Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Neuroimage ; 276: 120178, 2023 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-37236554

RESUMO

Instantaneous and peak frequency changes in neural oscillations have been linked to many perceptual, motor, and cognitive processes. Yet, the majority of such studies have been performed in sensor space and only occasionally in source space. Furthermore, both terms have been used interchangeably in the literature, although they do not reflect the same aspect of neural oscillations. In this paper, we discuss the relation between instantaneous frequency, peak frequency, and local frequency, the latter also known as spectral centroid. Furthermore, we propose and validate three different methods to extract source signals from multichannel data whose (instantaneous, local, or peak) frequency estimate is maximally correlated to an experimental variable of interest. Results show that the local frequency might be a better estimate of frequency variability than instantaneous frequency under conditions with low signal-to-noise ratio. Additionally, the source separation methods based on local and peak frequency estimates, called LFD and PFD respectively, provide more stable estimates than the decomposition based on instantaneous frequency. In particular, LFD and PFD are able to recover the sources of interest in simulations performed with a realistic head model, providing higher correlations with an experimental variable than multiple linear regression. Finally, we also tested all decomposition methods on real EEG data from a steady-state visual evoked potential paradigm and show that the recovered sources are located in areas similar to those previously reported in other studies, thus providing further validation of the proposed methods.


Assuntos
Eletroencefalografia , Magnetoencefalografia , Humanos , Eletroencefalografia/métodos , Magnetoencefalografia/métodos , Potenciais Evocados Visuais , Razão Sinal-Ruído , Algoritmos
2.
Neuroimage ; 201: 116009, 2019 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-31302256

RESUMO

Synchronization between oscillatory signals is considered to be one of the main mechanisms through which neuronal populations interact with each other. It is conventionally studied with mass-bivariate measures utilizing either sensor-to-sensor or voxel-to-voxel signals. However, none of these approaches aims at maximizing synchronization, especially when two multichannel datasets are present. Examples include cortico-muscular coherence (CMC), cortico-subcortical interactions or hyperscanning (where electroencephalographic EEG/magnetoencephalographic MEG activity is recorded simultaneously from two or more subjects). For all of these cases, a method which could find two spatial projections maximizing the strength of synchronization would be desirable. Here we present such method for the maximization of coherence between two sets of EEG/MEG/EMG (electromyographic)/LFP (local field potential) recordings. We refer to it as canonical Coherence (caCOH). caCOH maximizes the absolute value of the coherence between the two multivariate spaces in the frequency domain. This allows very fast optimization for many frequency bins. Apart from presenting details of the caCOH algorithm, we test its efficacy with simulations using realistic head modelling and focus on the application of caCOH to the detection of cortico-muscular coherence. For this, we used diverse multichannel EEG and EMG recordings and demonstrate the ability of caCOH to extract complex patterns of CMC distributed across spatial and frequency domains. Finally, we indicate other scenarios where caCOH can be used for the extraction of neuronal interactions.


Assuntos
Algoritmos , Encéfalo/fisiologia , Modelos Neurológicos , Músculo Esquelético/fisiologia , Neurônios/fisiologia , Animais , Conjuntos de Dados como Assunto , Eletroencefalografia , Eletromiografia , Humanos , Magnetoencefalografia , Análise Multivariada
3.
Neuroimage ; 140: 163-73, 2016 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-27125841

RESUMO

To explore the relationship between transcranial current stimulation (tCS) and the electroencephalography (EEG) forward problem, we investigate and compare accuracy and efficiency of a reciprocal and a direct EEG forward approach for dipolar primary current sources both based on the finite element method (FEM), namely the adjoint approach (AA) and the partial integration approach in conjunction with a transfer matrix concept (PI). By analyzing numerical results, comparing to analytically derived EEG forward potentials and estimating computational complexity in spherical shell models, AA turns out to be essentially identical to PI. It is then proven that AA and PI are also algebraically identical even for general head models. This relation offers a direct link between the EEG forward problem and tCS. We then demonstrate how the quasi-analytical EEG forward solutions in sphere models can be used to validate the numerical accuracies of FEM-based tCS simulation approaches. These approaches differ with respect to the ease with which they can be employed for realistic head modeling based on MRI-derived segmentations. We show that while the accuracy of the most easy to realize approach based on regular hexahedral elements is already quite high, it can be significantly improved if a geometry-adaptation of the elements is employed in conjunction with an isoparametric FEM approach. While the latter approach does not involve any additional difficulties for the user, it reaches the high accuracies of surface-segmentation based tetrahedral FEM, which is considerably more difficult to implement and topologically less flexible in practice. Finally, in a highly realistic head volume conductor model and when compared to the regular alternative, the geometry-adapted hexahedral FEM is shown to result in significant changes in tCS current flow orientation and magnitude up to 45° and a factor of 1.66, respectively.


Assuntos
Mapeamento Encefálico/métodos , Encéfalo/fisiologia , Eletroencefalografia/métodos , Potenciais Evocados/fisiologia , Modelos Neurológicos , Rede Nervosa/fisiologia , Estimulação Transcraniana por Corrente Contínua/métodos , Simulação por Computador , Condutividade Elétrica , Eletroencefalografia/normas , Cabeça/fisiologia , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
Neuroimage ; 91: 146-61, 2014 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-24418509

RESUMO

We present a novel approach to the third order spectral analysis, commonly called bispectral analysis, of electroencephalographic (EEG) and magnetoencephalographic (MEG) data for studying cross-frequency functional brain connectivity. The main obstacle in estimating functional connectivity from EEG and MEG measurements lies in the signals being a largely unknown mixture of the activities of the underlying brain sources. This often constitutes a severe confounder and heavily affects the detection of brain source interactions. To overcome this problem, we previously developed metrics based on the properties of the imaginary part of coherency. Here, we generalize these properties from the linear to the nonlinear case. Specifically, we propose a metric based on an antisymmetric combination of cross-bispectra, which we demonstrate to be robust to mixing artifacts. Moreover, our metric provides complex-valued quantities that give the opportunity to study phase relationships between brain sources. The effectiveness of the method is first demonstrated on simulated EEG data. The proposed approach shows a reduced sensitivity to mixing artifacts when compared with a traditional bispectral metric. It also exhibits a better performance in extracting phase relationships between sources than the imaginary part of the cross-spectrum for delayed interactions. The method is then applied to real EEG data recorded during resting state. A cross-frequency interaction is observed between brain sources at 10Hz and 20Hz, i.e., for alpha and beta rhythms. This interaction is then projected from signal to source level by using a fit-based procedure. This approach highlights a 10-20Hz dominant interaction localized in an occipito-parieto-central network.


Assuntos
Artefatos , Mapeamento Encefálico/métodos , Eletroencefalografia/métodos , Magnetoencefalografia/métodos , Adulto , Ritmo alfa/fisiologia , Ritmo beta/fisiologia , Feminino , Humanos , Masculino , Rede Nervosa/fisiologia , Lobo Occipital/fisiologia , Lobo Parietal/fisiologia , Valores de Referência , Adulto Jovem
5.
Neuroimage ; 79: 172-83, 2013 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-23631996

RESUMO

Resting state networks (RSNs) are sets of brain regions exhibiting temporally coherent activity fluctuations in the absence of imposed task structure. RSNs have been extensively studied with fMRI in the infra-slow frequency range (nominally <10(-1)Hz). The topography of fMRI RSNs reflects stationary temporal correlation over minutes. However, neuronal communication occurs on a much faster time scale, at frequencies nominally in the range of 10(0)-10(2)Hz. We examined phase-shifted interactions in the delta (2-3.5 Hz), theta (4-7 Hz), alpha (8-12 Hz) and beta (13-30 Hz) frequency bands of resting-state source space MEG signals. These analyses were conducted between nodes of the dorsal attention network (DAN), one of the most robust RSNs, and between the DAN and other networks. Phase shifted interactions were mapped by the multivariate interaction measure (MIM), a measure of true interaction constructed from the maximization of imaginary coherency in the virtual channels comprised of voxel signals in source space. Non-zero-phase interactions occurred between homologous left and right hemisphere regions of the DAN in the delta and alpha frequency bands. Even stronger non-zero-phase interactions were detected between networks. Visual regions bilaterally showed phase-shifted interactions in the alpha band with regions of the DAN. Bilateral somatomotor regions interacted with DAN nodes in the beta band. These results demonstrate the existence of consistent, frequency specific phase-shifted interactions on a millisecond time scale between cortical regions within RSN as well as across RSNs.


Assuntos
Mapeamento Encefálico/métodos , Encéfalo/fisiologia , Magnetoencefalografia/métodos , Modelos Neurológicos , Modelos Estatísticos , Análise Multivariada , Rede Nervosa/fisiologia , Descanso/fisiologia , Adulto , Simulação por Computador , Feminino , Humanos , Masculino
6.
Med Biol Eng Comput ; 44(6): 489-99, 2006 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-16937200

RESUMO

In the routine recording of magnetocardiograms (MCGs), it is necessary to underline the problem of noise cancellation. Source separation has often been suggested to solve this problem. In this paper, blind source separation (BSS), by means of singular value decomposition (SVD) and independent component analysis (ICA), was used for noise reduction in MCG data to improve the signal to noise ratio. Special techniques, based on statistical parameters, for identifying noise and disturbances, have been introduced to automatically eliminate noise-related and disturbance-related components before reconstructing cleaned data sets. The results show that ICA and SVD can detect and remove a variety of noise and artefact sources from MCG data, as well as from stress MCG.


Assuntos
Magnetocardiografia/métodos , Processamento de Sinais Assistido por Computador , Algoritmos , Artefatos , Humanos , Ruído , Análise de Componente Principal , Sensibilidade e Especificidade
7.
J Med Eng Technol ; 30(3): 158-65, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16772219

RESUMO

In 1992, Brockmeier et al. showed that there is a strong difference in magnetocardiography (MCG)-detected field distribution generated by the heart at rest and under stress. To study the possible clinical applications of this finding, it is convenient to avoid pharmacological stress and to perform stress MCG (SMCG) using conventional physical stress with an ergometer. When using a non-magnetic ergometer, the MCG recordings under physical stress are more noisy due to the unavoidable movement artefacts from the patient and from the residual artefacts of the ergometer. To remove these artefacts a denoising was performed using independent component analysis (ICA) in a new implementation. This work shows that with ICA in this special implementation it is becoming feasible to extract heart signals from SMCG data recorded during ergometer exercise.


Assuntos
Ergometria/estatística & dados numéricos , Teste de Esforço/estatística & dados numéricos , Coração/fisiologia , Interpretação Estatística de Dados , Humanos , Magnetismo
8.
Neuroreport ; 10(8): 1625-9, 1999 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-10501547

RESUMO

Human scalp-derived somatosensory evoked potentials contain a high-frequency wavelet burst, presumably reflecting repetitive synchronized population spikes. Here, the burst refractory behavior was characterized using median nerve electrostimulation with 18 frequencies (0.5-25Hz) for comparison with cellular burst characteristics. Above 10 Hz only a brief high-frequency (700 Hz) burst component remained discernible, which gradually decreased; possible generators comprise cells capable of generating spike bursts of extraordinarily high frequency, such as pyramidal 'chattering cells', cortical fast spiking inhibitory interneurons and some thalamocortical relay cells. At stimulation frequencies <4 Hz an additional late burst component appeared with only 494 Hz intraburst frequency. Comparably long refractory periods and low intraburst frequencies have been described for bursting cells driven by low-threshold calcium currents.


Assuntos
Potenciais Somatossensoriais Evocados/fisiologia , Potenciais de Ação/fisiologia , Adulto , Estimulação Elétrica , Feminino , Humanos , Masculino , Nervo Mediano/fisiologia , Nervo Radial/fisiologia , Período Refratário Eletrofisiológico/fisiologia
9.
Neuroreport ; 12(2): 349-52, 2001 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-11209948

RESUMO

Human scalp-derived somatosensory evoked potentials (SEP) elicited by median nerve stimulation contain an early (20 ms latency) high-frequency (600 Hz) wavelet burst which is supposed to reflect non-invasively the timing of rapidly repeating population spikes in thalamocortical afferences and/or the receiving neocortical cell populations. This burst is superimposed onto the slower (< or = 100 Hz) primary cortical response (N20) representing intracortically generated postsynaptic events. The present study addressed the temporal dynamics and correlation of these response components in awake human subjects and found that at a 3 min time scale the burst response was significantly more variable than the concomitant N20, and that the burst and N20 varied independently of each other. Thus, wavelet burst and N20 represent parallel and partly independent steps in sensory processing at cortical input stages in awake human subjects. We propose that the N20 represents a stable somatosensory input whereas the more fluctuating high-frequency burst could index variable modes of processing, such as a floating focus of attention.


Assuntos
Nível de Alerta/fisiologia , Córtex Cerebral/fisiologia , Potenciais Somatossensoriais Evocados/fisiologia , Potenciais Pós-Sinápticos Excitadores/fisiologia , Adolescente , Adulto , Idoso , Anticonvulsivantes/administração & dosagem , Carbamazepina/administração & dosagem , Epilepsia/tratamento farmacológico , Epilepsia/fisiopatologia , Potenciais Somatossensoriais Evocados/efeitos dos fármacos , Potenciais Pós-Sinápticos Excitadores/efeitos dos fármacos , Feminino , Humanos , Masculino , Nervo Mediano/fisiologia , Pessoa de Meia-Idade , Fases do Sono/fisiologia , Ácido Valproico/administração & dosagem
10.
Neurosci Lett ; 256(2): 101-4, 1998 Nov 06.
Artigo em Inglês | MEDLINE | ID: mdl-9853713

RESUMO

Human median nerve somatosensory evoked potentials contain a burst of high-frequency (600 Hz) wavelets superimposed on the primary cortical response (N20). These presumably reflect highly-synchronized repetitive thalamic and/or intracortical population spike bursts and are diminished in non-REM sleep with N20 persisting. Here the burst/N20 relation in awake subjects was examined by using eight different intensities of electric median nerve stimuli. In all subjects the amplitude recruitment of both N20 and burst could be modeled adequately as a sigmoidal function of stimulus intensity. While 8/10 subjects showed a parallel recruitment, 2/10 subjects required significantly higher stimulation intensities for burst than for N20 recruitment. This dampened burst recruitment possibly reflects slight vigilance fluctuations in open-eyed awake subjects; a further increase of burst thresholds could explain the burst attenuation when entering shallow sleep.


Assuntos
Córtex Cerebral/fisiologia , Potenciais Somatossensoriais Evocados/fisiologia , Nervo Mediano/fisiologia , Adulto , Feminino , Humanos , Masculino , Distribuição Aleatória , Detecção de Recrutamento Audiológico , Processamento de Sinais Assistido por Computador , Decúbito Dorsal , Fatores de Tempo , Estimulação Elétrica Nervosa Transcutânea , Vigília/fisiologia
11.
Neurosci Lett ; 286(2): 83-6, 2000 Jun 02.
Artigo em Inglês | MEDLINE | ID: mdl-10825642

RESUMO

Non-invasive scalp-recordings of human somatosensory evoked potentials (SEP) contain high-frequency (600 Hz) wavelet bursts, presumably generated by synchronized thalamocortical and/or intracortical population spikes. Here, double pulse stimulation (interval 20 ms) in 12 healthy subjects revealed significantly different burst recovery for mixed vs. sensory-only nerves. For median nerves the second burst response was decreased (11/11 subjects), possibly due to interfering reafferent (e.g. muscle spindle) input. In contrast, for sensory-only superficial radial nerves (containing less fibers than median nerves), weak bursts were detected in 6/11 subjects and were found fully recovered in 4/6 subjects. This potential for rapid burst recovery at 20 ms intervals renders contributions from neurons emitting bursts based on slowly recovering low-threshold calcium spikes unlikely and favors the generation of macroscopic SEP bursts by specialized cell populations, e.g. inhibitory interneurons and/or chattering cells the latter of which are capable to discharge rapidly repeating (50 Hz) high-frequency (600 Hz) bursts of fast sodium spikes.


Assuntos
Potenciais Somatossensoriais Evocados/fisiologia , Condução Nervosa/fisiologia , Neurônios Aferentes/fisiologia , Nervos Periféricos/fisiologia , Córtex Somatossensorial/fisiologia , Potenciais de Ação/fisiologia , Estimulação Elétrica , Eletroencefalografia , Humanos , Nervo Mediano/fisiologia , Vias Neurais/citologia , Vias Neurais/fisiologia , Neurônios Aferentes/citologia , Nervos Periféricos/citologia , Nervo Radial/fisiologia , Córtex Somatossensorial/citologia , Fatores de Tempo
12.
Neurosci Lett ; 234(2-3): 131-4, 1997 Oct 03.
Artigo em Inglês | MEDLINE | ID: mdl-9364515

RESUMO

Based on low-noise superconducting quantum interference devices (SQUIDs) magnetoencephalography allows the non-invasive detection of low-amplitude high-frequency brain responses evoked about 20 ms after electric hand nerve stimulation. The main spectral energy of these brief oscillatory bursts (near 600 Hz) is in the range typical for rapidly repeated action potentials. Here, the magnetic fields of median and ulnar nerve evoked 600 Hz bursts are shown to exhibit a somatotopic arrangement at the primary somatosensory hand cortex closely resembling that of the concomitant postsynaptic primary cortical response (¿N20m'). Two possible burst generators are discussed: (1) repetitive spike volleys conducted along the terminal segments of somatotopically arranged thalamocortical axons, and (2) early intracortical spike activity in nerve-specific subterritories of the 3b hand area.


Assuntos
Mapeamento Encefálico/métodos , Mãos/inervação , Magnetoencefalografia , Córtex Somatossensorial/fisiologia , Humanos , Oscilometria
13.
Phys Med Biol ; 46(11): 2873-87, 2001 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-11720352

RESUMO

Standard methods for artefact removal in MEG or EEG measurements consist of rejection of either corrupted epochs or signal space projection (SSP). We propose to combine the two methods by applying SSP only in corrupted epochs and thus using both temporal and spatial information. This partial signal space projection necessarily results in smaller variances for the source localization. Formulae for dipole localization errors as a function of fraction of corrupted epochs are derived and verified in Monte Carlo simulations of MEG measurements corrupted with eye artefacts. A theoretical analysis of various measuring devices, classes of artefact and locations of dipole of interest shows that the proposed method leads to significant improvement for frontal signal dipoles and for 30-80% corrupted epochs.


Assuntos
Magnetoencefalografia/instrumentação , Magnetoencefalografia/métodos , Algoritmos , Simulação por Computador , Campos Eletromagnéticos , Olho/patologia , Humanos , Modelos Teóricos , Método de Monte Carlo , Reprodutibilidade dos Testes , Processamento de Sinais Assistido por Computador , Fatores de Tempo
14.
IEEE Trans Biomed Eng ; 47(10): 1347-55, 2000 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-11059169

RESUMO

High-resolution magnetoencephalography (MEG) allows for a detailed description of focal neuronal current sources going far beyond the dipole approximation which merely indicates the center and magnitude of neuronal activity. Higher order multipole coefficients can be related to other bulk properties, like spatial extent or curvature. The possibility and limitations of measuring spatial extent by interpreting reconstructed multipole coefficients was tested under realistic noise conditions and for model misspecifications; for this analysis the primary cortical response ("N20") to electric median nerve stimulation was modeled by a one dimensional source distribution. The forward calculation was done analytically up to octapolar order for a spherical volume conductor. The multipole expansion is shown to estimate the lateral source extent with negligible bias; this estimate is to first-order stable against additional source features, like gyral curvature or spatial extent in a second direction (gyral depth, neuronal length). For a dipole moment of 20 nAm a lateral extent of 2 cm can be detected for a realistic noise level with large but experimentally still reasonable effort. Approximating a realistic head model by a sphere results in errors larger than the extent to be estimated; accordingly, studies on human cortical evoked responses will require multipole fitting in realistic head models.


Assuntos
Magnetoencefalografia , Modelos Neurológicos , Córtex Somatossensorial/fisiologia , Humanos , Processamento de Sinais Assistido por Computador
15.
IEEE Trans Biomed Eng ; 46(4): 400-8, 1999 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-10217878

RESUMO

The consequences of artifact suppression by means of signal-space projection on dipole localization accuracy for magnetoencephalography measurements are studied. Approximate analytical formulas, equivalent to the Cramer-Rao bound, are presented and verified by Monte Carlo simulations which relate the increase of localization error for individual coordinates to the similarity of the artifact field and respective (contravariant) quadrupole fields obtained by differentiating the dipole field with respect to its origin. The expressions simplify significantly for dipoles placed below the center of the measuring system giving rise to highly symmetric field patterns. Formulas are presented both for single- and for multiple-artifact rejection. As illustrative examples artifact fields are constructed which a) lead to highly decreasing signal-to-noise ratio and goodness-of-fit (GOF), while the localization error is unaffected for all coordinates and b) lead to an increase of localization error while the SNR and the GOF stays constant. Finally, the rich structure of localization error increase is demonstrated for a class of artifact fields originating from artifact current dipoles.


Assuntos
Magnetoencefalografia , Modelos Cardiovasculares , Processamento de Sinais Assistido por Computador , Artefatos , Teorema de Bayes , Campos Eletromagnéticos , Funções Verossimilhança , Modelos Estatísticos
16.
IEEE Trans Biomed Eng ; 47(1): 75-87, 2000 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-10646282

RESUMO

Artifacts in magnetoneurography data due to endogenous biological noise sources, like the cardiac signal, can be four orders of magnitude higher than the signal of interest. Therefore, it is important to establish effective artifact reduction methods. We propose a blind source separation algorithm using only second-order temporal correlations for cleaning biomagnetic measurements of evoked responses in the peripheral nervous system. The algorithm showed its efficiency by eliminating disturbances originating from biological and technical noise sources and successfully extracting the signal of interest. This yields a significant improvement of the neuro-magnetic source analysis.


Assuntos
Técnicas de Diagnóstico Neurológico , Potenciais Somatossensoriais Evocados , Processamento de Sinais Assistido por Computador , Algoritmos , Artefatos , Estimulação Elétrica , Humanos , Vértebras Lombares , Magnetoencefalografia , Radiculopatia/diagnóstico , Nervo Tibial/fisiologia , Fatores de Tempo
17.
Phys Rev E Stat Nonlin Soft Matter Phys ; 64(1 Pt 2): 016112, 2001 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-11461336

RESUMO

Using Gaussian kernels to define the correlation sum we derive simple formulas that correct the noise bias in estimates of the correlation dimension and K2 entropy of chaotic time series. The corrections are only based on the difference of correlation dimensions for adjacent embedding dimensions and hence preserve the full functional dependencies on both the scale parameter and embedding dimension. It is shown theoretically that the estimates, which are derived for additive white Gaussian noise, are also robust for moderately colored noise. Simulations underline the usefulness of the proposed correction schemes. It is demonstrated that the method gives satisfactory results also for non-Gaussian and dynamical noise.

18.
Nuklearmedizin ; 27(4): 140-6, 1988 Aug.
Artigo em Alemão | MEDLINE | ID: mdl-3263624

RESUMO

A new iterative strategy for determination of the source distribution in single-photon emission tomography (SPECT) simulates mathematically the scintigraphic imaging process during direction sum computation. Limited spatial resolution and gamma-ray attenuation are taken into account using simplifying approximations. Highly resolved low-noise tomograms without obvious artifacts are obtained. Results of phantom measurements as well as cases of thyroid and brain perfusion imaging are presented to demonstrate the capabilities of the method.


Assuntos
Tomografia Computadorizada de Emissão/métodos , Transtornos Cerebrovasculares/diagnóstico por imagem , Bócio Nodular/diagnóstico por imagem , Humanos , Modelos Estruturais
19.
Acta Anaesthesiol Belg ; 40(3): 187-94, 1989.
Artigo em Inglês | MEDLINE | ID: mdl-2510446

RESUMO

Adequate nutritional support is an important goal for the management of burn patients. Caloric requirements are higher than in any other major trauma or disease. The development of hypermetabolism and hypercatabolism leads to an increase in resting energy expenditure which depends on the severity of the injury. Therefore, with the intent to counteract these developments and their complications, a balanced carbohydrate, fat and protein intake should be adjusted to the actual needs. This paper gives a survey of the metabolic consequences of burns, reviews the underlying pathophysiology and tries to give practical guidelines for the nutritional support of the burn patient.


Assuntos
Queimaduras/fisiopatologia , Ingestão de Energia , Necessidades Nutricionais , Metabolismo dos Carboidratos , Metabolismo Energético , Nutrição Enteral/métodos , Feminino , Humanos , Metabolismo dos Lipídeos , Masculino , Nutrição Parenteral/métodos , Proteínas/metabolismo
20.
Patol Fiziol Eksp Ter ; (1): 17-20, 1999.
Artigo em Russo | MEDLINE | ID: mdl-10199168

RESUMO

Modification of a model allergen ovalbumin (OA) with succinylation led to a decrease of its allergenicity measured by passive cutaneous anaphylaxis reaction, RAST inhibition assay and basophil histamine release. Modified OA stimulated OA-specific T-cell hybrid 3DO-548 to produce IL-2 at the same level as in case of non-modified OA. Modified OA did not induce anti-OA IgE, but did induce anti-OA IgG antibodies. This approach to chemical modification of allergen-selective blockade of B-cell epitopes while not affecting T-cell epitopes suggests new opportunities in creation of safe and effective allergovaccines.


Assuntos
Alérgenos/efeitos dos fármacos , Epitopos/efeitos dos fármacos , Alérgenos/imunologia , Animais , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Endogâmicos CBA , Estimulação Química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA