1.
Acta Oncol ; 60(11): 1419-1424, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34596486

RESUMO

BACKGROUND: Small megavoltage photon fields are increasingly used in modern radiotherapy techniques such as stereotactic radiotherapy. Therefore, it is important to study the reliability of dosimetry in the small-field conditions. The IBA Razor Nano Chamber (Nano chamber) ionization chamber is particularly intended for small-field measurements. In this work, properties of the Nano chamber were studied with both measurements and Monte Carlo (MC) simulations. MATERIAL AND METHODS: The measurements and MC simulations were performed with 6 MV, 6 MV FFF and 10 MV FFF photon beams from the Varian TrueBeam linear accelerator. The source-to-surface distance was fixed at 100 cm. The measurements and MC simulations included profiles, percentage depth doses (PDD), and output factors (OF) in square jaw-collimated fields. The MC simulations were performed with the EGSnrc software system in a large water phantom. RESULTS: The measured profiles and PDDs obtained with the Nano chamber were compared against IBA Razor Diode, PTW microDiamond and the PTW Semiflex ionization chamber. These results indicate that the Nano chamber is a high-resolution detector and thus suitable for small field profile measurements down to field sizes 2 × 2 cm2 and appropriate for the PDD measurements. The field output correction factors kQclin, Qmsrfclin, fmsr and field OFs ΩQclin, Qmsrfclin, fmsr were determined according to TRS-483 protocol In the 6 MV FF and FFF beams, the determined correction factors kQclin, Qmsrfclin, fmsr were within 1.2% for the field sizes of 1 × 1 cm2-3 × 3 cm2 and the experimental and MC defined field output factors ΩQclin,Qmsrfclin,fmsr showed good agreement. CONCLUSION: The Nano chamber with its small cavity volume is a potential detector for the small-field dosimetry. In this study, the properties of this detector were characterized with measurements and MC simulations. The determined correction factors kQclin, Qmsrfclin, fmsr are novel results for the NC in the TrueBeam fields.


Assuntos
Aceleradores de Partículas , Radiometria , Humanos , Método de Monte Carlo , Fótons , Reprodutibilidade dos Testes
3.
Biomed Phys Eng Express ; 7(3)2021 05 07.
Artigo em Inglês | MEDLINE | ID: mdl-33836522

RESUMO

In small-field radiotherapy (RT), a significant challenge is to define the amount of radiation dose absorbed in the patient where the quality of the beam has to be measured with high accuracy. The properties of a proposed new beam quality specifier, namely the dose-area-product ratio at 20 and 10 cm depths in water or DAPR20,10, were studied to yield more information on its feasibility over the conventional quality specifier tissue-phantom ratio or TPR20,10. The DAPR20,10may be measured with a large-area ionization chamber (LAC) instead of small volume chambers or semi-conductors where detector, beam and water phantom positioning and beam perturbations introduce uncertainties. The effects of beam shape, size and energy on the DAPR20,10were studied and it was shown that the DAPR20,10increases with increasing beam energy similarly to TPR20,10but in contrast exhibits a small beam size and shape dependence. The beam profile outside the beam limiting devices has been shown to have a large contribution to the DAPR20,10. There is potential in large area chambers to be used in DAPR measurement and its use in dosimetry of small-beam RT for beam quality measurements.


Assuntos
Fótons , Radiometria , Humanos , Método de Monte Carlo , Imagens de Fantasmas , Água
4.
Phys Med Biol ; 62(12): 4870-4883, 2017 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-28327474

RESUMO

In small-beam radiation therapy (RT) the measurement of the beam quality parameter, i.e. the tissue-phantom ratio or TPR20,10, using a conventional point detector is a challenge. To obtain reliable results, one has to consider potential sources of error, including volume averaging and adjustment of the point detector into the narrow beam. To overcome these challenges, a different type of beam quality parameter in small beams was studied, namely the dose-area product ratio, or DAPR20,10. With this method, the measurement of a dose-area product (DAP) using a large-area plane-parallel chamber (LAC) eliminates the uncertainties in detector positioning and volume averaging that are present when using a point detector. In this study, the properties of the DAPR20,10 of a cone-collimated 6 MV photon beam were investigated using Monte Carlo (MC) calculations and the obtained values were compared to measurements obtained using two LAC detectors, PTW Type 34073 and PTW Type 34070. In addition, the possibility of determining the DAP using EBT3 film and a Razor diode detector was studied. The determination of the DAPR20,10 value was found to be feasible in external small-beam radiotherapy using cone-collimated beams with diameters from 4-40 mm, based on the results of the two LACs, the MC calculations and the Razor diode. The measurements indicated a constant DAPR20,10 value for fields 20-40 mm in diameter, with a maximum relative change of 0.6%, but an increase of 7.0% for fields from 20-4 mm in diameter for the PTW Type 34070 chamber. Simulations and measurements showed an increase of DAPR20,10 with increasing LAC size or dose integral area for the studied 4-40 mm cone-collimated 6 MV photon beams. This has the consequence that there should be a reference to the size of the used LAC active area or the DAP integration area with the reported DAPR20,10 value.


Assuntos
Método de Monte Carlo , Doses de Radiação , Radioterapia/métodos , Imagens de Fantasmas , Fótons/uso terapêutico , Dosagem Radioterapêutica , Incerteza