Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Clin Chem ; 68(1): 218-229, 2021 12 30.
Artigo em Inglês | MEDLINE | ID: mdl-34969114

RESUMO

BACKGROUND: Clinical babesiosis is diagnosed, and parasite burden is determined, by microscopic inspection of a thick or thin Giemsa-stained peripheral blood smear. However, quantitative analysis by manual microscopy is subject to error. As such, methods for the automated measurement of percent parasitemia in digital microscopic images of peripheral blood smears could improve clinical accuracy, relative to the predicate method. METHODS: Individual erythrocyte images were manually labeled as "parasite" or "normal" and were used to train a model for binary image classification. The best model was then used to calculate percent parasitemia from a clinical validation dataset, and values were compared to a clinical reference value. Lastly, model interpretability was examined using an integrated gradient to identify pixels most likely to influence classification decisions. RESULTS: The precision and recall of the model during development testing were 0.92 and 1.00, respectively. In clinical validation, the model returned increasing positive signal with increasing mean reference value. However, there were 2 highly erroneous false positive values returned by the model. Further, the model incorrectly assessed 3 cases well above the clinical threshold of 10%. The integrated gradient suggested potential sources of false positives including rouleaux formations, cell boundaries, and precipitate as deterministic factors in negative erythrocyte images. CONCLUSIONS: While the model demonstrated highly accurate single cell classification and correctly assessed most slides, several false positives were highly incorrect. This project highlights the need for integrated testing of machine learning-based models, even when models in the development phase perform well.


Assuntos
Babesia , Parasitemia , Eritrócitos , Humanos , Microscopia/métodos , Redes Neurais de Computação , Parasitemia/diagnóstico
2.
Clin Chem ; 63(12): 1847-1855, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28877918

RESUMO

BACKGROUND: Morphologic profiling of the erythrocyte population is a widely used and clinically valuable diagnostic modality, but one that relies on a slow manual process associated with significant labor cost and limited reproducibility. Automated profiling of erythrocytes from digital images by capable machine learning approaches would augment the throughput and value of morphologic analysis. To this end, we sought to evaluate the performance of leading implementation strategies for convolutional neural networks (CNNs) when applied to classification of erythrocytes based on morphology. METHODS: Erythrocytes were manually classified into 1 of 10 classes using a custom-developed Web application. Using recent literature to guide architectural considerations for neural network design, we implemented a "very deep" CNN, consisting of >150 layers, with dense shortcut connections. RESULTS: The final database comprised 3737 labeled cells. Ensemble model predictions on unseen data demonstrated a harmonic mean of recall and precision metrics of 92.70% and 89.39%, respectively. Of the 748 cells in the test set, 23 misclassification errors were made, with a correct classification frequency of 90.60%, represented as a harmonic mean across the 10 morphologic classes. CONCLUSIONS: These findings indicate that erythrocyte morphology profiles could be measured with a high degree of accuracy with "very deep" CNNs. Further, these data support future efforts to expand classes and optimize practical performance in a clinical environment as a prelude to full implementation as a clinical tool.


Assuntos
Eritrócitos/citologia , Processamento de Imagem Assistida por Computador/métodos , Redes Neurais de Computação , Bases de Dados Factuais , Eritrócitos/patologia , Humanos
3.
Sci Rep ; 11(1): 5248, 2021 03 04.
Artigo em Inglês | MEDLINE | ID: mdl-33664354

RESUMO

Conventional two-photon microscopes use photomultiplier tubes, which enable high sensitivity but can detect relatively few photons per second, forcing longer pixel integration times and limiting maximum imaging rates. We introduce novel detection electronics using silicon photomultipliers that greatly extend dynamic range, enabling more than an order of magnitude increased photon detection rate as compared to state-of-the-art photomultiplier tubes. We demonstrate that this capability can dramatically improve both imaging rates and signal-to-noise ratio (SNR) in two-photon microscopy using human surgical specimens. Finally, to enable wider use of more advanced detection technology, we have formed the OpenSiPM project, which aims to provide open source detector designs for high-speed two-photon and confocal microscopy.


Assuntos
Eletrônica/métodos , Microscopia Confocal/métodos , Fótons , Cintilografia/métodos , Eletrônica/instrumentação , Humanos , Microscopia Confocal/instrumentação , Cintilografia/instrumentação , Razão Sinal-Ruído , Silício/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA