RESUMO
PURPOSE: Interstitial lung disease (ILD) is the most common non-musculoskeletal manifestation of idiopathic inflammatory myopathies (IIM). Identification of body composition change may enable early intervention to improve prognosis. We investigated muscle quantity and quality derived from cross-sectional imaging in IIM, and its relationship to ILD severity. METHODS: A retrospective cohort study assessing IIM of ILD patients (n = 31) was conducted. Two datasets separated in time were collected, containing demographics, biochemical data, pulmonary function testing and thoracic CT data. Morphomic analysis of muscle quantity (cross-sectional area) and quality (density in Hounsfield Units) on thoracic CT were analysed utilising a web-based tool allowing segmentation of muscle and fat. Bilateral erector spinae and pectoralis muscle (ESM&PM) were measured at defined vertebral levels. RESULTS: FVC and DLCO decreased but within acceptable limits of treatment response (FVC: 83.7-78.7%, p < 0.05, DLCO 63.4-60.6%, p < 0.05). The cross-sectional area of the PM and ESM increased (PM: 39.8 to 40.7 cm2, p = 0.491; ESM: 35.2 to 39.5 cm2, p = 0.098). Density significantly fell for both the PM and ESM (PM: 35.3-31 HU, p < 0.05; ESM: 38-33.7, p < 0.05). Subcutaneous fat area increased from 103.9 to 136.1 cm2 (p < 0.05), while the visceral fat area increased but not reaching statistical significance. The change in PM density between time points demonstrated an inverse correlation with DLCO (p < 0.05, R = - 0.49). CONCLUSION: Patients with IIM ILD demonstrated significant body composition changes on CT imaging unlikely to be detected by traditional measurement tools. An increase in muscle area with an inverse decrease in density suggests poor muscle quality.
Assuntos
Doenças Pulmonares Intersticiais , Miosite , Humanos , Estudos Retrospectivos , Miosite/complicações , Doenças Pulmonares Intersticiais/diagnóstico por imagem , Doenças Pulmonares Intersticiais/etiologia , PrognósticoRESUMO
Background and aims: Computed tomography (CT), often more accessible than magnetic resonance imaging (MRI), remains widely used though radiation exposure is an obvious disadvantage. We previously showed that modern CT technology can achieve over 70% reduction in radiation-dose without loss of accuracy. Here, we compare low- versus conventional-dose CT in patients with known Crohn's disease to assess clinical confidence and accuracy of the low-dose procedure in the semi-acute setting.Methods: A comparative study of low-dose CT with full iterative reconstruction (IR) versus conventional-dose CT was conducted in 50 consecutive outpatients with Crohn's disease. Clinicians were provided with the low-dose images and reports, whereas conventional-dose images were reviewed after 4 weeks.Results: The clinical question was adequately addressed with low-dose IR imaging in all cases. Complications of Crohn's were detected in 37/50 (74%) with no disagreement between low- and conventional-dose imaging. The effective radiation dose reduction was 76.5% (low-dose mean 2.15 mSv versus conventional-dose CT 6.99 mSv).Conclusion: Low-dose IR CT is safe and accurate for evaluating distribution and complications of known Crohn's disease in the outpatient setting. We propose that low-dose radiation imaging should be adopted as standard-of-care for the evaluation of Crohn's disease and an acceptable alternative to MR particularly in the acute setting. ClinicalTrials.gov: NCT03140306.
Assuntos
Doença de Crohn , Exposição à Radiação , Tomografia Computadorizada por Raios X/efeitos adversos , Tomografia Computadorizada por Raios X/métodos , Doença de Crohn/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Doses de RadiaçãoRESUMO
OBJECTIVE. Cystic fibrosis (CF) is a multisystemic life-limiting disorder. The leading cause of morbidity in CF is chronic pulmonary disease. Chest CT is the reference standard for detection of bronchiectasis. Cumulative ionizing radiation limits the use of CT, particularly as treatments improve and life expectancy increases. The purpose of this article is to summarize the evidence on low-dose chest CT and its effect on image quality to determine best practices for imaging in CF. CONCLUSION. Low-dose chest CT is technically feasible, reduces dose, and renders satisfactory image quality. There are few comparison studies of low-dose chest CT and standard chest CT in CF; however, evidence suggests equivalent diagnostic capability. Low-dose chest CT with iterative reconstructive algorithms appears superior to chest radiography and equivalent to standard CT and has potential for early detection of bronchiectasis and infective exacerbations, because clinically significant abnormalities can develop in patients who do not have symptoms. Infection and inflammation remain the primary causes of morbidity requiring early intervention. Research gaps include the benefits of replacing chest radiography with low-dose chest CT in terms of improved diagnostic yield, clinical decision making, and patient outcomes. Longitudinal clinical studies comparing CT with MRI for the monitoring of CF lung disease may better establish the complementary strengths of these imaging modalities.
Assuntos
Fibrose Cística/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Bronquiectasia/diagnóstico por imagem , Bronquiectasia/etiologia , Fibrose Cística/complicações , Feminino , Humanos , Pulmão/diagnóstico por imagem , Masculino , Doses de Radiação , Adulto JovemRESUMO
Thoracic computed tomography (CT) is the imaging reference method in the diagnosis, assessment and management of lung disease. In the setting of cystic fibrosis (CF), CT demonstrates increased sensitivity compared with pulmonary function tests and chest radiography, and findings correlate with clinical outcomes. Better understanding of the aetiology of CF lung disease indicates that even asymptomatic infants with CF can have irreversible pulmonary pathology. Surveillance and early diagnosis of lung disease in CF are important to preserve lung parenchyma and to optimise long-term outcomes. CF is associated with increased cumulative radiation exposure due to the requirement for repeated imaging from a young age. Radiation dose optimisation, important for the safe use of CT in children with CF, is best achieved in a team environment where paediatric radiologists work closely with paediatric respiratory physicians, physicists and radiography technicians to achieve the best patient outcomes. Despite the radiation doses incurred, CT remains a vital imaging tool in children with CF. Radiologists with special interests in CT dose optimisation and respiratory disease are key to the appropriate use of CT in paediatric imaging. Paediatric radiologists strive to minimise radiation dose to children whilst providing the best possible assessment of lung disease.
Assuntos
Fibrose Cística/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Exposição à Radiação/efeitos adversos , Tomografia Computadorizada por Raios X/métodos , Adolescente , Criança , Fibrose Cística/patologia , Diagnóstico por Imagem/métodos , Humanos , Lactente , Doses de Radiação , Radiografia Torácica/métodosRESUMO
OBJECTIVES: Performance of a modified abdominopelvic CT protocol reconstructed using full iterative reconstruction (IR) was assessed for imaging patients presenting with acute abdominal symptoms. MATERIALS AND METHODS: Fifty-seven patients (17 male, 40 female; mean age of 56.5 ± 8 years) were prospectively studied. Low-dose (LD) and conventional-dose (CD) CTs were contemporaneously acquired between November 2015 and March 2016. The LD and CD protocols imparted radiation exposures approximating 10-20% and 80-90% those of routine abdominopelvic CT, respectively. The LD images were reconstructed with model-based iterative reconstruction (MBIR), and CD images with hybrid IR (40% adaptive statistical iterative reconstruction (ASIR)). Image quality was assessed quantitatively and qualitatively. Independent clinical interpretations were performed with a 6-week delay between reviews. RESULTS: A 74.7% mean radiation dose reduction was achieved: LD effective dose (ED) 2.38 ± 1.78 mSv (size-specific dose estimate (SSDE) 3.77 ± 1.97 mGy); CD ED 7.04 ± 4.89 mSv (SSDE 10.74 ± 5.5 mGy). LD-MBIR images had significantly lower objective and subjective image noise compared with CD-ASIR (p < 0.0001). Noise reduction for LD-MBIR studies was greater for patients with BMI < 25 kg/m2 than those with BMI ≥ 25 kg/m2 (5.36 ± 3.2 Hounsfield units (HU) vs. 4.05 ± 3.1 HU, p < 0.0001). CD-ASIR studies had significantly better contrast resolution, and diagnostic acceptability (p < 0.0001 for all). LD-MBIR studies had significantly lower streak artifact (p < 0.0001). There was no difference in sensitivity for primary findings between the low-dose and conventional protocols with the exception of one case of enteritis. CONCLUSIONS: Low-dose abdominopelvic CT performed with MBIR is a feasible radiation dose reduction strategy for imaging patients presenting with acute abdominal pain.
Assuntos
Abdome Agudo/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Meios de Contraste , Diatrizoato de Meglumina , Feminino , Humanos , Iohexol , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Doses de Radiação , Sensibilidade e EspecificidadeRESUMO
OBJECTIVES: There is potential for high radiation exposure during neurointerventional procedures. Increasing regulatory requirements mandate dose monitoring of patients and staff, and justification of high levels of radiation exposure. This paper demonstrates the potential to use radiation dose-tracking software to establish local diagnostic reference levels. METHODS: Consecutive neurointerventional procedures, performed in a single institution within a one-year period, were retrospectively studied. Dose area product (DAP) data were collected using dose-tracking software and clinical data obtained from a prospectively generated patient treatment database. RESULTS: Two hundred and sixty-four procedures met the selection criteria. Median DAP was 100 Gy.cm2 for aneurysm coiling procedures, 259 Gy.cm2 for arteriovenous malformation (AVM) embolisation procedures, 87 Gy.cm2 for stroke thrombolysis/thrombectomy, and 74 Gy.cm2 for four-vessel angiography. One hundred and nine aneurysm coiling procedures were further studied. Six significant variables were assessed using stepwise regression analysis to determine effect on DAP. Aneurysm location (anterior vs posterior circulation) had the single biggest effect (p = 0.004). CONCLUSIONS: This paper confirms variable radiation exposures during neurointerventional procedures. The 75th percentile (used to define diagnostic reference levels) of DAP measurements represents a reasonable guidance metric for monitoring purposes. Results indicate that aneurysm location has the greatest impact on dose during coiling procedures and that anterior and posterior circulation coiling procedures should have separate diagnostic reference levels. KEY POINTS: ⢠Dose-tracking software is useful for monitoring patient radiation dose during neurointerventional procedures ⢠This paper provides a template for methodology applicable to any interventional suite ⢠Local diagnostic reference levels were defined by using the 75th percentile of DAP as per International Commission on Radiological Protection recommendations ⢠Aneurysm location is the biggest determinant of radiation dose during coiling procedures. ⢠Anterior and posterior circulation coiling procedures should have separate diagnostic reference levels.
Assuntos
Transtornos Cerebrovasculares/diagnóstico por imagem , Doses de Radiação , Exposição à Radiação/estatística & dados numéricos , Monitoramento de Radiação/métodos , Radiografia Intervencionista , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Transtornos Cerebrovasculares/terapia , Feminino , Fluoroscopia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Estudos Retrospectivos , Software , Adulto JovemRESUMO
1. CT is superior to pulmonary function tests and chest radiography for the assessment and monitoring of cystic fibrosis (CF)-related lung disease and, also, of pediatric bronchiectasis not caused by CF (hereafter referred to as non-CF bronchiectasis). 2. Low-dose CT protocols that impart radiation doses similar to those used in chest radiography are feasible for the surveillance of patients with bronchiectasis. 3. Chest radiography is still most commonly used as the first-line imaging examination of choice for the assessment of acute complications related to bronchiectasis. 4. Pulmonary MRI, with or without the use of inhaled hyperpolarized gas, can be performed to obtain functional information, and, in dedicated centers, it may yield imaging results comparable to those obtained by CT. 5. Gastrointestinal and pancreaticobiliary manifestations of CF are observed with greater frequency in adults, because of increased life expectancy.
Assuntos
Bronquiectasia/diagnóstico , Fibrose Cística/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Bronquiectasia/diagnóstico por imagem , Criança , Fibrose Cística/diagnóstico , Fibrose Cística/fisiopatologia , Humanos , Pulmão/fisiopatologia , Imageamento por Ressonância Magnética , Testes de Função Respiratória , Tomografia Computadorizada por Raios XRESUMO
OBJECTIVE: The purpose of this study was to analyze the performance of pure model-based iterative reconstruction (MBIR) in low-dose CT enterography. SUBJECTS AND METHODS: Forty-four patients with Crohn disease referred for CT enterography were included. Low-dose modified-protocol and conventional-protocol CT datasets were contemporaneously acquired. Conventional-protocol image formation was performed with 40% adaptive statistical iterative reconstruction (ASIR). Modified-protocol data were reconstructed with 100% MBIR and 40% ASIR. Image quality was assessed subjectively and objectively at six levels. Independent clinical interpretations by two fully blinded radiologists were compared with reference standard consensus reviews by two nonblinded readers who had access to clinical information, previous imaging studies, and medical records. RESULTS: A 74.7% average radiation dose reduction was seen: low-dose modified-protocol effective dose, 1.61 ± 1.18 mSv (size-specific-dose-estimate, 2.47 ± 1.21 mGy); conventional-protocol effective dose, 6.05 ± 2.84 mSv (size-specific-dose-estimate, 9.25 ± 2.9 mGy). Image quality assessment yielded 9372 data points. Objective noise on modified-protocol MBIR images was superior (p < 0.05) to that with the conventional protocol at three of six levels and comparable at the other three levels. Modified-protocol images were superior to conventional-protocol ASIR images (p < 0.05 in all cases) for subjective noise, spatial resolution, contrast resolution, streak artifact, and diagnostic acceptability on coronal reconstructions. Axial diagnostic acceptability was superior for conventional-protocol ASIR (p = 0.76). For both readers, modified-protocol MBIR clinical readings agreed more closely with reference standard readings than did conventional-protocol ASIR readings with regard to bowel wall disease assessment (κ = 0.589 and 0.700 vs 0.583 and 0.564). Overall Crohn disease activity grade (κ = 0.549 and 0.441 vs 0.315 and 0.596) and detection of acute complications (κ = 1.0 and 0.689 vs 0.896 and 0.896) were comparable when evaluated on conventional-protocol ASIR and modified-protocol MBIR images. CONCLUSION: Low-dose CT enterography with MBIR yields images that are comparable to or superior to conventional images.
Assuntos
Doença de Crohn/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Algoritmos , Feminino , Humanos , Masculino , Modelos Estatísticos , Estudos Prospectivos , Doses de RadiaçãoRESUMO
BACKGROUND: Computed tomography (CT) helps physicians locate and diagnose pathological conditions. In some conditions, having an airway segmentation method which facilitates reconstruction of the airway from chest CT images can help hugely in the assessment of lung diseases. Many efforts have been made to develop airway segmentation algorithms, but methods are usually not optimized to be reliable across different CT scan parameters. METHODS: In this paper, we present a simple and reliable semi-automatic algorithm which can segment tracheal and bronchial anatomy using the open-source 3D Slicer platform. The method is based on a region growing approach where trachea, right and left bronchi are cropped and segmented independently using three different thresholds. The algorithm and its parameters have been optimized to be efficient across different CT scan acquisition parameters. The performance of the proposed method has been evaluated on EXACT'09 cases and local clinical cases as well as on a breathing pig lung phantom using multiple scans and changing parameters. In particular, to investigate multiple scan parameters reconstruction kernel, radiation dose and slice thickness have been considered. Volume, branch count, branch length and leakage presence have been evaluated. A new method for leakage evaluation has been developed and correlation between segmentation metrics and CT acquisition parameters has been considered. RESULTS: All the considered cases have been segmented successfully with good results in terms of leakage presence. Results on clinical data are comparable to other teams' methods, as obtained by evaluation against the EXACT09 challenge, whereas results obtained from the phantom prove the reliability of the method across multiple CT platforms and acquisition parameters. As expected, slice thickness is the parameter affecting the results the most, whereas reconstruction kernel and radiation dose seem not to particularly affect airway segmentation. CONCLUSION: The system represents the first open-source airway segmentation platform. The quantitative evaluation approach presented represents the first repeatable system evaluation tool for like-for-like comparison between different airway segmentation platforms. Results suggest that the algorithm can be considered stable across multiple CT platforms and acquisition parameters and can be considered as a starting point for the development of a complete airway segmentation algorithm.
Assuntos
Algoritmos , Broncografia , Processamento de Imagem Assistida por Computador/métodos , Software , Tomografia Computadorizada por Raios X , Traqueia/diagnóstico por imagem , Animais , Brônquios/fisiologia , Humanos , Respiração , Suínos , Traqueia/fisiologiaRESUMO
PURPOSE: Pure iterative reconstruction (Pure IR) has been proposed as a solution to improve diagnostic quality of low dose CT images. We assess the performance of model based iterative reconstruction (MBIR) in improving conventional dose CT enterography (CTE) images. METHODS: 43 Crohn's patients (27 female) (38.5 ± 12.98 years) referred for CTE were included. Images were reconstructed with pure IR (MBIR, General Electric Healthcare) in addition to standard department protocol (reconstructed with hybrid iterative reconstruction (Hybrid IR) [60% filtered back projection/40% adaptive statistical IR (General Electric Healthcare)]. Image quality was assessed objectively and subjectively at 6 anatomical levels. Clinical interpretation was undertaken in consensus by 2 blinded radiologists along with 2 non-blinded readers ('gold standard'). Results were analyzed using Statistical Package for Social Scientists. RESULTS: Mean effective radiation dose was 6.05 ± 2.84 mSv (size specific dose estimates 9.25 ± 2.9 mGy). Objective and subjective assessment yielded 6106 data points. Pure IR images significantly outperformed those using standard reconstruction techniques across all subjective (p < 0.001 for all comparisons) (noise, contrast resolution, spatial resolution, streak artifact, axial diagnostic acceptability, coronal diagnostic acceptability) and objective (p < 0.004) (noise, signal-to-noise ratio) parameters. Clinical reads of the pure IR images agreed more closely with the gold standard reads than the hybrid IR image reads in terms of overall Crohn's activity grade (κ = 0.630, 0.308) and detection of acute complications (κ = 1.0, 0.896). Results were comparable for bowel wall disease severity assessment (κ = 0.523, 0.593). CONCLUSIONS: Pure IR considerably improves image quality of conventional dose CTE images and therefore its use should be expanded beyond low dose protocols to improving image quality at conventional dose CT imaging.
Assuntos
Doença de Crohn/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador , Tomografia Computadorizada por Raios X , Adolescente , Adulto , Idoso , Meios de Contraste , Feminino , Trato Gastrointestinal/diagnóstico por imagem , Humanos , Iohexol , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Intensificação de Imagem Radiográfica , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto JovemRESUMO
PURPOSE OF REVIEW: Radiologic investigations continue to play a pivotal role in the diagnosis of pathologic conditions of the small intestine despite enhancement of capsule endoscopy and double-balloon endoscopy. Imaging techniques continue to evolve and new techniques in MRI in particular, are being developed. RECENT FINDINGS: Continued advances in computed tomography (CT) and MRI techniques have reinforced the importance of these imaging modalities in small bowel assessment. The more invasive enteroclysis technique yields better small bowel distension for both CT and MRI when compared with peroral enterography, but no clinically significant difference is seen in terms of diagnostic accuracy. Recent concern regarding radiation exposure means that MRI is gaining in popularity. Fluoroscopic studies such as barium follow through and small bowel enteroclysis are being replaced by the cross-sectional alternatives. Contrast-enhanced ultrasound is showing results comparable with CT and MRI, but concern remains regarding reproducibility, especially outside centres that specialize in advanced sonographic techniques. SUMMARY: CT and MRI enterography are comparable first-line modalities for patients with suspected small bowel disease, but magnetic resonance enterography is favoured given the absence of ionizing radiation. Capsule endoscopy is a reasonable alternative investigation in exploration of chronic gastrointestinal blood loss, but is best kept as a second-line test in patients with other symptoms.
Assuntos
Enteropatias/diagnóstico , Intestino Delgado/diagnóstico por imagem , Endoscopia por Cápsula/métodos , Técnicas de Diagnóstico do Sistema Digestório , Humanos , Intestino Delgado/patologia , Imageamento por Ressonância Magnética/métodos , Doses de Radiação , Tomografia Computadorizada por Raios X/métodosRESUMO
PURPOSE: Computed tomography (CT)-guided core needle biopsy (CNB) can be affected by streak artifact obscuring the needle tip. This study investigates factors that influence the occurrence and severity of streak artifact during CNB. MATERIALS AND METHODS: Eight coaxial guide needles of two sizes from two manufacturers with and without stylets were imaged in a CT phantom, with CT reconstructed with adaptive statistical iterative reconstruction and filtered back projection. CNB-related streak artifact was quantified with profile analysis in an image-processing program. Differences between maximum attenuation at the needle tip and minimum attenuation in the streak artifact were compared for each variable. Diagnostic acceptability and streak artifact were subjectively assessed on each phantom image and on 40 clinical CNB procedures by three independent blinded reviewers following training case review. RESULTS: Artifact was significantly less with the central stylet removed versus in situ (median, 1,145 HU vs 3,390 HU; P < .001) for all needles, and less for 19-gauge needles versus 17-gauge needles (median, 1,334 HU vs 2,780 HU, respectively; P = .006). There were no differences based on manufacturer (P = .906) or reconstruction algorithm (P = .524). Independent reviews found that streak artifact was significantly reduced when the central stylet was removed (κ = 0.875-1.0; P < .001), and needle tip position was better in cases in which the stylet was removed (κ = 0.231-0.711; P < .001). CONCLUSIONS: Streak artifact can be reduced and needle tip visualization improved by confirming final biopsy needle position with the central stylet removed on CT and using smaller-gauge guide needles.
Assuntos
Artefatos , Processamento de Imagem Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Biópsia com Agulha de Grande Calibre/instrumentação , Biópsia com Agulha de Grande Calibre/métodos , Biópsia por Agulha , Biópsia Guiada por Imagem/instrumentação , Biópsia Guiada por Imagem/métodos , Variações Dependentes do Observador , Imagens de FantasmasRESUMO
Educational Objectives and Key Points. 1. Given that abdominal hernias are a frequent imaging finding, radiologists not only are required to interpret the appearances of abdominal hernias but also should be comfortable with identifying associated complications and postrepair findings. 2. CT is the imaging modality of choice for the assessment of a known adult abdominal hernia in both elective and acute circumstances because of rapid acquisition, capability of multiplanar reconstruction, good spatial resolution, and anatomic depiction with excellent sensitivity for most complications. 3. Ultrasound is useful for adult groin assessment and is the imaging modality of choice for pediatric abdominal wall hernia assessment, whereas MRI is beneficial when there is reasonable concern that a patient's symptoms could be attributable to a hernia or a musculoskeletal source. 4. Fluoroscopic herniography is a sensitive radiologic investigation for patients with groin pain in whom a hernia is suspected but in whom a hernia cannot be identified at physical examination. 5. The diagnosis of an internal hernia not only is a challenging clinical diagnosis but also can be difficult to diagnose with imaging: Closed-loop small-bowel obstruction and abnormally located bowel loops relative to normally located small bowel or colon should prompt assessment for an internal hernia.
Assuntos
Hérnia Abdominal/diagnóstico , Adulto , Idoso , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Radiografia Abdominal/métodos , Tomografia Computadorizada por Raios X/métodosRESUMO
Key points. 1. CT is used to confirm the diagnosis of acute pancreatitis when the diagnosis is in doubt and to differentiate acute interstitial pancreatitis from necrotizing pancreatitis, which is a key element of the updated Atlanta nomenclature. The acute interstitial variety accounts for 90-95% of cases, with acute necrotizing pancreatitis accounting for the remaining cases. 2. Necrosis due to acute pancreatitis is best assessed on IV contrast-enhanced CT performed 40 seconds after injection. Peripancreatic necrosis is a subtype of necrotizing pancreatitis in which tissue death occurs in peripancreatic tissues. This is seen in isolation in 20% of patients with necrotizing pancreatitis. 3. Simple fluid collections associated with acute interstitial pancreatitis are subdivided chronologically. A collection observed within approximately 4 weeks of acute pancreatitis onset is termed an "acute peripancreatic fluid collection (APFC)." A collection older than 4 weeks should have a thin wall and is termed a "pseudocyst." Both APFCs and pseudocysts can be infected or sterile. 4. Fluid collections associated with necrotizing pancreatitis are labeled on the basis of age and the presence of a capsule. Within 4 weeks of acute pancreatitis onset, a fluid collection associated with necrotizing pancreatitis is termed an "acute necrotic collection (ANC)" whereas an older collection is termed an area of "walled-off necrosis (WON)" if it has a perceptible wall on CT. The term "pseudocyst" is not used in the setting of necrotizing pancreatitis collections. Although an ANC and a (WON can be infected or sterile, infection is far more likely compared with acute interstitial pancreatitis collections. 5. The severity of acute pancreatitis is graded on the basis of the presence of acute complications or organ failure. Mild acute pancreatitis has neither acute complications nor organ failure. Moderate-severity acute pancreatitis is associated with acute complications or organ failure lasting fewer than 48 hours. Severe acute pancreatitis is characterized by single- or multiorgan failure persisting for greater than 48 hours.
Assuntos
Guias como Assunto , Pancreatite/classificação , Pancreatite/diagnóstico por imagem , Terminologia como Assunto , Tomografia Computadorizada por Raios X/normas , Doença Aguda , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estados UnidosRESUMO
OBJECTIVE: Iterative reconstruction (IR) allows diagnostic CT imaging with less radiation exposure than filtered back projection (FBP). We studied an IR low-dose CT abdomen/pelvis (LDCTAP) protocol, designed to image at an effective dose (ED) approximating 1 mSv in patients with Crohn's disease (CD). METHODS: Forty patients, mean age 37 ± 13.4 years (range 17-69), with CD underwent two synchronous CT protocols (conventional-dose (CDCTAP) and LDCTAP). CDCTAP and LDCTAP images were compared for diagnostic acceptability, yield, image quality and ED (in millisieverts). The optimal level of IR for LDCTAP was also studied. RESULTS: LDCTAP yielded a mean ED of 1.3 ± 0.8 mSv compared with 4.7 ± 2.9 mSv for CDCTAP, reducing ED by 73.7 ± 3.3 % (mean dose reduction, 3.5 ± 2.1 mSv; P < 0.001) and dose length product by 73.6 ± 2.6 % (P < 0.001). Sub-millisievert (0.84 mSv) imaging was performed for patients with a body mass index (BMI) less than 25 (i.e. 63 % of our cohort). LDCTAP resulted in increased image noise and reduced diagnostic acceptability compared with CDCTAP despite use of IR, but detection of extra-luminal complications was comparable. CONCLUSION: Patients with suspected active CD can be adequately imaged using LDCTAP, yielding comparable information regarding extent, activity and complications of CD compared with CDCTAP, but with 74 % less dose. LDCTAP at doses equivalent to that of two abdominal radiographs represents a feasible alternative to CDCTAP. KEY POINTS: ⢠Radiation dose is a concern when imaging patients with Crohn's disease. ⢠New techniques allow low-dose abdominopelvic CT with acceptable image quality. ⢠Using hybrid iterative reconstruction, its diagnostic yield compares well with that of conventional CT. ⢠Sub-millisievert CT of patients with Crohn's disease appears technically and clinically feasible.
Assuntos
Doença de Crohn/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiografia Abdominal/métodos , Tomografia Computadorizada por Raios X/métodos , Adolescente , Adulto , Idoso , Meios de Contraste/química , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pelve/diagnóstico por imagem , Estudos Prospectivos , Doses de Radiação , Proteção Radiológica/métodos , Reprodutibilidade dos Testes , Adulto JovemRESUMO
OBJECTIVE: Radiologic percutaneous gastrostomy tube placement is a widely accepted method of enteral access for patients requiring long-term nutritional support for a variety of conditions. Although the safety of this procedure is well documented, complications do occur. The purpose of this article is to review the major and minor complications associated with gastrostomy tube placement and to present appropriate and effective management strategies. CONCLUSION: Familiarity with the potential complications, techniques for their prevention, and strategies for treatment will help practicing interventional radiologists successfully manage all possible outcomes.
Assuntos
Nutrição Enteral/métodos , Gastrostomia/métodos , Complicações Pós-Operatórias , Radiologia Intervencionista , HumanosRESUMO
BACKGROUND: Medical radiation exposure is of increasing concern in patients with cystic fibrosis (PWCF) due to improving life expectancy. We aimed to assess and quantify the cumulative effective dose (CED) in PWCF in the context of CFTR-modulator therapy and the advancement of dose reduction techniques. METHODS: We performed a retrospective observational study in a single University CF centre over a 11-year period. We included PWCF, aged over 18 years who exclusively attended our institution. Relevant clinical data (demographics, transplantation history and modulator status) and radiological data (modality, quantity, and radiation exposure measured as CED) were collected. For those on modulator therapy the quantified imaging and radiation data was dichotomised into pre-and-post therapy periods. RESULTS: The study included 181 patients: 139 on CFTR modulator therapy, 15 transplant recipients and 27 with neither exposure. 82% of patients received <25 mSv over the study period. Mean study duration was 6.9 ± 2.6 years pre-modulation and 4.2 ± 2.6 years post-modulation. Pre-modulation CT contributed 9.6% of total chest imaging (n = 139/1453) and 70.9% of the total CED. Post-modulation CT use increased contributing 42.7% of chest imaging (n = 444/1039) and comprised 75.8% of CED. Annual CED was 1.55 mSv pre and 1.36 mSv post modulation (p = 0.41). Transplant recipients had an annual CED of 64 ± 36.1mSv. CONCLUSION: Chest CT utilisation for PWCF is rising in our institution, replacing chest radiography amidst CFTR-modulation. Despite the increasing use of CT, no significant radiation dose penalty was observed with a reduction in mean annual CED, primarily due to the influence of CT dose reduction strategies.
Assuntos
Fibrose Cística , Humanos , Adulto , Pessoa de Meia-Idade , Fibrose Cística/diagnóstico por imagem , Regulador de Condutância Transmembrana em Fibrose Cística/genética , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Radiografia , TóraxRESUMO
PURPOSE: To critically evaluate the current literature in an effort to establish the current role of radiologic imaging (computed tomography, magnetic resonance imaging, ultrasonography [US], fluoroscopy, conventional film radiography) in irritable bowel syndrome (IBS). MATERIALS AND METHODS: The term "irritable bowel syndrome" was used to search Clinical Evidence, UpToDate, Cochrane Library, TRIP, and National Institute for Health and Clinical Excellence databases and the American College of Physicians Journal Club and Evidence-Based Medicine online. PubMed was searched by using medical subject headings ("irritable bowel syndrome;" "colonic diseases, functional;" "diagnosis;" "colonography;" "computed tomographic (CT)") and the dates January 1, 1985 to July 1, 2010. Appraisal was independently performed by two reviewers who followed the Oxford Centre for Evidence Based Medicine practice criteria. RESULTS: No systematic review (SR) specifically examined radiologic imaging in IBS; however, in the secondary literature, five relevant SRs or guidelines partially addressed this topic. A PubMed search identified 1451 articles, 111 of which at least partially addressed radiologic imaging. Of these, seven valid articles (two SRs and five primary research articles) were identified. The five primary research articles examined either colonic investigations (colonoscopy and barium enema examination) (n=5) or US (n=2) or both (n=2). Structural disease found infrequently in patients with IBS-type symptoms included diverticulosis, colorectal cancer, celiac disease, inflammatory bowel disease, and ovarian cancer. The incidence of structural disease in patients with concerning symptoms was low. CONCLUSION: Although widely used, there is a surprising paucity of evidence guiding radiologic imaging in IBS. Radiologic imaging may not be required in patients with IBS without potentially concerning symptoms but should be considered where such symptoms exist, and choice of imaging study should be influenced by predominant symptoms. Definitive recommendations must await further research.
Assuntos
Diagnóstico por Imagem/estatística & dados numéricos , Medicina Baseada em Evidências , Síndrome do Intestino Irritável/diagnóstico , Síndrome do Intestino Irritável/epidemiologia , Ensaios Clínicos como Assunto , Humanos , Prevalência , Reprodutibilidade dos Testes , Sensibilidade e EspecificidadeRESUMO
PURPOSE: Assess the effect of filtered back projection (FBP) and hybrid (adaptive statistical iterative reconstruction [ASIR]) and pure (model-based iterative reconstruction [MBIR]) iterative reconstructions on abdominal computed tomography (CT) acquired with 75% radiation dose reduction. MATERIALS AND METHODS: In an institutional review board-approved prospective study, 10 patients (mean [standard deviation] age, 60 (8) years; 4 men and 6 women) gave informed consent for acquisition of additional abdominal images on 64-slice multidetector-row CT (GE 750HD, GE Healthcare). Scanning was repeated over a 10-cm scan length at 200 and 50 milliampere second (mA s), with remaining parameters held constant at 120 kilovolt (peak), 0.984:1 pitch, and standard reconstruction kernel. Projection data were deidentified, exported, and reconstructed to obtain 4 data sets (200-mA s FBP, 50-mA s FBP, 50-mA s ASIR, 50-mA s MBIR), which were evaluated by 2 abdominal radiologists for lesions and subjective image quality. Objective noise and noise spectral density were measured for each image series. RESULTS: Among the 10 patients, the maximum weight recorded was 123 kg, with maximum transverse diameter measured as 43.7 cm. Lesion conspicuity at 50-mA s MBIR was better than on 50-mA s FBP and ASIR images (P < 0.01). Image noise was rated as suboptimal on low-dose FBP and ASIR but deemed acceptable in MBIR images. Objective noise with 50-mA s MBIR was 2 to 3 folds lower compared to 50-mA s ASIR, 50-mA s FBP, and 200-mA s FBP (P < 0.0001). Noise spectral density analyses demonstrated that ASIR retains the noise spectrum signature of FBP, whereas MBIR has much lower noise with a more regularized noise spectrum pattern. CONCLUSION: Model-based iterative reconstruction renders acceptable image quality and diagnostic confidence in 50- mA s abdominal CT images, whereas FBP and ASIR images are associated with suboptimal image quality at this radiation dose level.
Assuntos
Processamento de Imagem Assistida por Computador/métodos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiografia Abdominal/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos ProspectivosRESUMO
BACKGROUND: Thyroid drains following thyroid surgery are routinely used despite minimal supportive evidence. Our aim in this study is to determine the impact of routine open drainage of the thyroid bed postoperatively on ultrasound-determined fluid accumulation at 24 hours. METHODS: We conducted a prospective randomised clinical trial on patients undergoing thyroid surgery. Patients were randomly assigned to a drain group (n = 49) or a no-drain group (n = 44) immediately prior to wound closure. Patients underwent a neck ultrasound on day 1 and day 2 postoperatively. After surgery, we evaluated visual analogue scale pain scores, postoperative analgesic requirements, self-reported scar satisfaction at 6 weeks and complications. RESULTS: There was significantly less mean fluid accumulated in the drain group on both day 1, 16.4 versus 25.1 ml (P-value = 0.005), and day 2, 18.4 versus 25.7 ml (P-value = 0.026), following surgery. We found no significant differences between the groups with regard to length of stay, scar satisfaction, visual analogue scale pain score and analgesic requirements. There were four versus one wound infections in the drain versus no-drain groups. This finding was not statistically significant (P = 0.154). No life-threatening bleeds occurred in either group. CONCLUSIONS: Fluid accumulation after thyroid surgery was significantly lessened by drainage. However, this study did not show any clinical benefit associated with this finding in the nonemergent setting. Drains themselves showed a trend indicating that they may augment infection rates. The results of this study suggest that the frequency of acute life-threatening bleeds remains extremely low following abandoning drains. We advocate abandoning routine use of thyroid drains. TRIAL REGISTRATION: ISRCTN94715414.