Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Eur Radiol ; 34(2): 842-851, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37606664

RESUMO

OBJECTIVES: To explore the use of deep learning-constrained compressed sensing (DLCS) in improving image quality and acquisition time for 3D MRI of the brachial plexus. METHODS: Fifty-four participants who underwent contrast-enhanced imaging and forty-one participants who underwent unenhanced imaging were included. Sensitivity encoding with an acceleration of 2 × 2 (SENSE4x), CS with an acceleration of 4 (CS4x), and DLCS with acceleration of 4 (DLCS4x) and 8 (DLCS8x) were used for MRI of the brachial plexus. Apparent signal-to-noise ratios (aSNRs), apparent contrast-to-noise ratios (aCNRs), and qualitative scores on a 4-point scale were evaluated and compared by ANOVA and the Friedman test. Interobserver agreement was evaluated by calculating the intraclass correlation coefficients. RESULTS: DLCS4x achieved higher aSNR and aCNR than SENSE4x, CS4x, and DLCS8x (all p < 0.05). For the root segment of the brachial plexus, no statistically significant differences in the qualitative scores were found among the four sequences. For the trunk segment, DLCS4x had higher scores than SENSE4x (p = 0.04) in the contrast-enhanced group and had higher scores than SENSE4x and DLCS8x in the unenhanced group (all p < 0.05). For the divisions, cords, and branches, DLCS4x had higher scores than SENSE4x, CS4x, and DLCS8x (all p ≤ 0.01). No overt difference was found among SENSE4x, CS4x, and DLCS8x in any segment of the brachial plexus (all p > 0.05). CONCLUSIONS: In three-dimensional MRI for the brachial plexus, DLCS4x can improve image quality compared with SENSE4x and CS4x, and DLCS8x can maintain the image quality compared to SENSE4x and CS4x. CLINICAL RELEVANCE STATEMENT: Deep learning-constrained compressed sensing can improve the image quality or accelerate acquisition of 3D MRI of the brachial plexus, which should be benefit in evaluating the brachial plexus and its branches in clinical practice. KEY POINTS: •Deep learning-constrained compressed sensing showed higher aSNR, aCNR, and qualitative scores for the brachial plexus than SENSE and CS at the same acceleration factor with similar scanning time. •Deep learning-constrained compressed sensing at acceleration factor of 8 had comparable aSNR, aCNR, and qualitative scores to SENSE4x and CS4x with approximately half the examination time. •Deep learning-constrained compressed sensing may be helpful in clinical practice for improving image quality and acquisition time in three-dimensional MRI of the brachial plexus.


Assuntos
Plexo Braquial , Aprendizado Profundo , Humanos , Imageamento Tridimensional/métodos , Plexo Braquial/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Razão Sinal-Ruído
2.
J Foot Ankle Surg ; 2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38679411

RESUMO

The present study was to determine the characteristics of the ankle skeletal structure in patients with talus Hepple V type. We conducted a retrospective study on the skeletal structure of the talus in 110 patients with Hepple V osteochondral lesions of the talus and in control participants. The radiographic measurements taken include the following: in the coronal plane - depth of talus frontal curvature, length of the lateral and medial malleolus; in the sagittal plane - radius and height of talus, angle of tibial lateral surface, tibiotalar sector, and vertical neck angle. The osteochondral lesion of the talus showed a significantly larger mean radius (mean ± SD, 21.4 ± 2.5 mm; p < .001) and height (mean ± SD, 26.0 ± 2.7 mm; p < .005). It also demonstrated a longer mean medial malleolus length (mean ± SD, 15.7 ± 2.4 mm; p < .005), a larger mean vertical neck angle (mean ± SD, 86.2 ± 5.4°; p < .050), and a greater mean tibial lateral surface angle (mean ± SD, 80.0 ± 4.5°; p < .001). And there was a greater mean frontal curvature depth (mean ± SD, 3.9 ± 0.6 mm; p < .005). Overall, this study found that patients with Hepple V osteochondral lesions of the talus had a larger vertical neck angle and tibial lateral surface angle, a longer talus radius and medial malleolus length, a higher talus height, and a deeper frontal curvature depth. STUDY DESIGNS: Retrospective Case-Control Study.

3.
Eur Radiol ; 33(4): 2500-2509, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36355200

RESUMO

OBJECTIVES: To compare the image quality of three-dimensional breath-hold magnetic resonance cholangiopancreatography with deep learning-based compressed sensing reconstruction (3D DL-CS-MRCP) to those of 3D breath-hold MRCP with compressed sensing (3D CS-MRCP), 3D breath-hold MRCP with gradient and spin-echo (3D GRASE-MRCP) and conventional 2D single-shot breath-hold MRCP (2D MRCP). METHODS: In total, 102 consecutive patients who underwent MRCP at 3.0 T, including 2D MRCP, 3D GRASE-MRCP, 3D CS-MRCP, and 3D DL-CS-MRCP, were prospectively included. Two radiologists independently analyzed the overall image quality, background suppression, artifacts, and visualization of pancreaticobiliary ducts using a five-point scale. The signal-to-noise ratio (SNR) of the common bile duct (CBD), contrast-to-noise ratio (CNR) of the CBD and liver, and contrast ratio between the periductal tissue and CBD were measured. The Friedman test was performed to compare the four protocols. RESULTS: 3D DL-CS-MRCP resulted in improved SNR and CNR values compared with those in the other three protocols, and better contrast ratio compared with that in 3D CS-MRCP and 3D GRASE-MRCP (all, p < 0.05). Qualitative image analysis showed that 3D DL-CS-MRCP had better performance for second-level intrahepatic ducts and distal main pancreatic ducts compared with 3D CS-MRCP (all, p < 0.05). Compared with 2D MRCP, 3D DL-CS-MRCP demonstrated better performance for the second-order left intrahepatic duct but was inferior in assessing the main pancreatic duct (all, p < 0.05). Moreover, the image quality was significantly higher in 3D DL-CS-MRCP than in 3D GRASE-MRCP. CONCLUSION: 3D DL-CS-MRCP has superior performance compared with that of 3D CS-MRCP or 3D GRASE-MRCP. Deep learning reconstruction also provides a comparable image quality but with inferior main pancreatic duct compared with that revealed by 2D MRCP. KEY POINTS: • 3D breath-hold MRCP with deep learning reconstruction (3D DL-CS-MRCP) demonstrated improved image quality compared with that of 3D MRCP with compressed sensing or GRASE. • Compared with 2D MRCP, 3D DL-CS-MRCP had superior performance in SNR and CNR, better visualization of the left second-level intrahepatic bile ducts, and comparable overall image quality, but an inferior main pancreatic duct.


Assuntos
Aprendizado Profundo , Pancreatopatias , Humanos , Imageamento Tridimensional/métodos , Colangiopancreatografia por Ressonância Magnética/métodos , Ductos Pancreáticos/diagnóstico por imagem
4.
Eur Radiol ; 33(9): 6267-6277, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37036481

RESUMO

OBJECTIVE: This study aimed to assess biventricular function and mechanics in patients with the chronic high-altitude disease (CHAD) using cardiovascular MRI and explore the possible risk factors associated with ventricular remodeling. METHODS: In this prospective study, consecutive CHAD patients and healthy controls at high-altitude (HA) and at sea level (SL) underwent cardiovascular MRI. Right ventricular (RV) and left ventricular (LV) function and global strain parameters were compared. To identify risk factors associated with ventricular remodeling, multiple linear regression analyses were used. RESULTS: A total of 33 patients with CHAD (42.97 years ± 11.80; 23 men), 33 HA (41.18 years ± 8.58; 21 men), and 33 SL healthy controls (43.48 years ± 13.40; 21 men) were included. A Significantly decreased biventricular ejection fraction was observed in patients (all p < 0.05). Additionally, the HA group displayed lower magnitudes of biventricular longitudinal peak strain (PS) (RV, - 13.67% ± 4.05 vs. - 16.22% ± 3.03; LV, - 14.68% ± 2.20 vs. - 16.19% ± 2.51; both p < 0.05), but a higher LV circumferential PS (- 20.74% ± 2.02 vs. - 19.17% ± 2.34, p < 0.05) than the SL group. Moreover, multiple linear regression analyses revealed that HGB (ß = 0.548) was related to the LV remodeling index, whereas BUN (ß = 0.570) was associated with the RV remodeling index. CONCLUSIONS: With the deterioration of RV function in patients with CHAD, LV function was also impaired concomitantly. Hypoxia-induced erythrocytosis may contribute to LV impairment, while BUN was considered an independent risk factor for RV remodeling. KEY POINTS: • A significantly lower biventricular ejection fraction was observed in patients, with a decreased magnitude of left ventricular (LV) peak systolic strain rate (radial and circumferential) and peak diastolic strain rate (all p < 0.05). • High-altitude healthy natives showed a lower biventricular longitudinal peak strain (all p < 0.05). • Hemoglobin was related to LV remodeling (ß = 0.548), while BUN (ß = 0.570) was independently associated with RV remodeling in CHAD patients.


Assuntos
Altitude , Disfunção Ventricular Esquerda , Masculino , Humanos , Remodelação Ventricular , Estudos Prospectivos , Coração , Imageamento por Ressonância Magnética/efeitos adversos , Função Ventricular Esquerda
5.
Eur Radiol ; 32(2): 1044-1053, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34477909

RESUMO

OBJECTIVES: To investigate the feasibility of automatic machine learning (autoML) based on native T1 mapping to predict late gadolinium enhancement (LGE) status in hypertrophic cardiomyopathy (HCM). METHODS: Ninety-one HCM patients and 44 healthy controls who underwent cardiovascular MRI were enrolled. The native T1 maps of HCM patients were classified as LGE ( +) or LGE (-) based on location-matched LGE images. An autoML pipeline was implemented using the tree-based pipeline optimization tool (TPOT) for 3 binary classifications: LGE ( +) and LGE (-), LGE (-) and control, and HCM and control. TPOT modeling was repeated 10 times to obtain the optimal model for each classification. The diagnostic performance of the best models by slice and by case was evaluated using sensitivity, specificity, accuracy, and microaveraged area under the curve (AUC). RESULTS: Ten prediction models were generated by TPOT for each of the 3 binary classifications. The diagnostic accuracy obtained with the best pipeline in detecting LGE status in the testing cohort of HCM patients was 0.80 by slice and 0.79 by case. In addition, the TPOT model also showed discriminability between LGE (-) patients and control (accuracy: 0.77 by slice; 0.78 by case) and for all HCM patients and controls (accuracy: 0.88 for both). CONCLUSIONS: Native T1 map analysis based on autoML correlates with LGE ( +) or (-) status. The TPOT machine learning algorithm could be a promising method for predicting myocardial fibrosis, as reflected by the presence of LGE in HCM patients without the need for late contrast-enhanced MRI sequences. KEY POINTS: • The tree-based pipeline optimization tool (TPOT) is a machine learning algorithm that could help predict late gadolinium enhancement (LGE) status in patients with hypertrophic cardiomyopathy. • The TPOT could serve as an adjuvant method to detect LGE by using information from native T1 maps, thus avoiding the need for contrast agent. • The TPOT also detects native T1 map alterations in LGE-negative patients with hypertrophic cardiomyopathy.


Assuntos
Cardiomiopatia Hipertrófica , Meios de Contraste , Cardiomiopatia Hipertrófica/complicações , Cardiomiopatia Hipertrófica/diagnóstico por imagem , Fibrose , Gadolínio , Humanos , Aprendizado de Máquina , Imagem Cinética por Ressonância Magnética , Miocárdio/patologia
6.
Eur Radiol ; 32(11): 7647-7656, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35567605

RESUMO

OBJECTIVES: We aimed to evaluate myocardial fibrosis using cardiac magnetic resonance (CMR) T1 mapping in type 2 diabetes mellitus (T2DM) patients and investigate the association between left ventricular (LV) subclinical myocardial dysfunction and myocardial fibrosis. METHODS: The study included 37 short-term (≤ 5 years) and 44 longer-term (> 5 years) T2DM patients and 41 healthy controls. The LV global strain parameters and T1 mapping parameters were compared between the abovementioned three groups. The association of T1 mapping parameters with diabetes duration, in addition to other risk factors, was determined using multivariate linear regression analysis. The correlation between LV strain parameters and T1 mapping parameters was evaluated using Pearson's correlation. RESULTS: The peak diastolic strain rates (PDSRs) were significantly lower in longer-term T2DM patients compared to those in healthy subjects and short-term T2DM patients (p < 0.05). The longitudinal peak systolic strain rate and peak strain were significantly lower in the longer-term T2DM compared with the short-term T2DM group (p < 0.05). The extracellular volumes (ECVs) were higher in both subgroups of T2DM patients compared with control subjects (all p < 0.05). Multivariate linear regression analysis showed that diabetes duration was independently associated with ECV (ß = 0.413, p < 0.001) by taking covariates into account. Pearson's analysis showed that ECV was associated with longitudinal PDSR (r = - 0.441, p < 0.001). CONCLUSION: T1 mapping could detect abnormal myocardial fibrosis early in patients with T2DM, which can cause a decline in the LV diastolic function. KEY POINTS: • CMR T1 mapping could detect abnormal myocardial fibrosis early in patients with T2DM. • The diabetes duration was independently associated with ECV. • Myocardial fibrosis can cause a decline in the LV diastolic function in T2DM patients.


Assuntos
Cardiomiopatias , Diabetes Mellitus Tipo 2 , Disfunção Ventricular Esquerda , Humanos , Diabetes Mellitus Tipo 2/patologia , Imagem Cinética por Ressonância Magnética/efeitos adversos , Disfunção Ventricular Esquerda/complicações , Disfunção Ventricular Esquerda/diagnóstico por imagem , Função Ventricular Esquerda , Miocárdio/patologia , Fibrose , Espectroscopia de Ressonância Magnética , Valor Preditivo dos Testes
7.
J Magn Reson Imaging ; 54(1): 284-289, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33433045

RESUMO

The safety profiles when performing stress oxygenation-sensitive magnetic resonance imaging (OS-MRI) have raised concerns in clinical practice. Adenosine infusion can cause side effects such as chest pain, dyspnea, arrhythmia, and even cardiac death. The aim of this study was to investigate the feasibility of breathing maneuvers-induced OS-MRI in acute myocardial infarction (MI). This was a prospective study, which included 14 healthy rabbits and nine MI rabbit models. This study used 3 T MRI/modified Look-Locker inversion recovery sequence for native T1 mapping, balanced steady-state free precession sequence for OS imaging, and phase-sensitive inversion recovery sequence for late gadolinium enhancement. The changes in myocardial oxygenation (ΔSI) were assessed under two breathing maneuvers protocols in healthy rabbits: a series of extended breath-holding (BH), and a combined maneuver of hyperventilation followed by the extended BH (HVBH). Subsequently, OS-MRI with HVBH in acute MI rabbits was performed, and the ΔSI was compared with that of adenosine stress protocol. Student's t-test, Wilcoxon rank test, and Friedman test were used to compare ΔSI in different subgroups. Pearson and Spearman correlation was used to obtain the association of ΔSI between breathing maneuvers and adenosine stress. Bland-Altman analysis was used to assess the bias of ΔSI between HVBH and adenosine stress. In healthy rabbits, BH maneuvers from 30 to 50 s induced significant increase in SI compared with the baseline (all p < 0.05). By contrast, hyperventilation for 60 s followed by 10 s-BH (HVBH 10 s) exhibited a comparable ΔSI to that of stress test (p = 0.07). In acute MI rabbits, HVBH 10 s-induced ΔSIs among infarcted, salvaged, and the remote myocardial area were no less effectiveness than adenosine stress when performing OS-MRI (r = 0.84; p < 0.05). Combined breathing maneuvers with OS-MRI have the potential to be used as a nonpharmacological alternative for assessing myocardial oxygenation in patients with acute MI. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY STAGE: 2.


Assuntos
Imagem Cinética por Ressonância Magnética , Infarto do Miocárdio , Animais , Meios de Contraste , Gadolínio , Humanos , Imageamento por Ressonância Magnética , Infarto do Miocárdio/diagnóstico por imagem , Miocárdio , Estudos Prospectivos , Coelhos
8.
Eur Radiol ; 31(12): 8956-8966, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34003352

RESUMO

OBJECTIVES: To explore the relationships between oxygenation signal intensity (SI) with myocardial inflammation and regional left ventricular (LV) remodeling in reperfused acute ST-segment elevation myocardial infarction (STEMI) using oxygenation-sensitive cardiovascular magnetic resonance (OS-CMR). METHODS: Thirty-three STEMI patients and 22 age- and sex-matched healthy volunteers underwent CMR. The protocol included cine function, OS imaging, precontrast T1 mapping, T2 mapping, and late gadolinium enhancement (LGE) imaging. A total of 880 LV segments were included for analysis based on the American Heart Association 16-segment model. For validation, 15 pigs (10 myocardial infarction (MI) model animals and 5 controls) received CMR and were sacrificed for immunohistochemical analysis. RESULTS: In the patient study, the acute oxygenation SI showed a stepwise rise among remote, salvaged, and infarcted segments compared with healthy myocardium. At convalescence, all oxygenation SI values besides those in infarcted segments with microvascular obstruction decreased to similar levels. Acute oxygenation SI was associated with early myocardial injury (T1: r = 0.38; T2: r = 0.41; all p < 0.05). Segments with higher acute oxygenation SI values exhibited thinner diastolic walls and decreased wall thickening during follow-up. Multivariable regression modeling indicated that acute oxygenation SI (ß = 2.66; p < 0.05) independently predicted convalescent segment adverse remodeling (LV wall thinning). In the animal study, alterations in oxygenation SI were correlated with histological inflammatory infiltrates (r = 0.59; p < 0.001). CONCLUSIONS: Myocardial oxygenation by OS-CMR could be used as a quantitative imaging biomarker to assess myocardial inflammation and predict convalescent segment adverse remodeling after STEMI. KEY POINTS: • Oxygenation signal intensity (SI) may be an imaging biomarker of inflammatory infiltration that could be used to assess the response to anti-inflammatory therapies in the future. • Oxygenation SI early after myocardial infarction (MI) was associated with left ventricular segment injury at acute phase and could predict regional functional recovery and adverse remodeling late after acute MI. • Oxygenation SI demonstrated a stepwise increase among remote, salvaged, and infarcted segments. Infarcted zones with microvascular obstruction demonstrated a higher oxygenation SI than those without. However, the former showed less pronounced changes over time.


Assuntos
Infarto do Miocárdio , Infarto do Miocárdio com Supradesnível do Segmento ST , Animais , Meios de Contraste , Gadolínio , Humanos , Inflamação/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética , Infarto do Miocárdio/diagnóstico por imagem , Miocárdio , Valor Preditivo dos Testes , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico por imagem , Suínos , Função Ventricular Esquerda , Remodelação Ventricular
9.
J Cardiovasc Magn Reson ; 23(1): 23, 2021 03 11.
Artigo em Inglês | MEDLINE | ID: mdl-33691727

RESUMO

BACKGROUND: Secondary hyperparathyroidism is a common complication of end-stage renal disease (ESRD), which may be associated with cardiovascular diseases. Thus, this study aimed to explore myocardial damage using non-contrast cardiovascular magnetic resonance (CMR) in ESRD patients undergoing hemodialysis and further investigate its relationship with parathyroid hormone (PTH) toxicity. METHODS: Seventy-two adult ESRD patients receiving regular hemodialysis and 30 healthy subjects underwent CMR examination. Continuous CMR cine sections from the mitral valve level to the left ventricular (LV) apex in the short-axis plane, cine series of vertical two-chamber long-axis plane, and horizontal four-chamber plane were acquired. Native T1 mapping was obtained using modified Look-Locker inversion recovery (MOLLI) sequences. Native T1 values and myocardial strain were analyzed.  Immunoreactive parathyroid hormone (iPTH) was obtained from all enrolled patients. RESULTS: Forty (55.6%) hemodialysis ESRD patients were found to have increased iPTH levels. LV ejection fraction (LVEF) of both ESRD patients with targeted and increased iPTH levels was decreased compared with healthy subjects (55.9 ± 12.0% vs. 65.0 ± 4.5%; 51.7 ± 12.8 vs. 65.0 ± 4.5%, both P < 0.05). The mean peak radial strain (PRS), peak circumferential strain (PCS), and peak longitudinal strain (PLS) were lowest in ESRD patients with increased iPTH; however, no significant difference was observed among these three groups. Segmentally, from base to apex, the native T1 of ESRD patients with increased iPTH levels tended to be higher than those with targeted iPTH and healthy subjects (all P < 0.05). In ESRD patients with targeted iPTH, both native T1 of basal and middle segments were significantly higher than normal subjects (basal, 1304 ± 41 ms vs. 1238 ± 36 ms, P = 0.001; middle, 1300 ± 43 ms vs. 1242 ± 50 ms, P < 0.001). Comparing global native T1 values in the three groups, ESRD patients with targeted and increased iPTH level showed increased native T1 (1305 ± 41 ms vs. 1251 ± 49 ms, P = 0.001; 1334 ± 40 ms vs. 1251 ± 49 ms, P < 0.001, respectively). Native T1 values of the basal segment and global native T1 were moderately associated with iPTH (r = 0.4, P < 0.001; r = 0.5, P < 0.001). Multiple linear regression analysis showed that global native T1 values (beta = 1.0, P = 0.01) were independently associated with iPTH. CONCLUSIONS: Elevated iPTH level was associated with and was an independent risk factor for myocardial damage in ESRD patients undergoing maintenance hemodialysis. TRIAL REGISTRATION: Chinese Clinical Trial Registry ( http://www.chictr.org.cn/index.aspx ) ChiCTR-DND-17012976, 13/12/2017, retrospectively registered.


Assuntos
Cardiopatias/diagnóstico por imagem , Hiperparatireoidismo Secundário/sangue , Falência Renal Crônica/terapia , Imagem Cinética por Ressonância Magnética , Miocárdio/patologia , Hormônio Paratireóideo/sangue , Diálise Renal , Adulto , Idoso , Biomarcadores/sangue , Estudos de Casos e Controles , Feminino , Cardiopatias/etiologia , Cardiopatias/patologia , Cardiopatias/fisiopatologia , Humanos , Hiperparatireoidismo Secundário/diagnóstico , Hiperparatireoidismo Secundário/etiologia , Falência Renal Crônica/complicações , Falência Renal Crônica/diagnóstico , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Diálise Renal/efeitos adversos , Medição de Risco , Fatores de Risco , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento , Regulação para Cima , Função Ventricular Esquerda
10.
Sichuan Da Xue Xue Bao Yi Xue Ban ; 52(5): 819-824, 2021 Sep.
Artigo em Zh | MEDLINE | ID: mdl-34622599

RESUMO

OBJECTIVE: To explore the diagnostic performance of deep learning (DL) model in early detection of the interstitial myocardial fibrosis using native T1 maps of hypertrophic cardiomyopathy (HCM) without late gadolinium enhancement (LGE). METHODS: Sixty HCM patients and 44 healthy volunteers who underwent cardiac magnetic resonance were enrolled in this study. Each native T1 map was labeled according to its LGE status. Then, native T1 maps of LGE (-) and those of the controls were preprocessed and entered in the SE-ResNext-50 model as the matrix for the DL model for training, validation and testing. RESULTS: A total of 241 native T1 maps were entered in the SE-ResNext-50 model. The model achieved a specificity of 0.87, sensitivity of 0.79, and area under curve ( AUC) of 0.83 ( P<0.05) in distinguishing native T1 maps of LGE (-) from those of the controls in the testing set. CONCLUSION: The DL model based on SE-ResNext-50 could be used for identifying native T1 maps of LGE (-) with relatively high accuracy. It is a promising approach for early detection of myocardial fibrosis in HCM without the use of contrast agent.


Assuntos
Cardiomiopatia Hipertrófica , Aprendizado Profundo , Cardiomiopatia Hipertrófica/diagnóstico por imagem , Meios de Contraste , Fibrose , Gadolínio , Humanos
11.
Sichuan Da Xue Xue Bao Yi Xue Ban ; 52(1): 92-97, 2021 Jan.
Artigo em Zh | MEDLINE | ID: mdl-33474896

RESUMO

OBJECTIVE: To evaluate the diagnostic value of 3.0T time-of-flight MR angiography with sparse undersampling and iterative reconstruction (TOFu-MRA) for unruptured intracranial aneurysms (UIAs) on the basis of using digital subtraction angiography (DSA) as the reference standard. METHODS: A total of 65 patients with suspected UIAs were prospectively enrolled and all patients underwent TOFu-MRA and DSA. Relying on DSA as the reference standard, the sensitivity (SEN), specificity (SPE), positive predictive value (PPV) and negative predictive value (NPV) of using TOFu-MRA in UIA diagnosis were calculated, and the inter-observer agreement between two doctors was determined. Comparison of maximum intensity projection (MIP) and volume rendering (VR) image datasets was made to evaluate the agreement between DSA results and TOFu-MRA in the measurement of UIA morphological parameters, including the neck width (D neck), height (H) , and width (D width) of UIAs. RESULTS: The study covered 55 UIAs from 46 patients. The SEN, SPE, PPV and NPV of the two doctors using TOFu-MRA in UIA diagnosis were as follows: (95.7%, 95.7%), (94.7%, 94.7%), (97.8%, 97.8%) and (90.0%, 90.0%), respectively for patient-based assessment; (96.4%, 94.5%), (94.7%, 94.7%), (98.1%, 98.1%) and (90.0%, 85.7%), respectively, for aneurysm-based assessment. There is a strong inter-observer agreement (Kappa=0.93 for patient-based assessment and 0.96 for aneurysm-based assessment) between the two doctors. Moreover, Bland-Altman analysis showed that more than 95% points fell within the limits of agreement (LoA), suggesting strong agreement between the two examination methods for the measurement of UIAs morphological parameters. CONCLUSION: TOFu-MRA showed good diagnostic efficacy for UIAs and the results were in good agreement with those of DSA, the reference standard, for assessing UIA morphological parameter. TOFu-MRA can be used as a first choice for noninvasive diagnostic evaluation of UIAs.


Assuntos
Aneurisma Intracraniano , Angiografia por Ressonância Magnética , Angiografia Digital , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X
12.
Sichuan Da Xue Xue Bao Yi Xue Ban ; 52(2): 286-292, 2021 Mar.
Artigo em Zh | MEDLINE | ID: mdl-33829704

RESUMO

OBJECTIVE: To evaluate the noise reduction effect of deep learning-based reconstruction algorithms in thin-section chest CT images by analyzing images reconstructed with filtered back projection (FBP), adaptive statistical iterative reconstruction (ASIR), and deep learning image reconstruction (DLIR) algorithms. METHODS: The chest CT scan raw data of 47 patients were included in this study. Images of 0.625 mm were reconstructed using six reconstruction methods, including FBP, ASIR hybrid reconstruction (ASIR50%, ASIR70%), and deep learning low, medium and high modes (DL-L, DL-M, and DL-H). After the regions of interest were outlined in the aorta, skeletal muscle and lung tissue of each group of images, the CT values, SD values and signal-to-noise ratio (SNR) of the regions of interest were measured, and two radiologists evaluated the image quality. RESULTS: CT values, SD values and SNR of the images obtained by the six reconstruction methods showed statistically significant difference ( P<0.001). There were statistically significant differences in the image quality scores of the six reconstruction methods ( P<0.001). Images reconstruced with DL-H have the lowest noise and the highest overall quality score. CONCLUSION: The model based on deep learning can effectively reduce the noise of thin-section chest CT images and improve the image quality. Among the three deep-learning models, DL-H showed the best noise reduction effect.


Assuntos
Aprendizado Profundo , Algoritmos , Humanos , Processamento de Imagem Assistida por Computador , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador , Tomografia Computadorizada por Raios X
13.
Sichuan Da Xue Xue Bao Yi Xue Ban ; 52(2): 293-299, 2021 Mar.
Artigo em Zh | MEDLINE | ID: mdl-33829705

RESUMO

OBJECTIVE: To compare the noise reduction performance of conventional filtering and artificial intelligence-based filtering and interpolation (AIFI) and to explore for optimal parameters of applying AIFI in the noise reduction of abdominal magnetic resonance imaging (MRI). METHODS: Sixty patients who underwent upper abdominal MRI examination in our hospital were retrospectively included. The raw data of T1-weighted image (T1WI), T2-weighted image (T2WI), and dualecho sequences were reconstructed with two image denoising techniques, conventional filtering and AIFI of different levels of intensity. The difference in objective image quality indicators, peak signal-to-noise ratio (pSNR) and image sharpness, of the different denoising techniques was compared. Two radiologists evaluated the image noise, contrast, sharpness, and overall image quality. Their scores were compared and the interobserver agreement was calculated. RESULTS: Compared with the original images, improvement of varying degrees were shown in the pSNR and the sharpness of the images of the three sequences, T1W1, T2W2, and dual echo sequence, after denoising filtering and AIFI were used (all P<0.05). In addition, compared with conventional filtering, the objective quality scores of the reconstructed images were improved when conventional filtering was combined with AIFI reconstruction methods in T1WI sequence, AIFI level≥3 was used in T2WI and echo1 sequence, and AIFI level≥4 was used in echo2 sequence (all P<0.05). The subjective scores given by the two radiologists for the image noise, contrast, sharpness, and overall image quality in each sequence of conventional filtering reconstruction, AIFI reconstruction (except for AIFI level=1), and two-method combination reconstruction were higher than those of the original images (all P<0.05). However, the image contrast scores were reduced for AIFI level=5. There was good interobserver agreement between the two radiologists (all r>0.75, P<0.05). After multidimensional comparison, the optimal parameters of using AIFI technique for noise reduction in abdominal MRI were conventional filtering+AIFI level=3 in the T1WI sequence and AIFI level=4 in the T2WI and dualecho sequences. CONCLUSION: AIFI is superior to filtering in imaging denoising at medium and high levels. It is a promising noise reduction technique. The optimal parameters of using AIFI for abdominal MRI are Filtering+AIFI level=3 in the T1WI sequence and AIFI level=4 in T2WI and dualecho sequences.


Assuntos
Inteligência Artificial , Imageamento por Ressonância Magnética , Algoritmos , Humanos , Processamento de Imagem Assistida por Computador , Estudos Retrospectivos
14.
Sichuan Da Xue Xue Bao Yi Xue Ban ; 52(2): 306-310, 2021 Mar.
Artigo em Zh | MEDLINE | ID: mdl-33829707

RESUMO

OBJECTIVE: To assess the clinical effectiveness of boundary recognition of upper abdomen organs on CT images based on neural network model and the combination of different slices. METHODS: A total of 2 000 patients who underwent upper abdomen enhanced CT scans from March 2018 to March 2019 were included in the study. The quality of the CT images met the requirements for clinical diagnosis. Eight boundary layers (the upper and lower edge of liver, the upper and lower edge of spleen, the lower edge of left kidney, the lower edge of right kidney, the lower edge of the stomach and the lower edge of the gallbladder) of the main organs in the upper abdomen were labeled. The model training (training set, verification set and test set) based on different neural network methods and combinations of different slices were then performed to assess the accuracy of boundary recognition. Furthermore, clinical data from 50 cases were used as test group for assessing the accuracy and clinical effectiveness of this model. RESULTS: The fusion model created by integrating the two models according to different weight ratios yielded the highest accuracy, and then followed the EfficientNet-b3 model, with the Xception model showing the lowest accuracy. In each model, the boundary recognition accuracy of 5-slice image is higher than that of 3-silce image, and that of 1-slice image is the lowest. The recognition accuracy of fusion model of the 5-continuous-slice image for upper edge of liver, lower edge of liver, upper edge of spleen, lower edge of spleen, lower edge of left kidney, lower edge of right kidney, lower edge of stomach and lower edge of gallbladder was 91%, 87%, 92%, 85%, 92%, 95%, 76% and 74%, respectively. The fusion model was checked with the effectiveness data of 50 cases, yielding 88%, 86%, 88%, 80%, 82%, 80%, 69%, and 65% accuracy for 8-slice image, respectively, and the accuracy of meeting clinical application requirement was as high as 98%, 98%, 95%, 98%, 99%, 98%, 80% and 77%, respectively. CONCLUSION: By increasing boundary change logics in the continuous slices, the fusion model integrating different weight proportions demonstrates the highest accuracy for identifying the boundary of upper abdominal organs on CT images, achieving high examination effectiveness in clinical practice.


Assuntos
Redes Neurais de Computação , Tomografia Computadorizada por Raios X , Abdome/diagnóstico por imagem , Humanos , Baço/diagnóstico por imagem , Resultado do Tratamento
15.
Sichuan Da Xue Xue Bao Yi Xue Ban ; 52(5): 807-812, 2021 Sep.
Artigo em Zh | MEDLINE | ID: mdl-34622597

RESUMO

OBJECTIVE: To explore the clinical feasibility of applying deep learning (DL) reconstruction algorithm in low-dose thin-slice liver CT examination of healthy volunteers by comparing the reconstruction algorithm based on DL, filtered back projection (FBP) reconstruction algorithm and iterative reconstruction (IR) algorithm. METHODS: A standard water phantom with a diameter of 180 mm was scanned, using the 160 slice multi-detector CT scanning of United Imaging Healthcare, to compare the noise power spectrums of DL, FBP and IR algorithms. 100 healthy volunteers were prospectively enrolled, with 50 assigned to the normal dose group (ND) and 50 to the low dose group (LD). IR algorithm was used in the ND group to reconstruct images, while DL, FBP and IR algorithms were used in the LD group to reconstruct images. One-way analysis of variance was used to compare the liver CT values, the liver noise, liver signal-to-noise ratio (SNR), contrast noise ratio (CNR) and figure of merit (FOM) of the images of ND-IR, LD-FBP, LD-IR and LD-DL. The Kruskal-Wallis test was used to analyse subjective scores of anatomical structures. RESULTS: The DL algorithm had the lowest average peak value of noise power spectrum, and its shape was similar to that of medium-level IR algorithm. Liver CT values of ND-IR, LD-FBP, LD-IR and LD-DL did not show statistically significant difference. The noise of LD-DL was lower than that of LD-FBP, LD-IR and ND-IR ( P<0.05), and the SNR, CNR and FOM of LD-DL were higher than those of LD-FBP, LD-IR and ND-IR ( P<0.05). The subjective scores of anatomical structures of LD-DL did not show significant difference compared to those of ND-IR ( P >0.05), and were higher than those of LD-FBP and LD-IR. The radiation dose of the LD group was reduced by about 50.2% compared with that of the ND group. CONCLUSION: The DL algorithm with noise shape similar to the medium iterative grade IR commonly used in clinical practice showed higher noise reduction ability than IR did. Compared with FBP, the DL algorithm had smoother noise shape, but much better noise reduction ability. The application of DL algorithm in low-dose thin-slice liver CT of healthy volunteers can help achieve the standard image quality of liver CT.


Assuntos
Aprendizado Profundo , Algoritmos , Voluntários Saudáveis , Humanos , Fígado/diagnóstico por imagem , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador , Tomografia Computadorizada por Raios X
17.
BMC Cardiovasc Disord ; 20(1): 12, 2020 01 10.
Artigo em Inglês | MEDLINE | ID: mdl-31924159

RESUMO

BACKGROUND: End-stage renal disease (ESRD) patients are at high cardiovascular risk, and myocardial fibrosis (MF) accounts for most of their cardiac events. The purpose of this study is to investigate the prognostic value and risk stratification of MF as measured by extracellular volume (ECV) on cardiac magnetic resonance (CMR) for heart failure (HF) in patients with hemodialysis-dependent ESRD. METHODS: Sixty-six hemodialysis ESRD patients and 25 matched healthy volunteers were prospectively enrolled and underwent CMR to quantify multiple parameters of MF by T1 mapping and late gadolinium enhancement (LGE). All ESRD patients were followed up for 11-30 months, and the end-point met the 2016 ESC guidelines for the definition of HF. RESULTS: Over a median follow-up of 18 months (range 11-30 months), there were 26 (39.39%) guideline-diagnosed HF patients in the entire cohort of ESRD subjects. The native T1 value was elongated, and ECV was enlarged in the HF cohort relative to the non-HF cohort and normal controls (native T1, 1360.10 ± 50.14 ms, 1319.39 ± 55.44 ms and 1276.35 ± 56.56 ms; ECV, 35.42 ± 4.42%, 31.85 ± 3.01% and 26.97 ± 1.87%; all p<0.05). In the cardiac strain analysis, ECV was significantly correlated with global radial strain (GRS) (r = - 0.501, p = 0.009), global circumferential strain (GCS) (r = 0.553, p = 0.005) and global longitudinal strain (GLS) (r = 0.507, p = 0.008) in ESRD patients with HF. Cox proportional hazard regression models revealed that ECV (hazard ratio [HR] = 1.160, 95% confidence interval: 1.022 to 1.318, p = 0.022) was the only independent predictor of HF in ESRD patients. It also had a higher diagnostic accuracy for detecting MF (area under the curve [AUC] = 0.936; 95% confidence interval: 0.864 to 0.976) than native T1 and post T1 (all p ≤ 0.002). Kaplan-Meier analysis revealed that the high-ECV group had a shorter median overall survival time than the low-ECV group (18 months vs. 20 months, log-rank p = 0.046) and that ESRD patients with high ECV were more likely to have HF. CONCLUSIONS: Myocardial fibrosis quantification by ECV on CMR T1 mapping was shown to be an independent risk factor of heart failure, providing incremental prognostic value and risk stratification for cardiac events in ESRD patients. TRIAL REGISTRATION: Chinese Clinical Trial Registry ChiCTR-DND-17012976, 13/12/2017, Retrospectively registered.


Assuntos
Insuficiência Cardíaca/diagnóstico por imagem , Falência Renal Crônica/terapia , Imagem Cinética por Ressonância Magnética , Miocárdio/patologia , Diálise Renal , Remodelação Ventricular , Adulto , Idoso , Estudos de Casos e Controles , Feminino , Fibrose , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/patologia , Insuficiência Cardíaca/fisiopatologia , Humanos , Falência Renal Crônica/complicações , Falência Renal Crônica/diagnóstico , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Estudos Prospectivos , Diálise Renal/efeitos adversos , Medição de Risco , Fatores de Risco
18.
Sichuan Da Xue Xue Bao Yi Xue Ban ; 50(4): 571-576, 2019 Jul.
Artigo em Zh | MEDLINE | ID: mdl-31642238

RESUMO

OBJECTIVE: To determine the value of automated detection in computed tomography angiography (CTA) for cases with greater than 70% coronary stenosis. METHODS: Fifty-seven patients who had both coronary CTA and digital subtraction angiography (DSA) were retrospectively recruited in this study. The patients were categorized into two groups using a cutoff value of 70% stenosis in DSA. The AW4.6 software was used to estimate the diameter and square values from the data obtained from CTA. The sensitivity (SE), specificity (SPE), positive predictive value (PPV) and negative predictive value (NPV) of the automated CTA estimations were calculated. RESULTS: A total of 178 vessels from the 57 patients were analyzed. The automated CTA estimations had moderate to high levels of agreements (Kappa value: 0.716-0.804, P < 0.001) with the DSA diagnoses, compared with low to moderate levels of agreements (Kappa value: 0.385-0.533, P < 0.001) in manual interpretations. The square estimations generated high SE (100%) and NPV (100%) for patient diagnoses (P < 0.016 7 vs. manual interpretations). The diameter estimations generated high SPE (90.48%) and PPV (94.12%) for patient diagnoses (P < 0.016 7, vs. manual interpretations). Similarly, high SE (96.92%) and NPV (97.89%) were found for square estimations in vessel diagnoses, while high SPE (94.69%) and PPV (90.16%) were found for diameter estimations in vessel diagnoses. CONCLUSIONS: Both automated diameter and square algorithms have high accuracy for diagnosing patients with greater than 70% coronary artery stenosis. The AW4.6 can improve the detection of severe stenosis that needs stent interventions.


Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária , Estenose Coronária/diagnóstico por imagem , Angiografia Digital , Humanos , Estudos Retrospectivos , Sensibilidade e Especificidade
19.
Sichuan Da Xue Xue Bao Yi Xue Ban ; 50(6): 878-883, 2019 Dec.
Artigo em Zh | MEDLINE | ID: mdl-31880121

RESUMO

ObstractPurpose "One-stop" CT myocardial perfusion imaging (CT-MPI) was compared with cardiac magnetic resonance(CMR) to investigate its application value in evaluating patients with severe coronary artery stenosis.MethodsFifty patients with coronary artery stenosis≥90% of at least one major coronary arteries comfirmed by coronary angiography (CAG) in the department of cardiology in our hospital, who referred for coronary artery stent implantation were prospectively enrolled. All the patients underwent "One-stop" CT-MPI within a week before surgery, among which 22 patients underwent CMR examination simultaneously. The postprocessing software Ziostation2 was used to obatin and compare the perfusion parameters of patients with normal and perfusion defect myocardium, including blood flow (BF), blood volume (BV), peak time (TTP), and mean transit time (MTT). Pearson correlation analysis was used to compare the correlation of relative perfusion parameters (defect/normal myocardium) between CT and CMR. Bland-Altman analysis was used to analyze the consistency between CT and CMR in left ventricular (LV) function parameters measurements.ResultsCompared with normal myocardium, BV and BF of perfusion defect myocardium were significantly decreased, while MTT and TTP were significantly prolonged (all P < 0.05). The rBV, rBF, rMTT and rTTP were medium to high positive correlated between CT and CMR (r=0.685, 0.641, 0.871, 0.733, respectively, all P < 0.05). Bland-Altman analysis showed that 95% (21/22) points were within the 95% limits of agreement (LoA), suggesting the LV function parameters measurements between two methods were highly consistent.Conclusion"One-stop" CT-MPI can simultaneously obtain the information about coronary anatomy, myocardial perfusion and LV function. It is of great value in the evaluation of patients with severe coronary artery stenosis, with shorter scan time and less contraindications compared with CMR.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Imagem de Perfusão do Miocárdio , Angiografia Coronária , Humanos , Valor Preditivo dos Testes , Tomografia Computadorizada por Raios X
20.
J Magn Reson Imaging ; 47(5): 1406-1414, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29044903

RESUMO

BACKGROUND: Both acute and chronic myocardial infarction (AMI and CMI, respectively) exhibit delayed enhancement; however, clinical decision-making processes frequently require the differentiation of these two types of myocardial injury. PURPOSE: To investigate the reliability of AMI and CMI characterization using native T1 mapping and its feasibility for discriminating AMI from CMI. STUDY TYPE: Case-control. ANIMAL MODEL: The study cohort comprised 12 AMI (mean post-MI, 3.75 ± 1.29 days) and 15 CMI (mean post-MI, 39.53 ± 6.10 days) Bama mini-pigs. FIELD STRENGTH/SEQUENCE: Balanced steady-state free precession (bSSFP), segmented-turbo-FLASH-PSIR, and modified Look-Locker inversion recovery (MOLLI) sequences at 3.0T. ASSESSMENT: The infarct sizes were compared on matching short-axis slices of late-gadolinium-enhanced (LGE) images and T1 maps by two experienced radiologists. STATISTICAL TESTS: The infarct sizes were compared on matching short-axis slices of LGE images and T1 maps, and agreement was determined using linear regression and Bland-Altman analyses. The native T1 values were compared between AMI and CMI models (independent sample t-test). The intraclass correlation coefficient was used to assess inter- and intraobserver variability. RESULTS: Measured infarct sizes did not differ between native T1 mapping and LGE images (AMI: P = 0.913; CMI: P = 0.233), and good agreement was observed between the two techniques (AMI: bias, -3.38 ± 19.38%; R2 = 0.96; CMI: bias, -10.55 ± 10.90%; R2 = 0.90). However, the native infarction myocardium T1 values and the T1 signal intensity ratio of infarct and remote myocardium (T1 SI ratio) did not differ significantly between AMI and CMI (P = 0.173). DATA CONCLUSION: Noncontrast native T1 mapping can accurately determine acute and chronic infarct areas as well as conventional LGE imaging; however, it cannot distinguish acute from chronic MI. LEVEL OF EVIDENCE: 1 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018;47:1406-1414.


Assuntos
Imageamento por Ressonância Magnética , Infarto do Miocárdio/diagnóstico por imagem , Animais , Meios de Contraste , Tomada de Decisões , Sistemas de Apoio a Decisões Clínicas , Modelos Animais de Doenças , Gadolínio , Interpretação de Imagem Assistida por Computador/métodos , Modelos Lineares , Imagem Cinética por Ressonância Magnética , Miocárdio , Variações Dependentes do Observador , Radiologia/métodos , Análise de Regressão , Reprodutibilidade dos Testes , Suínos , Porco Miniatura , Temperatura
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA