Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
J Infect Chemother ; 29(8): 825-828, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37187412

RESUMO

The promising diagnostic performance of rapid antigen tests (RATs) using non-invasive anterior nasal (AN) swab specimens to diagnose COVID-19 has been reported. A large number of RATs are commercially available; however, the careful assessment of RATs is essential prior to their implementation in clinical practice. We evaluated the clinical performance of the GLINE-2019-nCoV Ag Kit as a RAT using AN swabs in a prospective, blinded study. Adult patients who visited outpatient departments and received SARS-CoV-2 tests between August 16 and September 8, 2022, were eligible for this study. Patients who were aged under 18 years and patients without appropriate specimens were excluded. Two sets of AN and nasopharyngeal (NP) swabs were collected from all patients. Each set of specimens was tested by the RAT and quantitative reverse-transcription polymerase chain reaction (RT-qPCR). Of the 138 recruited patients, 84 were positive and 54 were negative by RT-qPCR using NP swabs. The positive agreement rate between RT-qPCR using NP swabs and RAT using AN swabs was 78.6% (95% confidence interval [CI], 68.3%-86.8%), the negative agreement rate was 98.1% (95% CI, 90.1%-99.9%), and the overall agreement rate was 86.2% (95% CI, 79.3%-91.5%), with a κ coefficient of 0.73. The positive agreement rate in the early phase (≤3 days from symptom onset) was >80%, but this fell to 50% in the late phase (≥4 days). This study demonstrates that the GLINE-2019-nCoV Ag Kit using AN swabs has good clinical performance and might be a reliable alternative method for diagnosing COVID-19.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , COVID-19/diagnóstico , Cavidade Nasal , Estudos Prospectivos , Testes Imunológicos , Nasofaringe , Sensibilidade e Especificidade
2.
J Infect Chemother ; 29(6): 586-591, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36849098

RESUMO

BACKGROUND: In the context of the coronavirus disease 2019 (COVID-19) pandemic, a rapid and reliable point-of-care test is an essential tool for controlling the spread of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). In particular, an immunochromatography test (ICT) that uses saliva specimens for rapid antigen detection not only reduces the risk of secondary infections but also reduces the burden on medical personnel. METHODS: The newly developed salivary antigen test kit "Inspecter Kowa® SARS-CoV-2" is an ICT to which saliva specimens can be directly applied. We evaluated its usefulness in comparison with reverse transcription quantitative PCR (RT-qPCR) and the Espline® SARS-CoV-2 Kit for the detection of SARS-CoV-2 using nasopharyngeal swab specimens. In this study, 140 patients with suspected symptomatic COVID-19 who visited our hospital were enrolled, and nasopharyngeal swab and saliva specimens were collected after they consented to participate in the study. RESULTS: Inspector Kowa SARS-CoV-2 was positive in 45 of 61 (73.8%) saliva that were positive by RT-qPCR and the Espline® SARS-CoV-2 Kit was also positive in 56 of 60 (93.3%) Np swabs that were positive by RT-qPCR. Good antigen detection was achieved by ICT with saliva and nasopharyngeal swab specimens when viral load was ≥105 copies/mL, whereas detection sensitivity was low when viral load was <105 copies/mL, especially in saliva specimens. CONCLUSION: This ICT for the detection of SARS-CoV-2 salivary antigen is an attractive tool that does not require specialized equipment and allows patients to perform the entire process from sample collection to self-diagnose and to reduce the burden on medical care during a pandemic.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , COVID-19/diagnóstico , Teste para COVID-19 , Saliva , Técnicas de Laboratório Clínico/métodos , Manejo de Espécimes/métodos , Nasofaringe
3.
Anal Chem ; 94(10): 4218-4226, 2022 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-35238540

RESUMO

The most common diagnostic method used for coronavirus disease-2019 (COVID-19) is real-time reverse transcription polymerase chain reaction (PCR). However, it requires complex and labor-intensive procedures and involves excessive positive results derived from viral debris. We developed a method for the direct detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in nasopharyngeal swabs, which uses matrix-assisted laser desorption and ionization time-of-flight mass spectrometry (MALDI-ToF MS) to identify specific peptides from the SARS-CoV-2 nucleocapsid phosphoprotein (NP). SARS-CoV-2 viral particles were separated from biological molecules in nasopharyngeal swabs by an ultrafiltration cartridge. Further purification was performed by an anion exchange resin, and purified NP was digested into peptides using trypsin. The peptides from SARS-CoV-2 that were inoculated into nasopharyngeal swabs were detected by MALDI-ToF MS, and the limit of detection was 106.7 viral copies. This value equates to 107.9 viral copies per swab and is approximately equivalent to the viral load of contagious patients. Seven NP-derived peptides were selected as the target molecules for the detection of SARS-CoV-2 in clinical specimens. The method detected between two and seven NP-derived peptides in 19 nasopharyngeal swab specimens from contagious COVID-19 patients. These peptides were not detected in four specimens in which SARS-CoV-2 RNA was not detected by PCR. Mutated NP-derived peptides were found in some specimens, and their patterns of amino acid replacement were estimated by accurate mass. Our results provide evidence that the developed MALDI-ToF MS-based method in a combination of straightforward purification steps and a rapid detection step directly detect SARS-CoV-2-specific peptides in nasopharyngeal swabs and can be a reliable high-throughput diagnostic method for COVID-19.


Assuntos
COVID-19 , SARS-CoV-2 , COVID-19/diagnóstico , Humanos , Lasers , Nasofaringe , RNA Viral/genética , Manejo de Espécimes/métodos , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos
4.
Int J Mol Sci ; 23(5)2022 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-35269748

RESUMO

BACKGROUND: Very few papers covering the anticancer activity of azulenes have been reported, as compared with those of antibacterial and anti-inflammatory activity. This led us to investigate the antitumor potential of fifteen 4,6,8-trimethyl azulene amide derivatives against oral malignant cells. METHODS: 4,6,8-Trimethyl azulene amide derivatives were newly synthesized. Anticancer activity was evaluated by tumor-specificity against four human oral squamous cell carcinoma (OSCC) cell lines over three normal oral cells. Neurotoxicity was evaluated by cytotoxicity against three neuronal cell lines over normal oral cells. Apoptosis induction was evaluated by Western blot and cell cycle analyses. RESULTS: Among fifteen derivatives, compounds 7, 9, and 15 showed the highest anticancer activity, and relatively lower neurotoxicity than doxorubicin, 5-fluorouracil (5-FU), and melphalan. They induced the accumulation of a comparable amount of a subG1 population, but slightly lower extent of caspase activation, as compared with actinomycin D, used as an apoptosis inducer. The quantitative structure-activity relationship analysis suggests the significant correlation of tumor-specificity with a 3D shape of molecules, and possible involvement of inflammation and hormone receptor response pathways. CONCLUSIONS: Compounds 7 and 15 can be potential candidates of a lead compound for developing novel anticancer drugs.


Assuntos
Antineoplásicos , Carcinoma de Células Escamosas , Neoplasias Bucais , Síndromes Neurotóxicas , Amidas/farmacologia , Amidas/uso terapêutico , Antineoplásicos/farmacologia , Antineoplásicos/uso terapêutico , Apoptose , Azulenos , Carcinoma de Células Escamosas/patologia , Linhagem Celular Tumoral , Proliferação de Células , Ensaios de Seleção de Medicamentos Antitumorais , Humanos , Estrutura Molecular , Neoplasias Bucais/patologia , Receptores Citoplasmáticos e Nucleares
5.
J Med Virol ; 93(12): 6778-6781, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34170555

RESUMO

A high-throughput, fully automated antigen detection test for SARS-CoV-2 is a viable alternative to reverse-transcription polymerase chain reaction (RT-qPCR) for mass screening during outbreaks. In this study, we compared RT-qPCR for viral load and the VITROS® SARS-CoV-2 Antigen Test with reference to the results of the LUMIPULSE® SARS-CoV-2 Ag Test. Of 128 nasopharyngeal swab specimens taken from patients suspected of being infected with SARS-CoV-2, 49 were positive and 79 were negative according to RT-qPCR. Consistent dose-dependent detection with VITROS® assay was successfully achieved when using nasopharyngeal swab specimens with Ct values of 32.0 or lesser, whereas the CLEIA-based LUMIPULSE® assay was able to detect lower viral loads compared with the VITROS® assay. Our results show that the performance of the VITROS® assay was satisfactory for the diagnosis of contagious COVID-19 patients in the clinical setting. Highlights The performance of the VITROS® SARS-CoV-2 Antigen Test was sufficient for the diagnosis of contagious COVID-19. This test showed high sensitivity and specificity in the detection of SARS-CoV-2 in samples with a Ct value of 32 or less.


Assuntos
Teste Sorológico para COVID-19/métodos , Teste para COVID-19/métodos , COVID-19/diagnóstico , COVID-19/imunologia , Técnicas Imunoenzimáticas/métodos , Testes Imunológicos/métodos , SARS-CoV-2/imunologia , Antígenos Virais/genética , Antígenos Virais/imunologia , COVID-19/virologia , Humanos , Programas de Rastreamento/métodos , Nasofaringe/imunologia , Nasofaringe/virologia , RNA Viral/genética , RNA Viral/imunologia , Reação em Cadeia da Polimerase em Tempo Real/métodos , SARS-CoV-2/genética , Sensibilidade e Especificidade , Carga Viral/genética , Carga Viral/imunologia
7.
Diagn Microbiol Infect Dis ; 100(3): 115370, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33744623

RESUMO

Several automated high-throughput immunoassays for detecting anti-SARS-CoV-2 antibodies by a semi-quantitative approach have been commercialized. In this study, we describe the timeline of the antibody response in patients with RT-PCR-confirmed COVID-19. A total of 292 sequential serum samples from 33 Japanese patients were retrospectively analyzed using four test kits for SARS-CoV-2: the Abbott SARS-CoV-2 IgG assay (Abbott), Elecsys® Anti-SARS-CoV-2 assay (Roche Diagnostic), and VITROS® Anti-SARS-CoV-2 Total and IgG assays (Ortho Clinical Diagnostics). All automated immunoassays could equivalently identify positive sera collected within 2 weeks after symptom onset (99.3%-100%). In addition, the S protein-based automated immunoassay, the VITROS® Anti-SARS-CoV-2 Total assay, may play a complementary role in evaluating passive antibody therapies or vaccines against SARS-CoV-2, although further research is required.


Assuntos
Anticorpos Antivirais/sangue , Teste Sorológico para COVID-19/métodos , COVID-19/diagnóstico , SARS-CoV-2/imunologia , Adulto , Idoso , COVID-19/imunologia , Feminino , Ensaios de Triagem em Larga Escala , Humanos , Imunoensaio , Cinética , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , SARS-CoV-2/isolamento & purificação , Sensibilidade e Especificidade
8.
Bone ; 138: 115469, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32512165

RESUMO

The human ACVR1 gene encodes a transmembrane protein consisting of 509 amino acids called activin A receptor, type I (ACVR1) or activin receptor-like kinase 2 (ALK2) and has nine coding exons. The ALK2 protein functions as a signaling receptor for ligands of the transforming growth factor-ß family. In the human ACVR1 gene, approximately 20 types of heterozygotic mutations in the coding exons have been associated with congenital disorders and somatic cancer, such as fibrodysplasia ossificans progressiva (FOP), diffuse intrinsic pontine glioma, diffuse idiopathic skeletal hyperostosis and some congenital heart disorders. In the present study, we designed primers for direct sequencing of the nine coding exons in the human ACVR1 gene. The reliability of the primers was examined by PCR and DNA sequencing using genomic DNA prepared from peripheral blood or swab samples of three patients with FOP who had different mutations in the ACVR1 gene. A single nucleotide heterozygotic mutation was identified in each genomic sample without additional mutations in other regions. Therefore, the primers designed for the nine coding exons of the ACVR1 gene could be useful for the genetic diagnosis of patients who may have disorders associated with mutations in the ACVR1 gene.


Assuntos
Receptores de Ativinas Tipo I , Primers do DNA , Éxons , Miosite Ossificante , Receptores de Ativinas Tipo I/genética , Heterozigoto , Humanos , Mutação/genética , Miosite Ossificante/genética , Reprodutibilidade dos Testes , Análise de Sequência de DNA
9.
J Clin Virol ; 129: 104446, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32512376

RESUMO

With the rapid spread of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), there is an urgent need for more rapid and simple detection technologies at the forefront of medical care worldwide. In this study, we evaluated the effectiveness of the Loopamp® 2019-SARSCoV-2 Detection Reagent Kit, which uses loop-mediated isothermal amplification (LAMP) technology. In this protocol, cDNA is synthesized from SARS-CoV-2 RNA using reverse transcriptase, followed by DNA amplification under isothermal conditions in one step. The RT-LAMP test kit amplified the targeted RNA of a SARS-CoV-2 isolate with a detection limit of 1.0 × 101 copies/µL, which was comparable to the detection sensitivity of quantitative reverse transcription PCR (RT-qPCR). Comparison with the results of RT-qPCR for 76 nasopharyngeal swab samples from patients with suspected COVID-19 showed a sensitivity of 100 % and a specificity of 97.6 %. In the 24 RNA specimens derived from febrile Japanese patients with or without influenza A, no amplification was observed using RT-LAMP. RT-LAMP could be a simple and easy-to-use diagnostic tool for the detection of SARS-CoV-2.


Assuntos
Betacoronavirus/isolamento & purificação , Técnicas de Laboratório Clínico/métodos , Infecções por Coronavirus/diagnóstico , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Amplificação de Ácido Nucleico/métodos , Pneumonia Viral/diagnóstico , Betacoronavirus/genética , COVID-19 , Teste para COVID-19 , Humanos , Japão , Pandemias , SARS-CoV-2 , Sensibilidade e Especificidade , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA