1.
Catheter Cardiovasc Interv ; 99(3): 699-705, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34132465

RESUMO

OBJECTIVES: To describe a novel technique for ostial stent placement using real-time IVUS guidance. BACKGROUND: Accurate placement of coronary stents at ostial locations is challenging with the true ostium frequently being missed increasing the risk of adverse events. We have developed a novel technique for ostial stent placement and report our benchtop testing and initial clinical experience. METHODS: Benchtop testing was performed to validate the appearance of the stent and delivery system on IVUS. Benchtop testing of real-time IVUS guided ostial stent positioning was carried out in a left main bifurcation phantom. Real-time IVUS guidance of stent placement in aorto-ostial, ostial left anterior descending (LAD), or ostial circumflex lesions was assessed in a prospective registry. RESULTS: Bench model IVUS demonstrated clear differences between the appearances of the stent and other components of the delivery system. Positioning of 10 consecutive stents into the ostial LAD using real-time IVUS guidance was assessed in a left main bifurcation model. Median distance from proximal stent edge to LAD ostium was 0.39 mm (interquartile range 0.31 to 0.73). Real-time IVUS guidance of ostial stent placement was performed in 50 patients (51 lesions). Angiographic success was 100%. IVUS post-stenting demonstrated median distance from the proximal stent edge to the ostium was 0.2 mm (interquartile range 0.1 to 0.5 mm). There was one periprocedural myocardial infarction but no other major adverse cardiac events at 30-days. CONCLUSIONS: We have developed a novel technique using real-time IVUS guidance allowing accurate ostial stent placement.


Assuntos
Doença da Artéria Coronariana , Infarto do Miocárdio , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Humanos , Stents , Resultado do Tratamento , Ultrassonografia de Intervenção/métodos
2.
Catheter Cardiovasc Interv ; 96(1): 31-39, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32087046

RESUMO

OBJECTIVES: In a coronary bifurcation bench model, to determine the effects of side branch (SB) wire crossing position and balloon position on the stent scaffolding after the final proximal optimization technique (POT). BACKGROUND: POT performed as a final step after SB dilatation or kissing balloon inflation (KBI) has been widely advocated despite limited evidence. METHODS: Thirty-one stent implantations in bifurcation phantoms were performed using a one-stent provisional technique with (KBI) (n = 13), with POT-side-POT technique (n = 12) or with the two-stent culotte technique (n = 6). SB wiring was performed through either a proximal or a distal stent cell and confirmed by optical coherence tomography. Final POT was performed with the balloon positioned either across or proximal to the SB takeoff. The area of the opened stent cell in front of the SB was assessed by 3D reconstructed microcomputation tomography scans performed before and after Final POT. RESULTS: In cases with metallic carina, final POT across the SB takeoff caused SB rejailing. Regardless of stent technique and wire position, a Final POT across the SB takeoff reduced the SB cell opening area by 43% [32%;58%] (n = 15). The largest reduction (54-70%) was found after the POT-side-POT technique in procedures with a proximal wiring. Final POT performed proximal to the SB takeoff caused limited or no SB cell opening area reduction (4% [0.6%;6%] [n = 16]). CONCLUSION: Final POT with balloon positioned across the SB takeoff in a narrow angle bifurcation reduces largest stent cell area in front of the SB ostium and may cause SB rejailing in cases with metallic carina.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Vasos Coronários , Stents Farmacológicos , Angioplastia Coronária com Balão/efeitos adversos , Vasos Coronários/diagnóstico por imagem , Humanos , Teste de Materiais , Modelos Anatômicos , Modelos Cardiovasculares , Desenho de Prótese
3.
Catheter Cardiovasc Interv ; 96(7): E674-E682, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-31710149

RESUMO

OBJECTIVES: To compare on the bench the physical and mechanical properties of Magmaris, a magnesium bioresorbable scaffold (BRS), with Absorb and DESolve polymeric BRS and a permanent metallic stent. BACKGROUND: Understanding the mechanical and physical properties of BRS is crucial for appropriate implantation and postdilatation. METHODS: Testing was performed in fluid at 37°C and in silicone bifurcation phantoms with a 30° angle between main branch (MB) and side branch. RESULTS: The 3.0-mm Magmaris BRS did not fracture after MB postdilatation up to 4.4 mm in contrast to the Absorb where the safe postdilatation diameter was 3.7 mm. For dilatation through stent cells, there were no Magmaris fractures with 3.0-mm noncompliant (NC) balloons inflated to nominal pressure. Mini-kissing balloon postdilatation with two 3.0-mm NC balloons up to 17 atm was without fracture except for an outlier. Longitudinal and radial strengths were similar for Magmaris and Absorb BRS. The crossing profile for the Magmaris was larger than other devices. Recoil 120 min after deployment was the greatest for Magmaris but 120 min after 3.5 mm postdilatation all devices had similar diameters. CONCLUSIONS: The Magmaris BRS was more resistant to strut fracture than Absorb. It had a larger crossing profile than other devices and similar radial and longitudinal strengths to Absorb. While recoil after deployment was greater with Magmaris, 120 min after 3.5 mm postdilatation all devices had similar diameters.


Assuntos
Implantes Absorvíveis , Angioplastia Coronária com Balão/instrumentação , Fármacos Cardiovasculares/administração & dosagem , Materiais Revestidos Biocompatíveis , Stents Farmacológicos , Magnésio , Angioplastia Coronária com Balão/efeitos adversos , Análise de Falha de Equipamento , Teste de Materiais , Desenho de Prótese , Falha de Prótese , Estresse Mecânico
4.
Catheter Cardiovasc Interv ; 92(5): 883-889, 2018 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-29219238

RESUMO

OBJECTIVES: To confirm clinically that coronary balloon catheter tips may be damaged during bifurcation treatment with side-branch access through the side of a stent. On the bench, we aimed to assess the susceptibility of different balloon designs to damage. We compared catheter tip widths. We tested whether balloon tip flaring can cause stent distortion. BACKGROUND: We had observed that balloon catheters that failed to cross to a side-branch frequently exhibited tip damage. METHODS AND RESULTS: We examined microscopically for damage 82 balloon tips after clinical side-branch access. In a bench study, the forces required to compress catheter tips 0.5 mm were compared to assess susceptibility to damage. We compared tip widths of balloons of different nominal inflation diameters. We examined stents after side-branch access for distortion. In 42 of 48 (88%) of balloon tips from patients with resistance to or failure to cross through the side of a stent there was tip damage. Even when the balloon crossed without perceptible resistance, tip damage occurred in over half of balloons 18/34 (53%). Some balloon designs were more resistant to damage than others. Tips from balloons of different nominal diameters from the same manufacturer had the same width. Stent distortion caused by damaged balloon tips is improved by kissing balloon post-dilatation. CONCLUSIONS: Balloon tip damage is common with crossing between stent struts. This is one cause of failure of a balloon to access a side-branch and a new balloon should be used. If stent distortion is suspected, it should be corrected with kissing balloon post-dilatation.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Cateterismo Cardíaco/instrumentação , Cateteres Cardíacos , Doença da Artéria Coronariana/terapia , Falha de Equipamento , Stents , Angioplastia Coronária com Balão/efeitos adversos , Cateterismo Cardíaco/efeitos adversos , Doença da Artéria Coronariana/fisiopatologia , Desenho de Equipamento , Humanos , Teste de Materiais , Fatores de Risco
5.
J Magn Reson Imaging ; 44(4): 983-92, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27042817

RESUMO

PURPOSE: To examine the feasibility of combining computational fluid dynamics (CFD) and dynamically scaled phantom phase-contrast magnetic resonance imaging (PC-MRI) for coronary flow assessment. MATERIALS AND METHODS: Left main coronary bifurcations segmented from computed tomography with bifurcation angles of 33°, 68°, and 117° were scaled-up ∼7× and 3D printed. Steady coronary flow was reproduced in these phantoms using the principle of dynamic similarity to preserve the true-scale Reynolds number, using blood analog fluid and a pump circuit in a 3T MRI scanner. After PC-MRI acquisition, the data were segmented and coregistered to CFD simulations of identical, but true-scale geometries. Velocities at the inlet region were extracted from the PC-MRI to define the CFD inlet boundary condition. RESULTS: The PC-MRI and CFD flow data agreed well, and comparison showed: 1) small velocity magnitude discrepancies (2-8%); 2) with a Spearman's rank correlation ≥0.72; and 3) a velocity vector correlation (including direction) of r(2) ≥ 0.82. The highest agreement was achieved for high velocity regions with discrepancies being located in slow or recirculating zones with low MRI signal-to-noise ratio (SNRv ) in tortuous segments and large bifurcating vessels. CONCLUSION: Characterization of coronary flow using a dynamically scaled PC-MRI phantom flow is feasible and provides higher resolution than current in vivo or true-scale in vitro methods, and may be used to provide boundary conditions for true-scale CFD simulations. J. MAGN. RESON. IMAGING 2016;44:983-992.


Assuntos
Velocidade do Fluxo Sanguíneo/fisiologia , Circulação Coronária/fisiologia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/fisiologia , Angiografia por Ressonância Magnética/instrumentação , Modelos Cardiovasculares , Imagens de Fantasmas , Simulação por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Angiografia por Ressonância Magnética/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
6.
Catheter Cardiovasc Interv ; 86(7): 1141-50, 2015 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-25044635

RESUMO

OBJECTIVES: We studied coronary vasomotion in patients treated with the Mistent(®) absorbable polymer sirolimus-eluting stent (APSES) and in patients implanted with the Endeavor(®) zotarolimus-eluting stent (ZES). BACKGROUND: First generation (1st-gen) drug-eluting stents (DES) induce persistent vasomotor dysfunction in the treated coronary artery. It is unknown whether and to what extent the implantation of an absorbable polymer DES impairs coronary vasomotion. METHODS: This sub-study of the DESSOLVE II trial included 19 APSES Mistent(®) and 10 ZES Endeavor(®) patients. Incremental atrial pacing and quantitative coronary angiography were used to assess vasomotion proximal and distal to the stent and in a reference segment at 9 months after implantation. Percent changes in vessel diameter with pacing versus baseline were calculated and compared. Vasomotor response of the APSES group was also compared with changes observed in a historical group of 17 patients implanted with a 1st-gen sirolimus-eluting stent (SES). RESULTS: Normal vasomotion (vasodilatation) was preserved and of comparable magnitude in the APSES and in the ZES group both proximally (P = 0.34) and distally (P = 0.38) to the stent. This finding was not observed in the 1st-gen SES group showing marked pacing-induced vasoconstriction at both stent edges (P < 0.05 vs. APSES). The results were practically unchanged after excluding patients with absolute changes in vessel diameter <3% between baseline and maximal pacing. CONCLUSIONS: The implantation of an absorbable polymer sirolimus-eluting stent is associated with preserved coronary vasomotion, comparable to that observed after implantation of the Endeavor(®) ZES, and distinct from 1st-gen SES which induce coronary vasomotor dysfunction.


Assuntos
Implantes Absorvíveis , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Vasos Coronários/fisiopatologia , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Polímeros , Sirolimo/administração & dosagem , Vasodilatação , Idoso , Estimulação Cardíaca Artificial , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/fisiopatologia , Vasos Coronários/diagnóstico por imagem , Europa (Continente) , Feminino , Estudo Historicamente Controlado , Humanos , Masculino , Pessoa de Meia-Idade , Nova Zelândia , Intervenção Coronária Percutânea/efeitos adversos , Estudos Prospectivos , Método Simples-Cego , Sirolimo/análogos & derivados , Fatores de Tempo , Resultado do Tratamento , Vasoconstrição
8.
J Interv Cardiol ; 26(1): 49-57, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22988961

RESUMO

OBJECTIVES: To assess the influence of race on long-term outcomes following percutaneous coronary intervention (PCI) with paclitaxel-eluting stents (PES). BACKGROUND: Data on the influence of race on long-term outcomes following PCI with drug-eluting stents are limited because of severe underrepresentation of minority populations in randomized trials. METHODS: We compared 5-year outcomes of 2,301 whites, 127 blacks, and 169 Asians treated with PES in the TAXUS IV, V, and ATLAS trials. Outcomes were adjusted using a propensity score logistic regression model with 1:4 matching. RESULTS: Blacks were more likely than whites to be female, have a history of hypertension, diabetes mellitus, congestive heart failure, and stroke, but were less likely to have prior coronary artery disease. Compared with whites, Asians were younger, more likely to be male, have stable angina, and left anterior descending disease, and less likely to have silent ischemia, previous coronary artery bypass surgery, prior coronary artery disease, diabetes mellitus, peripheral vascular disease, and to receive glycoprotein IIb/IIIa inhibitors. Despite higher antiplatelet compliance, the adjusted 5-year rates of myocardial infarction (15.4% vs. 5.4%, P < 0.001) and stent thrombosis (5.6% vs. 1.1%, P = 0.002) were higher in blacks than whites. Despite lower antiplatelet compliance, Asians had no differences in myocardial infarction and stent thrombosis compared with whites. Mortality and revascularization rates were similar between the three groups. CONCLUSIONS: The long-term risk of major thrombotic events after PCI with PES was higher in blacks, but not Asians, compared with whites. The mechanisms underlying these racial differences warrant further investigation.


Assuntos
Cardiotônicos/administração & dosagem , Stents Farmacológicos , Paclitaxel/administração & dosagem , Intervenção Coronária Percutânea , Grupos Raciais/estatística & dados numéricos , Feminino , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/epidemiologia , Ensaios Clínicos Controlados Aleatórios como Assunto , Trombose/epidemiologia
9.
Eur Heart J ; 33(11): 1325-33, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22507972

RESUMO

AIMS: To analyse the vasoreactivity of a coronary segment, previously scaffolded by the ABSORB bioresorbable vascular scaffold (BVS) device, in relationship to its intravascular ultrasound-virtual histology (IVUS-VH) composition and reduction in greyscale echogenicity of the struts. Coronary segments, transiently scaffolded by a polymeric device, may in the long-term recover a normal vasomotor tone. Recovery of a normal endothelial-dependent vasomotion may be enabled by scaffold bioresorption, composition of the underlying tissue, or a combination of both mechanisms. METHODS AND RESULTS: All patients from the ABSORB Cohort A and B trials, who underwent a vasomotion test and IVUS-VH investigation at 12 and 24 months, were included. Acetylcholine (Ach) and nitroglycerin were used to test either the endothelial-dependent or -independent vasomotion of the treated segment. Changes in polymeric strut echogenicity-a surrogate for bioresorption-IVUS-VH composition of the tissue underneath the scaffold and their relationship with the pharmacologically induced vasomotion were all evaluated. Overall, 26 patients underwent the vasomotion test (18 at 12 and 8 at 24 months). Vasodilatory response to Ach was quantitatively associated with larger reductions over time in polymeric strut echogenicity (y= -0.159x- 6.85; r= -0.781, P< 0.001). Scaffolded segments with vasoconstriction to Ach had larger vessel areas (14.37 ± 2.50 vs. 11.85 ± 2.54 mm(2), P= 0.030), larger plaque burden (57.31 ± 5.96 vs. 49.09 ± 9.10%, P= 0.018), and larger necrotic core (NC) areas [1.39 (+1.14, +1.74) vs. 0.78 mm(2) (+0.20, +0.98), P= 0.006] compared with those with vasodilation. CONCLUSION: Vasodilatory response to Ach, in coronary segments scaffolded by the ABSORB BVS device, is associated with a reduction in echogenicity of the scaffold over time, and a low amount of NC. In particular, the latter finding resembles the behaviour of a native coronary artery not caged by an intracoronary device.


Assuntos
Vasos Coronários/fisiopatologia , Imunossupressores/administração & dosagem , Isquemia Miocárdica/patologia , Placa Aterosclerótica/patologia , Sirolimo/análogos & derivados , Vasodilatação , Implantes Absorvíveis , Acetilcolina/farmacologia , Idoso , Vasos Coronários/patologia , Stents Farmacológicos , Endotélio Vascular/patologia , Endotélio Vascular/fisiopatologia , Everolimo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/tratamento farmacológico , Isquemia Miocárdica/fisiopatologia , Nitroglicerina/farmacologia , Placa Aterosclerótica/fisiopatologia , Sirolimo/administração & dosagem , Alicerces Teciduais , Vasodilatação/efeitos dos fármacos , Vasodilatadores/farmacologia , Sistema Vasomotor/efeitos dos fármacos
10.
Catheter Cardiovasc Interv ; 79(2): 219-28, 2012 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-21563288

RESUMO

OBJECTIVE: To compare the geometrical parameters of a bioresorbable vascular scaffold (BVS) with a standard metallic stent. BACKGROUND: The introduction of polymeric bioresorbable materials in the design of novel coronary scaffolds may affect some geometrical parameters, such as eccentricity and symmetry indices, previously introduced as IVUS criteria for optimal metallic stent deployment. METHODS: From ABSORB Cohort A, ABSORB Cohort B, SPIRIT I, and SPIRIT II, all patients implanted with BVS 1.0, BVS 1.1, or XIENCE V, respectively and intravascular ultrasound analyses post-implantation were selected. The eccentricity index was calculated frame by frame and expressed as an average per device (minimum diameter/maximum diameter). The symmetry index of the device was reported as ([maximum diameter - minimum diameter]/maximum diameter). Six months major adverse cardiac events (MACE) were analyzed. RESULTS: A total of 242 patients were selected (BVS 1.0: n = 28, BVS 1.1: n = 94, XIENCE V: n = 120). The BVS exhibited a significantly lower eccentricity index (BVS 1.0: 0.83 ± 0.09; BVS 1.1: 0.85 ± 0.08; XIENCE V: 0.90 ± 0.06; P < 0.01) and a significantly higher symmetry index (BVS 1.0: 0.30 ± 0.07; BVS 1.1: 0.31 ± 0.06, XIENCE V 0.26 ± 0.07; P < 0.01) as compared to the XIENCE V. An inverse correlation was found between the symmetry and eccentricity indices for both (BVS r = -0.69, P < 0.01; XIENCE V r = -0.61, P < 0.01). No differences in MACE were detected between the groups according to their geometrical parameters. CONCLUSIONS: The introduction of a new polymeric material in the design of BVS resulted in a lower eccentricity index and a higher symmetry index as compared to metallic stents, without detectable impact in MACE, at 6 months.


Assuntos
Implantes Absorvíveis , Isquemia Miocárdica/cirurgia , Stents , Alicerces Teciduais , Angiografia Coronária , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/diagnóstico , Período Pós-Operatório , Estudos Prospectivos , Desenho de Prótese , Método Simples-Cego , Resultado do Tratamento , Ultrassonografia de Intervenção
11.
J Invasive Cardiol ; 34(5): E397-E407, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35451997

RESUMO

AIMS: Percutaneous coronary intervention with Y-stenting of coronary bifurcation disease is not commonly undertaken. The procedural and medium-term clinical outcomes of coronary bifurcation lesions treated with the proximal to distal Y stent technique by a single experienced operator were reviewed. METHODS: A total of 167 consecutive procedures using either provisional Y strategies or full-coverage options performed at Auckland City Hospital, New Zealand, between January 2013 and July 2018 were included in this retrospective observational study. All medical records and coronary angiograms were reviewed. RESULTS: Three-year clinical follow-up data were available in 162 of 167 patients. The primary endpoint, defined as the composite of cardiovascular death, spontaneous myocardial infarction (MI), target-lesion revascularization (TLR), target-vessel nontarget-lesion revascularization (nontarget-lesion TVR), and stent thrombosis (ST) occurred in 25 patients (15%) at 3 years. Secondary endpoints were all-cause mortality (12%), including cardiovascular mortality (6%), noncardiovascular mortality (4%), undetermined death (2%), spontaneous MI (7%), TLR (1%), nontarget-lesion TVR (0%), and ST (0.6%). CONCLUSIONS: The proximal to distal Y-stent technique is a widely applicable approach to bifurcation lesions, with good medium-term clinical outcomes when used in a heterogeneous group of clinical and anatomical scenarios. Complications related to the stented site were infrequent. Randomized, controlled trials are needed to assess its efficacy compared with other bifurcation interventional techniques.


Assuntos
Doença da Artéria Coronariana , Infarto do Miocárdio , Intervenção Coronária Percutânea , Trombose , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/cirurgia , Humanos , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/epidemiologia , Infarto do Miocárdio/etiologia , Intervenção Coronária Percutânea/métodos , Stents
12.
Circulation ; 122(22): 2301-12, 2010 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-21098436

RESUMO

BACKGROUND: The first generation of the bioresorbable everolimus drug-eluting vascular scaffold showed signs of shrinkage at 6 months, which largely contributed to late luminal loss. Nevertheless, late luminal loss was less than that observed with bare metal stents. To maintain the mechanical integrity of the device up to 6 months, the scaffold design and manufacturing process of its polymer were modified. METHODS AND RESULTS: Quantitative coronary angiography, intravascular ultrasound with analysis of radiofrequency backscattering, and as an optional assessment, optical coherence tomography (OCT) were performed at baseline and at a 6-month follow-up. Forty-five patients successfully received a single bioresorbable everolimus drug-eluting vascular scaffold. One patient had postprocedural release of myocardial enzyme without Q-wave occurrence; 1 patient with OCT-diagnosed disruption of the scaffold caused by excessive postdilatation was treated 1 month later with a metallic drug-eluting stent. At follow-up, 3 patients declined recatheterization, 42 patients had quantitative coronary angiography, 37 had quantitative intravascular ultrasound, and 25 had OCT. Quantitative coronary angiography disclosed 1 edge restenosis (1 of 42; in-segment binary restenosis, 2.4%). At variance with the ultrasonic changes seen with the first generation of bioresorbable everolimus drug-eluting vascular scaffold at 6 months, the backscattering of the polymeric struts did not decrease over time, the scaffold area was reduced by only 2.0% with intravascular ultrasound, and no change was noted with OCT. On an intention-to-treat basis, the late lumen loss amounted to 0.19±0.18 mm with a limited relative decrease in minimal luminal area of 5.4% on intravascular ultrasound. OCT showed at follow-up that 96.8% of the struts were covered and that malapposition of at least 1 strut, initially observed in 12 scaffolds, was detected at follow-up in only 3 scaffolds. Mean neointimal growth measured by OCT between and on top of the polymeric struts equaled 1.25 mm(2), or 16.6% of the scaffold area. CONCLUSION: Modified manufacturing process of the polymer and geometric changes in the polymeric platform have substantially improved the medium-term performance of this new generation of drug-eluting scaffold to become comparable to those of current drug eluting stents. CLINICAL TRIAL REGISTRATION: URL: http://clinicaltrials.gov. Unique identifier: NCT00856856.


Assuntos
Implantes Absorvíveis , Estenose Coronária/patologia , Estenose Coronária/terapia , Stents Farmacológicos , Sirolimo/análogos & derivados , Alicerces Teciduais , Idoso , Angiografia Coronária , Estenose Coronária/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Everolimo , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Polímeros , Estudos Retrospectivos , Fatores de Tempo , Tomografia de Coerência Óptica/métodos , Resultado do Tratamento , Ultrassonografia
14.
Catheter Cardiovasc Interv ; 78(1): 3-12, 2011 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-21413120

RESUMO

OBJECTIVES: The ABSORB cohort A trial using the bioresorbable everolimus-eluting scaffold (BVS revision 1.0, Abbott Vascular) demonstrated a slightly higher acute recoil with BVS than with metallic stents. To reinforce the mechanical strength of the scaffold, the new BVS scaffold (revision 1.1) with modified strut design was developed and tested in the ABSORB cohort B trial. This study sought to evaluate and compare the in vivo acute scaffold recoil of the BVS revision 1.0 in ABSORB cohort A and the BVS revision 1.1 in ABSORB cohort B with the historical recoil of the XIENCE V® everolimus-eluting metal stent (EES, SPIRIT I and II). METHODS: In the ABSORB cohort B trial, 101 patients with one or two de-novo lesions were enrolled at 10 sites. In ABSORB cohort A, 27 patients treated with a BVS 1.0 were analyzed and compared with EES. Acute absolute recoil, assessed by quantitative coronary angiography, was defined as the difference between mean diameter of the last inflated balloon at the highest pressure (X) and mean lumen diameter of the stent immediately after the last balloon deflation (Y). Acute percent recoil was defined as (X - Y)/X and expressed as a percentage. RESULTS: Out of 101 patients enrolled in the ABSORB cohort B trial, 88 patients are available for complete analysis of acute recoil. Absolute recoil of BVS 1.1 (0.19 ± 0.18 mm) was numerically higher than metallic EES (vs. 0.13 ± 0.21 mm) and similar to BVS 1.0 (0.20 ± 0.21 mm) but the differences did not reach statistical significance (P = 0.40). The acute percent recoil demonstrated the same trend (EES: 4.3% ± 7.1%, BVS 1.0: 6.9% ± 7.0%, BVS 1.1: 6.7% ± 6.4%, P = 0.22). In the multivariate regression model, high balloon/artery ratio (>1.1) (OR 1.91 [1.34-2.71]) was the predictive for high absolute recoil (>0.27 mm) while (larger) preprocedural MLD was protective (OR 0.84 [0.72-0.99]). The stent/scaffold type was not a predictor of acute recoil. CONCLUSIONS: The average in vivo acute scaffold recoil of the BVS 1.1 is slightly higher than the metallic EES. However, the scaffold/stent type was not predictive of high acute recoil, while implantation in undersized vessels or usage of oversized devices might confound the results.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Materiais Biocompatíveis , Fármacos Cardiovasculares/administração & dosagem , Estenose Coronária/terapia , Stents Farmacológicos , Metais , Sirolimo/análogos & derivados , Idoso , Austrália , Angiografia Coronária , Estenose Coronária/diagnóstico por imagem , Europa (Continente) , Everolimo , Feminino , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Nova Zelândia , Razão de Chances , Pressão , Desenho de Prótese , Sirolimo/administração & dosagem , Estresse Mecânico , Resultado do Tratamento
15.
Circ J ; 75(5): 1120-9, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21467655

RESUMO

BACKGROUND: The long-term impact of treating de novo coronary lesions in native vessels and challenging small vessel and long lesion subsets with TAXUS Liberté stents is unknown. This report examines the 3-year efficacy and safety from the TAXUS ATLAS program. METHODS AND RESULTS: TAXUS ATLAS WH, Small Vessel, and Long Lesion are non-randomized studies comparing TAXUS Liberté (n = 871), TAXUS Liberté 2.25 mm (n = 261), and TAXUS Liberté 38 mm (n = 150) stents, respectively, to case-matched TAXUS Express historical controls. TAXUS Liberté demonstrated comparable 3-year rates of major adverse cardiac events (19.0% vs. 20.2%, P = 0.51) in de novo lesions, reduced target lesion revascularization (TLR, 10.0% vs. 22.1%, P = 0.008) in small vessels, and reduced myocardial infarction (MI, 2.9% vs. 10.4%; P = 0.01) and stent thrombosis (ST, 0.0% vs. 3.9%, P = 0.03) in long lesions vs. TAXUS Express. After propensity score adjustment, no statistically significant effect of TAXUS Liberté on TLR (9.7% vs. 16.9%, P = 0.12) in small vessels or MI (2.9% vs. 7.9%, P = 0.05) in long lesions was noted, although reduced ST (0.0% vs. 2.7%, P = 0.02) remained in long lesions. Multivariate analyses demonstrated that TAXUS Liberté treatment significantly reduced TLR by 66% in small vessels, and MI by 75% in long lesions, vs. TAXUS Express. CONCLUSIONS: TAXUS Liberté suggests durable 3-year effectiveness in reducing restenosis and improved clinical outcomes in small vessels and long lesions compared with TAXUS Express.


Assuntos
Stents , Humanos , Taxus
16.
Curr Cardiol Rep ; 13(5): 424-31, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21728016

RESUMO

Coronary artery bypass grafting (CABG) has been considered the standard therapy for unprotected (nonrevascularized) left main coronary disease (ULM). However, increasing experience with ULM percutaneous coronary intervention (PCI) has resulted in high procedural success and favorable early and late clinical outcomes. In particular, reduction in clinical restenosis with drug-eluting stents, evolution of procedural technique, and demonstration of favorable outcomes from comparative trials with CABG have promoted consideration of PCI as an alternative revascularization strategy in selected patients with ULM disease. This review summarizes the results from comparative studies examining PCI versus CABG for ULM disease, discusses changing indications for ULM PCI and identifies outstanding issues that must be considered before further advancing treatment recommendations.


Assuntos
Ponte de Artéria Coronária/métodos , Doença da Artéria Coronariana/cirurgia , Stents Farmacológicos , Angiografia Coronária , Doença da Artéria Coronariana/patologia , Doença da Artéria Coronariana/fisiopatologia , Tomada de Decisões , Feminino , Humanos , Masculino , Seleção de Pacientes , Medição de Risco
17.
Lancet ; 373(9667): 897-910, 2009 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-19286089

RESUMO

BACKGROUND: Drug-eluting metallic coronary stents predispose to late stent thrombosis, prevent late lumen vessel enlargement, hinder surgical revascularisation, and impair imaging with multislice CT. We assessed the safety of the bioabsorbable everolimus-eluting stent (BVS). METHODS: 30 patients with a single de-novo coronary artery lesion were followed up for 2 years clinically and with multiple imaging methods: multislice CT, angiography, intravascular ultrasound, derived morphology parameters (virtual histology, palpography, and echogenicity), and optical coherence tomography (OCT). FINDINGS: Clinical data were obtained from 29 of 30 patients. At 2 years, the device was safe with no cardiac deaths, ischaemia-driven target lesion revascularisations, or stent thromboses recorded, and only one myocardial infarction (non-Q wave). 18-month multislice CT (assessed in 25 patients) showed a mean diameter stenosis of 19% (SD 9). At 2-year angiography, the in-stent late loss of 0.48 mm (SD 0.28) and the diameter stenosis of 27% (11) did not differ from the findings at 6 months. The luminal area enlargement on OCT and intravascular ultrasound between 6 months and 2 years was due to a decrease in plaque size without change in vessel size. At 2 years, 34.5% of strut locations presented no discernible features by OCT, confirming decreases in echogenicity and in radiofrequency backscattering; the remaining apparent struts were fully apposed. Additionally, vasomotion occurred at the stented site and adjacent coronary artery in response to vasoactive agents. INTERPRETATION: At 2 years after implantation the stent was bioabsorbed, had vasomotion restored and restenosis prevented, and was clinically safe, suggesting freedom from late thrombosis. Late luminal enlargement due to plaque reduction without vessel remodelling needs confirmation.


Assuntos
Implantes Absorvíveis , Doença das Coronárias/terapia , Reestenose Coronária/etiologia , Reestenose Coronária/prevenção & controle , Stents Farmacológicos/efeitos adversos , Imunossupressores , Sirolimo/análogos & derivados , Ensaios Clínicos como Assunto , Doença das Coronárias/diagnóstico por imagem , Everolimo , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Multicêntricos como Assunto , Resultado do Tratamento , Ultrassonografia
19.
Catheter Cardiovasc Interv ; 75(6): 914-8, 2010 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-20091822

RESUMO

BACKGROUND: In the ABSORB study cohort A the changes in the amount of dense calcium and necrotic core have not been reported in comparison to the prestenting phase; this evaluation could be useful to better clarify the bioabsorption process. Aim of this study was therefore to evaluate the dynamic changes in plaque size and plaque tissue composition observed between 6 months and 2 years follow-up, and to compare these findings to the prestenting phase. METHODS: Angiography, intravascular ultrasound and derived parameters (virtual histology, palpography, and echogenicity) were serially assessed postprocedure, at 6 months and at 2 years in 20 patients. In a subset of 8 patients the same measurements were also recorded in the prestenting phase. RESULTS: In the total population a reduction of 18% in the plaque area was observed between 6 month and 2 year follow-up (7.56 +/- 2.32 mm2 at 6 months vs. 6.16 +/- 2.10 mm2 at 2 year follow-up; P < 0.01). In the subgroup of eight patients who underwent IVUS during the pre-stenting phase, the plaque area at 2 year follow-up was not significantly different when compared to the prestenting plaque area (7.29 +/- 2.29 mm2 at prestenting vs. 7.48 +/- 1.45 mm2 at 2 year follow-up, P = NS). Necrotic core area was reduced by 24% between the 6 month and 2 year follow-up (0.97 +/- 0.66 mm2 at 6 months vs. 0.74 +/- 0.53 mm2 at 2 year follow-up; P = NS), whilst dense calcium was reduced by 14% from 6 month to 2 year follow-up (0.83 +/- 0.50 mm2 at 6 months vs 0.72 +/- 0.64 mm2 at 2 year follow-up; P = NS). Whilst the necrotic core at 2 years follow-up was not significantly different when compared to the pre-stenting phase (0.62 +/- 0.42 mm2 prestenting vs 1.07 +/- 0.56 mm2 at 2 year follow-up; P = NS), the area of dense calcium was significantly higher at follow-up compared to prestenting (0.35 +/- 0.35 mm2 pre-stenting vs. 0.84 +/- 0.66 mm2 at 2 year follow-up; P < 0.05). CONCLUSIONS: The reduction in the necrotic core component between 6 month and two year follow-up could be related to a synergistic effect of the bio-absorption process and the anti-inflammatory action of everolimus.


Assuntos
Angioplastia Coronária com Balão , Doença da Artéria Coronariana/terapia , Vasos Coronários/química , Stents Farmacológicos , Imunossupressores/administração & dosagem , Sirolimo/análogos & derivados , Ultrassonografia de Intervenção , Idoso , Cateterismo Cardíaco , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Everolimo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Necrose , Sirolimo/administração & dosagem
20.
Lancet ; 371(9616): 899-907, 2008 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-18342684

RESUMO

BACKGROUND: A fully bioabsorbable drug-eluting coronary stent that scaffolds the vessel wall when needed and then disappears once the acute recoil and constrictive remodelling processes have subsided has theoretical advantages. The bioasorbable everolimus-eluting stent (BVS) has a backbone of poly-L-lactic acid that provides the support and a coating of poly-D,L-lactic acid that contains and controls the release of the antiproliferative agent everolimus. We assessed the feasibility and safety of this BVS stent. METHODS: In this prospective, open-label study we enrolled 30 patients who had either stable, unstable, or silent ischaemia and a single de-novo lesion that was suitable for treatment with a single 3.0 x 12 mm or 3.0 x 18 mm stent. Patients were enrolled from four academic hospitals in Auckland, Rotterdam, Krakow, and Skejby. The composite endpoint was cardiac death, myocardial infarction, and ischaemia-driven target lesion revascularisation. Angiographic endpoints were available for 26 patients and intravascular-ultrasound endpoints for 24 patients. Clinical endpoints were assessed in all 30 patients at 6 and 12 months. In a subset of 13 patients, optical coherence tomography was undertaken at baseline and follow-up. Analysis was by intention to treat. This study is registered with ClinicalTrials.gov, number NCT00300131. FINDINGS: Procedural success was 100% (30/30 patients), and device success 94% (29/31 attempts at implantation of the stent). At 1 year, the rate of major adverse cardiac events was 3.3%, with only one patient having a non-Q wave myocardial infarction and no target lesion revascularisations. No late stent thromboses were recorded. At 6-month follow-up, the angiographic in-stent late loss was 0.44 (0.35) mm and was mainly due to a mild reduction of the stent area (-11.8%) as measured by intravascular ultrasound. The neointimal area was small (0.30 [SD 0.44] mm2), with a minimal area obstruction of 5.5%. INTERPRETATION: This study shows the feasibility of implantation of the bioabsorbable everolimus-eluting stent, with an acceptable in-stent late loss, minimal intrastent neointimal hyperplasia, and a low stent area obstruction. FUNDING: Abbott Vascular.


Assuntos
Doença das Coronárias/terapia , Stents Farmacológicos , Imunossupressores , Sirolimo/análogos & derivados , Implantes Absorvíveis , Angioplastia Coronária com Balão , Doença das Coronárias/diagnóstico por imagem , Reestenose Coronária , Everolimo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Segurança , Ultrassonografia