Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Adv Radiat Oncol ; 9(6): 101478, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38681894

RESUMO

Purpose: Despite the increasing interest in using continuous positive airway pressure (CPAP) in radiation therapy (RT), direct comparisons with the more widely used deep inspiration breath-hold (DIBH) have been limited. This planning study aimed to offer comprehensive geometric and dosimetric evidence by comparing CPAP and DIBH-based RT plans. Materials and Methods: A retrospective data set of 35 patients with left-sided breast cancer with planning computed tomography scans under three breathing conditions (free breathing (FB), CPAP with 10 cmH2O pressure, and DIBH) was collected. Volumetric arc therapy plans aimed for 95% dose coverage to 95% of the planning target volume with a maximum dose below 107%. A comparative dosimetric analysis among the three plans was conducted. Additionally, geometric differences were assessed by calculating the minimum distance between the heart and the clinical target volume (CTV) in each planning computed tomography. Results: CPAP and DIBH plans demonstrated comparable mean heart doses (1.05 Gy), which were significantly lower than the FB plan (1.34 Gy). The maximum dose to the left anterior descending artery was smallest in the CPAP plan (4.44 Gy), followed by DIBH (4.73 Gy) and FB (7.33 Gy) plans. Other organ-at-risk doses for CPAP and DIBH were similar, with mean contralateral breast doses of 2.27 and 2.21 Gy, mean ipsilateral lung doses of 4.09 and 4.08 Gy, V20 at 6.11% and 6.31%, and mean contralateral lung doses of 0.94 and 0.92 Gy, respectively. No significant difference was found in the minimum heart-to-CTV distance between CPAP and DIBH. DIBH exhibited the greatest lung volume (3908 cc), followed by CPAP (3509 cc), and FB(2703 cc). Conclusions: The comparison between CPAP and DIBH shows their similarity in both geometric and dosimetric aspects, providing strong evidence for CPAP's effectiveness and feasibility in RT. This suggests its potential as an alternative to DIBH for patients with left-sided breast cancer.

2.
Int J Radiat Oncol Biol Phys ; 117(3): 690-700, 2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37201757

RESUMO

PURPOSE: The aim of this work was to prospectively evaluate the toxicity and cosmetic outcomes of 5-fraction, stereotactic, accelerated partial breast irradiation (APBI). METHODS AND MATERIALS: This prospective observational cohort study enrolled women who underwent APBI for invasive carcinoma or carcinoma in situ of the breast. APBI was delivered using a CyberKnife M6 robotic radiosurgery system at 30 Gy in 5 nonconsecutive, once-daily fractions. Women undergoing whole breast irradiation (WBI) were also enrolled for comparison. Patient-reported and physician-assessed adverse events were recorded. Breast fibrosis was measured using a tissue compliance meter, and breast cosmesis was assessed using BCCT.core (an automatic, computer-based software). Outcomes were collected until 24 months posttreatment according to the study protocol. RESULTS: In total, 204 patients (APBI, n = 103; WBI, n = 101) were enrolled. Regarding patient-reported outcomes, the APBI group reported significantly less skin dryness (6.9% vs 18.3%; P = .015), radiation skin reaction (9.9% vs 23.5%; P = .010), and breast hardness (8.0% vs 20.4%; P = .011) at 6 months than the WBI group. On physician assessment, the APBI group had significantly less dermatitis at 12 months (1.0% vs 7.2%; P = .027) than the WBI group. Any severe toxicities after APBI were rare in patient-reported outcomes (score ≥3, 3.0%) and physician assessments (grade ≥3, 2.0%). In the uninvolved quadrants, measured fibrosis in the APBI group was significantly lower than that in the WBI group at 6 (P = .001) and 12 (P = .029) months but not at 24 months. In the involved quadrant, measured fibrosis in the APBI group was not significantly different from that in the WBI group at any time. Cosmetic outcomes in the APBI group were mostly excellent or good (77.6%) at 24 months, and there was no significant cosmetic detriment from the baseline. CONCLUSIONS: Stereotactic APBI was associated with less fibrosis in the uninvolved breast quadrants than WBI. Patients showed minimal toxicity and no detrimental effects on cosmesis after APBI.


Assuntos
Neoplasias da Mama , Carcinoma in Situ , Feminino , Humanos , Neoplasias da Mama/radioterapia , Neoplasias da Mama/cirurgia , Neoplasias da Mama/patologia , Estudos Prospectivos , Mama/efeitos da radiação , Carcinoma in Situ/cirurgia , Fibrose , Resultado do Tratamento , Mastectomia Segmentar
3.
Phys Med ; 103: 119-126, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36279657

RESUMO

PURPOSE: To investigate the feasibility of using dental putty to fabricate custom molds for high-dose-rate (HDR) brachytherapy of oral mucosal melanoma. Practical guidelines of using dental putty for the custom mold fabrication are presented. METHODS: Dose measurements were performed using radiochromic films to understand the dosimetric characteristics of dental putty. The percentage depth dose (PDD) and profile curves were obtained using a single Co-60 source located on top of a cubic volume of the dental putty. Two custom molds were fabricated for a patient with mucosal melanoma lesions, which were spread throughout the right mandibular gingiva and soft palate regions. Furthermore, pretreatment dosimetry for both lesions was performed to evaluate the delivery quality of the resulting HDR brachytherapy plans and adjust the overall dose level. RESULTS: Prescribed doses for the two oral cavity regions were successfully delivered with a reasonable dose uniformity. Based on the measured single-source PDD curve, the maximum dose was observed at a depth of approximately 1 mm, which indicated steep dose gradients at depths ranging from 0 to 2 mm. Furthermore, a simulation with the measured single-source two-dimensional profile revealed that a source-to-source distance of 10 mm was appropriate to generate a uniform dose distribution at a source-to-surface distance of 5 mm. CONCLUSIONS: The use of a custom mold was found to be feasible for HDR brachytherapy while carefully considering the source-to-surface and source-to-source distances. Pretreatment delivery verification would be necessary when a uniform dose distribution is required.


Assuntos
Braquiterapia , Melanoma , Humanos , Braquiterapia/métodos , Dosagem Radioterapêutica , Estudos de Viabilidade , Radiometria/métodos , Melanoma/radioterapia
4.
Pract Radiat Oncol ; 12(5): e368-e375, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35151923

RESUMO

PURPOSE: Our purpose was to investigate the interfraction and intrafraction reproducibility and practical applicability of continuous positive airway pressure (CPAP) for left breast volumetric modulated arc therapy (VMAT). METHODS AND MATERIALS: Interfraction reproducibility of the position of the heart was evaluated by measuring the heart-to-target distance on 20 planning computed tomography (CT) and 300 daily cone beam CT of 20 patients with left breast cancer treated with a 15-fraction VMAT. The dosimetric metrics of the whole heart and its substructures were compared between CPAP and free-breathing based VMAT plans. Intrafraction reproducibility was evaluated by measuring the motions of the breast target and diaphragm in 4-dimensional CT of 20 female patients with nonbreast cancer. Lastly, we analyzed the CPAP compliance data of 237 consecutive patients with left-sided breast cancer with and without internal mammary node irradiation (IMNI). RESULTS: The heart position was reproducible as evidenced by an absolute average heart-to-target distance error of 2.0 ± 2.0 mm. Compared with free-breathing, CPAP significantly reduced the mean heart dose and the dose to the left ventricle and left anterior descending artery. The average intrafraction position variation of the breast target was 0.5 ± 0.5, 2.5 ± 2.0, and 1.8 ± 1.4 mm in the mediolateral, craniocaudal, and anteroposterior directions, respectively. CPAP was successfully applied in 221 patients (93%), with a mean heart dose of 1.6 ± 0.7 Gy (IMNI: 2.0 Gy and no IMNI: 1.1 Gy). CONCLUSIONS: CPAP has adequate heart-sparing capability and sufficient reproducibility in VMAT for left-sided breast cancer treatment, with a high compliance rate. Thus, CPAP is applicable in routine practice for left-sided breast cancer radiation therapy.


Assuntos
Neoplasias da Mama , Radioterapia de Intensidade Modulada , Neoplasias Unilaterais da Mama , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/etiologia , Neoplasias da Mama/radioterapia , Pressão Positiva Contínua nas Vias Aéreas , Feminino , Tomografia Computadorizada Quadridimensional , Humanos , Órgãos em Risco/efeitos da radiação , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Reprodutibilidade dos Testes , Neoplasias Unilaterais da Mama/diagnóstico por imagem , Neoplasias Unilaterais da Mama/radioterapia
5.
Technol Cancer Res Treat ; 21: 15330338221078464, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35167403

RESUMO

Purpose: Various deformable image registration (DIR) methods have been used to evaluate organ deformations in 4-dimensional computed tomography (4D CT) images scanned during the respiratory motions of a patient. This study assesses the performance of 10 DIR algorithms using 4D CT images of 5 patients with fiducial markers (FMs) implanted during the postoperative radiosurgery of multiple lung metastases. Methods: To evaluate DIR algorithms, 4D CT images of 5 patients were used, and ground-truths of FMs and tumors were generated by physicians based on their medical expertise. The positions of FMs and tumors in each 4D CT phase image were determined using 10 DIR algorithms, and the deformed results were compared with ground-truth data. Results: The target registration errors (TREs) between the FM positions estimated by optical flow algorithms and the ground-truth ranged from 1.82 ± 1.05 to 1.98 ± 1.17 mm, which is within the uncertainty of the ground-truth position. Two algorithm groups, namely, optical flow and demons, were used to estimate tumor positions with TREs ranging from 1.29 ± 1.21 to 1.78 ± 1.75 mm. With respect to the deformed position for tumors, for the 2 DIR algorithm groups, the maximum differences of the deformed positions for gross tumor volume tracking were approximately 4.55 to 7.55 times higher than the mean differences. Errors caused by the aforementioned difference in the Hounsfield unit values were also observed. Conclusions: We quantitatively evaluated 10 DIR algorithms using 4D CT images of 5 patients and compared the results with ground-truth data. The optical flow algorithms showed reasonable FM-tracking results in patient 4D CT images. The iterative optical flow method delivered the best performance in this study. With respect to the tumor volume, the optical flow and demons algorithms delivered the best performance.


Assuntos
Neoplasias Pulmonares , Radiocirurgia , Algoritmos , Marcadores Fiduciais , Tomografia Computadorizada Quadridimensional/métodos , Humanos , Processamento de Imagem Assistida por Computador/métodos , Neoplasias Pulmonares/diagnóstico por imagem
6.
Front Oncol ; 11: 753246, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34692536

RESUMO

PURPOSE: To develop an internal target volume (ITV) margin determination framework (or decision-supporting framework) for treating multiple lung metastases using CyberKnife Synchrony with intraoperatively implanted fiducial markers (IIFMs). The feasibility of using non-ideally implanted fiducial markers (a limited number and/or far from a target) for tracking-based lung stereotactic ablative radiotherapy (SABR) was investigated. METHODS: In the developed margin determination framework, an optimal set of IIFMs was determined to minimize a tracking uncertainty-specific ITV (ITVtracking) margin (margin required to cover target-to-marker motion discrepancy), i.e., minimize the motion discrepancies between gross tumor volume (GTV) and the selected set of fiducial markers (FMs). The developed margin determination framework was evaluated in 17 patients with lung metastases. To automatically calculate the respiratory motions of the FMs, a template matching-based FM tracking algorithm was developed, and GTV motion was manually measured. Furthermore, during-treatment motions of the selected FMs were analyzed using log files and compared with those calculated using 4D CTs. RESULTS: For 41 of 42 lesions in 17 patients (97.6%), an optimal set of the IIFMs was successfully determined, requiring an ITVtracking margin less than 5 mm. The template matching-based FM tracking algorithm calculated the FM motions with a sub-millimeter accuracy compared with the manual measurements. The patient respiratory motions during treatment were, on average, significantly smaller than those measured at simulation for the patient cohort considered. CONCLUSION: Use of the developed margin determination framework employing CyberKnife Synchrony with a limited number of IIFMs is feasible for lung SABR.

7.
Front Oncol ; 11: 645328, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33912459

RESUMO

PURPOSE: How modern cardiac sparing techniques and beam delivery systems using advanced x-ray and proton beam therapy (PBT) can reduce incidental radiation exposure doses to cardiac and pulmonary organs individually or in any combination is poorly investigated. METHODS: Among 15 patients with left-sided breast cancer, partial wide tangential 3D-conformal radiotherapy (3DCRT) delivered in conventional fractionation (CF) or hypofractionated (HF) schedules; PBT delivered in a CF schedule; and volumetric modulated arc therapy (VMAT) delivered in an HF schedule, each under continuous positive airway pressure (CPAP) and free-breathing (FB) conditions, were examined. Target volume coverage and doses to organs-at-risk (OARs) were calculated for each technique. Outcomes were compared with one-way analysis of variance and the Bonferroni test, with p-values <0.05 considered significant. RESULTS: Target volume coverage was within acceptable levels in all interventions, except for the internal mammary lymph node D95 (99% in PBT, 90% in VMAT-CPAP, 84% in VMAT-FB, and 74% in 3DCRT). The mean heart dose (MHD) was the lowest in PBT (<1 Gy) and VMAT-CPAP (2.2 Gy) and the highest in 3DCRT with CF/FB (7.8 Gy), respectively. The mean lung dose (MLD) was the highest in 3DCRT-CF-FB (20 Gy) and the lowest in both VMAT-HF-CPAP and PBT (approximately 5-6 Gy). VMAT-HF-CPAP and PBT delivered a comparable maximum dose to the left ascending artery (7.2 and 6.13 Gy, respectively). CONCLUSIONS: Both proton and VMAT in combination with CPAP can minimize the radiation exposure to heart and lung with optimal target coverage in regional RT for left-sided breast cancer. The clinical relevance of these differences is yet to be elucidated. Continued efforts are needed to minimize radiation exposures during RT treatment to maximize its therapeutic index.

8.
Front Oncol ; 10: 578921, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33194701

RESUMO

Purpose: The European Society of Radiation & Oncology and Advisory Committee on Radiation Oncology Practice (ESTRO-ACROP) presented new guidelines for clinical target volume (CTV) delineation in post-mastectomy radiation therapy (PMRT) after implant-based immediate breast reconstruction (IBR-i). This study evaluated the dosimetric characteristics, dosimetric accuracy, and delivery accuracy of these guidelines in volumetric modulated arc therapy (VMAT). Methods and Materials: This retrospective study included 15 patients with left breast cancer who underwent mastectomy with tissue expander placement followed by PMRT. An experienced radiation oncologist delineated the CTV twice on the same image datasets based on the ESTRO-ACROP (EA-TVD) and conventional target volume delineation (C-TVD) guidelines. All VMAT plans, which used a double partial arc, were generated using six MV photons. Clinically relevant dose-volume parameters for organs at risk were compared. Dosimetric accuracy of the treatment plans and delivery accuracy were assessed. Results: Target volume of EA-TVD was significantly smaller than that of C-TVD. Although no statistically significant difference was noted in the target coverage between the two VMAT plans, EA-TVD VMAT significantly reduced the mean heart dose (3.99 ± 1.02 vs. 5.84 ± 1.78 Gy, p = 0.000), the maximum left anterior descending coronary artery (LAD) dose (9.43 ± 3.04 vs. 13.97 ± 6.04 Gy, p = 0.026), and the mean LAD dose (4.52 ± 1.31 vs. 6.35 ± 2.79 Gy, p = 0.028) compared with C-TVD VMAT. No significant difference was observed with respect to the total monitor units, plan complexity, and delivery quality assurance. Conclusions: This is the first study to show significant dose reduction for the normal heart and LAD tissue offered by the EA-TVD, while maintaining dosimetric and delivery accuracy, in PMRT after IBR-i in VMAT for left-sided breast cancer patients.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA