RESUMO
BACKGROUND: The mechanism of typical slow-fast atrioventricular nodal re-entrant tachycardia (AVNRT) and its anatomical and electrophysiological circuit inside the right atrium (RA) and Koch's Triangle (KT) are not well known. OBJECTIVE: To identify the potentials of the compact AV node and inferior extensions and to perform accurate mapping of the RA and KT in sinus rhythm (SR) and during AVNRT, to define the tachycardia circuit. METHODS: Consecutive patients with typical AVNRT were enrolled in 12 Italian centers and underwent mapping and ablation by means of a basket catheter with small electrode spacing for ultrahigh-density mapping and a modified signal-filtering toolset to record the potentials of the AV nodal structures. RESULTS: Forty-five consecutive cases of successful ablation of typical slow-fast AVNRT were included. The mean SR cycle length (CL) was 784.1 ± 6 ms and the mean tachycardia CL was 361.2 ± 54 ms. The AV node potential had a significantly shorter duration and higher amplitude in sinus rhythm than during tachycardia (60 ± 40 ms vs. 160 ± 40 ms, p < .001 and 0.3 ± 0.2 mV vs. 0.09 ± 0.12 mV, p < .001, respectively). The nodal potential duration extension was 169.4 ± 31 ms, resulting in a time-window coverage of 47.6 ± 9%. The recording of AV nodal structure potentials enabled us to obtain 100% coverage of the tachycardia CL during slow-fast AVNRT. CONCLUSION: Detailed recording of the potentials of nodal structures is possible by means of multipolar catheters for ultrahigh-density mapping, allowing 100% of the AVNRT CL to be covered. These results also have clinical implications for the ablation of right-septal and para-septal arrhythmias.
Assuntos
Ablação por Cateter , Taquicardia por Reentrada no Nó Atrioventricular , Humanos , Nó Atrioventricular/cirurgia , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Ablação por Cateter/métodos , Átrios do Coração , EletrodosRESUMO
INTRODUCTION: Limited data exist on pulsed-field ablation (PFA) in patients with persistent atrial fibrillation (PeAF) undergoing left atrial posterior wall isolation (LAPWI). METHODS: The Advanced TecHnologies For SuccEssful AblatioN of AF in Clinical Practice (ATHENA) prospective registry included consecutive patients referred for PeAF catheter ablation at 9 Italian centers, treated with the FARAPULSETM-PFA system. The primary efficacy and safety study endpoints were the acute LAPWI rate, freedom from arrhythmic recurrences and the incidence of major periprocedural complications. Patients undergoing pulmonary vein isolation (PVI) alone, PWI + LAPWI and redo procedures were compared. RESULTS: Among 249 patients, 21.7% had long-standing PeAF, 79.5% were male; mean age was 63 ± 9 years. LAPWI was performed in 57.6% of cases, with 15.3% being redo procedures. Median skin-to-skin times (PVI-only 68 [60-90] vs. PVI + LAPWI 70 [59-88] mins) did not differ between groups. 45.8% LAPWI cases were approached with a 3D-mapping system, and 37.3% with intracardiac echocardiography. LAPWI was achieved in all patients by means of PFA alone, in 88.8% cases at first pass. LAPWI was validated either by an Ultrahigh-density mapping system or by recording electrical activity + pacing maneuvers. No major complications occurred, while 2.4% minor complications were detected. During a median follow-up of 273 [191-379] days, 41 patients (16.5%) experienced an arrhythmic recurrence after the 90-day blanking period, with a mean time to recurrence of 223 ± 100 days and no differences among ablation strategies. CONCLUSION: LAPWI with PFA demonstrates feasibility, rapidity, and safety in real-world practice, offering a viable alternative for PeAF patients. LAPWI is achievable even with a fluoroscopy-only method and does not significantly extend overall procedural times.
Assuntos
Potenciais de Ação , Fibrilação Atrial , Ablação por Cateter , Frequência Cardíaca , Veias Pulmonares , Recidiva , Sistema de Registros , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Masculino , Feminino , Veias Pulmonares/cirurgia , Veias Pulmonares/fisiopatologia , Pessoa de Meia-Idade , Ablação por Cateter/efeitos adversos , Idoso , Estudos Prospectivos , Fatores de Tempo , Itália , Fatores de Risco , Átrios do Coração/fisiopatologia , Átrios do Coração/cirurgia , Resultado do Tratamento , Intervalo Livre de ProgressãoRESUMO
BACKGROUND: Highly localized impedance (LI) measurements during atrial fibrillation (AF) ablation have recently emerged as a viable real-time indicator of tissue characteristics and durability of the lesions created. We report the outcomes of acute and long-term clinical evaluation of the new DirectSense algorithm in AF ablation. METHODS: Consecutive patients undergoing AF ablation were included in the CHARISMA registry. RF delivery was guided by the DirectSense algorithm, which records the magnitude and time-course of the impedance drop. The ablation endpoint was pulmonary vein isolation (PVI), as assessed by the entrance and exit block. RESULTS: 3556 point-by-point first-pass RF applications of >10 s duration were analyzed in 153 patients (mean age=59 ± 10 years, 70% men, 61% paroxysmal AF, 39% persistent AF). The mean baseline LI was 105 ± 15 Ω before ablation and 92 ± 12 Ω after ablation (p < .0001). Both absolute drops in LI and the time to LI drop (LI drop/τ) were greater at successful ablation sites (n = 3122, 88%) than at ineffective ablation sites (n = 434, 12%) (14 ± 8 Ω vs 6 ± 4 Ω, p < .0001 for LI; 0.73 [0.41-1.25] Ω/s vs. 0.35[0.22-0.59 Ω/s, p < .0001 for LI drop/τ). No major complications occurred during or after the procedures. All PVs had been successfully isolated. During a mean follow-up of 366 ± 130 days, 18 patients (11.8%) suffered an AF/atrial tachycardia recurrence after the 90-day blanking period. CONCLUSION: The magnitude and time-course of the LI drop during RF delivery were associated with effective lesion formation. This ablation strategy for PVI guided by LI technology proved safe and effective and resulted in a very low rate of AF recurrence over 1-year follow-up.
Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Idoso , Algoritmos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Impedância Elétrica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/cirurgia , Recidiva , Resultado do TratamentoRESUMO
BACKGROUND: An early, comprehensive rhythm-control therapy is needed in order to treat atrial fibrillation (AF) effectively and to improve ablation outcomes. METHODS: A total of 153 consecutive patients from the CHARISMA registry undergoing AF ablation at eight centers were included. Patients with de novo PVI were classified as having undergone early treatment (ET) if the procedure was performed within 6 months after the first AF episode, and as having undergone delayed treatment (DT) if ablation was performed over 6 months after the first AF episode. RESULTS: One-hundred fifty-three patients were enrolled (69.9% male, 59 ± 10 years, 61.4% paroxysmal AF, 38.6% persistent AF). The time from the first AF episode to the ablation procedure was 1034 ± 1483 days. The ET group comprised 36 patients (25.3%), the DT group 60 (39.2%) and Redo cases were 57 (37.3%). During a mean follow-up of 366 ± 130 days, 18 patients (11.8%) suffered an AF/AT recurrence. More DT patients than ET patients suffered recurrences (15.7% vs. 2.2%, p = 0.0452) and the time to AT/AF recurrence was shorter in the group of patients who received an ablation treatment after 6 months (HR = 6.19, 95% CI: 1.7 to 21.9; p = 0.0474). On multivariate Cox analysis, only hypertension (HR = 4.86, 95% CI: 1.6 to 14.98, p = 0.0062) was independently associated with recurrences. Beyond the hypertension risk factor, ET was associated with a low risk of recurrence; recurrence rate ranged from 0% (ET patients without hypertension) to 25.0% (DT patients with hypertension). CONCLUSIONS: An early rhythm-control ablation therapy in the absence of common risk factors was associated with the lowest rate of recurrences.
Assuntos
Fibrilação Atrial/prevenção & controle , Fibrilação Atrial/cirurgia , Ablação por Cateter , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Sistema de RegistrosRESUMO
INTRODUCTION: Recently, a novel technology able to measure local impedance (LI) and tissue characteristics has been made available for clinical use. This analysis explores the relationships among LI and generator impedance (GI) parameters in atrial fibrillation (AF) patients. Characterization of LI among different ablation spots and procedural success were also evaluated. METHODS AND RESULTS: Consecutive patients undergoing AF ablation from the CHARISMA registry at five Italian centers were included. A novel radiofrequency (RF) ablation catheter with a dedicated algorithm (DIRECTSENSE™) was used to measure LI and to guide ablation. The ablation endpoint was pulmonary vein (PV) isolation. We analyzed 2219 ablation spots created around PVs in 46 patients for AF ablation. The mean baseline tissue impedance was 105.8 ± 14 Ω for LI versus 91.8 ± 10 Ω for GI (p < .0001). Baseline impedance was homogenous across the PV sites and proved higher in high-voltage areas than in intermediate- and low-voltage areas and the blood pool (p < .001). Both LI and GI displayed a significant drop after RF delivery, and absolute LI drop values were significantly larger than GI drop values (14 ± 8 vs. 3.7 ± 5 Ω, p < .0001). Every 5-point increment in LI drop was associated with successful ablation (odds ratio = 3.05, 95% confidence interval: 2.3-4.1, p < .0001). Conversely, GI drops were not significantly different comparing successful versus unsuccessful sites (3.7 ± 5 vs. 2.8 ± 4 Ω, p = .1099). No steam pops or major complications occurred during or after the procedures. By the end of the procedures, all PVs had been successfully isolated in all patients. CONCLUSIONS: The magnitude of the LI drop was more closely associated with effective lesion formation than the GI drop.
Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Algoritmos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Impedância Elétrica , Humanos , Projetos Piloto , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Resultado do TratamentoRESUMO
The mechanisms of atrial fibrillation (AF) induction and maintenance, including those involved in paroxysmal atrial fibrillation, are not completely known; this limits our ablation strategies and prevents us from understanding what we are actually doing when performing pulmonary vein isolation. In this report, we focus on the commonly used ablation strategies for AF and question the importance of complete pulmonary vein isolation in achieving lasting success in the ablation of AF. We also discuss in detail the absence of durable pulmonary vein isolation in patients without arrhythmic recurrences after AF ablation and the possibility to cure paroxysmal AF without concomitant pulmonary vein isolation, provocatively questioning the dogma of pulmonary vein isolation as the cornerstone of AF ablation. Finally, a prospective personalized approach in the individual patient is advocated.
Assuntos
Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Humanos , Medicina de Precisão , RecidivaRESUMO
BACKGROUND: Our aim was to evaluate the clinical outcome of paroxysmal atrial fibrillation (AF) ablation with contact force technology, using an automated lesion tagging system (VISITAGTM module) with strict criteria of catheter stability.MethodsâandâResults:We enrolled 200 consecutive patients who underwent pulmonary vein isolation (PVI) in 11 centers and were followed up for 12 months. The stability setting was within 3 mm for ≥10 s and for ≥15 s in 47% and 53% of patients, respectively. A mean of 67.2±21.9 VISITAGs was acquired. Freedom from atrial tachyarrhythmias at follow-up was 77.5% (155/200), and the contiguity between lesions was associated with a higher chronic success rate (96% vs. 77.1%; log-rank P=0.036). Radiofrequency (RF), fluoroscopy times, and recurrence rates at the 12-month follow-up were significantly lower than in a comparison group of 80 patients without VISITAGTM module (42.7±14.5 vs. 50.9±23.6 min; P=0.032; 11.6±7.8 vs. 18.4±12.8 min; P=0.003 and 22.5% vs. 41.2%; P=0.02). Two major complications (1 cardiac tamponade and 1 minor stroke) were observed only in the control group. CONCLUSIONS: Paroxysmal AF ablation with contact force technology and strict criteria of stability using the VISITAG module was a safe procedure, associated with an improvement in efficiency and a reduction of atrial tachyarrhythmia recurrence at the 12-month follow-up compared with manual annotation. Contiguity between lesions seemed to enhance effectiveness outcomes.
Assuntos
Fibrilação Atrial/terapia , Ablação por Cateter/métodos , Veias Pulmonares/fisiopatologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Ablação por Cateter/efeitos adversos , Ablação por Cateter/instrumentação , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Taquicardia/patologia , Taquicardia/prevenção & controle , Resultado do Tratamento , Adulto JovemRESUMO
The exploration of the cardiac conduction system evolved over a century, marked by groundbreaking discoveries in atrioventricular (AV) nodal physiology. Atrioventricular nodal re-entrant tachycardia (AVNRT), the most prevalent regular tachycardia in humans, remains enigmatic despite extensive research. Detailed examinations of AV nodal anatomy and histology reveal variations in location and shape, influencing electrophysiological properties. Variability in AV nodal extensions and their embryological origins contribute to the complexity of the conduction system. Physiologically, the AV node plays a crucial role in modulating AV conduction, introducing delays for ventricular filling and filtering atrial impulses. Dual-pathway physiology involving fast and slow pathways further complicates AVNRT circuitry. Integrated approaches combining pre-procedural imaging with electroanatomical mapping enhance our understanding of AV nodal structures and high-definition mapping improves precision in identifying ablation targets. Electrophysiological-anatomical correlations may unveil the specific roles of conduction axis components, aiding in the optimization of ablation strategies. This review traces the historical journey from Tawara's pioneering work to recent integrated approaches aimed at unraveling the intricacies of AV nodal structures while emphasizing the importance of a multidimensional approach, incorporating technological advancements, anatomical understanding, and clinical validation in human mapping studies.
RESUMO
Background: Typical isthmus-dependent atrial flutter (AFL) is traditionally treated through radiofrequency (RF) ablation to create a bidirectional conduction block across the cavo-tricuspid isthmus (CTI) in the right atrium. While this approach is successful in many cases, certain anatomical variations can present challenges, making CTI ablation difficult. Methods: We enrolled four patients with typical counter-clockwise AFL who displayed an epicardial bridge at the CTI. Patients underwent high-resolution mapping of the right atrium and CTI ablation. Results: Post-mapping identified areas of early focal activation outside the lesion line which suggested the presence of an epi-endocardial bridge with an endocardial breakthrough, confirmed by recording a unipolar rS pattern on electrograms at that site. A stable CTI block was achieved in all patients only after ablation at the site of the epi-endocardial breakthrough. Conclusions: The presence of an epicardial bridge at the CTI, allowing conduction to persist despite endocardial ablation, should be considered in challenging cases of CTI-dependent AFL. Understanding this phenomenon and utilizing appropriate mapping and ablation techniques are essential for achieving successful and lasting CTI block.
RESUMO
The implantation of cardiac electronic devices (CIEDs), including pacemakers and defibrillators, has become increasingly prevalent in recent years and has been accompanied by a significant rise in cardiac device infections (CDIs), which pose a substantial clinical and economic burden. CDIs are associated with hospitalizations and prolonged antibiotic therapy and often necessitate device removal, leading to increased morbidity, mortality, and healthcare costs worldwide. Approximately 1-2% of CIED implants are associated with infections, making this a critical issue to address. In this contemporary review, we discuss the burden of CDIs with their risk factors, healthcare costs, prevention strategies, and clinical management.
RESUMO
Ventricular tachycardias (VTs) and electrical storms (ES) are life-threatening conditions mostly seen in the setting of structural heart disease (SHD). Traditional management strategies, predominantly centered around pharmacological interventions with antiarrhythmic drugs, have demonstrated limited efficacy in these cases, whereas catheter ablation is related with more favorable outcomes. However, patients with hemodynamically unstable, recurrent VT or ES may present cardiogenic shock (CS) that precludes the procedure, and catheter ablation in patients with SHD portends a multifactorial intrinsic risk of acute hemodynamic decompensation (AHD), that is associated with increased mortality. In this setting, the use of mechanical circulatory support (MCS) systems allow the maintenance of end-organ perfusion and cardiac output, improving coronary flow and myocardial mechanics, and minimizing the effect of cardiac stunning after multiple VT inductions or cardioversion. Although ablation success and VT recurrence are not influenced by hemodynamic support devices, MCS promotes diuresis and reduces the incidence of post-procedural kidney injury. In addition, MCS has a role in post-procedural mortality reduction at long-term follow-up. The current review aims to provide a deep overview of the rationale and modality of MCS in patients with refractory arrhythmias and/or undergoing VT catheter ablation, underlining the importance of patient selection and timing for MCS and summarizing reported clinical experiences in this field.
RESUMO
Cardiac device infections (CDIs) are a serious complication in patients with implanted devices, resulting in increased morbidity, prolonged hospital stay, and increased healthcare costs. The effective management of these infections involves a combination of appropriate antibiotic therapy and preventive strategies aimed at reducing the risk of infection. The role of antibiotic prophylaxis in infection prevention is crucial, including the emerging use of antibiotic-supported tools and other local antibiotic delivery systems, which may reduce the risk of infection at the device implant site. In this contemporary review, we provide an overview of the prophylactic treatment and different antibiotic regimens for the treatment of CDIs, emphasizing early diagnosis, appropriate choice of antibiotics, and individualized treatment.
RESUMO
BACKGROUND: The combination of highly localized impedance (LI) and contact force (CF) may improve tissue characterization and lesion prediction during radiofrequency (RF) pulmonary vein isolation (PVI) in patients with atrial fibrillation (AF). OBJECTIVE: We report the outcomes of our acute and long-term clinical evaluation of CF-LI-guided PVI in consecutive AF ablation cases from an international multicenter clinical setting. METHODS: Three hundred twenty-four consecutive patients from 20 European centers undergoing RF catheter ablation with the Stablepoint™ catheter were enrolled in the CHARISMA registry. Of these, 275 had a minimum follow-up of 1 year and were included in the primary analysis. RESULTS: The mean procedure duration was 115 ± 47 min, and the mean fluoroscopy time was 9.9 ± 6 min. At the end of the procedures, all PVs had been successfully isolated in all study patients. Minor complications were reported in 12 patients (4.4%). At 1 year, 36 (13.1%) patients had had an AF recurrence, and freedom from antiarrhythmic drugs and AF recurrence was achieved in 228 (82.9%) patients. The recurrence rate was higher in patients with persistent AF (21/116, 18.1%) than in those with paroxysmal AF (15/159, 9.4%; p = 0.0459). On multivariate logistic analysis adjusted for baseline confounders, only time > 6 months from first diagnosis of AF to ablation (HR = 2.93, 95%CI 1.03 to 8.36, p = 0.0459) was independently associated with recurrences. CONCLUSION: An ablation strategy for PVI guided by CF-LI technology proved safe and effective and resulted in a low recurrence rate of AF over 1-year follow-up, irrespective of the underlying AF type. CLINICAL TRIAL REGISTRATION: Catheter Ablation of Arrhythmias with a High-Density Mapping System in Real-World Practice. (CHARISMA). URL: http://clinicaltrials.gov/ Identifier: NCT03793998.
RESUMO
BACKGROUND: Recent data on pulsed field ablation (PFA) for atrial fibrillation (AF) ablation suggest a progressive reduction in procedural times. Real-world data regarding the relationship between the learning curve of PFA and clinical outcomes are scarce. The objective was to evaluate the PFA learning curve and its impact on acute outcomes. METHODS: Consecutive patients undergoing AF ablation with the FARAPULSE™ PFA system were included in a prospective, non-randomized multicenter study. Procedural times were stratified on the operators' learning curve. Comparative analysis of skin-to-skin time was conducted with radiofrequency (RF) and cryoablation (CB) pulmonary vein isolation (PVI) procedures performed by the same operators in the previous year. RESULTS: Among 752 patients, 35.1% were females, and 66.9% had paroxysmal AF; mean age was 62.2 ± 10 years. A total of 62.5% of procedures were performed by operators with > 20 PFA procedures. Both time to PVI (25.6 ± 10 min vs 16.5 ± 8, p < 0.0001) and fluoroscopy time (19.8 ± 8 min vs 15.9 ± 8 min, p = 0.0045) significantly improved after 10 associated with consistent linear trend towards procedural time reduction (R2 0.92-0.68 across various procedural metrics). Current PFA skin-to-skin time was lower than the historical skin-to-skin one in 217 (62.4%) procedures; it was similar in 112 (32.2%) cases and higher than the historical skin-to-skin one in 19 (5.5%). No major complications were reported. CONCLUSIONS: In this nationwide multicentric experience, the novel PFA system proved to be fast, safe, and acutely effective in both paroxysmal and persistent AF patients. The learning curve appears to be rapid, as improvements in procedural parameters were observed after only a few procedures. CLINICAL TRIAL REGISTRATION: Advanced TecHnologies For SuccEssful AblatioN of AF in Clinical Practice (ATHENA). URL: http://clinicaltrials.gov/ Identifier: NCT05617456.
RESUMO
INTRODUCTION: Aim of this study was to compare efficacy and safety of the new ThermoCool Surround Flow® catheter (SFc) versus the ThermoCool® (TCc) in achieving persistent circumferential electrical isolation of the pulmonary veins (PVs) in patients with paroxysmal atrial fibrillation (AF). METHODS AND RESULTS: This multicenter, randomized, controlled study enrolled patients suffering from paroxysmal AF. Randomization was run in a one-to-one fashion between radiofrequency ablation by TCc or SFc. Aim of PVs ablation was documentation of electrical isolation with exit/entrance block recorded on a circular catheter. Among the 106 enrolled patients, 52 (49.0%) were randomized to TCc and 54 (51.0%) to SFc. Total volume of infused saline solution during the procedure was lower in the SFc than in TCc group (752.7 ± 268.6 mL vs 1,165.9 ± 436.2 mL, P < 0.0001). Number of identified and isolated PVs was similar in the 2 groups. Number of PVs remaining isolated 30 minutes after ablation was higher in the SFc than in TCc group (95.2% vs 90.5%, P < 0.03), mainly driven by acute ablation result in the left PVs (96.1% vs 89.7%, P < 0.04). Complications were seldom and observed only in the TCc group (0% vs 3.84%, P < 0.03). At 6-month follow-up SFc patients reported a trend toward less AF recurrences compared to those in the TCc group (22.9% vs 27.0%, P = 0.69). CONCLUSION: PV isolation by SFc lowered the rate of left PV early reconnections and reduced the volume of infused saline solution while maintaining the safety profile of AF ablation.
Assuntos
Fibrilação Atrial/cirurgia , Cateteres Cardíacos , Ablação por Cateter/instrumentação , Veias Pulmonares/cirurgia , Irrigação Terapêutica/instrumentação , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Distribuição de Qui-Quadrado , Técnicas Eletrofisiológicas Cardíacas , Desenho de Equipamento , Feminino , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Valor Preditivo dos Testes , Veias Pulmonares/fisiopatologia , Recidiva , Cloreto de Sódio/administração & dosagem , Irrigação Terapêutica/efeitos adversos , Fatores de Tempo , Resultado do TratamentoRESUMO
INTRODUCTION: Despite catheter ablation (CA) becoming an accepted treatment option for symptomatic, drug-resistant atrial fibrillation (AF), safety of this procedure continues to be cause for concern. Aim of the present multicenter registry was to assess the incidence of early CA complications and detect their predictors in a contemporary, unselected AF population METHODS AND RESULTS: From January 1, 2011 to December 31, 2011, data from 2,323 consecutive patients who underwent CA (median age 60 [52-67]; 72.3% male) for AF in 29 Italian centers were collected. All major complications occurring to the patient from admission to 30th postprocedural day were recorded. No procedure-related death was observed. Major complications occurred in 94 patients (4.0%): 50 patients (2.2%) suffered vascular access complications; 12 patients (0.5%) developed cardiac tamponade; 14 patients (0.6%) presented with pericarditis; 5 patients (0.2%) had transient ischemic attack; 4 patients had stroke; 3 patients (0.1%) had phrenic nerve paralysis; 3 patients (0.1%) had hemothorax. Other isolated but serious adverse events were documented in 3 patients (0.1%). Female gender (OR 2.643; 95% CI 1.686-4.143; P < 0.0001) and longer procedural duration (OR 2.195; 95% CI 1.388-3.473; P < 0.001) independently predicted a higher risk of complications. CONCLUSION: Major complications occurred in 4.0% of the CA procedures for AF, with vascular access complications being the most frequent events.
Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Idoso , Fibrilação Atrial/diagnóstico , Ablação por Cateter/efeitos adversos , Feminino , Humanos , Incidência , Itália/epidemiologia , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Razão de Chances , Duração da Cirurgia , Complicações Pós-Operatórias/epidemiologia , Sistema de Registros , Medição de Risco , Fatores de Risco , Fatores Sexuais , Fatores de Tempo , Resultado do TratamentoRESUMO
Atrioventricular nodal reentrant tachycardia (AVNRT) is the most frequent regular tachycardia in humans. In this review, we describe the most recent discoveries regarding the anatomical, physiological, and molecular biological features of the atrioventricular junction that could underlie the typical slow-fast AVNRT mechanisms, as these insights could lead to the proposal of a new theory concerning the circuit of this arrhythmia. Despite several models have been proposed over the years, the precise anatomical site of the reentrant circuit and the pathway involved in the slow-fast AVNRT have not been conclusively defined. One possible way to evaluate all the hypotheses regarding the nodal tachycardia circuit in humans is to map this circuit. Thus, we tried to identify the slow potential of nodal and inferior extension structures by using automated mapping of atrial activation during both sinus rhythm and typical slow-fast AVNRT. This constitutes a first step toward the definition of nodal area activation in sinus rhythm and during slow-fast AVNRT. Further studies and technical improvements in recording the potentials of the atrioventricular node structures are necessary to confirm our initial results.
Assuntos
Ablação por Cateter , Taquicardia por Reentrada no Nó Atrioventricular , Taquicardia Supraventricular , Humanos , Nó Atrioventricular , Imunoquímica , Átrios do Coração , Ablação por Cateter/métodosRESUMO
Background: Highly localized impedance (LI) measurements during atrial fibrillation (AF) ablation have the potential to act as a reliable predictor of the durability of the lesions created. Objective: We aimed to collect data on the procedural parameters affecting LI-guided ablation in a large multicenter registry. Methods: A total of 212 consecutive patients enrolled in the CHARISMA registry and undergoing their first pulmonary vein (PV) isolation for paroxysmal and persistent AF were included. Results: In all, 13,891 radiofrequency (RF) applications of ≥3â s duration were assessed. The first-pass PV isolation rate was 93.3%. A total of 80 PV gaps were detected. At successful ablation spots, baseline LI and absolute LI drop were larger than at PV gap spots (161.4 ± 19â Ω vs. 153.0 ± 13â Ω, p < 0.0001 for baseline LI; 22.1 ± 9â Ω vs. 14.4 ± 5â Ω, p < 0.0001 for LI drop). On the basis of Receiver operating characteristic curve analysis, the ideal LI drop, which predicted successful ablation, was >21â Ω at anterior sites and >18â Ω at posterior sites. There was a non-linear association between the magnitude of LI drop and contact-force (CF) (r = 0.14, 95% CI: 0.13-0.16, p < 0.0001) whereas both CF and LI drop were inversely related with delivery time (DT) (-0.22, -0.23 to -0.20, p < 0.0001 for CF; -0.27, -0.29 to -0.26, p < 0.0001 for LI drop). Conclusion: An LI drop >21â Ω at anterior sites and >18â Ω at posterior sites predicts successful ablation. A higher CF was associated with an increased likelihood of ideal LI drop. The combination of good CF and adequate LI drop allows a significant reduction in RF DT. Clinical trial registration: http://clinicaltrials.gov/, identifier: NCT03793998.
RESUMO
BACKGROUND: Intracardiac echocardiography (ICE) is increasingly employed in atrial fibrillation (AF) ablation procedures, with the potential to enhance procedural efficacy. Nevertheless, there is currently a lack of evidence assessing the impact of ICE on the efficiency, effectiveness, and safety outcomes in the context of novel pulsed-field ablation (PFA) for AF. PURPOSE: We aimed to assess whether the use of ICE could improve procedural parameters in a large population undergoing AF ablation with FARAPULSE™ catheter. METHODS: Consecutive patients who had undergone PFA of AF from nine Italian centers were included. In procedures where the ICE catheter was employed for guidance (ICE-guided group), it was used to maneuver the PFA catheter within the left atrium to achieve optimal contact with atrial structures. RESULTS: We analyzed 556 patients: 357 (66%) with paroxysmal AF, 499 (89.7%) de novo PVI. ICE-guided procedures (n = 138) were propensity matched with patients with a standard approach (n = 138), and their outcomes were compared. During ICE-guided procedures, no improvement in procedural metrics was recorded (ICE vs Standard, 23 ± 6 min vs 18.5 ± 9 min for time to PVI, p < 0.0001; 38.8 ± 7 vs 32.5 ± 5 number of PFA deliveries to achieve PVI, p < 0.0001; 68.8 ± 19 min vs 71.8 ± 29 min for primary operator time, p = 0.5301; 16.1 ± 8 min vs 18.2 ± 10 min for fluoroscopy time, p = 0.5476) except for support time (76.8 ± 26 min vs 91.4 ± 37 min, p = 0.0046). No major procedure-related adverse events were reported. CONCLUSION: Our findings confirmed that PFA could be consistently performed in a rapid, safe, and efficacious manner. The use of ICE to guide PFA was not associated with an improvement in procedural metrics.
RESUMO
BACKGROUND: Catheter ablation (CA) of atrial fibrillation (AF) is used routinely to establish rhythm control. There is mounting evidence that CA procedures should be performed during continuous oral anticoagulation and direct oral anticoagulants (DOACs) are considered the first anticoagulation strategy. Few real-life data are now available and even less in the Italian panorama. METHODS: IRIS is an Italian multicenter, non-interventional, prospective study which will be enrolled consecutive AF patients eligible for CA and treated with Rivaroxaban; patients in treatment with Rivaroxaban proceeded directly to CA while Rivaroxaban-naive patients were scheduled for CA after 4 weeks of uninterrupted anticoagulation unless the exclusion of atrial thrombi. Rivaroxaban was uninterrupted or shortly uninterrupted (<24 hours) prior CA, in line with routinely practice of each operator. Patients will be followed on continuous anticoagulation for 1 month after the ablation. The primary efficacy outcome is the cumulative incidence of all-cause death and systemic embolism while the primary safety outcome is the incidence of major bleeding events. The secondary outcomes are represented by non-major bleeding events. All events must be occurred within the first 30 days after the procedure. RESULTS: Two hundred fifty patients are expected to be enrolled and the study is estimated to be completed by the end of 2022. Up to now 56 patients have been enrolled. CONCLUSIONS: This study is the first large Italian prospective study on the management of Rivaroxaban in patients undergoing CA of AF. It aims to depict a comprehensive view of anticoagulation strategy prior CA in several Italian electrophysiology labs.