Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 67
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Opt Soc Am A Opt Image Sci Vis ; 41(4): 581-587, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38568658

RESUMO

This study investigates the just-noticeable difference (JND) in luminance below the 0.050c d/m 2 threshold not covered by the DICOM standard in medical imaging displays. A total of 21 healthy young adults were tested using an ultralow-luminance liquid crystal display at a viewing distance of 46 cm. The optotype featured a 4 cycle/deg rectangular wave-like stripe. The average percentage of correct responses for JND indices between -18 and 0 was 70.8%. Using the extended JND based on the Barten model that matches the current JND definition, we confirmed the JND at a very low luminance of 0.0500c d/m 2 or less. These findings suggest the feasibility of further refining the gradation differences in medical imaging displays.


Assuntos
Diagnóstico por Imagem , Adulto Jovem , Humanos , Limiar Diferencial
2.
Int J Mol Sci ; 25(6)2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38542305

RESUMO

We tested five chemically and metabolically stable prostaglandin (PG) receptor agonists in a mouse model of dexamethasone-induced ocular hypertension (OHT). Whilst all compounds significantly (p < 0.05, ANOVA) lowered intraocular pressure (IOP) after twice-daily bilateral topical ocular dosing (5 µg/dose) over three weeks, the time course and magnitude of the responses varied. The onset of action of NS-304 (IP-PG receptor agonist) and rivenprost (EP4-PG receptor agonist) was slower than that of misoprostol (mixed EP2/EP3/EP4-PG receptor agonist), PF-04217329 (EP2-PG receptor agonist), and butaprost (EP2-PG receptor agonist). The rank order of IOP-lowering efficacies aligned with the onset of actions of these compounds. Peak IOP reductions relative to vehicle controls were as follows: misoprostol (74.52%) = PF-04217329 (74.32%) > butaprost (65.2%) > rivenprost (58.4%) > NS-304 (55.3%). A literature survey indicated that few previously evaluated compounds (e.g., latanoprost, timolol, pilocarpine, brimonidine, dorzolamide, cromakalim analog (CKLP1), losartan, tissue plasminogen activator, trans-resveratrol, sodium 4-phenyl acetic acid, etc.) in various animal models of steroid-induced OHT were able to match the effectiveness of misoprostol, PF-04217329 or butaprost. Since a common feature of the latter compounds is their relatively high affinity and potency at the EP2-PG receptor sub-type, which activates the production of intracellular cAMP in target cells, our studies suggest that drugs selective for the EP2-PG receptor may be suited to treat corticosteroid-induced OHT.


Assuntos
Acetamidas , Acetatos , Misoprostol , Hipertensão Ocular , Pirazinas , Sulfonamidas , Animais , Camundongos , Misoprostol/farmacologia , Misoprostol/uso terapêutico , Ativador de Plasminogênio Tecidual , Hipertensão Ocular/induzido quimicamente , Hipertensão Ocular/tratamento farmacológico , Receptores de Prostaglandina , Receptores de Prostaglandina E Subtipo EP4 , Esteroides
3.
J Comput Assist Tomogr ; 47(5): 698-703, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37707398

RESUMO

OBJECTIVE: To evaluate the image quality and lesion detectability of pancreatic phase thin-slice computed tomography (CT) images reconstructed with a deep learning-based reconstruction (DLR) algorithm compared with filtered-back projection (FBP) and hybrid iterative reconstruction (IR) algorithms. METHODS: Fifty-three patients who underwent dynamic contrast-enhanced CT including pancreatic phase were enrolled in this retrospective study. Pancreatic phase thin-slice (0.625 mm) images were reconstructed with each FBP, hybrid IR, and DLR. Objective image quality and signal-to-noise ratio of the pancreatic parenchyma, and contrast-to-noise ratio of pancreatic lesions were compared between the 3 reconstruction algorithms. Two radiologists independently assessed the image quality of all images. The diagnostic performance for the detection of pancreatic lesions was compared among the reconstruction algorithms using jackknife alternative free-response receiver operating characteristic analysis. RESULTS: Deep learning-based reconstruction resulted in significantly lower image noise and higher signal-to-noise ratio and contrast-to-noise ratio than hybrid IR and FBP ( P < 0.001). Deep learning-based reconstruction also yielded significantly higher visual scores than hybrid IR and FBP ( P < 0.01). The diagnostic performance of DLR for detecting pancreatic lesions was highest for both readers, although a significant difference was found only between DLR and FBP in one reader ( P = 0.02). CONCLUSIONS: Deep learning-based reconstruction showed improved objective and subjective image quality of pancreatic phase thin-slice CT relative to other reconstruction algorithms and has potential for improving lesion detectability.


Assuntos
Aprendizado Profundo , Neoplasias Pancreáticas , Humanos , Estudos Retrospectivos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Neoplasias Pancreáticas/diagnóstico por imagem
4.
Radiol Med ; 128(6): 629-643, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37120661

RESUMO

OBJECTIVES: To compare the image quality of high-resolution diffusion-weighted imaging (DWI) using multiplexed sensitivity encoding (MUSE) versus reduced field-of-view (rFOV) techniques in endometrial cancer (EC) and to compare the diagnostic performance of these techniques with that of dynamic contrast-enhanced (DCE) MRI for assessing myometrial invasion of EC. METHODS: MUSE-DWI and rFOV-DWI were obtained preoperatively in 58 women with EC. Three radiologists assessed the image quality of MUSE-DWI and rFOV-DWI. For 55 women who underwent DCE-MRI, the same radiologists assessed the superficial and deep myometrial invasion using MUSE-DWI, rFOV-DWI, and DCE-MRI. Qualitative scores were compared using the Wilcoxon signed-rank test. Receiver operating characteristic analysis was performed to compare the diagnostic performance. RESULTS: Artifacts, sharpness, lesion conspicuity, and overall quality were significantly better with MUSE-DWI than with rFOV-DWI (p < 0.05). The area under the curve (AUC) of MUSE-DWI, rFOV-DWI, and DCE-MRI for the assessment of myometrial invasion were not significantly different except for significantly higher AUC of MUSE-DWI than that of DCE-MRI for superficial myometrial invasion (0.76 for MUSE-DWI and 0.64 for DCE-MRI, p = 0.049) and for deep myometrial invasion (0.92 for MUSE-DWI and 0.80 for DCE-MRI, p = 0.022) in one observer, and that of rFOV-DWI for deep myometrial invasion in another observer (0.96 for MUSE-DWI and 0.89 for rFOV-MRI, p = 0.048). CONCLUSION: MUSE-DWI exhibits better image quality than rFOV-DWI. MUSE-DWI and rFOV-DWI shows almost equivalent diagnostic performance compared to DCE-MRI for assessing superficial and deep myometrial invasion in EC although MUSE-DWI may be helpful for some radiologists.


Assuntos
Alprostadil , Neoplasias do Endométrio , Feminino , Humanos , Sensibilidade e Especificidade , Imageamento por Ressonância Magnética/métodos , Imagem de Difusão por Ressonância Magnética/métodos , Neoplasias do Endométrio/diagnóstico por imagem , Neoplasias do Endométrio/patologia
5.
Radiographics ; 42(7): 2095-2111, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36083804

RESUMO

Borderline epithelial ovarian tumors are a distinct pathologic entity characterized by increased epithelial proliferation and nuclear atypia, but without frank stromal invasion. Borderline tumor (BT) is now considered to represent an intermediate phase in the stepwise progression from benign to malignant ovarian epithelial tumor. Since BTs commonly manifest at early stages in women of reproductive age and are associated with a good prognosis, making the correct diagnosis is important in determining whether a patient is a candidate for fertility-sparing surgery. There are six histologic BT subtypes (serous, mucinous, seromucinous, endometrioid, clear cell, and Brenner), and each has different MRI features, reflecting their unique histologic architectures. Radiologists should be aware of the MRI features that can suggest BTs. These features include a hyperintense papillary architecture with hypointense internal branching, which can be observed with serous and seromucinous BTs on T2-weighted images; aggregates of microcysts that have hypointensity on T2-weighted images and reticular enhancement on contrast-enhanced T2-weighted images, which can be seen with mucinous BTs; and moderately high signal intensity on diffusion-weighted images along with relatively high apparent diffusion coefficient values, which can be observed regardless of the histologic subtype. Nevertheless, because the imaging features of BTs overlap with those of many benign lesions (eg, cystadenoma and cystadenofibroma, decidualized endometriosis, and polypoid endometriosis) and malignant tumors (ovarian cancers and metastases), histologic confirmation is required for the final diagnosis. Special emphasis is placed on the MRI features of BTs, pathologic correlation, and the challenges related to diagnosis. ©RSNA, 2022.


Assuntos
Carcinoma , Endometriose , Neoplasias Ovarianas , Feminino , Humanos , Neoplasias Ovarianas/patologia , Imageamento por Ressonância Magnética , Imagem de Difusão por Ressonância Magnética/métodos
6.
Heart Vessels ; 34(10): 1674-1683, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30993441

RESUMO

Transcatheter aortic valve implantation (TAVI) is a viable treatment option for high-risk patients with severe aortic stenosis. In Japan, TAVI can be performed using first-generation self-expandable Medtronic CoreValve or balloon-expandable Edwards SAPIEN-XT from 2012. Since the durability and hemodynamic outcomes after transcatheter heart valve (THV) implantation in Japanese patients have not been clearly elucidated, we assessed serial changes in post-TAVI THV performances over a-3-year period by transthoracic echocardiography (TTE). From January 2012 to September 2014, among 83 patients with severe aortic stenosis, 26 underwent TAVI with CoreValve and 57 underwent TAVI with SAPIEN-XT. We assessed the serial changes in first post-implant (FPI) and 3-year post procedure THV hemodynamics by TTE. Valve performance was evaluated by serial assessment of aortic valve mean pressure gradient (PG) and aortic valve area (AVA) assessments. Three-year clinical outcomes were compared between the patients with CoreValve and those with SAPIEN-XT. Seventeen patients with CoreValve and 34 patients with SAPIEN-XT had FPI and 3-year TTEs. The AVA decreased significantly from FPI to 3-year follow-up among patients with SAPIEN-XT, but not among patients with CoreValve. The mean aortic PG decreased significantly from FPI to the 3-year follow-up point among patients with CoreValve; however, it was not significantly different from those with SAPIEN-XT. The absolute change in mean PG from FPI to the 3-year follow-up point decreased significantly among those with CoreValve compared to those with SAPIEN-XT. Clinical outcomes after TAVI were similar for both devices at 3-years after TAVI. In this study, long-term clinical outcomes for CoreValve and SAPIEN XT were similar. The 3-year THV performance of both devices was maintained after TAVI. Serial change in mean aortic PGs for CoreValve decreases significantly from FPI to the 3-year follow-up point compared to that for SAPIEN-XT.


Assuntos
Estenose da Valva Aórtica/terapia , Valva Aórtica/diagnóstico por imagem , Cateterismo Cardíaco/instrumentação , Hemodinâmica , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Valvuloplastia com Balão/efeitos adversos , Bioprótese , Cateterismo Cardíaco/efeitos adversos , Ecocardiografia , Feminino , Próteses Valvulares Cardíacas , Humanos , Japão , Masculino , Desenho de Prótese , Análise de Sobrevida , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
7.
Mol Pain ; 14: 1744806918767512, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29592786

RESUMO

Background Offset analgesia is a disproportionate decrease of pain perception following a slight decrease of noxious thermal stimulus and attenuated in patients with neuropathic pain. We examined offset analgesia in patients with heterogeneous chronic pain disorders and used functional magnetic resonance imaging to explore modification of cerebral analgesic responses in comparison with healthy controls. Results We recruited seventeen patients with chronic pain and seventeen age-, sex-matched healthy controls. We gave a noxious thermal stimulation paradigm including offset analgesia and control stimuli on the left volar forearm, while we obtained a real-time continuous pain rating and a whole-brain functional magnetic resonance imaging. Baseline, first plateau (5 s), increment (5 s), and second plateau (20 s) temperatures of offset analgesia stimulus were set at 32°C, 46°C, 47°C, and 46°C, respectively. Control stimulus included 30-s 46°C stimulus or only the first 10 s of offset analgesia stimulus. We evaluated magnitude of offset analgesia, analyzed cerebral activation by thermal stimulation, and further compared offset analgesia-related activation between the groups. Magnitude of offset analgesia was larger in controls than in patients (median: 28.9% (interquartile range: 11.0-56.0%) vs. 19.0% (4.2-48.7%), p = 0.047). During the second plateau, controls showed a larger blood oxygenation level-dependent activation than patients at the putamen, anterior cingulate, dorsolateral prefrontal cortices, nucleus accumbens, brainstem, and medial prefrontal cortex ( p < 0.05), which are known to mediate either of descending pain modulation or reward responses. Offset analgesia-related activity at the anterior cingulate cortex was negatively correlated with neuropathic component of pain in patients with chronic pain ( p = 0.004). Conclusions Attenuation of offset analgesia was associated with suppressed activation of the descending pain modulatory and reward systems in patients with chronic pain, at least in the studied cohort. The present findings might implicate both behavioral and cerebral plastic alterations contributing to chronification of pain. Clinical trial registry: The Japanese clinical trials registry (UMIN-CTR, No. UMIN000011253; http://www.umin.ac.jp/ctr /).


Assuntos
Analgesia , Dor Crônica/tratamento farmacológico , Recompensa , Adulto , Idoso , Mapeamento Encefálico , Dor Crônica/psicologia , Demografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Oxigênio/sangue , Temperatura , Fatores de Tempo , Adulto Jovem
8.
Radiology ; 289(1): 255-260, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-29944085

RESUMO

Purpose To examine the diagnostic performance of high-spatial-resolution (HSR) CT with 0.25-mm section thickness for evaluating renal artery in-stent restenosis. Materials and Methods A 0.05-mm wire phantom and vessel phantoms with renal stents with in-stent stenotic sections of varying diameters were scanned with both an HSR CT scanner equipped with 160-section multi-detector rows (0.25-mm section thickness) and a conventional CT scanner. The wire phantom was used to analyze modulation transfer function (MTF). With the vessel phantoms, the error rates were calculated as the absolute difference between the measured diameters and true diameters divided by the true diameters at the narrowing sections. For qualitative evaluation, overall image quality and diagnostic accuracy for evaluating stenosis in three stages were assessed by two radiologists. Statistical analyses included the paired t test, Wilcoxon signed-rank test, and McNemar test. Results HSR CT achieved 24.3 line pairs per centimeter ± 0.5 (standard deviation) and 29.1 line pairs per centimeter ± 0.4 at 10% and 2% MTF, respectively; and conventional CT was 12.5 line pairs per centimeter ± 0.1 and 14.3 line pairs per centimeter ± 0.1 at 10% and 2% MTF, respectively. The mean error rate of the measured diameter at HSR CT (8.0% ± 5.8) was significantly lower than that at at conventional CT (16.9% ± 9.3; P < .001). Image quality at HSR CT was significantly better than that at conventional CT (P < .001), but HSR CT was not significantly superior to conventional CT in terms of diagnostic accuracy. Conclusion Compared with conventional CT, high-spatial-resolution CT achieved spatial resolutions of up to 29 line pairs per centimeter at 2% modulation transfer function and yielded improved measurement accuracy for the evaluation of in-stent restenosis in a phantom study of renal artery stents. Published under a CC BY 4.0 license.


Assuntos
Oclusão de Enxerto Vascular/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Imagens de Fantasmas , Stents , Tomografia Computadorizada por Raios X/métodos , Desenho de Equipamento , Humanos , Modelos Biológicos , Artéria Renal/diagnóstico por imagem , Obstrução da Artéria Renal/diagnóstico por imagem , Tomografia Computadorizada por Raios X/instrumentação
9.
J Comput Assist Tomogr ; 42(3): 412-417, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29189400

RESUMO

OBJECTIVES: The aim of this study was to evaluate the diagnostic ability of magnetic resonance imaging (MRI) in premenopausal women with G1 endometrial carcinoma. METHODS: Twenty-six patients underwent T2W, diffusion weighted, and dynamic contrast-enhanced 3-T MRI. The degree of myometrial invasion was pathologically classified into no invasion, shallow (3 mm or less), and more. Two radiologists assessed myometrial invasion on MRI. Diagnostic accuracy, sensitivity, specificity, positive and negative predictive values, AUC, and interobserver agreement were analyzed. RESULTS: For assessing myometrial invasion, mean accuracy, sensitivity, specificity, positive predictive values, negative predictive values, and AUC, respectively, were as follows: 63%, 42%, 85%, 79%, 47%, and 0.75. Mean interobserver agreement was fair (k = 0.36). Shallow invasions were underestimated as no invasion on MRI in all 6 cases. CONCLUSIONS: Magnetic resonance imaging produced false-negative result on half of patients. The misjudgments tended to happen in patients with shallow invasion.


Assuntos
Neoplasias do Endométrio/diagnóstico por imagem , Preservação da Fertilidade , Imageamento por Ressonância Magnética/métodos , Miométrio/diagnóstico por imagem , Seleção de Pacientes , Pré-Menopausa , Adulto , Neoplasias do Endométrio/patologia , Feminino , Humanos , Pessoa de Meia-Idade , Miométrio/patologia , Invasividade Neoplásica , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
10.
Eur Radiol ; 27(12): 5225-5235, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28674966

RESUMO

OBJECTIVES: To compare the image quality and diagnostic performance of reduced field-of-view (rFOV) versus conventional full field-of-view (fFOV) diffusion-weighted (DW) imaging of endometrial cancer. METHODS: Fifty women with endometrial cancer underwent preoperative rFOV and fFOV DW imaging. Two radiologists compared the image qualities of both techniques, and five radiologists assessed superficial and deep myometrial invasion using both techniques. The statistical analysis included the Wilcoxon signed-rank test and paired t-test for comparisons of image quality and mean diagnostic values. RESULTS: Distortion, tumour delineation, and overall image quality were significantly better with rFOV DW imaging, compared to fFOV DW imaging (P < 0.05); however, the former was inferior in noise (P < 0.05). Regarding superficial invasion, the mean accuracies of the techniques did not differ statistically (rFOV, 58.0% versus fFOV, 56.0%; P = 0.30). Regarding deep myometrial invasion, rFOV DW imaging yielded significantly better mean accuracy, specificity, and positive predictive values (88.4%, 97.8%, and 91.7%, respectively), compared with fFOV DW imaging (84.8%, 94.1%, and 77.4%, respectively; P = 0.009, 0.005, and 0.011, respectively). CONCLUSIONS: Compared with fFOV DW imaging, rFOV DW imaging yielded less distortion, improved image quality and, consequently, better diagnostic performance for deep myometrial invasion of endometrial cancer. KEY POINTS: • rFOV DWI yields better assessment of deep myometrial invasion in endometrial cancer. • rFOV DWI could not sufficiently evaluate superficial invasion in endometrial cancer. • Distortion, tumour delineation, and overall image quality were improved with rFOV DWI.


Assuntos
Adenocarcinoma/patologia , Carcinossarcoma/patologia , Imagem de Difusão por Ressonância Magnética/métodos , Neoplasias do Endométrio/patologia , Endométrio/patologia , Procedimentos Cirúrgicos em Ginecologia , Estadiamento de Neoplasias/métodos , Adenocarcinoma/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinossarcoma/cirurgia , Neoplasias do Endométrio/cirurgia , Estudos de Viabilidade , Feminino , Humanos , Pessoa de Meia-Idade , Miométrio/patologia , Invasividade Neoplásica/patologia , Período Pré-Operatório , Curva ROC
11.
J Anesth ; 30(6): 1051-1055, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27514383

RESUMO

Transcatheter aortic valve implantation (TAVI) for patients with aortic stenosis is a less invasive alternative to surgical aortic valve replacement. Despite this, careful anesthetic management, especially strict control of blood pressure and fluid management, is necessary. During TAVI, normalization of left ventricular afterload due to aortic balloon valvuloplasty and prosthetic valve deployment is expected to result in rapid improvement of systolic function and consequent improvement in diastolic function. However, the early effect of TAVI on left ventricular diastolic function is less clear. We hypothesized that TAVI induces a rapid decrease in left ventricular end-diastolic pressure (LVEDP) after valve deployment. This retrospective observational study included 71 patients who had undergone TAVI using the transfemoral approach with a balloon-expandable valve under general anesthesia. Intraoperative LVEDP was measured using an intracardiac catheter. The severity of residual aortic regurgitation (AR) was assessed using the Sellers criteria. The mean (SD) LVEDP was 17.8 (5.3) mmHg just before TAVI and increased significantly to 27.3 (8.2) mmHg immediately after prosthetic valve deployment (p < 0.0001). The change in LVEDP was 8.7 (8.6) mmHg in patients with low residual AR (Sellers ≤1) and 11.0 (7.1) mmHg in those with high residual AR (Sellers ≥2); however, this difference was not significant. No correlation was found between the LVEDP change and intraoperative fluid balance. In conclusion, LVEDP increased significantly in the early period after valve deployment during TAVI, regardless of residual AR severity. It was suggested that the tolerability of fluid load could be reduced at that time.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/métodos , Função Ventricular Esquerda , Idoso , Idoso de 80 Anos ou mais , Insuficiência da Valva Aórtica/patologia , Pressão Sanguínea , Feminino , Humanos , Masculino , Estudos Retrospectivos , Índice de Gravidade de Doença
12.
Micromachines (Basel) ; 15(2)2024 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-38398942

RESUMO

Stent retrievers are medical devices that are designed to physically remove blood clots from within the blood vessels of the brain. This paper focuses on microfabricated nitinol (nickel-titanium alloy) stent retrievers, which feature micro-patterns on their surface to enhance the effectiveness of mechanical thrombectomy. A thick film of nitinol, which was 20 µm in thickness, was sputtered onto a substrate with a micro-patterned surface, using electroplated copper as the sacrificial layer. The nitinol film was released from the substrate and then thermally treated while folded into a cylindrical shape. In vitro experiments with pig blood clots demonstrated that the micro-patterns on the surface improved the efficacy of blood clot retrieval.

13.
Pharmaceuticals (Basel) ; 17(6)2024 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-38931465

RESUMO

The effects of brain-derived neurotrophic factor (BDNF) on retinal ganglion cell (RGC) survival and visual function were assessed in rat and mouse models of optic nerve (ON) crush. ONs were crushed on Day 1, followed by intravitreal injections of a vehicle or BDNF on Days 1 and 8. The spatial frequency threshold was measured using optokinetic tracking on Days 7 and 14. On Day 15, ganglion cell complex (GCC) thickness was quantified using optical coherence tomography. Furthermore, all eyes were enucleated for immunohistochemical analysis of the surviving RGC somas and axons. BDNF significantly reduced the RGC soma in mice and increased GCC thickness in intact eyes, with apparent axonal swelling in both species. It displayed significantly greater RGC soma survival in eyes with ON injury, with moderately thicker axonal bundles in both species and a thicker GCC in rats. Visual function was significantly reduced in all ON-crushed animals, regardless of BDNF treatment. Thus, we obtained a comprehensive analysis of the structural and functional impact of BDNF in intact and ON-crushed eyes in two rodent models. Our results provide a foundation for further BDNF evaluation and the design of preclinical studies on neuroprotectants using BDNF as a reference positive control.

14.
Jpn J Radiol ; 42(6): 599-611, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38351253

RESUMO

PURPOSE: Liver and pancreatic fibrosis is associated with diabetes mellitus (DM), and liver fibrosis is associated with pancreatic fibrosis. This study aimed to investigate the relationship between the hepatic and pancreatic extracellular volume fractions (fECVs), which correlate with tissue fibrosis, and their relationships with DM and pre-DM (pDM). MATERIAL AND METHODS: We included 100 consecutive patients with known or suspected liver and/or pancreatic diseases who underwent contrast-enhanced CT. Patients were classified as nondiabetes, pDM, and DM with hemoglobin A1c (HbA1c) levels of < 5.7%, 5.7%-6.5%, and ≥ 6.5% or fasting plasma glucose (FPG) levels of < 100, 100-125 mg/dL, and ≥ 126 mg/dL, respectively. Subtraction images between unenhanced and equilibrium-phase images were prepared. The liver and the pancreas were automatically extracted using a high-speed, three-dimensional image analysis system, and their respective mean CT values were calculated. The enhancement degree of the aorta (Δaorta) was measured. fECV was calculated using the following equation: fECV = (100 - hematocrit) * Δliver or pancreas/Δaorta. Differences were investigated in hepatic and pancreatic fECVs among the three groups, and the correlation between each two in hepatic fECV, pancreatic fECV, and HbA1c was determined. RESULTS: The pancreatic fECV, which was positively correlated with the hepatic fECV and HbA1c (r = 0.51, P < 0.001, and r = 0.51, P < 0.001, respectively), significantly differed among the three groups (P < 0.001) and was significantly greater in DM than in pDM or nondiabetes and in pDM with nondiabetes (P < 0.001). Hepatic fECV was significantly greater in DM than in nondiabetes (P < 0.05). CONCLUSION: The pancreatic fECV and pDM/DM are closely related.


Assuntos
Meios de Contraste , Fígado , Estado Pré-Diabético , Tomografia Computadorizada por Raios X , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X/métodos , Idoso , Fígado/diagnóstico por imagem , Estado Pré-Diabético/diagnóstico por imagem , Pâncreas/diagnóstico por imagem , Pâncreas/patologia , Adulto , Diabetes Mellitus/diagnóstico por imagem , Idoso de 80 Anos ou mais , Imageamento Tridimensional/métodos , Cirrose Hepática/diagnóstico por imagem , Estudos Retrospectivos
15.
Magn Reson Med Sci ; 23(2): 214-224, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-36990740

RESUMO

PURPOSE: To compare the effects of deep learning reconstruction (DLR) on respiratory-triggered T2-weighted MRI of the liver between single-shot fast spin-echo (SSFSE) and fast spin-echo (FSE) sequences. METHODS: Respiratory-triggered fat-suppressed liver T2-weighted MRI was obtained with the FSE and SSFSE sequences at the same spatial resolution in 55 patients. Conventional reconstruction (CR) and DLR were applied to each sequence, and the SNR and liver-to-lesion contrast were measured on FSE-CR, FSE-DLR, SSFSE-CR, and SSFSE-DLR images. Image quality was independently assessed by three radiologists. The results of the qualitative and quantitative analyses were compared among the four types of images using repeated-measures analysis of variance or Friedman's test for normally and non-normally distributed data, respectively, and a visual grading characteristics (VGC) analysis was performed to evaluate the image quality improvement by DLR on the FSE and SSFSE sequences. RESULTS: The liver SNR was lowest on SSFSE-CR and highest on FSE-DLR and SSFSE-DLR (P < 0.01). The liver-to-lesion contrast did not differ significantly among the four types of images. Qualitatively, noise scores were worst on SSFSE-CR but best on SSFSE-DLR because DLR significantly reduced noise (P < 0.01). In contrast, artifact scores were worst both on FSE-CR and FSE-DLR (P < 0.01) because DLR did not reduce the artifacts. Lesion conspicuity was significantly improved by DLR compared with CR in the SSFSE (P < 0.01) but not in FSE sequences for all readers. Overall image quality was significantly improved by DLR compared with CR for all readers in the SSFSE (P < 0.01) but only one reader in the FSE (P < 0.01). The mean area under the VGC curve values for the FSE-DLR and SSFSE-DLR sequences were 0.65 and 0.94, respectively. CONCLUSION: In liver T2-weighted MRI, DLR produced more marked improvements in image quality in SSFSE than in FSE.


Assuntos
Aprendizado Profundo , Neoplasias Hepáticas , Humanos , Imageamento por Ressonância Magnética/métodos , Neoplasias Hepáticas/patologia , Artefatos
16.
Abdom Radiol (NY) ; 2024 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-38888738

RESUMO

Photon-counting CT has a completely different detector mechanism than conventional energy-integrating CT. In the photon-counting detector, X-rays are directly converted into electrons and received as electrical signals. Photon-counting CT provides virtual monochromatic images with a high contrast-to-noise ratio for abdominal CT imaging and may improve the ability to visualize small or low-contrast lesions. In addition, photon-counting CT may offer the possibility of reducing radiation dose. This review provides an overview of the actual clinical operation of photon-counting CT and its diagnostic utility in abdominal imaging. We also describe the clinical implications of photon-counting CT including imaging of hepatocellular carcinoma, liver metastases, hepatic steatosis, pancreatic cancer, intraductal mucinous neoplasm of the pancreas, and thrombus.

17.
J Med Ultrason (2001) ; 50(3): 441-446, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37209165

RESUMO

PURPOSE: This study sought to clarify the positional relationship between the Achilles tendon and sural nerve using ultrasound. METHODS: We studied 176 legs in 88 healthy volunteers. The positional relationship between the Achilles tendon and sural nerve at heights of 2, 4, 6, 8, 10, and 12 cm proximal from the calcaneus' proximal margin was investigated by distance and depth. Setting the X-axis (left/right) as the horizontal axis and Y-axis (depth) as the vertical axis against ultrasound images, we investigated the distance between the lateral margin of the Achilles tendon to the midpoint of the sural nerve on the X-axis. The Y-axis was split into four zones: the part behind the center of the Achilles tendon (AS), the part in front of the center of the Achilles tendon (AD), the part behind the Achilles tendon (S), and the part in front (D). We investigated the zones through which the sural nerve passed. We also studied any significant differences between the sexes and left/right legs. RESULTS: The mean distance on the X-axis was closest at 6 cm, with 1.1 ± 5.0 mm between them. The sural nerve's position on the Y-axis was such that at positions more proximal than 8 cm, the sural nerve ran through zone S in most legs and moved to zone AS through heights 2-6 cm. No parameters showed significant differences between the sexes or left/right legs. CONCLUSION: We presented the positional relationship between the Achilles tendon and sural nerve and suggested some measures to prevent nerve injury during surgery.


Assuntos
Tendão do Calcâneo , Humanos , Tendão do Calcâneo/diagnóstico por imagem , Nervo Sural/diagnóstico por imagem , Nervo Sural/lesões , Perna (Membro) , Ultrassonografia/métodos , Voluntários Saudáveis
18.
Magn Reson Med Sci ; 2023 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-37899224

RESUMO

PURPOSE: To compare objective and subjective image quality, lesion conspicuity, and apparent diffusion coefficient (ADC) of high-resolution multiplexed sensitivity-encoding diffusion-weighted imaging (MUSE-DWI) with conventional DWI (c-DWI) and reduced FOV DWI (rFOV-DWI) in prostate MRI. METHODS: Forty-seven patients who underwent prostate MRI, including c-DWI, rFOV-DWI, and MUSE-DWI, were retrospectively evaluated. SNR and ADC of normal prostate tissue and contrast-to-noise ratio (CNR) and ADC of prostate cancer (PCa) were measured and compared between the three sequences. Image quality and lesion conspicuity were independently graded by two radiologists using a 5-point scale and compared between the three sequences. RESULTS: The SNR of normal prostate tissue was significantly higher with rFOV-DWI than with the other two DWI techniques (P ≤ 0.01). The CNR of the PCa was significantly higher with rFOV-DWI than with MUSE-DWI (P < 0.05). The ADC of normal prostate tissue measured by rFOV-DWI was lower than that measured by MUSE-DWI and c-DWI (P < 0.01), while there was no difference in the ADC of cancers. In the qualitative analysis, MUSE-DWI showed significantly higher scores than rFOV-DWI and c-DWI for visibility of anatomy and overall image quality in both readers, and significantly higher scores for distortion in one of the two readers (P < 0.001). There was no difference in lesion conspicuity between the three sequences. CONCLUSION: High-resolution MUSE-DWI showed higher image quality and reduced distortion compared to c-DWI, while maintaining a wide FOV and similar ADC quantification, although no difference in lesion conspicuity was observed.

19.
Invest Radiol ; 2023 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-37975732

RESUMO

OBJECTIVE: The aim of this study was to evaluate the impact of ultra-high-resolution acquisition and deep learning reconstruction (DLR) on the image quality and diagnostic performance of T2-weighted periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) imaging of the rectum. MATERIALS AND METHODS: This prospective study included 34 patients who underwent magnetic resonance imaging (MRI) for initial staging or restaging of rectal tumors. The following 4 types of oblique axial PROPELLER images perpendicular to the tumor were obtained: a standard 3-mm slice thickness with conventional reconstruction (3-CR) and DLR (3-DLR), and 1.2-mm slice thickness with CR (1.2-CR) and DLR (1.2-DLR). Three radiologists independently evaluated the image quality and tumor extent by using a 5-point scoring system. Diagnostic accuracy was evaluated in 22 patients with rectal cancer who underwent surgery after MRI without additional neoadjuvant therapy (median interval between MRI and surgery, 22 days). The signal-to-noise ratio and tissue contrast were measured on the 4 types of PROPELLER imaging. RESULTS: 1.2-DLR imaging showed the best sharpness, overall image quality, and rectal and lesion conspicuity for all readers (P < 0.01). Of the assigned scores for tumor extent, extramural venous invasion (EMVI) scores showed moderate agreement across the 4 types of PROPELLER sequences in all readers (intraclass correlation coefficient, 0.60-0.71). Compared with 3-CR imaging, the number of cases with MRI-detected extramural tumor spread was significantly higher with 1.2-DLR imaging (19.0 ± 2.9 vs 23.3 ± 0.9, P = 0.03), and the number of cases with MRI-detected EMVI was significantly increased with 1.2-CR, 3-DLR, and 1.2-DLR imaging (8.0 ± 0.0 vs 9.7 ± 0.5, 11.0 ± 2.2, and 12.3 ± 1.7, respectively; P = 0.02). For the diagnosis of histopathologic extramural tumor spread, 3-CR and 1.2-CR had significantly higher specificity than 3-DLR and 1.2-DLR imaging (0.75 and 0.78 vs 0.64 and 0.58, respectively; P = 0.02), and only 1.2-CR had significantly higher accuracy than 3-CR imaging (0.83 vs 0.79, P = 0.01). The accuracy of MRI-detected EMVI with reference to pathological EMVI was significantly lower for 3-CR and 3-DLR compared with 1.2-CR (0.77 and 0.74 vs 0.85, respectively; P < 0.01), and was not significantly different between 1.2-CR and 1.2-DLR (0.85 vs 0.80). Using any pathological venous invasion as the reference standard, the accuracy of MRI-detected EMVI was significantly the highest with 1.2-DLR, followed by 1.2-CR, 3-CR, and 3-DLR (0.71 vs 0.67 vs 0.59 vs 0.56, respectively; P < 0.01). The signal-to-noise ratio was significantly highest with 3-DLR imaging (P < 0.05). There were no significant differences in tumor-to-muscle contrast between the 4 types of PROPELLER imaging. CONCLUSIONS: Ultra-high-resolution PROPELLER T2-weighted imaging of the rectum combined with DLR improved image quality, increased the number of cases with MRI-detected extramural tumor spread and EMVI, but did not improve diagnostic accuracy with respect to pathology in rectal cancer, possibly because of false-positive MRI findings or false-negative pathologic findings.

20.
Eur J Radiol ; 150: 110271, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35334243

RESUMO

PURPOSE: A newly developed Adaptive Image Receive (AIR) coil is designed to be more flexible to conform to the human body habitus, and may improve image quality by reducing the distance between the coil element and the imaging subject. This study evaluated the AIR coil's usefulness for liver MR imaging at 3.0 T in comparison with that of a conventional coil retrospectively. METHOD: The study population comprised 50 consecutive patients, who underwent follow-up liver MR examinations with a 3.0-T MR system using both an AIR coil and a conventional coil to evaluate hepatocellular carcinoma. Three-dimensional fat-suppressed T1-weighted gradient-echo images before and after injection of an MRI contrast agent, T2-weighted single-shot fast spin-echo (SSFSE) images, and diffusion-weighted (DW) images obtained with the AIR coil were compared with corresponding images obtained with the conventional coil. One radiologist measured signal-to-noise ratios (SNRs), while two other radiologists used a 3-point scale to independently assess subjective image noise, artifacts, signal uniformity, and overall image quality. RESULTS: SNRs for the AIR coil were significantly higher than those for the conventional coil (P <.05). Subjective image noise for the AIR coil on pre- and postcontrast T1-weighted and DW images was lower than for the conventional coil for both readers (P <.05). Overall image quality on pre- and postcontrast T1-weighted and DW images for the AIR coil was better than that for the conventional coil for at least one reader (P <.05). CONCLUSIONS: In comparison with the conventional coil, AIR coil improved SNR and image quality of liver MR imaging.


Assuntos
Neoplasias Hepáticas , Imageamento por Ressonância Magnética , Humanos , Aumento da Imagem/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Estudos Retrospectivos , Tecnologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA