Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 46
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Vasc Interv Radiol ; 33(3): 304-307, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35221047

RESUMO

The utility of occluding the bleeding artery using an occlusion balloon catheter during stent-graft placement for visceral artery bleeding was evaluated. Stent-graft placement for visceral artery bleeding was performed using a balloon catheter in 6 patients. All bleeding occurred after biliary or pancreatic surgery. Since 1 patient underwent the procedure twice, 7 procedures were assessed in total. Technical success, procedure-related adverse events, and 30-day mortality rates were evaluated. Technical success was defined as the placement of the stent-graft at the target site and the resolution of extravasation or pseudoaneurysm. In all procedures, stent-graft placement was successfully performed (technical success rate, 100%). Focal liver infarction occurred in 2 of 7 patients (29%), but did not require further treatment and was considered a minor adverse event. The 30-day mortality rate was 0%. In conclusion, the use of an occlusion balloon in the feeding artery facilitated successful stent-graft repair of hemorrhage from visceral arteries.


Assuntos
Implante de Prótese Vascular , Stents , Artérias , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/métodos , Catéteres , Hemorragia/diagnóstico por imagem , Hemorragia/etiologia , Hemorragia/terapia , Humanos , Estudos Retrospectivos , Resultado do Tratamento
2.
J Vasc Interv Radiol ; 33(11): 1329-1334, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36511304

RESUMO

This study evaluated the utility of carbon dioxide (CO2) in angiography for the detection of lower gastrointestinal arterial bleeding initially occult to angiography with iodinated contrast media. Fourteen patients underwent CO2-enhanced angiography. In all patients, extravasation was identified by contrast-enhanced computed tomography but not by initial iodinated contrast-enhanced angiography. After iodinated contrast-enhanced angiography, CO2-enhanced angiography was performed from the same catheter position. The detection capability for extravasation on CO2-enhanced angiography was evaluated. CO2-enhanced angiography allowed for the visualization of extravasation and subsequent transcatheter arterial embolization in 11 of 14 (79%) cases, with extravasation seen during either CO2-enhanced angiography (n = 8) or subsequent repeat iodinated contrast-enhanced angiography immediately after negative CO2-enhanced angiography (n = 3). Conservative treatment was performed in the remaining 3 cases. In conclusion, CO2-enhanced angiography appears useful for identifying occult lower gastrointestinal bleeding.


Assuntos
Angiografia , Dióxido de Carbono , Humanos , Dióxido de Carbono/efeitos adversos , Angiografia/efeitos adversos , Angiografia/métodos , Meios de Contraste/efeitos adversos , Artérias , Hemorragia Gastrointestinal/induzido quimicamente , Hemorragia Gastrointestinal/diagnóstico por imagem
3.
Minim Invasive Ther Allied Technol ; 31(3): 389-395, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33140983

RESUMO

PURPOSE: The aim of this study was to evaluate the usefulness of transcatheter arterial embolization (TAE) using the triaxial system with N-butyl-2-cyanoacrylate (NBCA) for acute arterial bleeding in comparison to TAE using the triaxial system with gelatin sponges (GS) and/or coils. MATERIAL AND METHODS: Between October 2013 and November 2018, 95 patients with acute arterial bleeding underwent emergency TAE using the triaxial system. Six patients underwent multiple TAEs and thus, 104 TAEs using the triaxial system were performed. In 26 of the 104 cases, TAE were performed with NBCA (NBCA group), and in the remaining 78 cases, TAE were performed with GS and/or coils (control group). RESULTS: Hemorrhagic shock and coagulopathy more often occurred in the NBCA group. Procedure time was shorter in the NBCA group. The technical success rate was 100% in both groups (p > 0.99). The clinical success rate in the NBCA and control groups was 92% and 96%, respectively (p = 0.6). There was one minor complication (4%, 1/26) of liver dysfunction in a patient of the NBCA group, but no complication in the control group (p = 0.26). CONCLUSION: TAE using the triaxial system with NBCA may be useful for acute arterial bleeding, especially in patients with hemorrhagic shock and coagulopathy.


Assuntos
Embolização Terapêutica , Embucrilato , Embolização Terapêutica/métodos , Embucrilato/uso terapêutico , Humanos , Estudos Retrospectivos , Resultado do Tratamento
4.
Jpn J Clin Oncol ; 51(2): 258-263, 2021 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-33029639

RESUMO

BACKGROUND: To compare the feasibility of transrectal and transperineal fiducial marker placement for prostate cancer before proton therapy. MATERIALS AND METHODS: From 2013 to 2015, the first 40 prostate cancer patients that were scheduled for proton therapy underwent transrectal fiducial marker placement, and the next 40 patients underwent transperineal fiducial marker placement (the first series). Technical and clinical success and pain scores were evaluated. In the second series (n = 280), the transrectal or transperineal approach was selected depending on the presence/absence of comorbidities, such as blood coagulation abnormalities. Seven patients refused to undergo the procedure. Thus, the total number of patients across both series was 353 (262 and 91 underwent the transrectal and transperineal approach, respectively). Technical and clinical success, complications, marker migration and the distance between the two markers were evaluated. RESULTS: In the first series, the technical and clinical success rates were 100% in both groups. The transrectal group exhibited lower pain scores than the transperineal group. The overall technical success rates of the transrectal and transperineal groups were 100% (262/262) and 99% (90/91), respectively (P > 0.05). The overall clinical success rate was 100% in both groups, and there were no major complications in either group. The migration rates of the two groups did not differ significantly. The mean distance between the two markers was 25.6 ± 7.1 mm (mean ± standard deviation) in the transrectal group and 31.9 ± 5.2 mm in the transperineal group (P < 0.05). CONCLUSION: Both the transrectal and transperineal fiducial marker placement methods are feasible and safe.


Assuntos
Marcadores Fiduciais , Períneo/patologia , Neoplasias da Próstata/terapia , Terapia com Prótons , Reto/patologia , Idoso , Idoso de 80 Anos ou mais , Estudos de Viabilidade , Humanos , Masculino , Pessoa de Meia-Idade , Períneo/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Reto/diagnóstico por imagem
5.
J Endovasc Ther ; 27(5): 828-835, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32436809

RESUMO

PURPOSE: To evaluate the feasibility and safety of sac embolization with N-butyl cyanoacrylate (NBCA) in emergency endovascular aneurysm repair (EVAR) for ruptured abdominal aortic aneurysm (AAA) and iliac artery aneurysm (IAA) in comparison to EVAR without sac embolization. MATERIALS AND METHODS: Between February 2012 and December 2019, among 44 consecutive patients with ruptured AAA or IAA, 29 underwent EVAR. Of these, 22 patients (median age 77.5 years; 18 men) had concomitant sac embolization using NBCA; the remaining 7 patients (median age 88 years; 6 men) underwent EVAR without sac embolization and form the control group. The technical success, clinical success (hemodynamic stabilization), procedure-related complications, and mortality were compared between the groups. RESULTS: All EVAR procedures and embolizations were successful. The clinical success rates in the NBCA and control groups were 95% (21/22) and 71% (5/7), respectively (p=0.14). There was no complication related to the procedure. Type II endoleak occurred in 4 of 21 patients (19%) in the NBCA group vs none of the control patients. One patient (5%) died in the NBCA group vs 3 (43%) in the controls (p=0.034). CONCLUSION: Sac embolization using NBCA in emergency EVAR appears to be feasible and safe for ruptured AAA and IAA.


Assuntos
Aneurisma da Aorta Abdominal/terapia , Ruptura Aórtica/terapia , Implante de Prótese Vascular , Embolização Terapêutica , Embucrilato/administração & dosagem , Procedimentos Endovasculares , Aneurisma Ilíaco/terapia , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/fisiopatologia , Ruptura Aórtica/diagnóstico por imagem , Ruptura Aórtica/fisiopatologia , Implante de Prótese Vascular/efeitos adversos , Embolização Terapêutica/efeitos adversos , Emergências , Embucrilato/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Estudos de Viabilidade , Feminino , Humanos , Aneurisma Ilíaco/diagnóstico por imagem , Aneurisma Ilíaco/fisiopatologia , Masculino , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
6.
Minim Invasive Ther Allied Technol ; 29(3): 140-145, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31012764

RESUMO

Purpose: A steerable triaxial system consisting of a small microcatheter, a high-flow steerable microcatheter, and a 4-Fr. catheter is currently used in clinical settings. The purpose of the present study was to evaluate the efficacy and safety of the steerable triaxial system for challenging catheterization.Material and methods: Sixteen patients underwent an interventional procedure with the steerable triaxial system. Medical records and images of the procedures were reviewed, and the technical success rate, clinical success rate, and complications related to the procedures were evaluated. Technical success was defined as successful catheterization to the target artery using the steerable triaxial system, and clinical success as completion of the aimed procedure.Results: Catheterization to the target artery was successfully performed with the steerable triaxial system in 14 out of 16 patients, but was unsuccessful in two. Therefore, the technical success rate was 88% (14/16). The procedure was successfully accomplished in the 14 technical success patients. Thus, the clinical success rate was 88% (14/16). There were no complications related to the procedures.Conclusions: The steerable triaxial system has potential as a useful and safe technique for challenging catheterization.


Assuntos
Angiografia/instrumentação , Angiografia/métodos , Cateterismo/instrumentação , Cateterismo/métodos , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Catéteres , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
7.
Emerg Radiol ; 26(5): 501-506, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31129737

RESUMO

PURPOSE: To evaluate the clinical outcomes of bronchial artery embolization (BAE) using a gelatin sponge for hemoptysis from pulmonary aspergilloma and compare them with treatment outcomes for hemoptysis from other diseases. METHODS: Fifty-two patients underwent BAE using a gelatin sponge. The etiology of hemoptysis was pulmonary aspergilloma in 8 (PA group) and other diseases in 44 (control group). The technical success rate, clinical success rate, hemoptysis-free rate, and complication rate were compared between the PA group and control group. Technical success was defined as the complete cessation of the targeted feeding artery as confirmed by digital subtraction angiography, and clinical success as the cessation of hemoptysis within 24 h of BAE. Recurrent hemoptysis was defined as a single or multiple episodes of hemoptysis causing > 30 ml of bleeding per day. RESULTS: Technical and clinical success rates were 100% in both groups. Hemoptysis-free rates were 85% at 6 months and 72% at 12-60 months in the control group, and 38% at 6-12 months and 25% thereafter in the PA group (P = 0.0009). No complications were observed following BAE in any case in the two groups. CONCLUSION: BAE using a gelatin sponge may not be effective for hemoptysis from pulmonary aspergilloma.


Assuntos
Artérias Brônquicas , Embolização Terapêutica/métodos , Esponja de Gelatina Absorvível/uso terapêutico , Hemoptise/microbiologia , Hemoptise/terapia , Aspergilose Pulmonar/complicações , Adulto , Idoso , Idoso de 80 Anos ou mais , Angiografia Digital , Feminino , Hemoptise/diagnóstico por imagem , Humanos , Pneumopatias/complicações , Masculino , Pessoa de Meia-Idade , Aspergilose Pulmonar/diagnóstico por imagem , Estudos Retrospectivos
8.
Minim Invasive Ther Allied Technol ; 28(4): 206-212, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30261785

RESUMO

Purpose: To evaluate the usefulness of preoperative transcatheter arterial embolization using a gelatin sponge for hypervascular head and neck tumors to reduce intraoperative blood loss (IBL).     Material and methods: Nineteen patients underwent preoperative transcatheter arterial embolization for hypervascular head and neck tumors using a gelatin sponge. The technical success rate, devascularization rate, IBL, and complications were evaluated. Angiography images obtained before and after preoperative embolization were compared in all patients, and the devascularization rate was assessed from the relative reduction rate of contrast agent volumes. Results: The technical success rate was 100%. The median devascularization rate was 95% (range, 75-100%). The median period between embolization and surgical resection was one day (range, 1-12 days). The median IBL was 122 ml (range, 0-3780 ml). Blood transfusions were required in three cases, and their IBL and devascularization rates were 850, 1959, and 3780 ml, and 75%, 90%, and 80%, respectively. There was a complication of cerebral embolism in one out of 19 cases (5%). Conclusions: Preoperative transcatheter arterial embolization using a gelatin sponge was feasible and may contribute to decreasing IBL.


Assuntos
Perda Sanguínea Cirúrgica/prevenção & controle , Cateterismo Periférico/métodos , Embolização Terapêutica/métodos , Gelatina , Neoplasias de Cabeça e Pescoço/cirurgia , Poríferos , Cuidados Pré-Operatórios/métodos , Adulto , Idoso , Animais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
9.
Minim Invasive Ther Allied Technol ; 27(1): 11-16, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29126350

RESUMO

Recent advances have been made in the development of microcatheters, and have contributed to super-selective catheterization. One new tool is the triple co-axial (triaxial) system, which consists of a small microcatheter, large microcatheter, and 4- or 5-Fr. catheter. This system may be applied to complex interventions. We herein introduce the technique for and advantages of the triaxial system.


Assuntos
Cateterismo/instrumentação , Embolização Terapêutica/instrumentação , Aneurisma/diagnóstico por imagem , Aneurisma/terapia , Aneurisma da Aorta Abdominal/complicações , Aneurisma da Aorta Abdominal/cirurgia , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/terapia , Catéteres , Endoleak/etiologia , Endoleak/terapia , Desenho de Equipamento , Varizes Esofágicas e Gástricas/terapia , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/terapia , Artéria Esplênica/diagnóstico por imagem
10.
Pol J Radiol ; 83: e137-e142, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30038691

RESUMO

PURPOSE: The purpose of this study is to assess the feasibility and usefulness of time-resolved magnetic resonance angiography (TR-MRA) for follow-up of visceral artery aneurysms (VAAs) after embolotherapy. MATERIAL AND METHODS: Twenty-one VAAs (11 splenic, six renal, three internal iliac, and one superior pancreaticoduodenal artery aneurysms) in 18 patients (median age, 64 years; range, 36-88 years) previously treated by embolisation with platinum coils, were evaluated. The mean size of the aneurysm was 10.5 cm3 (range, 0.3-132 cm3). Among them, 19 lesions were treated by aneurysmal packing with or without distal-to-proximal embolisation. For the remaining two lesions, distal-to-proximal embolization alone was performed. The mean observation period after embolotherapy was 35 weeks (range, 4-216). All patients underwent TR-MRA following an intravenous bolus injection of gadolinium chelate. Recanalisation was diagnosed when any portion of the aneurysmal sac was enhanced in the arterial phase. RESULTS: On TR-MRA, two lesions were diagnosed as recanalised. They were confirmed by transcatheter arteriography and re-treated by embolotherapy. For the remaining 19 lesions, there were no findings of recanalisation on TR-MRA. CONCLUSIONS: TR-MRA appears to be a feasible method for follow-up examination of VAAs treated by embolotherapy.

11.
J Vasc Interv Radiol ; 26(6): 856-864.e1, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25851199

RESUMO

PURPOSE: To assess reperfusion rates after coil embolization for pulmonary arteriovenous malformations (PAVMs) using time-resolved magnetic resonance (MR) angiography or pulmonary angiography. MATERIALS AND METHODS: Patients with PAVMs who underwent embolization and met the following inclusion criteria were included: (a) embolization was performed using bare or fibered platinum microcoils or both, (b) the complete cessation of flow was confirmed by digital subtraction angiography, and (c) follow-up examinations were conducted with time-resolved MR angiography or pulmonary angiography. Coil embolization was performed in 16 patients with 24 untreated or reperfused PAVMs. Sac embolization was performed for 12 untreated PAVMs. Feeding artery embolization was performed as primary embolization in each of the 12 reperfused PAVMs. Five PAVMs were treated 2 to 4 times because of reperfusion. The study included 32 coil embolizations. Follow-up images were reviewed, and reperfusion rates were assessed. The relationships between reperfusion and the location of PAVM, size of PAVM (feeding artery and venous sac), coils (number and total length), timing of embolization (primary or repeat embolization), and types of coils used (with or without fibered coils) were examined. RESULTS: Reperfusion rates at 3, 6, 12, and 24 months were 8%, 27%, 36%, and 49%, respectively, for the 12 untreated PAVMs (primary embolization) and 50%, 50%, 92%, and 100%, respectively, for the 12 reperfused PAVMs (repeat embolization) (P = .0062). No significant differences were observed in the other parameters measured. CONCLUSIONS: When evaluated with time-resolved MR angiography or pulmonary angiography, reperfusion rates after coil embolization for PAVM were considerably high, particularly with repeat embolization.


Assuntos
Malformações Arteriovenosas/terapia , Embolização Terapêutica/instrumentação , Angiografia por Ressonância Magnética , Imagem de Perfusão/métodos , Flebografia/métodos , Artéria Pulmonar/anormalidades , Circulação Pulmonar , Veias Pulmonares/anormalidades , Tomografia Computadorizada por Raios X , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Angiografia Digital , Malformações Arteriovenosas/diagnóstico , Malformações Arteriovenosas/fisiopatologia , Feminino , Humanos , Japão , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/fisiopatologia , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/fisiopatologia , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
13.
Acta Radiol ; 56(1): 51-5, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24362647

RESUMO

BACKGROUND: A triple co-axial (triaxial) system, consisting of a 1.9-Fr non-tapered microcatheter with one marker, a 2.7-Fr microcatheter, and a 4-Fr catheter, has been recently developed, and can be used in coil embolizations using 0.010-inch Guglielmi detachable coils (GDCs) with a voltage-dependent coil-detaching technique. PURPOSE: To describe this new technique and evaluate its technical feasibility and clinical efficacy. MATERIAL AND METHODS: Twenty patients underwent this procedure. Diseases were gastrointestinal bleeding in five patients, traumatic bleeding in three patients, and other diseases in 12 patients. The technical success rate, clinical success rate, and complications of this procedure were evaluated. Technical success was defined as the successful delivery and detachment of a GDC, and clinical success was defined as the immediate postembolic complete cessation of blood flow confirmed by digital subtraction angiography. RESULTS: A total of 140 GDCs were used and 20 arteries were embolized. The technical success rate was 94% (131/140) and clinical success rate was 95% (19/20). No major complications were reported. CONCLUSION: The triaxial system in coil embolization using a GDC by monitoring the voltage for coil-detaching appeared to be safe and effective.


Assuntos
Cateterismo Periférico/instrumentação , Remoção de Dispositivo/instrumentação , Embolização Terapêutica/instrumentação , Doença Arterial Periférica/terapia , Dispositivos de Acesso Vascular , Adulto , Idoso , Idoso de 80 Anos ou mais , Remoção de Dispositivo/métodos , Campos Eletromagnéticos , Desenho de Equipamento , Análise de Falha de Equipamento , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Miniaturização , Doença Arterial Periférica/diagnóstico , Doença Arterial Periférica/diagnóstico por imagem , Radiografia , Resultado do Tratamento
14.
Minim Invasive Ther Allied Technol ; 24(2): 119-22, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25140703

RESUMO

OBJECTIVE: Superselective transcatheter arterial embolization (TAE) is important for lower gastrointestinal (GI) bleeding. A new 1.9-Fr. no-taper microcatheter has recently become available and can be inserted into a 2.7-Fr. microcatheter. We assessed the applicability of this new triple co-axial (triaxial) system to TAE for lower GI bleeding. MATERIAL AND METHODS: Five patients with lower GI bleeding underwent TAE with the triaxial system. The approach was via the femoral artery with a 4-Fr. sheath in all cases. The 4-Fr. catheter and triaxial system were inserted into the artery in which extravasation had occurred. Coil embolization was performed with 0.010-inch coils. We evaluated technical success rate, clinical success rate and complications. RESULTS: All five cases of bleeding occurred at the ascending colon, and were caused by diverticulosis in four cases, and an injury to the artery during polypectomy in one case. The 1.9-Fr. no-taper microcatheter could be inserted into the site of extravasation, the vasa recta, in all procedures and TAE was performed successfully. The disappearance of extravasation was confirmed in all cases following TAE. No patients exhibited any signs of recurrent bleeding or complication. CONCLUSION: The triaxial system appears to be effective and useful in superselective TAE for lower GI bleeding.


Assuntos
Cateterismo/instrumentação , Embolização Terapêutica/métodos , Hemorragia Gastrointestinal/terapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Colo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
15.
Pol J Radiol ; 80: 67-71, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25691920

RESUMO

BACKGROUND: Recanalization occurs occasionally, following coil embolization of pulmonary arteriovenous malformations (PAVM), and can lead to ischemic stroke; therefore re-embolization is important. A 1.9-Fr. no-taper microcatheter that can be inserted into a 2.7-Fr. microcatheter (named the triaxial system) has recently become available, and contributes to super-selective catheterization for small or tortuous vessels. The aim of this study was to evaluate the usefulness of re-embolization for recanalization of PAVM using the triaxial system. MATERIAL/METHODS: Recanalization was diagnosed in 8 patients with 13 PAVMs between June 2011 and November 2012, and re-embolization was attempted with a conventional microcatheter at first in all 13 PAVMs. However, in three of them it failed with the conventional microcatheter, and then the system was exchanged to the triaxial system. Thus, re-embolization using the triaxial system was performed in 3 PAVMs of 3 female patients, with a median age of 63 years (range, 46-73 years). We assessed technical success, complications, and outcome. RESULTS: The disappearance of recanalization was confirmed by angiography in all re-embolization procedures (technical success rate was 100%). Re-embolization was then successfully achieved inside the original coils, and no branch artery of normal lung tissue was embolized. There were no complications related with this procedure. The blood flow of recanalization was decreased in all cases in a follow-up of 27-33 months (median, 31). CONCLUSIONS: Triaxial system appears to be useful for recanalization of PAVM, especially in difficult cases with a conventional system.

16.
J Vasc Interv Radiol ; 25(9): 1339-47, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25012936

RESUMO

PURPOSE: To assess the feasibility of time-resolved magnetic resonance (MR) angiography as a follow-up method after embolization for pulmonary arteriovenous malformations (PAVMs). MATERIALS AND METHODS: Evaluation of 28 PAVMs in 10 patients previously treated with embolization with platinum coils was performed. The mean observation period after embolization was 49 months. All patients underwent unenhanced chest computed tomography (CT) and time-resolved MR angiography followed by transcatheter digital subtraction angiography within 5 weeks for a definite diagnosis. Two radiologists reviewed the CT and time-resolved MR angiography findings using a blinded method. On CT, the draining veins of the PAVMs were measured before and after embolization, and shrinkage rates were calculated. On time-resolved MR angiography, recanalization was diagnosed when the draining vein or aneurysmal sac or both were enhanced in the pulmonary arterial phase. Correlations between recanalization, the shrinkage rate of the draining vein, and the diagnostic accuracies of CT and time-resolved MR angiography were assessed and compared with digital subtraction angiography. RESULTS: Five lesions could not be measured on CT because of metallic artifacts. The mean shrinkage rates of the draining vein for recanalized and occluded PAVMs were 23% ± 19 (SD) for recanalized PAVMs and 47% ± 21 for occluded PAVMs (P = .001). The sensitivity and specificity were 93% and 53%, respectively, when the shrinkage rate threshold was set to 50%. On time-resolved MR angiography, the sensitivity and specificity were 93% and 100%, respectively, for Reader 1 and 100% and 93%, respectively, for Reader 2. The κ coefficient was 0.86. CONCLUSIONS: Time-resolved MR angiography appears to be a feasible method for PAVM follow-up examinations and to provide a more accurate diagnosis of recanalization compared with unenhanced CT.


Assuntos
Malformações Arteriovenosas/diagnóstico , Malformações Arteriovenosas/terapia , Embolização Terapêutica/instrumentação , Angiografia por Ressonância Magnética/métodos , Platina , Artéria Pulmonar/anormalidades , Veias Pulmonares/anormalidades , Adulto , Idoso , Angiografia Digital , Artefatos , Embolização Terapêutica/efeitos adversos , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/patologia , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/patologia , Reprodutibilidade dos Testes , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento
18.
Radiol Case Rep ; 19(9): 3618-3621, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38983292

RESUMO

A 75-year-old male, weighing 71 kg, was admitted to our institution with anemia related to a subcapsular hematoma after accidental extraction of a nephrostomy catheter. While the patient exhibited the progression of chronic kidney disease, he was not yet on dialysis. His serum creatinine level increased to 6.8 mg/dL, with an estimated glomerular filtration rate of 7.4 mL/min/1.73 m2. Radiologists planned contrast-enhanced photon-counting detector CT (PCD-CT) with an ultra-low-dose contrast media to mitigate the impact on renal function. The contrast media dosage was set at 7.4 gI, which was 82.6% lower that used in the standard protocol for a male weighing 71 kg. Non-contrast-enhanced PCD-CT identified a low-density nodular area within the renal subcapsular hematoma. Contrast-enhanced PCD-CT revealed contrast enhancement in both the early and late phases corresponding to the nodular area. On virtual monoenergetic images, the renal pseudoaneurysm was most clearly delineated at 40 keV. Following the diagnosis of a pseudoaneurysm, transcatheter arterial coil embolization was performed. No subsequent progression of anemia or the deterioration of renal function was observed, showcasing the potential of ultra-low-dose contrast-enhanced PCD-CT for the detection of small vascular abnormalities while minimizing adverse effects on renal function.

19.
Pol J Radiol ; 78(1): 64-8, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23493525

RESUMO

BACKGROUND: Follow-up imaging after coil embolization of visceral artery aneurysms is important for detecting recanalization. However, CT examination is susceptible to coil artifacts, which sometimes makes it difficult to assess recanalization. We report 2 cases where recanalization was successfully visualized using time-resolved magnetic resonance angiography after coil embolization of visceral artery aneurysms (one case of right internal iliac artery aneurysm and one case of splenic artery aneurysm). Repeat coil embolization was successfully performed. CASE REPORT: Case 1. An 80-year-old male patient with right internal iliac artery (IIA) aneurysm underwent coil embolization. Aneurysm was located at the bifurcation of the right IIA and therefore, after making a femorofemoral bypass, the distal part of the right IIA, aneurysm and the common iliac artery were embolized with a coil. One year later, the size of the aneurysm seemed to have increased on CT. However, the details were not determined because of metal artifacts. Thus, time-resolved MRA was performed and showed minute vascular flow inside the aneurysm. Angiography was subsequently performed and blood flow inside the aneurysm was visualized similar to the findings in time-resolved MRA. Coil embolization was performed once more and vascular flow inside the aneurysm disappeared. Case 2. A 36-year-old male patient with a splenic artery aneurysm underwent coil packing with preservation of splenic artery patency. Four years later, coil compaction was suspected in a CT scan, but CT could not evaluate recanalization because of severe metal artifacts. Angiography was subsequently performed, showing recanalization of the aneurysm as did the time-resolved MRA. Therefore, coil embolization of the aneurysm and splenic artery was performed again. CONCLUSIONS: Follow-up imaging after coil embolization of visceral artery aneurysms is important for detecting recanalization. However, it is sometimes difficult to assess recanalization with CT because of artifacts caused by metal. In our cases, recanalization of aneurysms was clearly shown by time-resolved MRA and re-embolization was successfully performed. In conclusion, time-resolved MRA appears to be useful in assessment of recanalization of visceral artery aneurysms after coil embolization.

20.
Interv Radiol (Higashimatsuyama) ; 8(2): 56-63, 2023 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-37485484

RESUMO

Pulmonary arteriovenous malformations are abnormal connections between a pulmonary artery and a pulmonary vein that can lead to ischemic stroke and brain abscess due to right-to-left shunting of blood. Embolization is currently considered the first treatment option for pulmonary arteriovenous malformations owing to its minimal invasiveness. This review updates the indications and techniques for the embolization of pulmonary arteriovenous malformations and determines the persistence of pulmonary arteriovenous malformations following embolization based on the most recent literature.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA