1.
J Neuroeng Rehabil ; 11: 56, 2014 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-24725669

RESUMO

BACKGROUND: Monitoring joint angles through wearable systems enables human posture and gesture to be reconstructed as a support for physical rehabilitation both in clinics and at the patient's home. A new generation of wearable goniometers based on knitted piezoresistive fabric (KPF) technology is presented. METHODS: KPF single-and double-layer devices were designed and characterized under stretching and bending to work as strain sensors and goniometers. The theoretical working principle and the derived electromechanical model, previously proved for carbon elastomer sensors, were generalized to KPF. The devices were used to correlate angles and piezoresistive fabric behaviour, to highlight the differences in terms of performance between the single layer and the double layer sensors. A fast calibration procedure is also proposed. RESULTS: The proposed device was tested both in static and dynamic conditions in comparison with standard electrogoniometers and inertial measurement units respectively. KPF goniometer capabilities in angle detection were experimentally proved and a discussion of the device measurement errors of is provided. The paper concludes with an analysis of sensor accuracy and hysteresis reduction in particular configurations. CONCLUSIONS: Double layer KPF goniometers showed a promising performance in terms of angle measurements both in quasi-static and dynamic working mode for velocities typical of human movement. A further approach consisting of a combination of multiple sensors to increase accuracy via sensor fusion technique has been presented.


Assuntos
Artrometria Articular/instrumentação , Monitorização Ambulatorial/instrumentação , Humanos
2.
United European Gastroenterol J ; 3(2): 182-9, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25922679

RESUMO

BACKGROUND: There exists a wide variation in the reported incidence of coeliac disease in recent decades. We aimed to evaluate the incidence rate of coeliac diagnoses performed in an Italian region, Campania, between 2011 and 2013 and its variation therein. METHODS: All coeliac diagnoses made from 2011 to 2013 and registered within the Campania coeliac disease register (CeliacDB) were identified. Incidence rates were analysed by sex, age and province of residence, with a Poisson model fitted to determine incidence rate ratios. RESULTS: We found 2049 coeliac disease diagnoses registered in the CeliacDB between 2011 and 2013; 1441 of these patients were female (70.4%) and 1059 were aged less than 19 years (51.7%). The overall incidence of coeliac disease in Campania was 11.8 per 100,000 person-years (95% CI 11.3-12.3) during the study period, with marked variation by age [27.4 per 100,000 person-years (95% CI 25.8-29.1) in children under 19 years of age and 7.3 per 100,000 (95% CI 6.8-7.8) in adults] and sex [16.1 per 100,000 person-years in females (95% CI 15.3-16.9) and 7.2 per 100,000 person-years in males (95% CI 6.6-7.8)]. Coeliac disease incidence was roughly similar in Naples, Salerno, Caserta and Avellino, but about half in Benevento. More than 80% of our study population was diagnosed by the combination of positive antitransglutaminase IgA and Marsh 3. More than half of the patients were symptomatic at the time of coeliac disease diagnosis (39.7% had a classical presentation and 21.1% a non-classical one according to the Oslo definition). CONCLUSIONS: Coeliac disease incidence was roughly similar among Campania provinces, except in Benevento where it was about half, probably due to less awareness of coeliac disease in this area. The incidence of coeliac disease in Campania appears to be lower than that reported by most of the previous literature, suggesting the necessity of new coeliac awareness programmes.

3.
Hepatol Res ; 25(4): 355-363, 2003 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-12699845

RESUMO

BACKGROUND: Retreatment for 6 months with the association ribavirin-interferon of HCV-related chronic active hepatitis relapser patients has high probability of failure, mostly in those with genotype 1b. We evaluated the efficacy of extending the therapy from 6 to 12 months without or with the addition of amantadine. METHODS: Forty-nine genotype 1b relapser patients were treated with 3 MU of IFN-alpha2b three times per week and ribavirin 1000-1200 mg daily (double therapy). Twenty-four patients, who did not respond after 6 months of treatment, were randomized to continue for further 6 months either with the same schedule or with also the addition of amantadine 200 mg daily (triple therapy). RESULTS: A sustained virological response was observed in 15/37 subjects (41%) treated for 12 months of double therapy. In the arm of the study evaluating amantadine, end of treatment virologic response was observed in 0/12 patients of double therapy group and in 4/12 of triple therapy (P=0.09). After 6 months of follow-up, a sustained virologic response (SVR) was observed in two patients treated with the triple therapy. CONCLUSIONS: This study confirms poor results of retreatment (even if 12 months double or triple therapy) in relapser patients with HCV hepatitis, genotype 1b. No gain was obtained in prolonging from 6 to 12 months the standard double therapy, while triple therapy with amantadine as an additional regimen for this difficult subgroup of patients showed some cases of SVRs: amantadine addition deserves to be evaluated in larger trials.

4.
Artigo em Inglês | MEDLINE | ID: mdl-21095822

RESUMO

This paper focus on SFIT platforms for rehabilitations and FES therapy. Two systems will be described, one developed to support patients during motor therapy, when they are still hospitalized, and after discharge, at home; the other is a sleeve integrating multi-electrodes patches, designed to allow FES therapy and EMG acquisition for patients affected by tremor. These examples prove that it is possible to combine fabric electrodes and biomechanical textile sensors to conceive systems where gesture recognition function can be combined with EMG detection and FES capability. These platforms can be easily used at home for daily therapy, as well as for telemedicine services.


Assuntos
Reabilitação/instrumentação , Telemedicina/instrumentação , Têxteis , Terapia por Estimulação Elétrica , Eletrodos , Eletromiografia , Exercício Físico , Humanos