1.
Water Res ; 139: 132-143, 2018 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-29635150

RESUMO

Modern Water Distribution Systems (WDSs) are often controlled by Supervisory Control and Data Acquisition (SCADA) systems and Programmable Logic Controllers (PLCs) which manage their operation and maintain a reliable water supply. As such, and with the cyber layer becoming a central component of WDS operations, these systems are at a greater risk of being subjected to cyberattacks. This paper offers a model-based methodology based on a detailed hydraulic understanding of WDSs combined with an anomaly detection algorithm for the identification of complex cyberattacks that cannot be fully identified by hydraulically based rules alone. The results show that the proposed algorithm is capable of achieving the best-known performance when tested on the data published in the BATtle of the Attack Detection ALgorithms (BATADAL) competition (http://www.batadal.net).


Assuntos
Segurança Computacional , Modelos Teóricos , Abastecimento de Água , Algoritmos
2.
Water Res ; 110: 180-191, 2017 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-28006708

RESUMO

The Fault Detection (FD) Problem in control theory concerns of monitoring a system to identify when a fault has occurred. Two approaches can be distinguished for the FD: Signal processing based FD and Model-based FD. The former concerns of developing algorithms to directly infer faults from sensors' readings, while the latter uses a simulation model of the real-system to analyze the discrepancy between sensors' readings and expected values from the simulation model. Most contamination Event Detection Systems (EDSs) for water distribution systems have followed the signal processing based FD, which relies on analyzing the signals from monitoring stations independently of each other, rather than evaluating all stations simultaneously within an integrated network. In this study, we show that a model-based EDS which utilizes a physically based water quality and hydraulics simulation models, can outperform the signal processing based EDS. We also show that the model-based EDS can facilitate the development of a Multi-Site EDS (MSEDS), which analyzes the data from all the monitoring stations simultaneously within an integrated network. The advantage of the joint analysis in the MSEDS is expressed by increased detection accuracy (higher true positive alarms and fewer false alarms) and shorter detection time.


Assuntos
Modelos Teóricos , Qualidade da Água , Algoritmos
3.
Water Res ; 73: 193-203, 2015 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-25662513

RESUMO

Placement of water quality sensors in a water distribution system is a common approach for minimizing contamination intrusion risks. This study incorporates detailed chemistry of organophosphate contaminations into the problem of sensor placement and links quantitative measures of the affected population as a result of such intrusions. The suggested methodology utilizes the stoichiometry and kinetics of the reactions between organophosphate contaminants and free chlorine for predicting the number of affected consumers. This is accomplished through linking a multi-species water quality model and a statistical dose-response model. Three organophosphates (chlorpyrifos, malathion, and parathion) are tested as possible contaminants. Their corresponding by-products were modeled and accounted for in the affected consumers impact calculations. The methodology incorporates a series of randomly generated intrusion events linked to a genetic algorithm for minimizing the contaminants impact through a sensors system. Three example applications are explored for demonstrating the model capabilities through base runs and sensitivity analyses.


Assuntos
Monitoramento Ambiental/métodos , Poluentes Químicos da Água/análise , Qualidade da Água , Clorpirifos/análise , Monitoramento Ambiental/instrumentação , Inseticidas/análise , Malation/análise , Modelos Teóricos , Paration/análise , Reprodutibilidade dos Testes , Abastecimento de Água
4.
Water Res ; 58: 209-20, 2014 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-24762553

RESUMO

This study describes a new methodology for the disinfection booster design, placement, and operation problem in water distribution systems. Disinfectant residuals, which are in most cases chlorine residuals, are assumed to be sufficient to prevent growth of pathogenic bacteria, yet low enough to avoid taste and odor problems. Commonly, large quantities of disinfectants are released at the sources outlets for preserving minimum residual disinfectant concentrations throughout the network. Such an approach can cause taste and odor problems near the disinfectant injection locations, but more important hazardous excessive disinfectant by-product formations (DBPs) at the far network ends, of which some may be carcinogenic. To cope with these deficiencies booster chlorination stations were suggested to be placed at the distribution system itself and not just at the sources, motivating considerable research in recent years on placement, design, and operation of booster chlorination stations in water distribution systems. The model formulated and solved herein is aimed at setting the required chlorination dose of the boosters for delivering water at acceptable residual chlorine and TTHM concentrations for minimizing the overall cost of booster placement, construction, and operation under extended period hydraulic simulation conditions through utilizing a multi-species approach. The developed methodology links a genetic algorithm with EPANET-MSX, and is demonstrated through base runs and sensitivity analyses on a network example application. Two approaches are suggested for dealing with water quality initial conditions and species periodicity: (1) repetitive cyclical simulation (RCS), and (2) cyclical constrained species (CCS). RCS was found to be more robust but with longer computational time.


Assuntos
Desinfecção/métodos , Modelos Teóricos , Trialometanos/análise , Purificação da Água/métodos , Algoritmos , Desinfecção/instrumentação , Desenho de Equipamento , Halogenação , Purificação da Água/instrumentação