Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 92(5): 907-914, 2018 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-29368394

RESUMO

OBJECTIVES: We assess the mid-term outcomes of ultrathin biodegradable polymer double stenting using a very minimal crushing (Nano-Crush) technique in large complex coronary bifurcation. BACKGROUND: Complex bifurcations have been suggested to be better approached by a planned double stent technique. METHODS: Two hundred and five consecutive patients (107 males and 98 females) referred for large complex coronary bifurcation percutaneous coronary interventions were enrolled. The technique was also evaluated by both a bench test with a silicon tubes phantom resembling a coronary bifurcation and a computed fluid dynamic (CFD) analysis. RESULTS: Left main bifurcation accounted for 40.9% of cases (84 patients). Mean angles between main branch (MB) and side branch (SB) were 63.6 ± 21.3°. SB intravascular ultrasound-calculated MSA was 5.6 ± 1.5 mm2 . Clinical follow-up was available for 100% of patients and at a mean follow-up of 16.2 ± 6.7 months 8 deaths, all due to cardiovascular reason, (3.9%, 4 patients for stroke, two for heart failure, one after surgical aortic valve substitution, and one after acute massive pulmonary embolism) and no presumptive stent thrombosis or target vessel induced ischemia were observed. Angiographic follow-up was available in 108 patients (52.7%) and showed a very low significant restenosis (5 patients, 4.6%). Bench study and CFD evaluation suggested a complete coverage of the SB ostium with a very high strut-free area at the SB. CONCLUSIONS: The revascularization of complex large coronary bifurcation disease using the Nano-crush technique appeared promising thanks to the favorable fluid dynamic profile, complete coverage of the SD ostium, and very small metal amount at the carina.


Assuntos
Implantes Absorvíveis , Angioplastia Coronária com Balão/instrumentação , Doença da Artéria Coronariana/terapia , Stents , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/mortalidade , Simulação por Computador , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Doença da Artéria Coronariana/fisiopatologia , Circulação Coronária , Feminino , Humanos , Hidrodinâmica , Masculino , Teste de Materiais , Modelos Anatômicos , Modelos Cardiovasculares , Desenho de Prótese , Sistema de Registros , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA