Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Circ Heart Fail ; 17(2): e010973, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38299348

RESUMO

BACKGROUND: Clinical evaluation of central venous pressure is difficult, depends on experience, and is often inaccurate in patients with chronic advanced heart failure. We assessed the ultrasound-assessed internal jugular vein (JV) distensibility by ultrasound as a noninvasive tool to identify patients with normal right atrial pressure (RAP ≤7 mm Hg) in this population. METHODS: We measured JV distensibility as the Valsalva-to-rest ratio of the vein diameter in a calibration cohort (N=100) and a validation cohort (N=101) of consecutive patients with chronic heart failure with reduced ejection fraction who underwent pulmonary artery catheterization for advanced heart failure therapies workup. RESULTS: A JV distensibility threshold of 1.6 was identified as the most accurate to discriminate between patients with RAP ≤7 versus >7 mm Hg (area under the receiver operating characteristic curve, 0.74 [95% CI, 0.64-0.84]) and confirmed in the validation cohort (receiver operating characteristic, 0.82 [95% CI, 0.73-0.92]). A JV distensibility ratio >1.6 had predictive positive values of 0.86 and 0.94, respectively, to identify patients with RAP ≤7 mm Hg in the calibration and validation cohorts. Compared with patients from the calibration cohort with a high JV distensibility ratio (>1.6; n=42; median RAP, 4 mm Hg; pulmonary capillary wedge pressure, 11 mm Hg), those with a low JV distensibility ratio (≤1.6; n=58; median RAP, 8 mm Hg; pulmonary capillary wedge pressure, 22 mm Hg; P<0.0001 for both) were more likely to die or undergo a left ventricular assist device implant or heart transplantation (event rate at 2 years: 42.7% versus 18.2%; log-rank P=0.034). CONCLUSIONS: Ultrasound-assessed JV distensibility identifies patients with chronic advanced heart failure with normal RAP and better outcomes. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03874312.


Assuntos
Insuficiência Cardíaca , Humanos , Pressão Atrial , Cateterismo Cardíaco , Cateterismo de Swan-Ganz , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/terapia , Veias Jugulares/diagnóstico por imagem , Pressão Propulsora Pulmonar , Volume Sistólico
2.
J Clin Med ; 13(2)2024 Jan 22.
Artigo em Inglês | MEDLINE | ID: mdl-38276125

RESUMO

Catheter-based revascularization procedures were developed as an alternative to systemic thrombolysis for patients with intermediate-high- and high-risk pulmonary embolisms. USAT IH-PE is a retrospective and prospective multicenter registry of such patients treated with ultrasound-facilitated, catheter-directed thrombolysis, whose preliminary results are presented in this study. The primary endpoint was the incidence of pulmonary hypertension (PH) at follow-up. Secondary endpoints were short- and mid-term changes in the echocardiographic parameters of right ventricle (RV) function, in-hospital and all-cause mortality, and procedure-related bleeding events. Between March 2018 and July 2023, 102 patients were included. The majority were at intermediate-high-risk PE (86%), were mostly female (57%), and had a mean age of 63.7 ± 14.5 years, and 28.4% had active cancer. Echocardiographic follow-up was available for 70 patients, and in only one, the diagnosis of PH was confirmed by right heart catheterization, resulting in an incidence of 1.43% (CI 95%, 0.036-7.7). RV echocardiographic parameters improved both at 24 h and at follow-up. In-hospital mortality was 3.9% (CI 95%, 1.08-9.74), while all-cause mortality was 11% (CI 95%, 5.4-19.2). Only 12% had bleeding complications, of whom 4.9% were BARC ≥ 3. Preliminary results from the USAT IH-PE registry showed a low incidence of PH, improvement in RV function, and a safe profile.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA