Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Int Ophthalmol ; 44(1): 243, 2024 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-38904834

RESUMO

PURPOSE: To describe the outcomes of double implantation of Xen 45 Gel Stent (Xen) using an ab externo approach with closed conjunctiva. METHODS: Retrospective single-centre case series of primary open-angle glaucoma patients with at least six months of follow-up after implantation of a second Xen in the same eye via ab externo technique without conjunctival opening. RESULTS: Eight pseudophakic eyes of 8 patients were included. Intraocular pressure (IOP) dropped from 30 ± 2.6 mmHg pre-operatively to 22.4 ± 2.3 mmHg one month after the first Xen implant (mean difference: -7.6 mmHg [95% confidence interval: -9.4, -5.9 mmHg], p = 0.0092). A second Xen was then implanted to achieve the target IOP. The procedure showed no significant intraoperative or postoperative complications. The IOP dropped to 16.1 ± 2.7 mmHg six months following this second implant (mean difference: -6.3 mmHg [95% confidence interval: -7.2, -5.3 mmHg], p = 0.0183); however, 3 patients needed medical therapy to further reduce the IOP towards the target value. CONCLUSION: Sequential implantation of two Xen 45 Gel Stents using an ab externo approach with closed conjunctiva appears a promising procedure that showed a favorable safety and efficacy profile in this small case series. This pilot data might pave the way for further studies to evaluate the safety and efficacy of the procedure.


Assuntos
Implantes para Drenagem de Glaucoma , Glaucoma de Ângulo Aberto , Pressão Intraocular , Desenho de Prótese , Stents , Humanos , Glaucoma de Ângulo Aberto/cirurgia , Glaucoma de Ângulo Aberto/fisiopatologia , Projetos Piloto , Masculino , Feminino , Estudos Retrospectivos , Pressão Intraocular/fisiologia , Idoso , Pessoa de Meia-Idade , Seguimentos , Resultado do Tratamento , Implantação de Prótese/métodos , Idoso de 80 Anos ou mais , Acuidade Visual
2.
Eur J Ophthalmol ; : 11206721241246187, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38644806

RESUMO

PURPOSE: To describe and validate a 3D-printed adapter tool which could be used with either a slit lamp or a condensing lens, interchangeable between devices through magnetic fastening, in order to provide physicians a quick, easy and effective method of obtaining clinical photos. MATERIALS AND METHODS: Three specialists, with at least 4-year experience in ophthalmology, gave a rate of image quality obtained by our device and the diagnostic confidence grade. The 3 specialists conducted each 13 or 14 examinations with the smartphone and magnetic adapter. At the end of evaluation, they rated with the Likert scale the ease of use of the device in obtaining clinical images of the anterior segment and ocular fundus respectively. RESULTS: Data of quality perception and confidence demonstrated high values not dissimilar to the "de visu" eye examination. Moreover the instrument we designed turned out to be very user friendly. CONCLUSION: Our adapter coupled with a modern smartphone was able to obtain 4k images and videos of anterior segment, central and peripheral fundus, in an easy and inexpensive way.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA