Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 51
Filtrar
1.
Macromol Rapid Commun ; 39(6): e1700727, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29356234

RESUMO

Thermoelectric materials can be used as the active materials in thermoelectric generators and as Peltier coolers for direct energy conversion between heat and electricity. Apart from inorganic thermoelectric materials, thermoelectric polymers have been receiving great attention due to their unique advantages including low cost, high mechanical flexibility, light weight, low or no toxicity, and intrinsically low thermal conductivity. The power factor of thermoelectric polymers has been continuously rising, and the highest ZT value is more than 0.25 at room temperature. The power factor can be further improved by forming composites with nanomaterials. This article provides a review of recent developments on thermoelectric polymers and polymer composites. It focuses on the relationship between thermoelectric properties and the materials structure, including chemical structure, microstructure, dopants, and doping levels. Their thermoelectric properties can be further improved to be comparable to inorganic counterparts in the near future.


Assuntos
Polímeros/química , Nanoestruturas/química , Condutividade Térmica
2.
Angew Chem Int Ed Engl ; 56(50): 16073-16076, 2017 12 11.
Artigo em Inglês | MEDLINE | ID: mdl-29071807

RESUMO

It is very important to study the crystallization of hybrid organic-inorganic perovskites because their thin films are usually prepared from solution. The investigation on the growth of perovskite films is however limited by their polycrystallinity. In this work, methylammonium lead triiodide single crystals grown from solutions with different methylammonium iodide (MAI):lead iodide (PbI2 ) ratios were investigated. We observed a V-shaped dependence of the crystallization onset temperature on the MAI:PbI2 ratio. This is attributed to the MAI effects on the supersaturation of precursors and the interfacial energy of the crystal growth. At low MAI:PbI2 ratio (<1.7), more MAI leads to the supersaturation of the precursors at lower temperature. At high MAI:PbI2 ratio, the crystal growing plans change from (100)-plane dominated to (001)-plane dominated. The latter have higher interfacial energy than the former, leading to a higher crystallization onset temperature.

3.
Chem Asian J ; : e202400329, 2024 May 12.
Artigo em Inglês | MEDLINE | ID: mdl-38736306

RESUMO

It is of great significance to develop high-performance thermoelectric (TE) materials, because they can be used to harvest waste heat into electricity and there is abundant waste heat on earth. The conventional TE materials are inorganic semimetals or semiconductors like Bi2Te3 and its derivatives. However, they have problems of high cost, scare/toxic elements, high thermal conductivity, and poor mechanical flexibility. Organic TE materials emerged as the next-generation TE materials because of their merits including solution processability, low cost, abundant element, low intrinsic thermal conductivity, and high mechanical flexibility. Organic TE materials are mainly conducting polymers because of their high conductivity. Both the conductivity and Seebeck coefficient depend on the doping level, and they are interdependent. Hence, the TE properties of polymers can be improved through doping/dedoping engineering. There are three types of doping forms, oxidative (or reductive) doping, protonic acid doping, and charge transfer doping. Accordingly, they can be dedoped by different approaches. In this article, we review the methods to dope and dedope p-type and n-type TE polymers and the combination of doping and dedoping to optimize their TE properties. Secondary doping is also covered, since it can significantly enhance the conductivity of some TE polymers.

4.
ACS Appl Mater Interfaces ; 16(25): 32578-32586, 2024 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-38865685

RESUMO

Monitoring the gastric digestive function is important for the diagnosis of gastric disorders and drug development. However, there is no report on the in situ and real-time monitoring of digestive functions. Herein, we report a flexible fully organic sensor to effectively monitor protein digestion in situ in a simulated gastric environment for the first time. The sensors are made of a blend of gluten that is a protein and poly(3,4-ethylenedioxythiophene):polystyrenesulfonate (PEDOT:PSS) that is a conducting polymer. During the protein digestion, the breakdown of the polypeptides increases the level of separation among the PEDOT chains, thereby increasing the resistance. The resistance variation is sensitive to various conditions, including the concentration of pepsin that is the enzyme for protein digestion, temperature, pH value, and digestive drugs. Hence, these sensors can provide real-time information about the digestion and efficacy of digestive drugs. In addition, the signals can be collected via a convenient wireless communication manner.


Assuntos
Poliestirenos , Humanos , Poliestirenos/química , Digestão , Polímeros/química , Pepsina A/metabolismo , Pepsina A/química , Concentração de Íons de Hidrogênio , Temperatura , Tiofenos
5.
J Colloid Interface Sci ; 630(Pt A): 23-33, 2023 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-36215821

RESUMO

Adhesion between flexible devices and skin surface facilitates portability of devices and reliable signal acquisition from human body, which is essential for medical therapy devices or monitoring systems. Here, we utilize a simple, cost-effective, and scalable layer-by-layer dip-coating method to fabricate a skin-adhesive multifunctional textile-based device, consisting of three parts: low-cost and easily available airlaid paper (AP) substrate, conductive MXene sensitive layer, and adhesive polydimethylsiloxane (PDMS). The adhesive layer of lightly cross-linked PDMS enables the device to form conformal contact with skin even during human joint bending. The smart textile device exhibits excellent electro-thermal and photo-thermal conversion performance with good cycling stability and tunability. Furthermore, the textile electronics show good electromagnetic interference (EMI) shielding properties due to the good electrical conductivity, as well as sensitive and stable pressure sensing properties for human motion detection. Consequently, this efficient strategy provides a possible way to design multifunctional and wearable electronic textiles for medical applications.


Assuntos
Dispositivos Eletrônicos Vestíveis , Humanos , Adesivos , Calefação , Têxteis , Eletrônica , Condutividade Elétrica
6.
Phys Chem Chem Phys ; 14(45): 15793-801, 2012 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-23086437

RESUMO

Deposition of nanostructured metals on substrates is important for the fundamental study and practical application, such as in optics and catalysis. In this paper, we report the deposition of gold (Au) nanoplates and porous platinum (Pt) structures on substrates through solvent-free chemical reductions of chloroauric acid (HAuCl(4)) and chloroplatinic acid (H(2)PtCl(6)) with ethylene glycol (EG) vapor at temperatures below 200 °C. The process includes two steps. The first step is the formation of a thin layer of a metal precursor on substrates by coating solution of a metal precursor. The thin metal precursor layer is subsequently dried by annealing. The second step is the chemical reduction of the metal precursor with EG vapor at 160 or 180 °C in the absence of solvent. Both the Au and Pt nanostructures deposited by this method have good adhesion to substrates, but they have different morphologies. The Au nanostructures appear as separate two-dimensional islands on the substrates, and up to 70% of them can be triangular nanoplates with the (111) crystal plane as the basal plane. In contrast, the reduction of H(2)PtCl(6) gives rise to a 3-dimensional porous Pt structure on substrates. The different morphologies of nanostructured Au and Pt are tentatively related to the different surface energies of Au and Pt.


Assuntos
Cloretos/química , Etilenoglicol/química , Compostos de Ouro/química , Ouro/química , Nanopartículas Metálicas/química , Compostos de Platina/química , Platina/química , Oxirredução , Tamanho da Partícula , Porosidade , Propriedades de Superfície , Volatilização
7.
J Phys Chem Lett ; 13(46): 10830-10842, 2022 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-36382894

RESUMO

Cations and anions can accumulate at the two ends of an ionic conductor under temperature gradient, which is the so-called Soret effect. This can generate a voltage between the two electrodes, and the thermopower can be higher than that of the electronic conductors because of the Seebeck effect by 1-2 orders in magnitude. The thermoelectric properties of ionic conductors depend on the ionic thermopower, ionic conductivity, and thermal conductivity. Compared with other ionic conductors, like liquid electrolytes and hydrogels, ionogels made of an ionic liquid and a gelator can have the advantages of high thermopower and high stability. Great progress was recently made to improve the ionic conductivity and/or ionic thermopower of ionogels. They can be used in ionic thermoelectric capacitors (ITECs) to harvest heat. In addition, they can be integrated with electronic thermoelectric materials to harvest heat from both temperature gradient and temperature fluctuation, which can be caused by waste heat.

8.
Soft Robot ; 9(4): 705-712, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-34388046

RESUMO

Tunable lens technology inspired by the human eye has opened a new paradigm of smart optical devices for a variety of applications due to unique characteristics such as lightweight, low cost, and facile fabrication over conventional lens assemblies. The fast-growing demands for tunable optical lenses in consumer electronics, medical diagnostics, and optical communications require the lens to have a large focal length modulation range and high compactness. Herein, for the first time, an all-solid tunable soft lens driven by highly transparent dielectric elastomer actuators (DEAs) based on poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) and waterborne polyurethane (PEDOT:PSS/WPU) transparent electrodes is developed. The deformation of the tunable soft lens is achieved by the actuation of DEAs, mimicking the change of the surface profile of the human eye to achieve remarkable focal length variations. Upon electrical activation, this tunable soft lens can vary its original focal length by 209%, which is one of the highest among current tunable soft lenses and far beyond that of the human eye. This study demonstrates that transparent DEAs are capable of achieving focus-variation functions, and potentially useful in artificial robotic vision, visual prostheses, and adjustable glasses, which will induce significant effects on the future development of tunable optics.


Assuntos
Cristalino , Lentes , Dispositivos Ópticos , Robótica , Elastômeros , Humanos , Cristalino/fisiologia
9.
Nanomicro Lett ; 14(1): 117, 2022 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-35488940

RESUMO

Flexible perovskite solar cells (FPSCs) have attracted enormous interest in wearable and portable electronics due to their high power-per-weight and low cost. Flexible and efficient perovskite solar cells require the development of flexible electrodes compatible with the optoelectronic properties of perovskite. In this review, the recent progress of flexible electrodes used in FPSCs is comprehensively reviewed. The major features of flexible transparent electrodes, including transparent conductive oxides, conductive polymer, carbon nanomaterials and nanostructured metallic materials are systematically compared. And the corresponding modification strategies and device performance are summarized. Moreover, flexible opaque electrodes including metal films, opaque carbon materials and metal foils are critically assessed. Finally, the development directions and difficulties of flexible electrodes are given.

10.
Sci Adv ; 8(47): eabq8160, 2022 Nov 25.
Artigo em Inglês | MEDLINE | ID: mdl-36427298

RESUMO

High mechanical ductility and high mechanical strength are important for materials including polymers. Current methods to increase the ductility of polymers such as plasticization always cause a remarkable drop in the ultimate tensile strength. There is no report on the ductilization of polymers that can notably increase the elongation at break while not lowering the ultimate tensile strength. Here, we report the salt-induced ductilization of an intrinsically conducting polymer, poly(3,4-ethylenedioxythiophene):polystyrenesulfonate (PEDOT:PSS). Treating highly conductive PEDOT:PSS with a salt such as sodium perchlorate can enhance its elongation at break from 8.5 to 53.2%, whereas it hardly affects the tensile strength. Moreover, the resistance of the ductilized PEDOT:PSS films is insensitive to the tensile strain before fracture and slightly increases by only ~6% during the cyclic tensile testing with the strain up to 30%. These effects are ascribed to the decrease in the Coulomb attraction between PEDOT+ and PSS- by the salt ions.

11.
ACS Appl Mater Interfaces ; 14(34): 39159-39171, 2022 Aug 31.
Artigo em Inglês | MEDLINE | ID: mdl-35973944

RESUMO

Dry epidermal electrodes that can always form conformal contact with skin can be used for continuous long-term biopotential monitoring, which can provide vital information for disease diagnosis and rehabilitation. But, this application has been limited by the poor contact of dry electrodes on wet skin. Herein, we report a biocompatible fully organic dry electrode that can form conformal contact with both dry and wet skin even during physical movement. The dry electrodes are prepared by drop casting an aqueous solution consisting of poly(3,4-ethylenedioxythiophene):polystyrenesulfonate (PEDOT:PSS), poly(vinyl alcohol) (PVA), tannic acid (TA), and ethylene glycol (EG). The electrodes can exhibit a conductivity of 122 S cm-1 and a mechanical stretchability of 54%. Moreover, they are self-adhesive to not only dry skin but also wet skin. As a result, they can exhibit a lower contact impedance to skin than commercial Ag/AgCl gel electrodes on both dry and sweat skins. They can be used as dry epidermal electrodes to accurately detect biopotential signals including electrocardiogram (ECG) and electromyogram (EMG) on both dry and wet skins for the users at rest or during physical movement. This is the first time to demonstrate dry epidermal electrodes self-adhesive to wet skin for accurate biopotential detection.


Assuntos
Cimentos de Resina , Suor , Adesivos , Compostos Bicíclicos Heterocíclicos com Pontes , Eletrodos , Desenho de Equipamento , Polímeros
12.
J Phys Chem Lett ; 13(20): 4621-4627, 2022 May 26.
Artigo em Inglês | MEDLINE | ID: mdl-35587455

RESUMO

Ionic thermoelectric (i-TE) material with mobile ions as charge carriers has the potential to generate large thermal voltages at low operating temperatures. This study highlights the role of ions in i-TE hydrogels employing a poly(vinyl alcohol) (PVA) polymer matrix and a number of ion providers, e.g., KOH, KNO3, KCl, KBr, NaI, KI, and CsI. The relationship between the intrinsic physical parameters of the ion and the thermoelectric performance is established, indicating the ability to influence the hydrogen bond by the ion is a crucial factor. Among these i-TE hydrogels, the PVA/CsI hydrogel exhibits the largest ionic Seebeck coefficient, reaching 52.9 mV K-1, which is the largest of all i-TE materials reported to date. In addition, our work demonstrates the influence of ions on polymer configuration and provides an avenue for ion selection in the Soret effect in ionic thermoelectrics.

13.
Langmuir ; 27(17): 10953-61, 2011 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-21800893

RESUMO

Electronically and ionically conductive gels were fabricated by mixing and mechanically grinding neutral tetrathiafulvalene (TTF) and tetracyanoquinodimethane (TCNQ) in ionic liquids (ILs) like 3-ethyl-1-methylimidazolium dicyanoamide (EMIDCA), 1-ethyl-3-methylimidazolium thiocyanate (EMISCN), 1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide (EMITf(2)N), trihexyltetradecylphosphonium bis(trifluoromethylsulfonyl)imide (P(14,6,6,6)Tf(2)N), and methyl-trioctylammonium bis(trifluoromethylsulfonyl)imide (MOATf(2)N). Charge-transfer TTF-TCNQ crystallites were generated during the mechanical grinding as indicated by the UV-visibile-near-infrared (UV-vis-NIR) absorption spectroscopy, Fourier transform infrared (FTIR) spectroscopy, and X-ray diffraction. The charge-transfer TTF-TCNQ crystallites have a needle-like shape. They form solid networks to gelate the ILs. The gel behavior is confirmed by the dynamic mechanical measurements. It depends on both the anions and cations of the ILs. In addition, when 1-methyl-3-butylimidazolium tetrafluoroborate (BMIBF(4)) and 1-methyl-3-propylimidazolium iodide (PMII) were used, the TTF-TCNQ/IL mixtures did not behave as gels. The TTF-TCNQ/IL gels are both electronically and ionically conductive, because the solid phase formed by the charge-transfer TTF-TCNQ crystallites is electronically conductive, while the ILs are ionically conductive. The gel formation is related to needle-like charge-transfer TTF-TCNQ cyrstallites and the π-π and Coulombic interactions between TTF-TCNQ and ILs.


Assuntos
Géis/química , Compostos Heterocíclicos/química , Líquidos Iônicos/química , Nitrilas/química , Condutividade Elétrica , Íons/química , Estrutura Molecular , Tamanho da Partícula , Propriedades de Superfície
14.
ACS Appl Mater Interfaces ; 13(17): 20735-20745, 2021 May 05.
Artigo em Inglês | MEDLINE | ID: mdl-33900075

RESUMO

Conductive stretchable hydrogels and ionogels consisting of ionic liquids can have interesting application as wearable strain and pressure sensors and bioelectrodes due to their soft nature and high conductivity. However, hydrogels have a severe stability problem because of water evaporation, whereas ionogels are not biocompatible or even toxic. Here, we demonstrate self-adhesive, stretchable, nonvolatile, and biocompatible eutectogels that can always form conformal contact to skin even during body movement along with their application as wearable strain and pressure sensors and biopotential electrodes for precise health monitoring. The eutectogels consist of a deep eutectic solvent that has high conductivity, waterborne polyurethane that is an elastomer, and tannic acid that is an adhesive. They can have an elongation at a break of 178%, ionic conductivity of 0.22 mS/cm, and adhesion force of 12.5 N/m to skin. They can be used as conformal strain sensors to accurately monitor joint movement and breath. They can be even used as pressure sensors with a piezoresistive sensitivity of 284.4 kPa-1 to precisely detect subtle physical movements like arterial pulses, which can provide vital cardiovascular information. Moreover, the eutectogels can be used as nonvolatile conformal electrodes to monitor epidermal physiological signals, such as electrocardiogram (ECG) and electromyogram (EMG).


Assuntos
Adesivos , Materiais Biocompatíveis , Eletrodos , Géis , Dispositivos Eletrônicos Vestíveis , Eletrocardiografia , Eletromiografia , Humanos , Pressão
15.
ACS Appl Mater Interfaces ; 13(31): 37816-37829, 2021 Aug 11.
Artigo em Inglês | MEDLINE | ID: mdl-34323464

RESUMO

Safer human-robot interactions mandate the adoption of proprioceptive actuation. Strain sensors can detect the deformation of tools and devices in unstructured and capricious environments. However, such sensor integration in surgical/clinical settings is challenging due to confined spaces, structural complexity, and performance losses of tools and devices. Herein, we report a highly stretchable skin-like strain sensor based on a silver nanowire (AgNW) layer and hydrogel substrate. Our facile fabrication method utilizes thermal annealing to modulate the gauge factor (GF) by forming multidimensional wrinkles and a layered conductive network. The developed AgNW-hydrogel (AGel) sensors sustain and exhibit a strain-sensitive profile (max. GF = ∼70) with high stretchability (200%). Due to its conformability, the sensor demonstrates efficacy in integration and motion monitoring with minimal mechanical constraints. We provide contextual cognizance of tooltip during a transoral procedure by incorporating AGel sensors and showing the fabrication methodology's versatility by developing a hybrid self-sensing actuator with real-time performance feedback.

16.
Nat Biomed Eng ; 5(10): 1217-1227, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34654900

RESUMO

Monitoring surgical wounds post-operatively is necessary to prevent infection, dehiscence and other complications. However, the monitoring of deep surgical sites is typically limited to indirect observations or to costly radiological investigations that often fail to detect complications before they become severe. Bioelectronic sensors could provide accurate and continuous monitoring from within the body, but the form factors of existing devices are not amenable to integration with sensitive wound tissues and to wireless data transmission. Here we show that multifilament surgical sutures functionalized with a conductive polymer and incorporating pledgets with capacitive sensors operated via radiofrequency identification can be used to monitor physicochemical states of deep surgical sites. We show in live pigs that the sutures can monitor wound integrity, gastric leakage and tissue micromotions, and in rodents that the healing outcomes are equivalent to those of medical-grade sutures. Battery-free wirelessly operated bioelectronic sutures may facilitate post-surgical monitoring in a wide range of interventions.


Assuntos
Deiscência da Ferida Operatória , Ferida Cirúrgica , Animais , Técnicas de Sutura , Suturas , Suínos , Cicatrização
17.
Nanotechnology ; 21(39): 395202, 2010 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-20820098

RESUMO

High-performance dye-sensitized solar cells (DSCs) with binder-free films of carbon nanotubes (CNTs), including single-walled CNTs (SWCNTs) and multi-walled CNTs (MWCNTs), as the counter electrode are reported. The CNT films were fabricated by coating gels, which were prepared by dispersing CNTs in low-molecular-weight poly(ethylene glycol) (PEG) through mechanical grinding and subsequent ultrasonication, on fluorine tin oxide (FTO) glass. PEG was removed from the CNT films through heating. These binder-free CNT films were rough and exhibited good adhesion to substrates. They were used as the counter electrode of DSCs. The DSCs with SWCNT or MWCNT counter electrodes exhibited a light-to-electricity conversion efficiency comparable with that with the conventional platinum (Pt) counter electrode, when the devices were tested immediately after device fabrication. The DSCs with an SWCNT counter electrode exhibited good stability in photovoltaic performance. The efficiency did not decrease after four weeks. On the other hand, DSCs with the MWCNT or Pt counter electrode exhibited a remarkable decrease in the photovoltaic efficiency after four weeks. The high photovoltaic performance of these DSCs is related to the excellent electrochemical catalysis of CNTs on the redox of the iodide/triiodide pair, as revealed by the cyclic voltammetry and ac impedance spectroscopy.

18.
ACS Appl Mater Interfaces ; 12(11): 13013-13020, 2020 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-32097550

RESUMO

Thermoelectric (TE) materials are important for sustainable development because they can directly convert heat into electricity. Compared with inorganic TE materials, conductive polymers have demonstrated unique benefits and their irreplaceability. But their TE properties, particularly the Seebeck coefficient, must be greatly enhanced for practical application. In this work, MXene (Ti3C2Tx), an n-type two-dimensional material, is blended into p-type poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS). The Seebeck coefficient of the composites increases with the increasing MXene loading at the MXene loading below 33 wt % and then decreases with further increasing of the MXene loading. MXene can enhance the Seebeck coefficient from 23 up to 57.3 µV K-1 and the power factor from 44.1 up to 155 µW m-1 K-2. For the first time, enhancement in the Seebeck coefficient of a p-type TE polymer by an n-type filler has been achieved. Enhancement in the Seebeck coefficient is ascribed to energy filtering of charge carriers by the internal electric field arising from the electron transfer from MXene to PEDOT:PSS. The internal electric field can filter the charge carriers with low energy and thus enhance the Seebeck coefficient.

19.
Nat Commun ; 11(1): 4683, 2020 09 17.
Artigo em Inglês | MEDLINE | ID: mdl-32943621

RESUMO

Wearable dry electrodes are needed for long-term biopotential recordings but are limited by their imperfect compliance with the skin, especially during body movements and sweat secretions, resulting in high interfacial impedance and motion artifacts. Herein, we report an intrinsically conductive polymer dry electrode with excellent self-adhesiveness, stretchability, and conductivity. It shows much lower skin-contact impedance and noise in static and dynamic measurement than the current dry electrodes and standard gel electrodes, enabling to acquire high-quality electrocardiogram (ECG), electromyogram (EMG) and electroencephalogram (EEG) signals in various conditions such as dry and wet skin and during body movement. Hence, this dry electrode can be used for long-term healthcare monitoring in complex daily conditions. We further investigated the capabilities of this electrode in a clinical setting and realized its ability to detect the arrhythmia features of atrial fibrillation accurately, and quantify muscle activity during deep tendon reflex testing and contraction against resistance.


Assuntos
Condutividade Elétrica , Epiderme , Monitorização Fisiológica/instrumentação , Movimento (Física) , Pele , Artefatos , Impedância Elétrica , Eletrocardiografia/instrumentação , Eletrocardiografia/métodos , Eletrodos , Eletroencefalografia/instrumentação , Eletroencefalografia/métodos , Eletromiografia/instrumentação , Eletromiografia/métodos , Desenho de Equipamento , Humanos , Monitorização Fisiológica/métodos , Polímeros/química , Sorbitol
20.
Nanoscale ; 11(7): 3216-3221, 2019 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-30706930

RESUMO

The grain size and quality of hybrid organic-inorganic perovskite (HOIP) films greatly affect the performance of perovskite solar cells (PSCs). However, dripping an anti-solvent during the spin coating process induces rapid nucleation and reduces the grain size. Here, a facile method is developed to engineer clusters in precursor solution and obtain high-quality perovskite films with an enlarged grain size. A cluster interfacial modifier, chlorobenzene (CB), is added to precursor solution. The modifier increases the interfacial energy between the precursor cluster and the solvent. The increased interfacial energy suppresses the nucleation and gives rise to HOIP films with large grains and high crystallinity. The efficiency of PSCs based on this method is greatly improved from 17.55% to 19.5%.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA