1.
BMC Oral Health ; 24(1): 173, 2024 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-38308326

RESUMO

BACKGROUND: Since color measurements are relative, the discrepancy among different instruments is alarmingly high. This multicenter study evaluated the effectiveness of instrument calibration and inter-instrument harmonization of different spectrophotometers with the same optical geometry using tooth-colored, translucent dental materials. METHODS: The coordinating center (CC) spectrophotometer was calibrated using the NPL Ceram Series II set. Two sets of 10 specimens, labeled 1 to 10 and I to X (10 mm in diameter and 1 mm thick), were tested at CC and three research sites (RS1, RS2, and RS3) using the same d/8° optical geometry spectrophotometers. Calibration factors were calculated for each material and site to obtain the average calibration factors for sets 1-10, set I-X, and the combination of both. The differences among the non-corrected and corrected reflection values were calculated using CIEDE2000 (DeltaE00) and CIELAB (DeltaEab) color difference formulas and were submitted to ANOVA and Tukey test (α = 0.05). RESULTS: A significant decrease of color differences between non-corrected as compared to corrected measurements was recorded for all CC-RS and RS-RS comparisons. The reduction of DeltaE00 values between non-corrected and corrected for CC-RS1, CC-RS2, and CC-RS3 were 83.1%, 77.2%, and 73.6%, respectively. The corresponding DeltaE00 values for RS1-RS2, RS1-RS3, and RS2-RS3 comparisons, indirectly compared in the experiment, were 84.2%, 82.8%, and 68.5%, respectively. There was a significant reduction of DeltaE00 and DeltaEab color difference for all combined RS pairs and each of three RS pairs, corrected with one of two specimen sets calibration factors separately. CONCLUSIONS: Calibration and harmonization of color measurements in dentistry using tooth-colored, translucent restorative materials significantly decreased measurement discrepancies between the coordinating center and research sites and among pairs of research sites.


Assuntos
Materiais Dentários , Odontologia , Humanos , Cor , Espectrofotometria , Teste de Materiais
2.
Clin Oral Investig ; 26(11): 6817-6827, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35882680

RESUMO

OBJECTIVES: To evaluate CIEDE2000/CIELAB differences in color (ΔE00/ΔEab), and translucency parameter (ΔTP00/ΔTPab), and gloss of gingiva-colored resin-based restorative materials upon staining/aging. MATERIALS AND METHODS: Disc-shaped, 10 mm in diameter, and 2-mm-thick samples (n = 5/group) were made from giomer (Beautifil II gingiva), oligomer-based (crea.lign GUM gel), CAD/CAM polymethyl-methacrylate-based (IvoBase CAD), PMMA-based (ProBase Hot), and dimethacrylate-based (SR Nexco Paste Gingiva). Color and gloss were recording using a benchtop spectrophotometer and gloss meter, respectively, at baseline (T0), and upon staining in coffee or red wine for 60 (T1) and 120 h (T2), or artificial aging of 150 kJ/m2 (T1) and 300 kJ/m2 (T2). Three-way analysis of variance (materials x staining conditions x time intervals), Tukey's test (α = 0.05), and Pearson's correlation test were used in analytical statistics. RESULTS: CIEDE2000 color differences ranged from 1.0 to 4.4 (coffee), 1.5 to 5.3 (wine), and 0.9 to 2.0 after artificial aging, with ΔE00 values being significantly higher for Beautifil than other materials (p < 0.05). ΔTP00 values ranged from 0.2 to 0.7 and were statistically higher upon staining in wine compared to artificial aging (p < 0.05). Gloss values at T0 were 76.7-87.0. Beautifil exhibited the lowest gloss retention (50.8-60.2%) after staining, compared to > 90% of other materials (p < 0.05). ΔE00/ΔEab and ΔTP00/ΔTPab were positively correlated (p < 0.0001). CONCLUSIONS: Color, translucency, and gloss changes of gingiva-colored restorative materials were material- and staining/aging-dependent. Generally, wine caused greatest changes in color (with IvoBase CAD being the most color stable) and translucency parameter. All materials except Beautifil gingiva II exhibited staining- and aging-dependent gloss retention greater than 90% for all compared time intervals. CLINICAL RELEVANCE: Optical properties of resin-based gingiva-colored restorative materials depend on material, staining/aging conditions, and exposure time. Certain materials should be avoided in individuals with high consumption of red wine and coffee.


Assuntos
Café , Resinas Compostas , Humanos , Gengiva , Cor , Teste de Materiais , Materiais Dentários , Coloração e Rotulagem , Propriedades de Superfície
3.
Acta Stomatol Croat ; 55(1): 2-9, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33867532

RESUMO

OBJECTIVES: To evaluate different intervals of exposure to staining solutions and artificial aging on translucency parameter (TP00) of CAD-CAM materials. MATERIAL AND METHODS: One millimeter thick square-shaped specimens (N = 288) were cut from Cerasmart (CS), IPS e.max (IE), Lava Ultimate (LU), Shofu HC (SH), Vita Enamic (VE), and Vita Suprinity (VS) and were divided into laboratory and chairside polishing. Reflection wavelength spectra, CIE D65 standard illuminant, 2 ° standard observer, SCI, UV included, SAV aperture, 6 mm diameter, were recorded at 10 nm sensitivity against white and black calibration tiles using a benchtop spectrophotometer. Subsequently, they were converted into CIEDE 2000 TP00. After baseline measurements (T0), the specimens were divided as follows (n = 8): staining in coffee (C) and wine (W), for 60 (T1) and 120 hours (T2), and accelerated artificial aging (A). Artificial aging (ISO 4892-2 standard) was performed in two cycles of 150 KJ/m2, for T1 and T2, respectively. TP measurements were repeated at T1 and T2. Data of TP00 retention were submitted to analysis of variance and Fisher's PLSD multiple comparison test (α=0.05). RESULTS: Fisher's PLSD critical differences among materials, time intervals and staining/aging were 0.16, 0.11 and 0.11, respectively. SH showed the highest TP00 followed by LU > CS > IE = VS > VE. For all time intervals, the lowest TP00 retention was observed with C. W, and A presented similar values. CONCLUSIONS: Translucency Parameter was a time and staining/aging-dependent material. In majority of cases, it decreased upon staining/aging.