Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Circulation ; 145(6): 427-436, 2022 02 08.
Artigo em Inglês | MEDLINE | ID: mdl-34882430

RESUMO

BACKGROUND: DANISH (The Danish Study to Assess the Efficacy of Implantable Cardioverter Defibrillators [ICDs] in Patients With Nonischemic Systolic Heart Failure on Mortality) found that primary-prevention ICD implantation was not associated with an overall survival benefit in patients with nonischemic systolic heart failure during a median follow-up of 5.6 years, although there was a beneficial effect on all-cause mortality in patients ≤70 years. This study presents an additional 4 years of follow-up data from DANISH. METHODS: In DANISH, 556 patients with nonischemic systolic heart failure were randomized to receive an ICD and 560 to receive usual clinical care and followed until June 30, 2016. In this long-term follow-up study, patients were followed until May 18, 2020. Analyses were conducted for the overall population and according to age (≤70 and >70 years). RESULTS: During a median follow-up of 9.5 years (25th-75th percentile, 7.9-10.9 years), 208/556 patients (37%) in the ICD group and 226/560 patients (40%) in the control group died. Compared with the control group, the ICD group did not have significantly lower all-cause mortality (hazard ratio [HR] 0.89, [95% CI, 0.74-1.08]; P = 0.24). In patients ≤70 years (n = 829), all-cause mortality was lower in the ICD group than the control group (117/389 [30%] versus 158/440 [36%]; HR, 0.78 [95% CI, 0.61-0.99]; P = 0.04), whereas in patients >70 years (n = 287), all-cause mortality was not significantly different between the ICD and control group (91/167 [54%] versus 68/120 [57%]; HR, 0.92 [95% CI, 0.67-1.28]; P = 0.75). Cardiovascular death showed similar trends (overall, 147/556 [26%] versus 164/560 [29%]; HR, 0.87 [95% CI, 0.70-1.09]; P = 0.20; ≤70 years, 87/389 [22%] versus 122/440 [28%]; HR, 0.75 [95% CI, 0.57-0.98]; P = 0.04; >70 years, 60/167 [36%] versus 42/120 [35%]; HR, 0.97 [95% CI, 0.65-1.45]; P = 0.91). The ICD group had a significantly lower incidence of sudden cardiovascular death in the overall population (35/556 [6%] versus 57/560 [10%]; HR, 0.60 [95% CI, 0.40-0.92]; P = 0.02) and in patients ≤70 years (19/389 [5%] versus 49/440 [11%]; HR, 0.42 [95% CI, 0.24-0.71]; P = 0.0008), but not in patients >70 years (16/167 [10%] versus 8/120 [7%]; HR, 1.34 [95% CI, 0.56-3.19]; P = 0.39). CONCLUSIONS: During a median follow-up of 9.5 years, ICD implantation did not provide an overall survival benefit in patients with nonischemic systolic heart failure. In patients ≤70 years, ICD implantation was associated with a lower incidence of all-cause mortality, cardiovascular death, and sudden cardiovascular death. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT00542945.


Assuntos
Desfibriladores Implantáveis/normas , Insuficiência Cardíaca Sistólica/epidemiologia , Insuficiência Cardíaca Sistólica/mortalidade , Idoso , Dinamarca , Feminino , Seguimentos , Humanos , Incidência , Masculino , Análise de Sobrevida
2.
Qual Life Res ; 28(11): 2901-2908, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31292822

RESUMO

PURPOSE: The "distressed" (Type D) personality trait has been reported to be over-represented in patients with heart failure (HF) compared to the background population and may provide prognostic information for mortality. We examined the association between Type D personality and outcomes in the DANISH trial (The Danish Study to Assess the Efficacy of Implantable Cardioverter Defibrillators in Patients with Non-ischemic Systolic Heart Failure on Mortality). METHODS: The DANISH trial included a total of 1116 patients with non-ischemic HF on guideline-recommended therapy. Type D personality was assessed with the Type D Scale (DS14) at baseline and investigated through follow-up accordingly. Multivariable Cox proportional hazard models were used to compare hazard ratios (HR) of cardiovascular and all-cause mortality. RESULTS: Type D personality assessment was completed by 873 (78%) patients at baseline and Type D personality was found in 120 (14%) patients. The median follow-up was 67 months (interquartile range [IQR] 48-83). Among patients with versus without Type D personality, 22% versus 19% died from all-cause yielding similar incidence rates of 4.62 (95% CI 3.14-6.87) versus 3.95 (95% CI 3.37-4.66) per 100 person-years. The adjusted risk of all-cause mortality was not significantly different in patients with versus without Type D personality with an adjusted HR of 1.31 (95% CI 0.84-2.03, p = 0.23) with similar results for cardiovascular death (HR 1.46 (95% CI 0.88-2.44, p = 0.15). CONCLUSION: Type D personality was not significantly associated with increased risk of all-cause mortality or cardiovascular death in patients with non-ischemic HF.


Assuntos
Desfibriladores Implantáveis/normas , Insuficiência Cardíaca/psicologia , Qualidade de Vida/psicologia , Personalidade Tipo D , Idoso , Feminino , Insuficiência Cardíaca/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Fatores de Risco
3.
Int J Cardiol ; 305: 92-98, 2020 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-32046910

RESUMO

OBJECTIVES: To examine the association between health-related quality of life (HRQoL) and mortality in patients with heart failure (HF). BACKGROUND: The potential association of HRQoL and mortality in patients with HF is unclear. We investigated this association in The Danish Study to Assess the Efficacy of Implantable Cardioverter Defibrillators (ICD) in Patients with Non-ischemic Systolic Heart Failure on Mortality (DANISH). METHODS: In DANISH, a total of 1116 patients with non-ischemic systolic HF on guideline-recommended therapy were randomized to ICD therapy or usual clinical care. HRQoL was assessed at randomization using the disease-specific Minnesota Living with Heart Failure Questionnaire (MLHFQ, 0-105, high score indicating worse HRQoL). Multivariable Cox proportional hazard models were used to compare hazard ratios (HR) for all-cause mortality according to MLHFQ above or below 45, as recommended by a recent meta-analysis, to identify patients with poor HRQoL. RESULTS: HRQoL was completed by 935 (84%) patients at baseline with a median follow-up of 67 months (IQR 47-83). Patients with poor HRQoL (MLHFQ score > 45, median 60 (IQR 53-71),n = 350) had a higher incidence of all-cause mortality than patients with moderate/good HRQoL (MLHFQ ≤45, median 23 (IQR 13-33), n = 585), respectively 26% vs. 18% with an unadjusted HR of 1.57 (95% CI 1.19-2.08, p = .002), and an adjusted HR of 1.39 (95% CI 1.01-1.91, p = .04). CONCLUSION: Poor HRQoL was associated with an increased risk of all-cause mortality after adjustment for traditional risk factors. CLINICAL TRIAL REGISTRATION: https: //clinicaltrials.gov/ct2/show/NCT00542945(DANISH).


Assuntos
Desfibriladores Implantáveis , Insuficiência Cardíaca Sistólica , Insuficiência Cardíaca , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca Sistólica/diagnóstico , Insuficiência Cardíaca Sistólica/terapia , Humanos , Minnesota , Qualidade de Vida , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA