Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Radiat Res ; 62(1): 149-154, 2021 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-33392616

RESUMO

The postoperative hypofractionated intensity-modulated radiation therapy (POHIM-RT) trial is a phase II study to evaluate toxicity following hypofractionated intensity modulated radiation therapy (IMRT) for cervical cancer. This study describes the results of a benchmark procedure for RT quality assurance of the POHIM-RT trial. Six participating institutions were provided computed tomography for RT planning and an IMRT plan for a sample and were instructed to delineate volumes, create a treatment plan and quality assurance (QA) plan, and submit the results of all procedures. The inter-institutional agreements on RT volume and plan results were evaluated using the kappa value and dice similarity coefficients. The simultaneous truth and performance level estimation (STAPLE) method was employed to generate a consensus target volume. The treatment volumes, organs-at-risk volumes, and results of the RT plan and QA reported by the institutions were acceptable and adhered well to the protocol. In terms of clinical target volume (CTV) delineation, there were differences between the institutions, particularly in vaginal cuff and paracolpium subsites. Consensus CTV was generated from the collected CTVs with the STAPLE method. The participating institutions showed considerable agreement regarding volume, dose and QA results. To improve CTV agreement in CTV, we provided feedback with images of the consensus target volume and detailed written guidelines for specific subsites that were the most heterogeneous.


Assuntos
Hipofracionamento da Dose de Radiação , Radioterapia de Intensidade Modulada , Neoplasias do Colo do Útero/radioterapia , Neoplasias do Colo do Útero/cirurgia , Feminino , Humanos , Órgãos em Risco/efeitos da radiação , Período Pós-Operatório , Garantia da Qualidade dos Cuidados de Saúde , Planejamento da Radioterapia Assistida por Computador , Tomografia Computadorizada por Raios X , Neoplasias do Colo do Útero/diagnóstico por imagem
2.
Radiat Oncol J ; 38(1): 60-67, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32229810

RESUMO

PURPOSE: We performed three-dimensional (3D) dose reconstruction-based pretreatment verification to evaluate gamma analysis acceptance criteria in volumetric modulated arc therapy (VMAT) for prostate cancer. MATERIALS AND METHODS: Pretreatment verification for 28 VMAT plans for prostate cancer was performed using the COMPASS system with a dolphin detector. The 3D reconstructed dose distribution of the treatment planning system calculation (TC) was compared with that of COMPASS independent calculation (CC) and COMPASS reconstruction from the dolphin detector measurement (CR). Gamma results (gamma failure rate and average gamma value [GFR and γAvg]) and dose-volume histogram (DVH) deviations, 98%, 2% and mean dose-volume difference (DD98%, DD2% and DDmean), were evaluated. Gamma analyses were performed with two acceptance criteria, 2%/2 mm and 3%/3 mm. RESULTS: The GFR in 2%/2 mm criteria were less than 8%, and those in 3%/3 mm criteria were less than 1% for all structures in comparisons between TC, CC, and CR. In the comparison between TC and CR, GFR and γAvg in 2%/2 mm criteria were significantly higher than those in 3%/3 mm criteria. The DVH deviations were within 2%, except for DDmean (%) for rectum and bladder. CONCLUSIONS: The 3%/3 mm criteria were not strict enough to identify any discrepancies between planned and measured doses, and DVH deviations were less than 2% in most parameters. Therefore, gamma criteria of 2%/2 mm and DVH related parameters could be a useful tool for pretreatment verification for VMAT in prostate cancer.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA