Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Skin Res Technol ; 26(4): 537-541, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31883147

RESUMO

BACKGROUND: Brachytherapy of thin skin tumors using beta particles can protect underlying sensitive structures such as the bone because of the rapid dose falloff of this type of radiation in tissue. The current work describes a skin brachytherapy applicator, based on beta radiation, that can provide the needed cell-killing radiation dose matched to the shape of individual skin tumors. MATERIALS AND METHODS: The applicator and its template were fabricated using 3D printing technology. Any clinically approved beta-emitting isotope in the form of a radioactive gel could theoretically be used in this applicator. Monte Carlo simulations were employed to study the capability of the applicator in conforming dose distribution based on the shape of the tumor. Dose profile in the shallow depth, transverse dose profiles at different depths, and the percent depth dose from this applicator were calculated. The radioisotope of choice for our calculations was Yttrium-90 (Y-90). RESULTS: Using the proposed applicator, it is possible to create a desired dose profile matching the tumor surface shape. CONCLUSION: The short-range of the beta radiation, together with the dose conforming capability of the applicator, may lead to minimal interactions with the healthy tissue around the skin lesion.


Assuntos
Braquiterapia , Neoplasias Cutâneas , Partículas beta , Braquiterapia/instrumentação , Braquiterapia/métodos , Simulação por Computador , Humanos , Método de Monte Carlo , Impressão Tridimensional , Radiometria , Dosagem Radioterapêutica , Neoplasias Cutâneas/radioterapia , Radioisótopos de Ítrio
2.
Skin Res Technol ; 26(1): 25-29, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31338896

RESUMO

BACKGROUND: Radiation therapy using beta particles is an interesting treatment for very superficial skin lesions. Due to their low penetration in tissue and rapid dose fall-off, beta particles can protect underlying bony structures and surrounding healthy tissue while irradiating the skin tumor. In the current work, a simple method for the fabrication of a radioactive patch for use in skin cancer therapy based on a beta-emitting isotope is presented. MATERIALS AND METHODS: The beta radiation sources were Y-90 microspheres currently used for catheter-based radioembolization of unresectable liver tumors. The microspheres were filtered through a syringe filter to trap them on the cellulose nitrate paper of the filter and create a radioactive patch. In the current study, to avoid the need for a hot laboratory, the experiment was done using nonradioactive microspheres. An optical microscope was used to verify the distribution of the particles on the filter paper. RESULTS: Visual evaluation of the patches showed that using the proposed method, therapeutic skin patches with a fairly uniform distribution of microspheres can be created. CONCLUSION: The proposed simple method may be used in creating radiotherapeutic patches using Y-90 microspheres for radiation therapy of thin skin lesions located close to sensitive structures.


Assuntos
Partículas beta/uso terapêutico , Microesferas , Neoplasias Cutâneas/radioterapia , Radioisótopos de Ítrio , Sistemas de Liberação de Medicamentos , Estudos de Viabilidade , Humanos , Radioisótopos de Ítrio/administração & dosagem , Radioisótopos de Ítrio/uso terapêutico
3.
J Appl Clin Med Phys ; 17(1): 374-386, 2016 01 08.
Artigo em Inglês | MEDLINE | ID: mdl-26894357

RESUMO

The main purpose of this study was to investigate patient dose in the chest (PA/AP/LAT) and skull (PA/AP/LAT) X-ray examinations, as frequent procedures. The study was performed in eight public hospitals of Khuzestan province, Iran. Patient dosimetry was conducted on 567 standard patient X-ray examinations (males: 61.2%, female: 38.2%). Dosimetry protocol in this study was indirect method, according to the International Atomic Energy Agency (IAEA) Technical Reports series No.457. Patients weighing 70 ± 10 kg were considered as standard. In the indirect dosimetry approach, exposure parameters such as kVp, mAs, focal film distance (FFD), and tube outputs recorded during data acquisition were used for calculating incident air kerma on the patient's skin, entrance surface air kerma (ESAK) that is recommended by the IAEA as the most appropriate patient dosimetry quantity in simple radiographic examinations. This survey reveals significant variations in the radiological practice. Results showed that the parameters set by radiologic technologists change in a wide range: mAs varied from 2 to 80 for skull PA, 2 to 202 for chest LAT, and FFD varied from 50 to 180 for skull LAT projection. The study showed that patient doses in three chest projections exceed the IAEA and European Commission dose reference levels (EC DRLs) - 1.0, 1.12, and 2.20 mGy for chest PA, chest AP, and chest LAT, respectively. Results also showed that mean ESAKs of patients in skull projections were generally lower than the IAEA and EC DRLs, 1.5, 1.72, and 2.25 for skull LAT, skull AP, and skull PA, respectively. This study provides evidence that dose reduction in the simple X-ray examinations is feasible by updating clinical audits and implementation of systematic quality assurance (QA) and quality control (QC) programs. The authors recommend that DRLs obtained in this study can be used as local DRLs in Khuzestan area and dose surveys must be performed in all provinces to establish national dose reference levels (NDRLs) in Iran.


Assuntos
Controle de Qualidade , Proteção Radiológica/normas , Radiografia Torácica/normas , Crânio/diagnóstico por imagem , Feminino , Humanos , Irã (Geográfico) , Doses de Radiação , Raios X
4.
Pharm Dev Technol ; 20(7): 845-853, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24980221

RESUMO

The aim of this study was to find a model using artificial neural networks (ANNs) to predict PLGA-PMBH nanoparticles (NPs) size in preparation by modified nanoprecipitation. The input variables were polymer content, drug content, power of sonication and ratio of organic/aqueous phase (i.e. acetone/water), while the NPs size of PLGA-PMBH was assumed as the output variable. Forty samples of PLGA-PMBH NPs containing anticancer drug (i.e. paclitaxel) were synthesized by changing the variable factors in the experiments. The data modeling were performed using ANNs. The effects of input variables (namely, polymer content, drug content, power of sonication and ratio of acetone/water) on the output variables were evaluated using the 3D graphs obtained after modeling. Contrasting the 3D graphs from the generated model revealed that the amount of polymer (PLGA-PMBH) and drug content (PTX) have direct relation with the size of polymeric NPs in the process. In addition, it was illustrated that the ratio of acetone/water was the most important factor affecting the particle size of PLGA-PMBH NPs provided by solvent evaporation technique. Also, it was found that increasing the sonication power (up to a certain amount) indirectly affects the polymeric NPs size however it was directly affected in higher values.

5.
AAPS PharmSciTech ; 16(5): 1059-68, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25652731

RESUMO

In this study, nanosuspension of stable iodine ((127)I) was prepared by nanoprecipitation process in microfluidic devices. Then, size of particles was optimized using artificial neural networks (ANNs) modeling. The size of prepared particles was evaluated by dynamic light scattering. The response surfaces obtained from ANNs model illustrated the determining effect of input variables (solvent and antisolvent flow rate, surfactant concentration, and solvent temperature) on the output variable (nanoparticle size). Comparing the 3D graphs revealed that solvent and antisolvent flow rate had reverse relation with size of nanoparticles. Also, those graphs indicated that the solvent temperature at low values had an indirect relation with size of stable iodine ((127)I) nanoparticles, while at the high values, a direct relation was observed. In addition, it was found that the effect of surfactant concentration on particle size in the nanosuspension of stable iodine ((127)I) was depended on the solvent temperature. Nanoprecipitation process of stable iodine (127I) and optimization of particle size using ANNs modeling.


Assuntos
Isótopos de Iodo/química , Técnicas Analíticas Microfluídicas , Modelos Químicos , Nanopartículas , Nanotecnologia/métodos , Redes Neurais de Computação , Tecnologia Farmacêutica/métodos , Precipitação Química , Difusão Dinâmica da Luz , Dispositivos Lab-On-A-Chip , Técnicas Analíticas Microfluídicas/instrumentação , Nanotecnologia/instrumentação , Tamanho da Partícula , Solventes/química , Tensoativos/química , Tecnologia Farmacêutica/instrumentação , Temperatura
6.
Appl Radiat Isot ; 204: 111117, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38007882

RESUMO

Brachytherapy of superficial skin tumors using beta-emitting sources is a method that has been investigated by some researchers in both simulation and experimental studies with promising results. In the current study, the effect of geometrical parameters of some relevant radionuclides including Y-90, Re-188, P-32, and Ho-166 on the depth dose distribution in skin tissue has been investigated through Monte Carlo simulation. MCNPX Monte Carlo code was employed to model the above-mentioned patch sources in cylindrical format and then the effect of patch geometrical parameters including the source-to-skin distance (SSD), patch thickness, and patch diameter on depth dose distribution was assessed through modeling and calculation of the dose inside a cubic phantom mimicking the skin tissue. The obtained results demonstrated that increasing the SSD, patch thickness, and patch diameter (with the same activity) will reduce the depth dose distribution. Changing the SSD has a more significant effect on the dose gradient within the depth than other geometrical parameters. It was also observed that the effect of patch diameter on the skin-delivered dose gets less sensible as the patch size goes beyond the range of beta radiation inside tissue. Finally, it can be concluded that the patch source geometrical parameters can affect the depth dose distribution inside the skin tissue. This fact may be of concern regarding the delivery of a high radiation dose in a single treatment session. Therefore, variations of patch source geometrical parameters should be considered during the skin dose calculation plan.


Assuntos
Braquiterapia , Rênio , Braquiterapia/métodos , Radioisótopos de Ítrio , Método de Monte Carlo , Dosagem Radioterapêutica , Radiometria/métodos
7.
Sci Rep ; 14(1): 5222, 2024 Mar 03.
Artigo em Inglês | MEDLINE | ID: mdl-38433243

RESUMO

In this research, we present a novel design protocol for the in-situ synthesis of MgAl layered double hydroxide-copper metal-organic frameworks (LDH-MOFs) nanocomposite based on the electrocoagulation process and chemical method. The overall goal in this project is the primary synthesis of para-phthalic acid (PTA) intercalated MgAl-LDH with Cu (II) ions to produce the paddle-wheel like Cu-(PTA) MOFs nanocrystals on/in the MgAl-LDH structure. The physicochemical properties of final product; Cu-(PTA) MOFs/MgAl-LDH, were characterized by the surface analysis and chemical identification methods (SEM, EDX, TEM, XRD, BET, FTIR, CHN, DLS, etc.). The Cu-(PTA) MOFs/MgAl-LDH nanocomposite was used to modification of the carbon paste electrode (CPE); Cu-(PTA) MOFs/MgAl-LDH/CPE. The electrochemical performance of Cu-(PTA) MOFs/MgAl-LDH/CPE was demonstrated through the utilization of electrochemical methods. The results show a stable redox behavior of the Cu (III)/Cu (II) at the surface of Cu-(PTA) MOFs/MgAl-LDH/CPE in alkaline medium (aqueous 0.1 M NaOH electrolyte). Then, the Cu-(PTA) MOFs/MgAl-LDH/CPE was used as a new electrocatalyst toward the oxidation of formaldehyde (FA). Electrochemical data show that the Cu-(PTA) MOFs/MgAl-LDH/CPE exhibits superior electrocatalytic performance on the oxidation of FA. Also the diffusion coefficient, exchange current density (J°) and mean value of catalytic rate constant (Kcat) were found to be 1.18 × 10-6 cm2 s-1, 23 mA cm-2 and 0.4537 × 104 cm3 mol-1 s-1, respectively. In general, it can be said the Cu-(PTA) MOFs/MgAl-LDHs is promising candidate for applications in direct formaldehyde fuel cells.

8.
Radiologie (Heidelb) ; 63(7): 530-538, 2023 Jul.
Artigo em Alemão | MEDLINE | ID: mdl-37347256

RESUMO

CLINICAL/METHODOLOGICAL ISSUE: Imaging of structures of internal organs often requires ionizing radiation, which is a health risk. Reducing the radiation dose can increase the image noise, which means that images provide less information. STANDARD RADIOLOGICAL METHODS: This problem is observed in commonly used medical imaging modalities such as computed tomography (CT), positron emission tomography (PET), single photon emission computed tomography (SPECT), angiography, fluoroscopy, and any modality that uses ionizing radiation for imaging. METHODOLOGICAL INNOVATIONS: Artificial intelligence (AI) can improve the quality of low-dose images and help minimize radiation exposure. Potential applications are explored, and frameworks and procedures are critically evaluated. PERFORMANCE: The performance of AI models varies. High-performance models could be used in clinical settings in the near future. Several challenges (e.g., quantitative accuracy, insufficient training data) must be addressed for optimal performance and widespread adoption of this technology in the field of medical imaging. PRACTICAL RECOMMENDATIONS: To fully realize the potential of AI and deep learning (DL) in medical imaging, research and development must be intensified. In particular, quality control of AI models must be ensured, and training and testing data must be uncorrelated and quality assured. With sufficient scientific validation and rigorous quality management, AI could contribute to the safe use of low-dose techniques in medical imaging.


Assuntos
Proteção Radiológica , Proteção Radiológica/métodos , Inteligência Artificial , Doses de Radiação , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tomografia por Emissão de Pósitrons
9.
RSC Adv ; 13(43): 29931-29943, 2023 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-37860173

RESUMO

In this work, a signal amplification strategy was designed by the fabrication of a highly sensitive and selective electrochemical sensor based on nickel-copper-zinc ferrite (Ni0.4Cu0.2Zn0.4Fe2O4)/carboxymethyl cellulose (CMC)/graphene oxide nanosheets (GONs) composite modified glassy carbon electrode (GCE) for determination of omeprazole (OMP). The one-step synthesized Ni0.4Cu0.2Zn0.4Fe2O4/CMC/GONs nanocomposite was characterized by scanning electron microscopy, energy-dispersive X-ray spectroscopy, transmission electron microscopy and X-ray diffraction techniques. Then, the Ni0.4Cu0.2Zn0.4Fe2O4/CMC/GONs/GCE was applied to study the electrochemical behavior of the OMP. Electrochemical data show that the Ni0.4Cu0.2Zn0.4Fe2O4/CMC/GONs/GCE exhibits superior electrocatalytic performance on the oxidation of OMP compared with bare GCE, GONs/GCE, CMC/GONs/GCE and MFe2O4/GCE (M = Cu, Ni and Zn including single, double and triple of metals) which can be attributed to the synergistic effects of the nanocomposite components, outstanding electrical properties of Ni0.4Cu0.2Zn0.4Fe2O4 and high conductivity of CMC/GONs as well as the further electron transport action of the nanocomposite. Under optimal conditions, the Ni0.4Cu0.2Zn0.4Fe2O4/CMC/GONs/GCE offers a high performance toward the electrodetermination of OMP with the wide linear-range responses (0.24-5 and 5-75 µM), lower detection limit (0.22 ± 0.05 µM), high sensitivity (1.1543 µA µM-1 cm-2), long-term signal stability and reproducibility (RSD = 2.54%). It should be noted that the Ni0.4Cu0.2Zn0.4Fe2O4/CMC/GONs/GCE sensor could also be used for determination of OMP in drug and biological samples, indicating its feasibility for real analysis.

10.
Int J Radiat Biol ; 97(9): 1289-1298, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34047663

RESUMO

INTRODUCTION: Nowadays, some nanoparticles (NPs) are known and used as radiosensitizers in radiotherapy and radiobiology, due to their desired biological, physical, and chemical effects on cells. This study aimed to evaluate and compare the dose enhancement factor (DEF) and the biological effectiveness of some common NPs through EGSnrc and MCDS Monte Carlo (MC) simulation codes. MATERIALS AND METHODS: To evaluate considered NPs' DEF, a single NP with 50 nm diameter was simulated at the center of concentric spheres. NP irradiations were done with 30, 60, and 100 keV photon energies. The secondary electron spectra were scored at the surface of considered NPs, and the dose values were scored at surrounding water-filled spherical shells which were distributed up to 4000 nm from the NP surface. The electron spectra were used in the MCDS code to obtain different initial DNA damages for the calculation of enhanced relative biological effectiveness (eRBE). RESULTS: By decreasing the photon energy, an increment of DEF was seen for all studied NPs. The maximum DEF at 30, 60, and 100 keV photon energies were respectively related to silver (Ag), gadolinium (Gd), and bismuth (Bi) NPs. The maximum double-strand break (DSB) related (eRBEDSB) values for the 30 keV photon belonged to Ag, while BiNPs showed the maximum values at other photon energies. The minimum eRBEDSB values were also related to iron (Fe) NPs at the entire range of studied photon energies. CONCLUSIONS: The compared nanoscale physical and biological results of our study can be helpful in the selection of optimum NP as a radiosensitizer in future radiobiological studies. Bi, gold (Au), Ag, and platinum (Pt) NPs had great potential, respectively, as radiosensitizers relative to the other studied NPs.


Assuntos
Método de Monte Carlo , Nanopartículas , Radiossensibilizantes/farmacologia , Eficiência Biológica Relativa , Relação Dose-Resposta à Radiação
11.
Biomed Tech (Berl) ; 65(1): 1-10, 2020 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-31348751

RESUMO

Radioguided surgery (RGS) is the use of radiation detection probes and handheld gamma cameras in surgery rooms to identify radioactively labeled lesions inside the body with an aim to improve surgical outcome. In today's surgery, application of these devices is a well-established practice, which provides surgeons with real-time information to guide them to the site of a lesion. In recent years, there have been several major improvements in the technology and design of gamma probes and handheld gamma cameras, enhancing their applications in surgical practices. Handheld gamma cameras, for example, are now moving from single-modality to dual-modality scanners that add anatomical data to the physiologic data, and with that provide more clinical information of the tissue under study. Also, in the last decade, a radioguided surgical technique based on the Cerenkov radiation was introduced, with more improved sensitivity in identifying radioactively labeled lesions. Additionally, recent advances in hybrid tracers have led to more efficient detection of lesions labeled with these tracers. Besides, it seems that combining medical robotics and augmented reality technology with current radioguided surgical practices potentially will change the delivery and performance of RGS in the near future. The current paper aims to give an overview of the physics of RGS and summarizes recent advances in this field that have a potential to improve the application of radioguided surgical procedures in the management of cancer.


Assuntos
Câmaras gama , Cirurgia Assistida por Computador/instrumentação , Humanos , Radiocirurgia , Cirurgia Assistida por Computador/métodos
12.
J Dermatolog Treat ; 30(8): 831-839, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30703334

RESUMO

Nonmelanoma skin cancer (NMSC) is a major health concern due to its high incidence rate, its negative impact on the quality of life of patients as well as the associated economic burden to the healthcare system. Surgery is currently the primary treatment offered for skin cancer patients but not applicable or available in all cases. Radiation therapy (RT), with its long successful history in the management of cancer, has shown to be an effective alternative or complementary method in cutaneous oncology. Specifically, for dermatology applications, RT is very often the preferred option due to its favorable cosmetic results, besides the excellent control rate of the tumor. During the last 120 years since the introduction of treatments based on ionizing radiation, several techniques in this area have been developed. Radionuclide brachytherapy, electronic brachytherapy, X-ray therapies with kilovolt (kV) to megavolt (MV) photons and electron beam therapy are the established methods that are currently used on skin cancer patients. The purpose of this article is to overview these techniques and discuss the pros and cons of these methods in dermatology practices. Additionally, a new approach of beta RT of superficial skin tumors is discussed, which may offer exciting features in the management of NMSC.


Assuntos
Radiação Ionizante , Neoplasias Cutâneas/radioterapia , Partículas beta/uso terapêutico , Braquiterapia/métodos , Humanos , Imageamento por Ressonância Magnética , Neoplasias Cutâneas/diagnóstico , Tomografia Computadorizada por Raios X
13.
Comput Biol Med ; 107: 10-17, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30769168

RESUMO

Artery perforation during a vascular catheterization procedure is a potentially life threatening event. It is of particular importance for the surgeons to be aware of hidden or non-obvious events. To minimize the impact it is crucial for the surgeon to detect such a perforation very early. We propose a novel approach to identify perforations based on the acquisition and analysis of audio signals on the outside proximal end of a guide wire. The signals were acquired using a stethoscope equipped with a microphone and attached to the proximal end of the guide wire via a 3D printed adapter. Bispectral analysis was employed to extract acoustic signatures in the signal and several features were extracted from the bispectrum of the signal. Finally, three machine learning algorithms - K-nearest Neighbor, Support Vector Machine (SVM), and Artificial Neural Network (ANN)- were used to classify a signal as a perforation or as an artifact. The bispectrum-based features resulted in valuable features allowing a perforation to be clearly identifiable from other occurring events. A perforation leaves a clear audio signal trace in the time-frequency domain. The recordings were classified as perforation, friction or guide wire bump using SVM with 97% (polykernel) and 98.62% (RBF) accuracy, k-nearest Neighbor an accuracy of 98.28% and ANN with accuracy of 98.73% was obtained. The presented approach shows that interactions starting at the tip of a guide wire can be picked up at its proximal end providing a valuable additional information that could be used during a guide wire procedure.


Assuntos
Cateterismo , Aprendizado de Máquina , Processamento de Sinais Assistido por Computador , Espectrografia do Som/métodos , Algoritmos , Animais , Cateterismo/instrumentação , Cateterismo/métodos , Vasos Coronários/cirurgia , Redes Neurais de Computação , Suínos
14.
Annu Int Conf IEEE Eng Med Biol Soc ; 2019: 6979-6982, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31947444

RESUMO

Surface brachytherapy is an effective method in the treatment of skin cancer. Current skin brachytherapy techniques are based on the placement of a source of gamma or X-ray photons in a close distance from the skin to irradiate the lesion. Due to the nature of photons, radiation dose in these methods may affect healthy tissue as well as sensitive structures around the target. In order to minimize unwarranted and incidental exposure, we propose a new skin brachytherapy applicator based upon beta particles which have penetration ranges of a few millimeters in tissue. The proposed concept is radioactive gel housed within a pre-designed tumor-specific applicator matching the topology of the skin lesion. The particles mixed with the gel showed a uniform distribution pattern, which is an essential prerequisite in having a uniform dose profile on the skin surface. Based on the dose calculation data from the proposed concept, the dose delivered to the depth of 4500 µm in skin tissue is 10% of the dose delivered to the surface of the tumor, making it suitable is treating thin skin tumors especially when located on top of the bone. Through the innovative combination of radioactive gel and tumor-specific applicator, the radiation entering the skin surface can be personalized while minimizing the adverse effects of undesired exposure to the surrounding healthy tissue.


Assuntos
Braquiterapia , Neoplasias Cutâneas , Humanos , Método de Monte Carlo , Impressão Tridimensional , Dosagem Radioterapêutica
15.
Sci Rep ; 8(1): 12070, 2018 08 13.
Artigo em Inglês | MEDLINE | ID: mdl-30104613

RESUMO

We propose a new and complementary approach to image guidance for monitoring medical interventional devices (MID) with human tissue interaction and surgery augmentation by acquiring acoustic emission data from the proximal end of the MID outside the patient to extract dynamical characteristics of the interaction between the distal tip and the tissue touched or penetrated by the MID. We conducted phantom based experiments (n = 955) to show dynamic tool/tissue interaction during tissue needle passage (a) and vessel perforation caused by guide wire artery perforation (b). We use time-varying auto-regressive (TV-AR) modelling to characterize the dynamic changes and time-varying maximal energy pole (TV-MEP) to compute subsequent analysis of MID/tissue interaction characterization patterns. Qualitative and quantitative analysis showed that the TV-AR spectrum and the TV-MEP indicated the time instants of the needle path through different phantom objects (a) and clearly showed a perforation versus other generated artefacts (b). We demonstrated that audio signals acquired from the proximal part of an MID could provide valuable additional information to surgeons during minimally invasive procedures.


Assuntos
Acústica/instrumentação , Complicações Intraoperatórias/prevenção & controle , Procedimentos Cirúrgicos Minimamente Invasivos/efeitos adversos , Agulhas/efeitos adversos , Artefatos , Biópsia/efeitos adversos , Biópsia/instrumentação , Catéteres/efeitos adversos , Humanos , Complicações Intraoperatórias/etiologia , Estetoscópios
16.
World J Nucl Med ; 16(2): 150-155, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28553183

RESUMO

The main purpose of this study was to investigate dose rate emanating from patients treated with 131I to evaluate which of the theoretical formulas, inverse-square law (ISL) and International Atomic Energy Agency-International Commission on Radiological Protection (IAEA-ICRP) suggested equation, can provide a sufficiently close approximation of the measured dose rate. Measurements were performed based on the IAEA safety report No. 63 method at 0, 12, 24, and 48 h after administration of radioiodine at a distance of 1 m for 69 patients and for the rest of 67 patients, dose rate was measured at 2, 4, 24, and 48 h at a distance of 2 m. Results revealed that the ISL formula gained better approximation of measured dose rates than the IAEA-ICRP equation with the lesser error. The ISL formula is still more reliable than the novel method of dose calculation in the vicinity of patients. This finding reminded us the prime importance of distance as a radiation protection principle.

17.
Phys Med ; 37: 32-36, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28535912

RESUMO

PURPOSE: The current study evaluated the effect of lens-induced high myopia (IHM) on the activity of the occipital visual cortex during two visual stimuli presentations to the subjects. This was done by measuring the Blood Oxygenation Level Dependent (BOLD) signal using functional MRI (fMRI). METHODS: BOLD contrast fMRI was performed with a 1.5T MRI scanner on 12 emmetropic subjects (refractive error <±0.25Diopter) with no history of neurologic disorder. IHM conditions were applied to subjects by three convex lenses of +5D, +7D and +10D. Visual stimuli with 0.34cpd and 1.84cpd spatial frequencies (SF) were presented as a block paradigm to the participants in three IHM states and normal vision state during fMRI data acquisition. Resultant fMRI data were compared among different refractive states. RESULTS: Data analysis showed that IHM did not cause a significant change in the visual cortex activity throughout the presentation of 0.34cpd SF visual stimulus and BOLD signal intensity remained approximately constant (p=0.17). Although, fMRI responses to visual stimuli with spatial frequency of 1.84cpd demonstrated that visual cortex activity was significantly reduced in IHM states compared to normal vision (p=0.01), the results showed no significant differences between three different values of IHM. CONCLUSIONS: This study shows severe blurring caused by lens induced high myopia can decrease BOLD signal intensity depending on the visual stimulus pattern details. However in the low and moderate range of spatial frequencies, blur increment from +5D up to +10D is not associated with further reduction in the BOLD signal of the occipital visual cortex.


Assuntos
Imageamento por Ressonância Magnética , Miopia/fisiopatologia , Córtex Visual/diagnóstico por imagem , Adulto , Feminino , Humanos , Masculino , Estimulação Luminosa , Adulto Jovem
18.
Australas Phys Eng Sci Med ; 40(2): 395-400, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28397060

RESUMO

In general, a weighting factor of one is applied for low linear energy transfer radiations. However, several studies indicate that relative biological effectiveness (RBE) of low energy photons and electrons is greater than one. The aim of this current study was calculating the RBE of I-131 radiation relative to Co-60 gamma photons in 100 µm spheroid cells using Monte Carlo (MC) simulations. These calculations were compared to experimentally measured results. MCNPX2.6 was used to simulate the I-131 and Co-60 irradiation setups and calculate the secondary electron spectra at energies higher than 1 keV with varying oxygen concentrations. The electron spectra at energies lower than 1 keV were obtained by extrapolation (down to 10 eV). The calculated electron spectra were input into the MCDS micro-dosimetric Monte Carlo code to calculate the DSB induction and related RBE. The calculated RBE of I-131 radiation relative to Co-60 photons, as the reference radiation recommended by the International Commission on Radiation Protection (ICRP), was 1.06, 1.03 and 1.02 for oxygen concentrations of 0, 5 and 100%, respectively. Results of MC simulations indicate the RBE of I-131 is greater than one. This finding, despite a 10% discrepancy with the findings of the previous in vitro study of one of the authors of this paper, reemphasizes that I-131 radiation induces more severe biological damage than current ICRP recommendations.


Assuntos
Biomarcadores/análise , Dano ao DNA , Radioisótopos do Iodo/química , Método de Monte Carlo , Eficiência Biológica Relativa , Partículas beta , Radioisótopos de Cobalto/química , Simulação por Computador , Raios gama
19.
J Clin Diagn Res ; 11(2): TC08-TC11, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28384957

RESUMO

INTRODUCTION: It is shown that beta-D-glucan is an immunologic system booster with radioprotectory effects. Radioprotectors are chemical components that can alleviate biological damage produced by ionizing radiation. AIM: This study was designed to investigate the synergistic radioprotectory effects of beta-D-glucan and vitamin E on irradiated mice with 60Co source. MATERIALS AND METHODS: A total of 240 female mice were arranged in four, equal population groups of control group (C), treated group with beta D-glucan (G), treated group with vitamin E (E), and treated group with both beta D-glucan and vitamin E (G+E). Each group was divided into three equal population groups of D6, D7 and D8 exposed to 60Co radiation with prescribed total body dose of 6, 7 and 8 Gray (Gy), respectively. After the exposure, the number of survived animals was counted by time, then Lethal Dose50/30 (LD50/30), Lethal Dose50/60 (LD50/60) and Dose Reduction Factor (DRF) were calculated in all groups and corresponding groups. RESULTS: Based on the results of current study, treatment of the animals with vitamin E did not change values of LD50/30 and LD50/60, in comparison to control group. LD50/30 and LD50/60 of treated groups with beta D-glucan and beta D-glucan + vitamin E showed significant difference with those of control group (p<0.01). The DRF values in groups E, G and G + E, were calculated respectively as 1, 1.25 and 1.375 based on LD50/30, and respectively as 1, 1.17 and 1.33 based on LD50/60. While values of DRF in groups G and G + E showed significant difference in comparison to that of control group (p<0.01), but the difference between DRF of groups G and G + E was not significant (p=0.395). CONCLUSION: The findings of study obviously showed that, presence of beta D-glucan in the body of mice, during exposure to ionizing radiation, leads to DRF of higher than one, proving the radioprotectory effect of this agent. Also, we demonstrated that, while vitamin E had no radioprotectory effect on irradiated mice, beta D-glucan in combination with vitamin E increased resistance of mice against ionizing radiation.

20.
Int J Comput Assist Radiol Surg ; 12(11): 1995-2002, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28488238

RESUMO

PURPOSE: Surgery, chemo- and/or external radiation therapy are the standard therapy options for the treatment of laryngeal cancer. Trans-oral access for the surgery reduces traumata and hospitalization time. A new trend in treatment is organ-preserving surgery. To avoid regrowth of cancer, this type of surgery can be combined with radiation therapy. Since external radiation includes healthy tissue surrounding the cancerous zone, a local and direct intraoral radiation delivery would be beneficial. METHODS: A general concept for a trans-oral radiation system was designed, based on clinical need identification with a medical user. A miniaturized X-ray tube was used as the radiation source for the intraoperative radiation delivery. To reduce dose distribution on healthy areas, the X-ray source was collimated by a newly designed adjustable shielding system as part of the housing. For direct optical visualization of the radiation zone, a miniature flexible endoscope was integrated into the system. The endoscopic light cone and the field of view were aligned with the zone of the collimated radiation. The intraoperative radiation system was mounted on a semi-automatic medical holder that was combined with a frontal actuator for rotational and translational movement using piezoelectric motors to provide precise placement. RESULTS: The entire technical set-up was tested in a simulated environment. The shielding of the X-ray source was verified by performing conventional detector-based dose measurements. The delivered dose was estimated by an ionization chamber. The adjustment of the radiation zone was performed by a manual controlling mechanism integrated into the hand piece of the device. An endoscopic fibre was also added to offer visualization and illumination of the radiation zone. The combination of the radiation system with the semi-automatic holder and actuator offered precise and stable positioning of the device in range of micrometres and will allow for future combination with a radiation planning system. CONCLUSIONS: The presented system was designed for radiation therapy of the oral cavity and the larynx. This first set-up tried to cover all clinical aspects that are necessary for a later use in surgery. The miniaturized X-ray tube offers the size and the power for intraoperative radiation therapy. The adjustable shielding system in combination with the holder and actuator provides a precise placement. The visualization of radiation zone allows a targeting and observation of the radiation zone.


Assuntos
Neoplasias Laríngeas/radioterapia , Laringoscopia/métodos , Procedimentos Cirúrgicos Otorrinolaringológicos , Terapia por Raios X/instrumentação , Desenho de Equipamento , Humanos , Miniaturização , Tratamentos com Preservação do Órgão , Doses de Radiação , Radioterapia/instrumentação , Radioterapia/métodos , Radioterapia Adjuvante , Terapia por Raios X/métodos , Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA