1.
Cytometry A ; 97(7): 674-680, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32488957

RESUMO

In response to the recent COVID-19 pandemic, many laboratories are involved in research supporting SARS-CoV-2 vaccine development and clinical trials. Flow cytometry laboratories will be responsible for a large part of this effort by sorting unfixed antigen-specific lymphocytes. Therefore, it is critical and timely that we have an understanding of risk assessment and established procedures of infectious cell sorting. Here we present procedures covering the biosafety aspects of sorting unfixed SARS-CoV-2-infected cells and other infectious agents of similar risk level. These procedures follow the ISAC Biosafety Committee guidelines and were recently approved by the National Institutes of Health Institutional Biosafety Committee for sorting SARS-CoV-2-infected cells. © 2020 International Society for Advancement of Cytometry.


Assuntos
Betacoronavirus/isolamento & purificação , Contenção de Riscos Biológicos/métodos , Infecções por Coronavirus/prevenção & controle , Citometria de Fluxo/métodos , Pandemias/prevenção & controle , Pneumonia Viral/prevenção & controle , Manejo de Espécimes/métodos , COVID-19 , Infecções por Coronavirus/diagnóstico , Humanos , Laboratórios/normas , Pessoal de Laboratório Médico/normas , Pneumonia Viral/diagnóstico , Medição de Risco , SARS-CoV-2
2.
Cytometry A ; 95(2): 173-182, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30561906

RESUMO

Today's state-of-the-art cell sorting flow cytometers are equipped with aerosol containment systems designed to evacuate aerosols from the sort chamber during a sort. This biosafety device is especially important when the sort operator is sorting infectious or potentially infections samples. Hence, it is critical to evaluate the performance for this system in normal operation and in "failure" mode to determine the efficacy of containment. In the past decade, the most popular published method for evaluating containment has been the Glo-Germ bead procedure. These highly fluorescent and multisize particles can easily be detected on a microscope slide and enumerated using a fluorescent microscope. Collecting particles on this slide is accomplished using an Aerotech impactor. This sampler collects potentially escaping aerosols from the sort chamber before enumerating any particles. Although the Glo-Germ procedure has been adopted by many labs, there are several drawbacks with the procedure that have limited its adoption by cell sorter laboratories: The Aerotech impactor is a reusable device that requires rigorous cleaning between measurements. The surface area of the collection slide is large and difficult to scan on a fluorescence microscope. These beads produce a wide variation in sizes resulting in inconsistency in flow rates. Here, we describe a novel and replacement method utilizing a Cyclex-d impactor and Dragon Green beads. This method was compared for sensitivity of detection of escaped aerosols with a published method for aerosol detection which utilizes a UV-APS aerodynamic particle sizer and a UV-excitable dye. One of the advantages of the Cyclex-d system is the narrow-defined field of collection as compared to the standard Glo-Germ bead procedure, this means a smaller sampling area is used in the Cyclex-d impactor as compared to the AeroTech impactor. In addition, the sensitivity of detection was found to be better using the Cyclex-d collection device as compared to the standard Glo-Germ bead procedure. © 2018 International Society for Advancement of Cytometry.


Assuntos
Aerossóis/análise , Bioensaio/métodos , Citometria de Fluxo/métodos , Substâncias Perigosas/química , Separação Celular/métodos , Contenção de Riscos Biológicos/métodos , Contaminação de Equipamentos/prevenção & controle , Desenho de Equipamento/métodos , Laboratórios , Microscopia de Fluorescência/métodos , Microesferas , Tamanho da Partícula
3.
Cytometry A ; 93(11): 1087-1091, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30244531

RESUMO

We demonstrate improved methods for making valid and accurate comparisons of fluorescence measurement capabilities among instruments tested at different sites and times. We designed a suite of measurements and automated data processing methods to obtain consistent objective results and applied them to a selection of 23 instruments at nine sites to provide a range of instruments as well as multiple instances of similar instruments. As far as we know, this study represents the most accurate methods and results so far demonstrated for this purpose. The first component of the study reporting improved methods for photoelectron scale (Spe) evaluations, which was published previously (Parks, El Khettabi, Chase, Hoffman, Perfetto, Spidlen, Wood, Moore, and Brinkman: Cytometry A 91 (2017) 232-249). Those results which were within themselves are not sufficient for instrument comparisons, so here, we use the Spe scale results for the 23 cytometers and combine them with additional information from the analysis suite to obtain the metrics actually needed for instrument evaluations and comparisons. We adopted what we call the 2+2SD limit of resolution as a maximally informative metric, for evaluating and comparing dye measurement sensitivity among different instruments and measurement channels. Our results demonstrate substantial differences among different classes of instruments in both dye response and detection sensitivity and some surprisingly large differences among similar instruments, even among instruments with nominally identical configurations. On some instruments, we detected defective measurement channels needing service. The system can be applied in shared resource laboratories and other facilities as an aspect of quality assurance, and accurate instrument comparisons can be valuable for selecting instruments for particular purposes and for making informed instrument acquisition decisions. An institutionally supported program could serve the cytometry community by facilitating access to materials, and analysis and maintaining an archive of results. © 2018 International Society for Advancement of Cytometry.


Assuntos
Citometria de Fluxo/instrumentação , Citometria de Fluxo/métodos , Calibragem , Humanos
4.
Cytometry A ; 91(3): 232-249, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-28160404

RESUMO

We developed a fully automated procedure for analyzing data from LED pulses and multilevel bead sets to evaluate backgrounds and photoelectron scales of cytometer fluorescence channels. The method improves on previous formulations by fitting a full quadratic model with appropriate weighting and by providing standard errors and peak residuals as well as the fitted parameters themselves. Here we describe the details of the methods and procedures involved and present a set of illustrations and test cases that demonstrate the consistency and reliability of the results. The automated analysis and fitting procedure is generally quite successful in providing good estimates of the Spe (statistical photoelectron) scales and backgrounds for all the fluorescence channels on instruments with good linearity. The precision of the results obtained from LED data is almost always better than that from multilevel bead data, but the bead procedure is easy to carry out and provides results good enough for most purposes. Including standard errors on the fitted parameters is important for understanding the uncertainty in the values of interest. The weighted residuals give information about how well the data fits the model, and particularly high residuals indicate bad data points. Known photoelectron scales and measurement channel backgrounds make it possible to estimate the precision of measurements at different signal levels and the effects of compensated spectral overlap on measurement quality. Combining this information with measurements of standard samples carrying dyes of biological interest, we can make accurate comparisons of dye sensitivity among different instruments. Our method is freely available through the R/Bioconductor package flowQB. © 2017 International Society for Advancement of Cytometry.


Assuntos
Citometria de Fluxo/métodos , Modelos Teóricos , Imagem Óptica/métodos , Calibragem , Citometria de Fluxo/estatística & dados numéricos , Análise dos Mínimos Quadrados
5.
Cytometry A ; 85(12): 1037-48, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25346474

RESUMO

Much of the complexity of multicolor flow cytometry experiments lies within the development of antibody staining panels and the standardization of instruments. In this article, we propose a theoretical metric and describe how measurements of sensitivity and resolution can be used to predict the success of panels, and ensure that performance across instruments is standardized (i.e., inter-instrument standardization). Sensitivity can be determined by summing two major contributors of background, background originating from the instrument (optical noise and electronic noise) and background due to the experimental conditions (i.e., Raman scatter, and spillover spreading arising from other fluorochromes in the panel). The former we define as Bcal and the latter we define as Bsos . The combination of instrument and experiment background is defined as Btot . Importantly, the Btot will affect the degree of panel separation, therefore the greater the degree of Btot the lower the separation potential. In contrast, resolution is a measure of separation between populations. Resolution is directly proportional to the number of photoelectrons generated per molecule of excited fluorochrome and is known as the "Q" value. Q and Btot values can be used to define the performance of each detector on an instrument and together they can be used to calculate a separation index. Hence, detectors with known Q and Btot values can be used to evaluate panel success based on the detector specific separation index. However, the current technologies do not enable measurements of Q and Btot values for all parameters, but new technology to allow these measurements will likely be introduced in the near future. Nonetheless, Q and Btot measurements can aid in panel development, and reveal sources of instrument-to-instrument variation in panel performance. In addition, Q and B values can form the basis for a comprehensive and versatile quality assurance program.


Assuntos
Citometria de Fluxo/instrumentação , Citometria de Fluxo/normas , Citometria de Fluxo/métodos , Humanos
6.
Cytometry A ; 85(5): 434-53, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24634405

RESUMO

Flow cytometric cell sorting of biological specimens has become prevalent in basic and clinical research laboratories. These specimens may contain known or unknown infectious agents, necessitating precautions to protect instrument operators and the environment from biohazards arising from the use of sorters. To this end the International Society of Analytical Cytology (ISAC) was proactive in establishing biosafety guidelines in 1997 (Schmid et al., Cytometry 1997;28:99-117) and subsequently published revised biosafety standards for cell sorting of unfixed samples in 2007 (Schmid et al., Cytometry Part A J Int Soc Anal Cytol 2007;71A:414-437). Since their publication, these documents have become recognized worldwide as the standard of practice and safety precautions for laboratories performing cell sorting experiments. However, the field of cytometry has progressed since 2007, and the document requires an update. The new Standards provides guidance: (1) for laboratory design for cell sorter laboratories; (2) for the creation of laboratory or instrument specific Standard Operating Procedures (SOP); and (3) on procedures for the safe operation of cell sorters, including personal protective equipment (PPE) and validation of aerosol containment.


Assuntos
Separação Celular/métodos , Citometria de Fluxo , Gestão da Segurança/normas , Sociedades Científicas , Separação Celular/normas , Contaminação de Equipamentos , Citometria de Fluxo/métodos , Citometria de Fluxo/normas , Substâncias Perigosas , Humanos , Laboratórios/normas , Saúde Ocupacional
7.
Cytometry A ; 83(3): 306-15, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23389989

RESUMO

After compensation, the measurement errors arising from multiple fluorescences spilling into each detector become evident by the spreading of nominally negative distributions. Depending on the instrument configuration and performance, and reagents used, this "spillover spreading" (SS) affects sensitivity in any given parameter. The degree of SS had been predicted theoretically to increase with measurement error, i.e., by the square root of fluorescence intensity, as well as directly related to the spectral overlap matrix coefficients. We devised a metric to quantify SS between any pair of detectors. This metric is intrinsic, as it is independent of fluorescence intensity. The combination of all such values for one instrument can be represented as a spillover spreading matrix (SSM). Single-stained controls were used to determine the SSM on multiple instruments over time, and under various conditions of signal quality. SSM values reveal fluorescence spectrum interactions that can limit the sensitivity of a reagent in the presence of brightly-stained cells on a different color. The SSM was found to be highly reproducible; its non-trivial values show a CV of less than 30% across a 2-month time frame. In addition, the SSM is comparable between similarly-configured instruments; instrument-specific differences in the SSM reveal underperforming detectors. Quantifying and monitoring the SSM can be a useful tool in instrument quality control to ensure consistent sensitivity and performance. In addition, the SSM is a key element for predicting the performance of multicolor immunofluorescence panels, which will aid in the optimization and development of new panels. We propose that the SSM is a critical component of QA/QC in evaluation of flow cytometer performance.


Assuntos
Citometria de Fluxo/instrumentação , Citometria de Fluxo/estatística & dados numéricos , Artefatos , Cor , Fluorescência , Corantes Fluorescentes , Humanos , Leucócitos Mononucleares , Controle de Qualidade , Sensibilidade e Especificidade
8.
Nat Med ; 12(8): 972-7, 2006 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16862156

RESUMO

Immune responses arise from a wide variety of cells expressing unique combinations of multiple cell-surface proteins. Detailed characterization is hampered, however, by limitations in available probes and instrumentation. Here, we use the unique spectral properties of semiconductor nanocrystals (quantum dots) to extend the capabilities of polychromatic flow cytometry to resolve 17 fluorescence emissions. We show the need for this power by analyzing, in detail, the phenotype of multiple antigen-specific T-cell populations, revealing variations within complex phenotypic patterns that would otherwise remain obscure. For example, T cells specific for distinct epitopes from one pathogen, and even those specific for the same epitope, can have markedly different phenotypes. The technology we describe, encompassing the detection of eight quantum dots in conjunction with conventional fluorophores, should expand the horizons of flow cytometry, as well as our ability to characterize the intricacies of both adaptive and innate cellular immune responses.


Assuntos
Citometria de Fluxo/métodos , Imunofenotipagem/métodos , Nanotecnologia , Pontos Quânticos , Complexo CD3/imunologia , Antígenos CD8/imunologia , Epitopos , Fluoresceína-5-Isotiocianato , Corantes Fluorescentes , Antígenos HLA-DR/imunologia , Humanos , Complexo Principal de Histocompatibilidade , Semicondutores , Linfócitos T/imunologia
9.
Cell Rep Methods ; 3(10): 100619, 2023 Oct 23.
Artigo em Inglês | MEDLINE | ID: mdl-37883924

RESUMO

High-dimensional flow cytometry is the gold standard to study the human immune system in large cohorts. However, large sample sizes increase inter-experimental variation because of technical and experimental inaccuracies introduced by batch variability. Our high-throughput sample processing pipeline in combination with 28-color flow cytometry focuses on increased throughput (192 samples/experiment) and high reproducibility. We implemented quality control checkpoints to reduce technical and experimental variation. Finally, we integrated FlowSOM clustering to facilitate automated data analysis and demonstrate the reproducibility of our pipeline in a study with 3,357 samples. We reveal age-associated immune dynamics in 2,300 individuals, signified by decreasing T and B cell subsets with age. In addition, by combining genetic analyses, our approach revealed unique immune signatures associated with a single nucleotide polymorphism (SNP) that abrogates CD45 isoform splicing. In summary, we provide a versatile and reliable high-throughput, flow cytometry-based pipeline for immune discovery and exploration in large cohorts.


Assuntos
Subpopulações de Linfócitos B , Leucócitos , Humanos , Imunofenotipagem , Reprodutibilidade dos Testes , Citometria de Fluxo/métodos
10.
J Immunol ; 185(11): 6646-63, 2010 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-20980630

RESUMO

Because T cells act primarily through short-distance interactions, homing receptors can identify colocalizing cells that serve common functions. Expression patterns for multiple chemokine receptors on CD4(+) T cells from human blood suggested a hierarchy of receptors that are induced and accumulate during effector/memory cell differentiation. We characterized CD4(+)CD45RO(+) T cells based on expression of two of these receptors, CCR5 and CCR2, the principal subsets being CCR5(-)CCR2(-) (∼70%), CCR5(+)CCR2(-) (∼25%), and CCR5(+)CCR2(+) (∼5%). Relationships among expression of CCR5 and CCR2 and CD62L, and the subsets' proliferation histories, suggested a pathway of progressive effector/memory differentiation from the CCR5(-)CCR2(-) to CCR5(+)CCR2(-) to CCR5(+)CCR2(+) cells. Sensitivity and rapidity of TCR-mediated activation, TCR signaling, and effector cytokine production by the subsets were consistent with such a pathway. The subsets also showed increasing responsiveness to IL-7, and the CCR5(+)CCR2(+) cells were CD127(bright) and invariably showed the greatest response to tetanus toxoid. CCR5(+)CCR2(+) cells also expressed the largest repertoire of chemokine receptors and migrated to the greatest number of chemokines. By contrast, the CCR5(+)CCR2(-) cells had the greatest percentages of regulatory T cells, activated/cycling cells, and CMV-reactive cells, and were most susceptible to apoptosis. Our results indicate that increasing memory cell differentiation can be uncoupled from susceptibility to death, and is associated with an increase in chemokine responsiveness, suggesting that vaccination (or infection) can produce a stable population of effector-capable memory cells that are highly enriched in the CCR5(+)CCR2(+) subset and ideally equipped for rapid recall responses in tissue.


Assuntos
Linfócitos T CD4-Positivos/imunologia , Linfócitos T CD4-Positivos/metabolismo , Memória Imunológica , Receptores CCR2/fisiologia , Subpopulações de Linfócitos T/imunologia , Subpopulações de Linfócitos T/metabolismo , Linfócitos T CD4-Positivos/citologia , Diferenciação Celular/imunologia , Células Cultivadas , Humanos , Imunofenotipagem , Receptores CCR2/biossíntese , Receptores CCR5/biossíntese , Receptores CCR5/imunologia , Receptores CCR5/metabolismo , Fase de Repouso do Ciclo Celular/imunologia , Subpopulações de Linfócitos T/citologia
11.
Cytometry A ; 79(1): 84-9, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21182185

RESUMO

Quantum dots (QD) are fluorescent nanocrystals that are highly useful in imaging and flow cytometric analyses. During routine use of monoclonal antibody conjugates of QD, we have occasionally seen partial or total loss of fluorescence when using certain lots of fixative solutions. We hypothesized that a low level contamination with heavy metal cations was responsible, since low level metal contaminants are not uncommon in formalin solutions. By titrating known concentrations of heavy metal cations into staining solutions, we found that millimolar concentrations of ferrous and zinc ions, and as low as 50 nanomolar cupric ions, completely eliminated QD fluorescence. By mass spectroscopic quantification of metals in commercial fixative solutions previously shown to perform poorly or well with regard to QD fluorescence, we confirmed that the presence of copper in solution was correlated with poor performance. Notably, prior addition of EDTA to chelate the divalent cations in these solutions prevented the inhibition of QD fluorescence. Finally, the copper-induced loss of QD fluorescence is irreversible: cells labeled with QD are highly fluorescent and can be rendered nonfluorescent by the addition of cupric sulfate, even after washing extensively. Indeed, these cells can then be successfully stained with other QD reagents, providing a method for immunofluorescence restaining of cells without contaminating fluorescence from the first stain.


Assuntos
Cobre/análise , Ferro/análise , Pontos Quânticos , Zinco/análise , Fixadores/química , Citometria de Fluxo/métodos , Fluorescência , Formaldeído , Humanos , Indicadores e Reagentes , Íons , Leucócitos Mononucleares/química
13.
J Extracell Vesicles ; 8(1): 1597603, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31258878

RESUMO

Biological nanoparticles, including viruses and extracellular vesicles (EVs), are of interest to many fields of medicine as biomarkers and mediators of or treatments for disease. However, exosomes and small viruses fall below the detection limits of conventional flow cytometers due to the overlap of particle-associated scattered light signals with the detection of background instrument noise from diffusely scattered light. To identify, sort, and study distinct subsets of EVs and other nanoparticles, as individual particles, we developed nanoscale Fluorescence Analysis and Cytometric Sorting (nanoFACS) methods to maximise information and material that can be obtained with high speed, high resolution flow cytometers. This nanoFACS method requires analysis of the instrument background noise (herein defined as the "reference noise"). With these methods, we demonstrate detection of tumour cell-derived EVs with specific tumour antigens using both fluorescence and scattered light parameters. We further validated the performance of nanoFACS by sorting two distinct HIV strains to >95% purity and confirmed the viability (infectivity) and molecular specificity (specific cell tropism) of biological nanomaterials sorted with nanoFACS. This nanoFACS method provides a unique way to analyse and sort functional EV- and viral-subsets with preservation of vesicular structure, surface protein specificity and RNA cargo activity.

14.
J Immunol Methods ; 313(1-2): 199-208, 2006 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-16756987

RESUMO

Membrane-damaged cells caused by either mechanical trauma or through normal biological processes can produce artifacts in immunophenotyping analysis by flow cytometry. Dead cells can nonspecifically bind monoclonal antibody conjugates, potentially leading to erroneous conclusions, particularly when cell frequencies are low. To date, DNA intercalating dyes (Ethidium monoazaide (EMA), Propidium Iodide, 7AAD, etc.) or Annexin V have been commonly used to exclude dead cells; however, each suffer from technical problems. The first issue with such dyes is the dependence on a consistent dead cell source for fluorescence compensation. Another major issue is the stability of the staining; except for EMA, fixation and permeablization used for intracellular staining procedures can cause loss of fluorescence. EMA requires a UV exposure to covalently bond to DNA; while this dye is effective and is not affected by intracellular treatments it is weakly fluorescent. Here we report on the optimization of a new class of viability dyes, the amine reactive viability dyes (ViD) as a dead cell exclusion marker. The inclusion of ViD into the staining panel was found to be simple, reproducible and can have a significant benefit on the accuracy of identifying appropriate cell populations. We show the fluorescence of cells stained with these dyes correlates with traditional dead cell discriminating markers, even after fixation and permeabilization. Amine reactive viability dyes are a powerful tool for fluorescence immunophenotyping experiments.


Assuntos
Aminas/química , Citometria de Fluxo/métodos , Corantes Fluorescentes/química , Coloração e Rotulagem/métodos , Anexinas/química , Antígenos CD/análise , Apoptose , Azidas/química , Sobrevivência Celular , Humanos , Interferon gama/metabolismo , Leucócitos Mononucleares/química , Leucócitos Mononucleares/citologia , Microesferas , Reprodutibilidade dos Testes , Titulometria
15.
Methods Mol Biol ; 263: 419-24, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-14976381

RESUMO

With the increase in demand for high-speed cell sorting of viable infectious and now therapeutic cell samples, safety concerns for the protection of flow cytometer operators have increased. This chapter describes a quick, sensitive, and reproducible procedure to assure sample containment before sorting these samples. This procedure includes aerosol containment, physical barriers, environmental controls, and personal protection. An aerosol management system produces a negative pressure within the sort chamber where aerosols are vacuumed directly into a HEPA filter. Physical barriers include the manufacturer's standard plastic shield and panels. The flow cytometer is contained in a BSL-3 laboratory for maximum environmental control and the operator is protected using a respiratory system. Containment is measured using highly fluorescent Glo-Germ particles under the same conditions as the cell sort but with the sorter adjusted to produce large amounts of aerosols. These aerosols are collected by a vacuum air sampling system for 10 min in three locations onto a glass slide and examined microscopically. With this system in place, aerosol containment can be measured quickly and efficiently, therefore reducing the risk to the operator when sorting viable infectious cells.


Assuntos
Aerossóis , Separação Celular/instrumentação , Separação Celular/métodos , Contaminação de Equipamentos , Citometria de Fluxo/instrumentação , Citometria de Fluxo/métodos , Substâncias Perigosas/análise , Microbiologia do Ar , Contenção de Riscos Biológicos , Desenho de Equipamento , Plásticos
16.
PLoS One ; 8(11): e77756, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24312168

RESUMO

Sensitive assays are needed to meaningfully assess low levels of neutralizing antibodies (NAbs) that may be important for protection against the acquisition of HIV-1 infection in vaccine recipients. The current assay of choice uses a non-lymphoid cell line (TZM-bl) that may lack sensitivity owing to over expression of CD4 and CCR5. We used transfection of a human CD4+/CXCR4+/α4ß7+ T-lymphoblastoid cell line (A3.01) with a CMV IE promoter-driven CCR5neo vector to stably express CCR5. The resulting line, designated A3R5, is permissive to a wide range of CCR5-tropic circulating strains of HIV-1, including HIV-1 molecular clones containing a Tat-inducible Renilla luciferase reporter gene and expressing multiple Env subtypes. Flow cytometric analysis found CCR5 surface expression on A3R5 cells to be markedly less than TZM-bl but similar to CD3.8 stimulated PBMC. More importantly, neutralization mediated by a diverse panel of monoclonal antibodies, HIV-1 positive polyclonal sera and sCD4 was consistently greater in A3R5 compared to TZM-bl cells. The A3R5 cell line provides a novel approach to guide the development and qualification of promising new HIV-1 vaccine immunogens.


Assuntos
Anticorpos Neutralizantes/imunologia , Linfócitos T CD4-Positivos/imunologia , Linfócitos T CD4-Positivos/virologia , Anticorpos Anti-HIV/imunologia , Infecções por HIV/imunologia , HIV-1/imunologia , Linfócitos T CD4-Positivos/metabolismo , Linhagem Celular , Expressão Gênica , Humanos , Imunofenotipagem , Testes de Neutralização , Fenótipo , Receptores CCR5/genética , Receptores CCR5/metabolismo , Receptores CXCR4/genética , Receptores CXCR4/metabolismo
17.
Nat Protoc ; 7(12): 2067-79, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23138348

RESUMO

The quality assurance program presented here provides a means to maximize and maintain the performance of individual flow cytometers in a facility. To optimize performance, we recommend performing all three steps (optimization, calibration and standardization) in this program when a new flow cytometer is installed or whenever the flow cytometer's optical path is altered (e.g., lasers, filters or detectors are replaced). The complete process requires 3-4 h. On a more frequent basis, only a subset of these procedures need to be performed as a part of daily maintenance routines. The data generated can be tracked to monitor the instrument and determine whether service is needed. In addition, the data can provide a metric for whether repairs and upgrades have improved or harmed performance, and for future instrument-to-instrument comparisons. In sum, the procedures presented here represent an updated framework for optimizing, calibrating and standardizing a flow cytometer for daily use.


Assuntos
Citometria de Fluxo/instrumentação , Citometria de Fluxo/métodos , Calibragem , Corantes Fluorescentes , Controle de Qualidade
18.
Methods Mol Biol ; 699: 449-69, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21116997

RESUMO

Over the past decade, there has been a rapid growth in the number of BSL-3 and BSL-4 laboratories in the USA and an increase in demand for infectious cell sorting in BSL-3 laboratories. In 2007, the International Society for Advancement of Cytometry (ISAC) Biosafety Committee published standards for the sorting of unfixed cells and is an important resource for biosafety procedures when performing infectious cell sorting. Following a careful risk assessment, if it is determined that a cell sorter must be located within a BSL-3 laboratory, there are a variety of factors to be considered prior to the establishment of the laboratory. This chapter outlines procedures for infectious cell sorting in a BSL-3 environment to facilitate the establishment and safe operation of a BSL-3 cell sorting laboratory. Subjects covered include containment verification, remote operation, disinfection, personal protective equipment (PPE), and instrument-specific modifications for enhanced aerosol evacuation.


Assuntos
Citometria de Fluxo/métodos , Citometria de Fluxo/normas , Laboratórios/normas , Gestão da Segurança/normas , Aerossóis/normas , Contenção de Riscos Biológicos/normas , Fiscalização e Controle de Instalações/normas , Citometria de Fluxo/instrumentação , Equipamentos de Proteção/normas
19.
Science ; 333(6049): 1593-602, 2011 Sep 16.
Artigo em Inglês | MEDLINE | ID: mdl-21835983

RESUMO

Antibody VRC01 is a human immunoglobulin that neutralizes about 90% of HIV-1 isolates. To understand how such broadly neutralizing antibodies develop, we used x-ray crystallography and 454 pyrosequencing to characterize additional VRC01-like antibodies from HIV-1-infected individuals. Crystal structures revealed a convergent mode of binding for diverse antibodies to the same CD4-binding-site epitope. A functional genomics analysis of expressed heavy and light chains revealed common pathways of antibody-heavy chain maturation, confined to the IGHV1-2*02 lineage, involving dozens of somatic changes, and capable of pairing with different light chains. Broadly neutralizing HIV-1 immunity associated with VRC01-like antibodies thus involves the evolution of antibodies to a highly affinity-matured state required to recognize an invariant viral structure, with lineages defined from thousands of sequences providing a genetic roadmap of their development.


Assuntos
Anticorpos Neutralizantes/química , Anticorpos Neutralizantes/imunologia , Evolução Molecular , Anticorpos Anti-HIV/química , Anticorpos Anti-HIV/imunologia , Proteína gp120 do Envelope de HIV/imunologia , HIV-1/imunologia , Vacinas contra a AIDS , Sequência de Aminoácidos , Anticorpos Neutralizantes/genética , Anticorpos Neutralizantes/isolamento & purificação , Afinidade de Anticorpos , Especificidade de Anticorpos , Sequência de Bases , Sítios de Ligação , Sítios de Ligação de Anticorpos , Antígenos CD4/metabolismo , Regiões Determinantes de Complementaridade/genética , Cristalografia por Raios X , Epitopos , Genes de Cadeia Pesada de Imunoglobulina , Anticorpos Anti-HIV/genética , Anticorpos Anti-HIV/isolamento & purificação , Proteína gp120 do Envelope de HIV/química , Proteína gp120 do Envelope de HIV/metabolismo , Infecções por HIV/imunologia , HIV-1/química , Sequenciamento de Nucleotídeos em Larga Escala , Humanos , Fragmentos Fab das Imunoglobulinas/química , Fragmentos Fab das Imunoglobulinas/imunologia , Cadeias Pesadas de Imunoglobulinas/química , Cadeias Pesadas de Imunoglobulinas/imunologia , Cadeias J de Imunoglobulina/genética , Cadeias Leves de Imunoglobulina/química , Cadeias Leves de Imunoglobulina/imunologia , Modelos Moleculares , Dados de Sequência Molecular , Mutação , Análise de Sequência de DNA
20.
Artigo em Inglês | MEDLINE | ID: mdl-20101649

RESUMO

Because of their unique fluorescence properties, quantum dots (QDs) represent a promising new technology in the realm of multicolor flow cytometry. Although commercial reagents and applications for the technology are still in the early phases of their development, the strategies and considerations necessary for successful use are becoming known. This article discusses the value of QDs in multicolor flow cytometry, introduces strategies to successfully incorporate QDs into routine use, and highlights emerging applications of the technology.


Assuntos
Citometria de Fluxo/métodos , Pontos Quânticos , Animais , Cor , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA