RESUMO
PURPOSE: This ex vivo study aimed to compare a newly developed dual-source photon-counting CT (PCCT) with a 3rd generation dual-source dual-energy CT (DECT) for the detection and measurement (stone lengths and volumetrics) of urinary stones. METHODS: 143 urinary stones with a known geometry were physically measured and defined as reference values. Next, urinary stones were placed in an anthropomorphic abdomen-model and were scanned with DECT and PCCT. Images were read by two experienced examiners and automatically evaluated using a specific software. RESULTS: DECT and PCCT showed a high sensitivity for manual stone detection of 97.9% and 94.4%, and for automatic detection of 93.0% and 87.4%, respectively. Compared to that uric acid and xanthine stones were recognized slightly worse by DECT and PCCT with manual stone detection (93.3% and 82.2%), and with automatic detection (77.8% and 60.0%). All other stone entities were completely recognized. By comparing the maximum diameter of the reference value and DECT, Pearson-correlation was 0.96 (p < 0.001) for manual and 0.97 (p < 0.001) for automatic measurement, and for PCCT it was 0.94 (p < 0.001) for manual and 0.97 (p < 0.001) for automatic measurements. DECT and PCCT can also reliably determine volume manually and automatically with a Pearson-correlation of 0.99 (p < 0.001), respectively. CONCLUSION: Both CTs showed comparable results in stone detection, length measurement and volumetry compared to the reference values. Automatic measurement tends to underestimate the maximum diameter. DECT proved to be slightly superior in the recognition of xanthine and uric acid stones.
Assuntos
Cálculos Renais , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Cálculos Renais/diagnóstico por imagem , Cálculos Renais/química , Cálculos Renais/patologia , Fótons , Ácido Úrico/análiseRESUMO
PURPOSE: Preliminary dual-energy CT studies have shown that low-energy virtual monoenergetic (VMI) + reconstructions can provide superior image quality compared to standard 120 kV CTA series. The purpose of this study is to evaluate the impact of low-energy VMI reconstructions on quantitative and qualitative image quality, vascular contrast, and diagnostic assessability of the carotid artery in patients undergoing photon-counting CTA examinations. MATERIALS AND METHODS: A total of 122 patients (67 male) who had undergone dual-source photon-counting CTA scans of the carotid artery were retrospectively analyzed in this study. Standard 120 kV CT images and low-keV VMI series from 40 to 100 keV with an interval of 15 keV were reconstructed. Quantitative analyses included the evaluation of vascular CT numbers, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). CT number measurements were performed in the common, external, and internal carotid arteries. Qualitative analyses were performed by three board-certified radiologists independently using five-point scales to evaluate image quality, vascular contrast, and diagnostic assessability of the carotid artery. RESULTS: Mean attenuation, CNR and SNR values were highest in 40 keV VMI reconstructions (HU, 1362.32 ± 457.81; CNR, 33.19 ± 12.86; SNR, 34.37 ± 12.89) followed by 55-keV VMI reconstructions (HU, 736.94 ± 150.09; CNR, 24.49 ± 7.11; SNR, 26.25 ± 7.34); all three mean values at these keV levels were significantly higher compared with the remaining VMI series and standard 120 kV CT series (HU, 154.43 ± 23.69; CNR, 16.34 ± 5.47; SNR, 24.44 ± 7.14) (p < 0.0001). The qualitative analysis showed the highest rating scores for 55 keV VMI reconstructions followed by 40 keV and 70 keV VMI series with a significant difference compared to standard 120 kV CT images series regarding image quality, vascular contrast, and diagnostic assessability of the carotid artery (all comparisons, p < 0.01). CONCLUSIONS: Low-keV VMI reconstructions at a level of 40-55 keV significantly improve image quality, vascular contrast, and the diagnostic assessability of the carotid artery compared with standard CT series in photon-counting CTA.
RESUMO
OBJECTIVES: To investigate the effect of a device-assisted suction against resistance Mueller maneuver (MM) on transient interruption of contrast (TIC) in the aorta and pulmonary trunk (PT) on computed tomography pulmonary angiogram (CTPA). METHODS: In this prospective single-center study, 150 patients with suspected pulmonary artery embolism were assigned randomly with two different breathing maneuvers (Mueller maneuver (MM) or standard end-inspiratory breath-hold command (SBC)) during routine CTPA. The MM was performed using a patented prototype (Contrast Booster™) which allows both the patient by means of visual feedback and the medical staff in the CT scanning room to monitor whether the patient is sucking sufficiently or not. Mean Hounsfield attenuation in descending aorta and PT was measured and compared. RESULTS: Overall, patients with MM showed an attenuation of 338.24 HU in the pulmonary trunk, compared to 313.71 HU in SBC (p = 0.157). In the aorta, the values for MM were lower compared to SBC (134.42 HU vs. 177.83 HU, p = 0.001). The TP-aortic ratio was significantly higher in the MM group at 3.86 compared to the SBC group at 2.26, p = 0.001. TIC phenomenon was absent in the MM group, whereas it was present in 9 patients (12.3%) in the SBC group (p = 0.005). Overall contrast was better on all levels for MM (p < 0.001). The presence of breathing artifacts was higher in the MM group (48.1% vs. 30.1%, p = 0.038), without clinical consequence. CONCLUSIONS: Performing the MM with the application of the prototype is an effective way of preventing the TIC phenomenon during i.v. contrast-enhanced CTPA scanning compared to the standard end-inspiratory breathing command. CLINICAL RELEVANCE: Compared to standard end-inspiratory breathing command, the device-assisted Mueller maneuver (MM) improves contrast enhancement and prevents the transient interruption of contrast (TIC) phenomenon in CTPA. Therefore, it may offer optimized diagnostic workup and timely treatment for patients with pulmonary embolism. KEY POINTS: ⢠Transient interruption of contrast (TIC) may impair image quality in CTPA. ⢠Mueller Maneuver using a device prototype could lower the rate of TIC. ⢠Device application in clinical routine may increase diagnostic accuracy.
Assuntos
Embolia Pulmonar , Tomografia Computadorizada por Raios X , Humanos , Sucção , Estudos Prospectivos , Tomografia Computadorizada por Raios X/métodos , Artéria Pulmonar/diagnóstico por imagem , Embolia Pulmonar/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Meios de ContrasteRESUMO
OBJECTIVES: Photon-counting computed tomography has lately found its way into clinical routine. The new technique could offer substantial improvements regarding general image quality, image noise, and radiation dose reduction. This study evaluated the first abdominal examinations in clinical routine and compared the results to conventional computed tomography. METHODS: In this single-center retrospective study, 66 patients underwent photon-counting and conventional abdominal CT. Four radiologists assessed general image quality, image noise, and image artifacts. Signal-to-noise ratio and dose properties of both techniques within the clinical application were compared. An ex vivo phantom study revealed the radiobiological impact by means of DNA double-strand break foci in peripheral blood cells by enumerating γ-H2AX+53BP1 foci. RESULTS: General image quality in accordance with the Likert scale was found superior for photon-counting CT (4.74 ± 0.46 vs. 4.25 ± 0.54; p < 0.001). Signal-to-noise ratio (p < 0.001) and also dose exposure were higher for photon-counting CT (DLP: 419.2 ± 162.2 vs. 372.3 ± 236.6 mGy*cm; p = 0.0435). CT exposure resulted in significantly increased DNA damage in comparison to sham control (p < 0.001). Investigation of the average foci per cell and radiation-induced foci numbers revealed significantly elevated numbers (p = 0.004 and p < 0.0001, respectively) after photon-counting CT. CONCLUSION: Photon-counting CT in abdominal examinations showed superior results regarding general image quality and signal-to-noise ratio in clinical routine. However, this seems to be traded for a significantly higher dose exposure and corresponding double-strand break frequency. Optimization of standard protocols in further clinical applications is required to find a compromise regarding picture quality and dose exposure. KEY POINTS: ⢠Photon-counting computed tomography promises to enhance the diagnostic potential of medical imaging in clinical routine. ⢠Retrospective single-center study showed superior general image quality accompanied by higher dose exposure in initial abdominal PCCT protocols compared to state-of-the-art conventional CT. ⢠A simultaneous ex vivo phantom study revealed correspondingly increased frequencies of DNA double-strand breaks after PCCT.
Assuntos
DNA , Tomografia Computadorizada por Raios X , Humanos , Estudos Retrospectivos , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Razão Sinal-Ruído , Imagens de FantasmasRESUMO
OBJECTIVES: Computed tomography (CT) is employed to evaluate surgical outcome after spinal interventions. Here, we investigate the potential of multispectral photon-counting computed tomography (PC-CT) on image quality, diagnostic confidence, and radiation dose compared to an energy-integrating CT (EID-CT). METHODS: In this prospective study, 32 patients underwent PC-CT of the spine. Data was reconstructed in two ways: (1) standard bone kernel with 65-keV (PC-CTstd) and (2) 130-keV monoenergetic images (PC-CT130 keV). Prior EID-CT was available for 17 patients; for the remaining 15, an age-, sex-, and body mass index-matched EID-CT cohort was identified. Image quality (5-point Likert scales on overall, sharpness, artifacts, noise, diagnostic confidence) of PC-CTstd and EID-CT was assessed by four radiologists independently. If metallic implants were present (n = 10), PC-CTstd and PC-CT130 keV images were again assessed by 5-point Likert scales by the same radiologists. Hounsfield units (HU) were measured within metallic artifact and compared between PC-CTstd and PC-CT130 keV. Finally, the radiation dose (CTDIvol) was evaluated. RESULTS: Sharpness was rated significantly higher (p = 0.009) and noise significantly lower (p < 0.001) in PC-CTstd vs. EID-CT. In the subset of patients with metallic implants, reading scores for PC-CT130 keV revealed superior ratings vs. PC-CTstd for image quality, artifacts, noise, and diagnostic confidence (all p < 0.001) accompanied by a significant increase of HU values within the artifact (p < 0.001). Radiation dose was significantly lower for PC-CT vs. EID-CT (mean CTDIvol: 8.83 vs. 15.7 mGy; p < 0.001). CONCLUSIONS: PC-CT of the spine with high-kiloelectronvolt reconstructions provides sharper images, higher diagnostic confidence, and lower radiation dose in patients with metallic implants. KEY POINTS: ⢠Compared to energy-integrating CT, photon-counting CT of the spine had significantly higher sharpness and lower image noise while radiation dose was reduced by 45%. ⢠In patients with metallic implants, virtual monochromatic photon-counting images at 130 keV were superior to standard reconstruction at 65 keV in terms of image quality, artifacts, noise, and diagnostic confidence.
Assuntos
Doenças da Coluna Vertebral , Tomografia Computadorizada por Raios X , Humanos , Imagens de Fantasmas , Fótons , Estudos Prospectivos , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Coluna Vertebral/diagnóstico por imagem , Doenças da Coluna Vertebral/diagnóstico por imagemRESUMO
PURPOSE: Endoleaks are a common complication after endovascular aortic repair (EVAR) and thoracic endovascular aortic repair (TEVAR). The detection and correct classification of endoleaks is essential for the further treatment of affected patients. However, standard computed tomography angiography (CTA) provides no hemodynamic information on endoleaks, which can result in misclassification in complex cases. The aim of this study was to compare standard CTA (sCTA) with dynamic, dual-energy CTA (dCTA) for detection and classification of endoleaks following EVAR or TEVAR. MATERIALS AND METHODS: This retrospective evaluation compared 69 sCTA diagnostic examinations performed on 50 different patients with 89 dCTA diagnostic examinations performed on 69 different patients. RESULTS: In total, 15.9% of sCTA examinations and 49.4% of dCTA examinations led to the detection of endoleaks. With sCTA, 20.0% of patients were diagnosed with endoleaks, while with dCTA, 37.7% of patients were diagnosed with endoleaks. With sCTA, mainly Type 1 endoleaks were detected, whereas, with dCTA, the types of detected endoleaks were more evenly distributed. In comparison with the literature, the frequencies of endoleak types detected with dCTA better reflect the natural distribution than the frequencies detected with standard CTA. CONCLUSION: Based on the retrospective comparative evaluation, dCTA could pose a valuable supplementary diagnostic tool resulting in a more accurate and realistic detection and classification of suspected endoleaks.
Assuntos
Aneurisma da Aorta Abdominal , Procedimentos Endovasculares , Humanos , Angiografia por Tomografia Computadorizada/efeitos adversos , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Correção Endovascular de Aneurisma , Meios de Contraste , Estudos Retrospectivos , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/complicações , Resultado do Tratamento , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/métodos , Aortografia/métodosRESUMO
BACKGROUND: We investigated the feasibility of evaluating coronary arteries with a contrast-enhanced (CE) self-navigated sparse isotropic 3D whole heart T1-weighted magnetic resonance imaging (MRI) study sequence. METHODS: A total of 22 consecutive patients underwent coronary angiography and/or cardiac computed tomography (CT) including cardiac MRI. The image quality was evaluated on a 3-point Likert scale. Inter-reader variability for image quality was analyzed with Cohen's kappa for the main coronary segments (left circumflex [LCX], left anterior descending [LAD], right coronary artery [RCA]) and the left main trunk (LMT). RESULTS: Inter-reader agreement for image quality of the coronary tree ranged from substantial to perfect, with a Cohen's kappa of 0.722 (RCAmid) to 1 (LCXprox). The LMT had the best image quality. Image quality of the proximal vessel segments differed significantly from the mid- and distal segments (RCAprox vs. RCAdist, pâ¯< 0.05). The LCX segments showed no significant difference in image quality along the vessel length (LCXprox vs. LCXdist, pâ¯= n.s.). The mean acquisition time for the study sequence was 553â¯s (±46â¯s). CONCLUSION: Coronary imaging with a sparse 3D whole-heart sequence is feasible in a reasonable amount of time producing good-quality imaging. Image quality was poorer in distal coronary segments and along the entire course of the LCX.
Assuntos
Vasos Coronários , Coração , Humanos , Vasos Coronários/diagnóstico por imagem , Angiografia Coronária , Imageamento por Ressonância Magnética , Imageamento TridimensionalRESUMO
BACKGROUND. CT-based criteria for assessing the gastrointestinal stromal tumor (GIST) response to tyrosine kinase inhibitor (TKI) therapy are limited in part because tumor attenuation is influenced by treatment-related changes including hemorrhage and calcification. The iodine concentration may be less impacted by such changes. OBJECTIVE. The purpose of this study was to determine whether the dual-energy CT (DECT) vital iodine tumor burden (TB) allows improved differentiation between treatment responders and nonresponders among patients with metastatic GIST who are undergoing TKI therapy compared with established CT and PET/CT criteria. METHODS. An anthropomorphic phantom with spherical inserts mimicking GIST lesions of varying iodine concentrations and having nonenhancing central necrotic cores underwent DECT to determine a threshold iodine concentration. Forty patients (25 women and 15 men; median age, 57 years) who were treated with TKI for metastatic GIST were retrospectively evaluated. Patients underwent baseline and follow-up DECT and FDG PET/CT. Response assessment was performed using RECIST 1.1, modified Choi (mChoi) criteria, vascular tumor burden (VTB) criteria, DECT vital iodine TB criteria, and European Organization for Research and Treatment of Cancer (EORTC) PET criteria. DECT vital iodine TB criteria used the same percentage changes as RECIST 1.1 response categories. Progression-free survival was compared between responders and nonresponders for each response criterion by use of Cox proportional hazard ratios and Harrell C-indexes (i.e., concordance indexes). RESULTS. The phantom experiment identified a threshold of 0.5 mg/mL to differentiate vital from nonvital tissue. With use of the DECT vital iodine TB, median progression-free survival was significantly different between responders and nonresponders (623 vs 104 days; p < .001).. For nonresponders versus responders, the hazard ratio for disease progression for DECT vital iodine TB was 6.9 versus 7.6 for EORTC PET criteria, 3.3 for VTB criteria, 2.3 for RECIST 1.1, and 2.1 for mChoi criteria. The C-index was 0.74 for EORTC PET criteria, 0.73 for DECT vital iodine TB criteria, 0.67 for VTB criteria, 0.61 for RECIST 1.1, and 0.58 for mChoi criteria. The C-index was significantly greater for DECT vital iodine TB criteria than for RECIST 1.1 (p = .02) and mChoi criteria (p = .002), but it was not different from that for VTB and EORTC PET criteria (p > .05). CONCLUSION. DECT vital iodine TB criteria showed performance comparable to that of EORTC PET criteria and outperformed RECIST 1.1 and mChoi criteria for response assessment of metastatic GIST treated with TKI therapy. CLINICAL IMPACT. DECT vital iodine TB could help guide early management decisions in patients receiving TKI therapy.
Assuntos
Tumores do Estroma Gastrointestinal , Iodo , Segunda Neoplasia Primária , Feminino , Fluordesoxiglucose F18 , Tumores do Estroma Gastrointestinal/diagnóstico por imagem , Tumores do Estroma Gastrointestinal/tratamento farmacológico , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Carga TumoralRESUMO
OBJECTIVE: Needle decompression of tension pneumothorax in children is a rarely encountered but potentially life-saving procedure, that is accompanied by a certain risk of injury. We evaluated the nipple as a landmark for an alternative anterior insertion site and as an aid in localizing lateral insertion sites, as well as its influence on the safety profile of the procedure. METHODS: In thoracic computer tomography scans of children aged 0-10 years, the distance to the closest vital structure was compared between the traditional anterior insertion site (2nd intercostal space midclavicular line) and an alternative anterior insertion site (2nd intercostal space at the nipple line). Furthermore, the level of the nipple at the midaxillary line was investigated as guidance in quickly localizing the lateral insertion site and ensuring an insertion site high enough to avoid intraabdominal injury by the decompression needle. Additionally, correlation of these measures with age was investigated. RESULTS: The distance to the closest vital structure at the 2nd intercostal space was significantly bigger at the nipple line compared to the midclavicular line (right: 2.23 ± 1.13 cm vs. 0.99 ± 0.80 cm, p < 0.0001; left: 1.92 ± 1.19 cm vs. 0.81 ± 0.70 cm, p < 0.0001). At the midaxillary line, the level of the nipple was at the 4th or 5th intercostal space in the majority of children (right: 83.8%; left: 88.1%). The mean distance from the nipple to the diaphragmatic cupola was 2.63 ± 1.85 cm on the right and 3.40 ± 1.86 cm on the left hemithorax. CONCLUSION: When performing anterior needle decompression in children, we recommend inserting the needle at the more lateral insertion site at the 2nd intercostal space at the nipple line. At the lateral decompression sites, the nipple can be used as a marker for localizing the correct intercostal space for insertion and thereby ensuring enough caudad distance to the diaphragm to avoid abdominal injury.
Assuntos
Serviços Médicos de Emergência , Pneumotórax , Criança , Pré-Escolar , Descompressão Cirúrgica/métodos , Serviços Médicos de Emergência/métodos , Humanos , Lactente , Recém-Nascido , Agulhas , Mamilos/cirurgia , Pneumotórax/diagnóstico por imagem , Pneumotórax/cirurgia , Toracostomia/métodos , Tomografia Computadorizada por Raios XRESUMO
BACKGROUND: Thromboembolic complications such as ischemic stroke or peripheral arterial thromboembolism are known complications in hypertrophic cardiomyopathy (HCM). We sought to assess the clinical and cardiovascular magnetic resonance (CMR) characteristics of patients with HCM suffering from thromboembolic events and analyzed the predictors of these unfavorable outcomes.MethodsâandâResults:The 115 HCM patients underwent late gadolinium enhanced (LGE) CMR and were included in the study. Follow-up was 5.6±3.6 years. The primary endpoint was the occurrence of thromboembolic events (ischemic stroke or peripheral arterial thromboembolism). It occurred in 17 (14.8%) patients (event group, EG), of whom 64.7% (11) were men. During follow-up, 10 (8.7%) patients died. Patients in the EG showed more comorbidities, such as heart failure (EG 41.2% vs. NEG (non-event group) 14.3%, P<0.01) and atrial fibrillation (AF: EG 70.6% vs. NEG 36.7%, P<0.01). Left atrial end-diastolic volume was significantly higher in the EG (EG 73±24 vs. NEG 50±33 mL/m2, P<0.01). Both the presence and extent of LGE were enhanced in the EG (extent% EG 23±15% vs. NEG 8±9%, P<0.0001). No patient without LGE experienced a thromboembolic event. Multivariate analysis revealed AF and LGE extent as independent predictors. CONCLUSIONS: LGE extent (>14.4%) is an independent predictor for thromboembolic complications in patients with HCM and might therefore be considered as an important risk marker. The risk for thromboembolic events is significantly elevated if accompanied by AF.
Assuntos
Fibrilação Atrial/complicações , Cardiomiopatia Hipertrófica/diagnóstico por imagem , Meios de Contraste/administração & dosagem , Imagem Cinética por Ressonância Magnética , Meglumina/administração & dosagem , Compostos Organometálicos/administração & dosagem , Tromboembolia/etiologia , Adulto , Idoso , Fibrilação Atrial/diagnóstico , Cardiomiopatia Hipertrófica/complicações , Cardiomiopatia Hipertrófica/mortalidade , Cardiomiopatia Hipertrófica/patologia , Feminino , Fibrose , Humanos , Masculino , Pessoa de Meia-Idade , Miocárdio/patologia , Valor Preditivo dos Testes , Prognóstico , Medição de Risco , Fatores de Risco , Tromboembolia/diagnóstico , Tromboembolia/mortalidade , Fatores de TempoRESUMO
BACKGROUND: One main challenge in pediatric imaging is to reduce motion artifacts by calming young patients. To that end, the Radiological Society of North America (RSNA) as early as 1997 stated the necessity of adults accompanying their child during the child's examination. Nonetheless, current research lacks data regarding radiation dose to these chaperones. OBJECTIVE: The aim of this study was to measure the radiation dose of accompanying adults during state-of-the-art pediatric CT protocols. MATERIALS AND METHODS: In addition to a 100-kV non-contrast-enhanced chest CT (Protocol 1), we performed a 70-kV contrast-enhanced chest protocol (Protocol 2) using a third-generation dual-source CT. We acquired data on the radiation dose around the scanner using digital dosimetry placed right at the gantry, 1 m away, as well as beside the gantry. We acquired the CT-surrounding radiation dose during scanning of a pediatric phantom as well as 12 pediatric patients. RESULTS: After conducting 10 consecutive phantom scans using Protocol 1, we found the location with the highest cumulative dose acquired was right next to the gantry opening, at 3 µSv. Protocol 2 showed highest cumulative dose of 2 µSv at the same location. For Protocol 1, the location with the highest radiation doses during pediatric scans was right next to the gantry opening, with doses of 0.75±0.70 µSv. For Protocol 2, the highest radiation was measured 1 m away at 0.50±0.60 µSv. No radiation dose was measured at any time beside the gantry. CONCLUSION: Our results provide proof that chaperones receive low radiation doses during state-of-the-art CT examinations. Given knowledge of these values as well as the optimal spots with the lowest radiation doses, parents as well as patients might be more relaxed during the examination.
Assuntos
Acompanhantes Formais em Exames Físicos , Doses de Radiação , Tomografia Computadorizada por Raios X , Adulto , Criança , Meios de Contraste , Feminino , Humanos , Masculino , Imagens de Fantasmas , Monitoramento de RadiaçãoRESUMO
BACKGROUND: Photon-counting detector (PCD) computed tomography (CT) allows for the reconstruction of virtual monoenergetic images (VMI) at different thresholds. OBJECTIVE: The aim of our study was to evaluate the optimal arterial contrast in portal venous (pv) scans regarding objective parameters and subjective image quality for different virtual keV levels. METHODS: We identified 40 patients that underwent a CT scan with an arterial and pv phase on a PCD-CT (NAEOTOM alpha, Siemens Healthineers, Forchheim, Germany). The attenuation of abdominal arteries on pv phases was measured for different virtual keV levels in a monoenergetic+ application profile and for polychromatic (pc) arterial images. Two independent readers assessed subjective image quality, including vascular contrast in pv scans at different energy levels. Additionally, signal- and contrast-to-noise ratios (SNR and CNR) were measured. RESULTS: Our results showed increasing arterial attenuation levels with decreasing energy levels in virtual monoenergetic imaging on pv scans with the highest attenuation at 40 keV, significantly higher than in the pc arterial phase (439 ± 97 HU vs. 360 ± 97, p < 0.001). Noise, SNR, and CNR were worse at this energy level (p < 0.001). Pv VMI showed less noise at energy levels above 70 keV (all p < 0.001). Subjective image quality was rated best at 70 keV, vascular contrast was best at 40 keV. CONCLUSIONS: Our research suggests that virtual monoenergetic images at 40 keV in Mono+ mode derived from a PCD-CT can be a feasible alternative to a true arterial phase for assessment of vessels with worse CNR and SNR.
RESUMO
PURPOSE: Aim of the recent study is to point out a method to optimize quality of CT scans in oncological patients with port systems. This study investigates the potential of photon counting computed tomography (PCCT) for reduction of beam hardening artifacts caused by port-implants in chest imaging by means of spectral reconstructions. METHOD: In this retrospective single-center study, 8 ROIs for 19 spectral reconstructions (polyenergetic imaging, monoenergetic reconstructions from 40 to 190 keV as well as iodine maps and virtual non contrast (VNC)) of 49 patients with pectoral port systems undergoing PCCT of the chest for staging of oncologic disease were measured. Mean values and standard deviation (SD) Hounsfield unit measurements of port-chamber associated hypo- and hyperdense artifacts, bilateral muscles and vessels has been carried out. Also, a structured assessment of artifacts and imaging findings was performed by two radiologists. RESULTS: A significant association of keV with iodine contrast as well as artifact intensity was noted (all p < 0.001). In qualitative assessment, utilization of 120 keV monoenergetic reconstructions could reduce severe and pronounced artifacts completely, as compared to lower keV reconstructions (p < 0.001). Regarding imaging findings, no significant difference between monoenergetic reconstructions was noted (all p > 0.05). In cases with very high iodine concentrations in the subclavian vein, image distortions were noted at 40 keV images (p < 0.01). CONCLUSIONS: The present study demonstrates that PCCT derived spectral reconstructions can be used in oncological imaging of the thorax to reduce port-derived beam-hardening artefacts. When evaluating image data sets within a staging, it can be particularly helpful to consider the 120 keV VMIs, in which the artefacts are comparatively low.
Assuntos
Artefatos , Radiografia Torácica , Tomografia Computadorizada por Raios X , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Tomografia Computadorizada por Raios X/métodos , Radiografia Torácica/métodos , Estudos Retrospectivos , Adulto , Idoso de 80 Anos ou mais , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Fótons , Reprodutibilidade dos TestesRESUMO
OBJECTIVES: The aim of this study was to analyze the extent of dental metal artifacts in virtual monoenergetic (VME) images, as they often compromise image quality by obscuring soft tissue affecting vascular attenuation reducing sensitivity in the detection of dissections. METHODS: Neck photon-counting CT datasets of 50 patients undergoing contrast-enhanced trauma CT were analyzed. Hyperattenuation and hypoattenuation artifacts, muscle with and without artifacts and vessels with and without artifacts were measured at energy levels from 40 keV to 190 keV. The corrected artifact burden, corrected image noise and artifact index were calculated. We also assessed subjective image quality on a Likert-scale. RESULTS: Our study showed a lower artifact burden and less noise in artifact-affected areas above the energy levels of 70 keV for hyperattenuation artifacts (conventional polychromatic CT images 1123 ± 625 HU vs. 70 keV VME 1089 ± 733 HU, p = 0.125) and above of 80 keV for hypoattenuation artifacts (conventional CT images -1166 ± 779 HU vs. 80 keV VME -1170 ± 851 HU, p = 0.927). Vascular structures were less hampered by metal artifacts than muscles (e.g., corrected artifact burden at 40 keV muscle 158 ± 125 HU vs. vessels -63 ± 158 HU p < 0.001), which was also reflected in the subjective image assessment, which showed better ratings at higher keV values and overall better ratings for vascular structures than for the overall artifact burden. CONCLUSIONS: Our research suggests 70 keV might be the best compromise for reducing metal artifacts affecting vascular structures and preventing vascular contrast if solely using VME reconstructions. VME imaging shows only significant effects on the general artifact burden. Vascular structures generally experience fewer metal artifacts than soft tissue due to their greater distance from the teeth, which are a common source of such artifacts.
RESUMO
Objectives: To evaluate the value of virtual monoenergetic images (VMI) from photon-counting detector CT (PCD-CT) for discriminability of severe lung injury and atelectasis in polytraumatized patients. Materials & Methods: Contrast-enhanced PCD-CT examinations of 20 polytraumatized patients with severe thoracic trauma were included in this retrospective study. Spectral PCD-CT data were reconstructed using a noise-optimized virtual monoenergetic imaging (VMI) algorithm with calculated VMIs ranging from 40 to 120 keV at 10 keV increments. Injury-to-atelectasis contrast-to-noise ratio (CNR) was calculated and compared at each energy level based on CT number measurements in severely injured as well as atelectatic lung areas. Three radiologists assessed subjective discriminability, noise perception, and overall image quality. Results: CT values for atelectasis decreased as photon energy increased from 40 keV to 120 keV (mean Hounsfield units (HU): 69 at 40 keV; 342 at 120 keV), whereas CT values for severe lung injury remained near-constant from 40 keV to 120 keV (mean HU: 42 at 40 keV; 44 at 120 keV) with significant differences at each keV level (p < 0.001). The optimal injury-to-atelectasis CNR was observed at 40 keV in comparison with the remaining energy levels (p < 0.001) except for 50 keV (p > 0.05). In line with this, VMIs at 40 keV were rated best regarding subjective discriminability. VMIs at 60-70 keV, however, provided the highest subjective observer parameters regarding subjective image noise as well as image quality. Conclusions: Discriminability between severely injured and atelectatic lung areas after thoracic trauma can be substantially improved by virtual monoenergetic imaging from PCD-CT with superior contrast and visual discriminability at 40-50 keV.
RESUMO
AIM: To evaluate the effects of lipid-lowering medications of different intensities on total, calcified, and non-calcified plaque volumes in patients undergoing serial cardiac computed tomography angiography (CCTA). METHODS: Individuals with chronic coronary syndromes from 11 centers were included in a retrospective registry. Total, calcified, and non-calcified plaque volumes were quantified and the relative difference in plaque volumes between baseline and follow-up CCTA was calculated. The intensity of lipid-lowering treatment was designated as low, moderate, or high, based on current recommendations. RESULTS: Of 216 patients (mean age 63.1 ± 9.7 years), undergoing serial CCTA (median timespan = 824.5 [IQR = 463.0-1323.0] days), 89 (41.2%) received no or low-intensity lipid-lowering medications, and 80 (37.0%) and 47 (21.8%) moderate- and high-intensity lipid-lowering agents, respectively. Progression of total and non-calcified plaque was attenuated in patients on moderate-/high- versus those on no/low-intensity treatment and arrested in patients treated with high-intensity statins or PCSK9 inhibitors (p < 0.001). Halted increase of non-calcified plaque was associated with LDL-cholesterol reduction (p < 0.001), whereas calcified plaque mass and Agatston score increased irrespective of the lipid-lowering treatment (p = NS). The intensity of lipid-lowering therapy robustly predicted attenuation of non-calcified plaque progression as a function of the time duration between the two CCTA scans, and this was independent of age and cardiovascular risk factors (HR = 3.83, 95% CI = 1.81-8.05, p < 0.001). CONCLUSION: The LOCATE multi-center observational study shows that progression of non-calcified plaques, which have been previously described as precursors of acute coronary syndromes, can be attenuated with moderate-intensity, and arrested with high-intensity lipid-lowering therapy. GERMAN CLINICAL TRIALS REGISTER: DRKS00031954.
RESUMO
PURPOSE: This study investigated the differences in subjective and objective image parameters as well as dose exposure of photon-counting CT (PCCT) compared to cone-beam CT (CBCT) in paranasal sinus imaging for the assessment of rhinosinusitis and sinonasal anatomy. METHODS: This single-centre retrospective study included 100 patients, who underwent either clinically indicated PCCT or CBCT of the paranasal sinus. Two blinded experienced ENT radiologists graded image quality and delineation of specific anatomical structures on a 5-point Likert scale. In addition, contrast-to-noise ratio (CNR) and applied radiation doses were compared among both techniques. RESULTS: Image quality and delineation of bone structures in paranasal sinus PCCT was subjectively rated superior by both readers compared to CBCT (P < .001). CNR was significantly higher for photon-counting CT (P < .001). Mean effective dose for PCCT examinations was significantly lower than for CBCT (0.038 mSv ± 0.009 vs. 0.14 mSv ± 0.011; P < .001). CONCLUSION: In a performance comparison of PCCT and a modern CBCT scanner in paranasal sinus imaging, we demonstrated that first-use PCCT in clinical routine provides higher subjective image quality accompanied by higher CNR at close to a quarter of the dose exposure compared to CBCT.
Assuntos
Seios Paranasais , Tomografia Computadorizada por Raios X , Humanos , Estudos Retrospectivos , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Tomografia Computadorizada de Feixe Cônico/métodos , Seios Paranasais/diagnóstico por imagem , Imagens de FantasmasRESUMO
BACKGROUND: Photon-counting detector computed tomography (PCD-CT) is a promising new technology with the potential to fundamentally change workflows in the daily routine and provide new quantitative imaging information to improve clinical decision-making and patient management. METHOD: The contents of this review are based on an unrestricted literature search of PubMed and Google Scholar using the search terms "photon-counting CT", "photon-counting detector", "spectral CT", "computed tomography" as well as on the authors' own experience. RESULTS: The fundamental difference with respect to the currently established energy-integrating CT detectors is that PCD-CT allows for the counting of every single photon at the detector level. Based on the identified literature, PCD-CT phantom measurements and initial clinical studies have demonstrated that the new technology allows for improved spatial resolution, reduced image noise, and new possibilities for advanced quantitative image postprocessing. CONCLUSION: For clinical practice, the potential benefits include fewer beam hardening artifacts, a radiation dose reduction, and the use of new or combinations of contrast agents. In particular, critical patient groups such as oncological, cardiovascular, lung, and head & neck as well as pediatric patient collectives benefit from the clinical advantages. KEY POINTS: · Photon-counting computed tomography (PCD-CT) is being used for the first time in routine clinical practice, enabling a significant dose reduction in critical patient populations such as oncology, cardiology, and pediatrics.. · Compared to conventional CT, PCD-CT enables a reduction in electronic image noise.. · Due to the spectral data sets, PCD-CT enables fully comprehensive post-processing applications.. CITATION FORMAT: · Hagen F, Soschynski M, Weis M etâal. Photon-counting computed tomography - clinical application in oncological, cardiovascular, and pediatric radiology. Fortschr Röntgenstr 2024; 196: 25â-â34.
Assuntos
Radiologia , Tomografia Computadorizada por Raios X , Humanos , Criança , Tomografia Computadorizada por Raios X/métodos , Meios de Contraste , Tórax , Imagens de Fantasmas , PulmãoRESUMO
PURPOSE: The novel photon-counting detector (PCD) technique acquires spectral data for virtual monoenergetic imaging (VMI) in every examination. The aim of this study was the evaluation of the impact of VMI of abdominal arterial vessels on quantitative and qualitative subjective image parameters. METHODS: A total of 20 patients that underwent an arterial phase computed tomography (CT) scan of the abdomen with a novel PCD CT (Siemens NAEOTOM alpha) were analyzed regarding attenuation at different energy levels in virtual monoenergetic imaging. Contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) were calculated and compared between the different virtual monoenergetic (VME) levels with correlation to vessel diameter. In addition, subjective image parameters (overall subjective image quality, subjective image noise and vessel contrast) were evaluated. RESULTS: Our research showed decreasing attenuation levels with increasing energy levels in virtual monoenergetic imaging regardless of vessel diameter. CNR showed best overall results at 60 keV, and SNR at 70 keV with no significant difference to 60 keV (p = 0.294). Subjective image quality was rated best at 70 keV for overall image quality, vessel contrast and noise. CONCLUSIONS: Our data suggest that VMI at 60-70 keV provides the best objective and subjective image quality concerning vessel contrast irrespective of vessel size.
RESUMO
Pectus excavatum (PE) is a congenital malformation with a funnel-shaped depression of the sternum that can lead to cardiac symptoms. However, there are patients with thoracic constriction (defined as elevated Haller-Index > 3.25 determined by cardiac magnetic resonance imaging (CMR)) without visible evidence of PE, leading to similar complaints. Between January 2004 till June 2020, patients who underwent CMR for further evaluation of the heart, due to cardiac symptoms were enrolled and compared to controls. Biventricular global strain analysis was assessed using feature tracking (CMR-FT). ECG and/or Holter recordings were performed to detect rhythm events. Cardiac symptoms were evaluated in detail using a questionnaire. Finally, 88 patients (male 35, female 53) with elevated Haller-Index (3.9 ± 0.8) were included and compared to CMR data from 25 individuals with confirmed PE and 25 healthy controls (HC). Mean age at time of CMR was 35 ± 16 years. The most common symptoms at presentation were palpitations (41%), followed by dyspnea (24%) and atypical chest pain (14%). Three patients (3%) had atrial fibrillation or atrial flutter. Concomitant phenomena were pericardial effusion in 39% and mitral valve prolapse (MVP) in 27% of the study cohort. While there were no differences in left ventricular function or volumes, right ventricular function (RVEF) was significantly lower in patients with internal PE compared to HC (RVEF (%) 50 ± 5 vs 59 ± 4, p < 0.01). Strain analysis revealed only discrete changes in RV strain, implying a purely mechanical problem in the absence of structural changes. RV dimensions were negatively correlated with the size of thoracic indices (r = 0.41), reflecting the extent of thoracic constriction. MVP was more prevalent in patients with greater thoracic indices (r = 0.24). The described cohort, referred to as internal PE because of the absence of external changes, showed similar CMR morphologic findings as patients with real PE (especially altered dimensions of the right heart and a lower RVEF). In addition, there was a high incidence of rhythm disturbances, such as extrasystoles or arrhythmias. In one-third of the study cohort additional abnormalities such as pericardial effusion or MVP were present, with MVP being found more frequently in patients with larger thoracic indices, suggesting a possible common pathogenesis.Trial registration: ISRCTN registry, ISRCTN15355937, retrospectively registered 03.06.2022, https://www.isrctn.com/ISRCTN15355937?q=15355937&filters=&sort=&offset=1&totalResults=1&page=1&pageSize=10 .