Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 62
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Eur Radiol ; 33(5): 3501-3509, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36624227

RESUMO

OBJECTIVES: To externally validate the performance of a commercial AI software program for interpreting CXRs in a large, consecutive, real-world cohort from primary healthcare centres. METHODS: A total of 3047 CXRs were collected from two primary healthcare centres, characterised by low disease prevalence, between January and December 2018. All CXRs were labelled as normal or abnormal according to CT findings. Four radiology residents read all CXRs twice with and without AI assistance. The performances of the AI and readers with and without AI assistance were measured in terms of area under the receiver operating characteristic curve (AUROC), sensitivity, and specificity. RESULTS: The prevalence of clinically significant lesions was 2.2% (68 of 3047). The AUROC, sensitivity, and specificity of the AI were 0.648 (95% confidence interval [CI] 0.630-0.665), 35.3% (CI, 24.7-47.8), and 94.2% (CI, 93.3-95.0), respectively. AI detected 12 of 41 pneumonia, 3 of 5 tuberculosis, and 9 of 22 tumours. AI-undetected lesions tended to be smaller than true-positive lesions. The readers' AUROCs ranged from 0.534-0.676 without AI and 0.571-0.688 with AI (all p values < 0.05). For all readers, the mean reading time was 2.96-10.27 s longer with AI assistance (all p values < 0.05). CONCLUSIONS: The performance of commercial AI in these high-volume, low-prevalence settings was poorer than expected, although it modestly boosted the performance of less-experienced readers. The technical prowess of AI demonstrated in experimental settings and approved by regulatory bodies may not directly translate to real-world practice, especially where the demand for AI assistance is highest. KEY POINTS: • This study shows the limited applicability of commercial AI software for detecting abnormalities in CXRs in a health screening population. • When using AI software in a specific clinical setting that differs from the training setting, it is necessary to adjust the threshold or perform additional training with such data that reflects this environment well. • Prospective test accuracy studies, randomised controlled trials, or cohort studies are needed to examine AI software to be implemented in real clinical practice.


Assuntos
Inteligência Artificial , Pneumopatias , Radiografia Torácica , Software , Humanos , Prevalência , Software/normas , Radiografia Torácica/métodos , Radiografia Torácica/normas , Reprodutibilidade dos Testes , Pulmão/diagnóstico por imagem , Pneumopatias/diagnóstico por imagem , Estudos de Coortes , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso
2.
Eur Radiol ; 33(3): 1963-1972, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36112191

RESUMO

OBJECTIVE: To demonstrate the relationship between spectral computed tomography (CT) measured iodine concentration and strength of aortic valvular calcification (AVC) in patients with aortic valve stenosis (AVS). METHODS: A retrospective study was performed on patients who underwent transcatheter aortic valve replacement (TAVR) for symptomatic AVS and underwent both pre and postprocedural electrocardiogram gated CT scans using a spectral CT system. Preprocedural CT was used to evaluate the volume and iodine concentration (IC) in the AVC. Postprocedural CT data were used to calculate the volume reduction percentage (VRP) of AVC. Multiple linear regression analysis was used to identify the independent variables related to the VRP in AVCs. RESULTS: A total of 94 AVCs were selected from 22 patients. The mean volume and IC of the AVCs before TAVR were 0.37 mL ± 0.15 mL and 7 mg/mL ± 10.5 mg/mL, respectively. After TAVR, a median VRP of all 94 AVCs was 18.5%. Multiple linear regression analysis showed that the IC was independently associated with the VRP (coefficient = 1.64, p < 0.001). When an optimal IC cutoff point was set at 4 mg/mL in the assessment of a fragile AVC which showed the VRP was > 18.5%, the sensitivity was 63%; specificity, 91%; positive predictive value, 88%; and negative predictive value, 71%. CONCLUSIONS: When using spectral CT to prepare the TAVR, measuring the IC of the AVC may be useful to assess the probability of AVC deformity after TAVR. KEY POINTS: • A dual-layer detector-based spectral CT enables quantifying iodine of contrast media in the aortic valve calcification (AVC) on contrast-enhanced CT images. • The AVC including iodine of contrast media on contrast-enhanced CT image may have loose compositions, associated with the deformity of AVC after TAVR. • Measuring the iodine concentration in AVC may have the potential to assess the probability of AVC deformity, which may be associated with the outcome and complications after TAVR.2.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Meios de Contraste/farmacologia , Estudos Retrospectivos , Fatores de Risco , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Tomografia Computadorizada por Raios X/métodos , Índice de Gravidade de Doença
3.
Eur Radiol ; 33(3): 1973-1981, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36152039

RESUMO

OBJECTIVES: To evaluate commercial deep learning-based software for fully automated coronary artery calcium (CAC) scoring on non-electrocardiogram (ECG)-gated low-dose CT (LDCT) with different slice thicknesses compared with manual ECG-gated calcium-scoring CT (CSCT). METHODS: This retrospective study included 567 patients who underwent both LDCT and CSCT. All LDCT images were reconstructed with a 2.5-mm slice thickness (LDCT2.5-mm), and 453 LDCT scans were reconstructed with a 1.0-mm slice thickness (LDCT1.0-mm). Automated CAC scoring was performed on CSCT (CSCTauto), LDCT1.0-mm, and LDCT2.5-mm images. The reliability of CSCTauto, LDCT1.0-mm, and LDCT2.5-mm was compared with manual CSCT scoring (CSCTmanual) using intraclass correlation coefficients (ICCs) and Bland-Altman analysis. Agreement, in CAC severity category, was analyzed using weighted kappa statistics. Diagnostic performance at various Agatston score cutoffs was also calculated. RESULTS: CSCTauto, LDCT1.0-mm, and LDCT2.5-mm demonstrated excellent agreement with CSCTmanual (ICC [95% confidence interval, CI]: 1.000 [1.000, 1.000], 0.937 [0.917, 0.952], and 0.955 [0.946, 0.963], respectively). The mean difference with 95% limits of agreement was lower with LDCT1.0-mm than with LDCT2.5-mm (19.94 [95% CI, -244.0, 283.9] vs. 45.26 [-248.2, 338.7]). Regarding CAC severity, LDCT1.0-mm achieved almost perfect agreement, and LDCT2.5-mm achieved substantial agreement (kappa [95% CI]: 0.809 [0.776, 0.838], 0.776 [0.740, 0.809], respectively). Diagnostic performance for detecting Agatston score ≥ 400 was also higher with LDCT1.0-mm than with LDCT2.5-mm (F1 score, 0.929 vs. 0.855). CONCLUSIONS: Fully automated CAC-scoring software with both CSCT and LDCT yielded excellent reliability and agreement with CSCTmanual. LDCT1.0-mm yielded more accurate Agatston scoring than LDCT2.5-mm using fully automated commercial software. KEY POINTS: • Total Agatston scores and all vessels of CSCTauto, LDCT1.0-mm, and LDCT2.5-mm demonstrated excellent agreement with CSCTmanual (all ICC > 0.85). • The diagnostic performance for detecting all Agatston score cutoffs was better with LDCT1.0-mm than with LDCT2.5-mm. • This automated software yielded a lower degree of underestimation compared with methods described in previous studies, and the degree of underestimation was lower with LDCT1.0-mm than with LDCT2.5-mm.


Assuntos
Cálcio , Doença da Artéria Coronariana , Humanos , Doença da Artéria Coronariana/diagnóstico , Reprodutibilidade dos Testes , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Software , Vasos Coronários , Angiografia Coronária/métodos
4.
J Korean Med Sci ; 38(37): e306, 2023 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-37724499

RESUMO

BACKGROUND: To propose a deep learning architecture for automatically detecting the complex structure of the aortic annulus plane using cardiac computed tomography (CT) for transcatheter aortic valve replacement (TAVR). METHODS: This study retrospectively reviewed consecutive patients who underwent TAVR between January 2017 and July 2020 at a tertiary medical center. Annulus Detection Permuted AdaIN network (ADPANet) based on a three-dimensional (3D) U-net architecture was developed to detect and localize the aortic annulus plane using cardiac CT. Patients (N = 72) who underwent TAVR between January 2017 and July 2020 at a tertiary medical center were enrolled. Ground truth using a limited dataset was delineated manually by three cardiac radiologists. Training, tuning, and testing sets (70:10:20) were used to build the deep learning model. The performance of ADPANet for detecting the aortic annulus plane was analyzed using the root mean square error (RMSE) and dice similarity coefficient (DSC). RESULTS: In this study, the total dataset consisted of 72 selected scans from patients who underwent TAVR. The RMSE and DSC values for the aortic annulus plane using ADPANet were 55.078 ± 35.794 and 0.496 ± 0.217, respectively. CONCLUSION: Our deep learning framework was feasible to detect the 3D complex structure of the aortic annulus plane using cardiac CT for TAVR. The performance of our algorithms was higher than other convolutional neural networks.


Assuntos
Aprendizado Profundo , Substituição da Valva Aórtica Transcateter , Humanos , Estudos Retrospectivos , Radiografia , Tomografia
5.
Eur Radiol ; 32(3): 1902-1911, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34564746

RESUMO

OBJECTIVES: To explore the importance of quantitative characteristics of dual-energy CT (DECT) between pulmonary metastasis and benign lung nodules in thyroid cancer. METHODS: In this retrospective study, we identified 63 patients from our institution's database with pathologically proven thyroid cancer who underwent DECT to assess pulmonary metastasis. Among these patients, 22 had 55 pulmonary metastases, and 41 had 97 benign nodules. If nodules showed increased iodine uptake on I-131 single-photon emission computed tomography-computed tomography or increased size in follow-up CT, they were considered metastatic. We compared the clinical findings and DECT parameters of both groups and performed a receiver operating characteristic analysis to evaluate the optimal cutoff values of the DECT parameters. RESULTS: Patients with metastases were significantly older than patients with benign nodules (p = 0.048). The DECT parameters of the metastatic nodules were significantly higher than those of the benign nodules (iodine concentration [IC], 5.61 ± 2.02 mg/mL vs. 1.61 ± 0.98 mg/mL; normalized IC [NIC], 0.60 ± 0.20 vs. 0.16 ± 0.11; NIC using pulmonary artery [NICPA], 0.60 ± 0.44 vs. 0.15 ± 0.11; slope of the spectral attenuation curves [λHU], 5.18 ± 2.54 vs. 2.12 ± 1.39; and Z-effective value [Zeff], 10.0 ± 0.94 vs. 8.79 ± 0.75; all p < 0.001). In the subgroup analysis according to nodule size, all DECT parameters of the metastatic nodules in all subgroups were significantly higher than those of the benign nodules (all p < 0.05). The cutoff values for IC, NIC, λHU, NICPA, and Zeff for diagnosing metastases were 3.10, 0.29, 3.57, 0.28, and 9.34, respectively (all p < 0.001). CONCLUSIONS: DECT parameters can help to differentiate metastatic and benign lung nodules in thyroid cancer. KEY POINTS: • DECT parameters can help to differentiate metastatic and benign lung nodules in patients with thyroid cancer. • DECT parameters showed a significant difference between benign lung nodules and lung metastases, even for nodules with diameters ≥ 3 mm and < 5 mm. • Among the DECT parameters, the highest diagnostic accuracy for differentiating pulmonary metastases from benign lung nodules was achieved with the NIC and IC, followed by the NICPA and λHU, and their cutoff values were 0.29, 3.10, 0.28, and 3.57, respectively.


Assuntos
Neoplasias Pulmonares , Neoplasias da Glândula Tireoide , Meios de Contraste , Humanos , Radioisótopos do Iodo , Pulmão , Neoplasias Pulmonares/diagnóstico por imagem , Estudos Retrospectivos , Neoplasias da Glândula Tireoide/diagnóstico por imagem , Tomografia Computadorizada por Raios X
6.
J Korean Med Sci ; 37(36): e271, 2022 Sep 19.
Artigo em Inglês | MEDLINE | ID: mdl-36123960

RESUMO

BACKGROUND: To propose fully automatic segmentation of left atrium using active learning with limited dataset in late gadolinium enhancement in cardiac magnetic resonance imaging (LGE-CMRI). METHODS: An active learning framework was developed to segment the left atrium in cardiac LGE-CMRI. Patients (n = 98) with atrial fibrillation from the Korea University Anam Hospital were enrolled. First, 20 cases were delineated for ground truths by two experts and used for training a draft model. Second, the 20 cases from the first step and 50 new cases, corrected in a human-in-the-loop manner after predicting using the draft model, were used to train the next model; all 98 cases (70 cases from the second step and 28 new cases) were trained. An additional 20 LGE-CMRI were evaluated in each step. RESULTS: The Dice coefficients for the three steps were 0.85 ± 0.06, 0.89 ± 0.02, and 0.90 ± 0.02, respectively. The biases (95% confidence interval) in the Bland-Altman plots of each step were 6.36% (-14.90-27.61), 6.21% (-9.62-22.03), and 2.68% (-8.57-13.93). Deep active learning-based annotation times were 218 ± 31 seconds, 36.70 ± 18 seconds, and 36.56 ± 15 seconds, respectively. CONCLUSION: Deep active learning reduced annotation time and enabled efficient training on limited LGE-CMRI.


Assuntos
Meios de Contraste , Gadolínio , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/patologia , Humanos , Imageamento por Ressonância Magnética/métodos , Redes Neurais de Computação
7.
J Cardiovasc Electrophysiol ; 32(3): 669-677, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33428249

RESUMO

INTRODUCTION: Hemodynamics of left atrial appendage (LAA) is an important factor for future risk of ischemic stroke in atrial fibrillation (AF) patients. Velocity encoded cardiac magnetic resonance imaging (VENC-MRI) can evaluate blood flow volume of LAA without any invasive procedures. We aimed to evaluate the association between radiofrequency catheter ablation (RFCA) and LAA hemodynamics measured by MRI. METHODS AND RESULTS: Consecutive RFCA cases in a single arrhythmia center were retrospectively analyzed. A total of 3120 AF patients who underwent first RFCA were analyzed. Among these patients 360 patients had both pre- and post-RFCA VENC-MRI evaluation. Atrial fibrillation was non-paroxysmal in 174 (48.3%) patients. Mean VENC-MRI (ml/sec) was significantly improved after RFCA with 49.93 ± 32.92 and 72.00 ± 34.82 for pre- and post-RFCA, respectively. Patients with non-paroxysmal AF (∆VENC-MRI = 14.63 ± 40.67 vs. 30.03 ± 35.37; p < .001) and low pre-RFCA VENC-MRI (∆VENC-MRI = 17.19 ± 38.35 vs. 50.35 ± 29.12; p < .001) had significantly higher improvement in VENC-MRI. Those who experienced late recurrence before post-RFCA MRI had significantly less improvement in LAA flow volume (∆VENC-MRI = 15.55 ± 41.41 vs. 26.18 ± 36.77; p = .011). Late recurrence and pre-RFCA VENC-MRI were significantly associated with ∆VENC-MRI after adjusting covariates. Patients who were AF before RFCA but maintained sinus rhythm after RFCA showed greatest improvement in VENC-MRI. CONCLUSION: Effective rhythm control through RFCA can be associated with significant improvement in LAA hemodynamics. Low pre-RFCA VENC-MRI and absence of late recurrence were associated with greater improvement in LAA hemodynamics.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Ablação por Cateter , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Hemodinâmica , Humanos , Imageamento por Ressonância Magnética , Recidiva , Estudos Retrospectivos
8.
Eur Radiol ; 31(1): 515-524, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32785771

RESUMO

OBJECTIVES: To compare the coronary vasodilation effects of spray with those induced by tablet administration in coronary CT angiography (CCTA). METHODS: A total of 2024 patients who underwent CCTA were identified for this retrospective study, including 828 patients with spray (spray group) and 1169 with tablets (tablet group). Of these, 93 patients underwent CCTA at least twice using both spray and tablets. The number of measurable segments and diameters of all 18 segments was measured. The number of measurable segments was compared between groups. RESULTS: No statistically significant differences were evident between these two groups in terms of clinical characteristics. All coronary segments except the ramus intermedius (RI) and left posterior descending artery (L-PDA) were significantly larger in the spray group than in the tablet group (all p < 0.001). In peripheral and branch vessels, as well as in central and main coronary arteries, the diameters were significantly larger in the spray group than in the tablet group (all p < 0.001). Although not always statistically significant, all coronary segments tended to be more measurable on CCTA with spray than with tablet. In the subgroup that underwent CCTA twice using both spray and tablets, all coronary segments except the RI, obtuse marginal artery 2 (OM2), and L-PDA were significantly larger in the spray group than in the tablet group (all p < 0.05). CONCLUSION: Lingual isosorbide dinitrate (ISDN) spray was more efficacious than sublingual nitroglycerin (NTG) tablets in coronary vasodilation for CCTA. Therefore, lingual ISDN spray should be preferred over sublingual NTG tablets for CCTA. KEY POINTS: • Lingual ISDN spray was more efficacious than sublingual NTG tablet for coronary vasodilation in coronary CT angiography, even in elderly patients. • The diameters of all coronary segments except RI and L-PDA were significantly larger, and there were significantly more coronary segments greater than 1.5 mm, except RI and L-PDA, in the spray group than in the tablet group in the whole study group. • Even in peripheral and branch vessels, the diameters of coronary arteries were significantly larger in the spray group than in the tablet group, and they were also larger in elderly patients.


Assuntos
Nitratos , Vasodilatação , Administração Sublingual , Idoso , Angiografia por Tomografia Computadorizada , Angiografia Coronária , Vasos Coronários/diagnóstico por imagem , Humanos , Nitroglicerina/farmacologia , Estudos Retrospectivos , Comprimidos
9.
Radiology ; 292(3): 575-582, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31310173

RESUMO

Background Electrophysiology studies have demonstrated that left atrial late gadolinium enhancement (LGE) is associated with the chronicity of atrial fibrillation (AF). To date, cardiac MRI has been used to assess the extent of atrial LGE but not the distribution pattern of LGE in the left atrium. Purpose To determine whether the MRI pattern of left atrial fibrosis is associated with the chronicity of AF. Materials and Methods This retrospective study included patients with AF who underwent LGE MRI between June 2017 and May 2018. The presence of left atrial LGE was assessed at nine left atrial segments; the extent was determined by the number of segments involved. According to the chronicity of AF, patients were separated into paroxysmal AF (PAF) and persistent AF (PeAF) groups. The location and extent of left atrial LGE were compared between PAF and PeAF by using the χ2 test and logistic regression analysis. Results Of the 195 patients (mean age, 55 years ± 10 [standard deviation], 161 men), 74 (38%) had PAF and 121 (62%) had PeAF. Of all patients, 114 (58.4%) had at least one left atrial LGE segment. The mean number of LGE segments was higher (1.4 ± 1.1 vs 0.6 ± 0.7, P = .002) in the PeAF group than in the PAF group. The incidence of LGE at the left inferior pulmonary vein (LIPV) antrum was higher in the PeAF group than in the PAF group (39.2% [29 of 74] vs 7.4% [nine of 121]; P < .001). In multivariable analysis, LGE at the LIPV antrum was independently associated with PeAF (odds ratio = 4.2; 95% confidence interval: 1.7, 10.5; P < .001). Conclusion The presence of fibrosis assessed with late gadolinium enhancement MRI of the left inferior pulmonary vein antrum was associated with persistent atrial fibrillation. © RSNA, 2019 Online supplemental material is available for this article. See also the editorial by Almeida in this issue.


Assuntos
Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/patologia , Meios de Contraste/farmacocinética , Feminino , Fibrose/complicações , Fibrose/diagnóstico por imagem , Fibrose/patologia , Gadolínio/farmacocinética , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/patologia , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem
10.
Radiology ; 284(2): 381-389, 2017 08.
Artigo em Inglês | MEDLINE | ID: mdl-28394753

RESUMO

Purpose To investigate the relationship between left atrial appendage (LAA) blood flow determined with cardiac magnetic resonance (MR) imaging and left atrial pressure (LAP) estimated from invasive catheter measurements in patients with atrial fibrillation (AF). Materials and Methods This retrospective study was approved by the institutional review board, and patients provided written informed consent. Seventy-seven patients with AF (mean age, 57.8 years ± 9.8; range, 31-76 years) underwent cardiac MR imaging and catheter-based measurement of LAP, sequentially. Velocity-encoded (VENC) cardiac MR imaging was performed perpendicular to the ostium of the LAA. The maximum blood flux (in milliliters per second) from the LAA to the left atrium (LA) as determined with VENC MR imaging was defined as LAA emptying. Patients were classified into two groups: those with elevated LAP (peak LAP ≥19 mm Hg) and those with nonelevated LAP (peak LAP <19 mm Hg). Receiver operating characteristic curves were used to determine the cut-off values of LAA emptying in the assessment of the LAP status. Results LAA emptying showed a significantly inverse relationship (P < .01) with the peak LAP. Patients with elevated LAP showed significantly less LAA emptying than did patients with nonelevated LAP (mean, 39.3 mL/sec ± 13.7 vs 61.2 mL/sec ± 20.7, respectively; P < .01). In the assessment of elevated LAP with use of VENC MR imaging in normal sinus rhythm, the LAA emptying cut-off value of 47 mL/sec had a sensitivity of 75.0%, specificity of 87.5%, positive predictive value of 66.6%, and negative predictive value of 91.3%. At multivariate analysis, the odds ratio of low LAA emptying (<47 mL/sec) was independently associated with elevated LAP. Conclusion Evaluation of LAA emptying with use of VENC MR imaging is helpful for assessing the LAP status of patients with AF. © RSNA, 2017.


Assuntos
Apêndice Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Pressão Atrial/fisiologia , Imagem Cinética por Ressonância Magnética/métodos , Idoso , Fibrilação Atrial/cirurgia , Técnicas de Imagem de Sincronização Cardíaca , Ablação por Cateter , Eletrocardiografia , Feminino , Hemodinâmica , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade
11.
Eur Radiol ; 26(9): 3147-54, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26662264

RESUMO

OBJECTIVES: To compare the diagnostic performance of digital tomosynthesis (DTS) and chest radiography for detecting airway abnormalities, using computed tomography (CT) as a reference. MATERIALS AND METHODS: We evaluated 161 data sets from 149 patients (91 with and 70 without airway abnormalities) who had undergone radiography, DTS, and CT to detect airway problems. Radiographs and DTS were evaluated to localize and score the severity of the airway abnormalities, and to score the image quality using CT as a reference. Receiver operating characteristics (ROC), McNemar's test, weighted kappa, and the paired t-test were used for statistical analysis. RESULTS: The sensitivity of DTS was higher (reader 1, 93.51 %; reader 2, 94.29 %) than chest radiography (68.83 %; 71.43 %) in detecting airway lesions. The diagnostic accuracy of DTS (90.91 %; 94.70 %) was also significantly better than that of radiography (78.03 %; 82.58 %, all p < 0.05). DTS image quality was significantly better than chest radiography (1.83, 2.74; p < 0.05) in the results of both readers. The inter-observer agreement with respect to DTS findings was moderate and superior when compared to radiography findings. CONCLUSIONS: DTS is a more accurate and sensitive modality than radiography for detecting airway lesions that are easily obscured by soft tissue structures in the mediastinum. KEY POINTS: • Digital tomosynthesis offers new diagnostic options for airway lesions. • Digital tomosynthesis is more sensitive and accurate than radiography for airway lesions. • Digital tomosynthesis shows better image quality than radiography. • Assessment of lesion severity, via tomosynthesis is comparable to computed tomography.


Assuntos
Pneumopatias/diagnóstico , Intensificação de Imagem Radiográfica/métodos , Radiografia Torácica/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Curva ROC
12.
J Comput Assist Tomogr ; 38(4): 597-603, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24651745

RESUMO

OBJECTIVE: To investigate the relationship between a chronic obstructive pulmonary disease (COPD) candidate gene, based on a genomewide association study, and computed tomographic (CT) quantitative analysis; and to find a phenotype in the COPD candidate FAM13A gene. MATERIALS AND METHODS: This study was conducted in subclinical male smokers between 2 groups with matched age and smoking status; 162 subjects (mean age, 58 years) with risk (CTGA, n = 85) and reference (TCAG, n = 77) diplotypes replicated through genomewide association study underwent chest CT for quantitative analysis of lungs and airways. We analyzed the measures in both the risk and reference groups using a 2-sample t test. RESULTS: Subjects with the risk CTGA diplotype had significantly higher total lung volume and emphysema index than the reference TCAG diplotype (P = 0.04). Mean lung density was significantly lower (P < 0.05) in the risk group. However, in the analysis of airways, wall area, luminal area, wall and lumen area ratio, and mean lung density on expiratory and inspiratory phases, no significant differences between the 2 groups were seen. CONCLUSIONS: There is a strong relationship between CT quantitative analysis and the COPD candidate gene. Furthermore, the CTGA diplotype was associated with emphysema among the phenotypes of COPD.


Assuntos
Proteínas Ativadoras de GTPase/genética , Predisposição Genética para Doença/genética , Doença Pulmonar Obstrutiva Crônica/diagnóstico por imagem , Doença Pulmonar Obstrutiva Crônica/genética , Tomografia Computadorizada por Raios X/métodos , Idoso , Estudos de Casos e Controles , Humanos , Pulmão/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Testes de Função Respiratória/métodos , Testes de Função Respiratória/estatística & dados numéricos , Fatores de Risco , Fumar
13.
J Korean Soc Radiol ; 85(2): 297-307, 2024 Mar.
Artigo em Coreano | MEDLINE | ID: mdl-38617850

RESUMO

Coronary artery disease (CAD) narrows vessel lumens at the sites of atherosclerosis, increasing the risk of myocardial ischemia or infarction. Early and accurate diagnosis of CAD is crucial to significantly improve prognosis and management. CT angiography (CTA) is a noninvasive imaging technique that enables assessment of vascular structure and stenosis with high resolution and contrast. Coronary CTA is useful in the diagnosis of CAD. Recently, the CAD-reporting and data system (CAD-RADS), a diagnostic classification system based on coronary CTA, has been developed to improve intervention efficacy in patients suspected of CAD. While the CAD-RAD is based on CTA, it includes borderline categories where interpreting the coronary artery status solely based on CTA findings may be challenging. This review introduces CTA findings that fall within the CAD-RADS categories that necessitate additional tests to decide to perform invasive coronary angiography and discusses appropriate management strategies.

14.
J Korean Soc Radiol ; 84(1): 298-303, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36818711

RESUMO

Electronic cigarette or vaping-associated lung injury (EVALI) is a disease defined by lung injuries caused by e-cigarette use. It predominantly manifests in forms of organized pneumonia or diffuse alveolar damage but rarely as acute eosinophilic pneumonia (AEP). This report describes a 34-year-old male with acute respiratory symptoms and a vaping history of only nicotine. Chest CT revealed peripheral distributing multiple patchy consolidations and ground-glass opacities dominant in both lower lobes, bilateral diffuse interlobular septal thickening, and bilateral pleural effusion without cardiomegaly. Bronchoalveolar lavage fluids showed increased eosinophilia levels, while infectious laboratory results were all negative, enabling the diagnosis of both AEP and EVALI. Herein, we report a rare case of only-nicotine vaping EVALI manifested as AEP.

15.
Eur Radiol ; 22(8): 1812-9, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22466514

RESUMO

OBJECTIVES: To evaluate the incremental value of diffusion-weighted imaging (DWI) in combination with T2-weighted imaging to detect low (Gleason score, ≤ 6) and intermediate or high risk (Gleason score, ≥ 7) prostate cancer. METHODS: Fifty-one patients who underwent MRI before prostatectomy were evaluated. Two readers independently scored the probability of tumour in eight regions of prostate on T2-weighted images (T2WI) and T2WI combined with apparent diffusion coefficient (ADC) maps. Data were divided into two groups--low risk and intermediate or high risk prostate cancer--and correlated with histopathological results. Diagnostic performance parameters, areas under the receiver-operating characteristic curve (AUCs) and interreader agreement were calculated. RESULTS: For both readers, AUCs of combined T2WI and ADC maps were greater than those of T2WI in intermediate or high risk (reader 1, 0.887 vs. 0.859; reader 2, 0.732 vs 0.662, P < 0.05) prostate cancers, but not in low risk (reader 1, 0.719 vs 0.725; reader 2, 0.685 vs. 0.680, P > 0.05) prostate cancers. Weighted κ value of combined T2WI and ADC maps was 0.689. CONCLUSIONS: The addition of DWI to T2-weighted imaging improves the accuracy of detecting intermediate or high risk prostate cancers, but not for low risk prostate cancer detection. KEY POINTS: • Gleason scores influence diagnostic performance of MRI for prostate cancer detection. • Addition of DWI does not improve low risk prostate cancer detection. • Combined T2WI and DWI may help select intermediate or high risk patients.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Neoplasias da Próstata/diagnóstico , Neoplasias da Próstata/patologia , Idoso , Área Sob a Curva , Difusão , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Oncologia/métodos , Pessoa de Meia-Idade , Gradação de Tumores , Próstata/patologia , Prostatectomia/métodos , Curva ROC , Estudos Retrospectivos , Risco , Sensibilidade e Especificidade
16.
J Comput Assist Tomogr ; 36(5): 528-33, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22992601

RESUMO

RATIONALE AND OBJECTIVES: We investigated the relationships between spontaneously healed asymptomatic pulmonary tuberculosis (SHAPTB), airflow obstruction (AFO), and high-resolution computed tomography (HRCT) findings. MATERIALS AND METHODS: We selected 82 participants with SHAPTB diagnosed by interferon-γ release assay and 8044 with normal chest radiographs (CXR). We applied a CT scoring system for the extent of tuberculous sequelae to correlate the HRCT findings with pulmonary function test. We compared the AFO prevalence between subjects with and without SHAPTB. RESULTS: The subjects with SHAPTB diagnosed by interferon-γ release assay had a significantly higher prevalence of AFO (13.4% [11/82]) than those with normal CXR (7.4% [595/8044]). The important HRCT findings that correlated with AFO were the number of lung segments with TB sequelae and the CT score for emphysema. CONCLUSION: The subjects with SHAPTB had a higher AFO prevalence than those with normal CXR, and the important HRCT findings correlated with AFO were the extent of tuberculous sequelae and emphysema.


Assuntos
Obstrução das Vias Respiratórias/diagnóstico por imagem , Obstrução das Vias Respiratórias/epidemiologia , Obstrução das Vias Respiratórias/fisiopatologia , Tomografia Computadorizada por Raios X/métodos , Tuberculose Pulmonar/diagnóstico por imagem , Tuberculose Pulmonar/fisiopatologia , Adulto , Idoso , Distribuição de Qui-Quadrado , Feminino , Humanos , Testes de Liberação de Interferon-gama , Masculino , Pessoa de Meia-Idade , Prevalência , Estudos Prospectivos , Interpretação de Imagem Radiográfica Assistida por Computador , Radiografia Torácica , Remissão Espontânea , Testes de Função Respiratória
17.
Skeletal Radiol ; 41(10): 1301-8, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22430562

RESUMO

OBJECTIVE: To determine the relationship between clinical impairment and MRI findings in patients with adhesive capsulitis. MATERIALS AND METHODS: Contrast-enhanced MRI of 97 patients with a clinical diagnosis of adhesive capsulitis (AC) were retrospectively reviewed. Specific MRI criteria, including thickness and gadolinium enhancement of the joint capsule in the axillary recess and subcoracoid fat obliteration in the rotator interval, were correlated with limited range of motion (ROM) and pain. Other variables considered in this study were rotator cuff pathology, arm dominance, diabetes mellitus, age, and gender. Statistical analysis was performed using logistic and linear regression analysis. RESULTS: Thickening of the joint capsule in the axillary recess correlated with limited external rotation (p < 0.01), gender (p < 0.01) and arm dominance (p < 0.05). Gadolinium enhancement of the joint capsule in the axillary recess correlated with pain intensity (p < 0.05). Subcoracoid fat obliteration in the rotator interval was not correlated with limited ROM or pain. CONCLUSIONS: MRI can be a useful technique to assess several clinical impairment measures in patients with adhesive capsulitis. Thickening and gadolinium enhancement of the joint capsule in the axillary recess on MRI are associated with limited ROM and pain.


Assuntos
Bursite/diagnóstico , Imageamento por Ressonância Magnética/métodos , Amplitude de Movimento Articular , Articulação do Ombro/patologia , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Estatística como Assunto
18.
ScientificWorldJournal ; 2012: 835031, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22666158

RESUMO

Tuberculous destroyed lung (TDL) is diagnosed by a clear past history of tuberculosis with findings of parenchymal destruction verified by chest X-ray. Despite the resultant deterioration of lung function and quality of lives seen in TDL patients, the exact mechanism or characteristics of pulmonary function worsening have not been clearly studied. We investigated the feature of respiratory impairment of TDL patients, and studied whether extent of destroyed lung measured with chest CT has any correlation with routine lung function. To evaluate the degree of destruction, the Goddard classification scoring system was modified into a novel scoring system (destroyed lung score, (DLS)) with a score from 0 to 4. Twenty-five subjects were enrolled. TDL predominantly manifested as an obstructive pattern (64%, 16/25). Median value of DLS of the entire lung was 2.6 (1.7-3.9). Absolute values of FEV1 and FVC were both negatively associated with DLS (r = -0.78, P = 0.001, and r = -0.61, P = 0.021). Percentage of predicted value of FEV1 and FVC were also negatively associated with DLS (r = -0.62, P = 0.019, and r = -0.76, P = 0.002). Our study shows that lung function of TDL patients were notably correlated with the extent of destroyed lung measured with chest CT scan.


Assuntos
Testes de Função Respiratória , Tuberculose Pulmonar/patologia , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
19.
J Ultrasound Med ; 30(1): 3-10, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21193699

RESUMO

OBJECTIVES: The aim of study was to assess the usefulness of 3D ultrasonography (3DUS) in the diagnosis of carpal tunnel syndrome. METHODS: Fifty patients with carpal tunnel syndrome confirmed by electromyography and 37 healthy control participants underwent 3DUS of the wrists. The mean times per participant for the 3DUS examination and review of the 3D volume set were recorded. The cross-sectional area at the proximal carpal tunnel and the maximum swelling point were measured. Data from patients and controls were compared for determination of statistical significance. The accuracy of the 3DUS diagnostic criteria for carpal tunnel syndrome was evaluated using receiver operating characteristic analysis, and changes in the median nerve shape, including the maximum swelling point, were assessed by review of the 3D volume data. RESULTS: The mean times for examination of a participant and review in each wrist were 56 seconds and 5.7 minutes, respectively. Significant differences were observed in the mean cross-sectional areas of the median nerve between patients and controls. The mean cross-sectional areas ± SD were 16.7 ± 6.7 mm(2) in patients and 8.3 ± 1.9 mm(2) in controls. Using the receiver operating characteristic curve, a cutoff value of greater than 10.5 mm(2) provided diagnostic sensitivity of 84% and specificity of 86%. In 42 of 73 wrists with carpal tunnel syndrome, the median nerve showed fusiform morphologic abnormalities and maximum swelling points. CONCLUSIONS: Our results show that 3DUS could markedly decrease scanning time, and measurement of the median nerve cross-sectional area combined with morphologic analysis using 3DUS is a promising supplementary method for the diagnosis of carpal tunnel syndrome.


Assuntos
Síndrome do Túnel Carpal/diagnóstico por imagem , Imageamento Tridimensional/métodos , Adulto , Idoso , Feminino , Humanos , Masculino , Nervo Mediano/diagnóstico por imagem , Pessoa de Meia-Idade , Curva ROC , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Ultrassonografia , Articulação do Punho/diagnóstico por imagem
20.
Taehan Yongsang Uihakhoe Chi ; 82(6): 1545-1555, 2021 Nov.
Artigo em Coreano | MEDLINE | ID: mdl-36238883

RESUMO

Purpose: The purpose of this study was to evaluate the rates of unacceptable diagnosis and clinically significant diagnostic discrepancy in radiology sections and imaging modalities through a peer review of teleradiology. Materials and Methods: Teleradiology peer reviews in a Korean teleradiology clinic in 2018 and 2019 were included. The peer review scores were classified as acceptable and unacceptable diagnoses and clinically insignificant and significant diagnostic discrepancy. The diagnostic discrepancy rates and clinical significance were compared among radiology sections and imaging modalities using the chi-square test. Results: Of 1312 peer reviews, 117 (8.9%) cases had unacceptable diagnoses. Of 462 diagnostic discrepancies, the clinically significant discrepancy was observed in 104 (21.6%) cases. In radiology sections, the unacceptable diagnosis was highest in the musculoskeletal section (21.4%) (p < 0.05), followed by the abdominal section (7.3%) and neuro section (1.3%) (p < 0.05). The proportion of significant discrepancy was higher in the chest section (32.7%) than in the musculoskeletal (19.5%) and abdominal sections (17.1%) (p < 0.05). Regarding modalities, the number of unacceptable diagnoses was higher with MRI (16.2%) than plain radiology (7.8%) (p < 0.05). There was no significant difference in significant discrepancy. Conclusion: Peer review provides the rates of unacceptable diagnosis and clinically significant discrepancy in teleradiology. These rates also differ with subspecialty and modality.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA