1.
Magn Reson Med ; 92(3): 1277-1289, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38469893

RESUMO

PURPOSE: Ultrahigh field (≥7 T) MRI is at the cutting edge of medical imaging, enabling enhanced spatial and spectral resolution as well as enhanced susceptibility contrast. However, transmit ( B 1 + $$ {\mathrm{B}}_1^{+} $$ ) field inhomogeneity due to standing wave effects caused by the shortened RF wavelengths at 7 T is still a challenge to overcome. Novel hardware methods such as dielectric pads have been shown to improve the B 1 + $$ {\mathrm{B}}_1^{+} $$ field inhomogeneity but are currently limited in their corrective effect by the range of high-permittivity materials available and have a fixed shelf life. In this work, an optimized metasurface design is presented that demonstrates in vivo enhancement of the B 1 + $$ {\mathrm{B}}_1^{+} $$ field. METHODS: A prototype metasurface was optimized by an empirical capacitor sweep and by varying the period size. Phantom temperature experiments were performed to evaluate potential metasurface heating effects during scanning. Lastly, in vivo gradient echo images and B 1 + $$ {\mathrm{B}}_1^{+} $$ maps were acquired on five healthy subjects on a 7 T system. Dielectric pads were also used as a comparison throughout the work as a standard comparison. RESULTS: The metasurfaces presented here enhanced the average relative SNR of the gradient echo images by a factor of 2.26 compared to the dielectric pads factor of 1.61. Average B 1 + $$ {\mathrm{B}}_1^{+} $$ values reflected a similar enhancement of 27.6% with the metasurfaces present versus 8.9% with the dielectric pads. CONCLUSION: The results demonstrate that metasurfaces provide superior performance to dielectric padding as shown by B 1 + $$ {\mathrm{B}}_1^{+} $$ maps reflecting their direct effects and resulting enhancements in image SNR at 7 T.


Assuntos
Desenho de Equipamento , Imageamento por Ressonância Magnética , Imagens de Fantasmas , Imageamento por Ressonância Magnética/instrumentação , Humanos , Perna (Membro)/diagnóstico por imagem , Adulto , Aumento da Imagem/métodos , Feminino , Masculino , Processamento de Imagem Assistida por Computador/métodos , Algoritmos , Razão Sinal-Ruído
2.
NMR Biomed ; : e5158, 2024 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-38584133

RESUMO

PURPOSE: In vivo quantification of lactate has numerous applications in studying the pathology of both cerebral and musculoskeletal systems. Due to its low concentration (~0.5-1 mM), and overlap with lipid signals, traditional 1H MR spectra acquired in vivo using a small voxel and short echo time often result in an inadequate signal to detect and resolve the lactate peak, especially in healthy human volunteers. METHODS: In this study, using a semi-LASER acquisition with long echo time (TE = 288 ms) and large voxel size (80 × 70 × 20 mm3), we clearly visualize the combined signal of lactate and threonine. Therefore, we call the signal at 1.33 ppm Lac+ and quantify Lac+ concentration from water suppressed spectra in healthy human brains in vivo. Four participants (22-37 years old; mean age = 28 ± 5.4; three male, one female) were scanned on four separate days, and on each day four measurements were taken. Intra-day values are calculated for each participant by comparing the four measurements on a single day. Inter-day values were calculated using the mean intra-day measurements. RESULTS: The mean intra-participant Lac+ concentration, standard deviation (SD), and coefficient of variation (CV) ranged from 0.49 to 0.61 mM, 0.02 to 0.07 mM, and 4% to 13%, respectively, across four volunteers. The inter-participant Lac+ concentration, SD, and CV was 0.53 mM, ±0.06 mM, and 11%. CONCLUSION: Repeatability is shown in Lac+ measurement in healthy human brain using a long echo time semi-LASER sequence with a large voxel in about 3.5 min at 3 T.

3.
Int J Neuropsychopharmacol ; 27(2)2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38315678

RESUMO

BACKGROUND: Previous preclinical and human studies have shown that a high-fat ketogenic diet and ketone supplements (KS) are efficacious in reducing alcohol craving, alcohol consumption, and signs of alcohol withdrawal. However, the effects of KS on alcohol sensitivity are unknown. METHODS: In this single-blind, cross-over study, 10 healthy participants (3 females) were administered a single, oral dose of a KS (25 g of ketones from D-ß-hydroxybutyric acid and R-1,3-butanediol) or placebo 30 minutes before an oral alcohol dose (0.25 g/kg for women; 0.31 g/kg for men). Assessments of breath alcohol concentration and blood alcohol levels (BAL) and responses on the Drug Effect Questionnaire were repeatedly obtained over 180 minutes after alcohol consumption. In a parallel preclinical study, 8 Wistar rats (4 females) received an oral gavage of KS (0.42 g ketones/kg), water, or the sweetener allulose (0.58 g/kg) followed 15 minutes later by an oral alcohol dose (0.8 g/kg). BAL was monitored for 240 minutes after alcohol exposure. RESULTS: In humans, the intake of KS before alcohol significantly blunted breath alcohol concentration and BAL, reduced ratings of alcohol liking and wanting more, and increased disliking for alcohol. In rats, KS reduced BAL more than either allulose or water. CONCLUSION: KS altered physiological and subjective responses to alcohol in both humans and rats, and the effects were likely not mediated by the sweetener allulose present in the KS drink. Therefore, KS could potentially reduce the intoxicating effects of alcohol.


Assuntos
Alcoolismo , Síndrome de Abstinência a Substâncias , Masculino , Humanos , Ratos , Feminino , Animais , Estudos Cross-Over , Cetonas/farmacologia , Voluntários Saudáveis , Método Simples-Cego , Ratos Wistar , Etanol/farmacologia , Edulcorantes , Concentração Alcoólica no Sangue , Suplementos Nutricionais , Água
4.
Hum Brain Mapp ; 44(2): 549-558, 2023 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-36173151

RESUMO

Temporal lobe epilepsy (TLE) is one of the most common subtypes of focal epilepsy, with mesial temporal sclerosis (MTS) being a common radiological and histopathological finding. Accurate identification of MTS during presurgical evaluation confers an increased chance of good surgical outcome. Here we propose the use of glutamate-weighted chemical exchange saturation transfer (GluCEST) magnetic resonance imaging (MRI) at 7 Tesla for mapping hippocampal glutamate distribution in epilepsy, allowing to differentiate lesional from non-lesional mesial TLE. We demonstrate that a directional asymmetry index, which quantifies the relative difference between GluCEST contrast in hippocampi ipsilateral and contralateral to the seizure onset zone, can differentiate between sclerotic and non-sclerotic hippocampi, even in instances where traditional presurgical MRI assessments did not provide evidence of sclerosis. Overall, our results suggest that hippocampal glutamate mapping through GluCEST imaging is a valuable addition to the presurgical epilepsy evaluation toolbox.


Assuntos
Epilepsia do Lobo Temporal , Epilepsia , Humanos , Epilepsia do Lobo Temporal/diagnóstico por imagem , Epilepsia do Lobo Temporal/cirurgia , Epilepsia do Lobo Temporal/patologia , Ácido Glutâmico , Hipocampo/diagnóstico por imagem , Hipocampo/patologia , Imageamento por Ressonância Magnética/métodos , Epilepsia/patologia , Esclerose/diagnóstico por imagem , Esclerose/patologia
5.
Magn Reson Med ; 89(6): 2295-2304, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36744726

RESUMO

PURPOSE: Nuclear Overhauser effect (NOE) is based on dipolar cross-relaxation mechanism that enables the indirect detection of aliphatic protons via the water proton signal. This work focuses on determining the reproducibility of NOE magnetization transfer ratio (NOEMTR ) and isolated or relayed NOE (rNOE) contributions to the NOE MRI of the healthy human brain at 7 Tesla (T). METHODS: We optimized the B 1 + $$ {\mathrm{B}}_1^{+} $$ amplitude and length of the saturation pulse by acquiring NOE images with different B 1 + $$ {\mathrm{B}}_1^{+} $$ values with multiple saturation lengths. Repeated NOE MRI measurements were made on five healthy volunteers by using optimized saturation pulse parameters including correction of B0 and B 1 + $$ {\mathrm{B}}_1^{+} $$ inhomogeneities. To isolate the individual contributions from z-spectra, we have fit the NOE z-spectra using multiple Lorentzians and calculated the total contribution from each pool contributing to the overall NOEMTR contrast. RESULTS: We found that a saturation amplitude of 0.72 µT and a length of 3 s provided the highest contrast. We found that the mean NOEMTR value in gray matter (GM) was 26%, and in white matter (WM) was 33.3% across the 3D slab of the brain. The mean rNOE contributions from GM and WM values were 8.9% and 9.6%, which were ∼10% of the corresponding total NOEMTR signal. The intersubject coefficient of variations (CoVs) of NOEMTR from GM and WM were 4.5% and 6.5%, respectively, whereas the CoVs of rNOE were 4.8% and 5.6%, respectively. The intrasubject CoVs of the NOEMTR range was 2.1%-4.2%, and rNOE range was 2.9%-10.5%. CONCLUSION: This work has demonstrated an excellent reproducibility of both inter- and intrasubject NOEMTR and rNOE metrics in healthy human brains at 7 T.


Assuntos
Algoritmos , Neoplasias Encefálicas , Humanos , Reprodutibilidade dos Testes , Interpretação de Imagem Assistida por Computador/métodos , Encéfalo/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Prótons
6.
Magn Reson Med ; 90(3): 1166-1171, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37125620

RESUMO

PURPOSE: The purpose of this study was to identify and characterize newly discovered resonances appearing in the downfield proton MR spectrum (DF 1 H MRS) of the human calf muscle in vivo at 7T. METHODS: Downfield 1 H MRS was performed on the calf muscle of five healthy volunteers at 7T. A spectrally selective 90° E-BURP RF pulse with an excitation center frequency at 10.3 ppm and an excitation bandwidth of 2 ppm was used for DF 1 H MRS acquisition. RESULTS: In all participants, we observed new resonances at 9.7, 10.1, 10.3, and 10.9 ppm in the DF 1 H MRS. Phantom experiments at 37°C strongly suggest the new resonance at 9.7 ppm could be from H2-proton of the nicotinamide rings in nicotinamide riboside (NR) and nicotinamide mononucleotide (NMN) while the resonance at 10.1 ppm could be attributed to the indole -NH proton of L-tryptophan. We observed that the resonances at 10.1 and 10.9 ppm are significantly suppressed when the water resonance is saturated, indicating that these peaks have either 1 H chemical exchange or cross-relaxation with water. Conversely, the resonances at 9.7 and 10.3 ppm exhibit moderate signal reduction in the presence of water saturation. CONCLUSION: We have identified new proton resonances in vivo in human calf muscle occurring at chemical shifts of 9.7, 10.1, 10.3, and 10.9 ppm. These preliminary results are promising for investigating the role of NR/NMN and L-tryptophan metabolism in understanding the de novo and salvage pathways of NAD+ synthesis in skeletal muscle.


Assuntos
NAD , Prótons , Humanos , Triptofano , Músculo Esquelético/diagnóstico por imagem , Água
7.
Magn Reson Med ; 90(1): 259-269, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36971349

RESUMO

PURPOSE: To monitor the metabolic turnover of ß-hydroxybutyrate (BHB) oxidation using 2 H-MRS in conjunction with intravenous administration of 2 H labeled BHB. METHODS: Nine-month-old mice were infused with [3,4,4,4]-2 H4 -BHB (d4 -BHB; 3.11 g/kg) through the tail vein using a bolus variable infusion rate for a period of 90 min. The labeling of downstream cerebral metabolites from the oxidative metabolism of d4 -BHB was monitored using 2 H-MRS spectra acquired with a home-built 2 H surface coil on a 9.4T preclinical MR scanner with a temporal resolution of 6.25 min. An exponential model was fit to the BHB and glutamate/glutamine (Glx) turnover curves to determine rate constants of metabolite turnover and to aid in the visualization of metabolite time courses. RESULTS: Deuterium label was incorporated into Glx from BHB metabolism through the tricarboxylic acid (TCA) cycle, with an increase in the level of [4,4]-2 H2 -Glx (d2 -Glx) over time and reaching a quasi-steady state concentration of ∼0.6 ± 0.1 mM following 30 min of infusion. Complete oxidative metabolic breakdown of d4 -BHB also resulted in the formation of semi-heavy water (HDO), with a four-fold (10.1 to ∼42.1 ± 7.3 mM) linear (R2  = 0.998) increase in its concentration by the end of infusion. The rate constant of Glx turnover from d4 -BHB metabolism was determined to be 0.034 ± 0.004 min-1 . CONCLUSION: 2 H-MRS can be used to monitor the cerebral metabolism of BHB with its deuterated form by measuring the downstream labeling of Glx. The integration of 2 H-MRS with deuterated BHB substrate provides an alternative and clinically promising MRS tool to detect neurometabolic fluxes in healthy and disease conditions.


Assuntos
Encéfalo , Camundongos , Animais , Ácido 3-Hidroxibutírico , Deutério , Oxirredução , Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo
8.
Magn Reson Med ; 90(1): 11-20, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36807934

RESUMO

PURPOSE: The purpose of this study was to characterize the 1 H downfield MR spectrum from 8.0 to 10.0 ppm of human skeletal muscle at 7 T and determine the T1 and cross-relaxation rates of observed resonances. METHODS: We performed downfield MRS in the calf muscle of 7 healthy volunteers. Single-voxel downfield MRS was collected using alternately selective or broadband inversion-recovery sequences and spectrally selective 90° E-BURP RF pulse excitation centered at 9.0 ppm with bandwidth = 600 Hz (2.0 ppm). MRS was collected using TIs of 50-2500 ms. We modeled recovery of the longitudinal magnetization of three observable resonances using two models: (1) a three-parameter model accounting for the apparent T1 recovery and (2) a Solomon model explicitly including cross-relaxation effects. RESULTS: Three resonances were observed in human calf muscle at 7 T at 8.0, 8.2, and 8.5 ppm. We found broadband (broad) and selective (sel) inversion recovery T1 = mean ± SD (ms): T1-broad,8.0ppm = 2108.2 ± 664.5, T1-sel,8.0ppm = 753.6 ± 141.0 (p = 0.003); T1-broad,8.2ppm = 2033.5 ± 338.4, T1-sel,8.2ppm = 135.3 ± 35.3 (p < 0.0001); and T1-broad,8.5ppm = 1395.4 ± 75.4, T1-sel,8.5ppm = 107.1 ± 40.0 (p < 0.0001). Using the Solomon model, we found T1 = mean ± SD (ms): T1-8.0ppm = 1595.6 ± 491.1, T1-8.2ppm = 1737.2 ± 963.7, and T1-8.5ppm = 849.8 ± 282.0 (p = 0.04). Post hoc tests corrected for multiple comparisons showed no significant difference in T1 between peaks. The cross-relaxation rate σAB = mean ± SD (Hz) of each peak was σAB,8.0ppm = 0.76 ± 0.20, σAB,8.2ppm = 5.31 ± 2.27, and σAB,8.5ppm = 7.90 ± 2.74 (p < 0.0001); post hoc t-tests revealed the cross-relaxation rate of the 8.0 ppm peak was significantly slower than the peaks at 8.2 ppm (p = 0.0018) and 8.5 ppm (p = 0.0005). CONCLUSION: We found significant differences in effective T1 and cross-relaxation rates of 1 H resonances between 8.0 and 8.5 ppm in the healthy human calf muscle at 7 T.


Assuntos
Músculo Esquelético , Humanos , Espectroscopia de Ressonância Magnética , Músculo Esquelético/diagnóstico por imagem
9.
Magn Reson Med ; 90(4): 1537-1546, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37279010

RESUMO

PURPOSE: Nuclear Overhauser effect magnetization transfer ratio (NOEMTR ) is a technique used to investigate brain lipids and macromolecules in greater detail than other techniques and benefits from increased contrast at 7 T. However, this contrast can become degraded because of B 1 + $$ {\mathrm{B}}_1^{+} $$ inhomogeneities present at ultra-high field strengths. High-permittivity dielectric pads (DP) have been used to correct for these inhomogeneities via displacement currents generating secondary magnetic fields. The purpose of this work is to demonstrate that dielectric pads can be used to mitigate B 1 + $$ {\mathrm{B}}_1^{+} $$ inhomogeneities and improve NOEMTR contrast in the temporal lobes at 7 T. METHODS: Partial 3D NOEMTR contrast images and whole brain B 1 + $$ {\mathrm{B}}_1^{+} $$ field maps were acquired on a 7 T MRI across six healthy subjects. Calcium titanate DP, having a relative permittivity of 110, was placed next to the subject's head near the temporal lobes. Pad corrected NOEMTR images had a separate postprocessing linear correction applied. RESULTS: DP provided supplemental B 1 + $$ {\mathrm{B}}_1^{+} $$ to the temporal lobes while also reducing the B 1 + $$ {\mathrm{B}}_1^{+} $$ magnitude across the posterior and superior regions of the brain. This resulted in a statistically significant increase in NOEMTR contrast in substructures of the temporal lobes both with and without linear correction. The padding also produced a convergence in NOEMTR contrast toward approximately equal mean values. CONCLUSION: NOEMTR images showed significant improvement in temporal lobe contrast when DP were used, which resulted from an increase in B 1 + $$ {\mathrm{B}}_1^{+} $$ homogeneity across the entire brain slab. DP-derived improvements in NOEMTR are expected to increase the robustness of the brain substructural measures both in healthy and pathological conditions.


Assuntos
Encéfalo , Cabeça , Humanos , Encéfalo/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Mapeamento Encefálico , Campos Magnéticos , 5-Metiltetra-Hidrofolato-Homocisteína S-Metiltransferase
10.
NMR Biomed ; 36(6): e4780, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-35642353

RESUMO

Glutamate is the primary excitatory neurotransmitter in the mammalian central nervous system. As such, its proper regulation is essential to the healthy function of the human brain, and dysregulation of glutamate metabolism and compartmentalization underlies numerous neurological and neuropsychiatric pathologies. Glutamate-weighted chemical exchange saturation transfer (gluCEST) MRI is one of the only ways to non-invasively observe the relative concentration and spatial distribution of glutamate in the human brain. In the past 10 years, gluCEST has developed from a proof-of-concept experiment carried out in imaging phantoms and model systems to an increasingly sophisticated technique applied to reveal deviations from baseline neural metabolism in human beings, most notably in patients experiencing seizures of various origins or those on the psychosis spectrum. This article traces that progress, including in-depth discussion of the technical specifics of gluCEST and potential challenges to performing these experiments rigorously. We discuss the neurobiological context of glutamate, including the widely accepted hypotheses and models in the literature regarding its involvement in neurodegenerative diseases and other pathology. We then review the state of the art of in vivo glutamate detection by magnetic resonance imaging and the limitations on this front of in vivo MR spectroscopy. The gluCEST experiment is introduced and its advantages, challenges and limitations are thoroughly explored, beginning with the phantom experiment results demonstrated in the initial publication, through the latest approaches to correcting human brain images for B1 inhomogeneity. We then give a comprehensive overview of preclinical applications demonstrated to date, including Alzheimer's disease, Parkinson's disease, Huntington's disease, Traumatic brain injury and cancer, followed by a similar discussion of human studies. Finally, we highlight emerging applications, and discuss technical improvements on the horizon that hold promise for improving the robustness and versatility of gluCEST and its increasing presence in the arena of translational and precision medicine.


Assuntos
Lesões Encefálicas Traumáticas , Ácido Glutâmico , Animais , Humanos , Ácido Glutâmico/metabolismo , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética/métodos , Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo , Lesões Encefálicas Traumáticas/metabolismo , Mamíferos/metabolismo
11.
Neuroimage ; 251: 118977, 2022 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-35143973

RESUMO

In the technique presented here, dubbed 'qMRS', we quantify the change in 1H MRS signal following administration of 2H-labeled glucose. As in recent human DMRS studies, we administer [6,6'-2H2]-glucose orally to healthy subjects. Since 2H is not detectable by 1H MRS, the transfer of the 2H label from glucose to a downstream metabolite leads to a reduction in the corresponding 1H MRS resonance of the metabolite, even if the total concentration of both isoforms remains constant. Moreover, introduction of the deuterium label alters the splitting pattern of the proton resonances, making indirect detection of the deuterated forms- as well as the direct detection of the decrease in unlabeled form- possible even without a 2H coil. Because qMRS requires only standard 1H MRS acquisition methods, it can be performed using commonly implemented single voxel spectroscopy (SVS) and chemical shift imaging (CSI) sequences. In this work, we implement qMRS in semi-LASER based CSI, generating dynamic maps arising from the fitted spectra, and demonstrating the feasibility of using qMRS and qCSI to monitor dynamic metabolism in the human brain using a 7T scanner with no auxiliary hardware.


Assuntos
Glucose , Imageamento por Ressonância Magnética , Deutério , Glucose/metabolismo , Humanos , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética/métodos , Espectroscopia de Prótons por Ressonância Magnética
12.
Magn Reson Med ; 88(6): 2371-2377, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36005819

RESUMO

PURPOSE: To explore the presence of new resonances beyond 9.4 ppm from the human brain, down-field proton MRS was performed in vivo in the human brain on 6 healthy volunteers at 7 T. METHODS: To maximize the SNR, a large voxel was placed within the brain to cover the maximal area in such a way that sinus cavities were avoided. A spectrally selective 90° E-BURP pulse with an excitation bandwidth of 2 ppm was used to probe the spectral chemical shift range between 9.1 and 10.5 ppm. The E-BURP pulse was integrated with PRESS spatial localization to obtain non-water-suppressed proton MR spectra from the desired spectral region. RESULTS: In the down-field proton MRS obtained from all of the volunteers scanned, we identified a new peak consistently resonating at 10.1 ppm. Protons associated with this resonance are in cross-relaxation with the bulk water, as demonstrated by the water saturation and deuterium exchange experiments. CONCLUSION: Based on the chemical shift, this new peak was identified as the indole (-NH) proton of l-tryptophan (l-TRP) and was further confirmed from phantom experiments on l-TRP. These promising preliminary results potentially pave the way to investigate the role of cerebral metabolism of l-TRP in healthy and disease conditions.


Assuntos
Prótons , Triptofano , Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo , Deutério , Humanos , Espectroscopia de Ressonância Magnética/métodos , NAD/metabolismo , Serotonina/metabolismo , Triptofano/metabolismo
13.
Magn Reson Med ; 88(6): 2475-2484, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36178233

RESUMO

PURPOSE: Ultra-high field MR imaging lacks B1 + inhomogeneity due to shorter RF wavelengths used at higher field strengths compared to human anatomy. CEST techniques tend to be highly susceptible to B1 + inhomogeneities due to a high and uniform B1 + field being necessary to create the endogenous contrast. High-permittivity dielectric pads have seen increasing usage in MR imaging due to their ability to tailor the spatial distribution of the B1 + field produced. The purpose of this work is to demonstrate that dielectric materials can be used to improve glutamate weighted CEST (gluCEST) at 7T. THEORY AND METHODS: GluCEST images were acquired on a 7T system on six healthy volunteers. Aqueous calcium titanate pads, with a permittivity of approximately 110, were placed on either side in the subject's head near the temporal lobes. A post-processing correction algorithm was implemented in combination with dielectric padding to compare contrast improvement. Tissue segmentation was performed to assess the effect of dielectric pads on gray and white matter separately. RESULTS: GluCEST images demonstrated contrast enhancement in the lateral temporal lobe regions with dielectric pad placement. Tissue segmentation analysis showed an increase in correction effectiveness within the gray matter tissue compared to white matter tissue. Statistical testing suggested a significant difference in gluCEST contrast when pads were used and showed a difference in the gray matter tissue segment. CONCLUSION: The use of dielectric pads improved the B1 + field homogeneity and enhanced gluCEST contrast for all subjects when compared to data that did not incorporate padding.


Assuntos
Ácido Glutâmico , Substância Branca , Algoritmos , Substância Cinzenta , Humanos , Imageamento por Ressonância Magnética/métodos
14.
Mol Psychiatry ; 26(6): 2137-2147, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33479514

RESUMO

Low reward responsiveness (RR) is associated with poor psychological well-being, psychiatric disorder risk, and psychotropic treatment resistance. Functional MRI studies have reported decreased activity within the brain's reward network in individuals with RR deficits, however the neurochemistry underlying network hypofunction in those with low RR remains unclear. This study employed ultra-high field glutamate chemical exchange saturation transfer (GluCEST) imaging to investigate the hypothesis that glutamatergic deficits within the reward network contribute to low RR. GluCEST images were acquired at 7.0 T from 45 participants (ages 15-29, 30 females) including 15 healthy individuals, 11 with depression, and 19 with psychosis spectrum symptoms. The GluCEST contrast, a measure sensitive to local glutamate concentration, was quantified in a meta-analytically defined reward network comprised of cortical, subcortical, and brainstem regions. Associations between brain GluCEST contrast and Behavioral Activation System Scale RR scores were assessed using multiple linear regressions. Analyses revealed that reward network GluCEST contrast was positively and selectively associated with RR, but not other clinical features. Follow-up investigations identified that this association was driven by the subcortical reward network and network areas that encode the salience of valenced stimuli. We observed no association between RR and the GluCEST contrast within non-reward cortex. This study thus provides new evidence that reward network glutamate levels contribute to individual differences in RR. Decreased reward network excitatory neurotransmission or metabolism may be mechanisms driving reward network hypofunction and RR deficits. These findings provide a framework for understanding the efficacy of glutamate-modulating psychotropics such as ketamine for treating anhedonia.


Assuntos
Ácido Glutâmico , Transtornos Psicóticos , Adolescente , Adulto , Feminino , Humanos , Imageamento por Ressonância Magnética , Recompensa , Adulto Jovem
15.
Magn Reson Med ; 85(2): 802-817, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32820572

RESUMO

PURPOSE: Two-dimensional creatine CEST (2D-CrCEST), with a slice thickness of 10-20 mm and temporal resolution (τRes ) of about 30 seconds, has previously been shown to capture the creatine-recovery kinetics in healthy controls and in patients with abnormal creatine-kinase kinetics following the mild plantar flexion exercise. Since the distribution of disease burden may vary across the muscle length for many musculoskeletal disorders, there is a need to increase coverage in the slice-encoding direction. Here, we demonstrate the feasibility of 3D-CrCEST with τRes of about 30 seconds, and propose an improved voxel-wise B1+ -calibration approach for CrCEST. METHODS: The current 7T study with enrollment of 5 volunteers involved collecting the baseline CrCEST imaging for the first 2 minutes, followed by 2 minutes of plantar flexion exercise and then 8 minutes of postexercise CrCEST imaging, to detect the temporal evolution of creatine concentration following exercise. RESULTS: Very good repeatability of 3D-CrCEST findings for activated muscle groups on an intraday and interday basis was established, with coefficient of variance of creatine recovery constants (τCr ) being 7%-15.7%, 7.5%, and 5.8% for lateral gastrocnemius, medial gastrocnemius, and peroneus longus, respectively. We also established a good intraday and interday scan repeatability for 3D-CrCEST and also showed good correspondence between τCr measurements using 2D-CrCEST and 3D-CrCEST acquisitions. CONCLUSION: In this study, we demonstrated for the first time the feasibility and the repeatability of the 3D-CrCEST method in calf muscle with improved B1+ correction to measure creatine-recovery kinetics within a large 3D volume of calf muscle.


Assuntos
Creatina , Imageamento por Ressonância Magnética , Exercício Físico , Humanos , Cinética , Músculo Esquelético/diagnóstico por imagem
16.
Magn Reson Med ; 84(4): 1724-1733, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32301185

RESUMO

PURPOSE: Glutamate weighted Chemical Exchange Saturation Transfer (GluCEST) MRI is a noninvasive technique for mapping parenchymal glutamate in the brain. Because of the sensitivity to field (B0 ) inhomogeneity, the total acquisition time is prolonged due to the repeated image acquisitions at several saturation offset frequencies, which can cause practical issues such as increased sensitivity to patient motions. Because GluCEST signal is derived from the small z-spectrum difference, it often has a low signal-to-noise-ratio (SNR). We proposed a novel deep learning (DL)-based algorithm armed with wide activation neural network blocks to address both issues. METHODS: B0 correction based on reduced saturation offset acquisitions was performed for the positive and negative sides of the z-spectrum separately. For each side, a separate deep residual network was trained to learn the nonlinear mapping from few CEST-weighted images acquired at different ppm values to the one at 3 ppm (where GluCEST peaks) in the same side of the z-spectrum. RESULTS: All DL-based methods outperformed the "traditional" method visually and quantitatively. The wide activation blocks-based method showed the highest performance in terms of Structural Similarity Index (SSIM) and peak signal-to-noise ratio (PSNR), which were 0.84 and 25dB respectively. SNR increases in regions of interest were over 8dB. CONCLUSION: We demonstrated that the new DL-based method can reduce the entire GluCEST imaging time by ˜50% and yield higher SNR than current state-of-the-art.


Assuntos
Aprendizado Profundo , Ácido Glutâmico , Encéfalo/diagnóstico por imagem , Mapeamento Encefálico , Humanos , Imageamento por Ressonância Magnética
17.
Magn Reson Med ; 80(5): 2033-2039, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-29802635

RESUMO

PURPOSE: To investigate the reproducibility of gray and white matter glutamate contrast of a brain slice among a small group of healthy volunteers by using the 2D single-slice glutamate CEST (GluCEST) imaging technique. METHODS: Six healthy volunteers were scanned multiple times for within-day and between-day reproducibility. One more volunteer was scanned for within-day reproducibility at 7T MRI. Glutamate CEST contrast measurements were calculated for within subjects and among the subjects and the coefficient of variations are reported. RESULTS: The GluCEST measurements were highly reproducible in the gray and white matter area of the brain slice, whether it was within-day or between-day with a coefficient of variation of less than 5%. CONCLUSION: This preliminary study in a small group of healthy volunteers shows a high degree of reproducibility of GluCEST MRI in brain and holds promise for implementation in studying age-dependent changes in the brain.


Assuntos
Encéfalo/diagnóstico por imagem , Ácido Glutâmico/química , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/normas , Adulto , Idoso , Encéfalo/metabolismo , Feminino , Ácido Glutâmico/metabolismo , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
18.
Magn Reson Med ; 77(5): 1866-1873, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-27174078

RESUMO

PURPOSE: To develop a new faster and higher quality three-dimensional (3D) gagCEST MRI technique for reliable quantification of glycosaminoglycan (GAG) present in the human knee cartilages. METHODS: A new magnetization-prepared 3D gradient echo-based MRI pulse sequence has been designed to obtain the B0 inhomogeneity, B1 inhomogeneity, and CEST Z-spectra images. RESULTS: The gagCEST values of different compartments of knee cartilage are calculated using a newly developed technique for healthy subjects and a symptomatic knee cartilage degenerated subject. The effect of the acquired CEST saturation frequency offset step-size was investigated to establish the optimal step-size to obtain reproducible gagCEST maps. Our novel 3D gagCEST technique demonstrates markedly higher gagCEST contrast value than the previously reported 3D gagCEST studies. This study demonstrates the need for separate B0 and B1 inhomogeneity estimation and correction. CONCLUSION: The new technique provided high quality gagCEST maps with clearer visualization of different layers of knee cartilage with reproducible results. Magn Reson Med 77:1866-1873, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Assuntos
Cartilagem Articular/diagnóstico por imagem , Glicosaminoglicanos/química , Articulação do Joelho/diagnóstico por imagem , Joelho/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Adulto , Fatores Etários , Idoso , Animais , Humanos , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Articulação do Joelho/patologia , Magnetismo , Masculino , Movimento (Física) , Ratos , Reprodutibilidade dos Testes , Adulto Jovem
19.
Phys Chem Chem Phys ; 19(29): 19289-19299, 2017 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-28702543

RESUMO

Multidrug resistance against the existing antibiotics is one of the most challenging threats across the globe. Antimicrobial peptides (AMPs), in this regard, are considered to be one of the effective alternatives that can overcome bacterial resistance. MSI-594, a 24-residue linear alpha-helical cationic AMP, has been shown to function via the carpet mechanism to disrupt bacterial membrane systems. To better understand the role of lipid composition in the function of MSI-594, in the present study, eight different model membrane systems have been studied using accelerated molecular dynamics (aMD) simulations. The simulated results are helpful in discriminating the particular effects of cationic MSI-594 against zwitterionic POPC, anionic POPG and POPS, and neutral POPE lipid moieties. Additionally, the effects of various heterogeneous POPC/POPG (7 : 3), POPC/POPS (7 : 3), and POPG/POPE (1 : 3 and 3 : 1) bilayer systems on the dynamic interaction of MSI-594 have also been investigated. The effect on the lipid bilayer due to the interaction with the peptide is characterized by lipid acyl-chain order, membrane thickness, and acyl-chain dynamics. Our simulation results show that the lipid composition affects the membrane interaction of MSI-594, suggesting that membrane selectivity is crucial to its mechanism of action. The results reported in this study are helpful to obtain accurate atomistic-level information governing MSI-594 and its membrane disruptive antimicrobial mechanism of action, and to design next generation potent antimicrobial peptides.


Assuntos
Bicamadas Lipídicas/metabolismo , Simulação de Dinâmica Molecular , Peptídeos/metabolismo , Sequência de Aminoácidos , Peptídeos Catiônicos Antimicrobianos/química , Peptídeos Catiônicos Antimicrobianos/metabolismo , Interações Hidrofóbicas e Hidrofílicas , Bicamadas Lipídicas/química , Peptídeos/química , Fosfatidilcolinas/química , Fosfatidiletanolaminas/química , Fosfatidilgliceróis/química , Fosfatidilserinas/química , Estrutura Secundária de Proteína
20.
J Neurochem ; 139(3): 432-439, 2016 11.
Artigo em Inglês | MEDLINE | ID: mdl-27529288

RESUMO

Glutamate chemical exchange saturation transfer (GluCEST) MRI was used to measure metabolic changes in mice treated with 1-methyl-4-phenyl-1,2,3,6-tetrahydropyridine (MPTP) by mapping regional cerebral glutamate. The GluCEST contrast following MPTP treatment was correlated with 1 H-MR spectroscopy, motor function, and immunohistochemical measures. The GluCEST contrast was found to be significantly higher in the striatum and motor cortex of mice treated with MPTP than in controls (p < 0.001), which was confirmed by localized 1 H-MR spectroscopy. Elevated striatal GluCEST was positively associated with local astrogliosis measured by immunohistochemistry for glial fibrillary acidic protein. Additionally, a negative correlation was found between motor function, measured by the four-limb grip strength test, and GluCEST of the striatum (R = -0.705, p < 0.001) and the motor cortex (R = -0.617, p < 0.01), suggesting a role of elevated glutamate in the abnormal cerebral motor function regulation. The GluCEST contrast and glial fibrillary acidic protein immunostaining were unaltered in the thalamus indicating glutamate elevation was localized to the striatum and the motor cortex. These findings suggest that in addition to measuring spatial changes in glutamate, GluCEST may serve as an in vivo biomarker of metabolic and functional changes that may be applied to the assessment of a broad range of neuropathologies. Read the Editorial Highlight for this article on page 346.


Assuntos
Dopamina/deficiência , Ácido Glutâmico/metabolismo , Intoxicação por MPTP/metabolismo , Imageamento por Ressonância Magnética/métodos , 1-Metil-4-Fenil-1,2,3,6-Tetra-Hidropiridina , Animais , Astrócitos/efeitos dos fármacos , Química Encefálica/efeitos dos fármacos , Dopaminérgicos/toxicidade , Discinesia Induzida por Medicamentos/fisiopatologia , Proteína Glial Fibrilar Ácida/metabolismo , Gliose/patologia , Força da Mão , Intoxicação por MPTP/diagnóstico por imagem , Intoxicação por MPTP/fisiopatologia , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Neostriado/efeitos dos fármacos , Neostriado/metabolismo , Tirosina 3-Mono-Oxigenase/metabolismo , Proteína Vesicular 1 de Transporte de Glutamato/metabolismo