Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Dement Geriatr Cogn Disord ; 27(2): 133-8, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19182480

RESUMO

BACKGROUND/AIMS: The frontal assessment battery (FAB) is reported to be a useful tool for screening frontal function. However, the neural substrates involved remain to be elucidated. The aim of the present study was to identify the brain regions responsible for FAB performance in patients with early dementia. We sought a correlation between FAB scores and brain perfusion. METHODS: A total of 117 subjects participated in this study (Alzheimer's disease = 51, frontotemporal dementia = 14, vascular dementia = 13, dementia with Lewy bodies = 7, psychiatric disease = 7, mild cognitive impairment = 11, controls = 14). They underwent brain single photon emission computed tomography with (99m)Tc-ethylcisteinate dimer, and we analyzed the data, using a regional cerebral blood flow (rCBF) quantification software program, 3DSRT (3-dimensional stereotaxic region of interest template). RESULTS: FAB scores had a moderately positive correlation with left callosomarginal and precentral rCBF. Comparison of rCBF between high- and low-scoring FAB groups revealed that the latter showed significantly lower rCBF in the bilateral callosomarginal and left precentral regions. CONCLUSION: The results in this study suggest that the FAB mainly reflects the function of the callosomarginal and precentral segments, especially the left side, and that it might be a valid frontal lobe function test.


Assuntos
Circulação Cerebrovascular/fisiologia , Demência/fisiopatologia , Córtex Pré-Frontal/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Doença de Alzheimer/diagnóstico por imagem , Doença de Alzheimer/fisiopatologia , Doença de Alzheimer/psicologia , Demência/diagnóstico por imagem , Educação , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Testes Neuropsicológicos , Córtex Pré-Frontal/diagnóstico por imagem , Tomografia Computadorizada de Emissão de Fóton Único
2.
Sleep ; 26(2): 169-72, 2003 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-12683476

RESUMO

STUDY OBJECTIVES: The positional dependency of obstructive sleep apnea (OSA) is well known, but objective evidence for the positional effect on snoring is lacking. The aim of this study is to elucidate the effect of body position on snoring, and that of sleep stage as well. DESIGN: Retrospective analysis of the effects of body position and sleep stage on snoring in nonapneic snorers (snorer group) and OSA patients (apneic group). SETTING: A sleep laboratory in a national hospital in Japan. PATIENTS: Seventy-two patients who complained of habitual snoring and underwent overnight polysomnography. INTERVENTIONS: N/A. MEASUREMENTS AND RESULTS: In the lateral position, most subjects in the snorer group showed decreased snoring both in time (p = 0.0004) and intensity (p = 0.0003), but subjects in the apneic group showed variable changes. In the apneic group, the positional dependency of snoring (the ratio of lateral value to supine value) was correlated with supine apnea-hypopnea index (AHI), that is, OSA patients with higher supine AHI tended to show increased snoring in the lateral position. AS to the effect of sleep stage, snoring was increased in deeper non-rapid eye movement sleep and decreased in rapid eye movement sleep in a given position. CONCLUSIONS: This study demonstrated that the positional dependency is different between nonapneic snorers and OSA patients. Most of the nonapneic snorers snore less in the lateral position than in the supine position in contrast to OSA patients who often fail to decrease snoring even in the lateral position.


Assuntos
Postura , Apneia Obstrutiva do Sono/complicações , Ronco/etiologia , Acústica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Polissonografia , Estudos Retrospectivos , Índice de Gravidade de Doença , Apneia Obstrutiva do Sono/diagnóstico , Fases do Sono/fisiologia , Ronco/diagnóstico
3.
Sleep ; 27(5): 951-7, 2004 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-15453554

RESUMO

STUDY OBJECTIVES: To evaluate the validity of a novel method of using tracheal sound analysis for the diagnosis of sleep apnea-hypopnea syndrome. DESIGN: Retrospective analysis in consecutive patients. SETTING: A sleep clinic in a general hospital. PATIENTS: A total of 383 patients who were referred for suspected sleep apnea-hypopnea syndrome and underwent diagnostic polysomnography with sufficient quality. INTERVENTIONS: N/A. MEASUREMENTS AND RESULTS: Ordinary polysomnography with simultaneous tracheal sound recording was performed. The apnea-hypopnea index (AHI) was calculated as the number of apnea and hypopnea events per hour of sleep. Tracheal sounds were digitized and recorded as power spectra. An automated computer program detected transient falls (TS-dip) in the time series of moving average of the logarithmic power of tracheal sound. We defined the tracheal sound-respiratory disturbance index (TS-RDI) as the number of TS-dips per hour of examination. We also calculated the oxygen desaturation index (the number of SaO2 dips of at least 4% per hour of examination). The TS-RDI highly correlated with AHI (r = 0.93). The mean (+/- SD) difference between the TS-RDI and AHI was -8.4 +/- 10.4. The diagnostic sensitivity and specificity of the TS-RDI when the same cutoff value was used as for AHI were 93% and 67% for the AHI cutoff value of 5 and 79% and 95% for the AHI cutoff value of 15. The agreement between the TS-RDI and AHI was better than that between the oxygen desaturation index and AHI. CONCLUSIONS: The fully automated tracheal sound analysis demonstrated a relatively high performance in the diagnosis of sleep apnea-hypopnea syndrome. We think that this method is useful for the portable monitoring of sleep apnea-hypopnea syndrome.


Assuntos
Monitorização Fisiológica/instrumentação , Síndromes da Apneia do Sono/diagnóstico , Som , Traqueia/fisiologia , Adulto , Algoritmos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Polissonografia , Estudos Retrospectivos , Índice de Gravidade de Doença , Fases do Sono/fisiologia , Espectrografia do Som/instrumentação
4.
Respir Med ; 98(5): 421-7, 2004 May.
Artigo em Inglês | MEDLINE | ID: mdl-15139571

RESUMO

Overnight oximetry is widely used for screening for the sleep apnea hypopnea syndrome (SAHS). The degree of desaturation at an apnea event is known to be affected by the degree of obesity. We hypothesized that the diagnostic ability of oximetry for SAHS is affected by the degree of obesity. A total of 424 consecutive patients referred for possible SAHS were studied. The subjects were classified into three groups of normal-weight, overweight and obese based on the body mass index (BMI). The apnea-hypopnea index (> or = 15 h(-1)) by polysomnography was used as the diagnostic gold standard. Oximetry data were automatically analyzed to calculate the oxygen desaturation index (ODI2/3/4:at 2%/3%/4% threshold). The diagnostic abilities of the ODI were different in the three BMI-groups at a given cutoff value, e.g. the sensitivity/specificity of ODI4 (cutoff = 15) were 54%/100%, 83%/ 97%, and 98%/78% for the normal-weight, overweight and obese groups, respectively (P < 0.0001). The gender and the age had no significant effect on the ability. We demonstrated the diagnostic sensitivity and specificity of the ODI for SAHS depended on the BMI. Oximetry as a screening tool for SAHS may become more useful by selection of a cutoff value appropriate for the BMI of each subject.


Assuntos
Índice de Massa Corporal , Obesidade/complicações , Síndromes da Apneia do Sono/diagnóstico , Idoso , Análise de Variância , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Oximetria/métodos , Polissonografia , Curva ROC , Estudos Retrospectivos , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA