Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 142
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Ann Neurol ; 96(2): 247-261, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38771066

RESUMO

OBJECTIVE: Although astrocytic pathology is a pathological hallmark of progressive supranuclear palsy (PSP), its pathophysiological role remains unclear. This study aimed to assess astrocyte reactivity in vivo in patients with PSP. Furthermore, we investigated alterations in brain lactate levels and their relationship with astrocyte reactivity. METHODS: We included 30 patients with PSP-Richardson syndrome and 30 healthy controls; in patients, tau deposition was confirmed through 18F-florzolotau positron emission tomography. Myo-inositol, an astroglial marker, and lactate were quantified in the anterior cingulate cortex through magnetic resonance spectroscopy. We measured plasma biomarkers, including glial fibrillary acidic protein as another astrocytic marker. The anterior cingulate cortex was histologically assessed in postmortem samples of another 3 patients with PSP with comparable disease durations. RESULTS: The levels of myo-inositol and plasma glial fibrillary acidic protein were significantly higher in patients than those in healthy controls (p < 0.05); these increases were significantly associated with PSP rating scale and cognitive function scores (p < 0.05). The lactate level was high in patients, and correlated significantly with high myo-inositol levels. Histological analysis of the anterior cingulate cortex in patients revealed reactive astrocytes, despite mild tau deposition, and no marked synaptic loss. INTERPRETATION: We discovered high levels of astrocyte biomarkers in patients with PSP, suggesting astrocyte reactivity. The association between myo-inositol and lactate levels suggests a link between reactive astrocytes and brain energy metabolism changes. Our results indicate that astrocyte reactivity in the anterior cingulate cortex precedes pronounced tau pathology and neurodegenerative processes in that region, and affects brain function in PSP. ANN NEUROL 2024;96:247-261.


Assuntos
Astrócitos , Proteína Glial Fibrilar Ácida , Giro do Cíngulo , Inositol , Ácido Láctico , Paralisia Supranuclear Progressiva , Humanos , Paralisia Supranuclear Progressiva/metabolismo , Paralisia Supranuclear Progressiva/diagnóstico por imagem , Paralisia Supranuclear Progressiva/patologia , Astrócitos/metabolismo , Astrócitos/patologia , Masculino , Feminino , Idoso , Pessoa de Meia-Idade , Proteína Glial Fibrilar Ácida/metabolismo , Proteína Glial Fibrilar Ácida/sangue , Ácido Láctico/sangue , Ácido Láctico/metabolismo , Inositol/metabolismo , Giro do Cíngulo/metabolismo , Giro do Cíngulo/diagnóstico por imagem , Giro do Cíngulo/patologia , Biomarcadores/sangue , Proteínas tau/metabolismo , Tomografia por Emissão de Pósitrons
2.
Cancer Sci ; 115(1): 227-236, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37994570

RESUMO

Charged particle beams induce various biological effects by creating high-density ionization through the deposition of energy along the beam's trajectory. Charged particle beams composed of neon ions (20 Ne10+ ) hold great potential for biomedical applications, but their physiological effects on living organs remain uncertain. In this study, we demonstrate that neon-ion beams expedite the process of reoxygenation in tumor models. We simulated mouse SCCVII syngeneic tumors and exposed them to either X-ray or neon-ion beams. Through an in vivo radiobiological assay, we observed a reduction in the hypoxic fraction in tumors irradiated with 8.2 Gy of neon-ion beams 30 h after irradiation compared to 6 h post-irradiation. Conversely, no significant changes in hypoxia were observed in tumors irradiated with 8.2 Gy of X-rays. To directly quantify hypoxia in the irradiated living tumors, we utilized dynamic contrast-enhanced magnetic resonance imaging (MRI) and diffusion-weighted imaging. These combined MRI techniques revealed that the non-hypoxic fraction in neon-irradiated tumors was significantly higher than that in X-irradiated tumors (69.53% vs. 47.67%). Simultaneously, the hypoxic fraction in neon-ion-irradiated tumors (2.77%) was lower than that in X-irradiated tumors (4.27%) and non-irradiated tumors (32.44%). These results support the notion that accelerated reoxygenation occurs more effectively with neon-ion beam irradiation compared to X-rays. These findings shed light on the physiological effects of neon-ion beams on tumors and their microenvironment, emphasizing the therapeutic advantage of using neon-ion charged particle beams to manipulate tumor reoxygenation.


Assuntos
Neoplasias , Camundongos , Animais , Neônio , Íons , Hipóxia , Microambiente Tumoral
3.
Ann Neurol ; 2023 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-37703428

RESUMO

OBJECTIVE: Increasing evidence suggests that reactive astrocytes are associated with Alzheimer's disease (AD). However, its underlying pathogenesis remains unknown. Given the role of astrocytes in energy metabolism, reactive astrocytes may contribute to altered brain energy metabolism. Astrocytes are primarily considered glycolytic cells, suggesting a preference for lactate production. This study aimed to examine alterations in astrocytic activities and their association with brain lactate levels in AD. METHODS: The study included 30 AD and 30 cognitively unimpaired participants. For AD participants, amyloid and tau depositions were confirmed by positron emission tomography using [11 C]PiB and [18 F]florzolotau, respectively. Myo-inositol, an astroglial marker, and lactate in the posterior cingulate cortex were quantified by magnetic resonance spectroscopy. These magnetic resonance spectroscopy metabolites were compared with plasma biomarkers, including glial fibrillary acidic protein as another astrocytic marker, and amyloid and tau positron emission tomography. RESULTS: Myo-inositol and lactate levels were higher in AD patients than in cognitively unimpaired participants (p < 0.05). Myo-inositol levels correlated with lactate levels (r = 0.272, p = 0.047). Myo-inositol and lactate levels were positively associated with the Clinical Dementia Rating sum-of-boxes scores (p < 0.05). Significant correlations were noted between myo-inositol levels and plasma glial fibrillary acidic protein, tau phosphorylated at threonine 181 levels, and amyloid and tau positron emission tomography accumulation in the posterior cingulate cortex (p < 0.05). INTERPRETATION: We found high myo-inositol levels accompanied by increased lactate levels in the posterior cingulate cortex in AD patients, indicating a link between reactive astrocytes and altered brain energy metabolism. Myo-inositol and plasma glial fibrillary acidic protein may reflect similar astrocytic changes as biomarkers of AD. ANN NEUROL 2023.

4.
J Magn Reson Imaging ; 57(3): 845-853, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-35838084

RESUMO

BACKGROUND: Visualization of aqueous humor flow in MR contrast images using gadolinium is challenging because of the delayed contrast effects associated with the blood-retinal and blood-aqueous humor barriers. However, oxygen-17 water (H2 17 O) might be used as an ocular contrast agent. PURPOSE: To observe the distribution of H2 17 O in the human eye, and its flow in and out of the anterior chamber, using dynamic T2-weighted MRI. STUDY TYPE: Prospective. POPULATION: Six ophthalmologically normal volunteers (20-37 years, six females). FIELD STRENGTH/SEQUENCE: A 3 T/dynamic T2-weighted MRI. ASSESSMENT: H2 17 O eye drops were administered to the right eye. Time-series images were created by subtracting the image before the eye drops from each of the images obtained after the eye drops. The normalized signal intensity of the right anterior chamber (nAC) was obtained by dividing the signal intensity of the right anterior chamber region by that of the left. The inflow and outflow constants of H2 17 O and H2 17 O concentration were calculated from the nAC. STATISTICAL TESTS: A paired t-test was used to compare the flow-related values and temporal changes in signal intensity. P-values < 0.05 were considered statistically significant. RESULTS: Significantly decreased signal intensity was observed in the right anterior chamber but not the right vitreous body (P = 0.39). The nAC signal intensity decreased significantly and then recovered. The inflow and outflow constants were 0.36-0.94 min-1 and 0.023-0.13 min-1 , respectively. The maximum H2 17 O concentration was 0.078%-0.24%. DATA CONCLUSION: H2 17 O were distributed in the anterior chamber. The H2 17 O inflow into the anterior chamber was significantly faster than that of the outflow. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY STAGE: 2.


Assuntos
Humor Aquoso , Movimentos da Água , Feminino , Humanos , Soluções Oftálmicas , Estudos Prospectivos , Imageamento por Ressonância Magnética/métodos
5.
Pediatr Res ; 91(1): 197-203, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-33674742

RESUMO

BACKGROUND: A very-low-birth-weight (VLBW) preterm infants is associated with an increased risk of impaired neurodevelopmental outcomes. In this study, we investigated how neonatal brain metabolite concentrations changed with postmenstrual age and examined the relationship between changes in concentration (slopes) and neurodevelopmental level at 3-4 years. METHODS: We retrospectively examined 108 VLBW preterm infants who had brain single-voxel magnetic resonance spectroscopy at 34-42 weeks' postmenstrual age. Neurodevelopment was assessed using a developmental test, and subjects were classified into four groups: developmental quotient <70, 70-84, 85-100, and >100. One-way analyses of covariance and multiple-comparison post hoc tests were used to compare slopes. RESULTS: We observed correlations between postmenstrual age and the concentrations of N-acetylaspartate and N-acetylaspartylglutamate (tNAA) (p < 0.001); creatine and phosphocreatine (p < 0.001); glutamate and glutamine (p < 0.001); and myo-inositol (p = 0.049) in the deep gray matter; and tNAA (p < 0.001) in the centrum semiovale. A significant interaction was noted among the tNAA slopes of the four groups in the deep gray matter (p = 0.022), and we found a significant difference between the <70 and 85-100 groups (post hoc, p = 0.024). CONCLUSIONS: In VLBW preterm infants, the slopes of tNAA concentrations (adjusted for postmenstrual age) were associated with lower developmental quotients at 3-4 years. IMPACT: In very-low-birth-weight preterm-born infants, a slower increase in tNAA brain concentration at term-equivalent age was associated with poorer developmental outcomes at 3-4 years. The increase in tNAA concentration in very-low-birth-weight infants was slower in poorer developmental outcomes, and changes in tNAA concentration appeared to be more critical than changes in tCho for predicting developmental delays. While tNAA/tCho ratios were previously used to examine the correlation with neurodevelopment at 1-2 years, we used brain metabolite concentrations.


Assuntos
Encéfalo/metabolismo , Recém-Nascido Prematuro , Feminino , Humanos , Recém-Nascido , Recém-Nascido de muito Baixo Peso , Espectroscopia de Ressonância Magnética/métodos , Masculino , Estudos Retrospectivos
6.
Hum Brain Mapp ; 42(7): 1969-1986, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33621388

RESUMO

Targeting specific brain regions of interest by the accurate positioning of optodes (emission and detection probes) on the scalp remains a challenge for functional near-infrared spectroscopy (fNIRS). Since fNIRS data does not provide any anatomical information on the brain cortex, establishing the scalp-cortex correlation (SCC) between emission-detection probe pairs on the scalp and the underlying brain regions in fNIRS measurements is extremely important. A conventional SCC is obtained by a geometrical point-to-point manner and ignores the effect of light scattering in the head tissue that occurs in actual fNIRS measurements. Here, we developed a sensitivity-based matching (SBM) method that incorporated the broad spatial sensitivity of the probe pair due to light scattering into the SCC for fNIRS. The SCC was analyzed between head surface fiducial points determined by the international 10-10 system and automated anatomical labeling brain regions for 45 subject-specific head models. The performance of the SBM method was compared with that of three conventional geometrical matching (GM) methods. We reveal that the light scattering and individual anatomical differences in the head affect the SCC, which indicates that the SBM method is compulsory to obtain the precise SCC. The SBM method enables us to evaluate the activity of cortical regions that are overlooked in the SCC obtained by conventional GM methods. Together, the SBM method could be a promising approach to guide fNIRS users in designing their probe arrangements and in explaining their measurement data.


Assuntos
Córtex Cerebral/diagnóstico por imagem , Córtex Cerebral/fisiologia , Neuroimagem Funcional/métodos , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Adulto , Humanos , Imageamento por Ressonância Magnética , Modelos Teóricos , Couro Cabeludo/diagnóstico por imagem
7.
Eur Radiol ; 29(11): 5999-6008, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31089847

RESUMO

PURPOSE: This study was conducted in order to assess the intra- and interoperator reproducibility of shear-wave speed (SWS) measurement on elasticity phantoms and healthy volunteers using ultrasound-based point shear-wave elastography. MATERIALS AND METHODS: This study was approved by the institutional review board. Two operators measured the SWS of five elasticity phantoms and seven organs (thyroid, lymph node, muscle, spleen, kidney, pancreas, and liver) of 30 healthy volunteers with 1.0-4.5 MHz convex (4C1) and 4.0-9.0 MHz linear (9L4) transducers. The phantom measurements were repeated ten times, while the volunteer measurements were performed five times each. Intra- and interoperator reproducibility was assessed. Interoperator reproducibility was also evaluated with the 95% Bland-Altman limits of agreement (LOA). RESULTS: In phantoms, all intraclass correlation coefficients (ICCs) were above 0.90 and the 95% LOA between the two operators were less than ± 18%. In volunteers, intraoperator ICCs were > 0.75 for all regions except the pancreas. Interoperator ICC was above 0.75 for the right lobe of the liver (depth 4 cm) and the kidney, but the 95% LOA was less than ± 25% only for the liver. CONCLUSION: Although excellent in phantoms, interoperator reproducibility was insufficient for all regions in the volunteers other than the right hepatic lobe at a depth of 4 cm. Clinicians should be aware of the 95% LOA when using SWS in patients. KEY POINTS: • Our phantom study indicated a high reproducibility for shear-wave speed (SWS) measurements with point shear-wave elastography (pSWE). • In volunteers, intraoperator reproducibility was generally high, but the interoperator reproducibility was not high enough except for the right hepatic lobe at 4 cm depth. • To evaluate interoperator reproducibility, the 95% limits of agreement (LOA) between operators should be considered in addition to the intraclass correlation coefficient (ICC).


Assuntos
Técnicas de Imagem por Elasticidade/normas , Adulto , Elasticidade , Feminino , Voluntários Saudáveis , Humanos , Rim/diagnóstico por imagem , Fígado/diagnóstico por imagem , Linfonodos/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Músculo Esquelético/diagnóstico por imagem , Variações Dependentes do Observador , Pâncreas/diagnóstico por imagem , Imagens de Fantasmas , Estudos Prospectivos , Reprodutibilidade dos Testes , Baço/diagnóstico por imagem , Glândula Tireoide/diagnóstico por imagem , Transdutores , Ultrassonografia , Adulto Jovem
8.
NMR Biomed ; 30(1)2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27859844

RESUMO

Gamma-aminobutyric acid (GABA) is the major inhibitory neurotransmitter in the brain, and plays a key role in brain development. However, the in vivo levels of brain GABA in early life are unknown. Using edited MRS, in vivo GABA can be detected as GABA+ signal with contamination of macromolecule signals. GABA+ is evaluated as the peak ratio of GABA+/reference compound, for which creatine (Cr) or water is typically used. However, the concentrations and T1 and T2 relaxation times of these references change during development. Thus, the peak ratio comparison between neonates and children may be inaccurate. The aim of this study was to measure in vivo neonatal brain GABA+ levels, and to investigate the dependency of GABA levels on brain region and age. The basal ganglia and cerebellum of 38 neonates and 12 children were measured using GABA-edited MRS. Two different approaches were used to obtain GABA+ levels: (i) multiplying the GABA/water ratio by the water concentration; and (ii) multiplying the GABA+/Cr by the Cr concentration. Neonates exhibited significantly lower GABA+ levels compared with children in both regions, regardless of the approach employed, consistent with previous ex vivo data. A similar finding of lower GABA+/water and GABA+/Cr in neonates compared with children was observed, except for GABA+/Cr in the cerebellum. This contrasting finding resulted from significantly lower Cr concentrations in the neonate cerebellum, which were approximately 52% of those of children. In conclusion, care should be taken to consider Cr concentrations when comparing GABA+/Cr levels between different-aged subjects.


Assuntos
Artefatos , Encéfalo/metabolismo , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética/métodos , Imagem Molecular/métodos , Ácido gama-Aminobutírico/metabolismo , Algoritmos , Feminino , Humanos , Recém-Nascido , Masculino , Neurotransmissores/metabolismo , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Distribuição Tecidual
9.
Eur Spine J ; 26(9): 2459-2466, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28623403

RESUMO

PURPOSE: The aim of this study was to assess the potential role of diffusion tensor imaging (DTI) as a predictor of surgical outcomes in patients with cervical compressive myelopathy (CCM). Surgical decompression is often recommended for symptomatic CCM. It is important to know the prognosis of surgical outcomes and to recommend appropriate timing for surgery. METHODS: We enrolled 26 patients with CCM who underwent surgery. The Japanese Orthopaedic Association (JOA) score for cervical myelopathy was evaluated before and 6 months after surgery. Surgical outcomes were regarded as good if there was a change in JOA score of three points or more, or the recovery rate of JOA score was 50% or more. The patients were examined using a 3.0 T magnetic resonance system before surgery. Measured diffusion parameters were fractional anisotropy (FA) and mean diffusivity (MD). The correlations between DTI parameters and surgical outcomes were analyzed. RESULTS: Both change and recovery rate of JOA score moderately correlated with FA. Furthermore, the area under the receiver-operator characteristic curve based on FA for prognostic precision of surgical outcomes indicates that FA is a good predictive factor. The cut-off values of FA for predicting good surgical outcomes evaluated by change and recovery rate of JOA score were 0.65 and 0.57, respectively. Neither change nor recovery rate of JOA score correlated with MD. CONCLUSIONS: FA in spinal cord DTI can moderately predict surgical outcomes. DTI can serve as a supplementary tool for decision-making to guide surgical intervention in patients with CCM.


Assuntos
Vértebras Cervicais/cirurgia , Compressão da Medula Espinal/diagnóstico por imagem , Compressão da Medula Espinal/cirurgia , Adulto , Idoso , Anisotropia , Vértebras Cervicais/diagnóstico por imagem , Tomada de Decisão Clínica/métodos , Descompressão Cirúrgica , Imagem de Tensor de Difusão/métodos , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Ossificação do Ligamento Longitudinal Posterior/diagnóstico por imagem , Ossificação do Ligamento Longitudinal Posterior/cirurgia , Prognóstico , Curva ROC , Índice de Gravidade de Doença , Resultado do Tratamento
10.
Acta Neuropsychiatr ; 29(3): 153-163, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27620171

RESUMO

OBJECTIVE: To investigate the relationship between the severities of symptom dimensions in obsessive-compulsive disorder (OCD) and white matter alterations. METHODS: We applied tract-based spatial statistics for diffusion tensor imaging (DTI) acquired by 3T magnetic resonance imaging. First, we compared fractional anisotropy (FA) between 20 OCD patients and 30 healthy controls (HC). Then, applying whole brain analysis, we searched the brain regions showing correlations between the severities of symptom dimensions assessed by Obsessive-Compulsive Inventory-Revised and FA in all participants. Finally, we calculated the correlations between the six symptom dimensions and multiple DTI measures [FA, axial diffusivity (AD), radial diffusivity (RD), mean diffusivity (MD)] in a region-of-interest (ROI) analysis and explored the differences between OCD patients and HC. RESULTS: There were no between-group differences in FA or brain region correlations between the severities of symptom dimensions and FA in any of the participants. ROI analysis revealed negative correlations between checking severity and left inferior frontal gyrus white matter and left middle temporal gyrus white matter and a positive correlation between ordering severity and right precuneus in FA in OCD compared with HC. We also found negative correlations between ordering severity and right precuneus in RD, between obsessing severities and right supramarginal gyrus in AD and MD, and between hoarding severity and right insular gyrus in AD. CONCLUSION: Our study supported the hypothesis that the severities of respective symptom dimensions are associated with different patterns of white matter alterations.


Assuntos
Encéfalo/diagnóstico por imagem , Imagem de Tensor de Difusão/métodos , Transtorno Obsessivo-Compulsivo/diagnóstico , Córtex Pré-Frontal/diagnóstico por imagem , Substância Branca/patologia , Adolescente , Adulto , Anisotropia , Encéfalo/patologia , Imagem de Difusão por Ressonância Magnética/métodos , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Japão/epidemiologia , Masculino , Pessoa de Meia-Idade , Transtorno Obsessivo-Compulsivo/tratamento farmacológico , Transtorno Obsessivo-Compulsivo/patologia , Córtex Pré-Frontal/patologia , Índice de Gravidade de Doença , Adulto Jovem
11.
Eur Radiol ; 26(8): 2559-66, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26443602

RESUMO

OBJECTIVES: A new method that can estimate diffusional kurtosis image (DKI), estimated DKI (eDKI), parallel and perpendicular to neuronal fibres from greatly limited image data was designed to enable quick and practical assessment of DKI in clinics. The purpose of this study was to discuss the potential of this method for clinical use. METHODS: Fourteen healthy volunteers were examined with a 3-Tesla MRI. The diffusion-weighting parameters included five different b-values (0, 500, 1,500, 2,000 and 2,500 s/mm(2)) with 64 different encoding directions for each of the b-values. K values were calculated by both conventional DKI (convDKI) and eDKI from these complete data, and also from the data that the encoding directions were abstracted to 32, 21, 15, 12 and 6. Error-pixel ratio and the root mean square error (RMSE) compared with the standard were compared between the methods (Wilcoxon signed-rank test: P < 0.05 was considered significant). RESULTS: Error-pixel ratio was smaller in eDKI than in convDKI and the difference was significant. In addition, RMSE was significantly smaller in eDKI than in convDKI, or otherwise the differences were not significant when they were obtained from the same data set. CONCLUSION: eDKI might be useful for assessing DKI in clinical settings. KEY POINTS: • A method to practically estimate axial/radial DKI from limited data was developed. • The high robustness of the proposed method can greatly improve map images. • The accuracy of the proposed method was high. • Axial/radial K maps can be calculated from limited diffusion-encoding directions. • The proposed method might be useful for assessing DKI in clinical settings.


Assuntos
Encéfalo/diagnóstico por imagem , Imagem de Tensor de Difusão/métodos , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Adulto , Feminino , Voluntários Saudáveis , Humanos , Masculino , Curva ROC , Adulto Jovem
12.
Eur Radiol ; 25(6): 1701-7, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25577520

RESUMO

OBJECTIVES: To compare the significance of the two-compartment model, considering diffusional anisotropy with conventional diffusion analyzing methods regarding the detection of occult changes in normal-appearing white matter (NAWM) of multiple sclerosis (MS). METHODS: Diffusion-weighted images (nine b-values with six directions) were acquired from 12 healthy female volunteers (22-52 years old, median 33 years) and 13 female MS patients (24-48 years old, median 37 years). Diffusion parameters based on the two-compartment model of water diffusion considering diffusional anisotropy was calculated by a proposed method. Other parameters including diffusion tensor imaging and conventional apparent diffusion coefficient (ADC) were also obtained. They were compared statistically between the control and MS groups. RESULTS: Diffusion of the slow diffusion compartment in the radial direction of neuron fibers was elevated in MS patients (0.121 × 10(-3) mm2/s) in comparison to control (0.100 × 10(-3) mm(2)/s), the difference being significant (P = 0.001). The difference between the groups was not significant in other comparisons, including conventional ADC and fractional anisotropy (FA) of diffusion tensor imaging. CONCLUSION: The proposed method was applicable to clinically acceptable small data. The parameters obtained by this method improved the detectability of occult changes in NAWM compared to the conventional methods. KEY POINTS: • Water diffusion was compared between the controls and multiple sclerosis patients. • A two-compartment model, considering diffusional anisotropy was selected for water diffusion analysis. • Axial and radial diffusion of fast and slow diffusion components were evaluated. • A new method was developed to obtain the metrics stably. • The metrics indicated high detectability of slight differences between the groups.


Assuntos
Esclerose Múltipla/patologia , Substância Branca/patologia , Adulto , Anisotropia , Água Corporal/fisiologia , Estudos de Casos e Controles , Difusão , Imagem de Difusão por Ressonância Magnética/métodos , Imagem de Tensor de Difusão/métodos , Feminino , Humanos , Pessoa de Meia-Idade , Neurônios/patologia
13.
Neuroimage ; 98: 258-65, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24780698

RESUMO

Diffusion-weighted (DW) functional magnetic resonance imaging (fMRI) signal changes have been noted as a promising marker of neural activity. Although there is no agreement on the signal origin, the blood oxygen level dependent (BOLD) effect has figured as one of the most likely sources. In order to investigate possible BOLD and non-BOLD contributions to the signal, DW fMRI was performed on normal volunteers using a sequence with two echo-planar acquisitions after pulsed-gradient spin-echo. Along with the changes to the signal amplitude (ΔS/S) measured at both echo-times, this sequence allowed changes to the transverse relaxation rate (ΔR2) to be estimated for multiple b-values during hypercapnia (HC) and visual stimulation (VS). ΔS/S and ΔR2 observed during HC were relatively insensitive to increasing b-value. On the other hand, ΔS/S demonstrated a clear dependence on b-value at both echo-times for VS. In addition, ΔR2 during the latter half of VS was significantly more negative at b=1400s/mm(2) than for the time-courses at lower b-value, but ΔR2 during the post-stimulus undershoot was independent of b-value. The results have been discussed in terms of two models: the standard intravascular-extravascular model for fMRI and a three-compartment model (one intra- and two extravascular compartments). Within these interpretations the results suggest that the majority of the response is linked to changes in transverse relaxation, but possible contributions from other sources may not be ruled out.


Assuntos
Mapeamento Encefálico/métodos , Imagem de Difusão por Ressonância Magnética/métodos , Encéfalo/metabolismo , Encéfalo/fisiologia , Humanos , Hipercapnia/metabolismo , Modelos Neurológicos , Estimulação Luminosa
14.
J Magn Reson Imaging ; 40(6): 1481-6, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24259448

RESUMO

PURPOSE: To evaluate the effect of the static magnetic field of magnetic resonance (MR) scanners on keepers (ie, ferromagnetic stainless steel plate adhered to the abutment tooth of dental magnetic attachments). MATERIALS AND METHODS: Magnetically induced displacement force and torque on keepers were measured using 1.5 Tesla (T) and 3.0 T MR scanners and a method outlined by American Society for Testing and Materials (ASTM). Changes in magnetic flux density before and after exposure to scanner static magnetic field were examined. RESULTS: The maximum magnetically induced displacement forces were calculated to be 10.3 × 10(-2) N at 1.5 T and 13.9 × 10(-2) N at 3.0 T on the cover surface. The maximum torques exerted on the keeper (4 mm in diameter) were 0.83 N × 4 mm at 1.5 T and 0.85 N × 4 mm at 3.0 T. These forces were considerably higher than the gravitational force (7.7 × 10(-4) N) of the keeper but considerably lower than the keeper-root cap proper adhesive force. The keepers' magnetic flux density remained less than that of the Earth. CONCLUSION: Magnetically induced displacement force and torque on the keeper in the MR scanner do not influence the keeper-root cap proper adhesive force.


Assuntos
Ligas Dentárias/efeitos da radiação , Retenção em Prótese Dentária/instrumentação , Análise do Estresse Dentário/métodos , Campos Magnéticos , Imageamento por Ressonância Magnética/instrumentação , Imãs , Desenho de Equipamento , Análise de Falha de Equipamento , Movimento (Física) , Estresse Mecânico , Torque
15.
J Shoulder Elbow Surg ; 23(5): 636-41, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24745313

RESUMO

BACKGROUND: Although fatty degeneration of the rotator cuff muscles has been reported to affect the outcomes of rotator cuff repairs, only a few studies have attempted to quantitatively evaluate this degeneration. T2 mapping is a quantitative magnetic resonance imaging technique that potentially evaluates the concentration of fat in muscles. The purpose of this study was to investigate fatty degeneration of the rotator cuff muscles by using T2 mapping, as well as to evaluate the reliability of T2 measurement. METHODS: We obtained magnetic resonance images including T2 mapping from 184 shoulders (180 patients; 110 male patients [112 shoulders] and 70 female patients [72 shoulders]; mean age, 62 years [range, 16-84 years]). Eighty-three shoulders had no rotator cuff tear (group A), whereas 101 shoulders had tears, of which 62 were incomplete to medium (group B) and 39 were large to massive (group C). T2 values of the supraspinatus and infraspinatus muscles were measured and compared among groups. Intraobserver and interobserver variabilities also were examined. RESULTS: The mean T2 values of the supraspinatus in groups A, B, and C were 36.3 ± 4.7 milliseconds, 44.2 ± 11.3 milliseconds, and 57.0 ± 18.8 milliseconds, respectively. The mean T2 values of the infraspinatus in groups A, B, and C were 36.1 ± 5.1 milliseconds, 40.0 ± 11.1 milliseconds, and 51.9 ± 18.2 milliseconds, respectively. The T2 value significantly increased with the extent of the tear in both muscles. Both intraobserver and interobserver variabilities were more than 0.99. CONCLUSION: T2 mapping can be a reliable tool to quantify fatty degeneration of the rotator cuff muscles.


Assuntos
Tecido Adiposo/patologia , Imageamento por Ressonância Magnética , Músculo Esquelético/patologia , Manguito Rotador/patologia , Traumatismos dos Tendões/diagnóstico , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Lesões do Manguito Rotador , Traumatismos dos Tendões/patologia , Adulto Jovem
16.
Radiol Phys Technol ; 17(1): 60-70, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37874462

RESUMO

The purpose of this study is to evaluate the RF field responses of partial-ring RF-shielded oval-shaped positron emission tomography (PET) inserts that are used in combination with an MRI body RF coil. Partial-ring PET insert is particularly suitable for interventional investigation (e.g., trimodal PET/MRI/ultrasound imaging) and intraoperative (e.g., robotic surgery) PET/MRI studies. In this study, we used electrically floating Faraday RF shield cages to construct different partial-ring configurations of oval and cylindrical PET inserts and performed experiments on the RF field, spin echo and gradient echo images for a homogeneous phantom in a 3 T clinical MRI system. For each geometry, partial-ring configurations were studied by removing an opposing pair or a single shield cage from different positions of the PET ring. Compared to the MRI-only case, reduction in mean RF homogeneity, flip angle, and SNR for the detector opening in the first and third quadrants was approximately 13%, 15%, and 43%, respectively, whereas the values were 8%, 23%, and 48%, respectively, for the detector openings in the second and fourth quadrants. The RF field distribution also varied for different partial-ring configurations. It can be concluded that the field penetration was high for the detector openings in the first and third quadrants of both the inserts.


Assuntos
Imageamento por Ressonância Magnética , Tomografia por Emissão de Pósitrons , Desenho de Equipamento , Tomografia por Emissão de Pósitrons/métodos , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Ondas de Rádio
17.
Magn Reson Med Sci ; 2024 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-38346767

RESUMO

PURPOSE: The purpose of this study was to do a feasibility study on a microstrip transmission line (MS) RF coil for a positron emission tomography (PET) insert in a 7 Tesla human MRI system. The proposed MS coil integrated the RF shield of the PET detector as the ground conductor of the coil. We called the integrated module "MS PET coil." METHODS: A single-channel MS PET coil was developed with an integrated RF-shielded PET detector module. For comparison, we also studied a conventional MS coil with a single-layer ground conductor. A lutetium fine silicate (LFS) scintillation crystal block (14 × 14 × 4-layer) with a silicon photomultiplier (Hamamatsu Photonics K.K., Shizuoka, Japan) and a front-end readout circuit board were mounted inside the shield cage of the MS PET coil. The MS PET coil was studied with and without PET detectors. All three coil configurations were studied with a homogeneous phantom in a 7T MRI system (Siemens Healthineers, Erlangen, Germany). PET data measurements were conducted using a Cesium-137 radiation point source. RESULTS: The MR images were similar for the MS coil and the empty MS PET coil, as well as for the cases of MS PET coil with and without PET measurements. Compared to the empty MS PET coil (without PET detector and cable RF shield), decreases in SNR, increases in image noise and RF power, and a slight decrease in resonance frequency were seen for the case of the MS PET coil with the detector and cable shield. Differences in the PET energy histograms or in the crystal identification maps with and without MRI measurements were negligible. CONCLUSIONS: Both the MRI and PET performances of the MS PET coil showed responses that matched the MS coil responses. The performance variations of MRI data with and without PET measurement and PET data with and without MR imaging were negligible.

18.
Ultrasound Med Biol ; 50(4): 592-599, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38238201

RESUMO

OBJECTIVE: Hepatic fibrosis has recently been evaluated using ultrasonography or magnetic resonance elastography. Although the shear wave velocity (SWV) obtained using point shear wave elastography (pSWE) provides a valuable measure of fibrosis, underlying steatosis may affect its measurement. METHODS: Using hepatic fibrosis samples, this study evaluated the effect of steatosis on the shear wave velocity of pSWE (Vs) and viscoelastic properties (assessed by dynamic mechanical analysis) of rat liver. Fifty rats with various grades of steatosis and fibrosis underwent open abdominal in vivo Vs measurements using a commercial ultrasound scanner. The mechanical properties of hepatic tissue were also characterized under ex vivo conditions using dynamic mechanical analysis and the Zener model of viscoelasticity. RESULTS: Fibrosis and steatosis progression influenced Vs and elasticity. The SWV computed using the Zener model and Vs showed a substantial correlation (r > 0.8). Fibrosis progression increased SWV. Steatosis was also related to SWV. Steatosis progression obscured the SWV change associated with fibrosis progression. CONCLUSION: We conclude that steatosis progression affects the evaluation of fibrosis progression. This finding could aid discrimination of non-alcoholic steatohepatitis from non-alcoholic fatty liver disease using SWV.


Assuntos
Técnicas de Imagem por Elasticidade , Hepatopatia Gordurosa não Alcoólica , Ratos , Animais , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/complicações , Fígado/diagnóstico por imagem , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Hepatopatia Gordurosa não Alcoólica/complicações , Fibrose
19.
Jpn J Radiol ; 42(4): 382-390, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38110835

RESUMO

PURPOSE: To perform an MRI compatibility study of an RF field-penetrable oval-shaped PET insert that implements an MRI built-in body RF coil both as a transmitter and a receiver. METHODS: Twelve electrically floating RF shielded PET detector modules were used to construct the prototype oval PET insert with a major axis of 440 mm, a minor axis of 350 mm, and an axial length of 225 mm. The electric floating of the PET detector modules was accomplished by isolating the cable shield from the detector shield using plastic tape. Studies were conducted on the transmit (B1) RF field, the image signal-to-noise ratio (SNR), and the RF pulse amplitude for a homogeneous cylindrical (diameter: 160 mm and length: 260 mm) phantom (NaCl + NiSO4 solution) in a 3 T clinical MRI system (Verio, Siemens, Erlangen, Germany). RESULTS: The B1 maps for the oval insert were similar to the MRI-only field responses. Compared to the MRI-only values, SNR reductions of 51%, 45%, and 59% were seen, respectively, for the spin echo (SE), gradient echo (GE), and echo planar (EPI) images for the case of oval PET insert. Moreover, the required RF pulse amplitudes for the SE, GE, and EPI sequences were, respectively, 1.93, 1.85, and 1.36 times larger. However, a 30% reduction in the average RF reception sensitivity was observed for the oval insert. CONCLUSIONS: The prototype floating PET insert was a safety concern for the clinical MRI system, and this compatibility study provided clearance for developing a large body size floating PET insert for the existing MRI system. Because of the RF shield of the insert, relatively large RF powers compared to the MRI-only case were required. Because of this and also due to low RF sensitivity of the body coil, the SNRs reduced largely.


Assuntos
Imageamento por Ressonância Magnética , Tomografia por Emissão de Pósitrons , Humanos , Tomografia por Emissão de Pósitrons/métodos , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Ondas de Rádio , Razão Sinal-Ruído
20.
Int J Part Ther ; 12: 100018, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-39022118

RESUMO

Purpose: This study aimed to quantify the changes in intratumoral blood flow after carbon-ion radiation therapy (CIRT) for early-stage breast cancer and analyze their clinical significance. Patients and Methods: We included 38 patients with early-stage breast cancer who underwent CIRT. Dynamic imaging was performed using a 3T superconducting magnetic resonance scanner to quantify the washin index (idx), which reflects contrast uptake, and washout idx, which reflects the rate of contrast washout from tumor tissue. The changes in the apparent diffusion coefficient, washin idx, and washout idx were examined before CIRT and at 1 and 3 months after treatment. Clinical factors and imaging features were examined using univariate and receiver operating characteristic curve analyses to identify factors predicting clinical complete response (cCR). Results: The median observation period after CIRT was 51 (range: 12-122) months. During the observation period, 31 of the 38 patients achieved cCR, and 22 achieved cCR within 12 months. Tumor size (P < .001), washin idx (P = .043), and washout idx (P < .001) decreased significantly 1-month after CIRT. In contrast, the apparent diffusion coefficient values (P < .001) increased significantly 1-month after CIRT. Univariate analysis suggested that the washin idx after 1 and 3 months of CIRT was associated with cCR by 12 months post-CIRT (P = .028 and .021, respectively). No other parameters were associated with cCR by 12 months post-CIRT. Furthermore, receiver operating characteristic curve analyses showed that the area under the curve values of washin idx after 1 and 3 months of CIRT was 0.78 (specificity 75%, sensitivity 80%) and 0.73 (specificity 75%, sensitivity 71%), respectively. Conclusion: Tumor changes can be quantified early after CIRT using contrast-enhanced magnetic resonance imaging in patients with breast cancer. Washin idx values 1 and 3 months after CIRT were associated with cCR within 12 months post-CIRT.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA