Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Eur J Anaesthesiol ; 32(11): 781-9, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25782662

RESUMO

BACKGROUND: Carotid endarterectomy is widely performed under regional anaesthesia. Ultrasound guidance is increasingly used in many regional anaesthetic procedures to improve safety and efficacy, and because it can reduce the amount of local anaesthetic required. Despite this, an ideal approach and dosing regimen for cervical plexus block remain elusive. OBJECTIVE: The aim of this study was to compare two different concentrations of ropivacaine in terms of analgesic adequacy, haemodynamic effects and plasma concentration using an ultrasound-guided triple approach for intermediate cervical plexus blockade. DESIGN: A randomised, placebo-controlled, blinded study. SETTING: University Clinic Salzburg, Department of Anaesthesiology, Perioperative Medicine and Intensive Care, Paracelsus Medical University, Salzburg, Austria, from 16 November 2012 to 17 September 2013. PATIENTS: Forty-six patients prospectively randomised to receive ultrasound-guided intermediate cervical block with either 20 ml ropivacaine 0.75% or 20 ml ropivacaine 0.375% each with 20 ml prilocaine 1%. INTERVENTION: After subcutaneous infiltration, blocks were performed using ultrasound-guided infiltration below the sternocleidomastoid muscle, and ultrasound-guided infiltration of the carotid sheath. Ropivacaine and prilocaine plasma concentrations were measured at intervals. MAIN OUTCOME: The primary study endpoint was the volume of supplementary lidocaine 1% required to achieve adequate surgical anaesthesia. Perioperative haemodynamic variables and pain scores were recorded. RESULTS: There was no statistical difference in the volume of supplementary lidocaine given: 5.0 (±3.63) ml in the ropivacaine 0.375% group and 5.17 (±2.76) ml in the ropivacaine 0.75% group (P = 0.846). Pain scores were similarly low across both groups. Measured concentrations of ropivacaine and prilocaine did not reach toxic levels in either group. Levels of ropivacaine were approximately two-fold higher in the 0.75% group [mean area under the curve (AUC) 10 531.11 (±2912.84) vs. 5264.34 ng (±1594.69), P < 0.0001]. Perioperative cardiovascular stability was excellent in both groups. There were no serious block-related complications. CONCLUSION: An ultrasound-guided intermediate block provides adequate anaesthesia for carotid thrombendarterectomy with a little need for supplementary local anaesthetic. Use of 0.375% ropivacaine provided similarly effective analgesia as 0.75%, but resulted in significantly lower plasma concentrations. TRIAL REGISTRATION: The study was registered at the European Clinical Trial Database (Eudra CT No.: 2012-002769) as well as at ClinicalTrials.gov (NCT01759940).


Assuntos
Amidas/administração & dosagem , Anestésicos Locais/administração & dosagem , Bloqueio do Plexo Cervical/métodos , Endarterectomia das Carótidas/métodos , Prilocaína/administração & dosagem , Idoso , Idoso de 80 Anos ou mais , Áustria , Relação Dose-Resposta a Droga , Quimioterapia Combinada , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Ropivacaina , Ultrassonografia de Intervenção
2.
Reg Anesth Pain Med ; 47(4): 205-211, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35012992

RESUMO

BACKGROUND AND OBJECTIVES: Cervical plexus blocks are commonly used to facilitate carotid endarterectomy (CEA) in the awake patient. These blocks can be divided into superficial, intermediate, and deep blocks by their relation to the fasciae of the neck. We hypothesized that the depth of block would have a significant impact on phrenic nerve blockade and consequently hemi-diaphragmatic motion. METHODS: We enrolled 45 patients in an observer blinded randomized controlled trial, scheduled for elective, awake CEA. Patients received either deep, intermediate, or superficial cervical plexus blocks, using 20 mL of 0.5% ropivacaine mixed with an MRI contrast agent. Before and after placement of the block, transabdominal ultrasound measurements of diaphragmatic movement were performed. Patients underwent MRI of the neck to evaluate spread of the injectate, as well as lung function measurements. The primary outcome was ipsilateral difference of hemi-diaphragmatic motion during forced inspiration between study groups. RESULTS: Postoperatively, forced inspiration movement of the ipsilateral diaphragm (4.34±1.06, 3.86±1.24, 2.04±1.20 (mean in cm±SD for superficial, intermediate and deep, respectively)) was statistically different between block groups (p<0.001). Differences were also seen during normal inspiration. Lung function, oxygen saturation, complication rates, and patient satisfaction did not differ. MRI studies indicated pronounced permeation across the superficial fascia, but nevertheless easily distinguishable spread of injectate within the targeted compartments. CONCLUSIONS: We studied the characteristics and side effects of cervical plexus blocks by depth of injection. Diaphragmatic dysfunction was most pronounced in the deep cervical plexus block group. TRIAL REGISTRATION NUMBER: EudraCT 2017-001300-30.


Assuntos
Anestesia por Condução , Bloqueio do Plexo Cervical , Anestésicos Locais , Bloqueio do Plexo Cervical/efeitos adversos , Humanos , Ropivacaina , Ultrassonografia de Intervenção
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA