Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Gastrointest Endosc ; 2024 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-38935016

RESUMO

BACKGROUND AND AIMS: Training in interventional endoscopy is offered by nonaccredited advanced endoscopy fellowship programs (AEFPs). The number of these programs has increased dramatically with a concurrent increase in the breadth and complexity of interventional endoscopy procedures. Accreditation is governed by competency-based education, yet what constitutes a "high-quality" nonaccredited AEFP has not been defined. Using an evidence-based consensus process, we aimed to establish standards for AEFPs. METHODS: The RAND UCLA appropriateness method, a well-described modified Delphi process to develop quality indicators, was used. A task force established by the American Society for Gastrointestinal Endoscopy drafted potential quality indicators (structure, process, and outcome) in 6 categories: activity preceding training; structure of AEFPs; training in ERCP, EUS, and EMR; and luminal stent placement. Three rounds of iterative feedback from 20 experts were conducted. Round 0 involved discussion of project details. In round 1, experts independently ranked proposed quality indicators on a 9-point interval scale ranging from highly inappropriate (1) to highly appropriate (9). Next, proposed quality indicators were discussed and reworded in a group meeting followed by round 2, in which experts independently reranked proposed quality indicators and provided benchmarks (when applicable). The median score for each quality indicator was calculated. Mean absolute deviation from the median was calculated, and appropriateness of potential quality indicators was assessed using the BIOMED concerted action on appropriateness definition, P value method, and interpercentile range adjusted for symmetry definition. A quality indicator was deemed appropriate if the median score was ≥7 and met criteria for appropriateness using all 3 defined statistical methods. RESULTS: Of 89 proposed quality indicators, 37 statements met criteria as appropriate for a quality indicator (activity preceding training, 2; structure of AEFPs, 10; training in ERCP, 7; training in EUS, 8; training in EMR, 7; luminal stent placement, 3). Minimum thresholds were defined for 19 relevant quality indicators for number of trainers, procedures during fellowship, and procedures before assessment of competence. Among the final appropriate quality indicators were that all trainees should undergo qualitative and quantitative competence assessments using validated tools at least quarterly with documented feedback throughout the training period and that trainees should track outcomes and relevant quality metrics for specific procedures. CONCLUSIONS: This consensus process using validated methodology established standards for an AEFP in an effort to ensure adequate training in the most commonly taught interventional endoscopic procedures (ERCP, EUS, EMR, and luminal stent placement) during fellowship. An important component of an AEFP is the use of competency-based assessments that are compliant with the Accreditation Council for Graduate Medical Education's Next Accreditation System, with the goal of ensuring that trainees achieve specific milestones in their progression to achieving cognitive and technical competency.

2.
Inj Prev ; 2024 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-39107100

RESUMO

OBJECTIVE: To quantify the unintentional injuries associated with housing elements among older adults treated in US hospital emergency departments (EDs). To identify modifiable home hazards. METHODS: The National Electronic Injury Surveillance System (NEISS) coding manual was reviewed to identify all codes associated with housing elements that were permanently attached to a home. We queried the 2020 NEISS data for older adults (aged 65 and older) to determine the number of injuries associated with each element. The 10 elements involved in the most hospitalisations and the most ED visits were each tabulated by the number of records in the NEISS sample and national estimate, yielding two separate lists of 10 housing elements. A review of case narratives was conducted on a random selection constituting 10% of all records or a minimum of 100 records to determine common precipitating factors and prevention recommendations. RESULTS: From the two lists, we identified 11 housing elements most commonly associated with housing-related injuries, resulting in ED visits or hospitalisations. The housing element most associated with housing-related injuries was floor, leading to 929 937 ED visits. Subsequent case narrative review yielded prevention recommendations, including modifications that support balance and fall recovery, reduce the need to reach and improve visibility. CONCLUSIONS: Housing element-related injuries affect hundreds of thousands of older adults. Case narratives reveal falls, tripping/slipping and sliding injuries that can potentially be prevented with home modification. NEISS is a valuable tool to identify injury risks in the home.

3.
Am J Gastroenterol ; 118(4): 615-626, 2023 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-36219171

RESUMO

INTRODUCTION: Most patients with esophageal adenocarcinoma (EAC) do not have a previous diagnosis of Barrett's esophagus (BE), demonstrating a failure of current screening practices. An understanding of patient attitudes and barriers is essential to develop and implement interventions to improve BE screening adherence. METHODS: We conducted a Web-based survey of patients aged >50 years with chronic gastroesophageal reflux disease at 3 academic medical centers and 1 affiliated safety net health systems. Survey domains included patient characteristics, endoscopy history, familiarity with screening practices, perceived BE/EAC risk, and barriers to screening. RESULTS: We obtained a response rate of 22.6% (472/2,084) (74% men, mean age 67.9 years). Self-identified race and ethnicity of participants was 66.5% non-Hispanic White, 20.0% non-Hispanic Black, 13.4% other race, and 7.1% Hispanic. Screening for BE was recommended in only 13.2%, and only 5.3% reported previous screening. Respondents had notable gaps in knowledge about screening indications; only two-thirds correctly identified BE risk factors and only 19.5% believed BE screening was needed for gastroesophageal reflux disease. More than 1 in 5 respondents believed they would get BE (31.9%) or EAC (20.2%) but reported barriers to screening. Compared with White respondents, more Black respondents were concerned about getting BE/EAC and interested in screening but report higher barriers to screening. DISCUSSION: Patients at risk for BE, particularly racial and ethnic minorities, are worried about developing EAC but rarely undergo screening and have poor understanding of screening recommendations.


Assuntos
Esôfago de Barrett , Neoplasias Esofágicas , Refluxo Gastroesofágico , Masculino , Humanos , Idoso , Feminino , Esôfago de Barrett/diagnóstico , Esôfago de Barrett/patologia , Neoplasias Esofágicas/patologia , Fatores de Risco , Refluxo Gastroesofágico/diagnóstico , Refluxo Gastroesofágico/complicações , Percepção
4.
Nanomaterials (Basel) ; 9(3)2019 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-30845655

RESUMO

The fact that structural RNA motifs can direct RNAs to fold and self-assemble into predictable pre-defined structures is an attractive quality and driving force for RNA's use in nanotechnology. RNA's recognized diversity concerning cellular and synthetically selected functionalities, however, help explain why it continues to draw attention for new nano-applications. Herein, we report the modification of a bifurcated reporter system based on the previously documented Spinach aptamer/DFHBI fluorophore pair that affords the ability to confirm the assembly of contiguous RNA strands within the context of the previously reported multi-stranded RNA nanoring. Exploration of the sequence space associated with the base pairs flanking the aptamer core demonstrate that fluorescent feedback can be optimized to minimize the fluorescence associated with partially-assembled RNA nanorings. Finally, we demonstrate that the aptamer-integrated nanoring is capable of assembling directly from transcribed DNA in one pot.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA