Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Abdom Imaging ; 40(3): 595-600, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25214068

RESUMO

The purpose of this study was to prospectively compare the efficacy and controllability of pushable coil and detachable coil during embolization of gastroduodenal artery (GDA) while performing percutaneous implantation of port-catheter system for hepatic artery infusion chemotherapy. Fifty patients (M:F = 42:8, age: 31-81 years) with advanced hepatocellular carcinoma undergoing port-catheter system implantation were randomized into pushable coil group and detachable coil group. During catheter fixation, GDA was embolized as close to the origin as possible. Success rate, number of coils used, number of coils removed due to malposition after deployment, time to occlusion, uncoiled GDA length, pushability, and complications were compared. Pushability was graded as no tension, slight tension, and difficult to advance. Embolization was successful in 49 patients. One failure resulted from repeated regurgitation of pushable coil into hepatic artery. Number of coils used and removed coils, time to occlusion, and uncoiled GDA length were 1-3 (mean 2.32), 5 coils in 3 patients, 4-20 min (mean 8.00), and 0-15.0 mm (mean 3.36) in pushable coil group, and 1-5 (mean 2.12), 2 coils in 2 patients, 2-15 min (mean 7.40), and 0-10.2 mm (mean 2.92) in detachable coil group, respectively, without significant difference. Pushability was no tension (n = 24) and slight tension (n = 1) in pushable coil group and no tension (n = 16), slight tension (n = 7), and difficult to advance (n = 2) in detachable coil group. One hepatic artery dissection occurred in the failed case during coil removal. Pushable coils and detachable coils had similar efficacy and controllability during GDA embolization, although there was a trend favoring detachable coil.


Assuntos
Antineoplásicos/administração & dosagem , Carcinoma Hepatocelular/tratamento farmacológico , Embolização Terapêutica/instrumentação , Infusões Intra-Arteriais/métodos , Neoplasias Hepáticas/tratamento farmacológico , Radiografia Intervencionista/métodos , Desenho de Equipamento , Humanos , Estudos Prospectivos
2.
Adv Mater ; 28(22): 4563, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27273442

RESUMO

The design of an ultrathin, conformal electronic device that integrates electrotactile stimulation with electromyography, temperature, and strain sensing in a single, simple platform is reported by J. A. Rogers and co-workers on page 4462. Demonstrated application possibilities include prosthetic control with sensory feedback, monitors, and stimulation signals related to lower back exertion, and electrical muscle stimulation with feedback control.


Assuntos
Esforço Físico , Estimulação Elétrica , Eletromiografia , Retroalimentação Sensorial , Músculo Esquelético
3.
Adv Mater ; 28(22): 4462-71, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-26469201

RESUMO

The design of an ultrathin, conformal electronic device that integrates electrotactile stimulation with electromyography, temperature, and strain sensing in a single, simple platform is reported. Experiments demonstrate simultaneous use of multiple modes of operation of this type of device in the sensorimotor control of robotic systems, in the monitoring of lower back exertion and in muscle stimulation.


Assuntos
Eletromiografia/instrumentação , Esforço Físico , Epiderme , Humanos , Músculo Esquelético