Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
J Cardiovasc Electrophysiol ; 34(3): 627-637, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36651347

RESUMO

INTRODUCTION: Diagnosis of outflow tract ventricular arrhythmia (OTVA) localization by an electrocardiographic complex is key to successful catheter ablation for OTVA. However, diagnosing the origin of OTVA with a precordial transition in lead V3 (V3TZ) is challenging. This study aimed to create the best practical electrocardiogram algorithm to differentiate the left ventricular outflow tract (LVOT) from the right ventricular outflow tract (RVOT) of OTVA origin with V3TZ using machine learning. METHODS: Of 498 consecutive patients undergoing catheter ablation for OTVA, we included 104 patients who underwent ablation for OTVA with V3TZ and identified the origin of LVOT (n = 62) and RVOT (n = 42) from the results. We analyzed the standard 12-lead electrocardiogram preoperatively and measured 128 elements in each case. The study population was randomly divided into training group (70%) and testing group (30%), and decision tree analysis was performed using the measured elements as features. The performance of the algorithm created in the training group was verified in the testing group. RESULTS: Four measurements were identified as important features: the aVF/II R-wave ratio, the V2S/V3R index, the QRS amplitude in lead V3, and the R-wave deflection slope in lead V3. Among them, the aVF/II R-wave ratio and the V2S/V3R index had a particularly strong influence on the algorithm. The performance of this algorithm was extremely high, with an accuracy of 94.4%, precision of 91.5%, recall of 100%, and an F1-score of 0.96. CONCLUSIONS: The novel algorithm created using machine learning is useful in diagnosing the origin of OTVA with V3TZ.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Humanos , Algoritmos , Arritmias Cardíacas , Eletrocardiografia/métodos , Ventrículos do Coração , Aprendizado de Máquina
2.
J Cardiovasc Electrophysiol ; 33(7): 1515-1528, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35598302

RESUMO

INTRODUCTION: Reactive atrial-based antitachycardia pacing (rATP) in patients with cardiac implantable electronic devices (CIEDs) suppresses the progression of atrial fibrillation (AF) to the persistent form. However, the clinical factors associated with successful reactive atrial-based antitachycardia pacing (rATP) treatment are unknown. This study aimed to examine the predictors of high rATP efficacy in patients with CIEDs. METHODS: The data of 101,325 rATP-treated atrial tachyarrhythmia (AT/AF) episodes in 51 patients, obtained through remote monitoring and device interrogation, were analyzed. The study population was divided into the high and low efficacy groups based on the overall median success rate of rATP. Clinical characteristics were compared between the two groups. RESULTS: During a follow-up period of 28.6 ± 8.6 months, the median success rate was 43.7% (31.5%-64.9%). The prevalence of a history of catheter ablation of AF was significantly higher in the high efficacy group than in the low efficacy group (73.0% vs. 44.0%, p = .048) and was the only independent predictor of high rATP efficacy (odds ratio, 3.45; p = .038). The rATP success rate in patients with (n = 30) and without (n = 21) a history of catheter ablation was 53.9% (40.0%-67.5%) and 36.4% (22.2%-47.7%), respectively (p = .012). The effect of rATP after ablation was more pronounced in patients with long cycle length episodes (≥75% of AT/AF sequences having a cycle length of 200-449 ms) (67.3% [46.0%-73.6%] vs. 30.6% [18.1%-60.3%], p = .027). The high efficacy group had a significantly lower incidence of AT/AF lasting ≥1, ≥7, and ≥30 days than the low efficacy group. CONCLUSION: rATP combined with catheter ablation therapy is effective in suppressing AT/AF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Eletrônica , Átrios do Coração/cirurgia , Humanos , Resultado do Tratamento
3.
Heart Vessels ; 37(5): 840-853, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34708268

RESUMO

Focal activation is believed to be an atrial fibrillation (AF) driver; however, little is known about whether all focal activations are necessary for AF persistence. The purpose of this study was to assess the electrical nature of focal activation and identify high-priority focal activations using a novel mapping system (CARTOFINDER). Thirty-five patients with persistent AF who underwent catheter ablation were assessed. Cycle length (CL) and CL standard deviation (CLSD) on unipolar recordings and voltage amplitude and electrogram morphologies on bipolar recordings were evaluated at all points of interest. The most frequent CL at each mapping site was defined as the dominant CL. We identified dominant focal activations (DFAs) that had a shorter dominant CL on the integrated CARTOFINDER map. The effect of elimination of DFAs on AF maintenance was assessed by the composite endpoint (termination to sinus rhythm, organization of the rhythm to atrial tachycardia, and AF CL slowing). In all, 450 focal activations were identified among 10,868 points, and 50.4% of focal activations were DFAs. Focal activations showed relatively long CL and regularity with short CLSD. Most focal activations showed an isoelectric baseline and were located outside of the fractionated electrogram area. Both DFAs and non-DFAs were typically observed in the normal voltage range. Elimination of DFAs was achieved in 19 (54.3%) patients, with a remarkable impact on AF maintenance (68.4% vs. 25.0%, p = 0.018). In conclusion, DFAs may play an important role in AF maintenance and could be an attractive therapeutic target for AF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Taquicardia Supraventricular , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Técnicas Eletrofisiológicas Cardíacas , Humanos , Taquicardia Supraventricular/cirurgia , Resultado do Tratamento
4.
Ann Noninvasive Electrocardiol ; 27(5): e12991, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35802829

RESUMO

BACKGROUND: The current study aimed to evaluate changes in electrical depolarization and repolarization parameters after His-bundle pacing (HBP) compared with right ventricular pacing (RVP) and its association with ventricular arrhythmia (VA). METHODS: Forty-one patients (13 with HBP, 14 with RVP, and 14 controls [AAI mode]) were evaluated. After continuous pacing algorithm, QRS duration, QT interval, QTc, JT interval, T-peak to T-end (Tpe), and Tpe/QT ratio were measured on electrocardiography at baseline and 1 week, 1 month, and 6 months postoperatively. We investigated VA occurrence and adverse events after implantation. RESULTS: At 6 months, QRS duration was significantly shorter in the HBP (121.6 ± 15.6 ms) than in the RVP (150.1 ± 14.9 ms) group. The QT intervals were lower in the HBP (424.0 ± 40.9 ms) and control (405.9 ± 23.0 ms) groups than in the RVP (453.0 ± 40.2 ms) group. The Tpe and Tpe/QT ratios at 6 months differed significantly between the HBP and RVP groups (Tpe, 69.8 ± 19.7 ms vs 87.4 ± 11.9 ms and Tpe/QT, 0.16 ± 0.03 vs 0.19 ± 0.02, respectively). The Tpe and Tpe/QT ratios were similarly shortened in the HBP and control groups. VA occurred less frequently in the HBP (15%) and control (7.1%) groups than in the RVP (50%) group (p = 0.020). The non-RVP group showed significantly lower rates of VA and major adverse events than the RVP group. Patients with VA demonstrated significantly longer QRS duration, QT interval, Tpe, and Tpe/QT at 6 months than those without VA. CONCLUSION: HBP showed better depolarization and repolarization stability than RVP.


Assuntos
Fascículo Atrioventricular , Estimulação Cardíaca Artificial , Arritmias Cardíacas , Eletrocardiografia , Frequência Cardíaca , Ventrículos do Coração , Humanos , Resultado do Tratamento
5.
Int Heart J ; 63(3): 633-638, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35650163

RESUMO

We report the usefulness of novel automated anti-tachycardia pacing (ATP) for ventricular tachycardia (VT) termination evaluated in an electrophysiology study. This intrinsic, automated ATP with an implanted cardiac resynchronization therapy-defibrillator successfully terminated the sustained VT, which had not been suppressed by repetitive burst pacing from the electrode catheter. The reproduction of programed pacing of the automated ATP by a right ventricular electrode catheter was effective in terminating VT, and this termination was absolute and reproducible. Further detailed assessment in an electrophysiology study could highlight the algorithm of the automated ATP and its possible benefit in terminating the reentrant VT.


Assuntos
Terapia de Ressincronização Cardíaca , Taquicardia Ventricular , Trifosfato de Adenosina , Algoritmos , Morte , Eletrofisiologia , Humanos , Taquicardia Ventricular/terapia
6.
Circ J ; 85(8): 1283-1293, 2021 07 21.
Artigo em Inglês | MEDLINE | ID: mdl-33692251

RESUMO

BACKGROUND: Catheter ablation (CA) is effective for recurrent episodes of ventricular fibrillation (VF) in Brugada syndrome (BrS). VF development in BrS is associated with several electrocardiogram (ECG) abnormalities. This study investigated changes in ECG parameters in high-risk BrS patients who underwent epicardial CA.Methods and Results:In all, 27 BrS patients were implanted with an implantable cardioverter-defibrillator (ICD). Patients were divided into 2 groups: (1) an ablation group (n=11) that underwent epicardial CA because of VF recurrence; and (2) a primary prevention (PP) group (n=16) with ICD implantation only. ECG parameters were evaluated before and 12 months after CA and compared with ECG parameters in the PP group. The T wave peak-to-end interval was significantly longer and the number of abnormal spikes in leads V1-V3 at the second, third, and fourth intercostal spaces was greater in the ablation than PP group. After ablation, ST levels and the sum of abnormal spikes in leads V1-V3 were significantly decreased. The mean (±SD) number of ICD shocks decreased markedly during a mean follow-up period of 42.0 months (from 3.8±3.7 to 0.2±0.4/year). Four patients had an ICD shock following the ablation procedure. Greater reductions in ST-segment elevation and abnormal spikes were observed in the group without than with VF recurrence. CONCLUSIONS: Improvements in surface ECG parameters appear to be associated with successful ablation in high-risk BrS patients.


Assuntos
Síndrome de Brugada , Ablação por Cateter , Síndrome de Brugada/cirurgia , Desfibriladores Implantáveis , Eletrocardiografia , Humanos , Fibrilação Ventricular/cirurgia
7.
Heart Vessels ; 36(7): 986-998, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33495858

RESUMO

Cardiac resynchronization therapy (CRT) improves functional mitral regurgitation (MR); however, the mechanism and differences in acute and late improvement in MR are unclear. We aimed to evaluate the factors associated with the acute and late MR improvements and the prognosis of MR improvement after CRT. This retrospective study included 121 patients who underwent CRT implantation with full echocardiography assessment at baseline, 1 week, and 6 months after implantation. MR severity was classified into five grades (0: none to 4: severe). Two-dimensional speckle-tracking echocardiography with radial strain was used to assess dyssynchrony, and the time difference between the lateral and inferior segments at papillary muscle levels (TDlate-inf) was calculated. The MR improved 1 week and 6 months after CRT in 40 (33%) and 45 (37%) patients, respectively. On multivariate analyses, TDlate-inf (baseline-1 week) and SPWMD were independently associated with acute MR improvement. The %reduction in left ventricular end-systolic volume (LVESV) (baseline-6 months) and TDlate-inf (baseline-1 week) were independently correlated with late MR improvement. The patients with pre-MR grades 2-4 and improved MR after CRT showed significantly better prognosis in heart failure hospitalization. Cutoff values of ≥ 19.5 ms of the reduction of TDlate-inf and ≥ 30.8% of the %reduction of LVESV were significantly associated with the decrease in heart failure hospitalization. The improved interpapillary muscle activation time delay and volume reduction after CRT were associated with acute and late MR improvements. There may be different time course of recovery and distinct causes for late MR improvement.


Assuntos
Terapia de Ressincronização Cardíaca/métodos , Ventrículos do Coração/diagnóstico por imagem , Insuficiência da Valva Mitral/terapia , Marca-Passo Artificial , Músculos Papilares/fisiopatologia , Remodelação Ventricular/fisiologia , Doença Aguda , Idoso , Progressão da Doença , Ecocardiografia , Feminino , Seguimentos , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/fisiopatologia , Músculos Papilares/diagnóstico por imagem , Prognóstico , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
8.
J Interv Card Electrophysiol ; 67(2): 303-317, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37354370

RESUMO

BACKGROUND: Real-time phase mapping (ExTRa™) is useful in determining the strategy of catheter ablation for non-paroxysmal atrial fibrillation (AF). This study aimed to investigate the features of drivers of AF associated with its termination during ablation. METHODS: Thirty-six patients who underwent catheter ablation for non-paroxysmal AF using online real-time phase mapping (ExTRa™) were enrolled. A significant AF driver was defined as an area with a non-passively activated ratio of ≥ 50% on mapping analysis in the left atrium (LA). All drivers were simultaneously evaluated using a low-voltage area, complex fractionated atrial electrogram (CFAE), and rotational activity by unipolar electrogram analysis. The electrical characteristics of drivers were compared between patients with and without AF termination during the procedure. RESULTS: Twelve patients achieved AF termination during the procedure. The total number of drivers detected on the mapping was significantly lower (4.4 ± 1.6 vs. 7.4 ± 3.8, p = 0.007), and the drivers were more concentrated in limited LA regions (2.8 ± 0.9 vs. 3.9 ± 1.4, p = 0.009) in the termination group than in the non-termination group. The presence of drivers 2-6 with limited (≤ 3) LA regions showed a tenfold increase in the likelihood of AF termination, with 83% specificity and 67% sensitivity. Among 231 AF drivers, the drivers related to termination exhibited a greater overlap of CFAE (56.8 ± 34.1% vs. 39.5 ± 30.4%, p = 0.004) than the non-related drivers. The termination group showed a trend toward a lower recurrence rate after ablation (p = 0.163). CONCLUSIONS: Rotors responsible for AF maintenance may be characterized in cases with concentrated regions and fewer drivers on mapping.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/cirurgia , Átrios do Coração/cirurgia , Ablação por Cateter/métodos , Técnicas Eletrofisiológicas Cardíacas/métodos , Resultado do Tratamento
9.
J Interv Card Electrophysiol ; 65(1): 239-249, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35739437

RESUMO

BACKGROUND: The adaptive cardiac resynchronization therapy (aCRT) algorithm automatically produces synchronized left ventricular pacing (sLVP) with intrinsic atrioventricular conduction to improve clinical outcomes. However, relationship between sLVP percentage and risk for ventricular tachyarrhythmia (VT/VF) remains unclear. This study aimed to evaluate the clinical impact of sLVP rate on VT/VF occurrence. METHODS: In total, 1,419 device interrogation data from 42 consecutive patients who underwent new aCRT device implantation were retrospectively analyzed. The primary endpoint was the first time VT/VF episode after aCRT device implantation. RESULTS: During a median follow-up of 34 months, 15 patients had VT/VF episodes. Patients were divided into a high sLVP (the average sLVP percentage of ≥ 51.5%, n = 27) or low sLVP group (< 51.5%, n = 15). The high sLVP group had a significantly lower VT/VF incidence (22% vs. 60%; p = 0.014) and an independent predictor for VT/VF occurrence on multivariate analysis (hazard ratio 0.21; p = 0.007). LV ejection fraction improvements after 6 months (12.3 ± 8.7% vs. 2.8 ± 10.3%; p = 0.004) and 12 months (13.8 ± 9.3% vs. 6.2 ± 11.1%; p = 0.030) were significantly greater in the high sLVP group than in the low sLVP group. Age, PR interval, and left atrial diameter were significantly associated with the sLVP rate after aCRT. CONCLUSIONS: Patients with high sLVP percentage after aCRT had lower long-term risk of VT/VF incidence with a favorable response to CRT. A synchronized pacing algorithm using intrinsic conduction may prevent malignant arrhythmias, as well as recover cardiac functions.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Taquicardia Ventricular , Insuficiência Cardíaca/prevenção & controle , Humanos , Estudos Retrospectivos , Taquicardia Ventricular/prevenção & controle , Resultado do Tratamento
10.
JACC Clin Electrophysiol ; 8(6): 735-748, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35738850

RESUMO

BACKGROUND: Catheter ablation for ventricular tachycardia (VT) is associated with perioperative thromboembolic risk. However, the strategy for postprocedural management remains unknown. OBJECTIVES: The aim of this study was to evaluate the prothrombotic response after VT ablation in various coagulation biomarkers in patients with and without the administration of oral anticoagulation (OAC). METHODS: Data from 112 patients (58 with uninterrupted OAC and 54 without) with structural heart disease who underwent endocardial VT ablation were retrospectively analyzed. We also included 41 patients who underwent ablation for premature ventricular contraction from the right ventricle and 13 patients who underwent electrophysiology study (the control group). Blood samples of coagulation markers were collected before and 3 days after the procedure in all patients. RESULTS: The percentage of D-dimer levels ≤1.0 µg/mL at baseline was lower in the VT ablation groups (76% and 50% in the OAC and non-OAC groups, respectively) than in the other groups (100%). After 3 days, the percentage remained at 67% in the OAC group; however, the non-OAC VT group demonstrated a remarkable decrease of 20%. Similarly, fibrin monomer complex, thrombin antithrombin, and prothrombin fragment 1+2 levels were well suppressed in the control, premature ventricular contraction, and OAC groups. However, the non-OAC group demonstrated increased coagulation markers both before and after 3 days. Multivariate analysis demonstrated that OAC administration and normal coagulation markers at baseline were independent predictors of stable coagulation status after ablation. CONCLUSIONS: The coagulation cascade was significantly activated in patients undergoing VT ablation. Uninterrupted OAC administration suppressed the coagulation response, which might be associated with a reduction in perioperative prothrombotic risk.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Complexos Ventriculares Prematuros , Anticoagulantes/efeitos adversos , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Humanos , Estudos Retrospectivos , Taquicardia Ventricular/cirurgia , Complexos Ventriculares Prematuros/cirurgia
11.
Am J Cardiol ; 155: 52-63, 2021 09 15.
Artigo em Inglês | MEDLINE | ID: mdl-34281670

RESUMO

The risk for developing left atrial (LA) thrombi after initial catheter ablation for atrial fibrillation (AF) and requirements for imaging evaluation for thrombi screening at repeat ablation is unclear. This study aimed to assess the occurrence of thrombus development and frequency of any imaging study evaluating thrombus formation during repeat ablation for AF. Of 2,066 patients undergoing initial catheter ablation for AF with uninterrupted oral anticoagulation, 615 patients underwent repeat ablation after 258.0 (105.0-882.0) days. We investigated the factors associated with safety outcomes and requirements for thrombus screening. All patients underwent at least one imaging examination to screen for thrombi in the initial session; however, the examination rate decreased to 476 patients (77%) before the repeat session. The frequency of imaging evaluations was 5.0%, 11%, 21%, 84%, and 91% for transesophageal echocardiography and 18%, 33%, 49%, 98%, and 99% for any imaging modality at repeat ablation performed ≤60 days, ≤90 days, ≤180 days, >180 days, and >1 year after the initial session, respectively. Three patients (0.5%) developed LA thrombi at repeat ablation due to identifiable causes, and no patients experienced thromboembolic events when no imaging evaluation was performed. Multivariate analysis revealed that repeat ablation performed after >180 days, non-paroxysmal atrial arrhythmias, and lower left ventricular ejection fraction were predictors of thrombus development and severe spontaneous echocardiography contrast. In conclusion, the risk for thrombus development at repeat ablation for AF was low. There needs to be a risk stratification of the imaging screening for thrombi at repeat ablation.


Assuntos
Fibrilação Atrial/complicações , Ablação por Cateter , Ecocardiografia Transesofagiana/métodos , Vigilância da População/métodos , Trombose/epidemiologia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Feminino , Seguimentos , Átrios do Coração , Cardiopatias/diagnóstico , Cardiopatias/epidemiologia , Cardiopatias/etiologia , Humanos , Incidência , Japão/epidemiologia , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Retrospectivos , Trombose/diagnóstico , Trombose/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA