Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Anal Chem ; 94(25): 8919-8927, 2022 06 28.
Artigo em Inglês | MEDLINE | ID: mdl-35687534

RESUMO

Medical diagnostics is moving toward disease-related target detection at very low concentrations because of the (1) quest for early-stage diagnosis, at a point where only limited target amounts are present, (2) trend toward minimally invasive sample extraction, yielding samples containing low concentrations of target, and (3) need for straightforward sample collection, usually resulting in limited volume collected. Hence, diagnostic tools allowing ultrasensitive target detection at the point-of-care (POC) are crucial for simplified and timely diagnosis of many illnesses. Therefore, we developed an innovative, fully integrated, semi-automated, and economically viable platform based on (1) digital microfluidics (DMF), enabling automated manipulation and analysis of very low sample volumes and (2) low-cost disposable DMF chips with microwell arrays, fabricated via roll-to-roll processes and allowing digital target counting. Thyroid stimulating hormone detection was chosen as a relevant application to show the potential of the system. The assay buffer was selected using design of experiments, and the assay was optimized in terms of reagent concentration and incubation time toward maximum sensitivity. The hydrophobic-in-hydrophobic microwells showed an unparalleled seeding efficiency of 97.6% ± 0.6%. A calculated LOD of 0.0013 µIU/mL was obtained, showing the great potential of the platform, especially taking into account the very low sample volume analyzed (1.1 µL). Although validation (in biological matrix) and industrialization (full automation) steps still need to be taken, it is clear that the combination of DMF, low-cost DMF chips, and digital analyte counting in microwell arrays enables the implementation of ultrasensitive and reliable target detection at the POC.


Assuntos
Sistemas Automatizados de Assistência Junto ao Leito , Tireotropina , Automação , Bioensaio , Microfluídica/métodos
2.
Anal Chem ; 88(17): 8450-8, 2016 09 06.
Artigo em Inglês | MEDLINE | ID: mdl-27487722

RESUMO

Flu is caused by the influenza virus that, due to mutations, keeps our body vulnerable for infections, making early diagnosis essential. Although immuno-based diagnostic tests are available, they have low sensitivity and reproducibility. In this paper, the prospect of detecting influenza A virus using digital ELISA has been studied. To appropriately select bioreceptors for this bioassay, seven commercial antibodies against influenza A nucleoprotein were methodically tested for their reactivity and binding affinity. The study has been performed on two markedly different platforms, being an enzyme-linked immunosorbent assay and a surface plasmon resonance system. The selected antibodies displayed completely different behavior on the two platforms and in various assay configurations. Surprisingly, the antibodies that showed overall good reactivity on both platforms had the highest dissociation constant among the tested antibodies, suggesting that, although important, binding affinity is not the only parameter to be considered when selecting antibodies. Moreover, only one antibody had the capacity to capture the nucleoprotein directly in lysis buffer used for releasing this viral protein, which might pose a huge advantage when developing assays with a fast time-to-result. This antibody was implemented on an in-house developed digital ELISA platform for ultrasensitive detection of recombinant nucleoprotein, reaching a detection limit of 4 ± 1 fM in buffer and 10 ± 2 fM in 10-fold diluted nasopharyngeal swabs, which is comparable to currently available fast molecular detection techniques. These results point to a great potential for ultrasensitive immuno-based influenza detection.


Assuntos
Ensaio de Imunoadsorção Enzimática/métodos , Vírus da Influenza A/química , Proteínas de Ligação a RNA/análise , Proteínas do Core Viral/análise , Proteínas do Nucleocapsídeo , Proteínas Recombinantes/análise
3.
Anal Chem ; 86(6): 3084-91, 2014 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-24579568

RESUMO

Aptamers are emerging as powerful synthetic bioreceptors for fundamental research, diagnostics, and therapeutics. For further advances, it is important to gain a better understanding of how aptamers interact with their targets. In this work, we have used magnetic force-induced dissociation experiments to study the dissociation process of two different aptamer-protein complexes, namely for hIgE and Ara h 1. The measurements show that both complexes exhibit dissociation with two distinct regimes: the dissociation rate depends weakly on the applied force at high forces but depends stronger on force at low forces. We attribute these observations to the existence of at least one intermediate state and at least two energy barriers in the aptamer-protein interaction. The measured spontaneous dissociation rate constants were validated with SPR using both Biacore and fiber optic technology. This work demonstrates the potential of the magnetic force-induced dissociation approach for an in-depth study of the dissociation kinetics of aptamer-protein bonds, which is not possible with SPR technologies. The results will help in the development and expansion of aptamers as bioaffinity probes.


Assuntos
Aptâmeros de Nucleotídeos/química , Proteínas/química , Sequência de Bases , Ligação Proteica , Ressonância de Plasmônio de Superfície
4.
ACS Sens ; 3(2): 264-284, 2018 02 23.
Artigo em Inglês | MEDLINE | ID: mdl-29363316

RESUMO

Over the last decades, the study of cells, nucleic acid molecules, and proteins has evolved from ensemble measurements to so-called single-entity studies. The latter offers huge benefits, not only as biological research tools to examine heterogeneities among individual entities within a population, but also as biosensing tools for medical diagnostics, which can reach the ultimate sensitivity by detecting single targets. Whereas various techniques for single-entity detection have been reported, this review focuses on microfluidic systems that physically confine single targets in small reaction volumes. We categorize these techniques as droplet-, microchamber-, and nanostructure-based and provide an overview of their implementation for studying single cells, nucleic acids, and proteins. We furthermore reflect on the advantages and limitations of these techniques and highlight future opportunities in the field.


Assuntos
Técnicas Biossensoriais/métodos , Técnicas Analíticas Microfluídicas/métodos , Análise de Célula Única/métodos , Técnicas Biossensoriais/tendências , Técnicas Analíticas Microfluídicas/tendências , Ácidos Nucleicos/análise , Proteínas/análise , Análise de Célula Única/tendências
5.
Anal Chim Acta ; 1015: 74-81, 2018 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-29530254

RESUMO

The close correlation between Tau pathology and Alzheimer's disease (AD) progression makes this protein a suitable biomarker for diagnosis and monitoring of the disorder evolution. However, the use of Tau in diagnostics has been hampered, as it currently requires collection of cerebrospinal fluid (CSF), which is an invasive clinical procedure. Although measuring Tau-levels in blood plasma would be favorable, the concentrations are below the detection limit of a conventional ELISA. In this work, we developed a digital ELISA for the quantification of attomolar protein Tau concentrations in both buffer and biological samples. Individual Tau molecules were first captured on the surface of magnetic particles using in-house developed antibodies and subsequently isolated into the femtoliter-sized wells of a 2 × 2 mm2 microwell array. Combination of high-affinity antibodies, optimal assay conditions and a digital quantification approach resulted in a 24 ±â€¯7 aM limit of detection (LOD) in buffer samples. Additionally, a dynamic range of 6 orders of magnitude was achieved by combining the digital readout with an analogue approach, allowing quantification from attomolar to picomolar levels of Tau using the same platform. This proves the compatibility of the presented assay with the wide range of Tau concentrations encountered in different biological samples. Next, the developed digital assay was applied to detect total Tau levels in spiked blood plasma. A similar LOD (55 ±â€¯29 aM) was obtained compared to the buffer samples, which was 5000-fold more sensitive than commercially available ELISAs and even outperformed previously reported digital assays with 10-fold increase in sensitivity. Finally, the performance of the developed digital ELISA was assessed by quantifying protein Tau in three clinical CSF samples. Here, a high correlation (i.e. Pearson coefficient of 0.99) was found between the measured percentage of active particles and the reference protein Tau values. The presented digital ELISA technology has great capacity in unlocking the potential of Tau as biomarker for early AD diagnosis.


Assuntos
Doença de Alzheimer/sangue , Ensaio de Imunoadsorção Enzimática , Proteínas tau/sangue , Biomarcadores/sangue , Humanos
6.
Anal Chim Acta ; 1000: 191-198, 2018 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-29289308

RESUMO

The lab-on-a-chip (LOC) field has witnessed an excess of new technology concepts, especially for the point-of-care (POC) applications. However, only few concepts reached the POC market often because of challenging integration with pumping and detection systems as well as with complex biological assays. Recently, a new technology termed SIMPLE was introduced as a promising POC platform due to its features of being self-powered, autonomous in liquid manipulations, cost-effective and amenable to mass production. In this paper, we improved the SIMPLE design and fabrication and demonstrated for the first time that the SIMPLE platform can be successfully integrated with biological assays by quantifying creatinine, biomarker for chronic kidney disease, in plasma samples. To validate the robustness of the SIMPLE technology, we integrated a SIMPLE-based microfluidic cartridge with colorimetric read-out system into the benchtop Creasensor. This allowed us to perform on-field validation of the Creasensor in a single-blind study with 16 plasma samples, showing excellent agreement between measured and spiked creatinine concentrations (ICC: 0.97). Moreover, the range of clinically relevant concentrations (0.76-20 mg/dL), the sample volume (5 µL) and time-to-result of only 5 min matched the Creasensor performance with both lab based and POC benchmark technologies. This study demonstrated for the first time outstanding robustness of the SIMPLE in supporting the implementation of biological assays. The SIMPLE flexibility in liquid manipulation and compatibility with different sample matrices opens up numerous opportunities for implementing more complex assays and expanding its POC applications portfolio.


Assuntos
Creatinina/sangue , Dispositivos Lab-On-A-Chip , Técnicas Analíticas Microfluídicas , Humanos , Técnicas Analíticas Microfluídicas/instrumentação , Sistemas Automatizados de Assistência Junto ao Leito
7.
N Biotechnol ; 33(6): 755-762, 2016 Dec 25.
Artigo em Inglês | MEDLINE | ID: mdl-27318011

RESUMO

The optimal bio-functionalization of magnetic particles is essential for developing magnetic particle-based bioassays. Whereas functionalization with antibodies is generally well established, immobilization of DNA probes, such as aptamers, is not yet fully explored. In this work, four different types of commercially available magnetic particles, coated with streptavidin, maleimide or carboxyl groups, were evaluated for their surface coverage with aptamer bioreceptors, efficiency in capturing target protein and non-specific protein adsorption on their surface. A recently developed aptamer against the peanut allergen, Ara h 1 protein, was used as a model system. Conjugation of biotinylated Ara h 1 aptamer to the streptavidin particles led to the highest surface coverage, whereas the coverage of maleimide particles was 25% lower. Carboxylated particles appeared to be inadequate for DNA functionalization. Streptavidin particles also showed the greatest target capturing efficiency, comparable to the one of particles functionalized with anti-Ara h 1 antibody. The performance of streptavidin particles was additionally tested in a sandwich assay with the aptamer as a capture receptor on the particle surface. While the limit of detection obtained was comparable to the same assay system with antibody as capture receptor, it was superior to previously reported values using the same aptamer in similar assay schemes with different detection platforms. These results point to the promising application of the Ara h 1 aptamer-functionalized particles in bioassay development.


Assuntos
Aptâmeros de Nucleotídeos , Técnicas Biossensoriais/métodos , Alérgenos/análise , Alérgenos/genética , Antígenos de Plantas/análise , Antígenos de Plantas/genética , Aptâmeros de Nucleotídeos/química , Aptâmeros de Nucleotídeos/genética , Bioensaio/métodos , Biotecnologia , Glicoproteínas/análise , Glicoproteínas/genética , Humanos , Magnetismo , Proteínas de Membrana , Hipersensibilidade a Amendoim/imunologia , Proteínas de Plantas/análise , Proteínas de Plantas/genética
8.
N Biotechnol ; 32(5): 485-503, 2015 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-25813426

RESUMO

Digital microfluidics (DMF) has emerged as a promising liquid handling technology for a variety of applications, demonstrating great potential both in terms of miniaturization and automation. DMF is based on the manipulation of discrete, independently controllable liquid droplets, which makes it highly reconfigurable and reprogrammable. One of its most exclusive advantages, compared to microchannel-based microfluidics, is its ability to precisely handle solid nano- and microsized objects, such as magnetic particles. Magnetic particles have become very popular in the last decade, since their high surface-to-volume ratio and the possibility to magnetically separate them from the matrix make them perfect suitable as a solid support for bio-assay development. The potential of magnetic particles in DMF-based bio-assays has been demonstrated for various applications. In this review we discuss the latest developments of magnetic particle-based DMF bio-assays with the aim to present, identify and analyze the trends in the field. We also discuss the state-of-the art of device integration, current status of commercialization and issues that still need to be addressed. With this paper we intend to stimulate researchers to exploit and unveil the potential of these exciting tools, which will shape the future of modern biochemistry, microbiology and biomedical diagnostics.


Assuntos
Bioensaio/métodos , Magnetismo , Técnicas Analíticas Microfluídicas/instrumentação , Miniaturização
9.
ACS Appl Mater Interfaces ; 7(19): 10316-23, 2015 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-25916249

RESUMO

Aptamers are an emerging class of molecules that, because of the development of the systematic evolution of ligands by exponential enrichment (SELEX) process, can recognize virtually every target ranging from ions, to proteins, and even whole cells. Although there are many techniques capable of detecting template molecules with aptamer-based systems with high specificity and selectivity, they lack the possibility of integrating them into a compact and portable biosensor setup. Therefore, we will present the heat-transfer method (HTM) as an interesting alternative because this offers detection in a fast and low-cost manner and has the possibility of performing experiments with a fully integrated device. This concept has been demonstrated for a variety of applications including DNA mutation analysis and screening of cancer cells. To the best our knowledge, this is the first report on HTM-based detection of proteins, in this case specifically with aptamer-type receptors. For proof-of-principle purposes, measurements will be performed with the peanut allergen Ara h 1 and results indicate detection limits in the lower nanomolar regime in buffer liquid. As a first proof-of-application, spiked Ara h 1 solutions will be studied in a food matrix of dissolved peanut butter. Reference experiments with the quartz-crystal microbalance will allow for an estimate of the areal density of aptamer molecules on the sensor-chip surface.


Assuntos
Antígenos de Plantas/análise , Aptâmeros de Nucleotídeos/química , Técnicas Biossensoriais/métodos , Glicoproteínas/análise , Proteínas de Plantas/análise , Análise Serial de Proteínas/instrumentação , Receptores Artificiais/química , Termografia/métodos , Antígenos de Plantas/química , Glicoproteínas/química , Temperatura Alta , Proteínas de Membrana , Proteínas de Plantas/química , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Coloração e Rotulagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA