Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Eur J Appl Physiol ; 121(7): 1881-1888, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33713202

RESUMO

PURPOSE: There is evidence of both the preventive effects and poor acceptance of mouthguards. There are various effects on performance depending on the type of mouthguard model. Hemodynamic responses to wearing a mouthguard have not been described. The aim of this study was to investigate the effects of self-adapted mouthguards with breathing channels (SAMGvent). METHODS: In this randomized crossover study, 17 healthy, active subjects (age 25.12 ± 2.19 years) underwent body plethysmography and performed two incremental exertion tests wearing a (SAMGvent) and not wearing (CON) a mouthguard. Blood lactate, spirometrics, and thoracic impedance were measured during these maximum exercise tests. RESULTS: The mean values using a SAMGvent revealed significantly greater airway resistance compared to CON (0.53 ± 0.16 kPa·L-1 vs. 0.35 ± 0.10 kPa·L-1, respectively; p = < 0.01). At maximum load, ventilation with SAMGvent was less than CON (118.4 ± 28.17 L min-1 vs. 128.2 ± 32.16 L min-1, respectively; p = < 0.01). At submaximal loads, blood lactate responses with SAMGvent were higher than CON (8.68 ± 2.20 mmol·L-1 vs. 7.89 ± 1.65 mmol·L-1, respectively; p < 0.01). Maximum performance with a SAMGvent was 265.9 ± 59.9 W, and without a mouthguard was 272.9 ± 60.8 W (p < 0.01). Maximum stroke volume was higher using a SAMGvent than without using a mouthguard (138.4 ± 29.9 mL vs. 130.2 ± 21.2 mL, respectively; p < 0.01). CONCLUSION: Use of a self-adapted mouthguard led to increased metabolic effort and a significant reduction in ventilation parameters. Unchanged oxygen uptake may be the result of cardiopulmonary compensation and increased breathing efforts, which slightly affects performance. These results and the obvious preventive effects of mouthguards support their use in sports.


Assuntos
Resistência das Vias Respiratórias/fisiologia , Desempenho Atlético/fisiologia , Tolerância ao Exercício/fisiologia , Protetores Bucais/efeitos adversos , Adulto , Estudos Cross-Over , Impedância Elétrica , Teste de Esforço , Feminino , Hemodinâmica , Humanos , Lactatos/sangue , Masculino , Pletismografia , Espirometria
2.
Int J Dent ; 2024: 8610423, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38962723

RESUMO

The aim was to investigate the vector-cardiographic effects in patients submitted to dental extraction under local anesthesia. Twenty-one patients aged 36.6 ± 12.4 years with a clinical and radiographic indication of mandibular or maxillary tooth extraction were enrolled. The intervention was a local or mandibular nerve block anesthesia with 4% articaine hydrochloride containing epinephrine (1 : 100,000; 40 mg/ml + 10 µg/ml). Blood pressure (BP), heart rate (HR), pulse wave transit time, and vector-cardiography data were recorded throughout 3 min before and 5 min after injection. QRS- and T-wave area under the curve (QRS AUC/T AUC) were calculated from the X/Y/Z QRS-vector or T-vector. T-wave amplitude (T AM), T AUC values, and diastolic BP decreased, and HR significantly increased 4 min after injection. A transient moderate HR drop and a corresponding small increase in T AM and T AUC immediately after the injection procedure may be explained by a decreased sympathetic tone due to psychological relief. In dental anesthesia, the systemic epinephrine effects are represented by a decrease in T AUC. These effects are most pronounced in the X- and Y-leads. The 3D determination of vector planes or amplitudes is a simple method to register the sympathetic tone in local anesthesia independently of possible effects on T-wave characteristics in single leads. In conclusion, T-wave determination may help to detect even small increases in systemic adrenaline concentration in case of accidental intravascular injection. At the same time, full rhythm and spatial ischemia control is provided.

3.
J Funct Morphol Kinesiol ; 9(1)2024 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-38535432

RESUMO

Periodontal disease (PD) is considered a risk factor for cardiovascular events. However, its relationship to chronic heart failure (CHF) is unclear. The aim was to compare cardiac and inflammatory parameters in CHF patients with (PG) versus without periodontitis (NPG). The following parameters were recorded in 58 patients: periodontal screening and recording (PSR), troponin T, NT-proBNP, C-reactive protein (CRP), interleukin-6 (IL-6), blood pressure, heart rate, ejection fraction (EF), ventricular systolic and diastolic function parameters, incremental test, and three questionnaires (Mediterranean Diet Adherence Screener, MEDAS; Oral Health Impact Profile, OHIP-14; Patient Health Questionnaire, PHQ). The serum levels of NT-proBNP and troponin T were significantly higher in the PG, and the left ventricular systolic and diastolic function parameters were significantly lower. The correlation analysis showed age as the only independent risk factor for periodontitis and cardiac biomarkers. No significant group differences were found in the MEDAS, OHIP-14, and PHQ scores, or in CRP, IL-6, and cardiocirculatory parameters. Overall, the BMI correlated significantly with the mean PSR and total cholesterol. The occurrence of increased PSR together with increased age and cardiac risk parameters does not exclude an association between periodontitis and CHF, though no positive correlation was calculated. Periodontitis may be a modifiable risk factor for CHF. Its treatment may help to control the inflammatory burden.

4.
Nutrients ; 15(1)2022 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-36615693

RESUMO

In addition to drug therapy, lifestyle modification, including physical activity, and nutrition management are an integral part of current guidelines for patients with chronic heart failure (CHF). However, evidence on which clinical parameters are most influenced by nutritional behaviour, exercise capacity, or iron status is scarce. For a multicenter intervention study, we included participants with diagnosed CHF (n = 165) as well as participants with elevated NT-proBNP values and risk factors for CHF (n = 74). Cardiorespiratory fitness was tested with a bicycle test, and adherence to the Mediterranean diet (MedDiet) was assessed with the MDS questionnaire. Our data strengthened previous results confirming that the higher a person's adherence to MedDiet, the higher the cardiorespiratory fitness and the lower the body fat. Furthermore, our results showed that anemia in patients with CHF has an impact in terms of cardiorespiratory fitness, and functional outcomes by questionnaire. Since our data revealed gaps in iron supply (37.9% with iron deficiency), malnutrition (only 7.8% with high adherence to MedDiet), and both symptomatic and non-symptomatic study participants failed to meet reference values for physical performance, we encourage the enforcement of the guidelines in the treatment of CHF more strongly.


Assuntos
Dieta Mediterrânea , Insuficiência Cardíaca , Humanos , Ferro , Tolerância ao Exercício , Composição Corporal , Doença Crônica
5.
Sports Med Open ; 7(1): 64, 2021 Sep 03.
Artigo em Inglês | MEDLINE | ID: mdl-34477985

RESUMO

BACKGROUND: Some studies have suggested that a mouthguard is a performance-enhancing device due to a remote voluntary contraction. The extent to which a mouthguard can induce this phenomenon, e.g., by potentially increasing biting, has not been clarified. This study's aim was to investigate the muscular activity of the maxillary and peripheral musculature and motor performance during a rest and exercise test. METHODS: Our study comprised 12 active, male, professional young handball players (age 18.83 ± 0.39 years). Their performance, electromyographic (EMG) muscle activity (Σ), and lateral deviation (Δ) of the masticatory and peripheral musculature were measured during rest in a maximum bite force measurement, one-legged stand, a kettlebell swing exercise and a jump test while wearing a customized mouthguard (CMG) or not wearing one (Co). RESULTS: Maximum bite force measurements did not differ significantly in their mean values of muscle activity (Σ) for the masseter and temporalis muscles (Co 647.6 ± 212.8 µV vs. CMG 724.3 ± 257.1 µV p = 0.08) (Co 457.2 ± 135.5 µV vs. CMG 426.6 ± 169.3 µV p = 0.38) with versus without CMG. We found no differences in the mean activation values during a one-legged stand, the kettlebell swing, and jump test (Σ) in any of the muscles tested. Lateral deviations (Δ) wearing a CMG were significantly less in the erector spinae during the kettlebell swing (Co 5.33 ± 3.4 µV vs. CMG 2.53 ± 1.8 µV p = 0.01) and countermovement jump (Co 37.90 ± 30.6 µV vs. CMG 17.83 ± 22.3 µV p = 0.03) compared to the performance without a CMG. Jump height, rotation moment, and balance were unchanged with versus without CMG. CONCLUSION: Our results at rest and during specific motor stress show no differences with or without a CMG. The improved peripheral muscular balance while wearing a CMG indicates improved muscular stabilization.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA