Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 76
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Comput Assist Tomogr ; 47(5): 698-703, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37707398

RESUMO

OBJECTIVE: To evaluate the image quality and lesion detectability of pancreatic phase thin-slice computed tomography (CT) images reconstructed with a deep learning-based reconstruction (DLR) algorithm compared with filtered-back projection (FBP) and hybrid iterative reconstruction (IR) algorithms. METHODS: Fifty-three patients who underwent dynamic contrast-enhanced CT including pancreatic phase were enrolled in this retrospective study. Pancreatic phase thin-slice (0.625 mm) images were reconstructed with each FBP, hybrid IR, and DLR. Objective image quality and signal-to-noise ratio of the pancreatic parenchyma, and contrast-to-noise ratio of pancreatic lesions were compared between the 3 reconstruction algorithms. Two radiologists independently assessed the image quality of all images. The diagnostic performance for the detection of pancreatic lesions was compared among the reconstruction algorithms using jackknife alternative free-response receiver operating characteristic analysis. RESULTS: Deep learning-based reconstruction resulted in significantly lower image noise and higher signal-to-noise ratio and contrast-to-noise ratio than hybrid IR and FBP ( P < 0.001). Deep learning-based reconstruction also yielded significantly higher visual scores than hybrid IR and FBP ( P < 0.01). The diagnostic performance of DLR for detecting pancreatic lesions was highest for both readers, although a significant difference was found only between DLR and FBP in one reader ( P = 0.02). CONCLUSIONS: Deep learning-based reconstruction showed improved objective and subjective image quality of pancreatic phase thin-slice CT relative to other reconstruction algorithms and has potential for improving lesion detectability.


Assuntos
Aprendizado Profundo , Neoplasias Pancreáticas , Humanos , Estudos Retrospectivos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Neoplasias Pancreáticas/diagnóstico por imagem
2.
Radiol Med ; 128(6): 629-643, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37120661

RESUMO

OBJECTIVES: To compare the image quality of high-resolution diffusion-weighted imaging (DWI) using multiplexed sensitivity encoding (MUSE) versus reduced field-of-view (rFOV) techniques in endometrial cancer (EC) and to compare the diagnostic performance of these techniques with that of dynamic contrast-enhanced (DCE) MRI for assessing myometrial invasion of EC. METHODS: MUSE-DWI and rFOV-DWI were obtained preoperatively in 58 women with EC. Three radiologists assessed the image quality of MUSE-DWI and rFOV-DWI. For 55 women who underwent DCE-MRI, the same radiologists assessed the superficial and deep myometrial invasion using MUSE-DWI, rFOV-DWI, and DCE-MRI. Qualitative scores were compared using the Wilcoxon signed-rank test. Receiver operating characteristic analysis was performed to compare the diagnostic performance. RESULTS: Artifacts, sharpness, lesion conspicuity, and overall quality were significantly better with MUSE-DWI than with rFOV-DWI (p < 0.05). The area under the curve (AUC) of MUSE-DWI, rFOV-DWI, and DCE-MRI for the assessment of myometrial invasion were not significantly different except for significantly higher AUC of MUSE-DWI than that of DCE-MRI for superficial myometrial invasion (0.76 for MUSE-DWI and 0.64 for DCE-MRI, p = 0.049) and for deep myometrial invasion (0.92 for MUSE-DWI and 0.80 for DCE-MRI, p = 0.022) in one observer, and that of rFOV-DWI for deep myometrial invasion in another observer (0.96 for MUSE-DWI and 0.89 for rFOV-MRI, p = 0.048). CONCLUSION: MUSE-DWI exhibits better image quality than rFOV-DWI. MUSE-DWI and rFOV-DWI shows almost equivalent diagnostic performance compared to DCE-MRI for assessing superficial and deep myometrial invasion in EC although MUSE-DWI may be helpful for some radiologists.


Assuntos
Alprostadil , Neoplasias do Endométrio , Feminino , Humanos , Sensibilidade e Especificidade , Imageamento por Ressonância Magnética/métodos , Imagem de Difusão por Ressonância Magnética/métodos , Neoplasias do Endométrio/diagnóstico por imagem , Neoplasias do Endométrio/patologia
3.
Radiographics ; 42(7): 2095-2111, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36083804

RESUMO

Borderline epithelial ovarian tumors are a distinct pathologic entity characterized by increased epithelial proliferation and nuclear atypia, but without frank stromal invasion. Borderline tumor (BT) is now considered to represent an intermediate phase in the stepwise progression from benign to malignant ovarian epithelial tumor. Since BTs commonly manifest at early stages in women of reproductive age and are associated with a good prognosis, making the correct diagnosis is important in determining whether a patient is a candidate for fertility-sparing surgery. There are six histologic BT subtypes (serous, mucinous, seromucinous, endometrioid, clear cell, and Brenner), and each has different MRI features, reflecting their unique histologic architectures. Radiologists should be aware of the MRI features that can suggest BTs. These features include a hyperintense papillary architecture with hypointense internal branching, which can be observed with serous and seromucinous BTs on T2-weighted images; aggregates of microcysts that have hypointensity on T2-weighted images and reticular enhancement on contrast-enhanced T2-weighted images, which can be seen with mucinous BTs; and moderately high signal intensity on diffusion-weighted images along with relatively high apparent diffusion coefficient values, which can be observed regardless of the histologic subtype. Nevertheless, because the imaging features of BTs overlap with those of many benign lesions (eg, cystadenoma and cystadenofibroma, decidualized endometriosis, and polypoid endometriosis) and malignant tumors (ovarian cancers and metastases), histologic confirmation is required for the final diagnosis. Special emphasis is placed on the MRI features of BTs, pathologic correlation, and the challenges related to diagnosis. ©RSNA, 2022.


Assuntos
Carcinoma , Endometriose , Neoplasias Ovarianas , Feminino , Humanos , Neoplasias Ovarianas/patologia , Imageamento por Ressonância Magnética , Imagem de Difusão por Ressonância Magnética/métodos
4.
Radiology ; 289(1): 255-260, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-29944085

RESUMO

Purpose To examine the diagnostic performance of high-spatial-resolution (HSR) CT with 0.25-mm section thickness for evaluating renal artery in-stent restenosis. Materials and Methods A 0.05-mm wire phantom and vessel phantoms with renal stents with in-stent stenotic sections of varying diameters were scanned with both an HSR CT scanner equipped with 160-section multi-detector rows (0.25-mm section thickness) and a conventional CT scanner. The wire phantom was used to analyze modulation transfer function (MTF). With the vessel phantoms, the error rates were calculated as the absolute difference between the measured diameters and true diameters divided by the true diameters at the narrowing sections. For qualitative evaluation, overall image quality and diagnostic accuracy for evaluating stenosis in three stages were assessed by two radiologists. Statistical analyses included the paired t test, Wilcoxon signed-rank test, and McNemar test. Results HSR CT achieved 24.3 line pairs per centimeter ± 0.5 (standard deviation) and 29.1 line pairs per centimeter ± 0.4 at 10% and 2% MTF, respectively; and conventional CT was 12.5 line pairs per centimeter ± 0.1 and 14.3 line pairs per centimeter ± 0.1 at 10% and 2% MTF, respectively. The mean error rate of the measured diameter at HSR CT (8.0% ± 5.8) was significantly lower than that at at conventional CT (16.9% ± 9.3; P < .001). Image quality at HSR CT was significantly better than that at conventional CT (P < .001), but HSR CT was not significantly superior to conventional CT in terms of diagnostic accuracy. Conclusion Compared with conventional CT, high-spatial-resolution CT achieved spatial resolutions of up to 29 line pairs per centimeter at 2% modulation transfer function and yielded improved measurement accuracy for the evaluation of in-stent restenosis in a phantom study of renal artery stents. Published under a CC BY 4.0 license.


Assuntos
Oclusão de Enxerto Vascular/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Imagens de Fantasmas , Stents , Tomografia Computadorizada por Raios X/métodos , Desenho de Equipamento , Humanos , Modelos Biológicos , Artéria Renal/diagnóstico por imagem , Obstrução da Artéria Renal/diagnóstico por imagem , Tomografia Computadorizada por Raios X/instrumentação
5.
J Comput Assist Tomogr ; 42(3): 412-417, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29189400

RESUMO

OBJECTIVES: The aim of this study was to evaluate the diagnostic ability of magnetic resonance imaging (MRI) in premenopausal women with G1 endometrial carcinoma. METHODS: Twenty-six patients underwent T2W, diffusion weighted, and dynamic contrast-enhanced 3-T MRI. The degree of myometrial invasion was pathologically classified into no invasion, shallow (3 mm or less), and more. Two radiologists assessed myometrial invasion on MRI. Diagnostic accuracy, sensitivity, specificity, positive and negative predictive values, AUC, and interobserver agreement were analyzed. RESULTS: For assessing myometrial invasion, mean accuracy, sensitivity, specificity, positive predictive values, negative predictive values, and AUC, respectively, were as follows: 63%, 42%, 85%, 79%, 47%, and 0.75. Mean interobserver agreement was fair (k = 0.36). Shallow invasions were underestimated as no invasion on MRI in all 6 cases. CONCLUSIONS: Magnetic resonance imaging produced false-negative result on half of patients. The misjudgments tended to happen in patients with shallow invasion.


Assuntos
Neoplasias do Endométrio/diagnóstico por imagem , Preservação da Fertilidade , Imageamento por Ressonância Magnética/métodos , Miométrio/diagnóstico por imagem , Seleção de Pacientes , Pré-Menopausa , Adulto , Neoplasias do Endométrio/patologia , Feminino , Humanos , Pessoa de Meia-Idade , Miométrio/patologia , Invasividade Neoplásica , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
6.
Acta Radiol ; 59(9): 1029-1037, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29235879

RESUMO

Background Rapid injection of gadoxetic acid is reported to produce more frequent artifacts and lower vascular enhancement on arterial phase liver magnetic resonance imaging (MRI). However, its effect on tumor enhancement and the mechanism of the artifacts remain unclear. Purpose To evaluate the effect of rapid injection of gadoxetic acid on artifacts and tumor enhancement during arterial phase liver MRI, and on arterial blood gases (ABGs) which may explain the cause of the artifacts. Material and Methods ABG analysis was performed in 13 free-breathing rabbits after rapid injection (1 mL/s; injection time = 0.6-0.8 s) of gadoxetic acid (0.025 mmol/kg). Dynamic liver MRI was performed in six anesthetized rabbits with VX2 tumors under a ventilation stoppage after rapid and slow injection (0.25 mL/s; injection time = 2.4-3.2 s) of gadoxetic acid. Artifacts and signal enhancement on arterial phase imaging were compared with those obtained after rapid injection of gadopentetic acid (Gd-DTPA, 0.1 mmol/kg) using a Friedman test or Kruskal-Wallis test. Results ABG analysis did not find any significant changes. Artifacts were not related to injection protocols ( P = 0.95). Aortic enhancement with slow injection of gadoxetic acid was significantly higher than that with rapid injection ( P < 0.05), and was comparable to that with Gd-DTPA injection. Tumor enhancement obtained with gadoxetic acid was not significantly different between rapid and slow injection, and was significantly lower than that with Gd-DTPA injection ( P < 0.05). Conclusion Rapid injection of gadoxetic acid did not affect ABGs and may not be the cause of the artifacts. It lowered vascular enhancement but not arterial tumor enhancement.


Assuntos
Artefatos , Meios de Contraste/farmacologia , Gadolínio DTPA/farmacologia , Neoplasias Hepáticas Experimentais/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Animais , Gasometria , Meios de Contraste/administração & dosagem , Gadolínio DTPA/administração & dosagem , Coelhos
7.
Eur Radiol ; 27(12): 5225-5235, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28674966

RESUMO

OBJECTIVES: To compare the image quality and diagnostic performance of reduced field-of-view (rFOV) versus conventional full field-of-view (fFOV) diffusion-weighted (DW) imaging of endometrial cancer. METHODS: Fifty women with endometrial cancer underwent preoperative rFOV and fFOV DW imaging. Two radiologists compared the image qualities of both techniques, and five radiologists assessed superficial and deep myometrial invasion using both techniques. The statistical analysis included the Wilcoxon signed-rank test and paired t-test for comparisons of image quality and mean diagnostic values. RESULTS: Distortion, tumour delineation, and overall image quality were significantly better with rFOV DW imaging, compared to fFOV DW imaging (P < 0.05); however, the former was inferior in noise (P < 0.05). Regarding superficial invasion, the mean accuracies of the techniques did not differ statistically (rFOV, 58.0% versus fFOV, 56.0%; P = 0.30). Regarding deep myometrial invasion, rFOV DW imaging yielded significantly better mean accuracy, specificity, and positive predictive values (88.4%, 97.8%, and 91.7%, respectively), compared with fFOV DW imaging (84.8%, 94.1%, and 77.4%, respectively; P = 0.009, 0.005, and 0.011, respectively). CONCLUSIONS: Compared with fFOV DW imaging, rFOV DW imaging yielded less distortion, improved image quality and, consequently, better diagnostic performance for deep myometrial invasion of endometrial cancer. KEY POINTS: • rFOV DWI yields better assessment of deep myometrial invasion in endometrial cancer. • rFOV DWI could not sufficiently evaluate superficial invasion in endometrial cancer. • Distortion, tumour delineation, and overall image quality were improved with rFOV DWI.


Assuntos
Adenocarcinoma/patologia , Carcinossarcoma/patologia , Imagem de Difusão por Ressonância Magnética/métodos , Neoplasias do Endométrio/patologia , Endométrio/patologia , Procedimentos Cirúrgicos em Ginecologia , Estadiamento de Neoplasias/métodos , Adenocarcinoma/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinossarcoma/cirurgia , Neoplasias do Endométrio/cirurgia , Estudos de Viabilidade , Feminino , Humanos , Pessoa de Meia-Idade , Miométrio/patologia , Invasividade Neoplásica/patologia , Período Pré-Operatório , Curva ROC
8.
J Comput Assist Tomogr ; 39(4): 629-34, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26125298

RESUMO

OBJECTIVE: To evaluate the image quality and radiation dose reduction in pelvic computed tomography (CT) achieved with an adaptive iterative dose reduction 3-dimensional (AIDR 3D) algorithm using a phantom model. METHODS: Two phantoms were scanned using a 320-detector row CT scanner with 8 tube current levels, and the images were reconstructed with a standard filtered back projection (FBP) algorithm and with an AIDR 3D algorithm. RESULTS: Compared with FBP, AIDR 3D reduced image noise and improved contrast-to-noise ratios. The diagnostic performance for detection of low-contrast targets of AIDR 3D images obtained with 100 mA at 120 kVp was almost as good as that of the FBP images obtained with 200 mA. CONCLUSIONS: The AIDR 3D algorithm substantially reduced image noise and improved the image quality of pelvic CT images compared with those obtained with the FBP algorithm and can thus be considered a promising technique for low-dose pelvic CT examinations.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Pelve/diagnóstico por imagem , Imagens de Fantasmas , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Humanos , Doses de Radiação , Razão Sinal-Ruído
9.
Acta Radiol ; 56(9): 1034-41, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25267921

RESUMO

BACKGROUND: Diffusion-weighted magnetic resonance imaging (DW-MRI) and 2-deoxy-2-[18F]fluoro-D-glucose-positron emission tomography/computed tomography (PET/CT) is increasingly recognized as important for assessing tumor malignancy in oncology. Apparent diffusion coefficient (ADC) and standardized uptake value (SUV) are negatively correlated in some types of cancer based on tumor aggressiveness. PURPOSE: To evaluate relationships between ADC of magnetic resonance imaging and SUV of PET/CT in pancreatic adenocarcinomas. MATERIAL AND METHODS: Twenty-nine patients histopathologically diagnosed with pancreatic adenocarcinomas were evaluated. ADC maps were generated from 3 T-MRI using b values (b = 0, 800 s/mm(2)). PET/CT was performed 60 min after intravenous injection of FDG (3.7 MBq/kg). The margins of tumors on DW-MRI and PET/CT were assessed to measure ADC and SUV of tumor appropriately. For tumors considered well-marginated, minimal and mean ADC as well as maximal and mean SUV were measured. The correlation of ADC and SUV were statistically evaluated and survival period stratified on ADC and SUV also evaluated. RESULTS: Twenty-two tumors on DW-MRI and 25 on PET/CT were deemed well-marginated. Minimal ADC was significantly and negatively correlated with maximal and mean SUV (r = -0.61, P = 0.0040; r = -0.66, P = 0.0015), and mean ADC also showed significantly and negatively correlation with maximal and mean SUV (r = -0.50, P = 0.024; r = -0.54, P = 0.012). There was no significant difference on overall survival stratified on ADC and SUV. CONCLUSION: ADC and SUV were significantly correlated in pancreatic adenocarcinomas, although no significant findings were observed in overall survival.


Assuntos
Adenocarcinoma/diagnóstico , Imagem Multimodal , Neoplasias Pancreáticas/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Imagem de Difusão por Ressonância Magnética , Feminino , Fluordesoxiglucose F18 , Humanos , Masculino , Pessoa de Meia-Idade , Invasividade Neoplásica , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos , Técnicas de Imagem de Sincronização Respiratória , Estudos Retrospectivos , Taxa de Sobrevida , Tomografia Computadorizada por Raios X , Neoplasias Pancreáticas
10.
J Magn Reson Imaging ; 39(1): 42-50, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24339365

RESUMO

PURPOSE: To investigate the effect of hepatic steatosis on enhancement of liver parenchyma with gadoxetate disodium-enhanced MR imaging. MATERIALS AND METHODS: Gadoxetate disodium-enhanced MR images of 166 patients were analyzed. Liver-spleen contrast and liver-spleen relative enhancement ratio on three-dimensional gradient echo T1-weighted images with fat suppression 20 minutes after injection of gadoxetate disodium were evaluated in correlation with fat signal fraction using the Pearson correlation coefficient and also compared between patients with normal liver parenchyma (n = 115) and with liver steatosis (n = 51) using the Student t-test. RESULTS: The liver-spleen contrast at hepatobiliary phase showed inverse correlations with the fat signal fraction (r = -0.36; P < 0.01), while the liver-spleen relative enhancement ratio showed no statistical correlation with the fat signal fraction (P = 0.80). The liver-spleen contrast in the group with steatotic liver was significantly lower than that in the group with normal livers (P < 0.001). There was no significant difference in the relative enhancement ratio between the two groups (P = 0.85). CONCLUSION: Our results may suggest that hepatic steatosis does not affect the uptake of gadoxetate disodium into hepatocytes and are considered crucial as background knowledge in extending the use of gadoxetate disodium-enhanced MR imaging to quantitate liver function.


Assuntos
Fígado Gorduroso/diagnóstico , Gadolínio DTPA/química , Hepatócitos/metabolismo , Imageamento por Ressonância Magnética , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste/química , Fígado Gorduroso/patologia , Feminino , Hepatócitos/efeitos dos fármacos , Humanos , Aumento da Imagem , Fígado/patologia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Baço/patologia , Adulto Jovem
11.
Jpn J Radiol ; 42(6): 599-611, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38351253

RESUMO

PURPOSE: Liver and pancreatic fibrosis is associated with diabetes mellitus (DM), and liver fibrosis is associated with pancreatic fibrosis. This study aimed to investigate the relationship between the hepatic and pancreatic extracellular volume fractions (fECVs), which correlate with tissue fibrosis, and their relationships with DM and pre-DM (pDM). MATERIAL AND METHODS: We included 100 consecutive patients with known or suspected liver and/or pancreatic diseases who underwent contrast-enhanced CT. Patients were classified as nondiabetes, pDM, and DM with hemoglobin A1c (HbA1c) levels of < 5.7%, 5.7%-6.5%, and ≥ 6.5% or fasting plasma glucose (FPG) levels of < 100, 100-125 mg/dL, and ≥ 126 mg/dL, respectively. Subtraction images between unenhanced and equilibrium-phase images were prepared. The liver and the pancreas were automatically extracted using a high-speed, three-dimensional image analysis system, and their respective mean CT values were calculated. The enhancement degree of the aorta (Δaorta) was measured. fECV was calculated using the following equation: fECV = (100 - hematocrit) * Δliver or pancreas/Δaorta. Differences were investigated in hepatic and pancreatic fECVs among the three groups, and the correlation between each two in hepatic fECV, pancreatic fECV, and HbA1c was determined. RESULTS: The pancreatic fECV, which was positively correlated with the hepatic fECV and HbA1c (r = 0.51, P < 0.001, and r = 0.51, P < 0.001, respectively), significantly differed among the three groups (P < 0.001) and was significantly greater in DM than in pDM or nondiabetes and in pDM with nondiabetes (P < 0.001). Hepatic fECV was significantly greater in DM than in nondiabetes (P < 0.05). CONCLUSION: The pancreatic fECV and pDM/DM are closely related.


Assuntos
Meios de Contraste , Fígado , Estado Pré-Diabético , Tomografia Computadorizada por Raios X , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X/métodos , Idoso , Fígado/diagnóstico por imagem , Estado Pré-Diabético/diagnóstico por imagem , Pâncreas/diagnóstico por imagem , Pâncreas/patologia , Adulto , Diabetes Mellitus/diagnóstico por imagem , Idoso de 80 Anos ou mais , Imageamento Tridimensional/métodos , Cirrose Hepática/diagnóstico por imagem , Estudos Retrospectivos
12.
Magn Reson Med Sci ; 23(2): 214-224, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-36990740

RESUMO

PURPOSE: To compare the effects of deep learning reconstruction (DLR) on respiratory-triggered T2-weighted MRI of the liver between single-shot fast spin-echo (SSFSE) and fast spin-echo (FSE) sequences. METHODS: Respiratory-triggered fat-suppressed liver T2-weighted MRI was obtained with the FSE and SSFSE sequences at the same spatial resolution in 55 patients. Conventional reconstruction (CR) and DLR were applied to each sequence, and the SNR and liver-to-lesion contrast were measured on FSE-CR, FSE-DLR, SSFSE-CR, and SSFSE-DLR images. Image quality was independently assessed by three radiologists. The results of the qualitative and quantitative analyses were compared among the four types of images using repeated-measures analysis of variance or Friedman's test for normally and non-normally distributed data, respectively, and a visual grading characteristics (VGC) analysis was performed to evaluate the image quality improvement by DLR on the FSE and SSFSE sequences. RESULTS: The liver SNR was lowest on SSFSE-CR and highest on FSE-DLR and SSFSE-DLR (P < 0.01). The liver-to-lesion contrast did not differ significantly among the four types of images. Qualitatively, noise scores were worst on SSFSE-CR but best on SSFSE-DLR because DLR significantly reduced noise (P < 0.01). In contrast, artifact scores were worst both on FSE-CR and FSE-DLR (P < 0.01) because DLR did not reduce the artifacts. Lesion conspicuity was significantly improved by DLR compared with CR in the SSFSE (P < 0.01) but not in FSE sequences for all readers. Overall image quality was significantly improved by DLR compared with CR for all readers in the SSFSE (P < 0.01) but only one reader in the FSE (P < 0.01). The mean area under the VGC curve values for the FSE-DLR and SSFSE-DLR sequences were 0.65 and 0.94, respectively. CONCLUSION: In liver T2-weighted MRI, DLR produced more marked improvements in image quality in SSFSE than in FSE.


Assuntos
Aprendizado Profundo , Neoplasias Hepáticas , Humanos , Imageamento por Ressonância Magnética/métodos , Neoplasias Hepáticas/patologia , Artefatos
13.
Abdom Radiol (NY) ; 2024 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-38888738

RESUMO

Photon-counting CT has a completely different detector mechanism than conventional energy-integrating CT. In the photon-counting detector, X-rays are directly converted into electrons and received as electrical signals. Photon-counting CT provides virtual monochromatic images with a high contrast-to-noise ratio for abdominal CT imaging and may improve the ability to visualize small or low-contrast lesions. In addition, photon-counting CT may offer the possibility of reducing radiation dose. This review provides an overview of the actual clinical operation of photon-counting CT and its diagnostic utility in abdominal imaging. We also describe the clinical implications of photon-counting CT including imaging of hepatocellular carcinoma, liver metastases, hepatic steatosis, pancreatic cancer, intraductal mucinous neoplasm of the pancreas, and thrombus.

14.
Eur Radiol ; 23(8): 2296-305, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23508278

RESUMO

OBJECTIVES: To prospectively assess the efficacy of 3-T magnetic resonance (MR) imaging using the three-dimensional turbo spin-echo T2-weighted and diffusion-weighted technique (3D-TSE/DW) compared with that of conventional imaging using the two-dimensional turbo spin-echo T2-weighted and dynamic contrast-enhanced technique (2D-TSE/DCE) for the preoperative staging of endometrial cancer, with pathological analysis as the reference standard. METHODS: Seventy-one women with endometrial cancer underwent MR imaging using 3D-TSE/DW (b = 1,000 s/mm(2)) and 2D-TSE/DCE. Two radiologists independently assessed the two imaging sets. Accuracy, sensitivity, and specificity for staging were analysed with the McNemar test; the areas under the receiver operating characteristic curve (Az) were compared with a univariate z-score test. RESULTS: The results for assessing deep myometrial invasion, accuracy, sensitivity, specificity and Az, respectively, were as follows: 3D-TSE/DW-observer 1, 87 %, 95 %, 85 % and 0.96; observer 2, 92 %, 84 %, 94 % and 0.95; 2D-TSE/DCE-observer 1, 80 %, 79 %, 81 % and 0.89; observer 2, 86 %, 84 %, 87 % and 0.86. Most of the values were higher with 3D-TSE/DW without significant differences (P > 0.12). For assessing cervical stromal invasion, there were no significant differences in those values for both observers (P > 0.6). CONCLUSIONS: Accuracy of 3D-TSE/DW was at least equivalent to that of the conventional technique for the preoperative assessment of endometrial cancer. KEY POINTS: • New techniques in MR imaging help assess patients with endometrial cancer. • A 3D T2-weighted TSE sequence seems equally as accurate as conventional techniques. • Three-dimensional TSE/DW imaging does not require intravenous contrast material and is relatively quick. • Tumour extent of endometrial cancer can be clearly shown on diffusion-weighted images. • Junctional zone can be visualised well on 3D-TSE T2-weighted images.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Neoplasias do Endométrio/diagnóstico , Neoplasias do Endométrio/cirurgia , Imageamento Tridimensional/métodos , Estadiamento de Neoplasias/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste/química , Neoplasias do Endométrio/patologia , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Pessoa de Meia-Idade , Miométrio/patologia , Variações Dependentes do Observador , Estudos Prospectivos , Curva ROC , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
15.
Magn Reson Med Sci ; 2023 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-37899224

RESUMO

PURPOSE: To compare objective and subjective image quality, lesion conspicuity, and apparent diffusion coefficient (ADC) of high-resolution multiplexed sensitivity-encoding diffusion-weighted imaging (MUSE-DWI) with conventional DWI (c-DWI) and reduced FOV DWI (rFOV-DWI) in prostate MRI. METHODS: Forty-seven patients who underwent prostate MRI, including c-DWI, rFOV-DWI, and MUSE-DWI, were retrospectively evaluated. SNR and ADC of normal prostate tissue and contrast-to-noise ratio (CNR) and ADC of prostate cancer (PCa) were measured and compared between the three sequences. Image quality and lesion conspicuity were independently graded by two radiologists using a 5-point scale and compared between the three sequences. RESULTS: The SNR of normal prostate tissue was significantly higher with rFOV-DWI than with the other two DWI techniques (P ≤ 0.01). The CNR of the PCa was significantly higher with rFOV-DWI than with MUSE-DWI (P < 0.05). The ADC of normal prostate tissue measured by rFOV-DWI was lower than that measured by MUSE-DWI and c-DWI (P < 0.01), while there was no difference in the ADC of cancers. In the qualitative analysis, MUSE-DWI showed significantly higher scores than rFOV-DWI and c-DWI for visibility of anatomy and overall image quality in both readers, and significantly higher scores for distortion in one of the two readers (P < 0.001). There was no difference in lesion conspicuity between the three sequences. CONCLUSION: High-resolution MUSE-DWI showed higher image quality and reduced distortion compared to c-DWI, while maintaining a wide FOV and similar ADC quantification, although no difference in lesion conspicuity was observed.

16.
Invest Radiol ; 2023 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-37975732

RESUMO

OBJECTIVE: The aim of this study was to evaluate the impact of ultra-high-resolution acquisition and deep learning reconstruction (DLR) on the image quality and diagnostic performance of T2-weighted periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) imaging of the rectum. MATERIALS AND METHODS: This prospective study included 34 patients who underwent magnetic resonance imaging (MRI) for initial staging or restaging of rectal tumors. The following 4 types of oblique axial PROPELLER images perpendicular to the tumor were obtained: a standard 3-mm slice thickness with conventional reconstruction (3-CR) and DLR (3-DLR), and 1.2-mm slice thickness with CR (1.2-CR) and DLR (1.2-DLR). Three radiologists independently evaluated the image quality and tumor extent by using a 5-point scoring system. Diagnostic accuracy was evaluated in 22 patients with rectal cancer who underwent surgery after MRI without additional neoadjuvant therapy (median interval between MRI and surgery, 22 days). The signal-to-noise ratio and tissue contrast were measured on the 4 types of PROPELLER imaging. RESULTS: 1.2-DLR imaging showed the best sharpness, overall image quality, and rectal and lesion conspicuity for all readers (P < 0.01). Of the assigned scores for tumor extent, extramural venous invasion (EMVI) scores showed moderate agreement across the 4 types of PROPELLER sequences in all readers (intraclass correlation coefficient, 0.60-0.71). Compared with 3-CR imaging, the number of cases with MRI-detected extramural tumor spread was significantly higher with 1.2-DLR imaging (19.0 ± 2.9 vs 23.3 ± 0.9, P = 0.03), and the number of cases with MRI-detected EMVI was significantly increased with 1.2-CR, 3-DLR, and 1.2-DLR imaging (8.0 ± 0.0 vs 9.7 ± 0.5, 11.0 ± 2.2, and 12.3 ± 1.7, respectively; P = 0.02). For the diagnosis of histopathologic extramural tumor spread, 3-CR and 1.2-CR had significantly higher specificity than 3-DLR and 1.2-DLR imaging (0.75 and 0.78 vs 0.64 and 0.58, respectively; P = 0.02), and only 1.2-CR had significantly higher accuracy than 3-CR imaging (0.83 vs 0.79, P = 0.01). The accuracy of MRI-detected EMVI with reference to pathological EMVI was significantly lower for 3-CR and 3-DLR compared with 1.2-CR (0.77 and 0.74 vs 0.85, respectively; P < 0.01), and was not significantly different between 1.2-CR and 1.2-DLR (0.85 vs 0.80). Using any pathological venous invasion as the reference standard, the accuracy of MRI-detected EMVI was significantly the highest with 1.2-DLR, followed by 1.2-CR, 3-CR, and 3-DLR (0.71 vs 0.67 vs 0.59 vs 0.56, respectively; P < 0.01). The signal-to-noise ratio was significantly highest with 3-DLR imaging (P < 0.05). There were no significant differences in tumor-to-muscle contrast between the 4 types of PROPELLER imaging. CONCLUSIONS: Ultra-high-resolution PROPELLER T2-weighted imaging of the rectum combined with DLR improved image quality, increased the number of cases with MRI-detected extramural tumor spread and EMVI, but did not improve diagnostic accuracy with respect to pathology in rectal cancer, possibly because of false-positive MRI findings or false-negative pathologic findings.

17.
Eur Radiol ; 22(4): 872-9, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22120061

RESUMO

PURPOSE: This study was aimed to compare the accuracy, sensitivity, and positive predictive value of C-arm CT (CACT) during selective transcatheter angiography with those of multidetector CT (MDCT) in the detection of hepatocellular carcinoma (HCC). MATERIAL AND METHODS: In this prospective study, 30 patients (mean age, 73 years) with unresectable HCC were examined with CACT before chemoembolisation. Images of a combination of CACT during arterial portography (CACTAP) and dual-phase CACT during hepatic arteriography (CACTHA) was obtained and images of intravenous contrast-enhanced, biphasic, dynamic, MDCT was also obtained beforehand. Three blinded observers independently reviewed CACT and MDCT. Diagnostic accuracy was evaluated by the alternative free-response receiver operating characteristic (AFROC) method. Sensitivities and positive predictive values (PPV) were analyzed with the paired t-test. RESULTS: In the mean area under the AFROC curve (Az), there was no significant difference between MDCT and CACT (MDCT, mean Az value, 0.83; CACT, 0.85, respectively) (P = 0.32). There was also no significant difference between the two techniques in sensitivity (MDCT, mean 0.65; CACT, 0.60) and PPV (MDCT, mean 0.98; CACT, 0.97) (P = 0.40, P = 0.68, respectively). CONCLUSION: The diagnostic accuracy of CACT was equivalent to that of biphasic CT in the diagnosis of HCC. KEY POINTS: C-arm CT helps detection of hepatocellular carcinoma (HCC) during interventional (TACE) treatment. C-arm CT for HCC seemed just as accurate as biphasic CT. TACE can be performed with greater confidence using C-arm CT.


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Iopamidol/análogos & derivados , Neoplasias Hepáticas/diagnóstico por imagem , Portografia/instrumentação , Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Angiografia/métodos , Cateterismo , Meios de Contraste/administração & dosagem , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Injeções Intra-Arteriais , Injeções Intravenosas , Iopamidol/administração & dosagem , Masculino , Pessoa de Meia-Idade , Portografia/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
18.
Eur Radiol ; 22(4): 845-54, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22057248

RESUMO

OBJECTIVES: To retrospectively compare the accuracy of detection of hypervascular hepatocellular carcinoma (HCC) by multiphasic multidetector CT and by gadoxetate disodium-enhanced MR imaging. METHODS: After ethical approval, we analysed a total of 73 hypervascular HCC lesions from 31 patients suspected of having HCC, who underwent both gadoxetate disodium-enhanced MR imaging and multiphasic multidetector CT. Five blinded observers independently reviewed CT images, as well as dynamic MR images alone and combined with hepatobiliary phase MR images. Diagnostic accuracy (Az values), sensitivities and positive predictive values were compared by using the Scheffe post hoc test. RESULTS: The mean Az value for dynamic and hepatobiliary phase MR combined (0.81) or dynamic MR images alone (0.78) was significantly higher than that for CT images (0.67, P < 0.001, 0.005, respectively). The mean sensitivity of the combined MR images (0.67) was significantly higher than that of dynamic MR alone (0.52, P < 0.05) or CT images (0.44, P < 0.05). The mean positive predictive values were 0.96, 0.95 and 0.94, for CT, dynamic MR alone and combined MR images, respectively. CONCLUSIONS: Compared with multiphasic multidetector CT, gadoxetate disodium-enhanced MR imaging combining dynamic and hepatobiliary phase images results in significantly improved sensitivity and diagnostic accuracy for detection of hypervascular HCC. KEY POINTS: Gadoxetate disodium is a new liver-specific MR imaging contrast agent. Gadoxetate disodium-enhanced MRI helps the assessment of patients with liver disease. It showed high diagnostic accuracy for the detection of hepatocellular carcinoma.


Assuntos
Carcinoma Hepatocelular/diagnóstico , Gadolínio DTPA , Neoplasias Hepáticas/diagnóstico , Imageamento por Ressonância Magnética/métodos , Neovascularização Patológica/diagnóstico , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Humanos , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
19.
Invest Radiol ; 57(6): 379-386, 2022 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-34999668

RESUMO

OBJECTIVE: This study aimed to evaluate the effects of deep learning (DL) reconstruction and a postprocessing sharpening filter on the image quality of single-shot fast spin-echo (SSFSE) T2-weighted imaging (T2WI) of the uterus. MATERIALS AND METHODS: Fifty consecutive patients who underwent pelvic magnetic resonance imaging were included. Parasagittal T2WI with a slice thickness of 4 mm was obtained with the periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) and SSFSE sequences (mean scan time, 204 and 22 seconds, respectively). The following 3 types of SSFSE images were reconstructed, and the signal-to-noise ratio (SNR) and tissue contrast were assessed: conventional reconstruction (SSFSE-C), DL reconstruction (SSFSE-DL), and DL with a sharpening filter (SSFSE-DLF). Three radiologists independently assessed image quality, and area under the visual grading characteristics curve (AUCVGC) analysis was performed to compare the SSFSE and PROPELLER images. RESULTS: Compared with that of the PROPELLER images, the SNR of the SSFSE-C, SSFSE-DL, and SSFSE-DLF images was significantly lower (P < 0.05), significantly higher (P < 0.05), and equivalent, respectively. The SSFSE-DL images exhibited significantly lower contrast between the junctional zone and myometrium than those obtained with the other sequences (P < 0.05). In qualitative comparisons with the PROPELLER images, all 3 SSFSE sequences, SSFSE-DL, and SSFSE-DLF demonstrated significantly higher scores for artifacts, noise, and sharpness, respectively (P < 0.01). The overall image quality of SSFSE-C (mean AUCVGC, 0.03; P < 0.01) and SSFSE-DL (mean AUCVGC, 0.23; P < 0.01) was rated as significantly inferior, whereas that of SSFSE-DLF (mean AUCVGC, 0.69) was equivalent or significantly higher (P < 0.01). CONCLUSION: Using a combination of DL and a sharpening filter markedly increases the image quality of SSFSE of the uterus to the level of the PROPELLER sequence.


Assuntos
Aprendizado Profundo , Artefatos , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Pelve , Útero/diagnóstico por imagem
20.
Eur J Radiol ; 150: 110271, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35334243

RESUMO

PURPOSE: A newly developed Adaptive Image Receive (AIR) coil is designed to be more flexible to conform to the human body habitus, and may improve image quality by reducing the distance between the coil element and the imaging subject. This study evaluated the AIR coil's usefulness for liver MR imaging at 3.0 T in comparison with that of a conventional coil retrospectively. METHOD: The study population comprised 50 consecutive patients, who underwent follow-up liver MR examinations with a 3.0-T MR system using both an AIR coil and a conventional coil to evaluate hepatocellular carcinoma. Three-dimensional fat-suppressed T1-weighted gradient-echo images before and after injection of an MRI contrast agent, T2-weighted single-shot fast spin-echo (SSFSE) images, and diffusion-weighted (DW) images obtained with the AIR coil were compared with corresponding images obtained with the conventional coil. One radiologist measured signal-to-noise ratios (SNRs), while two other radiologists used a 3-point scale to independently assess subjective image noise, artifacts, signal uniformity, and overall image quality. RESULTS: SNRs for the AIR coil were significantly higher than those for the conventional coil (P <.05). Subjective image noise for the AIR coil on pre- and postcontrast T1-weighted and DW images was lower than for the conventional coil for both readers (P <.05). Overall image quality on pre- and postcontrast T1-weighted and DW images for the AIR coil was better than that for the conventional coil for at least one reader (P <.05). CONCLUSIONS: In comparison with the conventional coil, AIR coil improved SNR and image quality of liver MR imaging.


Assuntos
Neoplasias Hepáticas , Imageamento por Ressonância Magnética , Humanos , Aumento da Imagem/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Estudos Retrospectivos , Tecnologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA