Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
BMC Med Imaging ; 15: 48, 2015 Oct 27.
Artigo em Inglês | MEDLINE | ID: mdl-26502883

RESUMO

BACKGROUND: The purpose of this study was to see how coronary magnetic resonance angiography (CMRA) compared to echocardiography for the detection of coronary artery origins and to compare CMRA measurements for coronary dimensions in children with published echocardiographic reference values. METHODS: Enrolled patients underwent dual cardiac phase CMRA and echocardiography under the same anesthetic. Echocardiographic measurements of the right coronary artery (RCA), left anterior descending (LAD) and left main (LM) were made. CMRA dimensions were assessed manually at the same points as the echocardiographic measurements. The number of proximal LAD branches imaged was also recorded in order to give an estimate of distal coronary tree visualization. RESULTS: Fifty patients (24 boys, mean age 4.0 years (range 18 days to 18 years)) underwent dual-phase CMRA. Coronary origins were identified in 47/50 cases for CMRA (remaining 3 were infants aged 3, 9 and 11 months). In comparison, origins were identified in 41/50 cases for echo (remaining were all older children). CMRA performed better than echocardiography in terms of distal visualization of the coronary tree (median 1 LAD branch vs. median 0; p = 0.001). Bland-Altman plots show poor agreement between echocardiography and CMRA for coronary measurements. CMRA measurements did vary according to cardiac phase (systolic mean 1.90, s.d. 0.05 mm vs. diastolic mean 1.84, s.d. 0.05 mm; p = 0.002). CONCLUSIONS: Dual-phase CMRA has an excellent (94 %) success rate for the detection of coronary origins in children. Newborn infants remain challenging and echocardiography remains the accepted imaging modality for this age group. Echocardiographic reference ranges are not applicable to CMRA measurements as agreement was poor between modalities. Future coronary reference values, using any imaging modality, should quote the phase in which it was measured.


Assuntos
Angiografia Coronária/métodos , Vasos Coronários/anatomia & histologia , Ecocardiografia/métodos , Angiografia por Ressonância Magnética/métodos , Adolescente , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Tamanho do Órgão , Estudos Prospectivos , Sensibilidade e Especificidade
2.
Eur Heart J ; 35(22): 1486-95, 2014 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-24419806

RESUMO

AIMS: To provide a comprehensive histopathological validation of cardiac magnetic resonance (CMR) and endocardial voltage mapping of acute and chronic atrial ablation injury. METHODS AND RESULTS: 16 pigs underwent pre-ablation T2-weighted (T2W) and late gadolinium enhancement (LGE) CMR and high-density voltage mapping of the right atrium (RA) and both were repeated after intercaval linear radiofrequency ablation. Eight pigs were sacrificed following the procedure for pathological examination. A further eight pigs were recovered for 8 weeks, before chronic CMR, repeat RA voltage mapping and pathological examination. Signal intensity (SI) thresholds from 0 to 15 SD above a reference SI were used to segment the RA in CMR images and segmentations compared with real lesion volumes. The SI thresholds that best approximated histological volumes were 2.3 SD for LGE post-ablation, 14.5 SD for T2W post-ablation and 3.3 SD for LGE chronically. T2-weighted chronically always underestimated lesion volume. Acute histology showed transmural injury with coagulative necrosis. Chronic histology showed transmural fibrous scar. The mean voltage at the centre of the ablation line was 3.3 mV pre-ablation, 0.6 mV immediately post-ablation, and 0.3 mV chronically. CONCLUSION: This study presents the first histopathological validation of CMR and endocardial voltage mapping to define acute and chronic atrial ablation injury, including SI thresholds that best match histological lesion volumes. An understanding of these thresholds may allow a more informed assessment of the underlying atrial substrate immediately after ablation and before repeat catheter ablation for atrial arrhythmias.


Assuntos
Ablação por Cateter/efeitos adversos , Eletrodiagnóstico/métodos , Traumatismos Cardíacos/patologia , Angiografia por Ressonância Magnética/métodos , Doença Aguda , Animais , Técnicas de Imagem Cardíaca/métodos , Doença Crônica , Meios de Contraste , Feminino , Átrios do Coração/patologia , Compostos Organometálicos , Suínos , Porco Miniatura
3.
Radiology ; 264(1): 242-9, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22589322

RESUMO

PURPOSE: To investigate whether a dual inversion-recovery (IR) prepulse improves scar-to-blood contrast and expert confidence and consistency at late gadolinium-enhanced magnetic resonance (MR) imaging of myocardial scar compared with the standard IR technique at 3.0 T. MATERIALS AND METHODS: The study was approved by the local ethics committee, and all patients provided written informed consent. Twelve men (mean age±standard deviation, 63 years±8) with known myocardial scar underwent MR imaging 10, 20, and 30 minutes after administration of 0.2 mmol/kg gadobutrol with a standard and dual IR sequence. Contrast-to-noise ratios (CNRs) were measured by using region-of-interest analysis, and data were compared with the analysis of variance test. Two experts measured scar size and transmurality, and data were compared with the Student t test and Bland-Altman test. Experts assigned confidence scores for scar detection and transmurality, which were compared with a Wilcoxon matched-pairs signed rank test. RESULTS: Patient data showed improved scar-to-blood CNR for the dual IR technique compared with the standard IR technique at all time points (P<.05). For images obtained 20 minutes after contrast material administration, the dual IR sequence provided higher confidence scores for scar detection and transmurality assessment (P<.05) and resulted in more consistent assessment of scar size and transmurality between readers compared with the IR sequence (P<.05). CONCLUSION: In this preliminary patient study, the dual IR prepulse improved contrast, scar visualization, and expert confidence and reduced expert differences in transmurality and scar size assessment compared with the standard IR technique.


Assuntos
Cicatriz/patologia , Imageamento por Ressonância Magnética/métodos , Infarto do Miocárdio/patologia , Análise de Variância , Meios de Contraste , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Compostos Organometálicos , Software , Estatísticas não Paramétricas
4.
J Magn Reson Imaging ; 35(4): 969-75, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22170809

RESUMO

PURPOSE: To compare cross-sectional and in-plane coronary vessel wall imaging using a spiral readout at 1.5 and 3 Tesla (T). MATERIALS AND METHODS: Free-breathing coronary vessel wall imaging using a local inversion technique and spiral readout was implemented. Images were acquired in ten healthy adult subjects on a 3T clinical scanner using a 32-element cardiac coil and repeated on a 1.5T clinical scanner using a 5-element coil. RESULTS: Cross-sectional and in-plane spiral vessel wall imaging was performed at both 1.5 and 3T. In cross-sectional images, artifact scores were superior at 1.5T (P < 0.05) but no significant difference was found in image quality scores compared with 3T. Image quality (P < 0.01) and artifact scores (P < 0.01) were found to be superior for in-plane images at 1.5T. Vessel wall sharpness in the in-plane orientation was also found to be higher at 1.5T (P < 0.03). CONCLUSION: Although excellent in-plane coronary vessel wall images can be acquired at 3T, the overall robustness may be affected by off-resonance blurring due to increased B0 inhomogeneity compared with 1.5T.


Assuntos
Algoritmos , Vasos Coronários/anatomia & histologia , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Angiografia por Ressonância Magnética/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
5.
J Magn Reson Imaging ; 34(2): 279-85, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21780223

RESUMO

PURPOSE: To demonstrate the utility of a "reduced field-of-view" (zoom imaging) technique to accelerate free-breathing, ECG-triggered, turbo-spin-echo black-blood sequences, which have been previously described to detect subclinical aortic atherosclerosis. MATERIALS AND METHODS: Fifteen healthy volunteers underwent MRI of the thoracic and abdominal aorta. Imaging with the conventional full field-of-view sequence was compared with zoom imaging. Total scan time, image quality (i.e., contrast-to-noise ratio and vessel wall sharpness) and vessel wall thickness were analyzed. A subgroup of 10 volunteers also underwent acceleration of imaging using sensitivity encoding (SENSE) for comparison. RESULTS: Zoom imaging significantly reduced imaging time from a mean of 41 ± 9 min (conventional imaging) to 15 ± 0.5 min (P<0.01). There was no difference in image quality between conventional and zoom imaging with respect to CNR (10.1 ± 6 versus 10.1 ± 6) or vessel wall sharpness (38 ± 4% versus 39 ± 4%). Furthermore, Bland Altman plots showed excellent agreement in vessel wall thickness measurements using the two methods. In comparison, SENSE not only reduced CNR but also resulted in underestimation of vessel wall thickness compared with the conventional sequence. CONCLUSION: Zoom imaging allows accurate and time-efficient imaging of the abdominal and thoracic aorta for cardiovascular risk prediction. In this application, it is preferable to SENSE.


Assuntos
Aorta/patologia , Aterosclerose/patologia , Doenças Cardiovasculares/diagnóstico , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Doenças Cardiovasculares/patologia , Diagnóstico por Imagem/métodos , Eletrocardiografia/métodos , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Risco , Medição de Risco , Fatores de Risco
6.
J Magn Reson Imaging ; 34(5): 1176-83, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21953627

RESUMO

PURPOSE: To accelerate and optimize black blood properties of the quadruple inversion recovery (QIR) technique for imaging the abdominal aortic wall. MATERIALS AND METHODS: QIR inversion delays were optimized for different heart rates in simulations and phantom studies by minimizing the steady state magnetization of blood for T(1) = 100-1400 ms. To accelerate and improve black blood properties of aortic vessel wall imaging, the QIR prepulse was combined with zoom imaging and (a) "traditional" and (b) "trailing" electrocardiogram (ECG) triggering. Ten volunteers were imaged pre- and post-contrast administration using a conventional ECG-triggered double inversion recovery (DIR) and the two QIR implementations in combination with a zoom-TSE readout. RESULTS: The QIR implemented with "trailing" ECG-triggering resulted in consistently good blood suppression as the second inversion delay was timed during maximum systolic flow in the aorta. The blood signal-to-noise ratio and vessel wall to blood contrast-to-noise ratio, vessel wall sharpness, and image quality scores showed a statistically significant improvement compared with the traditional QIR implementation with and without ECG-triggering. CONCLUSION: We demonstrate that aortic vessel wall imaging can be accelerated with zoom imaging and that "trailing" ECG-triggering improves black blood properties of the aorta which is subject to motion and variable blood flow during the cardiac cycle.


Assuntos
Aorta/patologia , Eletrocardiografia/métodos , Imageamento por Ressonância Magnética/métodos , Artefatos , Simulação por Computador , Meios de Contraste/farmacologia , Endotélio Vascular/patologia , Frequência Cardíaca , Humanos , Processamento de Imagem Assistida por Computador/métodos , Magnetismo , Modelos Estatísticos , Imagens de Fantasmas , Reprodutibilidade dos Testes
7.
Nucl Med Commun ; 28(4): 305-13, 2007 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-17325595

RESUMO

BACKGROUND: Although Tc-dimercaptosuccinic acid (DMSA) scans are routinely used to quantify relative renal function, no quantification method is universally adopted. Audits using real patient data indicate reasonable consistency but, as the true relative function is unknown, accuracy cannot be assessed. The aim was to simulate realistic DMSA images that can be used to assess accuracy. METHODS: Anatomical models were created from computed tomography (CT) scans of a patient who had also undergone DMSA imaging. Organs that take up DMSA were outlined on CT and each assigned an activity concentration (with renal cortex and medulla modelled separately). The simulated images were visually compared to the patient's clinical images and subtracted to identify differences. Iteration was used on the posterior image to find the organ activities that produced the most realistic simulated image. The optimal activity distribution was then used to also simulate an anterior image. To assess the simulations, the percentage difference was calculated between the counts in each kidney on the real and simulated images. RESULTS: Visually, the clinical and simulated images appear similar and the subtracted images indicate only small differences. The percentage difference in kidney counts between the images was less than 1% for both kidneys on the posterior image and less than 5% on the anterior image. The cortex and medulla activity concentrations were approximately equal. CONCLUSION: A technique for realistic simulation of DMSA images has been devised and should prove useful for evaluating image analysis software.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Rim/diagnóstico por imagem , Rim/metabolismo , Modelos Biológicos , Ácido Dimercaptossuccínico Tecnécio Tc 99m/farmacocinética , Simulação por Computador , Humanos , Cintilografia , Compostos Radiofarmacêuticos/farmacocinética
8.
JACC Cardiovasc Imaging ; 7(8): 762-70, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25051945

RESUMO

OBJECTIVES: This study investigated the feasibility of visual and quantitative assessment of coronary vessel wall contrast enhancement (CE) for detection of symptomatic atherosclerotic coronary artery disease (CAD) and subclinical coronary vasculitis in autoimmune inflammatory disease (systemic lupus erythematosus [SLE]), as well as the association with aortic stiffness, an established marker of risk. BACKGROUND: Coronary CE by cardiac magnetic resonance (CMR) is a novel noninvasive approach to visualize gadolinium contrast uptake within the coronary artery vessel wall. METHODS: A total of 75 subjects (CAD: n = 25; SLE: n = 27; control: n = 23) underwent CMR imaging using a 3-T clinical scanner. Coronary arteries were visualized by a T2-prepared steady state free precession technique. Coronary wall CE was visualized using inversion-recovery T1 weighted gradient echo sequence 40 min after administration of 0.2 mmol/kg gadobutrol. Proximal coronary segments were visually examined for distribution of CE and quantified for contrast-to-noise ratio (CNR) and total CE area. RESULTS: Coronary CE was prevalent in patients (93%, n = 42) with a diffuse pattern for SLE and a patchy/regional distribution in CAD patients. Compared with control subjects, CNR values and total CE area in patients with CAD and SLE were significantly higher (mean CNR: 3.9 ± 2.5 vs. 6.9 ± 2.5 vs. 6.8 ± 2.0, respectively; p < 0.001; total CE area: median 0.8 [interquartile range (IQR): 0.6 to 1.2] vs. 3.2 [IQR: 2.6 to 4.0] vs. 3.3 [IQR: 1.9 to 4.5], respectively; p < 0.001). Both measures were positively associated with aortic stiffness (CNR: r = 0.61, p < 0.01; total CE area: 0.36, p = 0.03), hypercholesterolemia (r = 0.68, p < 0.001; r = 0.61, p < 0.001) and hypertension (r = 0.40, p < 0.01; r = 0.32, p < 0.05). CONCLUSIONS: We demonstrate that quantification of coronary CE by CNR and total CE area is feasible for detection of subclinical and clinical uptake of gadolinium within the coronary vessel wall. Coronary vessel wall CE may become an instrumental novel direct marker of vessel wall injury and remodeling in subpopulations at risk.


Assuntos
Aterosclerose/patologia , Meios de Contraste , Angiografia Coronária/métodos , Doença da Artéria Coronariana/patologia , Vasos Coronários/patologia , Lúpus Eritematoso Sistêmico/complicações , Angiografia por Ressonância Magnética , Compostos Organometálicos , Vasculite/patologia , Adulto , Aterosclerose/etiologia , Aterosclerose/fisiopatologia , Estudos de Casos e Controles , Doença da Artéria Coronariana/etiologia , Doença da Artéria Coronariana/fisiopatologia , Estudos de Viabilidade , Feminino , Humanos , Hipercolesterolemia , Interpretação de Imagem Assistida por Computador , Lúpus Eritematoso Sistêmico/diagnóstico , Lúpus Eritematoso Sistêmico/fisiopatologia , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Placa Aterosclerótica , Valor Preditivo dos Testes , Remodelação Vascular , Rigidez Vascular , Vasculite/etiologia , Vasculite/fisiopatologia
9.
Circ Cardiovasc Imaging ; 6(1): 91-8, 2013 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-23223637

RESUMO

BACKGROUND: Coronary allograft vasculopathy is the leading cause of late death after heart transplantation in children. It is poorly detected by conventional angiography. Intravascular ultrasound is invasive and costly. This study shows that magnetic resonance imaging (MRI) late gadolinium enhancement (LGE) of the coronary vessel wall can detect and grade coronary allograft vasculopathy. METHODS AND RESULTS: Twenty-four children (10 male; age range, 9-17 years) underwent coronary angiography, intravascular ultrasound, and MRI. Maximal intimal thickness and mean intimal index were recorded. MRI included coronary magnetic resonance angiogram and LGE vessel wall imaging with 1.5 T (n=12) and 3.0 T (n=12). Ten healthy control subjects also underwent LGE MRI. Mean time posttransplantation was 5.5 years (range, 0.25-14 years). Seven patients had Stanford grade IV coronary allograft vasculopathy on intravascular ultrasound, 3 of whom had angiographic disease. Maximal intimal thickness and mean intimal index were 0.73±0.50 mm and 20.9±10.6%, respectively. On MRI, mean diameter of enhancement of vessel wall was 6.57±4.91 mm, and mean enhancement index (indexed to vessel lumen size) was 1.10±1.72. The control group showed little or no LGE. Correlation of LGE with maximal intimal thickness using the Pearson coefficient was 0.80 (P<0.001) and with mean intimal index was 0.92 (P<0.001). An MRI diameter >7.5 mm gave 86% sensitivity and 93% specificity. CONCLUSIONS: LGE scores correlate well with traditional intravascular ultrasound measures. These promising early results encourage larger-scale clinical studies to investigate whether LGE MRI will allow closer follow-up and better prevention of coronary allograft vasculopathy in children.


Assuntos
Meios de Contraste , Doença da Artéria Coronariana/diagnóstico , Vasos Coronários/patologia , Rejeição de Enxerto/diagnóstico , Transplante de Coração , Imagem Cinética por Ressonância Magnética/métodos , Compostos Organometálicos , Adolescente , Criança , Pré-Escolar , Feminino , Seguimentos , Gadolínio , Humanos , Lactente , Masculino , Reprodutibilidade dos Testes , Transplante Homólogo
10.
ISRN Ophthalmol ; 2013: 264604, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24558601

RESUMO

Aim. To evaluate the profile of ocular gaze abnormalities occurring following stroke. Methods. Prospective multicentre cohort trial. Standardised referral and investigation protocol including assessment of visual acuity, ocular alignment and motility, visual field, and visual perception. Results. 915 patients recruited: mean age 69.18 years (SD 14.19). 498 patients (54%) were diagnosed with ocular motility abnormalities. 207 patients had gaze abnormalities including impaired gaze holding (46), complete gaze palsy (23), horizontal gaze palsy (16), vertical gaze palsy (17), Parinaud's syndrome (8), INO (20), one and half syndrome (3), saccadic palsy (28), and smooth pursuit palsy (46). These were isolated impairments in 50% of cases and in association with other ocular abnormalities in 50% including impaired convergence, nystagmus, and lid or pupil abnormalities. Areas of brain stroke were frequently the cerebellum, brainstem, and diencephalic areas. Strokes causing gaze dysfunction also involved cortical areas including occipital, parietal, and temporal lobes. Symptoms of diplopia and blurred vision were present in 35%. 37 patients were discharged, 29 referred, and 141 offered review appointments. 107 reviewed patients showed full recovery (4%), partial improvement (66%), and static gaze dysfunction (30%). Conclusions. Gaze dysfunction is common following stroke. Approximately one-third of patients complain of visual symptoms, two thirds show some improvement in ocular motility.

11.
Biomed Res Int ; 2013: 719096, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24089687

RESUMO

AIMS: To profile site of stroke/cerebrovascular accident, type and extent of field loss, treatment options, and outcome. METHODS: Prospective multicentre cohort trial. Standardised referral and investigation protocol of visual parameters. RESULTS: 915 patients were recruited with a mean age of 69 years (SD 14). 479 patients (52%) had visual field loss. 51 patients (10%) had no visual symptoms. Almost half of symptomatic patients (n = 226) complained only of visual field loss: almost half (n = 226) also had reading difficulty, blurred vision, diplopia, and perceptual difficulties. 31% (n = 151) had visual field loss as their only visual impairment: 69% (n = 328) had low vision, eye movement deficits, or visual perceptual difficulties. Occipital and parietal lobe strokes most commonly caused visual field loss. Treatment options included visual search training, visual awareness, typoscopes, substitutive prisms, low vision aids, refraction, and occlusive patches. At followup 15 patients (7.5%) had full recovery, 78 (39%) had improvement, and 104 (52%) had no recovery. Two patients (1%) had further decline of visual field. Patients with visual field loss had lower quality of life scores than stroke patients without visual impairment. CONCLUSIONS: Stroke survivors with visual field loss require assessment to accurately define type and extent of loss, diagnose coexistent visual impairments, and offer targeted treatment.


Assuntos
Acidente Vascular Cerebral/patologia , Acidente Vascular Cerebral/terapia , Transtornos da Visão/patologia , Transtornos da Visão/terapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Qualidade de Vida , Acidente Vascular Cerebral/complicações , Reabilitação do Acidente Vascular Cerebral , Transtornos da Visão/etiologia , Campos Visuais
12.
Int J Stroke ; 6(5): 404-11, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21609413

RESUMO

BACKGROUND: Ocular causes of reading impairment following stroke include visual field loss, eye movement impairment and poor central vision. Non ocular causes may include cognitive errors or language impairment. AIM: The purpose of this study was to identify all patients referred with suspected visual impairment who had reported reading difficulty to establish the prevalence of ocular and non ocular causes. METHODS: Prospective, multicentre, observation study with standardised referral and assessment forms across 21 sites. Visual assessment included visual acuity measurement, visual field assessment, ocular alignment, and movement and visual inattention assessment. Multicentre ethical approval and informed patient consent were obtained. RESULTS: A total of 915 patients were recruited, with a mean age of 69·18 years (standard deviation 14·19). Reading difficulties were reported by 177 patients (19·3%), with reading difficulty as the only symptom in 39 patients. Fifteen patients had normal visual assessment but with a diagnosis of expressive or receptive aphasia. Eight patients had alexia. One hundred and nine patients had visual field loss, 85 with eye movement abnormality, 27 with low vision and 39 patients with visual perceptual impairment. Eighty-seven patients had multiple ocular diagnoses with combined visual field, eye movement, low vision or inattention problems. All patients with visual impairment were given targeted treatment and/or advice including prisms, occlusion, refraction, low vision aids and scanning exercises. CONCLUSIONS: Patients complaining of reading difficulty were mostly found to have visual impairment relating to low vision, eye movement or visual field loss. A small number were found to have non ocular causes of reading difficulty. Treatment or advice was possible for all patients with visual impairment.


Assuntos
Agnosia/etiologia , Dislexia Adquirida/etiologia , Hemianopsia/etiologia , Transtornos da Motilidade Ocular/etiologia , Leitura , Acidente Vascular Cerebral/complicações , Idoso , Idoso de 80 Anos ou mais , Agnosia/fisiopatologia , Afasia/etiologia , Dislexia Adquirida/fisiopatologia , Dislexia Adquirida/reabilitação , Óculos , Feminino , Hemianopsia/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Transtornos da Motilidade Ocular/fisiopatologia , Transtornos da Motilidade Ocular/reabilitação , Ortóptica , Estudos Prospectivos , Acidente Vascular Cerebral/fisiopatologia , Acuidade Visual , Campos Visuais , Percepção Visual
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA