Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Eur J Radiol ; 169: 111191, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37976761

RESUMO

PURPOSE: Diagnostic reference levels (DRL) and achievable doses (AD) are important tools for radiation dose optimization. Therefore, a prospective study was performed which aimed to establish a multi-parametric, clinical indication based - DRL(DRLCI) and clinical indication - AD (ADCI) for adult CT in Brazil. METHODS: The prospective study included 4787 patients (50 ± 18 years old; male:female 2041:2746) at 13 Brazilian sites that have been submitted to head, paranasal sinus, cervical spine, chest, or abdomen-pelvis CT between January and October 2021 for 13 clinical indications. The sites provided the following information: patient age, gender, weight, height, body mass index[BMI], clinical indications, scanner information(vendor, model, detector configuration), scan parameters (number of scan phases, kV, mA, pitch) and dose-related quantities (CT dose index volume- CTDIvol, dose length product- DLP). Median(AD) and 75th(DRL) percentile CTDIvol and DLP values were estimated for each body region and clinical indications. Non-normal data were analyzed with the Kruskal-Wallis test. RESULTS: In majority of Brazilian sites, body region and clinical indications based DRLs were at or lower than the corresponding DRLs in the US and higher than Europe. Although radiation doses varied significantly for patients in different body mass index groups (p < 0.001), within each body region, there were no differences in radiation doses for different clinical indications (p > 0.1). Radiation doses for 7/13 clinical indications were higher using iterative reconstruction technique than for the filtered back projection. CONCLUSIONS: There was substantial variation in Brazil DRLCI across different institutions with higher doses compared to the European standards. There was also a lack of clinical indication-based protocol and dose optimization based on different clinical indications for the same body region.


Assuntos
Níveis de Referência de Diagnóstico , Tomografia Computadorizada por Raios X , Adulto , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Doses de Radiação , Estudos Prospectivos , Brasil/epidemiologia , Valores de Referência , Tomografia Computadorizada por Raios X/métodos
2.
Insights Imaging ; 13(1): 40, 2022 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-35254537

RESUMO

PURPOSE: To evaluate the impact of a paediatric radiological protection campaign, implemented in the emergency units of a healthcare provider network in Brazil. This campaign aimed to promote awareness among emergency department physicians, regarding justification of paediatric X-ray referrals for paranasal sinus, chest and CT exams, as a strategy to reduce exposure to ionising radiation. METHOD: Frequency analysis of common paediatric imaging referrals from 19 emergency departments was performed for a 3-year period (2015-2018) to coincide with before, during and after the implementation of the radiation protection campaign. The campaign was multifaceted and involved dissemination of educational materials and imaging referral guidelines along with quarterly meetings with participating centres' leaderships. Additionally, patient dose cards were distributed to patients/carers. The Chi-Square test was used to examine the association between the type of examination and the patient's age group. Exact-Fisher test was performed to check for an association between participant engagement and the existence of the radiation protection committee. RESULTS: Referrals reduced by 25% following the campaign with no reports of misdiagnosis. Many referrals in the youngest age groups. In 15 units, a radiological protection committee was created to raise awareness and to create a multi professional team to communicate the risks and benefits of radiological procedure in children. CONCLUSION: The campaign resulted in a substantial reduction in radiological referrals while promoting a radiation protection culture. Simple education initiatives can contribute to savings in both finances and radiation doses, particularly important in radiosensitive cohorts.

3.
Phys Med ; 84: 125-131, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33894582

RESUMO

PURPOSE: Optimization of CT scan practices can help achieve and maintain optimal radiation protection. The aim was to assess centering, scan length, and positioning of patients undergoing chest CT for suspected or known COVID-19 pneumonia and to investigate their effect on associated radiation doses. METHODS: With respective approvals from institutional review boards, we compiled CT imaging and radiation dose data from four hospitals belonging to four countries (Brazil, Iran, Italy, and USA) on 400 adult patients who underwent chest CT for suspected or known COVID-19 pneumonia between April 2020 and August 2020. We recorded patient demographics and volume CT dose index (CTDIvol) and dose length product (DLP). From thin-section CT images of each patient, we estimated the scan length and recorded the first and last vertebral bodies at the scan start and end locations. Patient mis-centering and arm position were recorded. Data were analyzed with analysis of variance (ANOVA). RESULTS: The extent and frequency of patient mis-centering did not differ across the four CT facilities (>0.09). The frequency of patients scanned with arms by their side (11-40% relative to those with arms up) had greater mis-centering and higher CTDIvol and DLP at 2/4 facilities (p = 0.027-0.05). Despite lack of variations in effective diameters (p = 0.14), there were significantly variations in scan lengths, CTDIvol and DLP across the four facilities (p < 0.001). CONCLUSIONS: Mis-centering, over-scanning, and arms by the side are frequent issues with use of chest CT in COVID-19 pneumonia and are associated with higher radiation doses.


Assuntos
COVID-19 , Proteção Radiológica , Adulto , Braço , Humanos , Irã (Geográfico) , Itália/epidemiologia , Pandemias , Doses de Radiação , SARS-CoV-2
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA