Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 51
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Clin Oral Investig ; 27(5): 2375-2384, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36640179

RESUMO

OBJECTIVES: To evaluate the diagnostic MRI compatibility of different fixed orthodontic retainers using a high-resolution 3D-sequence optimized for artifact reduction. MATERIALS AND METHODS: Maxillary and mandibular retainers made of five different materials were scanned in vitro and in vivo at 3 T MRI using an MSVAT-SPACE sequence. In vitro, artifact volumes were determined for all maxillary and mandibular retainers (AVmax; AVmand). In vivo, two independent observers quantified the extent of artifacts based on the visibility of 124 dental and non-dental landmarks using a five-point rating scale (1 = excellent, 2 = good, 3 = acceptable, 4 = poor, 5 = not visible). RESULTS: Rectangular-steel retainers caused the largest artifacts (AVmax/AVmand: 18,060/15,879 mm3) and considerable diagnostic impairment in vivo (mean landmark visibility score ± SD inside/outside the retainer areas: 4.8 ± 0.8/2.9 ± 1.6). Smaller, but diagnostically relevant artifacts were observed for twistflex steel retainers (437/6317 mm3, 3.1 ± 1.7/1.3 ± 0.7). All retainers made of precious-alloy materials produced only very small artifact volumes (titanium grade 1: 70/46 mm3, titanium grade 5: 47/35 mm3, gold: 23/21 mm3) without any impact on image quality in vivo (each retainer: visibility scores of 1.0 ± 0.0 for all landmarks inside and outside the retainer areas). CONCLUSIONS: In contrast to steel retainers, titanium and gold retainers are fully compatible for both head/neck and dental MRI when using MSVAT-SPACE. CLINICAL RELEVANCE: This study demonstrates that titanium and gold retainers do not impair the diagnostic quality of head/neck and dental MRI when applying an appropriate artifact-reduction technique. Steel retainers, however, are not suitable for dental MRI and can severely impair image quality in head/neck MRI of the oral cavity.


Assuntos
Contenções Ortodônticas , Titânio , Boca , Imageamento por Ressonância Magnética/métodos , Aço Inoxidável , Ouro
2.
Clin Oral Investig ; 26(11): 6765-6772, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35861757

RESUMO

OBJECTIVES: To prospectively assess the reliability and accuracy of high-resolution, dental MRI (dMRI) for endodontic working length (WL) measurements of premolars and molars under clinical conditions. MATERIALS AND METHODS: Three-Tesla dMRI was performed in 9 subjects who also had undergone cone-beam computed tomography (CBCT) (mean age: 47 ± 13.5 years). A total of 34 root canals from 12 molars (4/8, upper/lower jaw; 22 root canals) and 11 premolars (2/9 upper/lower jaw; 12 root canals) were included. CBCT and dMRI datasets were reconstructed to visualize the root canal in one single slice. Subsequently, two radiologists measured the root canal lengths in both modalities twice in blinded fashion. Reliability and accuracy for both modalities were assessed using intraclass correlation coefficients (ICCs) and Bland-Altman analysis, respectively. RESULTS: Reliability (intra-rater I/II; inter-rater) of dental MRI measurements was excellent and comparable to CBCT for premolars (0.993/0.900; 0.958 vs. 0.993/0.956; 0.951) and for molars (0.978/0.995; 0.986 vs. 0.992/0.996; 0.989). Bland-Altman analysis revealed a mean underestimation/bias (95% confidence interval) of dMRI measurements of 0.8 (- 1.44/3.05) mm for premolars and 0.4 (- 1.55/2.39) mm for molars. In up to 59% of the cases, the accuracy of dMRI for WL measurements was within the underestimation margin of 0 to 2 mm short of the apical foramen AF. CONCLUSIONS: In vivo demonstration and measurement of WL are feasible using dMRI. The reliability of measurements is high and equivalent to CBCT. Nonetheless, due to lower spatial resolution and longer acquisition time, the accuracy of dMRI is inferior to CBCT, impeding its current use for clinical treatment planning. CLINICAL RELEVANCE: dMRI is a promising radiation-free imaging technique. Its reliability for endodontic working length measurements is high, but its accuracy is not satisfactory enough yet.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Dente Molar , Humanos , Adulto , Pessoa de Meia-Idade , Dente Pré-Molar/diagnóstico por imagem , Projetos Piloto , Reprodutibilidade dos Testes , Tomografia Computadorizada de Feixe Cônico/métodos , Dente Molar/diagnóstico por imagem , Imageamento por Ressonância Magnética , Cavidade Pulpar/diagnóstico por imagem
3.
Eur Radiol ; 31(11): 8420-8428, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33914117

RESUMO

OBJECTIVES: To use magnetic resonance fingerprinting (MRF)-derived T1 and T2 values to differentiate gonadotroph from non-gonadotroph pituitary macroadenomas based on the 2017 World Health Organization classification of pituitary adenomas. METHODS: A total of 57 patients with suspected pituitary macroadenomas were enrolled for analyses in this study between May 2018 and January 2020. Conventional magnetic resonance imaging (MRI) and MRF were performed in all patients before surgery using a 3-T MRI scanner. MRF-derived T1 and T2 values were compared between the gonadotroph and non-gonadotroph pituitary macroadenomas using a Mann-Whitney U test. The Knosp classification was used to evaluate cavernous sinus invasion by the adenomas. Receiver operating characteristic analyses were used to determine the diagnostic performance of T1 and T2 values. RESULTS: Quantitative T1 and T2 values yielded from MRF of gonadotroph pituitary macroadenomas were significantly higher than those of the non-gonadotroph pituitary macroadenomas (p < 0.001 and = 0.002, respectively). The AUC for the T2 value (0.888) was significantly greater than that for the T1 value (0.742) (p = 0.034). The AUC for combined T1 and T2 values was 0.885. Non-gonadotroph pituitary macroadenomas were more likely to invade the cavernous sinus than gonadotroph pituitary macroadenomas (55% vs 26%, p = 0.026). CONCLUSIONS: MRF may help to preoperatively differentiate between gonadotroph and non-gonadotroph pituitary macroadenomas and may be useful in guiding the treatment of these adenomas. KEY POINTS: • Somatostatin receptor type 3 is the most abundant receptor subtype in gonadotroph pituitary adenomas. • Magnetic resonance fingerprinting may help to preoperatively differentiate between gonadotroph and non-gonadotroph pituitary macroadenomas. • Magnetic resonance fingerprinting shows potential for guiding the treatment of pituitary macroadenomas.


Assuntos
Adenoma , Gonadotrofos , Neoplasias Hipofisárias , Adenoma/diagnóstico por imagem , Adenoma/cirurgia , Humanos , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Neoplasias Hipofisárias/diagnóstico por imagem , Neoplasias Hipofisárias/cirurgia
4.
Eur J Nucl Med Mol Imaging ; 47(6): 1435-1445, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31811342

RESUMO

OBJECTIVES: The introduction of the 2016 WHO classification of CNS tumors has made the combined molecular and histopathological characterization of tumors a pivotal part of glioma patient management. Recent publications on radiogenomics-based prediction of the mutational status have demonstrated the predictive potential of imaging-based, non-invasive tissue characterization algorithms. Hence, the aim of this study was to assess the potential of multiparametric 18F-FET PET-MRI including MR fingerprinting accelerated with machine learning and radiomic algorithms to predict tumor grading and mutational status of patients with cerebral gliomas. MATERIALS AND METHODS: 42 patients with suspected primary brain tumor without prior surgical or systemic treatment or biopsy underwent an 18F-FET PET-MRI examination. To differentiate the mutational status and the WHO grade of the cerebral tumors, support vector machine and random forest were trained with the radiomics signature of the multiparametric PET-MRI data including MR fingerprinting. Surgical sampling served as a gold standard for histopathological reference and assessment of mutational status. RESULTS: The 5-fold cross-validated area under the curve in predicting the ATRX mutation was 85.1%, MGMT mutation was 75.7%, IDH1 was 88.7%, and 1p19q was 97.8%. The area under the curve of differentiating low-grade glioma vs. high-grade glioma was 85.2%. CONCLUSION: 18F-FET PET-MRI and MR fingerprinting enable high-quality imaging-based tumor decoding and phenotyping for differentiation of low-grade vs. high-grade gliomas and for prediction of the mutational status of ATRX, IDH1, and 1p19q. These initial results underline the potential of 18F-FET PET-MRI to serve as an alternative to invasive tissue characterization.


Assuntos
Neoplasias Encefálicas , Glioma , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/genética , Glioma/diagnóstico por imagem , Glioma/genética , Humanos , Imageamento por Ressonância Magnética , Tomografia por Emissão de Pósitrons , Tirosina
5.
MAGMA ; 33(6): 783-791, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32248322

RESUMO

OBJECTIVE: To compare the absolute values and repeatability of magnetic resonance fingerprinting (MRF) with 3000 and 1500 echoes/slice acquired in 41 s and 20 s (MRF3k and MRF1.5k, respectively). MATERIALS AND METHODS: MRF3k and MRF1.5k scans based on fast imaging with steady precession (FISP) were conducted using a 3 T scanner. Inter-scan agreement and intra-scan repeatability were investigated in 41 and 28 subjects, respectively. Region-of-interest (ROI) analysis was conducted on T1 values of MRF3k by two raters, and their agreement was evaluated using intraclass correlation coefficients (ICCs). Between MRF3k and MRF1.5k, differences in T1 and T2 values and inter-measurement correlation coefficients (CCs) were investigated. Intra-measurement repeatability was evaluated using coefficients of variation (CVs). A p value < 0.05 was considered statistically significant. RESULTS: The ICCs of ROI measurements were 0.77-0.96. Differences were observed between the two MRF scans, but the CCs of the overall ROIs were 0.99 and 0.97 for the T1 and T2 values, respectively. The mean and median CVs of repeatability were equal to or less than 1.58% and 3.13% in each of the ROIs for T1 and T2, respectively; there were some significant differences between MRF3k and MRF1.5k, but they were small, measuring less than 1%. DISCUSSION: Both MRF3k and MRF1.5k had high repeatability, and a strong to very strong correlation was observed, with a trend toward slightly higher values in MRF1.5k.


Assuntos
Imageamento por Ressonância Magnética , Aceleração , Humanos , Espectroscopia de Ressonância Magnética , Imagens de Fantasmas , Reprodutibilidade dos Testes , Voluntários
6.
Radiology ; 292(2): 429-437, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31210615

RESUMO

Background Only sparse literature investigates the reproducibility and repeatability of relaxometry methods in MRI. However, statistical data on reproducibility and repeatability of any quantitative method is essential for clinical application. Purpose To evaluate the reproducibility and repeatability of two-dimensional fast imaging with steady-state free precession MR fingerprinting in vivo in human brains. Materials and Methods Two-dimensional section-selective MR fingerprinting based on a steady-state free precession sequence with an external radiofrequency transmit field, or B1+, correction was used to generate T1 and T2 maps. This prospective study was conducted between July 2017 and January 2018 with 10 scanners from a single manufacturer, including different models, at four different sites. T1 and T2 relaxation times and their variation across scanners (reproducibility) as well as across repetitions on a scanner (repeatability) were analyzed. The relative deviations of T1 and T2 to the average (95% confidence interval) were calculated for several brain compartments. Results Ten healthy volunteers (mean age ± standard deviation, 28.5 years ± 6.9; eight men, two women) participated in this study. Reproducibility and repeatability of T1 and T2 measures in the human brain varied across brain compartments (1.8%-20.9%) and were higher in solid tissues than in the cerebrospinal fluid. T1 measures in solid tissue brain compartments were more stable compared with T2 measures. The half-widths of the confidence intervals for relative deviations were 3.4% for mean T1 and 8.0% for mean T2 values across scanners. Intrascanner repeatability half-widths of the confidence intervals for relative deviations were in the range of 2.0%-3.1% for T1 and 3.1%-7.9% for T2. Conclusion This study provides values on reproducibility and repeatability of T1 and T2 relaxometry measured with fast imaging with steady-state free precession MR fingerprinting in brain tissues of healthy volunteers. Reproducibility and repeatability are considerably higher in solid brain compartments than in cerebrospinal fluid and are higher for T1 than for T2. © RSNA, 2019 Online supplemental material is available for this article. See also the editorial by Barkhof and Parker in this issue.


Assuntos
Encéfalo/anatomia & histologia , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Adulto , Encéfalo/fisiologia , Feminino , Humanos , Masculino , Estudos Prospectivos , Valores de Referência , Reprodutibilidade dos Testes
7.
Magn Reson Med ; 81(4): 2347-2359, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30320925

RESUMO

PURPOSE: To develop and evaluate the magnetic resonance field fingerprinting method that simultaneously generates T1 , T2 , B0 , and B 1 + maps from a single continuous measurement. METHODS: An encoding pattern was designed to integrate true fast imaging with steady-state precession (TrueFISP), fast imaging with steady-state precession (FISP), and fast low-angle shot (FLASH) sequence segments with varying flip angles, radio frequency (RF) phases, TEs, and gradient moments in a continuous acquisition. A multistep matching process was introduced that includes steps for integrated spiral deblurring and the correction of intravoxel phase dispersion. The method was evaluated in phantoms as well as in vivo studies in brain and lower abdomen. RESULTS: Simultaneous measurement of T1 , T2 , B0 , and B 1 + is achieved with T1 and T2 subsequently being less afflicted by B0 and B 1 + variations. Phantom results demonstrate the stability of generated parameter maps. Higher undersampling factors and spatial resolution can be achieved with the proposed method as compared with solely FISP-based magnetic resonance fingerprinting. High-resolution B0 maps can potentially be further used as diagnostic information. CONCLUSION: The proposed magnetic resonance field fingerprinting method can estimate T1 , T2 , B0 , and B 1 + maps accurately in phantoms, in the brain, and in the lower abdomen.


Assuntos
Encéfalo/diagnóstico por imagem , Campos Magnéticos , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Abdome/diagnóstico por imagem , Algoritmos , Análise de Fourier , Voluntários Saudáveis , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador/métodos , Reprodutibilidade dos Testes , Vibração
8.
Eur J Orthop Surg Traumatol ; 29(3): 659-666, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30310989

RESUMO

PURPOSE: To evaluate the usefulness of a novel MRI sequence strategy in the assessment of the periprosthetic anatomical structures after primary total knee arthroplasty. METHODS: Two MR sequences were retrospectively compared for the imaging of 15 patients with implanted cruciate-retaining/fixed-bearing TKAs (DePuy, PFC Sigma): a slice encoding sequence for metal artifact correction (SEMAC) and a standard sequence. Images were acquired on a 1.5-T system. The degree of artifact reduction was assessed using several qualitative (Likert-type scale) (artifact size, distorsion, blur, image quality, periprosthetic bone, posterior cruciate ligament, lateral collateral ligament, medial collateral ligament, patella tendon, popliteal vessels) and quantitative (artifact volume, Insall-Salvati index, length of patella/tendon, prosthesis dimensions) parameters by blinded reads performed by four investigators. The SEMAC sequences were statistically compared with the standard sequence using Wilcoxon test. Additionally, the intraclass correlation coefficient (ICC) for interobserver agreement was calculated. RESULTS: Higher levels of blurring were found with SEMAC compared to standard sequences (p < 0.001). All other qualitative parameters improved significantly with the application of SEMAC. In comparison with conventional sequences, the artifact volume was reduced by 59% utilizing SEMAC. Thus, the artifact reduction improved the precision of measurements such as Insall-Salvati index and length of patella/tendon (p < 0.001). The dimension of the tibial component (Ti alloy/polyethylene) revealed accurate values with both MRI sequences. A sufficient interobserver agreement among all readers was found with SEMAC, qualitatively ICC 0.9 (range 0.8-1) as well as quantitatively ICC 0.95 (range 0.92-0.98). CONCLUSIONS: SEMAC effectively reduces artifacts caused by metallic implants after total knee arthroplasty relative to standard imaging. This allows for an improved assessment of periprosthetic anatomical structures. This might enable an improved detectability of postoperative complications in the future. LEVEL OF EVIDENCE: Diagnostic Study Level III.


Assuntos
Artroplastia do Joelho/efeitos adversos , Artefatos , Articulação do Joelho/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Prótese do Joelho , Masculino , Metais , Pessoa de Meia-Idade , Estudos Retrospectivos
9.
J Magn Reson Imaging ; 47(5): 1306-1315, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-28940951

RESUMO

BACKGROUND: Interventional magnetic resonance imaging (MRI) at 3T benefits from higher spatial and temporal resolution, but artifacts of metallic instruments are often larger and may obscure target structures. PURPOSE: To test that compressed sensing (CS) slice-encoding metal artifact correction (SEMAC) is feasible for 3T interventional MRI and affords more accurate instrument visualization than turbo spin echo (TSE) and gradient echo (GRE) techniques, and facilitates faster data acquisition than conventional SEMAC. STUDY TYPE: Prospective. PHANTOM AND SUBJECTS: Cadaveric animal and 20 human subjects. FIELD STRENGTH/SEQUENCE: TSE (acquisition time 31 sec), GRE (28-33 sec), SEMAC (128 sec), and CS-SEMAC (57 sec) pulse sequences were evaluated at 3T. ASSESSMENT: Artifact width and length, signal-to-noise (SNR), and contrast-to-noise (CNR) ratios of 14-22G MR-conditional needles were measured in a phantom. Subsequently, high-bandwidth TSE and CS-SEMAC sequences were assessed in vivo with 20 patient procedures for the size of the metal artifact, image sharpness, image noise, motion artifacts, image contrast, and target, instrument, and structural visibility. STATISTICAL TESTS: Repeated-measures-analysis-of-variances and Mann-Whitney U-tests were applied. P ≤ 0.05 was considered statistically significant. RESULTS: CS-SEMAC and SEMAC created the smallest needle artifact widths (3.2-3.3 ± 0.4 mm, P = 1.0), whereas GRE showed the largest needle artifact widths (8.5-8.6 ± 0.4 mm) (P < 0.001). The artifact width difference between high-bandwidth TSE and CS-SEMAC was 0.8 ± 0.6 mm (P < 0.01). SEMAC and CS-SEMAC created the lowest average needle tip errors (0.3-0.4 ± 0.1 mm, P = 1.0). The average tip error difference between high-bandwidth TSE and SEMAC/CS-SEMAC was 2.0 ± 1.7 mm (P < 0.01). SNR and CNR were similar on TSE, SEMAC, and CS-SEMAC, and lowest on GRE. CS-SEMAC yielded smaller artifacts, less noise, less motion, and better instrument visibility (P < 0.001); high-bandwidth TSE showed better sharpness (P < 0.001) and targets visibility (P = 0.007); whereas image contrast (P = 0.273) and structural visibility (P = 0.1) were similar. DATA CONCLUSION: CS-SEMAC is feasible for interventional MRI at 3T, visualizes instruments with higher accuracy than high-bandwidth TSE and GRE, and can be acquired 55% faster than conventional SEMAC. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 6 J. Magn. Reson. Imaging 2018;47:1306-1315.


Assuntos
Artefatos , Meios de Contraste/química , Imagem por Ressonância Magnética Intervencionista , Adulto , Idoso , Animais , Biópsia por Agulha , Cadáver , Estudos de Viabilidade , Feminino , Análise de Fourier , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Estudos Prospectivos , Reprodutibilidade dos Testes , Razão Sinal-Ruído , Fatores de Tempo , Adulto Jovem
10.
Eur Radiol ; 28(5): 2216-2227, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29218618

RESUMO

OBJECTIVES: To assess high-bandwidth and compressed sensing-(CS)-SEMAC turbo spin echo (TSE) techniques for metal artifact reduction MRI of total ankle arthroplasty (TAA) implants. METHODS: Following institutional approval and consent, 40 subjects with TAA implants underwent 1.5-T MRI prospectively. Evaluations included bone-implant interfaces, anatomical structures, abnormal findings and differential diagnoses before and after MRI. AUCs of P-P plots were used to determine superiority. Statistical differences were evaluated with McNemar and chi-square tests. P-values ≤ 0.05 were considered significant. RESULTS: CS-SEMAC TSE was superior to high-bandwidth TSE in showing the bone-implant interfaces (AUC=0.917), periprosthetic bone, tendons and joint capsule (AUC=0.337-0.766), bone marrow oedema (43 % difference, p=0.041), interface osteolysis (63 %, p=0.015), tendinopathy (62 %, p=0.062), periprosthetic fractures (60 %, p=0.250), synovitis (43 %, p=0.250), as well as reader confidence for bone marrow oedema (p=<0.001), fracture (p=0.001), interface osteolysis (p=0.003), synovitis (p=0.027) and tendinopathy (p=0.034). The number of differential diagnoses in symptomatic subjects after the MRI with CS-SEMAC decreased from 3 (1-4) to 1 (1-2) (p<0.001). CONCLUSIONS: MRI of TAA implants with CS-SEMAC improves the diagnosis of interface osteolysis, periprosthetic bone marrow oedema, fractures and tendinopathy when compared to high-BW TSE, and has a positive effect on patient management. KEY POINTS: • High-bandwidth TSE and compressed sensing SEMAC improve MRI of ankle arthroplasty implants. • Compressed sensing SEMAC improves bone-implant interfaces, periprosthetic bone, tendons and joint capsule visibility. • Compressed sensing SEMAC improves the diagnosis of osteolysis, tendinopathy, fractures and synovitis. • MRI decreases the number of clinical differential diagnoses of painful ankle arthroplasty implants.


Assuntos
Articulação do Tornozelo/diagnóstico por imagem , Artroplastia de Substituição do Tornozelo , Artefatos , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Próteses e Implantes , Idoso , Articulação do Tornozelo/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
11.
Magn Reson Med ; 78(1): 79-87, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-27454003

RESUMO

PURPOSE: To develop an accelerated SEMAC metal implant MRI technique (Sparse-SEMAC) with reduced scan time and improved metal distortion correction. METHODS: Sparse-SEMAC jointly exploits the inherent sparsity along the additional phase-encoding dimension and multicoil encoding capabilities to significantly accelerate data acquisition. A prototype pulse sequence with pseudorandom ky -kz undersampling and an inline image reconstruction was developed for integration in clinical studies. Three patients with hip implants were imaged using the proposed Sparse-SEMAC with eight-fold acceleration and compared with the standard-SEMAC technique used in clinical studies (three-fold GRAPPA acceleration). Measurements were performed with SEMAC-encoding steps (SES) = 15 for Sparse-SEMAC and SES = 9 for Standard-SEMAC using high spatial resolution Proton Density (PD) and lower-resolution STIR acquisitions. Two expert musculoskeletal (MSK) radiologists performed a consensus reading to score image-quality parameters. RESULTS: Sparse-SEMAC enables up to eight-fold acceleration of data acquisition that results in two-fold scan time reductions, compared with Standard-SEMAC, with improved metal artifact correction for patients with hip implants without degrading spatial resolution. CONCLUSION: The high acceleration enabled by Sparse-SEMAC would enable clinically feasible examination times with improved correction of metal distortion. Magn Reson Med 78:79-87, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Assuntos
Algoritmos , Artefatos , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Metais , Próteses e Implantes , Processamento de Sinais Assistido por Computador , Cadáver , Compressão de Dados/métodos , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
12.
Eur Radiol ; 27(12): 5104-5112, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28698944

RESUMO

OBJECTIVES: Dental MRI is often impaired by artefacts due to metallic dental materials. Several sequences were developed to reduce susceptibility artefacts. Here, we evaluated a set of sequences for artefact reduction for dental MRI for the first time. METHODS: Artefact volume, signal-to-noise ratio (SNR) and image quality were assessed on a 3-T MRI for pointwise encoding time reduction with radial acquisition (PETRA), multiple-slab acquisition with view angle tilting gradient, based on a sampling perfection with application-optimised contrasts using different flip angle evolution (SPACE) sequence (MSVAT-SPACE), slice-encoding for metal-artefact correction (SEMAC) and compared to a standard SPACE and a standard turbo-spin-echo (TSE) sequence. Field-of-view and acquisition times were chosen to enable in vivo application. Two implant-supported prostheses were tested (porcelain fused to metal non-precious alloy and monolithic zirconia). RESULTS: Smallest artefact was measured for TSE sequences with no difference between the standard TSE and the SEMAC. MSVAT-SPACE reduced artefacts about 56% compared to the standard SPACE. Effect of the PETRA was dependent on sample used. Image quality and SNR were comparable for all sequences except PETRA, which yielded poor results. CONCLUSION: There is no benefit in terms of artefact reduction for SEMAC compared to standard TSE. Usage of MSVAT-SPACE is advantageous since artefacts are reduced and higher resolution is achieved. KEY POINTS: • SEMAC is not superior to TSE in terms of artefact reduction. • MSVAT-SPACE reduces susceptibility artefacts while maintaining comparable image quality. • PETRA reduces susceptibility artefacts depending on material but offers poor image quality.


Assuntos
Artefatos , Materiais Dentários , Prótese Dentária Fixada por Implante , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Metais , Meios de Contraste , Humanos , Razão Sinal-Ruído , Zircônio
13.
Semin Musculoskelet Radiol ; 21(5): 604-615, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-29025189

RESUMO

The vast majority of the metal-related artifacts in magnetic resonance imaging (MRI) arise from B0 inhomogeneity. These artifacts include failed fat suppression, signal loss, signal pileup, and image distortions. Metal artifact reduction sequence MRI has been used to mitigate these artifacts via optimization of the scan parameters and exploiting new techniques such as fully phase-encoded imaging and multispectral imaging including multi-acquisition variable-resonance image combination and slice encoding for metal artifact correction. Applicability of MRI in the vicinity of metal implants has been revolutionized by these new techniques at the expense of longer acquisition times. To reach clinically viable scan times, these novel techniques have been successfully coupled with various acceleration paradigms such as parallel imaging and compressed sensing.


Assuntos
Artroplastia de Quadril , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Complicações Pós-Operatórias/diagnóstico por imagem , Artefatos , Humanos , Falha de Prótese
14.
Magn Reson Med ; 75(1): 217-26, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25684374

RESUMO

PURPOSE: To investigate the benefit of a two-channel transmit system on shading close to total hip replacements and other elongated metal structures in parallel to the magnet bore. METHODS: An analytical model comprising a water cylinder and a metal rod is introduced to describe the B1 effects close to elongated metal structures and it is verified. The dependence of the optimal polarization, which induces minimum shading, on the position of the metal is analyzed. Furthermore, the optimal polarization for two patients is determined both on the basis of the model and experimentally and its benefit compared with circular polarization is investigated. RESULTS: The cylindrical model approximates the modification of the B1 field due to the metal well, and the optimal polarization strongly depends on the position of the rod. In vivo, shading can be ameliorated by the use of the optimal polarization; for total hip replacements with shafts of titanium, this polarization can be determined on the basis of both the analytical model and the experimental data. CONCLUSION: Parallel transmission offers the possibility of a substantial reduction of shading close to long metal structures in parallel to the magnet bore.


Assuntos
Artefatos , Articulação do Quadril/patologia , Prótese de Quadril , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Algoritmos , Humanos , Imageamento por Ressonância Magnética/instrumentação , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
15.
Skeletal Radiol ; 45(10): 1345-56, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27497594

RESUMO

OBJECTIVE: Compressed sensing (CS) acceleration has been theorized for slice encoding for metal artifact correction (SEMAC), but has not been shown to be feasible. Therefore, we tested the hypothesis that CS-SEMAC is feasible for MRI of metal-on-metal hip resurfacing implants. MATERIALS AND METHODS: Following prospective institutional review board approval, 22 subjects with metal-on-metal hip resurfacing implants underwent 1.5 T MRI. We compared CS-SEMAC prototype, high-bandwidth TSE, and SEMAC sequences with acquisition times of 4-5, 4-5 and 10-12 min, respectively. Outcome measures included bone-implant interfaces, image quality, periprosthetic structures, artifact size, and signal- and contrast-to-noise ratios (SNR and CNR). Using Friedman, repeated measures analysis of variances, and Cohen's weighted kappa tests, Bonferroni-corrected p-values of 0.005 and less were considered statistically significant. RESULTS: There was no statistical difference of outcomes measures of SEMAC and CS-SEMAC images. Visibility of implant-bone interfaces and pseudocapsule as well as fat suppression and metal reduction were "adequate" to "good" on CS-SEMAC and "non-diagnostic" to "adequate" on high-BW TSE (p < 0.001, respectively). SEMAC and CS-SEMAC showed mild blur and ripple artifacts. The metal artifact size was 63 % larger for high-BW TSE as compared to SEMAC and CS-SEMAC (p < 0.0001, respectively). CNRs were sufficiently high and statistically similar, with the exception of CNR of fluid and muscle and CNR of fluid and tendon, which were higher on intermediate-weighted high-BW TSE (p < 0.005, respectively). CONCLUSION: Compressed sensing acceleration enables the time-neutral use of SEMAC for MRI of metal-on-metal hip resurfacing implants when compared to high-BW TSE and image quality similar to conventional SEMAC.


Assuntos
Artefatos , Compressão de Dados/métodos , Articulação do Quadril/diagnóstico por imagem , Prótese de Quadril , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Próteses Articulares Metal-Metal , Adulto , Idoso , Algoritmos , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Razão Sinal-Ruído
16.
J Magn Reson Imaging ; 41(6): 1570-80, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25155582

RESUMO

BACKGROUND: To investigate the impact of high-bandwidth radiofrequency (RF) pulses used in turbo spin echo (TSE) sequences or combined with slice encoding for metal artifact correction (SEMAC) on artifact reduction at 3 Tesla in the knee in the presence of metal. METHODS: Local transmit/receive coils feature increased maximum B1 amplitude, reduced SAR exposition and thus enable the application of high-bandwidth RF pulses. Susceptibility-induced through-plane distortion scales inversely with the RF bandwidth and the view angle, hence blurring, increases for higher RF bandwidths, when SEMAC is used. These effects were assessed for a phantom containing a total knee arthroplasty. TSE and SEMAC sequences with conventional and high RF bandwidths and different contrasts were tested on eight patients with different types of implants. To realize scan times of 7 to 9 min, SEMAC was always applied with eight slice-encoding steps and distortion was rated by two radiologists. RESULTS: A local transmit/receive knee coil enables the use of an RF bandwidth of 4 kHz compared with 850 Hz in conventional sequences. Phantom scans confirm the relation of RF bandwidth and through-plane distortion, which can be reduced up to 79%, and demonstrate the increased blurring for high-bandwidth RF pulses. In average, artifacts in this RF mode are rated hardly visible for patients with joint arthroplasties, when eight SEMAC slice-encoding steps are applied, and for patients with titanium fixtures, when TSE is used. CONCLUSION: The application of high-bandwidth RF pulses by local transmit coils substantially reduces through-plane distortion artifacts at 3 Tesla.


Assuntos
Artroplastia do Joelho , Aumento da Imagem/métodos , Prótese do Joelho , Imageamento por Ressonância Magnética/instrumentação , Artefatos , Humanos , Metais , Imagens de Fantasmas
17.
Skeletal Radiol ; 43(8): 1101-12, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24838109

RESUMO

OBJECTIVE: To apply and compare magnetic resonance imaging (MRI) metal artifact reducing sequences (MARS) including subtraction imaging after contrast application in patients with metal-on-metal (MoM) hip prostheses, investigate the prevalence and characteristics of periprosthetic abnormalities, as well as their relation with pain and risk factors. MATERIALS AND METHODS: Fifty-two MoM prostheses (35 cases with pain and or risk factors, and 17 controls) in 47 patients were examined in a 1.5-T MR scanner using MARS: turbo spin echo (TSE) with high readout bandwidth with and without view angle tilting (VAT), TSE with VAT and slice encoding for metal artifact correction (SEMAC), short tau inversion recovery (STIR) with matched RF pulses, and post-contrast imaging. The relations of MRI findings to pain and risk factors were analyzed and in five revised hips findings from operation, histology, and MRI were compared. RESULTS: TSE VAT detected the highest number of osteolyses. Soft tissue mass, effusion, and capsular thickening were common, whereas osteolysis in acetabulum and femur were less frequent. Contrast enhancement occurred in bone, synovia, joint capsule, and the periphery of soft tissue mass. There was no significant relation between MRI findings and pain or risk factors. CONCLUSIONS: MARS and gadolinium subtraction imaging are useful for evaluation of complications to MoM prosthesis. TSE VAT had the highest sensitivity for osteolysis. Contrast enhancement might indicate activation of aseptic lymphocyte-dominated vasculitis-associated lesion (ALVAL). Pain, small head, or steep prosthesis inclination angle are not useful predictors of periprosthetic abnormalities, and wide indications for MR follow-up are warranted.


Assuntos
Artefatos , Meios de Contraste , Gadolínio , Prótese de Quadril/efeitos adversos , Imageamento por Ressonância Magnética/métodos , Osteólise/diagnóstico , Adulto , Idoso , Artroplastia de Quadril/efeitos adversos , Estudos de Casos e Controles , Desenho de Equipamento , Feminino , Articulação do Quadril/patologia , Humanos , Aumento da Imagem/métodos , Masculino , Metais , Pessoa de Meia-Idade , Variações Dependentes do Observador , Osteólise/etiologia , Dor/etiologia , Fatores de Risco , Sensibilidade e Especificidade , Técnica de Subtração
18.
Invest Radiol ; 59(5): 359-371, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-37812483

RESUMO

OBJECTIVE: Given the limited repeatability and reproducibility of radiomic features derived from weighted magnetic resonance imaging (MRI), there may be significant advantages to using radiomics in conjunction with quantitative MRI. This study introduces a novel physics-informed discretization (PID) method for reproducible radiomic feature extraction and evaluates its performance using quantitative MRI sequences including magnetic resonance fingerprinting (MRF) and apparent diffusion coefficient (ADC) mapping. MATERIALS AND METHODS: A multiscanner, scan-rescan dataset comprising whole-brain 3D quantitative (MRF T1, MRF T2, and ADC) and weighted MRI (T1w MPRAGE, T2w SPACE, and T2w FLAIR) from 5 healthy subjects was prospectively acquired. Subjects underwent 2 repeated acquisitions on 3 distinct 3 T scanners each, for a total of 6 scans per subject (30 total scans). First-order statistical (n = 23) and second-order texture (n = 74) radiomic features were extracted from 56 brain tissue regions of interest using the proposed PID method (for quantitative MRI) and conventional fixed bin number (FBN) discretization (for quantitative MRI and weighted MRI). Interscanner radiomic feature reproducibility was measured using the intraclass correlation coefficient (ICC), and the effect of image sequence (eg, MRF T1 vs T1w MPRAGE), as well as image discretization method (ie, PID vs FBN), on radiomic feature reproducibility was assessed using repeated measures analysis of variance. The robustness of PID and FBN discretization to segmentation error was evaluated by simulating segmentation differences in brainstem regions of interest. Radiomic features with ICCs greater than 0.75 following simulated segmentation were determined to be robust to segmentation. RESULTS: First-order features demonstrated higher reproducibility in quantitative MRI than weighted MRI sequences, with 30% (n = 7/23) features being more reproducible in MRF T1 and MRF T2 than weighted MRI. Gray level co-occurrence matrix (GLCM) texture features extracted from MRF T1 and MRF T2 were significantly more reproducible using PID compared with FBN discretization; for all quantitative MRI sequences, PID yielded the highest number of texture features with excellent reproducibility (ICC > 0.9). Comparing texture reproducibility of quantitative and weighted MRI, a greater proportion of MRF T1 (n = 225/370, 61%) and MRF T2 (n = 150/370, 41%) texture features had excellent reproducibility (ICC > 0.9) compared with T1w MPRAGE (n = 148/370, 40%), ADC (n = 115/370, 32%), T2w SPACE (n = 98/370, 27%), and FLAIR (n = 102/370, 28%). Physics-informed discretization was also more robust than FBN discretization to segmentation error, as 46% (n = 103/222, 46%) of texture features extracted from quantitative MRI using PID were robust to simulated 6 mm segmentation shift compared with 19% (n = 42/222, 19%) of weighted MRI texture features extracted using FBN discretization. CONCLUSIONS: The proposed PID method yields radiomic features extracted from quantitative MRI sequences that are more reproducible and robust than radiomic features extracted from weighted MRI using conventional (FBN) discretization approaches. Quantitative MRI sequences also demonstrated greater scan-rescan robustness and first-order feature reproducibility than weighted MRI.


Assuntos
Imageamento por Ressonância Magnética , Radiômica , Humanos , Reprodutibilidade dos Testes , Imageamento por Ressonância Magnética/métodos , Imagem de Difusão por Ressonância Magnética , Encéfalo/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos
19.
AJR Am J Roentgenol ; 201(6): 1315-24, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24261373

RESUMO

OBJECTIVE: The purpose of this article is to compare slice-encoding for metal artifact correction (SEMAC) sequences versus optimized standard MRI sequences in patients with total knee arthroplasty (TKA). SUBJECTS AND METHODS: Forty-two patients with TKA underwent 1.5-T MRI. Sequences optimized for metal implant imaging (SEMAC) were compared with standard sequences optimized with high bandwidth for STIR and proton density (PD)-weighted images. In 29 patients, CT was available as reference standard. Signal void and insufficient fat saturation were quantified. Qualitative criteria (anatomy, distortion, blurring, and noise) were assessed on a 5-point scale (1, no artifacts; 5, severe artifacts) by two readers. Abnormal imaging findings were noted. A Student t test and a Wilcoxon signed rank test was used for statistics. RESULTS: Signal void areas and insufficient fat saturation were smaller for the SEMAC sequences than for the optimized standard sequences (p ≤ 0.005 for all comparisons). Depiction of anatomic structures was better on STIR with SEMAC versus standard sequences optimized with high bandwidth (score range, 2.9-3.7 vs 4.2-4.9) and on PD-weighted imaging with SEMAC versus standard sequences optimized with high bandwidth (score range, 2.5-3.5 vs 3.1-3.8), which was statistically significant (p < 0.001 to p = 0.007 for different structures). Distortion and noise were lower for SEMAC than for the standard sequences (p ≤ 0.001), whereas no technique had a clear advantage for blurring. Detection of abnormal imaging findings was markedly increased for the SEMAC technique (p < 0.001) and was most pronounced for STIR images (98 and 74 findings for STIR with SEMAC for readers 1 and 2, respectively, vs 37 and 37 findings for readers 1 and 2, respectively, for STIR with standard sequences optimized with high bandwidth). Sensitivity for detection of periprosthetic osteolysis was improved for STIR with SEMAC (100% and 86% for readers 1 and 2, respectively) compared with STIR with standard sequences optimized with high bandwidth (14% and 29% for readers 1 and 2, respectively). CONCLUSION: SEMAC sequences showed a statistically significant artifact reduction. The detection of clinically relevant findings such as periprosthetic osteolysis was markedly improved.


Assuntos
Artroplastia do Joelho , Artefatos , Aumento da Imagem/métodos , Prótese do Joelho , Imageamento por Ressonância Magnética/métodos , Metais , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Osteólise/diagnóstico , Sensibilidade e Especificidade
20.
J Dent ; 130: 104422, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36649822

RESUMO

OBJECTIVES: To determine the reliability and accuracy of intraoral radiography (IR), cone-beam-computed tomography (CBCT), and dental magnetic resonance imaging (dMRI) in measuring peri­implant bone defects around single zirconia implants. METHODS: Twenty-four zirconia implants were inserted in bovine ribs with various peri­implant defect sizes and morphologies. True defect extent was measured without implant in CBCT. Defects were measured twice in IR, CBCT, and dMRI with the inserted implant by three experienced readers. Reliability was assessed by ICC, accuracy by the Friedman test, and post-hoc-Tukey's test. RESULTS: A comparable good to excellent intra- and inter-reader reliability was observed for all modalities (intra-/inter-rater-CC range for IR; CBCT; dMRI: 0.81-0.91/0.79;0.87-0.97/0.96;0.87-0.95/0.94). Accuracy was generally high, with mean errors below 1 mm in all directions. However, measuring defect depth in the mesiodistal direction was significantly more accurate in dMRI (0.65 ± 0.38 mm) compared to IR (2.71 ± 1.91 mm), and CBCT (1.98 ± 1.97 mm), p-values ≤ 0.0001 respectively ≤ 0.01. CONCLUSIONS: Osseous defects around zirconia implants can be reliably measured in IR/CBCT/dMRI in the mesiodistal directions. In addition, CBCT and dMRI allow assessment of the buccolingual directions. dMRI provides a comparable accuracy in all directions, except for the mesiodistal defect depth, where it outperforms IR and CBCT.


Assuntos
Implantes Dentários , Animais , Bovinos , Reprodutibilidade dos Testes , Estudos de Viabilidade , Tomografia Computadorizada de Feixe Cônico/métodos , Imageamento por Ressonância Magnética , Radiografia Dentária
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA