RESUMO
AIMS: The magnitude of upper abdominal organ motion in children may be overestimated by current planning target volumes (PTV). A four-dimensional computed tomography (4DCT) - derived internal target volume (ITV) is frequently used in adult radiotherapy to take respiratory-related organ motion into account. In this study, the dosimetric consequences for target coverage and organs at risk from the use of an ITV approach compared to standard PTV margins in children with high-risk neuroblastoma were investigated. MATERIALS AND METHODS: 14 patients, median age 4.1 years, range 1.5 - 18.9 years, (9 midline targets, 5 lateralised) each had two dual arc volumetric modulated arc therapy (VMAT) plans (14 ×1.5 Gy) generated. One used an ITV-approach; motion information derived from 4DCT (PTV_itv) with a 5mm ITV to PTV expansion, and the other a PTV margin of 10mm from CTV to PTV (PTV_standard). Differences in absolute PTV volume and organ at risk doses are described. RESULTS: The ITV approach resulted in a highly significant reduction in PTV size of 38% (p<0.0001). For midline targets, an ITV approach resulted in a small but statistically significant reduction in combined mean kidney dose of 0.8Gy, p 0.01. Mean heart and lung dose were reduced by an average of 1 Gy with an ITV approach. Non-PTV integral dose from 30.4 Gy L to 27.8 Gy L using an ITV approach. CONCLUSION: An ITV-approach to respiratory related organ motion management in children can significantly reduce absolute PTV volumes, maintain target coverage and reduce dose delivered to normal tissue in proximity to the target. This is an essential step to maximising the benefits of highly conformal radiotherapy techniques including VMAT for this patient group, and in the future with Proton Therapy.
RESUMO
Purpose: A scoping literature review was conducted to identify gastrointestinal (GI) factors most likely to influence prostate motion during radiotherapy. We proffer that patient specific measurement of these GI factors could predict motion uncertainty during radiotherapy, facilitating personalised care by optimising treatment technique e.g., daily adaption or via bespoke patient pre-habilitation and preparation. Methods: The scoping review was undertaken as per JBI guidelines. Searches were conducted across four databases: Ovid Medline®, EMBASE, CINAHL and EBSCO discovery. Articles written in English from 2010-present were included. Those pertaining to paediatrics, biological women exclusively, infectious and post-treatment GI morbidity and diet were excluded.Common GI factors impacting men were identified and related symptoms, incidence and measurement tools examined. Prevalence among persons with prostate cancer was explored and suitable assessment tools discussed. Results: A preliminary search identified four prominent GI-factors: mental health, co-morbidity and medication, physical activity, and pelvic floor disorder. The scoping search found 3644 articles; 1646 were removed as duplicates. A further 1249 were excluded after title and abstract screening, 162 remained subsequent to full text review: 42 mental health, 53 co-morbidity and medication, 39 physical activity and 28 pelvic floor disorder.Six GI factors prevalent in the prostate cancer population and estimated most likely to influence prostate motion were identified: depression, anxiety, diabetes, obesity, low physical activity, and pelvic floor disorder. Reliable, quick, and easy to use tools are available to quantify these factors. Conclusion: A comprehensive GI factor assessment package suitable to implement into the radiotherapy clinic has been created. Unveiling these GI factors upfront will guide improved personalisation of radiotherapy.
RESUMO
Introduction: Distended rectums on pre-radiotherapy scans are historically associated with poorer outcomes in patients treated with two-dimensional IGRT. Subsequently, strict rectal tolerances and preparation regimes were implemented. Contemporary IGRT, daily online registration to the prostate, corrects interfraction motion but intrafraction motion remains. We re-examine the need for rectal management strategies when using contemporary IGRT by quantifying rectal volume and its effect on intrafraction motion. Materials and methods: Pre and during radiotherapy rectal volumes and intrafraction motion were retrospectively calculated for 20 patients treated in 5-fractions and 20 treated in 20-fractions. Small (rectal volume at planning-CT ≤ median), and large (volume > median) subgroups were formed, and rectal volume between timepoints and subgroups compared. Rectal volume and intrafraction motion correlation was examined using Spearman's rho. Intrafraction motion difference between small and large subgroups and between fractions with rectal volume < or ≥ 90 cm3 were assessed. Results: Median rectal volume was 74 cm3, 64 cm3 and 65 cm3 on diagnostic-MRI, planning-CT and treatment imaging respectively (ns). No significant correlation was found between patient's rectal volume at planning-CT and median intrafraction motion, nor treatment rectal volume and intrafraction motion for individual fractions. No significant difference in intrafraction motion between small and large subgroups presented and for fractions where rectal volume breached 90 cm3, motion during that fraction was not significantly greater. Conclusion: Larger rectal volumes before radiotherapy and during treatment did not cause greater intrafraction motion. Findings support the relaxation of strict rectal diameter tolerances and do not support the need for rectal preparation when delivering contemporary IGRT to the prostate.
RESUMO
AIMS: Neoadjuvant chemoradiotherapy followed by surgery is the mainstay of treatment for patients with rectal cancer. Standard clinical target volume (CTV) to planning target volume (PTV) margins of 10 mm are used to accommodate inter- and intrafraction motion of target. Treating on magnetic resonance-integrated linear accelerators (MR-linacs) allows for online manual recontouring and adaptation (MRgART) enabling the reduction of PTV margins. The aim of this study was to investigate motion of the primary CTV (CTVA; gross tumour volume and macroscopic nodes with 10 mm expansion to cover microscopic disease) in order to develop a simultaneous integrated boost protocol for use on MR-linacs. MATERIALS AND METHODS: Patients suitable for neoadjuvant chemoradiotherapy were recruited for treatment on MR-linac using a two-phase technique; only the five phase 1 fractions on MR-linac were used for analysis. Intrafraction motion of CTVA was measured between pre-treatment and post-treatment MRI scans. In MRgART, isotropically expanded pre-treatment PTV margins from 1 to 10 mm were rigidly propagated to post-treatment MRI to determine overlap with 95% of CTVA. The PTV margin was considered acceptable if overlap was >95% in 90% of fractions. To understand the benefit of MRgART, the same methodology was repeated using a reference computed tomography planning scan for pre-treatment imaging. RESULTS: In total, nine patients were recruited between January 2018 and December 2020 with T3a-T4, N0-N2, M0 disease. Forty-five fractions were analysed in total. The median motion across all planes was 0 mm, demonstrating minimal intrafraction motion. A PTV margin of 3 and 5mm was found to be acceptable in 96 and 98% of fractions, respectively. When comparing to the computed tomography reference scan, the analysis found that PTV margins to 5 and 10 mm only acceptably covered 51 and 76% of fractions, respectively. CONCLUSION: PTV margins can be reduced to 3-5 mm in MRgART for rectal cancer treatment on MR-linac within an simultaneous integrated boost protocol.
Assuntos
Radioterapia Guiada por Imagem , Radioterapia de Intensidade Modulada , Neoplasias Retais , Humanos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Guiada por Imagem/métodos , Tomografia Computadorizada por Raios X , Neoplasias Retais/diagnóstico por imagem , Neoplasias Retais/radioterapia , Neoplasias Retais/patologia , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodosRESUMO
PURPOSE: The goal of this work was to compare different methods of incorporating the additional dose of mega-voltage cone-beam CT (MV-CBCT) for image-guided intensity modulated radiotherapy (IMRT) of different tumor entities. MATERIAL AND METHODS: The absolute dose delivered by the MV-CBCT was calculated and considered by creating a scaled IMRT plan (scIMRT) by renormalizing the clinically approved plan (orgIMRT) so that the sum with the MV-CBCT dose yields the same prescribed dose. In the other case, a newly optimized plan (optIMRT) was generated by including the dose distribution of the MV-CBCT as pre-irradiation. Both plans were compared with the orgIMRT plan and a plan where the last fraction was skipped. RESULTS: No significant changes were observed regarding the 95% conformity index of the target volume. The mean dose of the organs at risk (OAR) increased by approx. 7% for the scIMRT plan and 5% for the optIMRT plan. A significant increase of the mean dose to the outline contour was observed, ranging from 3.1 ± 1.3% (optIMRT) to 13.0 ± 6.1% (scIMRT) for both methods over all entities. If the dose of daily MV-CBCT would have been ignored, the additional dose accumulated to nearly a whole treatment fraction with a general increase of approx. 10% to the OARs and approx. 4% to the target volume. CONCLUSION: Both methods of incorporating the additional MV-CBCT dose into the treatment plan are suitable for clinical practice. The dose distribution of the target volume could be achieved as conformal as with the orgIMRT plan, while only a moderate increase of mean dose to OAR was observed.
Assuntos
Carga Corporal (Radioterapia) , Tomografia Computadorizada de Feixe Cônico/métodos , Radiometria , Dosagem Radioterapêutica , Radioterapia Conformacional/métodos , Radioterapia Guiada por Imagem/métodos , HumanosRESUMO
AIMS: With interest in normal tissue sparing and dose-escalated radiotherapy in the treatment of inoperable locally advanced non-small cell lung cancer, this study investigated the impact of motion-managed moderate deep inspiration breath hold (mDIBH) on normal tissue sparing and dose-escalation potential and compared this to planning with a four-dimensional motion-encompassing internal target volume or motion-compensating mid-ventilation approach. MATERIALS AND METHODS: Twenty-one patients underwent four-dimensional and mDIBH planning computed tomography scans. Internal and mid-ventilation target volumes were generated on the four-dimensional scan, with mDIBH target volumes generated on the mDIBH scan. Isotoxic target dose-escalation guidelines were used to generate six plans per patient: three with a target dose cap and three without. Target dose-escalation potential, normal tissue complication probability and differences in pre-specified dose-volume metrics were evaluated for the three motion-management techniques. RESULTS: The mean total lung volume was significantly greater with mDIBH compared with four-dimensional scans. Lung dose (mean and V21 Gy) and mean heart dose were significantly reduced with mDIBH in comparison with four-dimensional-based approaches, and this translated to a significant reduction in heart and lung normal tissue complication probability with mDIBH. In 20/21 patients, the trial target prescription dose cap of 79.2 Gy was achievable with all motion-management techniques. CONCLUSION: mDIBH aids lung and heart dose sparing in isotoxic dose-escalated radiotherapy compared with four-dimensional planning techniques. Given concerns about lung and cardiac toxicity, particularly in an era of consolidation immunotherapy, reduced normal tissue doses may be advantageous for treatment tolerance and outcome.
Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Suspensão da Respiração , Carcinoma Pulmonar de Células não Pequenas/radioterapia , Humanos , Pulmão , Neoplasias Pulmonares/radioterapia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodosRESUMO
A shift of the daily plan can mitigate target position changes that occur between daily MR acquisition and treatment for MR-linac radiotherapy, but increases the session time. We demonstrated that our workflow strategy and decision-making process, to determine whether a subsequent shift is necessary, is appropriate.
RESUMO
Bladder tumour-focused magnetic resonance image-guided adaptive radiotherapy using a 1.5 Tesla MR-linac is feasible. A full online workflow adapting to anatomy at each fraction is achievable in approximately 30 min. Intra-fraction bladder filling did not compromise target coverage with the class solution employed.
RESUMO
AIMS: Prostate morphological changes during external beam radiotherapy are poorly understood. Excellent soft-tissue visualisation offered by magnetic resonance image-guided radiotherapy (MRIgRT) provides an opportunity to better understand such changes. The aim of this study was to quantify prostate volume and dimension changes occurring during extreme and moderately hypofractionated schedules. MATERIALS AND METHODS: Forty prostate cancer patients treated on the Unity 1.5 Tesla magnetic resonance linear accelerator (MRL) were retrospectively reviewed. The cohort comprised patients treated with 36.25 Gy in five fractions (n = 20) and 60 Gy in 20 fractions (n = 20). The volume of the delineated prostates on reference planning computed tomography (fused with MRI) and daily T2-weighted 2-min session images acquired on Unity were charted. Forty planning computed tomography and 500 MRL prostate volumes were evaluated. The mean absolute and relative change in prostate volume during radiotherapy was compared using a paired t-test (P value <0.01 considered significant to control for multiple comparisons). The maximum dimension of the delineated prostate was measured in three isocentric planes. RESULTS: Significant prostate volume changes, relative to MRL imaging fraction 1 (MRL#1), were seen at all time points for the five-fraction group. The peak mean relative volume increase was 21% (P < 0.001), occurring at MRL#3 and MRL#4 after 14.5 and 21.75 Gy, respectively. Prostate expansion was greatest in the superior-inferior direction; the peak mean maximal extension was 5.9 mm. The maximal extension in the left-right and anterior-posterior directions measured 1.1 and 2.2 mm, respectively. For the 20-fraction group, prostate volume increased relative to MRL#1, for all treatment time points. The mean relative volume increase was 11% (P < 0.001) at MRL#5 after 12 Gy, it then fluctuated between 8 and 13%. From MRL#5 to MRL#20, the volume increase was significant (P < 0.01) for 12 of 16 time points calculated. The peak mean maximal extension in the superior-inferior direction was 3.1 mm. The maximal extension in the left-right and anterior-posterior directions measured 1.7 and 3.7 mm, respectively. CONCLUSION: Significant prostate volume and dimension changes occur during extreme and moderately hypofractionated radiotherapy. The extent of change was greater during extreme hypofractionation. MRIgRT offers the opportunity to reveal, quantify and correct for this deformation.
Assuntos
Neoplasias da Próstata , Radioterapia Guiada por Imagem , Radioterapia de Intensidade Modulada , Humanos , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética , Masculino , Próstata/diagnóstico por imagem , Próstata/patologia , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Guiada por Imagem/métodos , Radioterapia de Intensidade Modulada/métodos , Estudos RetrospectivosRESUMO
AIMS: Target delineation uncertainty is arguably the largest source of geometric uncertainty in radiotherapy. Several factors can affect it, including the imaging modality used for delineation. It is accounted for by applying safety margins to the target to produce a planning target volume (PTV), to which treatments are designed. To determine the margin, the delineation uncertainty is measured as the delineation error, and then a margin recipe used. However, there is no published evidence of such analysis for recurrent gynaecological cancers (RGC). The aims of this study were first to quantify the delineation uncertainty for RGC gross tumour volumes (GTVs) and to calculate the associated PTV margins and then to quantify the difference in GTV, delineation uncertainty and PTV margin, between a computed tomography-magnetic resonance imaging (CT-MRI) and MRI workflow. MATERIALS AND METHODS: Seven clinicians delineated the GTV for 20 RGC tumours on co-registered CT and MRI datasets (CT-MRI) and on MRI alone. The delineation error, the standard deviation of distances from each clinician's outline to a reference, was measured and the required PTV margin determined. Differences between using CT-MRI and MRI alone were assessed. RESULTS: The overall delineation error and the resulting margin were 3.1 mm and 8.5 mm, respectively, for CT-MRI, reducing to 2.5 mm and 7.1 mm, respectively, for MRI alone. Delineation errors and therefore the theoretical margins, varied widely between patients. MRI tumour volumes were on average 15% smaller than CT-MRI tumour volumes. DISCUSSION: This study is the first to quantify delineation error for RGC tumours and to calculate the corresponding PTV margin. The determined margins were larger than those reported in the literature for similar patients, bringing into question both current margins and margin calculation methods. The wide variation in delineation error between these patients suggests that applying a single population-based margin may result in PTVs that are suboptimal for many. Finally, the reduced tumour volumes and safety margins suggest that patients with RGC may benefit from an MRI-only treatment workflow.
Assuntos
Neoplasias , Planejamento da Radioterapia Assistida por Computador , Humanos , Imageamento por Ressonância Magnética , Tomografia Computadorizada por Raios X , Carga TumoralRESUMO
Previous work has shown that PRESAGE® can be used successfully to perform 3D dosimetric measurements of complex radiotherapy treatments. However, measurements near the sample edges are known to be difficult to achieve. This is an issue when the doses at air-material interfaces are of interest, for example when investigating the electron return effect (ERE) present in treatments delivered by magnetic resonance (MR)-linac systems. To study this effect, a set of 3.5 cm-diameter cylindrical PRESAGE® samples was uniformly irradiated with multiple dose fractions, using either a conventional linac or an MR-linac. The samples were imaged between fractions using an optical-CT, to read out the corresponding accumulated doses. A calibration between TPS-predicted dose and optical-CT pixel value was determined for individual dosimeters as a function of radial distance from the axis of rotation. This data was used to develop a correction that was applied to four additional samples of PRESAGE® of the same formulation, irradiated with 3D-CRT and IMRT treatment plans, to recover significantly improved 3D measurements of dose. An alternative strategy was also tested, in which the outer surface of the sample was physically removed prior to irradiation. Results show that for the formulation studied here, PRESAGE® samples have a central region that responds uniformly and an edge region of 6-7 mm where there is gradual increase in dosimeter response, rising to an over-response of 24%-36% at the outer boundary. This non-uniform dose response increases in both extent and magnitude over time. Both mitigation strategies investigated were successful. In our four exemplar studies, we show how discrepancies at edges are reduced from 13%-37% of the maximum dose to between 2 and 8%. Quantitative analysis shows that the 3D gamma passing rates rise from 90.4, 69.3, 63.7 and 43.6% to 97.3, 99.9, 96.7 and 98.9% respectively.
Assuntos
Imageamento Tridimensional/instrumentação , Neoplasias Pulmonares/radioterapia , Aceleradores de Partículas/instrumentação , Imagens de Fantasmas , Radiometria/instrumentação , Planejamento da Radioterapia Assistida por Computador/métodos , Calibragem , Raios gama , Humanos , Imageamento Tridimensional/métodos , Radiometria/métodos , Dosagem Radioterapêutica , Radioterapia Conformacional/métodosRESUMO
Whole bladder magnetic resonance image-guided radiotherapy using the 1.5 Telsa MR-linac is feasible. Full online adaptive planning workflow based on the anatomy seen at each fraction was performed. This was delivered within 45 min. Intra-fraction bladder filling did not compromise target coverage. Patients reported acceptable tolerance of treatment.
RESUMO
In recent experiments, quasi-monoenergetic and well-collimated very-high energy electron (VHEE) beams were obtained by laser-plasma accelerators. We investigate their potential use for radiation therapy. Monte Carlo simulations are used to study the influence of the experimental characteristics such as beam energy, energy spread and initial angular distribution on the dose distributions. It is found that magnetic focusing of the electron beam improves the lateral penumbra. The dosimetric properties of the laser-accelerated VHEE beams are implemented in our inverse treatment planning system for intensity-modulated treatments. The influence of the beam characteristics on the quality of a prostate treatment plan is evaluated. In comparison to a clinically approved 6 MV IMRT photon plan, a better target coverage is achieved. The quality of the sparing of organs at risk is found to be dependent on the depth. The bladder and rectum are better protected due to the sharp lateral penumbra at low depths, whereas the femoral heads receive a larger dose because of the large scattering amplitude at larger depths.
Assuntos
Elétrons/uso terapêutico , Lasers , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Alta Energia , Simulação por Computador , Humanos , Magnetismo/métodos , Masculino , Método de Monte Carlo , Neoplasias da Próstata/radioterapia , Dosagem Radioterapêutica , Água/químicaRESUMO
Geometric uncertainties in radiotherapy are conventionally addressed by defining a safety margin around the radiotherapy target. Misappropriation of such margins could result in disease recurrence from geometric miss or unnecessary irradiation of normal tissue. Numerous quantitative organ motion studies in adults have been published, but the first paediatric-specific studies were only published in recent years. In the very near future, intensity-modulated proton beam therapy and magnetic resonance-guided radiotherapy will be clinically implemented in the UK. Such techniques offer the ability to deliver radiotherapy to the pinnacle of precision and accuracy, if geometric uncertainty relating to internal organ motion and deformation can be optimally managed. The optimal margin to account for internal organ motion in children remains largely undefined. Continuing efforts to characterise motion in children and young people is necessary to optimally define safety margins and to realise the full potential of intensity-modulated radiotherapy, magnetic resonance-guided radiotherapy and intensity-modulated proton beam therapy. This overview offers a timely review of published reports on paediatric organ motion, in anticipation of the increasing application of advanced radiotherapy techniques in paediatric radiotherapy.
Assuntos
Neoplasias Encefálicas/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Adolescente , Criança , Humanos , Prognóstico , Dosagem RadioterapêuticaRESUMO
The sharp dose gradients which are possible in intensity modulated proton therapy (IMPT) not only offer the possibility of generating excellent target coverage while sparing neighbouring organs at risk, but can also lead to treatment plans which are very sensitive to uncertainties in treatment variables such as the range of individual Bragg peaks. We developed a method to account for uncertainties of treatment variables in the optimization based on a worst case dose distribution. The worst case dose distribution is calculated using several possible realizations of the uncertainties. This information is used by the objective function of the inverse treatment planning system to generate treatment plans which are acceptable under all considered realizations of the uncertainties. The worst case optimization method was implemented in our in-house treatment planning software KonRad in order to demonstrate the usefulness of this approach for clinical cases. In this paper, we investigated range uncertainties, setup uncertainties and a combination of both uncertainties. Using our method the sensitivity of the resulting treatment plans to these uncertainties is considerably reduced.
Assuntos
Terapia com Prótons , Radioterapia de Intensidade Modulada , Incerteza , Humanos , Dosagem RadioterapêuticaRESUMO
Laser-induced particle accelerators have been recognized as a potential proton source for radiotherapeutic applications in recent years. However, there are still major difficulties--especially regarding the resulting proton spectra--to overcome for a successful application in the clinic. Here we elaborate on the physics of double-layer targets to propose a tentative 'optical gantry' setup. The spectral requirements for a quality dose deposition of the fast protons are estimated. Plasma simulations of the one-dimensional expansion of microstructured targets are performed according to various target dimensions, rear proton densities and substrate masses. Subsequently, the dependence of the resulting proton spectra on these parameters is evaluated and compared to previously published analytical considerations. Quasi-monoenergetic proton beams, which would be suitable for high-quality dose delivery, could be achieved from pure proton targets if one were able to select out the rear layer of those targets. However, much more realistic heavy substrate layered targets are not able to preserve this high spectral standard, partly due to a second Coulomb-expansion in the center-of-mass frame of the fast protons. This expansion can be mitigated by a reduction of the total positive charge in the rear layer, resulting in a comparable spectral quality as the previous target types. In conclusion, the promising spectral results as well as an estimation of the total number of fast protons which can be expected from such a setup, suggest that the introduction of laser-based proton accelerators into the clinic might be possible in the future.
Assuntos
Carga Corporal (Radioterapia) , Terapia a Laser/métodos , Modelos Biológicos , Aceleradores de Partículas , Terapia com Prótons , Radiometria/métodos , Análise Espectral , Simulação por Computador , Humanos , Dosagem RadioterapêuticaRESUMO
Intrafractional organ motion remains a source of error in conformal radiotherapy of dynamic targets such as tumours of the lung or of the prostate. The purpose of this work was to devise a method for the continuous and routine measurement of intrafractional organ motion. The method consists of a combination of an electromagnetic (EM), internal marker-based tracking system with the on-board kilovoltage x-ray imaging system of a modern treatment machine. The EM system continuously tracks the target, while x-ray images can be acquired simultaneously if demand arises. An image processing algorithm has been developed to automatically localize and track the EM markers in the x-ray images. We have demonstrated simultaneous target tracking using the EM system and x-ray imaging of a mobile target inside a programmable thorax phantom. The target motion was very well reproduced by both systems. The comparability of the target locations reported by both systems was established (better than 0.25 mm up to target velocities of 3 cm s(-1)). One immediate use of the synchronized system was shown: the generation of a 4D cone beam computed tomography data set using the EM system for the measurement of motion. In conclusion, we have developed a system for the routine measurement of intrafractional motion that continuously provides the 3D position of the target with the ability to acquire images of the treatment field only when needed, thereby eliminating avoidable imaging dose to the patient.
Assuntos
Fenômenos Eletromagnéticos , Movimento , Neoplasias/diagnóstico por imagem , Neoplasias/fisiopatologia , Imagens de Fantasmas , Radiografia Torácica/instrumentação , Tomografia Computadorizada de Feixe Cônico , Humanos , Processamento de Imagem Assistida por Computador , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/fisiopatologia , Neoplasias Pulmonares/radioterapia , Neoplasias/radioterapia , Padrões de Referência , Fatores de TempoRESUMO
Margins are employed in radiotherapy treatment planning to mitigate the dosimetric effects of geometric uncertainties for the clinical target volume (CTV). Unfortunately, whilst the use of margins can increase the probability that sufficient dose is delivered to the CTV, it can also result in delivering high dose of radiation to surrounding organs at risk (OARs). We expand on our previous work on beam-dependent margins and propose a novel adaptive margin concept, where margins are moulded away from selected OARs for better OAR-high-dose sparing, whilst maintaining similar dose coverage probability to the CTV. This, however, comes at a cost of a larger irradiation volume, and thus can negatively impact other structures. We investigate the impact of the adaptive margin concept when applied to prostate radiotherapy treatments, and compare treatment plans generated using our beam-dependent margins without adaptation, with adaption from the rectum and with adaptation from both the rectum and bladder. Five prostate patients were used in this planning study. All plans achieved similar dose coverage probability, and were able to ensure at least 90% population coverage with the target receiving at least 95% of the prescribed dose to [Formula: see text]. We observed overall better high-dose sparing to OARs that were considered when using the adapted beam-dependent PTVs, with the degree of sparing dependent on both the number of OARs under consideration as well as the relative position between the CTV and the OARs.
Assuntos
Órgãos em Risco/efeitos da radiação , Planejamento da Radioterapia Assistida por Computador/métodos , Humanos , Masculino , Probabilidade , Neoplasias da Próstata/radioterapia , Radiometria , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada , Reto/efeitos da radiação , IncertezaRESUMO
Adaptive radiotherapy (ART) strategies systematically monitor variations in target and neighbouring structures to inform treatment-plan modification during radiotherapy. This is necessary because a single plan designed before treatment is insufficient to capture the actual dose delivered to the target and adjacent critical structures during the course of radiotherapy. Magnetic resonance imaging (MRI) provides superior soft-tissue image contrast over current standard X-ray-based technologies without additional radiation exposure. With integrated MRI and radiotherapy platforms permitting motion monitoring during treatment delivery, it is possible that adaption can be informed by real-time anatomical imaging. This allows greater treatment accuracy in terms of dose delivered to target with smaller, individualised treatment margins. The use of functional MRI sequences would permit ART to be informed by imaging biomarkers, so allowing both personalised geometric and biological adaption. In this review, we discuss ART solutions enabled by MRI guidance and its potential gains for our patients across tumour types.
Assuntos
Imageamento por Ressonância Magnética/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Assistida por Computador/métodos , Radioterapia Guiada por Imagem/métodos , HumanosRESUMO
Combined radiotherapy and hyperthermia offer great potential for the successful treatment of radio-resistant tumours through thermo-radiosensitization. Tumour response heterogeneity, due to intrinsic, or micro-environmentally induced factors, may greatly influence treatment outcome, but is difficult to account for using traditional treatment planning approaches. Systems oncology simulation, using mathematical models designed to predict tumour growth and treatment response, provides a powerful tool for analysis and optimization of combined treatments. We present a framework that simulates such combination treatments on a cellular level. This multiscale hybrid cellular automaton simulates large cell populations (up to 107 cells) in vitro, while allowing individual cell-cycle progression, and treatment response by modelling radiation-induced mitotic cell death, and immediate cell kill in response to heating. Based on a calibration using a number of experimental growth, cell cycle and survival datasets for HCT116 cells, model predictions agreed well (R2 > 0.95) with experimental data within the range of (thermal and radiation) doses tested (0-40 CEM43, 0-5 Gy). The proposed framework offers flexibility for modelling multimodality treatment combinations in different scenarios. It may therefore provide an important step towards the modelling of personalized therapies using a virtual patient tumour.