22%, respectively; P < .001). Interrater reliability of nodule detection with MR imaging was high (κ = 0.90 for UTE imaging and κ = 0.92 for dual-echo GRE imaging). CONCLUSION: A free-breathing UTE sequence has high sensitivity for the detection of small pulmonary nodules (4-8 mm) and outperformed a three-dimensional dual-echo GRE technique for the detection of small, non-fluorodeoxyglucose-avid nodules.


Assuntos
Neoplasias Pulmonares/diagnóstico , Imagem Multimodal , Nódulos Pulmonares Múltiplos/diagnóstico , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/secundário , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Nódulos Pulmonares Múltiplos/diagnóstico por imagem , Nódulos Pulmonares Múltiplos/secundário , Tomografia por Emissão de Pósitrons , Técnicas de Imagem de Sincronização Respiratória
15.
J Magn Reson Imaging ; 43(2): 295-315, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26218920

RESUMO

This review focuses on the state-of-the-art of the three major classes of gas contrast agents used in magnetic resonance imaging (MRI)-hyperpolarized (HP) gas, molecular oxygen, and fluorinated gas--and their application to clinical pulmonary research. During the past several years there has been accelerated development of pulmonary MRI. This has been driven in part by concerns regarding ionizing radiation using multidetector computed tomography (CT). However, MRI also offers capabilities for fast multispectral and functional imaging using gas agents that are not technically feasible with CT. Recent improvements in gradient performance and radial acquisition methods using ultrashort echo time (UTE) have contributed to advances in these functional pulmonary MRI techniques. The relative strengths and weaknesses of the main functional imaging methods and gas agents are compared and applications to measures of ventilation, diffusion, and gas exchange are presented. Functional lung MRI methods using these gas agents are improving our understanding of a wide range of chronic lung diseases, including chronic obstructive pulmonary disease, asthma, and cystic fibrosis in both adults and children.


Assuntos
Meios de Contraste , Gases , Aumento da Imagem/métodos , Pneumopatias/patologia , Pulmão/patologia , Imageamento por Ressonância Magnética , Humanos
16.
Magn Reson Med ; 73(2): 555-64, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24604452

RESUMO

PURPOSE: To assess the feasibility of spatial-temporal constrained reconstruction for accelerated regional lung perfusion using highly undersampled dynamic contrast-enhanced (DCE) three-dimensional (3D) radial MRI with ultrashort echo time (UTE). METHODS: A combined strategy was used to accelerate DCE MRI for 3D pulmonary perfusion with whole lung coverage. A highly undersampled 3D radial UTE MRI acquisition was combined with an iterative constrained reconstruction exploiting principal component analysis and wavelet soft-thresholding for dimensionality reduction in space and time. The performance of the method was evaluated using a 3D fractal-based DCE digital lung phantom. Simulated perfusion maps and contrast enhancement curves were compared with ground truth using the structural similarity index (SSIM) to determine robust threshold and regularization levels. Feasibility studies were then performed in a canine and a human subject with 3D radial UTE (TE=0.08 ms) acquisition to assess feasibility of mapping regional 3D perfusion. RESULTS: The method was able to accurately recover perfusion maps in the phantom with a nominal isotropic spatial resolution of 1.5 mm (SSIM of 0.949). The canine and human subject studies demonstrated feasibility for providing artifact-free perfusion maps in a simple 3D breath-held acquisition. CONCLUSION: The proposed method is promising for fast and flexible 3D pulmonary perfusion imaging. Magn Reson


Assuntos
Volume Sanguíneo/fisiologia , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Pulmão/fisiologia , Angiografia por Ressonância Magnética/métodos , Circulação Pulmonar/fisiologia , Algoritmos , Animais , Velocidade do Fluxo Sanguíneo/fisiologia , Cães , Estudos de Viabilidade , Humanos , Aumento da Imagem/métodos , Pulmão/irrigação sanguínea , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Análise Espaço-Temporal
17.
J Magn Reson Imaging ; 41(1): 52-9, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24357054

RESUMO

PURPOSE: To develop and demonstrate a breathheld 3D radial ultrashort echo time (UTE) acquisition to visualize co-registered lung perfusion and vascular structure. MATERIALS AND METHODS: Nine healthy dogs were scanned twice at 3 Tesla (T). Contrast-enhanced pulmonary perfusion scans were acquired with a temporally interleaved three-dimensional (3D) radial UTE (TE = 0.08 ms) sequence in a breathhold (1 s time frames over a 33 s breathhold). The 3D breathheld volume was reconstructed into time-resolved perfusion datasets, and a composite vascular structure dataset. For structural comparison, a 5 min respiratory-gated 3D radial UTE scan was acquired. Data were analyzed by quantitative metrics and radiologist scoring. RESULTS: Appropriate time-course of contrast was seen in all subjects. Right ventricle to aorta transit times were 7.4 ± 2.0 s. Relative lung enhancement was a factor of 8.4 ± 1.5. Radiologist scoring showed similarly excellent visualization of the pulmonary arteries to the subsegmental level in breathheld (94% of cases) and respiratory-gated (100% of cases) acquisitions (P = 0.33) despite the aggressive under sampling in the breathheld scan. Similarly, differentiation of lung tissue and airways was achieved by both acquisition methods. CONCLUSION: A time-resolved 3D radial UTE sequence for simultaneous imaging of pulmonary perfusion and co-registered vascular structure is feasible.


Assuntos
Imageamento Tridimensional/métodos , Pulmão/anatomia & histologia , Pulmão/irrigação sanguínea , Imageamento por Ressonância Magnética/métodos , Animais , Suspensão da Respiração , Meios de Contraste/administração & dosagem , Cães , Feminino , Aumento da Imagem , Masculino
18.
Magn Reson Med ; 72(3): 718-25, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24186810

RESUMO

PURPOSE: To develop and evaluate a free-breathing chemical-shift-encoded (CSE) spoiled gradient-recalled echo (SPGR) technique for whole-heart water-fat imaging at 3 Tesla (T). METHODS: We developed a three-dimensional (3D) multi-echo SPGR pulse sequence with electrocardiographic gating and navigator echoes and evaluated its performance at 3T in healthy volunteers (N = 6) and patients (N = 20). CSE-SPGR, 3D SPGR, and 3D balanced-SSFP with chemical fat saturation were compared in six healthy subjects with images evaluated for overall image quality, level of residual artifacts, and quality of fat suppression. A similar scoring system was used for the patient datasets. RESULTS: Images of diagnostic quality were acquired in all but one subject. CSE-SPGR performed similarly to SPGR with fat saturation, although it provided a more uniform fat suppression over the whole field of view. Balanced-SSFP performed worse than SPGR-based methods. In patients, CSE-SPGR produced excellent fat suppression near metal. Overall image quality was either good (7/20) or excellent (12/20) in all but one patient. There were significant artifacts in 5/20 clinical cases. CONCLUSION: CSE-SPGR is a promising technique for whole-heart water-fat imaging during free-breathing. The robust fat suppression in the water-only image could improve assessment of complex morphology at 3T and in the presence of off-resonance, with additional information contained in the fat-only image.


Assuntos
Doenças Cardiovasculares/diagnóstico , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Tecido Adiposo , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Artefatos , Técnicas de Imagem de Sincronização Cardíaca , Meios de Contraste , Feminino , Voluntários Saudáveis , Humanos , Imageamento Tridimensional/métodos , Masculino , Meglumina/análogos & derivados , Pessoa de Meia-Idade , Compostos Organometálicos , Estudos Prospectivos , Água
19.
Magn Reson Med ; 71(2): 783-9, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23441013

RESUMO

PURPOSE: To demonstrate the feasibility of direct virtual coil (DVC) in the setting of 4D dynamic imaging used in multiple clinical applications. THEORY AND METHODS: Three dynamic imaging applications were chosen: pulmonary perfusion, liver perfusion, and peripheral MR angiography (MRA), with 18, 11, and 10 subjects, respectively. After view-sharing, the k-space data were reconstructed twice: once with channel-by-channel (CBC) followed by sum-of-squares coil combination and once with DVC. Images reconstructed using CBC and DVC were compared and scored based on overall image quality by two experienced radiologists using a five-point scale. RESULTS: The CBC and DVC showed similar image quality in image domain. Time course measurements also showed good agreement in the temporal domain. CBC and DVC images were scored as equivalent for all pulmonary perfusion cases, all liver perfusion cases, and four of the 10 peripheral MRA cases. For the remaining six peripheral MRA cases, DVC were scored as slightly better (not clinically significant) than the CBC images by Radiologist A and as equivalent by Radiologist B. CONCLUSION: For dynamic contrast-enhanced MR applications, it is clinically feasible to reduce image reconstruction time while maintaining image quality and time course measurement using the DVC technique.


Assuntos
Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Armazenamento e Recuperação da Informação/métodos , Angiografia por Ressonância Magnética/métodos , Interface Usuário-Computador , Algoritmos , Estudos de Viabilidade , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
20.
NMR Biomed ; 27(12): 1535-41, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24984695

RESUMO

The purpose of this work was to use 3D radial ultrashort echo time (UTE) MRI to perform whole-lung oxygen-enhanced (OE) imaging in humans. Eight healthy human subjects underwent two 3D radial UTE MRI acquisitions (TE = 0.08 ms): one while breathing 21% O2 and the other while breathing 100% O2. Scans were each performed over 5 min of free breathing, using prospective respiratory gating. For comparison purposes, conventional echo time (TE = 2.1 ms) images were acquired simultaneously during each acquisition using a radial " outward-inward" k-space trajectory. 3D percent OE maps were generated from these images. 3D OE maps showing lung signal enhancement were generated successfully in seven subjects (technical failure in one subject). Mean percent signal enhancement was 6.6% ± 1.8%, near the value predicted by theory of 6.3%. No significant enhancement was seen using the conventional echo time data, confirming the importance of UTE for this acquisition strategy. 3D radial UTE MRI shows promise as a method for OE MRI that enables whole-lung coverage and isotropic spatial resolution, in comparison to existing 2D OE methods, which rely on a less time-efficient inversion recovery pulse sequence. These qualities may help OE MRI become a viable low-cost method for 3D imaging of lung function in human subjects.


Assuntos
Imageamento Tridimensional , Pulmão/fisiologia , Imageamento por Ressonância Magnética/métodos , Oxigênio , Adulto , Feminino , Saúde , Humanos , Masculino , Pessoa de Meia-Idade , Processamento de Sinais Assistido por Computador , Fatores de Tempo , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA