Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Abdom Imaging ; 40(7): 2323-30, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25985968

RESUMO

PURPOSE: To perform image quality comparison between accelerated multiband diffusion acquisition (mb2-DWI) and conventional diffusion acquisition (c-DWI) in patients undergoing clinically indicated liver MRI. METHODS: In this prospective study 22 consecutive patients undergoing clinically indicated liver MRI on a 3-T scanner equipped to perform multiband diffusion-weighed imaging (mb-DWI) were included. DWI was performed with single-shot spin-echo echo-planar technique with fat-suppression in free breathing with matching parameters when possible using c-DWI, mb-DWI, and multiband DWI with a twofold acceleration (mb2-DWI). These diffusion sequences were compared with respect to various parameters of image quality, lesion detectability, and liver ADC measurements. RESULTS: Accelerated mb2-DWI was 40.9% faster than c-DWI (88 vs. 149 s). Various image quality parameter scores were similar or higher on mb2-DWI when compared to c-DWI. The overall image quality score (averaged over the three readers) was significantly higher for mb-2 compared to c-DWI for b = 0 s/mm(2) (3.48 ± 0.52 vs. 3.21 ± 0.54; p = 0.001) and for b = 800 s/mm(2) (3.24 ± 0.76 vs. 3.06 ± 0.86; p = 0.010). Total of 25 hepatic lesions were visible on mb2-DWI and c-DWI, with identical lesion detectability. There was no significant difference in liver ADC between mb2-DWI and c-DWI (p = 0.12). Bland-Altman plot demonstrates lower mean liver ADC with mb2-DWI compared to c-DWI (by 0.043 × 10(-3) mm(2)/s or 3.7% of the average ADC). CONCLUSION: Multiband technique can be used to increase acquisition speed nearly twofold for free-breathing DWI of the liver with similar or improved overall image quality and similar lesion detectability compared to conventional DWI.


Assuntos
Imagem de Difusão por Ressonância Magnética , Hepatopatias/patologia , Fígado/patologia , Respiração , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Estudos Prospectivos , Reprodutibilidade dos Testes
2.
Abdom Imaging ; 40(2): 327-32, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25106502

RESUMO

PURPOSE: To explore associations of whole-lesion histogram diffusion metrics with pathologic findings and subsequent metastatic disease in bladder cancer patients undergoing radical cystectomy. METHODS: Twenty-three bladder cancer patients (21M, 2F; mean 70 ± 11 years) underwent MRI before cystectomy. A volume-of-interest was placed on all slices on the ADC map encompassing each lesion. Whole-lesion mean, kurtosis, and skewness of ADC were calculated and compared with T stage and pelvic nodal status at cystectomy and with subsequent metastasis in 20/25 patients with available follow-up. RESULTS: At cystectomy, 39 % (9/23) were stage T2, 61 % (14/23) ≥T3, and 28 % (5/23) exhibited positive nodes; 35 % (7/20) developed later metastases. Mean ADC was significantly lower in stage ≥T3 than in lower stage tumors (1.20 ± 0.36 × 10(-3) vs. 1.55 ± 0.36 × 10(-3) mm(2)/s; p = 0.044), but showed no association with nodal or metastatic disease (p = 0.362-0.709). Kurtosis was significantly lower in tumors with, compared to without, nodal disease (-0.05 ± 0.29 vs. 0.91 ± 1.16; p = 0.037), and showed a non-significant decrease in tumors with, compared to without, later metastases (0.23 ± 0.63 vs. 0.83 ± 0.89; p = 0.088). Kurtosis was not associated with T stage (p = 0.811), and skew was not associated with any outcome (p = 0.516-0.643). Mean ADC achieved highest AUC for identification of stage ≥T3 (AUC = 0.754 vs. 0.516-0.643 for other metrics). Kurtosis achieved highest AUC for nodal disease (AUC = 0.811 vs. 0.522-0.556 for other metrics) and metastases (AUC = 0.736 vs. 0.516-0.626 for other metrics). Only difference in AUC between skewness and kurtosis for nodal disease was significant (p = 0.031). CONCLUSION: While requiring larger studies, kurtosis has potential to complement mean ADC in bladder cancer prognosis using whole-lesion histogram analysis.


Assuntos
Imagem de Difusão por Ressonância Magnética , Neoplasias da Bexiga Urinária/patologia , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Invasividade Neoplásica , Reprodutibilidade dos Testes , Estudos Retrospectivos
3.
J Comput Assist Tomogr ; 35(3): 382-6, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21586935

RESUMO

BACKGROUND: Cardiac magnetic resonance imaging (CMRI) is an important tool to assess cardiac function. However, one of the limitations of CMRI is the need for frequent breath-holding (BH) steps. This may be inconvenient to some patients and limit the use of this modality in patients unable to cooperate because of cognitive reasons or physically incapable of performing the required BH steps. The purpose of this study is to overcome the intrinsic timing and computation limitations of dual-navigator cine imaging and demonstrate the feasibility of free-breathing (FB) cine cardiac left ventricular function with a single-respiratory-navigator gating at 3 T. RESULTS: Eight participants underwent cine CMRI with both the conventional 2-dimensional cine BH and FB navigator-gated techniques. Scan parameters were identical, except in the FB technique, in which a respiratory navigator and only 2 signal averages were used. Images were scored for quality. Left ventricular end-systolic volume and end-diastolic volume were calculated. The differences in the end-systolic volume and end-diastolic volume assessed by the BH and FB were not statistically significant with P = 0.9 and 0.2, respectively. There was a good agreement between LV volumes with the limits of agreement (± 2 SD = ± 22.36 mL). Image quality score was not significantly different (P = 0.76). CONCLUSIONS: Free-breathing cine imaging utilizing a single-respiratory-navigator gating technique is comparable to conventional BH technique in both qualitative and quantitative imaging measures. Therefore, the FB cine technique can be used as an alternative for children and patients who are unable to hold their breath.


Assuntos
Doenças Cardiovasculares/diagnóstico , Imagem Cinética por Ressonância Magnética/métodos , Estudos de Viabilidade , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Respiração
4.
J Am Coll Radiol ; 14(5): 609-614, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28017529

RESUMO

PURPOSE: The aim of this study was to evaluate patient satisfaction scores for interventional radiologists (IRs) across the United States using a leading physician ratings website. METHODS: The physician ratings website Healthgrades was manually queried for all 2,774 Medicare-participating self-designated IRs. All patient-reviewed IRs for whom the primary "likelihood of recommending to family and friends" field was scored were included, resulting in 781 included IRs. Physician characteristics were extracted from Medicare data sets. All available patient satisfaction scores (1 [poor] to 5 [excellent]: likelihood to recommend, ease of scheduling, office environment, staff friendliness, trust in physician's decisions, how well physician explains condition, how well physician listens and answers questions, whether physician spends appropriate time with patients) and wait times were extracted from Healthgrades. Associations among measures were explored. RESULTS: IRs' mean likelihood-to-recommend score was 4.3 ± 1.2 (median, 5.0; 64.5% received a score of 5; 10.5% received scores < 3). Mean scores ranged from 4.4 to 4.5 for office-related factors and from 4.3 to 4.5 for physician-related factors. Likelihood-to-recommend scores showed substantial correlations with office-related factors (r = 0.738 to 0.780) and physician-related factors (r = 0.918 to 0.946). Likelihood to recommend was significantly higher for IRs with shorter wait times (P < .001) but was not associated with physician gender or geographic region (P = 0.370-0.791), nor was there any correlation with physician age, years since graduation, or group practice size (r = -0.089 to 0.096). CONCLUSIONS: Satisfaction scores on a leading physician ratings website generally range from very good to excellent for US IRs. Most patients leaving reviews are likely to recommend their own IRs to friends or family members. The likelihood to recommend is strongly associated with differences in wait times.


Assuntos
Satisfação do Paciente , Radiologistas/classificação , Radiologia Intervencionista , Pesquisas sobre Atenção à Saúde , Humanos , Medicare/estatística & dados numéricos , Estados Unidos
5.
Case Rep Obstet Gynecol ; 2016: 9835412, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27066283

RESUMO

Background. Since its introduction in 1996, uterine fibroid embolization (UFE) has become standard medical practice in the management of symptomatic uterine fibroids. An extremely rare complication, pyomyoma, has been reported only 5 times previously in the literature following UFE. Case. A 37-year-old woman underwent UFE for symptomatic leiomyomas of the uterus. Signs and symptoms of uterine infection ensued, beginning at 6 days following the procedure. Recurrent fevers and increasing leukocytosis despite the intravenous administration of appropriate antibiotics eventually necessitated surgical intervention on postprocedure day #18. Conclusion. An extremely rare complication of UFE is herein presented, pyomyoma, with a review of other reported cases. Commonalities are sought among these few reported cases with the hope of increasing diagnostic acumen in the detection of this disease.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA