Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Int J Cardiol ; 249: 479-485, 2017 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-28986062

RESUMO

BACKGROUND: The trial "Stress Echo (SE) 2020" evaluates novel applications of SE beyond coronary artery disease. The aim of the study was control quality and harmonize reading criteria. METHODS: One reader from 78 centers of the SE 2020 network asked for credentials to read a set of 20 SE video-clips selected by the core lab. All aspiring centers met the pre-requisite of high-volume and the years of experience in SE ranged from 5 to 31years (mean value 18years). The diagnostic gold standard was a reading by the core lab. The a priori determined pass threshold was 18/20 (≥90%). RESULTS: Of the initial 78 who started, 57 completed the first attempt: individual readers' score on first attempt ranged from 07/20 to 20/20 (accuracy from 35% to 100%, mean 78.7±13%) and 44 readers passed it. There was a very poor correlation between years of experience and the reader's score on first attempt (r=-0.161, p=0.231). Of the 13 readers who failed the first attempt, 12 took it again after the web-based session and their accuracy improved (74% vs. 96%, p<0.001). The kappa inter-observer agreement before and after web-based training was 0.59 on first attempt and rose to 0.91 on the last attempt. CONCLUSIONS: In SE reading, the volume of activity or years of experience is not synonymous with diagnostic quality. Qualitative analysis and operator-dependence can become a limiting weakness in clinical practice, in the absence of strict pathways of learning, credentialing and audit.


Assuntos
Cardiologistas/normas , Competência Clínica/normas , Doença das Coronárias/diagnóstico por imagem , Ecocardiografia sob Estresse/normas , Controle de Qualidade , Doença das Coronárias/epidemiologia , Ecocardiografia sob Estresse/métodos , Humanos , Internacionalidade , Reprodutibilidade dos Testes
2.
Circ Heart Fail ; 2(6): 523-31, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19919976

RESUMO

BACKGROUND: Blocking the tubuloglomerular feedback mechanism with adenosine A1 receptor antagonists seems to improve diuresis and sodium excretion without compromising the glomerular filtration rate in patients with heart failure. However, the direct cardiac effects of this compound class have not been investigated to date. METHODS AND RESULTS: In total, 111 patients (109 men and 2 women) received a 1-hour infusion of 5, 10, and 15 mg SLV320, an adenosine A1 receptor antagonist, placebo, or 40 mg furosemide. Mean age was 57.9 years, mean ejection fraction was 28.1%, 82 patients were of New York Heart Association class II, and 29 patients were of New York Heart Association class III. Hemodynamic parameters (heart rate, blood pressure, pulmonary capillary wedge pressure, mean pulmonary arterial pressure, systemic vascular resistance, right atrial pressure, and cardiac output) were determined. Kidney function was assessed by cystatin C measurements and by analysis of urine output and urine electrolytes. In addition, pharmacokinetics of SLV320 and ex vivo inhibition of adenosine A1 receptor activity were performed. SLV320 was well tolerated, and no serious adverse events were observed. Heart rate, blood pressure, pulmonary capillary wedge pressure, mean pulmonary arterial pressure, right atrial pressure, and cardiac output were not altered by any dose of SLV320. Pulmonary capillary wedge pressure was significantly (P=0.04) decreased by furosemide (-6.2+/-5.9 mm Hg). Systemic vascular resistance was significantly (P=0.04) increased in the furosemide group (+166.70+/-261.87 dynes . s(-1) . cm(-5)), whereas all SLV320 groups showed no significant alterations of systemic vascular resistance. Changes from baseline cystatin C plasma concentrations decreased after 10 mg SLV320 (-0.093+/-0.137 mg/L, P=0.046), whereas furosemide resulted in a significant (P=0.03) increase of cystatin C (+0.052+/-0.065 mg/L) versus baseline. All values represent mean changes+/-SD from baseline at 3 hours postdosing: SLV320 (10 and 15 mg) increased significantly sodium excretion and diuresis compared with placebo during the 0- to 6-hour collection period postdosing. CONCLUSIONS: SLV320 infusion shows no immediate effects on cardiac hemodynamics. SLV320 might improve glomerular filtration rate while simultaneously promoting natriuresis and diuresis. Clinical Trial Registration- clinicaltrials.gov Indentifier: NCT00160134.


Assuntos
Antagonistas do Receptor A1 de Adenosina , Fármacos Cardiovasculares/uso terapêutico , Cicloexanos/uso terapêutico , Insuficiência Cardíaca/tratamento farmacológico , Hemodinâmica/efeitos dos fármacos , Compostos Heterocíclicos com 2 Anéis/uso terapêutico , Nefropatias/tratamento farmacológico , Rim/efeitos dos fármacos , Miocárdio/metabolismo , Função Ventricular Esquerda/efeitos dos fármacos , Fármacos Cardiovasculares/administração & dosagem , Fármacos Cardiovasculares/efeitos adversos , Fármacos Cardiovasculares/farmacocinética , Cicloexanos/administração & dosagem , Cicloexanos/efeitos adversos , Cicloexanos/farmacocinética , Diurese/efeitos dos fármacos , Diuréticos/uso terapêutico , Relação Dose-Resposta a Droga , Método Duplo-Cego , Europa (Continente) , Feminino , Furosemida/uso terapêutico , Taxa de Filtração Glomerular/efeitos dos fármacos , Insuficiência Cardíaca/metabolismo , Insuficiência Cardíaca/fisiopatologia , Compostos Heterocíclicos com 2 Anéis/administração & dosagem , Compostos Heterocíclicos com 2 Anéis/efeitos adversos , Compostos Heterocíclicos com 2 Anéis/farmacocinética , Humanos , Infusões Intravenosas , Rim/metabolismo , Rim/fisiopatologia , Nefropatias/metabolismo , Nefropatias/fisiopatologia , Testes de Função Renal , Masculino , Pessoa de Meia-Idade , Natriurese/efeitos dos fármacos , Receptor A1 de Adenosina/metabolismo , Volume Sistólico/efeitos dos fármacos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA