Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 135
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Diabet Med ; : e15384, 2024 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-38923618

RESUMO

AIMS: In tackling rising diabetes-related emergencies, the need to understand and address emergency service usage by people with type 1 diabetes is vital. This review aimed to quantify current trends in presentations for type 1 diabetes-related emergencies and identify public health strategies that reduce the frequency of diabetes-related emergencies and improve glycaemic management. METHODS: Medline (OVID), Cochrane and CINAHL were searched for studies published between 2000 and 2023, focusing on people with type 1 diabetes, severe hypoglycaemia and/or diabetic ketoacidosis, and ambulance and/or emergency department usage. There were 1313 papers identified, with 37 publications meeting review criteria. RESULTS: The incidence of type 1 diabetes-related emergencies varied from 2.4 to 14.6% over one year for hypoglycaemic episodes, and between 0.07 and 11.8 events per 100 person-years for hyperglycaemic episodes. Notably, our findings revealed that ongoing diabetes education and the integration of diabetes technology, such as continuous glucose monitoring and insulin pump therapy, significantly reduced the incidence of these emergencies. However, socio-economic disparities posed barriers to accessing these technologies, subsequently shifting the cost to emergency healthcare and highlighting the need for governments to consider subsidising these technologies as part of preventative measures. CONCLUSIONS: Improving access to continuous glucose monitoring and insulin pump therapy, in combination with ongoing diabetes education focusing on symptom recognition and early management, will reduce the incidence of diabetes-related emergencies. Concurrent research assessing emergency healthcare usage patterns during the implementation of such measures is essential to ensure these are cost-effective.

2.
Diabet Med ; 41(3): e15195, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37562414

RESUMO

AIMS: To examine the psychometric properties of the Diabetes Management Experiences Questionnaire (DME-Q). Adapted from the validated Glucose Monitoring Experiences Questionnaire, the DME-Q captures satisfaction with diabetes management irrespective of treatment modalities. METHODS: The DME-Q was completed by adults with type 1 diabetes as part of a randomized controlled trial comparing hybrid closed loop (HCL) to standard therapy. Most psychometric properties were examined with pre-randomization data (n = 149); responsiveness was examined using baseline and 26-week follow-up data (n = 120). RESULTS: Pre-randomization, participants' mean age was 44 ± 12 years, 52% were women. HbA1c was 61 ± 11 mmol/mol (7.8 ± 1.0%), diabetes duration was 24 ± 12 years and 47% used an insulin pump prior to the trial. A forced three-factor analysis revealed three expected domains, that is, 'Convenience', 'Effectiveness' and 'Intrusiveness', and a forced one-factor solution was also satisfactory. Internal consistency reliability was strong for the three subscales ( α range = 0.74-0.84) and 'Total satisfaction' ( α = 0.85). Convergent validity was demonstrated with moderate correlations between DME-Q 'Total satisfaction' and diabetes distress (PAID: rs = -0.57) and treatment satisfaction (DTSQ; rs = 0.58). Divergent validity was demonstrated with a weak correlation with prospective/retrospective memory (PRMQ: rs = -0.16 and - 0.13 respectively). Responsiveness was demonstrated, as participants randomized to HCL had higher 'Effectiveness' and 'Total satisfaction' scores than those randomized to standard therapy. CONCLUSIONS: The 22-item DME-Q is a brief, acceptable, reliable measure with satisfactory structural and construct validity, which is responsive to intervention. The DME-Q is likely to be useful for evaluation of new pharmaceutical agents and technologies in research and clinical settings.


Assuntos
Diabetes Mellitus Tipo 1 , Adulto , Humanos , Feminino , Pessoa de Meia-Idade , Masculino , Diabetes Mellitus Tipo 1/tratamento farmacológico , Automonitorização da Glicemia , Satisfação do Paciente , Psicometria , Reprodutibilidade dos Testes , Estudos Retrospectivos , Estudos Prospectivos , Glicemia , Inquéritos e Questionários
3.
Diabet Med ; 40(4): e15020, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36468784

RESUMO

AIM: To explore the lived experience of older adults with type 1 diabetes using closed-loop automated insulin delivery, an area previously receiving minimal attention. METHODS: Semi-structured interviews were conducted with adults aged 60 years or older with long-duration type 1 diabetes who participated in a randomised, open-label, two-stage crossover trial comparing first-generation closed-loop therapy (MiniMed 670G) versus sensor-augmented pump therapy. Interview recordings were transcribed, thematically analysed and assessed. RESULTS: Twenty-one older adults participated in interviews after using closed-loop therapy. Twenty were functionally independent, without frailty or major cognitive impairment; one was dependent on caregiver assistance, including for diabetes management. Quality of life benefits were identified, including improved sleep and reduced diabetes-related psychological burden, in the context of experiencing improved glucose levels. Gaps between expectations and reality of closed-loop therapy were also experienced, encountering disappointment amongst some participants. The cost was perceived as a barrier to continued closed-loop access post-trial. Usability issues were identified, such as disruptive overnight alarms and sensor inaccuracy. CONCLUSIONS: The lived experience of older adults without frailty or major cognitive impairment using first-generation closed-loop therapy was mainly positive and concordant with glycaemic benefits found in the trial. Older adults' lived experience using automated insulin delivery beyond trial environments requires exploration; moreover, the usability needs of older adults should be considered during future device development.


Assuntos
Diabetes Mellitus Tipo 1 , Fragilidade , Humanos , Idoso , Insulina/uso terapêutico , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemiantes/uso terapêutico , Qualidade de Vida , Resultado do Tratamento , Sistemas de Infusão de Insulina , Automonitorização da Glicemia , Estudos Cross-Over , Glicemia
4.
J Sleep Res ; : e14106, 2023 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-38050705

RESUMO

Hypoglycaemia during sleep is a common and clinically important issue for people living with insulin-treated diabetes. Continuous glucose monitoring devices can help to identify nocturnal hypoglycaemia and inform treatment strategies. However, sleep is generally inferred, with diabetes researchers and physicians using a fixed-overnight period as a proxy for sleep-wake status when analysing and interpretating continuous glucose monitoring data. No study to date has validated such an approach with established sleep measures. Continuous glucose monitoring and research-grade actigraphy devices were worn and sleep diaries completed for 2 weeks by 28 older adults (mean age 67 years [SD 5]; 17 (59%) women) with type 1 diabetes. Using continuous glucose monitoring data from a total of 356 nights, fixed-overnight (using the recommended period of 00:00 hours-06:00 hours) and objectively-measured sleep periods were compared. The fixed-overnight period approach missed a median 57 min per night (interquartile range: 49-64) of sleep for each participant, including five continuous glucose monitoring-detected hypoglycaemia episodes during objectively-measured sleep. Twenty-seven participants (96%) had at least 1 night with continuous glucose monitoring time-in-range and time-above-range discrepancies both ≥ 10 percentage points, a clinically significant discrepancy. The utility of fixed-overnight time continuous glucose monitoring as a proxy for sleep-awake continuous glucose monitoring is inadequate as it consistently excludes actual sleep time, obscures glycaemic patterns, and misses sensor hypoglycaemia episodes during sleep. The use of validated measures of sleep to aid interpretation of continuous glucose monitoring data is encouraged.

5.
BMC Health Serv Res ; 23(1): 1377, 2023 Dec 08.
Artigo em Inglês | MEDLINE | ID: mdl-38066492

RESUMO

BACKGROUND: Type 2 diabetes mellitus (T2DM) is highly prevalent within the Indigenous Australian community. Novel glucose monitoring technology offers an accurate approach to glycaemic management, providing real-time information on glucose levels and trends. The acceptability and feasibilility of this technology in Indigenous Australians with T2DM has not been investigated. OBJECTIVE: This feasibility phenomenological study aims to understand the experiences of Indigenous Australians with T2DM using flash glucose monitoring (FGM). METHODS: Indigenous Australians with T2DM receiving injectable therapy (n = 8) who used FGM (Abbott Freestyle Libre) for 6-months, as part of a clinical trial, participated in semi-structured interviews. Thematic analysis of the interviews was performed using NVivo12 Plus qualitative data analysis software (QSR International). RESULTS: Six major themes emerged: 1) FGM was highly acceptable to the individual; 2) FGM's convenience was its biggest benefit; 3) data from FGM was a tool to modify lifestyle choices; 4) FGM needed to be complemented with health professional support; 5) FGM can be a tool to engage communities in diabetes management; and 6) cost of the device is a barrier to future use. CONCLUSIONS: Indigenous Australians with T2DM had positive experiences with FGM. This study highlights future steps to ensure likelihood of FGM is acceptable and effective within the wider Indigenous Australian community.


Assuntos
Automonitorização da Glicemia , Diabetes Mellitus Tipo 2 , Humanos , Austrália , Glicemia/análise , Automonitorização da Glicemia/métodos , Diabetes Mellitus Tipo 2/terapia , Estudos de Viabilidade , Projetos Piloto , Povos Aborígenes Australianos e Ilhéus do Estreito de Torres
6.
Diabetes Spectr ; 36(2): 127-136, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37193203

RESUMO

Regular exercise is essential to overall cardiovascular health and well-being in people with type 1 diabetes, but exercise can also lead to increased glycemic disturbances. Automated insulin delivery (AID) technology has been shown to modestly improve glycemic time in range (TIR) in adults with type 1 diabetes and significantly improve TIR in youth with type 1 diabetes. Available AID systems still require some user-initiated changes to the settings and, in some cases, significant pre-planning for exercise. Many exercise recommendations for type 1 diabetes were developed initially for people using multiple daily insulin injections or insulin pump therapy. This article highlights recommendations and practical strategies for using AID around exercise in type 1 diabetes.

7.
Diabet Med ; 39(3): e14747, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34806780

RESUMO

AIM: To assess the cost-effectiveness of professional-mode flash glucose monitoring in adults with type 2 diabetes in general practice compared with usual clinical care. METHODS: An economic evaluation was conducted as a component of the GP-OSMOTIC trial, a pragmatic multicentre 12-month randomised controlled trial enrolling 299 adults with type 2 diabetes in Victoria, Australia. The economic evaluation was conducted from an Australian healthcare sector perspective with a lifetime horizon. Health-related quality of life (EQ-5D) and total healthcare costs were compared between the intervention and the usual care group within the trial period. The 'UKPDS Outcomes Model 2' was used to simulate post-trial lifetime costs, life expectancy and quality-adjusted life years (QALYs). RESULTS: No significant difference in health-related quality of life and costs was found between the two groups within the trial period. Professional-mode flash glucose monitoring yielded greater QALYs (0.03 [95% CI: 0.02, 0.04]) and a higher cost (A$3807 [95% CI: 3604, 4007]) compared with usual clinical care using a lifetime horizon under the trial-based monitoring frequency, considered not cost-effective (incremental cost-effectiveness ratio = A$120,228). The intervention becomes cost-effective if sensor price is reduced to lower than 50%, or monitoring frequency is decreased to once per year while maintaining the same treatment effect on HbA1c . CONCLUSIONS: Including professional-mode flash glucose monitoring every 3 months as part of a management plan for people with type 2 diabetes in general practice is not cost-effective, but could be if the sensor price or monitoring frequency can be reduced.


Assuntos
Automonitorização da Glicemia/métodos , Análise Custo-Benefício , Diabetes Mellitus Tipo 2/sangue , Medicina Geral , Idoso , Diabetes Mellitus Tipo 2/economia , Diabetes Mellitus Tipo 2/terapia , Feminino , Custos de Cuidados de Saúde , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica , Qualidade de Vida , Anos de Vida Ajustados por Qualidade de Vida , Vitória
8.
Diabet Med ; 39(9): e14907, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35757899

RESUMO

AIM: Hybrid closed-loop (HCL) therapy improves glycaemic control in adolescents with type 1 diabetes; however, little is known about their lived experience using these systems. The aim of this study was to explore the lived experiences of youth with type 1 diabetes using HCL therapy, and their parents, to provide insight into their lived experiences. METHODS: Adolescents and young adults aged 12-25 years, who used Medtronic MiniMed™ 670G HCL system during a 6-month randomised clinical trial, and their parents, were invited to participate in a semi-structured interview at the end of the study. Open-ended questions were used to explore the lived experiences of families using HCL. The interviews were audio-recorded, transcribed and analysed using thematic analysis to determine the main themes. RESULTS: In all, 17 young people with type 1 diabetes mean ± SD age: 17.5 ± 4.2 years, diabetes duration: 11.0 ± 4.9 years and HbA1c 64 ± 9 mmol/mol (8.0 ± 0.8%) and 10 parents were interviewed. Three themes were identified: (1) 'Developing confidence and trust in the system', (2) 'Reduction in anxiety' and (3) 'Issues with device'. They reported a positive experience using HCL, with improvements in glucose levels and increased independence with diabetes management. However, frustration around the number of alarms and notifications associated with the system were also identified as issues. CONCLUSION: Both youth and parents acknowledged the benefits of this first-generation HCL system in improving glycaemic outcomes and in providing flexibility and independence. These lived experiences provide valuable information in the introduction and provision of targeted education with HCL therapy.


Assuntos
Diabetes Mellitus Tipo 1 , Adolescente , Adulto , Glicemia/análise , Automonitorização da Glicemia , Diabetes Mellitus Tipo 1/tratamento farmacológico , Humanos , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Sistemas de Infusão de Insulina , Adulto Jovem
9.
Diabetes Obes Metab ; 24(6): 1143-1149, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35257468

RESUMO

AIM: To assess the feasibility of a prototype insulin infusion set (IIS) for extended wear in adults with type 1 diabetes. MATERIALS AND METHODS: The prototype Capillary Biomedical investigational extended-wear IIS (CBX IIS) incorporates a soft, flexible, reinforced kink-resistant angled nylon-derivative cannula with one distal and three proximal ports to optimize insulin delivery. Twenty adult participants with type 1 diabetes established on insulin pump therapy used the CBX IIS for two 7-day test periods while wearing a Dexcom G5 continuous glucose monitor. RESULTS: Participants were able to wear the CBX IIS for an average of 6.6 ± 1.4 days. Eighty-eight percent (36 of 41) of sets were worn for 7 days. No serious adverse events were reported. Five infusion sets failed prematurely because of: unresolvable hyperglycaemia (three); hyperglycaemia with elevated ketones (one); or infection (one). Median time in range (3.9-10.0 mmol/L) was 62% (54-76). Average glucose levels per day of infusion set wear showed a statistically significant increase over time (p < .001). CONCLUSIONS: Our preliminary observations confirm the tolerability of the prototype CBX IIS for extended wear, albeit with a deterioration in glucose control after the third day.


Assuntos
Diabetes Mellitus Tipo 1 , Hiperglicemia , Adulto , Glicemia , Diabetes Mellitus Tipo 1/tratamento farmacológico , Estudos de Viabilidade , Humanos , Hiperglicemia/prevenção & controle , Hipoglicemiantes/uso terapêutico , Insulina/efeitos adversos , Sistemas de Infusão de Insulina/efeitos adversos
10.
J Med Internet Res ; 24(4): e28901, 2022 04 08.
Artigo em Inglês | MEDLINE | ID: mdl-35394448

RESUMO

BACKGROUND: Monitoring glucose and other parameters in persons with type 1 diabetes (T1D) can enhance acute glycemic management and the diagnosis of long-term complications of the disease. For most persons living with T1D, the determination of insulin delivery is based on a single measured parameter-glucose. To date, wearable sensors exist that enable the seamless, noninvasive, and low-cost monitoring of multiple physiological parameters. OBJECTIVE: The objective of this literature survey is to explore whether some of the physiological parameters that can be monitored with noninvasive, wearable sensors may be used to enhance T1D management. METHODS: A list of physiological parameters, which can be monitored by using wearable sensors available in 2020, was compiled by a thorough review of the devices available in the market. A literature survey was performed using search terms related to T1D combined with the identified physiological parameters. The selected publications were restricted to human studies, which had at least their abstracts available. The PubMed and Scopus databases were interrogated. In total, 77 articles were retained and analyzed based on the following two axes: the reported relations between these parameters and T1D, which were found by comparing persons with T1D and healthy control participants, and the potential areas for T1D enhancement via the further analysis of the found relationships in studies working within T1D cohorts. RESULTS: On the basis of our search methodology, 626 articles were returned, and after applying our exclusion criteria, 77 (12.3%) articles were retained. Physiological parameters with potential for monitoring by using noninvasive wearable devices in persons with T1D included those related to cardiac autonomic function, cardiorespiratory control balance and fitness, sudomotor function, and skin temperature. Cardiac autonomic function measures, particularly the indices of heart rate and heart rate variability, have been shown to be valuable in diagnosing and monitoring cardiac autonomic neuropathy and, potentially, predicting and detecting hypoglycemia. All identified physiological parameters were shown to be associated with some aspects of diabetes complications, such as retinopathy, neuropathy, and nephropathy, as well as macrovascular disease, with capacity for early risk prediction. However, although they can be monitored by available wearable sensors, most studies have yet to adopt them, as opposed to using more conventional devices. CONCLUSIONS: Wearable sensors have the potential to augment T1D sensing with additional, informative biomarkers, which can be monitored noninvasively, seamlessly, and continuously. However, significant challenges associated with measurement accuracy, removal of noise and motion artifacts, and smart decision-making exist. Consequently, research should focus on harvesting the information hidden in the complex data generated by wearable sensors and on developing models and smart decision strategies to optimize the incorporation of these novel inputs into T1D interventions.


Assuntos
Diabetes Mellitus Tipo 1 , Hipoglicemia , Dispositivos Eletrônicos Vestíveis , Diabetes Mellitus Tipo 1/terapia , Glucose , Humanos , Insulina
11.
Diabet Med ; 38(11): e14608, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34043837

RESUMO

AIMS: Aim of this study is to report severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection, responsible for coronavirus disease 2019 (COVID-19), as a possible cause for type 1 diabetes by providing an illustrative clinical case of a man aged 45 years presenting with antibody-negative diabetic ketoacidosis post-recovery from COVID-19 pneumonia and to explore the potential for SARS-CoV-2 to adhere to human islet cells. METHODS: Explanted human islet cells from three independent solid organ donors were incubated with the SARS-CoV-2 spike protein receptor biding domain (RBD) fused to a green fluorescent protein (GFP) or a control-GFP, with differential adherence established by flow cytometry. RESULTS: Flow cytometry revealed dose-dependent specific binding of RBD-GFP to islet cells when compared to control-GFP. CONCLUSIONS: Although a causal basis remains to be established, our case and in vitro data highlight a potential mechanism by which SARS-CoV-2 infection may result in antibody-negative type 1 diabetes.


Assuntos
COVID-19/terapia , Diabetes Mellitus Tipo 1/diagnóstico , Cetoacidose Diabética/diagnóstico , Ilhotas Pancreáticas/metabolismo , SARS-CoV-2/metabolismo , Glicoproteína da Espícula de Coronavírus/metabolismo , COVID-19/complicações , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 1/etiologia , Cetoacidose Diabética/etiologia , Cetoacidose Diabética/terapia , Humanos , Técnicas In Vitro , Masculino , Pessoa de Meia-Idade
12.
Diabetes Obes Metab ; 22(7): 1111-1121, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32077207

RESUMO

AIM: To report the first study of temelimab, a monoclonal antibody neutralizing the pathogenic human endogenous retrovirus type W envelope, in patients with type 1 diabetes (T1D). MATERIALS AND METHODS: This double-blind, placebo-controlled, randomized clinical trial recruited adult patients with T1D within 4 years postdiagnosis and remaining C-peptide secretion. Sixty-four patients were randomized (2:1) to monthly temelimab 6 mg/kg or placebo during 24 weeks followed by a 24-week, open-label extension, during which all patients received temelimab. The primary objective was the safety and tolerability of temelimab. The secondary objective was to assess the pharmacodynamics response such as C-peptide levels, insulin use, HbA1c, hypoglycaemia and autoantibodies. RESULTS: Temelimab was well tolerated without any group difference in the frequency or severity of adverse events. Concerning exploratory endpoints, there was no difference in the levels of C-peptide, insulin use or HbA1c between treatment groups at weeks 24 and 48. The frequency of hypoglycaemia events was reduced with temelimab (P = 0.0004) at week 24 and the level of anti-insulin antibodies was lower with temelimab (P < 0.01); the other autoantibodies did not differ between groups. CONCLUSIONS: Temelimab appeared safe in patients with T1D. Pharmacodynamics signals (hypoglycaemia and anti-insulin antibodies) under temelimab were observed. Markers of ß-cell functions were not modified by treatment. These results need to be further explored in younger patients with T1D with earlier disease onset.


Assuntos
Diabetes Mellitus Tipo 1 , Retrovirus Endógenos , Adulto , Anticorpos Monoclonais/efeitos adversos , Anticorpos Monoclonais Humanizados , Diabetes Mellitus Tipo 1/tratamento farmacológico , Método Duplo-Cego , Humanos , Hipoglicemiantes
13.
BMC Fam Pract ; 20(1): 29, 2019 02 18.
Artigo em Inglês | MEDLINE | ID: mdl-30777033

RESUMO

BACKGROUND: Previous studies in general practice and hospital settings have identified that prescribing of non-insulin diabetes medications may be sub-optimal in people with type 2 diabetes (T2D) and renal impairment. Since these publications, a number of new medications have become available for the management of T2D. Study aims were to, in a cohort of Australians with T2D and renal impairment attending general practice, (1) investigate whether the prescribing of non-insulin diabetes medications is consistent with dosing adjustments recommended within current Australian Diabetes Society (ADS) guidelines; and (2) identify patient socio-demographic and clinical factors associated with at least one prescription of a non-insulin diabetes medication inconsistent with current ADS guidelines for medication doses. METHODS: Cross-sectional study using data from the MedicineInsight general practice database managed by NPS MedicineWise. Patients with T2D who were aged 18 years and over, with an average eGFR< 60 ml/min/1.73m2 and at least one prescription of a non-insulin diabetes medication between 1st January 2015 and 30th June 2017 were included. Descriptive statistics were used to summarise patient characteristics and medication use. Marginal logistic regression models were used to estimate associations between sociodemographic and clinical factors and prescribing of ≥1non-insulin diabetes medicine not consistent with ADS guidelines. RESULTS: The majority of the 3505 patients included (90.4%) had an average eGFR of 30-59 ml/min/1.73m2. In terms of absolute numbers, metformin was the medication most frequently prescribed at a dose not consistent with current ADS guidelines for dosing in renal impairment (n = 1601 patients), followed by DPP4 inhibitors (n = 611) and sulphonylureas (n = 278). The drug classes with the highest proportion of prescriptions with dosage not consistent with ADS guidelines were SGLT2 inhibitors (83%), followed by biguanides (58%) and DPP4 inhibitors (46%). Higher HbA1c, longer known diabetes duration and diagnosis of retinopathy were associated with receiving ≥1prescription with a dosage not consistent with guidelines. CONCLUSIONS: Prescribing of non-insulin diabetes medications at doses inconsistent with current ADS guideline recommendations for dosing adjustments for people with renal impairment was common. Further research is needed to understand how general practitioners access, interpret and apply the ADS guidelines and the impact this may have on patient outcomes.


Assuntos
Diabetes Mellitus Tipo 2/tratamento farmacológico , Inibidores da Dipeptidil Peptidase IV/administração & dosagem , Medicina Geral , Hipoglicemiantes/administração & dosagem , Metformina/administração & dosagem , Insuficiência Renal Crônica/metabolismo , Inibidores do Transportador 2 de Sódio-Glicose/administração & dosagem , Compostos de Sulfonilureia/administração & dosagem , Idoso , Idoso de 80 Anos ou mais , Austrália , Estudos Transversais , Diabetes Mellitus Tipo 2/complicações , Diabetes Mellitus Tipo 2/metabolismo , Feminino , Taxa de Filtração Glomerular , Hemoglobinas Glicadas/metabolismo , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência Renal Crônica/complicações
14.
Diabetologia ; 61(9): 1918-1922, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29992370

RESUMO

AIMS/HYPOTHESIS: This multicentre randomised double-blind placebo-controlled clinical trial assessed the efficacy and safety of a methionine aminopeptidase 2 (MetAP2) inhibitor, beloranib, in individuals with obesity (BMI ≥30 kg/m2) and type 2 diabetes (HbA1c 53-97 mmol/mol [7-11%] and fasting glucose <15.6 mmol/l). METHODS: Participants were randomised (via a centralised interactive web response system) to placebo, 1.2 or 1.8 mg beloranib s.c. twice weekly for 26 weeks. Participants, investigators and the sponsor were blinded to group assignment. The primary endpoint was the change in weight from baseline to week 26. The trial was terminated early when beloranib development was stopped because of an imbalance of venous thromboembolism events in beloranib-treated individuals vs placebo that became evident during late-stage development of the drug. RESULTS: In total, 153 participants were randomised, 51 to placebo, 52 to 1.2 mg beloranib and 50 to 1.8 mg beloranib. In participants who completed week 26, the least squares mean ± SE weight change (baseline 111 kg) was -3.1 ± 1.2% with placebo (n = 22) vs -13.5 ± 1.1% and -12.7 ± 1.3% with 1.2 and 1.8 mg beloranib, respectively (n = 25; n = 19; p < 0.0001). The change in HbA1c (baseline 67 mmol/mol [8.3%]) was -6.6 ± 2.2 mmol/mol (-0.6 ± 0.2%) with placebo vs -21.9 ± 2.2 mmol/mol (-2.0 ± 0.2%) or -21.9 ± 3.3 mmol/mol (-2.0 ± 0.3%) with 1.2 or 1.8 mg beloranib (p < 0.0001), respectively. The most common beloranib adverse events were sleep related. One beloranib-treated participant experienced a non-fatal pulmonary embolism. CONCLUSIONS/INTERPRETATION: MetAP2 inhibitors represent a novel mechanism for producing meaningful weight loss and improvement in HbA1c. TRIAL REGISTRATION: ClinicalTrials.gov NCT02324491 FUNDING: The study was funded by Zafgen, Inc.


Assuntos
Aminopeptidases/antagonistas & inibidores , Cinamatos/uso terapêutico , Cicloexanos/uso terapêutico , Diabetes Mellitus Tipo 2/tratamento farmacológico , Diabetes Mellitus Tipo 2/metabolismo , Compostos de Epóxi/uso terapêutico , Metaloendopeptidases/antagonistas & inibidores , Sesquiterpenos/uso terapêutico , Adolescente , Adulto , Idoso , Aminopeptidases/metabolismo , Fármacos Antiobesidade/uso terapêutico , Glicemia/efeitos dos fármacos , Peso Corporal/efeitos dos fármacos , Método Duplo-Cego , Feminino , Glucose/metabolismo , Hemoglobinas Glicadas/metabolismo , Glicoproteínas , Humanos , Hipoglicemiantes/uso terapêutico , Masculino , Metaloendopeptidases/metabolismo , Metionil Aminopeptidases , Pessoa de Meia-Idade , Obesidade/tratamento farmacológico , Obesidade/metabolismo , Redução de Peso/efeitos dos fármacos , Adulto Jovem
15.
BMC Endocr Disord ; 18(1): 47, 2018 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-30031385

RESUMO

BACKGROUND: Optimal glycaemia, reflected by glycated haemoglobin (HbA1c) levels, is key in reducing type 2 diabetes (T2D) complications. However, most people with T2D have suboptimal recall and understanding of HbA1c. Continuous glucose monitoring (CGM) measures glucose levels every 5 to 15-min over days and may be more readily understood. Given that T2D is more common in lower socioeconomic settings, we aim to study relationships between socioeconomic status (SES) and percentage time in glucose target range (TIR) which is a key metric calculated from CGM. METHODS: Analysis of baseline data from the General Practice Optimising Structured MOnitoring To Improve Clinical outcomes (GP-OSMOTIC) randomised controlled trial (October 2016 - November 2017) of 300 people with T2D from 25 Victorian General Practices. FreeStyle Libre Pro® sensor patch was used for this study. SES was defined by the Index of Relative Socio-economic Disadvantage (IRSD) and educational attainment. Univariable and multivariable mixed-effects linear regression analyses controlling for age, BMI, diet, exercise and study arm were performed. RESULTS: One hundred and sixty-seven (60.1%) participants were male, the mean (SD) participant age was 61.0 (9.7) years, and the mean (SD) duration of CGM use was 12.3 (2.5) days. The 10th IRSD decile (least disadvantaged) was associated with a 15% higher TIR vs. the 1st decile (most disadvantaged) (95% CI 5, 25; p = 0.003) and a 0.6% lower HbA1c (95% CI 0.1, 1; p = 0.03). There was no evidence of an association between educational attainment and TIR/HbA1c. CONCLUSION: Higher SES measured at an area level is associated with better achievement of glycaemic target using complementary measures of HbA1c and TIR in the GP-OSMOTIC cohort. Given that TIR may be more easily used in patient education and self-management support compared to HbA1c values, the social gradient identified in TIR provides an opportunity for clinicians and policy makers to address health inequities in T2D. TRIAL REGISTRATION: Australian and New Zealand Clinical Trials Registry Trial ACTRN12616001372471 , prospective, Date registered 4/10/2016.


Assuntos
Glicemia/metabolismo , Diabetes Mellitus Tipo 2/sangue , Diabetes Mellitus Tipo 2/tratamento farmacológico , Hipoglicemiantes/administração & dosagem , Insulina/administração & dosagem , Planejamento de Assistência ao Paciente , Idoso , Austrália , Glicemia/efeitos dos fármacos , Automonitorização da Glicemia/instrumentação , Automonitorização da Glicemia/normas , Esquema de Medicação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Autocuidado/normas , Classe Social , Fatores de Tempo , Resultado do Tratamento
16.
Intern Med J ; 48(5): 499-508, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29464891

RESUMO

The advent of devices that can track interstitial glucose levels, which are closely related to blood glucose levels, on a near continuous basis, has facilitated better insights into patterns of glycaemia. Continuous glucose monitoring (CGM) therefore allows for more intensive monitoring of blood glucose levels and potentially improved glycaemic control. In the context of the announcement on 1 April 2017 that the Australian Government will fund CGM monitoring for people with type 1 diabetes under the age of 21 years, this paper provides a review of the evidence for CGM and some of the ongoing challenges. There is evidence that real-time CGM in type 1 diabetes improves HbA1c and hypoglycaemia, while in type 2 diabetes, the evidence is less robust. Initial barriers to widespread implementation of CGM included issues with accuracy and user friendliness; however, as the technology has evolved, these issues have largely improved. Ongoing barriers include cost, and weaker evidence for their benefit in certain populations such as those with type 2 diabetes and less glycaemic variability. CGM has the potential to reduce healthcare costs, although real-world studies, including cost-effectiveness analyses, are needed in this area.


Assuntos
Automonitorização da Glicemia/métodos , Glicemia/metabolismo , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 2/sangue , Automonitorização da Glicemia/economia , Automonitorização da Glicemia/tendências , Análise Custo-Benefício , Diabetes Mellitus Tipo 1/diagnóstico , Diabetes Mellitus Tipo 1/economia , Diabetes Mellitus Tipo 2/diagnóstico , Diabetes Mellitus Tipo 2/economia , Previsões , Índice Glicêmico/fisiologia , Humanos
17.
Intern Med J ; 48(2): 201-204, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29415350

RESUMO

We documented temporal changes in the use of lipid-lowering medications and achievement of cholesterol targets in an Australian diabetes clinic. The number of patients using lipid-lowering therapy for primary or secondary cardiovascular prevention increased from 6 to 69% between 1993-1995 and 2014-2016, which corresponded to a decrease in low-density lipoprotein cholesterol levels from 3.7 to 2.4 mmol/L (P < 0.01).


Assuntos
Anticolesterolemiantes/uso terapêutico , Doenças Cardiovasculares/prevenção & controle , LDL-Colesterol/efeitos dos fármacos , Diabetes Mellitus/tratamento farmacológico , Hipercolesterolemia/tratamento farmacológico , Adulto , Idoso , Idoso de 80 Anos ou mais , Anticolesterolemiantes/farmacologia , Doenças Cardiovasculares/sangue , Doenças Cardiovasculares/epidemiologia , LDL-Colesterol/sangue , Diabetes Mellitus/sangue , Diabetes Mellitus/epidemiologia , Feminino , Humanos , Hipercolesterolemia/sangue , Hipercolesterolemia/epidemiologia , Masculino , Pessoa de Meia-Idade , Prevenção Primária/métodos , Prevenção Secundária/métodos , Vitória/epidemiologia
18.
Intern Med J ; 48(9): 1080-1086, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29573166

RESUMO

BACKGROUND: In people with type 1 diabetes (T1D), nocturnal hypoglycaemia (NH) can be slept through and can cause seizures, arrhythmias and death. Hypoglycaemia avoidance can induce hyperglycaemia and ketosis. Patient behaviour impacts clinical outcomes and may be changed by education. AIM: To develop and utilise a survey to evaluate patient self-management of overnight glycaemia in adults with T1D. METHODS: Adults with T1D attending two Australian tertiary referral diabetes clinics completed a survey about their diabetes self-management and glycaemic control, including responses to hypothetical pre-bed blood glucose (BG) levels (4-20 mmol/L). Statistical analyses included t-tests, Chi square tests and ANOVA with significance considered at P < 0.05. RESULTS: There were 205 participants (103 females), with a mean (SD) age of 41 (17) years, T1D duration of 20 (16) years, HbA1c of 7.8(1.4)%, (61.3(8.2) mmol/mol), 38% on insulin pump therapy (CSII) and 36% with impaired hypoglycaemia awareness (IHA). Mean (SD) number of BG tests/day was 5.4 (2.7). Patients set higher BG target levels at bedtime and overnight: 7.5(1.4) and 7.1(1.3) mmol/L, respectively, compared to daytime (6.9(1.0); P < 0.0001 and P = 0.002 respectively). Only 36% of participants reported treating nocturnal hypoglycaemia (NH) with the recommended refined, then complex, carbohydrate. Only 28% of patients made safe choices in all bedtime BG scenarios, with higher rates for CSII users, P = 0.0005. Further education was desired by 32% of respondents, with higher rates in those with (44%) versus without IHA (25%), P = 0.006. CONCLUSIONS: Many adults with T1D have suboptimal knowledge and behaviour regarding overnight BG self-management. A survey, piloted herein, may facilitate the identification of patients who could benefit from further education.


Assuntos
Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/tratamento farmacológico , Conhecimentos, Atitudes e Prática em Saúde , Hipoglicemia/prevenção & controle , Hipoglicemiantes/administração & dosagem , Insulina/administração & dosagem , Adulto , Austrália/epidemiologia , Glicemia/análise , Feminino , Hemoglobinas Glicadas/análise , Humanos , Hipoglicemia/sangue , Sistemas de Infusão de Insulina , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Autorrelato , Autogestão
19.
Diabetes Obes Metab ; 19(9): 1317-1321, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28256054

RESUMO

Chronic hyperglycaemia and glucose variability are associated with the development of chronic diabetes-related complications. We conducted a pooled analysis of patient-level data from three 24-week, randomized, phase III clinical trials to evaluate the impact of lixisenatide (LIXI) on glycaemic variability (GV) vs placebo as add-on to basal insulin. The main outcome GV measures were standard deviation (s.d.), mean amplitude of glycaemic excursions (MAGE), mean absolute glucose (MAG) level, area under the curve for fasting glucose (AUC-F), and high (HBGI) and low blood glucose index (LBGI). The change in GV metrics over 24 weeks and relationships among baseline GV, patient characteristics and outcomes were assessed. Data were pooled from 1198 patients (665 LIXI, 533 placebo). Values for s.d., MAG level, MAGE, HBGI, and AUC-F significantly decreased with LIXI vs placebo, while LBGI values were unchanged. Higher baseline GV measures correlated with older age, longer type 2 diabetes duration, lower body mass index, higher baseline glycated/haemogobin, greater reduction in postprandial glucose (PPG) level, and higher rates of symptomatic hypoglycaemia. These data show that LIXI added to basal insulin significantly reduced GV and PPG excursions vs placebo, without increasing the risk of hypoglycaemia (LBGI).


Assuntos
Diabetes Mellitus Tipo 2/tratamento farmacológico , Receptor do Peptídeo Semelhante ao Glucagon 1/agonistas , Hiperglicemia/prevenção & controle , Hipoglicemia/prevenção & controle , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Peptídeos/uso terapêutico , Glicemia/análise , Automonitorização da Glicemia , Estudos de Coortes , Diabetes Mellitus Tipo 2/sangue , Método Duplo-Cego , Resistência a Medicamentos , Quimioterapia Combinada/efeitos adversos , Seguimentos , Receptor do Peptídeo Semelhante ao Glucagon 1/metabolismo , Hemoglobinas Glicadas/análise , Humanos , Hiperglicemia/fisiopatologia , Hipoglicemia/induzido quimicamente , Hipoglicemia/fisiopatologia , Hipoglicemiantes/efeitos adversos , Insulina/efeitos adversos , Análise de Intenção de Tratamento , Pessoa de Meia-Idade , Peptídeos/efeitos adversos , Reprodutibilidade dos Testes , Índice de Gravidade de Doença
20.
Aust J Prim Health ; 23(1): 23-30, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-27465014

RESUMO

The aim was to examine predictors of duration of inpatient hospital stay in people with diabetes mellitus to assist implementation of strategies to reduce hospital stay. This audit prospectively studied patients with diabetes mellitus admitted to a medical unit of an Australian community public hospital. Other outcome measures included glucose treatment optimisation and access to GP and diabetes-specific healthcare professionals. Comparison was made to patients without diabetes mellitus who were admitted concomitantly. Diabetes patients represented 26% of admissions over a 2-month period. In total, 73% had seen a GP within the prior 6 months. Patients with diabetes mellitus (n=79) had a median age of 69 years; 53% were male and median HbA1c was 65mmolmol-1 (8.1%). Diabetes mellitus was associated with a longer inpatient stay (P=0.03), particularly among patients admitted with vascular disease. Age >65 years and seeing <3 members of the community-based diabetes mellitus multidisciplinary team (MDT) in the 2-years pre-admission were independently associated with a longer stay (P=0.02). In total, 10% were referred to an endocrinologist on discharge. Involvement of more of the diabetes-specific MDT, with a skilled GP, in primary care is recommended as it may shorten inpatient hospital stay, improve glycaemia and reduce demand for limited specialist endocrinologists.


Assuntos
Diabetes Mellitus , Hospitais Públicos , Tempo de Internação , Austrália , Feminino , Hospitalização , Hospitais Públicos/estatística & dados numéricos , Humanos , Masculino , Atenção Primária à Saúde
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA