RESUMO
PURPOSE: To evaluate the effect of vardenafil on renal function after renal ischemia-reperfusion (IR) injury (IRI) in a rat model. MATERIALS AND METHODS: Seventy-one Wistar rats were divided into 7 groups including (1) a vehicle-treated group, (2) a vehicle pretreated-IR group, (3-6) vardenafil pretreated-IR groups in doses of 0.02, 0.2, 2 and 20 µg/kg, respectively, (7) a group of IR followed by treatment with 2 µg/kg of vardenafil. Vardenafil or vehicle solution was administered one hour before unilateral nephrectomy and the induction of 45 min of ischemia on the contralateral kidney by clamping of renal pedicle. Four hours of reperfusion were allowed after renal ischemia. Studied parameters were serum creatinine, fractional excretion of sodium (FENa), and histological evaluation of renal specimens. In addition, renal tissue cGMP levels, ERK1/2 phosphorylation as well as renal function by renal scintigraphy were also evaluated. RESULTS: Administration of vardenafil before the induction of ischemia resulted in a significant reduction in creatinine and FENa levels as well as in less histological lesions observed in treated kidneys in comparison with the vehicle-treated group. The underlying mechanism of cytoprotection was cGMP depended and involved the phosphorylation of ERK proteins. Renal scintigraphy confirmed that PDE5 inhibition attenuates renal IRI. CONCLUSIONS: Vardenafil attenuates renal IRI. Based on similar results from relevant studies on other PDE-5 inhibitors in renal and cardiac IRI, it can be assumed that all PDE-5 inhibitors share a common mechanism of cytoprotection.
Assuntos
Imidazóis/uso terapêutico , Precondicionamento Isquêmico/métodos , Rim/irrigação sanguínea , Inibidores da Fosfodiesterase 5/uso terapêutico , Piperazinas/uso terapêutico , Traumatismo por Reperfusão/prevenção & controle , Animais , GMP Cíclico/fisiologia , Imidazóis/farmacologia , Rim/fisiologia , Sistema de Sinalização das MAP Quinases/efeitos dos fármacos , Sistema de Sinalização das MAP Quinases/fisiologia , Masculino , Modelos Animais , Inibidores da Fosfodiesterase 5/farmacologia , Piperazinas/farmacologia , Ratos , Ratos Wistar , Traumatismo por Reperfusão/fisiopatologia , Sulfonas/farmacologia , Sulfonas/uso terapêutico , Fatores de Tempo , Resultado do Tratamento , Triazinas/farmacologia , Triazinas/uso terapêutico , Dicloridrato de VardenafilaRESUMO
PURPOSE: GATE is a Monte Carlo simulation toolkit based on the Geant4 package, widely used for many medical physics applications, including SPECT and PET image simulation and more recently CT image simulation and patient dosimetry. The purpose of the current study was to calculate dose point kernels (DPKs) using GATE, compare them against reference data, and finally produce a complete dataset of the total DPKs for the most commonly used radionuclides in nuclear medicine. METHODS: Patient-specific absorbed dose calculations can be carried out using Monte Carlo simulations. The latest version of GATE extends its applications to Radiotherapy and Dosimetry. Comparison of the proposed method for the generation of DPKs was performed for (a) monoenergetic electron sources, with energies ranging from 10 keV to 10 MeV, (b) beta emitting isotopes, e.g., (177)Lu, (90)Y, and (32)P, and (c) gamma emitting isotopes, e.g., (111)In, (131)I, (125)I, and (99m)Tc. Point isotropic sources were simulated at the center of a sphere phantom, and the absorbed dose was stored in concentric spherical shells around the source. Evaluation was performed with already published studies for different Monte Carlo codes namely MCNP, EGS, FLUKA, ETRAN, GEPTS, and PENELOPE. A complete dataset of total DPKs was generated for water (equivalent to soft tissue), bone, and lung. This dataset takes into account all the major components of radiation interactions for the selected isotopes, including the absorbed dose from emitted electrons, photons, and all secondary particles generated from the electromagnetic interactions. RESULTS: GATE comparison provided reliable results in all cases (monoenergetic electrons, beta emitting isotopes, and photon emitting isotopes). The observed differences between GATE and other codes are less than 10% and comparable to the discrepancies observed among other packages. The produced DPKs are in very good agreement with the already published data, which allowed us to produce a unique DPKs dataset using GATE. The dataset contains the total DPKs for (67)Ga, (68)Ga, (90)Y, (99m)Tc, (111)In, (123)I, (124)I, (125)I, (131)I, (153)Sm, (177)Lu (186)Re, and (188)Re generated in water, bone, and lung. CONCLUSIONS: In this study, the authors have checked GATE's reliability for absorbed dose calculation when transporting different kind of particles, which indicates its robustness for dosimetry applications. A novel dataset of DPKs is provided, which can be applied in patient-specific dosimetry using analytical point kernel convolution algorithms.
Assuntos
Método de Monte Carlo , Medicina Nuclear/instrumentação , Medicina Nuclear/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Simulação por Computador , Elétrons , Humanos , Isótopos , Fótons , Tomografia por Emissão de Pósitrons/métodos , Radioimunoterapia/métodos , Radiometria/métodos , Software , Tomografia Computadorizada de Emissão de Fóton Único/métodosRESUMO
PURPOSE: Optical coherence tomography (OCT) is a catheter-based imaging method that employs near-infrared light to produce high-resolution cross-sectional intravascular images. The authors propose a segmentation technique for automatic lumen area extraction and stent strut detection in intravascular OCT images for the purpose of quantitative analysis of neointimal hyperplasia (NIH). METHODS: A clinical dataset of frequency-domain OCT scans of the human femoral artery was analyzed. First, a segmentation method based on the Markov random field (MRF) model was employed for lumen area identification. Second, textural and edge information derived from local intensity distribution and continuous wavelet transform (CWT) analysis were integrated to extract the inner luminal contour. Finally, the stent strut positions were detected via the introduction of each strut wavelet response across scales into a feature extraction and classification scheme in order to optimize the strut position detection. RESULTS: The inner lumen contour and the position of stent strut were extracted with very high accuracy. Compared with manual segmentation by an expert vascular physician the automatic segmentation had an average overlap value of 0.937 ± 0.045 for all OCT images included in the study. The strut detection accuracy had an area under the curve (AUC) value of 0.95, together with sensitivity and specificity average values of 0.91 and 0.96, respectively. CONCLUSIONS: A robust automatic segmentation technique integrating textural and edge information for vessel lumen border extraction and strut detection in intravascular OCT images was designed and presented. The proposed algorithm may be employed for automated quantitative morphological analysis of in-stent neointimal hyperplasia.
Assuntos
Algoritmos , Prótese Vascular , Artéria Femoral/patologia , Corpos Estranhos/diagnóstico , Reconhecimento Automatizado de Padrão/métodos , Stents , Tomografia de Coerência Óptica/métodos , Prótese Vascular/efeitos adversos , Artéria Femoral/cirurgia , Humanos , Hiperplasia/etiologia , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Neointima/diagnóstico , Neointima/etiologia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Stents/efeitos adversosRESUMO
Recent developments in image-guidance and device navigation, along with emerging robotic technologies, are rapidly transforming the landscape of interventional radiology (IR). Future state-of-the-art IR procedures may include real-time three-dimensional imaging that is capable of visualizing the target organ, interventional tools, and surrounding anatomy with high spatial and temporal resolution. Remote device actuation is becoming a reality with the introduction of novel magnetic-field enabled instruments and remote robotic steering systems. Robots offer several degrees of freedom and unprecedented accuracy, stability, and dexterity during device navigation, propulsion, and actuation. Optimization of tracking and navigation of interventional tools inside the human body will be critical in converting IR suites into the minimally invasive operating theaters of the future with increased safety and unsurpassed therapeutic efficacy. In the not too distant future, individual image guidance modalities and device tracking methods could merge into autonomous, multimodality, multiparametric platforms that offer real-time data of anatomy, morphology, function, and metabolism along with on-the-fly computational modeling and remote robotic actuation. The authors provide a concise overview of the latest developments in image guidance and device navigation, while critically envisioning what the future might hold for 2020 IR procedures.
Assuntos
Radiologia Intervencionista/instrumentação , Radiologia Intervencionista/métodos , Diagnóstico por Imagem , HumanosRESUMO
PURPOSE: The aim of the present study was the evaluation and optimization of radiation dose to the ovaries (D) in hysterosalpingography (HSG). METHODS: The study included a phantom study and a clinical one. In the phantom study, we evaluated imaging results for different geometrical setups and irradiation conditions. In the clinical study, 34 women were assigned into three different fluoroscopy modes and D was estimated with direct cervical TLD measurements. RESULTS: In the phantom study, we used a source-to-image-distance (SID) of 110 cm and a field diagonal of 48 cm, and thus decreased air KERMA rate (KR) by 19% and 70%, respectively, for beam filtration: 4 mm Al and 0.9 mm Cu (Low dose). The least radiation exposure was accomplished by using the 3.75 pps fluoroscopy mode in conjunction with beam filtration: Low dose. In the clinical study, D normalized to 50 s of fluoroscopy time with a 3.75 pps fluoroscopy mode reached a value of 0.45 ± 0.04 mGy. Observers' evaluation of diagnostic image quality did not significantly differ for the three different modes of acquisition that were compared. CONCLUSIONS: Digital spot radiographs could be omitted in modern flat panel systems during HSG. Fluoroscopy image acquisitions in a modern flat panel unit at 3.75 pps and a beam filtration of 4 mm Al and 0.9 mm Cu demonstrate acceptable image quality with an average D equal to 0.45 mGy. This value is lower compared to the studied literature. For these reasons, the proposed method may be recommended for routine HSG examination in order to limit radiation exposure to the ovaries.
Assuntos
Histerossalpingografia/instrumentação , Ovário/diagnóstico por imagem , Doses de Radiação , Proteção Radiológica/métodos , Radiometria/métodos , Ecrans Intensificadores para Raios X , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Histerossalpingografia/métodos , Ovário/efeitos da radiaçãoRESUMO
The use of small animal models in basic and preclinical sciences constitutes an integral part of testing new pharmaceutical agents prior to commercial translation to clinical practice. Whole-body small animal imaging is a particularly elegant and cost-effective experimental platform for the timely validation and commercialization of novel agents from the bench to the bedside. Biomedical imaging is now listed along with genomics, proteomics, and metabolomics as an integral part of biological and medical sciences. Miniaturized versions of clinical diagnostic modalities, including but not limited to microcomputed tomography, micromagnetic resonance tomography, microsingle-photon-emission tomography, micropositron-emission tomography, optical imaging, digital angiography, and ultrasound, have all greatly improved our investigative abilities to longitudinally study various experimental models of human disease in mice and rodents. After an exhaustive literature search, the authors present a concise and critical review of in vivo small animal imaging, focusing on currently available modalities as well as emerging imaging technologies on one side and molecularly targeted contrast agents on the other. Aforementioned scientific topics are analyzed in the context of cancer angiogenesis and innovative antiangiogenic strategies under-the-way to the clinic. Proposed hybrid approaches for diagnosis and targeted site-specific therapy are highlighted to offer an intriguing glimpse of the future.
Assuntos
Diagnóstico por Imagem/métodos , Animais , Meios de Contraste , Diagnóstico por Imagem/tendências , Humanos , Microbolhas , Fenômenos Ópticos , Traçadores RadioativosRESUMO
Many empirical studies have demonstrated the exquisite sensitivity of both traditional and novel statistical and machine intelligence algorithms to the method of background adjustment used to analyze microarray datasets. In this paper we develop a statistical framework that approaches background adjustment as a classic stochastic inverse problem, whose noise characteristics are given in terms of Maximum Entropy distributions. We derive analytic closed form approximations to the combined problem of estimating the magnitude of the background in microarray images and adjusting for its presence. The proposed method reduces standardized measures of log expression variability across replicates in situations of known differential and non-differential gene expression without increasing the bias. Additionally, it results in computationally efficient procedures for estimation and learning based on sufficient statistics and can filter out spot measures with intensities that are numerically close to the background level resulting in a noise reduction of about 7%.
Assuntos
Entropia , Análise de Sequência com Séries de Oligonucleotídeos/métodos , Algoritmos , Expressão Gênica , Modelos EstatísticosRESUMO
BACKGROUND: The aim of our study was to determine the impact of CYP3A5*1 and CYP3A5*3 on the kinetics of tacrolimus in renal transplant recipients. MATERIAL AND METHODS: Forty kidney recipients were selected to participate. Maintenance scheme consisted of tacrolimus, a purine inhibitor and a steroid. CYP3A5 genotyping was performed with PCR and RFLP. Pharmacokinetic model was developed with Linear Regression and General Linear Model repeated measures approach. The impact of sex, CYP3A5*1 allele, age at transplantation, hepatic and renal function on tacrolimus kinetics was examined. RESULTS: The frequency of CYP3A5*3/*3 and CYP3A5*1/*3 genotype was 35/40 and 5/40, respectively. No CYP3A5*1/*1 was detected. CYP3A5*1 variant was associated with significant lower TAC dose adjusted concentration at 3, 6, 12 and 36 months after transplantation. Hepatic and renal function showed a significant effect on tacrolimus dose adjusted concentration 3 months after transplantation (p=0.000 and 0.028, respectively). Sex did not show a significant impact on tacrolimus kinetics. Carriers of CYP3A5*1 allele had lower predicted measures for tacrolimus dose adjusted concentration and higher predicted measures for volume of distribution. CONCLUSION: We proved that CYP3A5*1 carriers need higher tacrolimus dose than CYP3A5*3 homozygotes to achieve the target blood concentration.
Assuntos
Transplante de Rim , Rim/efeitos dos fármacos , Tacrolimo/farmacocinética , Adulto , Alelos , Citocromo P-450 CYP3A , Feminino , Genótipo , Homozigoto , Humanos , Testes de Função Renal , Masculino , Pessoa de Meia-Idade , Reação em Cadeia da Polimerase , Polimorfismo de Fragmento de Restrição , Esteroides/farmacocinética , Tacrolimo/sangueRESUMO
BACKGROUND: Compared with angiogenesis, arteriogenesis is a distinct process based on the remodeling and maturation of pre-existing arterioles into large conductance arteries. Therapeutic angiogenesis has been proposed as a potential treatment for ischemic atherosclerotic diseases. Since a variety of angiogenic factors have been tested with inconsistent so far clinical results, the challenge remains in identifying the factor(s) that will stimulate functional neovascularization. Thrombin has been reported to play a pivotal role in the initiation of angiogenesis by regulating and organizing a network of angiogenic mediators. Also, it was recently demonstrated that thrombin is a potent anti-apoptotic factor for endothelial cells, providing evidence on a potential role of thrombin in vascular protection and maintenance of vessel integrity. Based on these observations, we hypothesized that thrombin may promote the development of mature functional blood vessels. METHODS: Seventy-four (n=74) rabbits underwent bilateral femoral artery surgical excision. On the 20th postsurgical day increasing doses of VEGF or bFGF or thrombin were injected in one ischemic limb per rabbit and an equal volume of normal saline to the contralateral control limbs. Quantification of newly developed collateral vessels (diameter >500 mum) was performed by transauricular intra-arterial subtraction angiography. Computerized quantitative analysis of collateral vessels in angiography images was based on the concept of multiscale structural tensor. Perfusion analysis of an in vivo dynamic computed tomography study was performed to investigate hemodynamic recovery of the distal ischemic limbs. Tissue perfusion analysis was performed with the semiquantitative slope methodology, which focuses on the first-pass arterial phase. RESULTS: A single administration of thrombin exhibited a dose-dependent increase of arteriogenic outcome. Thrombin at 5000 IU induced a 30.2 +/- 7.4% (P < 0.05) increase of total collateral area and length. Both VEGF and bFGF were without any significant effect at the concentrations used. Functional estimation of limb perfusion showed a statistically significant increase of blood flow recovery only for thrombin. The semiquantitative slope method perfusion score differed significantly in the 5000 IU thrombin treated limbs (5.7 +/- 0.3 vs 5.0 +/- 0.3 in control ischemic limbs; P < .05), and was not significantly inferior from the score of normal nonoperated limbs (6.5 +/- 0.3) suggesting a trend towards hemodynamic recovery of distal limb perfusion. CONCLUSIONS: In a rabbit hindlimb ischemia model, thrombin promoted the formation of large collateral vessels and improved the perfusion of distal ischemic tissue. These results provide new insights in understanding the involvement of thrombin in vascular formation and point to a novel role of thrombin in arteriogenesis.
Assuntos
Indutores da Angiogênese/metabolismo , Hemodinâmica , Isquemia/metabolismo , Músculo Esquelético/irrigação sanguínea , Neovascularização Fisiológica , Trombina/metabolismo , Indutores da Angiogênese/administração & dosagem , Angiografia Digital , Animais , Artérias/crescimento & desenvolvimento , Circulação Colateral , Modelos Animais de Doenças , Relação Dose-Resposta a Droga , Fator 2 de Crescimento de Fibroblastos/administração & dosagem , Hemodinâmica/efeitos dos fármacos , Membro Posterior , Injeções Intramusculares , Isquemia/diagnóstico por imagem , Isquemia/tratamento farmacológico , Isquemia/fisiopatologia , Masculino , Neovascularização Fisiológica/efeitos dos fármacos , Imagem de Perfusão/métodos , Coelhos , Recuperação de Função Fisiológica , Fluxo Sanguíneo Regional , Trombina/administração & dosagem , Tomografia Computadorizada por Raios X , Fator A de Crescimento do Endotélio Vascular/administração & dosagemRESUMO
In the rapidly advancing field of flow cytometry, methodologies facilitating automated clinical decision support are increasingly needed. In the case of B-chronic lymphocytic leukemia (B-CLL), discrimination of the various subpopulations of blood cells is an important task. In this work, our objective is to provide a useful paradigm of computer-based assistance in the domain of flow-cytometric data analysis by proposing a Bayesian methodology for flow cytometry clustering. Using Bayesian clustering, we replicate a series of (unsupervised) data clustering tasks, usually performed manually by the expert. The proposed methodology is able to incorporate the expert's knowledge, as prior information to data-driven statistical learning methods, in a simple and efficient way. We observe almost optimal clustering results, with respect to the expert's gold standard. The model is flexible enough to identify correctly non canonical clustering structures, despite the presence of various abnormalities and heterogeneities in data; it offers an advantage over other types of approaches that apply hierarchical or distance-based concepts.
Assuntos
Teorema de Bayes , Análise por Conglomerados , Citometria de Fluxo , Leucemia Linfocítica Crônica de Células B/diagnóstico , Biomarcadores Tumorais/sangue , Interpretação Estatística de Dados , Diagnóstico por Computador , Humanos , Redes Neurais de ComputaçãoRESUMO
BACKGROUND: The integration of biomedical information is essential for tackling medical problems. We describe a data model in the domain of flow cytometry (FC) allowing for massive management, analysis and integration with other laboratory and clinical information. The paper is concerned with the proper translation of the Flow Cytometry Standard (FCS) into a relational database schema, in a way that facilitates end users at either doing research on FC or studying specific cases of patients undergone FC analysis RESULTS: The proposed database schema provides integration of data originating from diverse acquisition settings, organized in a way that allows syntactically simple queries that provide results significantly faster than the conventional implementations of the FCS standard. The proposed schema can potentially achieve up to 8 orders of magnitude reduction in query complexity and up to 2 orders of magnitude reduction in response time for data originating from flow cytometers that record 256 colours. This is mainly achieved by managing to maintain an almost constant number of data-mining procedures regardless of the size and complexity of the stored information. CONCLUSION: It is evident that using single-file data storage standards for the design of databases without any structural transformations significantly limits the flexibility of databases. Analysis of the requirements of a specific domain for integration and massive data processing can provide the necessary schema modifications that will unlock the additional functionality of a relational database.
Assuntos
Algoritmos , Sistemas de Gerenciamento de Base de Dados , Bases de Dados Factuais , Citometria de Fluxo/métodos , Armazenamento e Recuperação da Informação/métodos , Software , Interface Usuário-Computador , Integração de SistemasRESUMO
Molecular imaging (MI) constitutes a recently developed approach of imaging, where modalities and agents have been reinvented and used in novel combinations in order to expose and measure biologic processes occurring at molecular and cellular levels. It is an approach that bridges the gap between modalities acquiring data from high (e.g., computed tomography, magnetic resonance imaging, and positron-emitting isotopes) and low (e.g., PCR, microarrays) levels of a biological organization. While data integration methodologies will lead to improved diagnostic and prognostic performance, interdisciplinary collaboration, triggered by MI, will result in a better perception of the underlying biological mechanisms. Toward the development of a unifying theory describing these mechanisms, medical physicists can formulate new hypotheses, provide the physical constraints bounding them, and consequently design appropriate experiments. Their new scientific and working environment calls for interventions in their syllabi to educate scientists with enhanced capabilities for holistic views and synthesis.
Assuntos
Diagnóstico por Imagem/métodos , Física Médica/métodos , Biologia Molecular/métodos , Física Nuclear/métodos , Estatística como Assunto , Animais , Diagnóstico por Imagem/tendências , Marcadores Genéticos , Genômica/métodos , Genômica/tendências , Física Médica/tendências , Humanos , Aplicações da Informática Médica , Análise em Microsséries/métodos , Análise em Microsséries/tendências , Biologia Molecular/tendências , Física Nuclear/tendênciasRESUMO
The present study reports on computational fluid dynamics in the case of severe renal artery stenosis (RAS). An anatomically realistic model of a renal artery was reconstructed from CT scans, and used to conduct CFD simulations of blood flow across RAS. The recently developed shear stress transport (SST) turbulence model was pivotally applied in the simulation of blood flow in the region of interest. Blood flow was studied in vivo under the presence of RAS and subsequently in simulated cases before the development of RAS, and after endovascular stent implantation. The pressure gradients in the RAS case were many orders of magnitude larger than in the healthy case. The presence of RAS increased flow resistance, which led to considerably lower blood flow rates. A simulated stent in place of the RAS decreased the flow resistance at levels proportional to, and even lower than, the simulated healthy case without the RAS. The wall shear stresses, differential pressure profiles, and net forces exerted on the surface of the atherosclerotic plaque at peak pulse were shown to be of relevant high distinctiveness, so as to be considered potential indicators of hemodynamically significant RAS.
Assuntos
Hemodinâmica , Modelos Biológicos , Obstrução da Artéria Renal/fisiopatologia , Artéria Renal/anatomia & histologia , Artéria Renal/fisiopatologia , Simulação por Computador , Humanos , Modelos Anatômicos , Reprodutibilidade dos TestesRESUMO
The purpose of our study was to develop a user-independent computerized tool for the automated segmentation and quantitative assessment of in vivo-acquired digital subtraction angiography (DSA) images. Vessel enhancement was accomplished based on the concept of image structural tensor. The developed software was tested on a series of DSA images acquired from one animal and two human angiogenesis models. Its performance was evaluated against manually segmented images. A receiver's operating characteristic curve was obtained for every image with regard to the different percentages of the image histogram. The area under the mean curve was 0.89 for the experimental angiogenesis model and 0.76 and 0.86 for the two clinical angiogenesis models. The coordinates of the operating point were 8.3% false positive rate and 92.8% true positive rate for the experimental model. Correspondingly for clinical angiogenesis models, the coordinates were 8.6% false positive rate and 89.2% true positive rate and 9.8% false positive rate and 93.8% true positive rate, respectively. A new user-friendly tool for the analysis of vascular networks in DSA images was developed that can be easily used in either experimental or clinical studies. Its main characteristics are robustness and fast and automatic execution.
Assuntos
Angiografia Digital/métodos , Processamento de Imagem Assistida por Computador/métodos , Animais , Meios de Contraste , Modelos Animais de Doenças , Reações Falso-Negativas , Reações Falso-Positivas , Membro Posterior/irrigação sanguínea , Membro Posterior/diagnóstico por imagem , Humanos , Neovascularização Patológica/diagnóstico por imagem , Distribuição Normal , Variações Dependentes do Observador , Curva ROC , Coelhos , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Software , Artéria Subclávia/diagnóstico por imagem , Ácidos Tri-IodobenzoicosRESUMO
BACKGROUND AND PURPOSE: Recent reports concerning coronary, carotid, and femoral vasculature have proposed the use of drug-eluting metal stents (MS) to improve clinical and angiographic outcomes. Based on these reports, we used paclitaxel-eluting MS within an animal renal artery lumen and compared the results with those using a bare-metal stent. MATERIALS AND METHODS: The experimental model in this study was the female pig renal artery. Ten pigs with weights ranging from 25 to 30 kg were used. Twenty stents were placed, two in each animal. The MS placement was randomly performed in either the right or left renal artery of each animal. In 10 arteries, a 3.5 x 18 mm R-stent (group A) was placed; in the remaining 10 arteries, a 3 x 32 mm paclitaxel-eluting coronary stent (T-stent, group B) was inserted. Patency was estimated with the use of digital subtraction angiography, CT angiography, and virtual endoscopy at 24 hours and 1 month poststent placement. RESULTS: The positioning of the MS was successful in all cases. The initial angiographic result was maintained 24 hours after the intervention. No stent migration was seen, except for one paclitaxel stent that was acutely occluded. The one-month patency rate, as demonstrated by angiography, CT angiography, and virtual endoscopy, was 70% (8 arteries) in group A and 90% (9 arteries) in group B. The thickness of the endothelium and of the muscular coat was statistically significantly less in group B compared with group A (P = 0.0352 and P = 0.0046, respectively). CONCLUSION: These preliminary experimental study results suggest that the paclitaxel-eluting MS is more efficient than the bare-metal stent when used within the pig renal artery. Further experimental and clinical studies are necessary to validate our preliminary encouraging results.
Assuntos
Antineoplásicos Fitogênicos/farmacologia , Implante de Prótese Vascular/instrumentação , Materiais Revestidos Biocompatíveis , Paclitaxel/farmacologia , Obstrução da Artéria Renal/cirurgia , Stents , Angiografia , Angioscopia , Animais , Modelos Animais de Doenças , Feminino , Desenho de Prótese , Obstrução da Artéria Renal/diagnóstico por imagem , Suínos , Resultado do TratamentoRESUMO
Technological breakthroughs have advanced the temporal and spatial resolutions of diagnostic imaging, and 3 dimensional (3-D) reconstruction techniques have been introduced into everyday clinical practice. Virtual endoscopy (VE) is a non-invasive technique that amplifies the perception of cross-sectional images in the 3-D space, providing precise spatial relationships of pathological regions and their surrounding structures. A variety of computer algorithms can be used to generate 3-D images, taking advantage of the information inherent in either spiral computed tomography or magnetic resonance imaging (MRI). VE images enable endoluminal navigation through hollow organs, thus simulating conventional endoscopy. Several clinical studies have validated the diagnostic utility of virtual cystoscopy, which has high sensitivity and specificity rates in the detection of bladder tumor. Published experience in the virtual exploration of the renal pelvis, ureter and urethra is encouraging but still scarce. VE is a safe, non-invasive method that could be applied in the long-term follow-up of patients with ureteropelvic junction obstruction, urinary bladder tumors and ureteral and/or urethral strictures. Its principal limitations are the inability to provide biopsy tissue specimens for histopathologic examination and the associated ionizing radiation hazards (unless MRI is used). However, in the case of endoluminal stenosis or obstruction, VE permits virtual endoluminal navigation both cephalad and caudal to the stenotic segment. To conclude, VE provides a less invasive method of evaluating the urinary tract, especially for clinicians who are less familiar with cross-sectional imaging than radiologists.
Assuntos
Endoscopia/métodos , Tomografia Computadorizada por Raios X/métodos , Doenças Urológicas/diagnóstico , Cistoscopia/métodos , Humanos , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Sensibilidade e Especificidade , Doenças Ureterais/diagnóstico , Doenças Uretrais/diagnósticoRESUMO
BACKGROUND: Minimal glucose infusions are known to entrain insulin oscillations in patients with normal glucose tolerance (NGT) but not in patients with type 2 diabetes (T2D). OBJECTIVES: To investigate whether weight loss after a version of biliopancreatic diversion (BPD) can restore the glucose entrainment of high-frequency insulin oscillations in morbidly obese NGT or T2D patients. SETTING: University Hospital, Greece. METHODS: We prospectively studied 9 NGT controls (body mass index [BMI] 23.3±1.6 kg/m2), 9 obese NGT patients (BMI 51.1±12.7 kg/m2), and 9 obese T2D patients (BMI 56.8±11.6 kg/m2). Patients were studied before and 1.5 years after BPD. Insulin was sampled every minute for 90 minutes. Glucose (6 mg/kg weight) was infused every 10 minutes for 1 minute. Regularity of insulin pulses was estimated by autocorrelation analysis, spectral analysis, approximate entropy/sample entropy (ApEn/SampEn), and insulin pulsatility by deconvolution analysis. RESULTS: Postoperatively, glucose and insulin concentrations of NGT and T2D patients decreased to control levels and BMI to 31.3±6.3 for NGT patients and 34.9±9.9 kg/m2 for T2D patients. Preoperatively, glucose entrainment was absent in all T2D and in 4 NGT patients as assessed with spectral analysis and in 8 and 4, respectively, as assessed with autocorrelation and deconvolution analysis. Postoperatively, it was restored to normal in all patients. ApEn/SampEn decreased significantly only in the T2D group postoperatively. CONCLUSION: BPD restores the glucose entrainment of high-frequency insulin oscillations in obese NGT and T2D patients after marked weight loss and normalizes glucose levels and insulin sensitivity, thus demonstrating recovery of ß-cell glucose sensing.
Assuntos
Desvio Biliopancreático , Diabetes Mellitus Tipo 2/sangue , Insulina/metabolismo , Obesidade Mórbida/sangue , Adulto , Glicemia/metabolismo , Índice de Massa Corporal , Estudos de Casos e Controles , Diabetes Mellitus Tipo 2/cirurgia , Jejum/sangue , Feminino , Glucose/administração & dosagem , Glucose/farmacologia , Teste de Tolerância a Glucose , Humanos , Infusões Intravenosas , Resistência à Insulina/fisiologia , Células Secretoras de Insulina/fisiologia , Masculino , Obesidade Mórbida/cirurgia , Cuidados Pós-Operatórios , Estudos Prospectivos , Edulcorantes/administração & dosagem , Edulcorantes/farmacologia , Redução de Peso/fisiologiaRESUMO
Our purpose was to describe a technique for simulating the surgical view of ruptured intracranial aneurysms, using volume-rendering techniques in spiral computed tomography (CT) angiography data. The 3D (three-dimensional) rendered images were assessed by a team consisted of four radiologists, one neurosurgeon and one medical physicist. The resultant 'surgical view' image was standardized in space using a three-dimensional coordinate system, which allowed for its reproduction in the operating theatre. The surgical views are a potentially useful tool for the surgical planning of intracranial aneurysms.
Assuntos
Aneurisma Roto/diagnóstico por imagem , Angiografia Cerebral/métodos , Imageamento Tridimensional , Aneurisma Intracraniano/diagnóstico por imagem , Tomografia Computadorizada Espiral , Adolescente , Adulto , Idoso , Aneurisma Roto/cirurgia , Feminino , Humanos , Aneurisma Intracraniano/cirurgia , Masculino , Pessoa de Meia-IdadeRESUMO
Image registration of multimodality images is an essential task in numerous applications in three-dimensional medical image processing. Medical diagnosis can benefit from the complementary information in different modality images. Surface-based registration techniques, while still widely used, were succeeded by volume-based registration algorithms that appear to be theoretically advantageous in terms of reliability and accuracy. Several applications of such algorithms for the registration of CT-MRI, CT-PET, MRI-PET, and SPECT-MRI images have emerged in the literature, using local optimization techniques for the matching of images. Our purpose in this work is the development of automatic techniques for the registration of real CT and SPECT images, based on either surface- or volume-based algorithms. Optimization is achieved using genetic algorithms that are known for their robustness. The two techniques are compared against a well-established method, the Iterative Closest Point-ICP. The correlation coefficient was employed as an independent measure of spatial match, to produce unbiased results. The repeated measures ANOVA indicates the significant impact of the choice of registration method on the magnitude of the correlation (F = 4.968, p = 0.0396). The volume-based method achieves an average correlation coefficient value of 0.454 with a standard deviation of 0.0395, as opposed to an average of 0.380 with a standard deviation of 0.0603 achieved by the surface-based method and an average of 0.396 with a standard deviation equal to 0.0353 achieved by ICP. The volume-based technique performs significantly better compared to both ICP (p<0.05, Neuman Keuls test) and the surface-based technique (p<0.05, Neuman-Keuls test). Surface-based registration and ICP do not differ significantly in performance.
Assuntos
Encéfalo/patologia , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Encéfalo/diagnóstico por imagem , Neoplasias Encefálicas/diagnóstico , Humanos , Modelos EstatísticosRESUMO
INTRODUCTION: Cerebral CT angiography (CTA) is an established method applied to both the detection and treatment planning of intracranial aneurysms. The aim of our study was to compare CTA and digital subtraction angiography (DSA) findings with the surgical results mainly in patients with acute SAH and to evaluate the clinical usefulness of CTA. MATERIALS AND METHODS: During the last 2 years, 82 consecutive patients were admitted under clinical symptoms and signs suggestive of harboring an intracranial aneurysm. CT angiography performed immediately afterwards the plain CT, while DSA was performed within the first 48 h of admission. All aneurysms detected were confirmed during surgery or endovascular embolization. Repeat DSA was performed in all patients having both the initial CTA and the DSA 15 days after the onset of symptoms negative. CT angiograms and conventional angiographies were studied by a consensus of two radiologists for each technique, who performed aneurysm detection, morphological features characterization and evaluation of the technique. RESULTS: Surgical or/and endovascular treatment was performed in 45 patients and 53 aneurysms were confirmed. Using 3D-CT angiography, we detected 47 aneurysms in 42 patients. Conventional angiography depicted 43 aneurysms in 39 patients. The sensitivity of CTA for the detection of all aneurysms versus surgery was 88.7%, the specificity 100%, the positive predictive value (PPV) 100%, the negative predictive value (NPV) 80.7% and the accuracy 92.3%. Accordingly, the sensitivity of DSA was 87.8%, the specificity 98%, the PPV 97.7%, the NPV 89.1% and the accuracy 92.9%. Considering aneurysms > or =3 mm, CTA showed a sensitivity ranging from 93.3 to 100%, equal to that of DSA. CONCLUSION: Cerebral CT angiography has an equal sensitivity to DSA in the detection of intracranial aneurysms >3 mm. It has also 100% detection rate in AcoA and MCA bifurcation aneurysms, while some locations, like posterior communicating artery aneurysms, remain problematic. The delineating features of each aneurysm are better depicted with CTA due to 3D visualization. The use of digital subtraction angiography as a diagnostic tool can be limited in equivocal cases.