Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 66
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Small ; 20(12): e2307565, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37946670

RESUMO

Liquid crystal elastomers (LCEs) with promising applications in the field of actuators and soft robotics are reported. However, most of them are activated by external heating or light illumination. The examples of electroactive LCEs are still limited; moreover, they are monofunctional with one type of deformation (bending or contraction). Here, the study reports on trilayer electroactive LCE (eLCE) by intimate combination of LCE and ionic electroactive polymer device (i-EAD). This eLCE is bi-functional and can perform either bending or contractile deformations by the control of the low-voltage stimulation. By applying a voltage of ±2 V at 0.1 Hz, the redox behavior and associated ionic motion provide a bending strain difference of 0.80%. Besides, by applying a voltage of ±6 V at 10 Hz, the ionic current-induced Joule heating triggers the muscle-like linear contraction with 20% strain for eLCE without load. With load, eLCE can lift a weight of 270 times of eLCE-actuator weight, while keeping 20% strain and affording 5.38 kJ·m-3 work capacity. This approach of combining two smart polymer technologies (LCE and i-EAD) in a single device is promising for the development of smart materials with multiple degrees of freedom in soft robotics, electronic devices, and sensors.

2.
Soft Matter ; 17(48): 10786-10805, 2021 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-34859250

RESUMO

Electroactive polymers based on dielectric elastomers are stretchable and compressible capacitors that can act as transducers between electrical and mechanical energies. Depending on the targeted application, soft actuators, sensors or mechanical-energy harvesters can be developed. Compared with conventional technologies, they present a promising combination of properties such as being soft, silent, light and miniaturizable. Most of the research on dielectric elastomer actuators has focused on obtaining the highest strain, either from technological solutions using commercially available materials or through the development of new materials. It is commonly accepted that a high electrical breakdown field, a low Young's modulus and a high dielectric constant are targets. However, the interdependency of these properties makes the evaluation and comparison of these materials complex. In addition, dielectric elastomers can suffer from electromechanical instability, which amplifies their complexity. The scope of this review is to tackle these difficulties. Thus, first, two physical parameters are introduced, one related to the energy converted by the dielectric elastomer and another to its electromechanical stability. These numbers are then used to compare dielectric elastomers according to a general and rational methodology considering their physicochemical and electromechanical properties. Based on this methodology, different families of commercially available dielectric elastomers are first analyzed. Then, different polymer modification methods are presented, and the resulting modified elastomers are screened. Finally, we conclude on the trends enabling the choice of the most suitable modification procedure to obtain the desired elastomer. From this review work, we would like to contribute to affording a quick identification method, including a graphic representation, to evaluate and develop the dielectric materials that are suitable for a desired actuator.

3.
Catheter Cardiovasc Interv ; 89(5): 888-897, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27315598

RESUMO

OBJECTIVES: To quantify the impact of image optimization on absorbed radiation dose and associated risk in children undergoing cardiac catheterization. BACKGROUND: Various imaging and fluoroscopy system technical parameters including camera magnification, source-to-image distance, collimation, antiscatter grids, beam quality, and pulse rates, all affect radiation dose but have not been well studied in younger children. METHODS: We used anthropomorphic phantoms (ages: newborn and 5 years old) to measure surface radiation exposure from various imaging approaches and estimated absorbed organ doses and effective doses (ED) using Monte Carlo simulations. Models developed in the National Academies' Biological Effects of Ionizing Radiation VII report were used to compare an imaging protocol optimized for dose reduction versus suboptimal imaging (+20 cm source-to-image-distance, +1 magnification setting, no collimation) on lifetime attributable risk (LAR) of cancer. RESULTS: For the newborn and 5-year-old phantoms, respectively ED changes were as follows: +157% and +232% for an increase from 6-inch to 10-inch camera magnification; +61% and +59% for a 20 cm increase in source-to-image-distance; -42% and -48% with addition of 1-inch periphery collimation; -31% and -46% with removal of the antiscatter grid. Compared with an optimized protocol, suboptimal imaging increased ED by 2.75-fold (newborn) and fourfold (5 years old). Estimated cancer LAR from 30-min of posteroanterior fluoroscopy using optimized versus suboptimal imaging, respectively was 0.42% versus 1.23% (newborn female), 0.20% versus 0.53% (newborn male), 0.47% versus 1.70% (5-year-old female) and 0.16% versus 0.69% (5-year-old male). CONCLUSIONS: Radiation-related risks to children undergoing cardiac catheterization can be substantial but are markedly reduced with an optimized imaging approach. © 2016 Wiley Periodicals, Inc.


Assuntos
Cateterismo Cardíaco/métodos , Fluoroscopia/efeitos adversos , Neoplasias Induzidas por Radiação/etiologia , Imagens de Fantasmas , Medição de Risco/métodos , Cateterismo Cardíaco/efeitos adversos , Pré-Escolar , Feminino , Humanos , Incidência , Recém-Nascido , Masculino , Neoplasias Induzidas por Radiação/epidemiologia , Doses de Radiação , Estados Unidos/epidemiologia
4.
AJR Am J Roentgenol ; 204(5): W579-85, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25905965

RESUMO

OBJECTIVE: The purpose of this study is to measure the organ doses and effective dose (ED) for parathyroid 4D CT and scintigraphy and to estimate the lifetime attributable risk of cancer incidence associated with imaging. MATERIALS AND METHODS: Organ radiation doses for 4D CT and scintigraphy were measured on the basis of imaging with our institution's protocols. An anthropomorphic phantom with metal oxide semiconductor field effect transistor detectors was scanned to measure CT organ dose. Organ doses from the radionuclide were based on International Commission for Radiological Protection report 80. ED was calculated for 4D CT and scintigraphy and was used to estimate the lifetime attributable risk of cancer incidence for patients differing in age and sex with the approach established by the Biologic Effects of Ionizing Radiation VII report. A 55-year-old woman was selected as the standard patient according to the demographics of patients with primary hyperparathyroidism. RESULTS: Organs receiving the highest radiation dose from 4D CT were the thyroid (150.6 mGy) and salivary glands (137.8 mGy). For scintigraphy, the highest organ doses were to the colon (41.5 mGy), gallbladder (39.8 mGy), and kidneys (32.3 mGy). The ED was 28 mSv for 4D CT, compared with 12 mSv for scintigraphy. In the exposed standard patient, the lifetime attributable risk for cancer incidence was 193 cancers/100,000 patients for 4D CT and 68 cancers/100,000 patients for scintigraphy. Given a baseline lifetime incidence of cancer of 46,300 cancers/100,000 patients, imaging results in an increase in lifetime incidence of cancer over baseline of 0.52% for 4D CT and 0.19% for scintigraphy. CONCLUSION: The ED of 4D CT is more than double that of scintigraphy, but both studies cause negligible increases in lifetime risk of cancer. Clinicians should not allow concern for radiation-induced cancer to influence decisions regarding workup in older patients.


Assuntos
Tomografia Computadorizada Quadridimensional , Neoplasias Induzidas por Radiação/etiologia , Doenças das Paratireoides/diagnóstico por imagem , Doses de Radiação , Feminino , Humanos , Incidência , Masculino , Neoplasias Induzidas por Radiação/epidemiologia , Imagens de Fantasmas , Cintilografia , Medição de Risco , Fatores de Risco
5.
AJR Am J Roentgenol ; 202(5): 1072-7, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24758663

RESUMO

OBJECTIVE: The purpose of this study was threefold: to estimate the organ doses and effective doses (EDs) for seven neurovascular imaging protocols, to study the effect of beam collimation on ED, and to derive protocol-specific dose-area product (DAP)-to-ED conversion factors. MATERIALS AND METHODS: A cone-beam CT system was used to measure the organ doses for seven neurovascular imaging protocols. Two datasets were obtained: seven protocols without beam collimation (FOV, entire head) and four with beam collimation (FOV, from the base to the top of the skull). Measurements were performed on an adult male anthropomorphic phantom with 20 metal oxide semiconductor field-effect transistor (MOSFET) detectors placed in selected organs. The DAP values were recorded from the console. The EDs of five protocols were also estimated using Monte Carlo simulations software. The ED values were computed by multiplying measured organ doses to corresponding International Commission on Radiological Protection tissue-weighting factors. RESULTS: Without collimation, the EDs ranged from 0.16 to 1.6 mSv, and the DAP-to-ED conversion factors ranged from 0.035 to 0.076 mSv/Gy·cm(2). For the four protocols investigated with beam collimation, the ED was reduced by a factor of approximately 2, and the DAP-to-ED conversion factors were reduced by approximately 30%. For the five protocols also estimated with the Monte Carlo method, the estimated EDs were in agreement (< 20% deviation) with those determined by the MOSFET method. CONCLUSION: We have estimated ED for standard adult neuroimaging protocols in a 3D rotational angiography system. Our results provide a simple means of ED estimation using DAP console readings.


Assuntos
Angiografia/métodos , Protocolos Clínicos , Tomografia Computadorizada de Feixe Cônico/normas , Neuroimagem/métodos , Imagens de Fantasmas , Doses de Radiação , Adulto , Humanos , Masculino , Método de Monte Carlo
6.
ACS Appl Mater Interfaces ; 16(11): 13869-13881, 2024 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-38466181

RESUMO

Poly(ethylene glycol) methyl ether methacrylate polymer networks (PEO-based networks), with or without anionic bis(trifluoromethanesulfonyl)imide (TFSI)-grafted groups, are promising electrolytes for Li-metal all solid-state batteries. Nevertheless, there is a need to enhance our current understanding of the physicochemical characteristics of these polymer networks to meet the mechanical and ionic conductivity property requirements for Li battery electrolyte materials. To address this challenge, our goal is to investigate the impact of the cross-linking density of the PEO-based network and the ethylene oxide/lithium ratio on mechanical properties (such as glass transition temperature and storage modulus) and ionic conductivity. We have synthesized a series of cross-linked PEO-based polymers (si-SPE for single ion solid polymer electrolyte) via solvent-free radical copolymerization. These polymers are synthesized by using commercially available lithium 3-[(trifluoromethane)sulfonamidosulfonyl]propyl methacrylate (LiMTFSI), poly(ethylene glycol)methyl ether methacrylate (PEGM), and [poly(ethylene glycol) dimethacrylate] (PEGDM). In addition, we have synthesized a series of cross-linked PEO-based polymers (SPE for solid polymer electrolyte) using LiTFSI as the ionic species. Most of the resulting polymer films are amorphous, self-standing, flexible, homogeneous, and thermally stable. Interestingly, our research has revealed a correlation between ionic conductivity and mechanical properties in both the SPE and si-SPE series. Ionic conductivity increases as glass transition temperature, α relaxation temperature, and storage modulus decrease, suggesting that Li+ transport is influenced by polymer chain flexibility and Li+/EO interaction.

7.
J Urol ; 189(6): 2142-6, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23261481

RESUMO

PURPOSE: Patients with recurrent nephrolithiasis are often evaluated and followed with computerized tomography. Obesity is a risk factor for nephrolithiasis. We evaluated the radiation dose of computerized tomography in obese and nonobese adults. MATERIALS AND METHODS: We scanned a validated, anthropomorphic male phantom according to our institutional renal stone evaluation protocol. The obese model consisted of the phantom wrapped in 2 Custom Fat Layers (CIRS, Norfolk, Virginia), which have been verified to have the same radiographic tissue density as fat. High sensitivity metal oxide semiconductor field effect transistor dosimeters were placed at 20 organ locations in the phantoms to measure organ specific radiation doses. The nonobese and obese models have an approximate body mass index of 24 and 30 kg/m(2), respectively. Three runs of renal stone protocol computerized tomography were performed on each phantom under automatic tube current modulation. Organ specific absorbed doses were measured and effective doses were calculated. RESULTS: The bone marrow of each model received the highest dose and the skin received the second highest dose. The mean ± SD effective dose for the nonobese and obese models was 3.04 ± 0.34 and 10.22 ± 0.50 mSv, respectively (p <0.0001). CONCLUSIONS: The effective dose of stone protocol computerized tomography in obese patients is more than threefold higher than the dose in nonobese patients using automatic tube current modulation. The implication of this finding extends beyond the urological stone population and adds to our understanding of radiation exposure from medical imaging.


Assuntos
Obesidade/complicações , Imagens de Fantasmas , Doses de Radiação , Tomografia Computadorizada por Raios X/efeitos adversos , Carga Corporal (Radioterapia) , Índice de Massa Corporal , Humanos , Masculino , Modelos Teóricos , Nefrolitíase/diagnóstico por imagem , Monitoramento de Radiação/métodos , Recidiva , Valores de Referência , Tomografia Computadorizada por Raios X/métodos
8.
J Urol ; 190(6): 2117-23, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23764073

RESUMO

PURPOSE: Computerized tomography use increased exponentially in the last 3 decades, and it is commonly used to evaluate many urological conditions. Ionizing radiation exposure from medical imaging is linked to the risk of malignancy. We measured the organ and calculated effective doses of different studies to determine whether the dose-length product method is an accurate estimation of radiation exposure. MATERIALS AND METHODS: An anthropomorphic male phantom validated for human organ dosimetry measurements was used to determine radiation doses. High sensitivity metal oxide semiconductor field effect transistor dosimeters were placed at 20 organ locations to measure specific organ doses. For each study the phantom was scanned 3 times using our institutional protocols. Organ doses were measured and effective doses were calculated on dosimetry. Effective doses measured by a metal oxide semiconductor field effect transistor dosimeter were compared to calculated effective doses derived from the dose-length product. RESULTS: The mean±SD effective dose on dosimetry for stone protocol, chest and abdominopelvic computerized tomography, computerized tomography urogram and renal cell carcinoma protocol computerized tomography was 3.04±0.34, 4.34±0.27, 5.19±0.64, 9.73±0.71 and 11.42±0.24 mSv, respectively. The calculated effective dose for these studies Was 3.33, 2.92, 5.84, 9.64 and 10.06 mSv, respectively (p=0.8478). CONCLUSIONS: The effective dose varies considerable for different urological computerized tomography studies. Renal stone protocol computerized tomography shows the lowest dose, and computerized tomography urogram and the renal cell carcinoma protocol accumulate the highest effective doses. The calculated effective dose derived from the dose-length product is a reasonable estimate of patient radiation exposure.


Assuntos
Técnicas de Diagnóstico Urológico/normas , Imagens de Fantasmas , Doses de Radiação , Tomografia Computadorizada por Raios X/normas , Humanos , Masculino
9.
Pediatr Radiol ; 43(9): 1117-27, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23636537

RESUMO

BACKGROUND: Advanced multidetector CT systems facilitate volumetric image acquisition, which offers theoretic dose savings over helical acquisition with shorter scan times. OBJECTIVE: Compare effective dose (ED), scan duration and image noise using 320- and 64-detector CT scanners in various acquisition modes for clinical chest, abdomen and pelvis protocols. MATERIALS AND METHODS: ED and scan durations were determined for 64-detector helical, 160-detector helical and volume modes under chest, abdomen and pelvis protocols on 320-detector CT with adaptive collimation and 64-detector helical mode on 64-detector CT without adaptive collimation in a phantom representing a 5-year-old child. Noise was measured as standard deviation of Hounsfield units. RESULTS: Compared to 64-detector helical CT, all acquisition modes on 320-detector CT resulted in lower ED and scan durations. Dose savings were greater for chest (27-46%) than abdomen/pelvis (18-28%) and chest/abdomen/pelvis imaging (8-14%). Noise was similar across scanning modes, although some protocols on 320-detector CT produced slightly higher noise. CONCLUSION: Dose savings can be achieved for chest, abdomen/pelvis and chest/abdomen/pelvis examinations on 320-detector CT compared to helical acquisition on 64-detector CT, with shorter scan durations. Although noise differences between some modes reached statistical significance, this is of doubtful diagnostic significance and will be studied further in a clinical setting.


Assuntos
Artefatos , Imageamento Tridimensional/instrumentação , Imagens de Fantasmas , Doses de Radiação , Radiometria , Tomografia Computadorizada Espiral/instrumentação , Imagem Corporal Total/instrumentação , Criança , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Fatores de Tempo
10.
RSC Adv ; 13(10): 6656-6667, 2023 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-36860526

RESUMO

The growing demand for flexible, stretchable, and wearable devices has boosted the development of ionogels used as polymer electrolytes. Developing healable ionogels based on vitrimer chemistry is a promising approach to improve their lifetimes as these materials are usually subjected to repeated deformation during functioning and are susceptible to damage. In this work, we reported in the first place the preparation of polythioether vitrimer networks based on the not extensively studied associative S-transalkylation exchange reaction using thiol-ene Michael addition. Thanks to the exchange reaction of sulfonium salts with thioether nucleophiles, these materials demonstrated vitrimer properties such as healing and stress relaxation. The fabrication of dynamic polythioether ionogels was then demonstrated by loading 1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide or 1-ethyl-3-methylimidazolium trifluoromethanesulfonate (EMIM triflate) within the polymer network. The resulting ionogels exhibited Young's modulus of 0.9 MPa and ionic conductivities in the order of 10-4 S cm-1 at room temperature. It has been found that adding ionic liquids (ILs) changes the dynamic properties of the systems, most likely due to a dilution effect of the dynamic functions by the IL but also due to a screening effect of the alkyl sulfonium OBrs-couple by the ions of the IL itself. To the best of our knowledge, these are the first vitrimer ionogels based on an S-transalkylation exchange reaction. While the addition of ILs resulted in less efficient dynamic healing at a given temperature, these ionogels can provide materials with more dimensional stability at application temperatures and can potentially pave the way for the development of tunable dynamic ionogels for flexible electronics with a longer lifespan.

11.
ACS Appl Polym Mater ; 5(1): 529-541, 2023 Jan 13.
Artigo em Inglês | MEDLINE | ID: mdl-36686061

RESUMO

The growing demand for all-solid flexible, stretchable, and wearable devices has boosted the need for liquid-free and stretchable ionoelastomers. These ionic conducting materials are subjected to repeated deformations during functioning, making them susceptible to damage. Thus, imparting cross-linked materials with healing ability seems particularly promising to improve their durability. Here, a polymeric ionic liquid (PIL) bearing allyl functional groups was synthesized based on the quaternization of N-allylimidazole with a copolymer rubber of poly(epichlorohydrin) and poly(ethylene oxide) (PEO). The resulting PIL was then cross-linked with dynamic boronic ester cross-linkers 2,2'-(1,4-Phenylene)-bis[4-mercaptan-1,3,2-dioxaborolane] (BDB) through thiol-ene "click" photoaddition. PEO dangling chains were additionally introduced for acting as free volume enhancers. The properties of the resulting all-solid PIL networks were investigated by tuning dynamic cross-linkers and dangling chain contents. Adjusting the cross-linker and dangling chain quantities yielded soft (0.2 MPa), stretchable (300%), and highly conducting ionoelastomers (1.6 × 10-5 S·cm-1 at 30 °C). The associative exchange reaction between BDB endowed these materials with vitrimer properties such as healing and recyclability. The recycled materials were able to retain their original mechanical properties and ionic conductivity. These healable PIL networks display a great potential for applications requiring solid electrolytes with high ionic conductivity, healing ability, and reprocessability.

12.
Environ Sci Pollut Res Int ; 30(38): 89293-89310, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37452243

RESUMO

The dyke system plays a vital role in cultivating rice intensively in the Vietnamese Mekong Delta, which protects rice paddy fields from annual floods. This study aimed to examine whether the full-dyke system (FD, which restricts water exchange for a long time) can cause degradation of surface water quality and reduction in benthic invertebrate biodiversity. The surface water quality and benthic invertebrate community were compared between the FD and semi-dyke systems (SD, which permits water exchange during flooding season) using a large number of samples collected seasonally in 2019. The results showed that the surface water quality within the FD system had significantly higher concentrations of TSS, COD, BOD5, N-NO3-, N-TKN, P-PO43-, and TP than compared to the SD system (p < 0.05), indicating greater pollution levels. The benthic invertebrate community was less diverse in the FD system than in the SD system. Only 17 species (belonging to 4 families) were detected in the FD system, and 30 species (belonging to 5 families) were detected in the SD system. The benthic invertebrate community structure changes and biodiversity loss were associated with degraded water quality. The P-PO43- and TP parameters were negatively correlated with the number of species, density, and biomass in the FD system and with the Shannon-Wiener (H') index in the SD system. In conclusion, the FD system has been degrading water quality and causing biodiversity loss.


Assuntos
Invertebrados , Rios , Humanos , Animais , Vietnã , Rios/química , Invertebrados/química , Qualidade da Água , Biodiversidade
13.
AJR Am J Roentgenol ; 198(3): 621-7, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22358002

RESUMO

OBJECTIVE: The purpose of this study was to assess the effect of peak kilovoltage on radiation dose and image quality in adult neck MDCT. MATERIALS AND METHODS: An anthropomorphic phantom with metal oxide semiconductor field effect transistor detectors was imaged with a 64-MDCT scanner. The reference CT protocol called for 120 kVp, and images obtained with that protocol were compared with CT images obtained with protocols entailing 80, 100, and 140 kVp. All imaging was performed with automatic tube current modulation. Organ dose and effective dose were determined for each protocol and compared with those obtained with the 120-kVp protocol. Image noise was evaluated objectively and subjectively for each protocol. RESULTS: The highest organ doses for all protocols were to the thyroid, ocular lens, skin, and mandible. The greatest reductions in organ dose were for the bone marrow of the cervical spine and mandible: 43% and 35% with the 100-kVp protocol and 63% and 53% with the 80-kVp protocol. Effective dose decreased as much as 9% with the 100-kVp protocol and 12% with the 80-kVp protocol. Use of the 140-kVp protocol was associated with an increase in organ dose as high as 64% for bone marrow in the cervical spine and a 19% increase in effective dose. Image noise increased with lower peak kilovoltage. The measured noise difference was greatest at 80 kVp, absolute increases were less than 2.5 HU. There was no difference in subjective image quality among protocols. CONCLUSION: Reducing the voltage from 120 to 80 kVp for neck CT can result in greater than 50% reduction in the absorbed organ dose to the bone marrow of the cervical spine and mandible without impairment in subjective image quality.


Assuntos
Pescoço/diagnóstico por imagem , Tomografia Computadorizada Espiral/métodos , Adulto , Humanos , Imagens de Fantasmas , Doses de Radiação , Proteção Radiológica , Interpretação de Imagem Radiográfica Assistida por Computador , Valores de Referência
14.
AJR Am J Roentgenol ; 199(5): 1129-35, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23096189

RESUMO

OBJECTIVE: The purpose of this study is to determine patient dose estimates for clinical pediatric cardiac-gated CT angiography (CTA) protocols on a 320-MDCT volume scanner. MATERIALS AND METHODS: Organ doses were measured using 20 metal oxide semiconductor field effect transistor (MOSFET) dosimeters. Radiation dose was estimated for volumetrically acquired clinical pediatric prospectively and retrospectively ECG-gated cardiac CTA protocols in 5-year-old and 1-year-old anthropomorphic phantoms on a 320-MDCT scanner. Simulated heart rates of 60 beats/min (5-year-old phantom) and 120 beats/min (1- and 5-year-old phantoms) were used. Effective doses (EDs) were calculated using average measured organ doses and International Commission on Radiological Protection 103 tissue-weighting factors. Dose-length product (DLP) was recorded for each examination and was used to develop dose conversion factors for pediatric cardiac examinations acquired with volume scan mode. DLP was also used to estimate ED according to recently published dose conversion factors for pediatric helical chest examinations. Repeated measures and paired Student t test analyses were performed. RESULTS: For the 5-year-old phantom, at 60 beats/min, EDs ranged from 1.2 mSv for a prospectively gated examination to 4.5 mSv for a retrospectively gated examination. For the 5-year-old phantom, at 120 beats/min, EDs ranged from 3.0 mSv for a prospectively gated examination to 4.9 mSv for a retrospectively gated examination. For the 1-year-old phantom, at 120 beats/min, EDs ranged from 2.7 mSv for a prospectively gated examination to 4.5 mSv for a retrospectively gated examination. CONCLUSION: EDs for 320-MDCT volumetrically acquired ECG-gated pediatric cardiac CTA are lower than those published for conventional 16- and 64-MDCT scanners.


Assuntos
Técnicas de Imagem de Sincronização Cardíaca , Angiografia Coronária/métodos , Imagens de Fantasmas , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Carga Corporal (Radioterapia) , Calibragem , Pré-Escolar , Humanos , Lactente , Estudos Prospectivos , Estudos Retrospectivos
15.
AJR Am J Roentgenol ; 198(5): 1132-8, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22528904

RESUMO

OBJECTIVE: The purpose of this study was to assess the difference in absorbed organ dose and image quality for MDCT neck protocols using automatic tube current modulation alone compared with organ-based dose modulation and in-plane thyroid bismuth shielding. MATERIALS AND METHODS: An anthropomorphic female phantom with metal oxide semiconductor field effect transistor (MOSFET) detectors was scanned on a 64-MDCT scanner. The protocols included a reference neck CT protocol using automatic tube current modulation and three modified protocols: organ-based dose modulation, automatic tube current modulation with thyroid shield, and organ-based dose modulation with thyroid shield. Image noise was evaluated quantitatively with the SD of the attenuation value, and subjectively by two neuroradiologists. RESULTS: Organ-based dose modulation, automatic tube current modulation with thyroid shield, and organ-based dose modulation with thyroid shield protocols reduced the thyroid dose by 28%, 33%, and 45%, respectively, compared with the use of automatic tube current modulation alone (p ≤ 0.005). Organ-based dose modulation also reduced the radiation dose to the ocular lens (33-47%) compared with the use of automatic tube current modulation (p ≤ 0.04). There was no significant difference in measured noise and subjective image quality between the protocols. CONCLUSION: Both organ-based dose modulation and thyroid shields significantly reduce the thyroid organ dose without degradation of subjective image quality compared with automatic tube current modulation. Organ-based dose modulation has the additional benefit of dose reduction to the ocular lens.


Assuntos
Doses de Radiação , Proteção Radiológica/instrumentação , Glândula Tireoide/efeitos da radiação , Tomografia Computadorizada por Raios X , Carga Corporal (Radioterapia) , Feminino , Humanos , Pescoço , Imagens de Fantasmas , Radiometria , Software
16.
Plants (Basel) ; 11(20)2022 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-36297818

RESUMO

Capsicum (Capsicum annuum L.) belongs to the Solanaceae family and is an economically important vegetable crop. However, the crop is very sensitive to adverse weather conditions such as high temperatures and excessive sunlight, which cause flower and young fruit to drop and sunscald to mature fruits. Using protected cultivation such as shade covers or net houses is a feasible agronomic approach to protect the crop from high light intensity, which increases plant growth, reduces fruit damage, and increases marketable fruit yield and quality. Low-cost protected cropping options such as fixed-roof net houses have proved cost-effective and suitable for fruiting vegetable production in semi-arid climatic regions. However, this structure type is unable to protect the crops from rainfall, is prone to cyclone damage and is inflexible to accommodate various vegetable crops which have different requirements for healthy and productive growth. This study was conducted in Carnarvon, which has semi-arid climatic conditions and is a key horticultural district of Western Australia, to compare the Retractable Roof Production System (RRPS) and open field (OF) conditions in the production of capsicum. The data showed that the RRPS modified the internal light, temperature and humidity in favour of the capsicum crop. The RRPS-grown capsicum had higher plant height and lower canopy temperature on hot days than those in the OF. The mean marketable fruit yield of capsicum varieties grown in the RRPS was significantly higher than those in the OF with fruit yields of 97 t ha-1 and 39.1 t ha-1, respectively, but the fruit quality remained unchanged. Overall, the data suggest that the RRPS altered the internal microenvironment and enhanced capsicum crop growth, physiology and fruit yield by setting climatic parameters to automatically control the opening and closing of the roof, the insect net and side curtains, and activation of the fogging system. The future perspective of the deployment of RRPS for capsicum production under climatic conditions in Carnarvon was also discussed.

17.
Australas J Ageing ; 41(2): e122-e130, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34792256

RESUMO

OBJECTIVE: To investigate the prevalence and factors associated with frailty in rural and urban older outpatients in Vietnam. METHODS: This cross-sectional study included 1084 outpatients (aged ≥60 years; mean age 71.7 ± 7.4 years; female 65%) from rural (n = 600) and urban (n = 484) geriatric clinics from December 2019 to July 2020. Frailty was assessed using Fried frailty phenotype. Factors associated with frailty were assessed using logistic regression. RESULTS: Overall, frailty prevalence was 28% (rural, 26%; urban, 30%; p = 0.220). Factors associated with frailty were older age (odds ratio [OR] 1.16, 95% confidence interval [CI] 1.13-1.20, p < 0.001), being underweight (OR 1.88, 95% CI 1.10-3.27, p = 0.025) and limitations in activities of daily living (ADLs) (OR 6.04, 95% CI 1.63-22.41, p = 0.007) and instrumental ADLs (OR 5.83, 95% CI 3.74-9.08, p < 0.001). Higher education (OR 0.47, 95% CI 0.29-0.76, p = 0.002) and productive work (OR 0.39, 95% CI 0.21-0.71, p = 0.002) were protective factors against frailty. CONCLUSIONS: In Vietnam, the prevalence of frailty in older outpatients was 28%, though not significantly different between urban and rural areas. Older age, being underweight and limitations in functional status can increase the odds of frailty, but higher education and productive work can reduce the odds of frailty.


Assuntos
Fragilidade , Atividades Cotidianas , Idoso , Estudos Transversais , Feminino , Idoso Fragilizado , Fragilidade/diagnóstico , Fragilidade/epidemiologia , Avaliação Geriátrica , Humanos , Prevalência , Magreza/complicações , Magreza/diagnóstico , Magreza/epidemiologia
18.
Gels ; 8(6)2022 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-35735725

RESUMO

Ionogels are solid polymer gel networks loaded with ionic liquid (IL) percolating throughout each other, giving rise to ionically conducting solid electrolytes. They combine the mechanical properties of polymer networks with the ionic conductivity, non-volatility, and non-flammability of ILs. In the frame of their applications in electrochemical-based flexible electronics, ionogels are usually subjected to repeated deformation, making them susceptible to damage. It appears critical to devise a simple and effective strategy to improve their durability and lifespan by imparting them with healing ability through vitrimer chemistry. In this work, we report the original in situ synthesis of polythioether (PTE)-based vitrimer ionogels using fast photopolymerization through thiol-acrylate Michael addition. PTE-based vitrimer was prepared with a constant amount of the trithiol crosslinker and varied proportions of static dithiol spacers and dynamic chain extender BDB containing dynamic exchangeable boronic ester groups. The dynamic ionogels were prepared using 50 wt% of either 1-Ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl) imide or 1-Ethyl-3-methylimidazolium trifluoromethanesulfonate, both of which were selected for their high ionic conductivity. They are completely amorphous (Tg below -30 °C), suggesting they can be used at low temperatures. They are stretchable with an elongation at break around 60%, soft with Young's modulus between 0.4 and 0.6 MPa, and they have high ionic conductivities for solid state electrolytes in the order of 10-4 S·cm-1 at room temperature. They display dynamic properties typical of the vitrimer network, such as stress relaxation and healing, retained despite the large quantity of IL. The design concept illustrated in this work further enlarges the library of vitrimer ionogels and could potentially open a new path for the development of more sustainable, flexible electrochemical-based electronics with extended service life through repair or reprocessing.

19.
Science ; 376(6592): 502-507, 2022 04 29.
Artigo em Inglês | MEDLINE | ID: mdl-35482868

RESUMO

The human somatosensory network relies on ionic currents to sense, transmit, and process tactile information. We investigate hydrogels that similarly transduce pressure into ionic currents, forming a piezoionic skin. As in rapid- and slow-adapting mechanoreceptors, piezoionic currents can vary widely in duration, from milliseconds to hundreds of seconds. These currents are shown to elicit direct neuromodulation and muscle excitation, suggesting a path toward bionic sensory interfaces. The signal magnitude and duration depend on cationic and anionic mobility differences. Patterned hydrogel films with gradients of fixed charge provide voltage offsets akin to cell potentials. The combined effects enable the creation of self-powered and ultrasoft piezoionic mechanoreceptors that generate a charge density four to six orders of magnitude higher than those of triboelectric and piezoelectric devices.


Assuntos
Hidrogéis , Mecanorreceptores , Humanos , Fenômenos Mecânicos , Pele , Tato/fisiologia
20.
Materials (Basel) ; 15(1)2021 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-35009162

RESUMO

Nowadays, thermal regulation of the indoor environment is mandatory to reduce greenhouse gas emissions. The incorporation of Phase Change Materials (PCMs) and especially solid-solid PCMs (s/s PCMs) into building materials can be a major step forward in reducing energy consumption. Such materials are used for their high latent heat to save and release heat during phase change. To integrate these products in the fabrication of cementitious materials, it is essential to predict their influence on the rheological behaviour of construction materials. In this work, rheological measurements were carried out on composite suspensions made of cement or mortar plus s/s PCMs. Results showed that the fitting of the Herschel-Bulkley model with a constant value of flow exponent was reliable. The s/s PCMs influenced the consistency and the yield strength values, with the yield strength value being only slightly affected. The adaptation of an existing viscosity model is proposed to predict the consistency value of suspensions. Finally, an innovative approach to predict the flow behaviour is proposed and we highlight the research needs to mainstream the use of s/s PCMs in construction materials.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA