Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
Assunto da revista
Intervalo de ano de publicação
1.
J Neurosurg Spine ; 38(1): 115-125, 2023 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-36152329

RESUMO

OBJECTIVE: The purpose of this study was to evaluate the safety and efficacy of a posterior facet replacement device, the Total Posterior Spine (TOPS) System, for the treatment of one-level symptomatic lumbar stenosis with grade I degenerative spondylolisthesis. Posterior lumbar arthroplasty with facet replacement is a motion-preserving alternative to lumbar decompression and fusion. The authors report the preliminary results from the TOPS FDA investigational device exemption (IDE) trial. METHODS: The study was a prospective, randomized controlled FDA IDE trial comparing the investigational TOPS device with transforaminal lumbar interbody fusion (TLIF) and pedicle screw fixation. The minimum follow-up duration was 24 months. Validated patient-reported outcome measures included the Oswestry Disability Index (ODI) and visual analog scale (VAS) for back and leg pain. The primary outcome was a composite measure of clinical success: 1) no reoperations, 2) no device breakage, 3) ODI reduction of ≥ 15 points, and 4) no new or worsening neurological deficit. Patients were considered a clinical success only if they met all four measures. Radiographic assessments were made by an independent core laboratory. RESULTS: A total of 249 patients were evaluated (n = 170 in the TOPS group and n = 79 in the TLIF group). There were no statistically significant differences between implanted levels (L4-5: TOPS, 95% and TLIF, 95%) or blood loss. The overall composite measure for clinical success was statistically significantly higher in the TOPS group (85%) compared with the TLIF group (64%) (p = 0.0138). The percentage of patients reporting a minimum 15-point improvement in ODI showed a statistically significant difference (p = 0.037) favoring TOPS (93%) over TLIF (81%). There was no statistically significant difference between groups in the percentage of patients reporting a minimum 20-point improvement on VAS back pain (TOPS, 87%; TLIF, 64%) and leg pain (TOPS, 90%; TLIF, 88%) scores. The rate of surgical reintervention for facet replacement in the TOPS group (5.9%) was lower than the TLIF group (8.8%). The TOPS cohort demonstrated maintenance of flexion/extension range of motion from preoperatively (3.85°) to 24 months (3.86°). CONCLUSIONS: This study demonstrates that posterior lumbar decompression and dynamic stabilization with the TOPS device is safe and efficacious in the treatment of lumbar stenosis with degenerative spondylolisthesis. Additionally, decompression and dynamic stabilization with the TOPS device maintains segmental motion.


Assuntos
Parafusos Pediculares , Fusão Vertebral , Espondilolistese , Humanos , Espondilolistese/diagnóstico por imagem , Espondilolistese/cirurgia , Fusão Vertebral/métodos , Resultado do Tratamento , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Estudos Prospectivos , Constrição Patológica/cirurgia , Dor nas Costas/cirurgia , Artroplastia , Procedimentos Cirúrgicos Minimamente Invasivos , Estudos Retrospectivos
2.
Spine (Phila Pa 1976) ; 41(13): 1075-1083, 2016 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-26825787

RESUMO

STUDY DESIGN: A prospective, randomized, controlled, parallel, single-blinded noninferiority multicenter pivotal FDA IDE trial. OBJECTIVE: The objective of this study was to investigate efficacy and safety of i-Factor Bone Graft (i-Factor) compared with local autograft in single-level anterior cervical discectomy and fusion (ACDF) for cervical radiculopathy. SUMMARY OF BACKGROUND DATA: i-Factor is a composite bone substitute material consisting of the P-15 synthetic collagen fragment adsorbed onto anorganic bone mineral and suspended in an inert biocompatible hydrogel carrier. P-15 has demonstrated bone healing efficacy in dental, orthopedic, and nonhuman applications. METHODS: Patients randomly received either autograft (N = 154) or i-Factor (N = 165) in a cortical ring allograft. Study success was defined as noninferiority in fusion, Neck Disability Index (NDI), and Neurological Success endpoints, and similar adverse events profile at 12 months. RESULTS: At 12 months (follow-up rate 87%), both i-Factor and autograft subjects demonstrated a high fusion rate (88.97% and 85.82%, respectively, noninferiority P = 0.0004), significant improvements in NDI (28.75 and 27.40, respectively, noninferiority P < 0.0001), and high Neurological Success rate (93.71% and 93.01%, respectively, noninferiority P < 0.0001). There was no difference in the rate of adverse events (83.64% and 82.47% in the i-Factor and autograft groups, respectively, P = 0.8814). Overall success rate consisting of fusion, NDI, Neurological Success and Safety Success was higher in i-Factor subjects than in autograft subjects (68.75% and 56.94%, respectively, P = 0.0382). Improvements in VAS pain and SF-36v2 scores were clinically relevant and similar between the groups. A high proportion of patients reported good or excellent Odom outcomes (81.4% in both groups). CONCLUSION: i-Factor has met all four FDA mandated noninferiority success criteria and has demonstrated safety and efficacy in single-level ACDF for cervical radiculopathy. i-Factor and autograft groups demonstrated significant postsurgical improvement and high fusion rates. LEVEL OF EVIDENCE: 1.


Assuntos
Transplante Ósseo/normas , Vértebras Cervicais/cirurgia , Aprovação de Equipamentos , Discotomia/normas , Radiculopatia/cirurgia , Fusão Vertebral/normas , Adulto , Transplante Ósseo/métodos , Discotomia/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Radiculopatia/diagnóstico , Radiculopatia/epidemiologia , Método Simples-Cego , Fusão Vertebral/métodos , Transplante Autólogo/métodos , Transplante Autólogo/normas , Resultado do Tratamento , Estados Unidos/epidemiologia , United States Food and Drug Administration
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA