1.
Minim Invasive Ther Allied Technol ; 31(2): 297-305, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32729771

RESUMO

INTRODUCTION: This paper reports the system integration and cadaveric assessment of a body-mounted robotic system for MRI-guided lumbar spine injections. The system is developed to enable MR-guided interventions in closed bore magnet and avoid problems due to patient movement during cannula guidance. MATERIAL AND METHODS: The robot is comprised by a lightweight and compact structure so that it can be mounted directly onto the lower back of a patient using straps. Therefore, it can minimize the influence of patient movement by moving with the patient. The MR-Conditional robot is integrated with an image-guided surgical planning workstation. A dedicated clinical workflow is created for the robot-assisted procedure to improve the conventional freehand MRI-guided procedure. RESULTS: Cadaver studies were performed with both freehand and robot-assisted approaches to validate the feasibility of the clinical workflow and to assess the positioning accuracy of the robotic system. The experiment results demonstrate that the root mean square (RMS) error of the target position to be 2.57 ± 1.09 mm and of the insertion angle to be 2.17 ± 0.89°. CONCLUSION: The robot-assisted approach is able to provide more accurate and reproducible cannula placements than the freehand procedure, as well as to reduce the number of insertion attempts.


Assuntos
Procedimentos Cirúrgicos Robóticos , Robótica , Cadáver , Humanos , Injeções Espinhais , Imageamento por Ressonância Magnética
2.
IEEE ASME Trans Mechatron ; 26(1): 255-266, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33994771

RESUMO

This paper reports the development of a fully actuated robotic assistant for magnetic resonance imaging (MRI)-guided precision conformal ablation of brain tumors using an interstitial high intensity needle-based therapeutic ultrasound (NBTU) ablator probe. The robot is designed with an eight degree-of-freedom (DOF) remote center of motion (RCM) manipulator driven by piezoelectric actuators, five for aligning the ultrasound thermal ablator to the target lesions and three for inserting and orienting the ablator and its cannula to generate a desired ablation profile. The 8-DOF fully actuated robot can be operated in the scanner bore during imaging; thus, alleviating the need of moving the patient in or out of the scanner during the procedure, and therefore potentially reducing the procedure time and streamlining the workflow. The free space positioning accuracy of the system is evaluated with the OptiTrack motion capture system, demonstrating the root mean square (RMS) error of the tip position to be 1.11±0.43mm. The system targeting accuracy in MRI is assessed with phantom studies, indicating the RMS errors of the tip position to be 1.45±0.66mm and orientation to be 1.53±0.69°. The feasibility of the system to perform thermal ablation is validated through a preliminary ex-vivo tissue study with position error less than 4.3mm and orientation error less than 4.3°.

3.
Artigo em Inglês | MEDLINE | ID: mdl-34422445

RESUMO

This paper reports the development of a fully actuated body-mounted robotic assistant for MRI-guided low back pain injection. The robot is designed with a 4-DOF needle alignment module and a 2-DOF remotely actuated needle driver module. The 6-DOF fully actuated robot can operate inside the scanner bore during imaging; hence, minimizing the need of moving the patient in or out of the scanner during the procedure, and thus potentially reducing the procedure time and streamlining the workflow. The robot is built with a lightweight and compact structure that can be attached directly to the patient's lower back using straps; therefore, attenuating the effect of patient motion by moving with the patient. The novel remote actuation design of the needle driver module with beaded chain transmission can reduce the weight and profile on the patient, as well as minimize the imaging degradation caused by the actuation electronics. The free space positioning accuracy of the system was evaluated with an optical tracking system, demonstrating the mean absolute errors (MAE) of the tip position to be 0.99±0.46 mm and orientation to be 0.99±0.65°. Qualitative imaging quality evaluation was performed on a human volunteer, revealing minimal visible image degradation that should not affect the procedure. The mounting stability of the system was assessed on a human volunteer, indicating the 3D position variation of target movement with respect to the robot frame to be less than 0.7 mm.

4.
Int Symp Med Robot ; 20202020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34595484

RESUMO

Retinal vein cannulation (RVC) is a potential treatment for retinal vein occlusion (RVO). Manual surgery has limitations in RVC due to extremely small vessels and instruments involved, as well as the presence of physiological hand tremor. Robot-assisted retinal surgery may be a better approach to smooth and accurate instrument manipulation during this procedure. Motion of the retina and cornea related to heartbeat may be associated with unexpected forces between the tool and eyeball. In this paper, we propose a force-based control strategy to automatically compensate for the movement of the retina maintaining the tip force and sclera force in a predetermined small range. A dual force-sensing tool is used to monitor the tip force, sclera force and tool insertion depth, which will be used to derive a desired joint velocity for the robot via a modified admittance controller. Then the tool is manipulated to compensate for the movement of the retina as well as reduce the tip force and sclera force. Quantitative experiments are conducted to verify the efficacy of the control strategy and a user study is also conducted by a retinal surgeon to demonstrate the advantages of our automatic compensation approach.

5.
Rep U S ; 2020: 3105-3111, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34012703

RESUMO

Robot-assisted vitreoretinal surgery can filter surgeons' hand tremors and provide safe, accurate tool manipulation. In this paper, we report the design, optimization, and evaluation of a novel tilt mechanism for a new Steady-Hand Eye Robot (SHER). The new tilt mechanism features a four-bar linkage design and has a compact structure. Its kinematic configuration is optimized to minimize the required linear range of motion (LRM) for implementing a virtual remote center-of-motion (V-RCM) while tilting a surgical tool. Due to the different optimization constraints for the robots at the left and right sides of the human head, two configurations of this tilt mechanism are proposed. Experimental results show that the optimized tilt mechanism requires a significantly smaller LRM (e.g. 5.08 mm along Z direction and 8.77 mm along Y direction for left side robot) as compared to the slider-crank tilt mechanism used in the previous SHER (32.39 mm along Z direction and 21.10 mm along Y direction). The feasibility of the proposed tilt mechanism is verified in a mock bilateral robot-assisted vitreoretinal surgery. The ergonomically acceptable robot postures needed to access the surgical field is also determined.

6.
IEEE Trans Med Robot Bionics ; 2(4): 557-560, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33778433

RESUMO

This paper reports the development and initial cadaveric evaluation of a robotic framework for MRI-guided interventions using a body-mounted approach. The framework is developed based on modular design principles. The framework consists of a body-mounted needle placement manipulator, robot control software, robot controller, interventional planning workstation, and MRI scanner. The framework is modular in the sense that all components are connected independently, making it readily extensible and reconfigurable for supporting the clinical workflow of various interventional MRI procedures. Based on this framework we developed two body-mounted robots for musculoskeletal procedures. The first robot is a four-degree of freedom system called ArthroBot for shoulder arthrography in pediatric patients. The second robot is a six-degree of freedom system called PainBot for perineural injections used to treat pain in adult and pediatric patients. Body-mounted robots are designed with compact and lightweight structure so that they can be attached directly to the patient, which minimizes the effect of patient motion by allowing the robot to move with the patient. A dedicated clinical workflow is proposed for the MRI-guided musculoskeletal procedures using body-mounted robots. Initial cadaveric evaluations of both systems were performed to verify the feasibility of the systems and validate the clinical workflow.

7.
Int J Comput Assist Radiol Surg ; 15(2): 321-331, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31625021

RESUMO

PURPOSE: This paper presents the development of a body-mounted robotic assistant for magnetic resonance imaging (MRI)-guided low back pain injection. Our goal was to eliminate the radiation exposure of traditional X-ray guided procedures while enabling the exquisite image quality available under MRI. The robot is designed with a compact and lightweight profile that can be mounted directly on the patient's lower back via straps, thus minimizing the effect of patient motion by moving along with the patient. The robot was built with MR-conditional materials and actuated with piezoelectric motors so it can operate inside the MRI scanner bore during imaging and therefore streamline the clinical workflow by utilizing intraoperative MR images. METHODS: The robot is designed with a four degrees of freedom parallel mechanism, stacking two identical Cartesian stages, to align the needle under intraoperative MRI-guidance. The system targeting accuracy was first evaluated in free space with an optical tracking system, and further assessed with a phantom study under live MRI-guidance. Qualitative imaging quality evaluation was performed on a human volunteer to assess the image quality degradation caused by the robotic assistant. RESULTS: Free space positioning accuracy study demonstrated that the mean error of the tip position to be [Formula: see text] mm and needle angle to be [Formula: see text]. MRI-guided phantom study indicated the mean errors of the target to be [Formula: see text] mm, entry point to be [Formula: see text] mm, and needle angle to be [Formula: see text]. Qualitative imaging quality evaluation validated that the image degradation caused by the robotic assistant in the lumbar spine anatomy is negligible. CONCLUSIONS: The study demonstrates that the proposed body-mounted robotic system is able to perform MRI-guided low back injection in a phantom study with sufficient accuracy and with minimal visible image degradation that should not affect the procedure.


Assuntos
Dor Lombar/tratamento farmacológico , Procedimentos Cirúrgicos Robóticos , Humanos , Dor Lombar/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Fluxo de Trabalho
8.
IEEE Robot Autom Lett ; 5(4): 5245-5251, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33748414

RESUMO

This paper reports the improved design, system integration, and initial experimental evaluation of a fully actuated body-mounted robotic system for real-time MRI-guided lower back pain injections. The 6-DOF robot is composed of a 4-DOF needle alignment module and a 2-DOF remotely actuated needle driver module, which together provide a fully actuated manipulator that can operate inside the scanner bore during imaging. The system minimizes the need to move the patient in and out of the scanner during a procedure, and thus may shorten the procedure time and streamline the clinical workflow. The robot is devised with a compact and lightweight structure that can be attached directly to the patient's lower back via straps. This approach minimizes the effect of patient motion by allowing the robot to move with the patient. The robot is integrated with an image-based surgical planning module. A dedicated clinical workflow is proposed for robot-assisted lower back pain injections under real-time MRI guidance. Targeting accuracy of the system was evaluated with a real-time MRI-guided phantom study, demonstrating the mean absolute errors (MAE) of the tip position to be 1.50±0.68mm and of the needle angle to be 1.56±0.93°. An initial cadaver study was performed to validate the feasibility of the clinical workflow, indicating the maximum error of the position to be less than 1.90mm and of the angle to be less than 3.14°.

9.
IEEE Trans Biomed Eng ; 67(10): 2990-2999, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32078530

RESUMO

OBJECTIVE: Treatment of brain tumors requires high precision in order to ensure sufficient treatment while minimizing damage to surrounding healthy tissue. Ablation of such tumors using needle-based therapeutic ultrasound (NBTU) under real-time magnetic resonance imaging (MRI) can fulfill this need. However, the constrained space and strong magnetic field in the MRI bore restricts patient access limiting precise placement of the NBTU ablation tool. A surgical robot compatible with use inside the bore of an MRI scanner can alleviate these challenges. METHODS: We present preclinical trials of a robotic system for NBTU ablation of brain tumors under real-time MRI guidance. The system comprises of an updated robotic manipulator and corresponding control electronics, the NBTU ablation system and applications for planning, navigation and monitoring of the system. RESULTS: The robotic system had a mean translational and rotational accuracy of 1.39  ± 0.64 mm and 1.27 [Formula: see text] in gelatin phantoms and 3.13  ± 1.41 mm and 5.58 [Formula: see text] in 10 porcine trials while causing a maximum reduction in signal to noise ratio (SNR) of 10.3%. CONCLUSION: The integrated robotic system can place NBTU ablator at a desired target location in porcine brain and monitor the ablation in realtime via magnetic resonance thermal imaging (MRTI). SIGNIFICANCE: Further optimization of this system could result in a clinically viable system for use in human trials for various diagnostic or therapeutic neurosurgical interventions.


Assuntos
Procedimentos Cirúrgicos Robóticos , Robótica , Animais , Humanos , Imageamento por Ressonância Magnética , Imagens de Fantasmas , Razão Sinal-Ruído , Suínos
10.
J Med Robot Res ; 4(2)2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31485544

RESUMO

This paper presents the development, preclinical evaluation, and preliminary clinical study of a robotic system for targeted transperineal prostate biopsy under direct interventional magnetic resonance imaging (MRI) guidance. The clinically integrated robotic system is developed based on a modular design approach, comprised of surgical navigation application, robot control software, MRI robot controller hardware, and robotic needle placement manipulator. The system provides enabling technologies for MRI-guided procedures. It can be easily transported and setup for supporting the clinical workflow of interventional procedures, and the system is readily extensible and reconfigurable to other clinical applications. Preclinical evaluation of the system is performed with phantom studies in a 3 Tesla MRI scanner, rehearsing the proposed clinical workflow, and demonstrating an in-plane targeting error of 1.5mm. The robotic system has been approved by the institutional review board (IRB) for clinical trials. A preliminary clinical study is conducted with the patient consent, demonstrating the targeting errors at two biopsy target sites to be 4.0mm and 3.7mm, which is sufficient to target a clinically significant tumor foci. First-in-human trials to evaluate the system's effectiveness and accuracy for MR image-guide prostate biopsy are underway.

11.
Rep U S ; 2018: 1443-1448, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30997267

RESUMO

This paper presents a body-mounted, four degree-of-freedom (4-DOF) parallel mechanism robot for image-guided percutaneous interventions. The design of the robot is optimized to be light weight and compact such that it could be mounted to the patient body. It has a modular design that can be adopted for assisting various image-guided, needle-based percutaneous interventions such as arthrography, biopsy and brachytherapy seed placement. The robot mechanism and the control system are designed and manufactured with components compatible with imaging modalities including Magnetic Resonance Imaging (MRI) and Computed Tomography (CT). The current version of the robot presented in this paper is optimized for shoulder arthrography under MRI guidance; a Z-shaped fiducial frame is attached to the robot, providing accurate and repeatable robot registration with the MR scanner coordinate system. Here we present the mechanical design of the manipulator, robot kinematics, robot calibration procedure, and preliminary bench-top accuracy assessment. The bench-top accuracy evaluation of the robotic manipulator shows average translational error of 1.01 mm and 0.96 mm in X and Z axes, respectively, and average rotational error of 3.06 degrees and 2.07 degrees about the X and Z axes, respectively.

12.
Int J Comput Assist Radiol Surg ; 12(8): 1451-1460, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28567563

RESUMO

PURPOSE: With the growing interest in advanced image-guidance for surgical robot systems, rapid integration and testing of robotic devices and medical image computing software are becoming essential in the research and development. Maximizing the use of existing engineering resources built on widely accepted platforms in different fields, such as robot operating system (ROS) in robotics and 3D Slicer in medical image computing could simplify these tasks. We propose a new open network bridge interface integrated in ROS to ensure seamless cross-platform data sharing. METHODS: A ROS node named ROS-IGTL-Bridge was implemented. It establishes a TCP/IP network connection between the ROS environment and external medical image computing software using the OpenIGTLink protocol. The node exports ROS messages to the external software over the network and vice versa simultaneously, allowing seamless and transparent data sharing between the ROS-based devices and the medical image computing platforms. RESULTS: Performance tests demonstrated that the bridge could stream transforms, strings, points, and images at 30 fps in both directions successfully. The data transfer latency was <1.2 ms for transforms, strings and points, and 25.2 ms for color VGA images. A separate test also demonstrated that the bridge could achieve 900 fps for transforms. Additionally, the bridge was demonstrated in two representative systems: a mock image-guided surgical robot setup consisting of 3D slicer, and Lego Mindstorms with ROS as a prototyping and educational platform for IGT research; and the smart tissue autonomous robot surgical setup with 3D Slicer. CONCLUSION: The study demonstrated that the bridge enabled cross-platform data sharing between ROS and medical image computing software. This will allow rapid and seamless integration of advanced image-based planning/navigation offered by the medical image computing software such as 3D Slicer into ROS-based surgical robot systems.


Assuntos
Robótica/instrumentação , Software , Cirurgia Assistida por Computador/instrumentação , Redes de Comunicação de Computadores , Humanos , Robótica/métodos , Cirurgia Assistida por Computador/métodos
13.
Annu Int Conf IEEE Eng Med Biol Soc ; 2015: 4869-74, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26737384

RESUMO

Magnetic resonance imaging (MRI) provides excellent image contrast for various types of tissues, making it a suitable choice over other imaging modalities for various image-guided needle interventions. Furthermore, robot-assistance is maturing for surgical procedures such as percutaneous prostate and brain interventions. Although MRI-guided, robot-assisted needle interventions are approaching clinical usage, they are still typically open-loop in nature due to the lack of continuous intraoperative needle tracking. Closed-loop needle-based procedures can improve the accuracy of needle tip placement by correcting the needle trajectory during insertion. This paper proposes a system for robot-assisted, flexible asymmetric-tipped needle interventions under continuous intraoperative MRI guidance. A flexible needle's insertion depth and rotation angle are manipulated by an MRI-compatible robot in the bore of the MRI scanner during continuous multi-planar image acquisition to reach a desired target location. Experiments are performed on gelatin phantoms to assess the accuracy of needle placement into the target location. The system was able to successfully utilize live MR imaging to guide the path of the needle, and results show an average total targeting error of 2.5±0.47mm, with an average in-plane error of 2.09±0.33mm.


Assuntos
Imagem por Ressonância Magnética Intervencionista/métodos , Agulhas , Procedimentos Cirúrgicos Robóticos/instrumentação , Procedimentos Cirúrgicos Robóticos/métodos , Algoritmos , Desenho de Equipamento , Retroalimentação , Humanos , Processamento de Imagem Assistida por Computador , Imagem por Ressonância Magnética Intervencionista/instrumentação , Imagens de Fantasmas