1.
Ann Surg Oncol ; 31(7): 4487-4497, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38557909

RESUMO

BACKGROUND: Radioactive tracer injections for breast cancer sentinel lymph node mapping can be painful. In this randomized trial, we compared four approaches to topical pain control for radiotracer injections. METHODS: Breast cancer patients were randomized (9 April 2021-8 May 2022) to receive the institutional standard of ice prior to injection (n = 44), or one of three treatments: ice plus a vibrating distraction device (Buzzy®; n = 39), 4% lidocaine patch (n = 44), or 4% lidocaine patch plus ice plus Buzzy® (n = 40). Patients completed the Wong-Baker FACES® pain score (primary outcome) and a satisfaction with pain control received scale (secondary). Nuclear medicine technologists (n = 8) rated perceived pain control and ease of administration for each patient. At study conclusion, technologists rank-ordered treatments. Data were analyzed as intention-to-treat. Wilcoxon rank-sum tests were used to compare pain scores of control versus pooled treatment arms (primary) and then control to each treatment arm individually (secondary). RESULTS: There were no differences in pain scores between the control and treatment groups, both pooled and individually. Eighty-five percent of patients were 'satisfied/very satisfied' with treatment received, with no differences between groups. No differences in providers' perceptions of pain were observed, although providers perceived treatments involving Buzzy© more difficult to administer (p < 0.001). Providers rated lidocaine patch as the easiest, with ice being second. CONCLUSION: In this randomized trial, no differences in patient-reported pain or satisfaction with treatment was observed between ice and other topical treatments. Providers found treatments using Buzzy® more difficult to administer. Given patient satisfaction and ease of administration, ice is a reasonable standard.


Assuntos
Anestésicos Locais , Neoplasias da Mama , Lidocaína , Manejo da Dor , Humanos , Feminino , Neoplasias da Mama/patologia , Neoplasias da Mama/tratamento farmacológico , Pessoa de Meia-Idade , Manejo da Dor/métodos , Lidocaína/administração & dosagem , Anestésicos Locais/administração & dosagem , Linfonodo Sentinela/patologia , Compostos Radiofarmacêuticos/administração & dosagem , Idoso , Biópsia de Linfonodo Sentinela/métodos , Adulto , Seguimentos , Prognóstico , Gelo , Medição da Dor , Dor/etiologia , Dor/prevenção & controle , Dor/tratamento farmacológico , Administração Tópica
2.
J Comput Assist Tomogr ; 45(4): 637-642, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34176877

RESUMO

OBJECTIVE: To demonstrate the utility of deep learning enhancement (DLE) to achieve diagnostic quality low-dose positron emission tomography (PET)/magnetic resonance (MR) imaging. METHODS: Twenty subjects with known Crohn disease underwent simultaneous PET/MR imaging after intravenous administration of approximately 185 MBq of 18F-fluorodeoxyglucose (FDG). Five image sets were generated: (1) standard-of-care (reference), (2) low-dose (ie, using 20% of PET counts), (3) DLE-enhanced low-dose using PET data as input, (4) DLE-enhanced low-dose using PET and MR data as input, and (5) DLE-enhanced using no PET data input. Image sets were evaluated by both quantitative metrics and qualitatively by expert readers. RESULTS: Although low-dose images (series 2) and images with no PET data input (series 5) were nondiagnostic, DLE of the low-dose images (series 3 and 4) achieved diagnostic quality images that scored more favorably than reference (series 1), both qualitatively and quantitatively. CONCLUSIONS: Deep learning enhancement has the potential to enable a 90% reduction of radiotracer while achieving diagnostic quality images.


Assuntos
Aprendizado Profundo , Fluordesoxiglucose F18 , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagem Multimodal/métodos , Adulto Jovem
3.
Ann Surg Oncol ; 21(13): 4174-80, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25001092

RESUMO

BACKGROUND: Persistent or recurrent hyperthyroidism after treatment with radioactive iodine (RAI) is common and many patients require either additional doses or surgery before they are cured. The purpose of this study was to identify patterns and predictors of failure of RAI in patients with hyperthyroidism. METHODS: We conducted a retrospective review of patients treated with RAI from 2007 to 2010. Failure of RAI was defined as receipt of additional dose(s) and/or total thyroidectomy. Using a Cox proportional hazards model, we conducted univariate analysis to identify factors associated with failure of RAI. A final multivariate model was then constructed with significant (p < 0.05) variables from the univariate analysis. RESULTS: Of the 325 patients analyzed, 74 patients (22.8 %) failed initial RAI treatment, 53 (71.6 %) received additional RAI, 13 (17.6 %) received additional RAI followed by surgery, and the remaining 8 (10.8 %) were cured after thyroidectomy. The percentage of patients who failed decreased in a stepwise fashion as RAI dose increased. Similarly, the incidence of failure increased as the presenting T3 level increased. Sensitivity analysis revealed that RAI doses <12.5 mCi were associated with failure while initial T3 and free T4 levels of at least 4.5 pg/mL and 2.3 ng/dL, respectively, were associated with failure. In the final multivariate analysis, higher T4 (hazard ratio [HR] 1.13; 95 % confidence interval [CI] 1.02-1.26; p = 0.02) and methimazole treatment (HR 2.55; 95 % CI 1.22-5.33; p = 0.01) were associated with failure. CONCLUSIONS: Laboratory values at presentation can predict which patients with hyperthyroidism are at risk for failing RAI treatment. Higher doses of RAI or surgical referral may prevent the need for repeat RAI in selected patients.


Assuntos
Hipertireoidismo/tratamento farmacológico , Radioisótopos do Iodo/uso terapêutico , Tri-Iodotironina/sangue , Adulto , Biomarcadores/sangue , Feminino , Seguimentos , Doença de Graves/tratamento farmacológico , Humanos , Hipertireoidismo/sangue , Hipertireoidismo/diagnóstico , Hipertireoidismo/mortalidade , Hipertireoidismo/cirurgia , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Testes de Função Tireóidea , Tireoidectomia , Falha de Tratamento
4.
Phys Med Biol ; 69(8)2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38457838

RESUMO

Objective. Manual analysis of individual cancer lesions to assess disease response is clinically impractical and requires automated lesion tracking methodologies. However, no methodology has been developed for whole-body individual lesion tracking, across an arbitrary number of scans, and acquired with various imaging modalities.Approach. This study introduces a lesion tracking methodology and benchmarked it using 2368Ga-DOTATATE PET/CT and PET/MR images of eight neuroendocrine tumor patients. The methodology consists of six steps: (1) alignment of multiple scans via image registration, (2) body-part labeling, (3) automatic lesion-wise dilation, (4) clustering of lesions based on local lesion shape metrics, (5) assignment of lesion tracks, and (6) output of a lesion graph. Registration performance was evaluated via landmark distance, lesion matching accuracy was evaluated between each image pair, and lesion tracking accuracy was evaluated via identical track ratio. Sensitivity studies were performed to evaluate the impact of lesion dilation (fixed versus automatic dilation), anatomic location, image modalities (inter- versus intra-modality), registration mode (direct versus indirect registration), and track size (number of time-points and lesions) on lesion matching and tracking performance.Main results. Manual contouring yielded 956 lesions, 1570 lesion-matching decisions, and 493 lesion tracks. The median residual registration error was 2.5 mm. The automatic lesion dilation led to 0.90 overall lesion matching accuracy, and an 88% identical track ratio. The methodology is robust regarding anatomic locations, image modalities, and registration modes. The number of scans had a moderate negative impact on the identical track ratio (94% for 2 scans, 91% for 3 scans, and 81% for 4 scans). The number of lesions substantially impacted the identical track ratio (93% for 2 nodes versus 54% for ≥5 nodes).Significance. The developed methodology resulted in high lesion-matching accuracy and enables automated lesion tracking in PET/CT and PET/MR.


Assuntos
Tumores Neuroendócrinos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Humanos , Tomografia Computadorizada por Raios X/métodos , Imagem Multimodal/métodos , Tomografia por Emissão de Pósitrons/métodos , Tumores Neuroendócrinos/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos
5.
ArXiv ; 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38659641

RESUMO

Purpose: Automatic quantification of longitudinal changes in PET scans for lymphoma patients has proven challenging, as residual disease in interim-therapy scans is often subtle and difficult to detect. Our goal was to develop a longitudinally-aware segmentation network (LAS-Net) that can quantify serial PET/CT images for pediatric Hodgkin lymphoma patients. Materials and Methods: This retrospective study included baseline (PET1) and interim (PET2) PET/CT images from 297 patients enrolled in two Children's Oncology Group clinical trials (AHOD1331 and AHOD0831). LAS-Net incorporates longitudinal cross-attention, allowing relevant features from PET1 to inform the analysis of PET2. Model performance was evaluated using Dice coefficients for PET1 and detection F1 scores for PET2. Additionally, we extracted and compared quantitative PET metrics, including metabolic tumor volume (MTV) and total lesion glycolysis (TLG) in PET1, as well as qPET and ΔSUVmax in PET2, against physician measurements. We quantified their agreement using Spearman's ρ correlations and employed bootstrap resampling for statistical analysis. Results: LAS-Net detected residual lymphoma in PET2 with an F1 score of 0.606 (precision/recall: 0.615/0.600), outperforming all comparator methods (P<0.01). For baseline segmentation, LAS-Net achieved a mean Dice score of 0.772. In PET quantification, LAS-Net's measurements of qPET, ΔSUVmax, MTV and TLG were strongly correlated with physician measurements, with Spearman's ρ of 0.78, 0.80, 0.93 and 0.96, respectively. The performance remained high, with a slight decrease, in an external testing cohort. Conclusion: LAS-Net achieved high performance in quantifying PET metrics across serial scans, highlighting the value of longitudinal awareness in evaluating multi-time-point imaging datasets.

6.
Ann Surg Oncol ; 19(3): 981-9, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21879264

RESUMO

PURPOSE: To investigate the use of a chemical shift-based water-fat separation magnetic resonance imaging (MRI) method, and time-resolved contrast-enhanced MRI at 3 T for improved presurgical localization of parathyroid adenomas. METHODS: Twenty-five patients with primary hyperparathyroidism were prospectively enrolled. Patients underwent MRI, which was reviewed by two experienced neuroradiologists who were blinded to Tc-99m sestamibi imaging and operative results. RESULTS: Overall, MRI detected 16 adenomas in 25 patients (sensitivity 64%, positive predictive value 67%), while sestamibi detected 18 of 25 adenomas (sensitivity 72%, positive predictive value 90%). Importantly, MRI was able to detect adenomas in four (57%) of the seven patients whose disease was missed by sestamibi analysis. MRI demonstrated excellent image quality and fat suppression by using a chemical shift-based water-fat separation technique. The time-resolved MRI was considered to be less helpful, although in some cases it was indispensable. CONCLUSIONS: MRI is an excellent adjunct for preoperative parathyroid localization. The advent of improved fat suppression techniques in the neck, including chemical shift-based water-fat separation, is critical to its utility. Although time-resolved MRI was not always helpful, it was crucial in certain cases. It may prove to be more useful with the development of faster scanning techniques.


Assuntos
Imageamento por Ressonância Magnética , Neoplasias das Paratireoides/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Hiperparatireoidismo Primário/etiologia , Masculino , Pessoa de Meia-Idade , Neoplasias das Paratireoides/diagnóstico por imagem , Neoplasias das Paratireoides/cirurgia , Valor Preditivo dos Testes , Cintilografia , Compostos Radiofarmacêuticos , Sensibilidade e Especificidade , Tecnécio Tc 99m Sestamibi , Ultrassonografia
7.
J Nucl Med ; 63(10): 1604-1610, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35086896

RESUMO

Head motion during brain PET imaging can significantly degrade the quality of the reconstructed image, leading to reduced diagnostic value and inaccurate quantitation. A fully data-driven motion correction approach was recently demonstrated to produce highly accurate motion estimates (<1 mm) with high temporal resolution (≥1 Hz), which can then be used for a motion-corrected reconstruction. This can be applied retrospectively with no impact on the clinical image acquisition protocol. We present a reader-based evaluation and an atlas-based quantitative analysis of this motion correction approach within a clinical cohort. Methods: Clinical patient data were collected over 2019-2020 and processed retrospectively. Motion was estimated using image-based registration on reconstructions of ultrashort frames (0.6-1.8 s), after which list-mode reconstructions that were fully motion-corrected were performed. Two readers graded the motion-corrected and uncorrected reconstructions. An atlas-based quantitative analysis was performed. Paired Wilcoxon tests were used to test for significant differences in reader scores and SUVs between reconstructions. The Levene test was used to determine whether motion correction had a greater impact on quantitation in the presence of motion than when motion was low. Results: Fifty standard clinical 18F-FDG brain PET datasets (age range, 13-83 y; mean ± SD, 59 ± 20 y; 27 women) from 3 scanners were collected. The reader study showed a significantly different, diagnostically relevant improvement by motion correction when motion was present (P = 0.02) and no impact in low-motion cases. Eight percent of all datasets improved from diagnostically unacceptable to acceptable. The atlas-based analysis demonstrated a significant difference between the motion-corrected and uncorrected reconstructions in cases of high motion for 7 of 8 regions of interest (P < 0.05). Conclusion: The proposed approach to data-driven motion estimation and correction demonstrated a clinically significant impact on brain PET image reconstruction.


Assuntos
Fluordesoxiglucose F18 , Processamento de Imagem Assistida por Computador , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Encéfalo/diagnóstico por imagem , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons/métodos , Estudos Retrospectivos , Adulto Jovem
8.
Epilepsy Behav ; 22(2): 293-7, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21798813

RESUMO

OBJECTIVES: The goals of this work were (1) to determine the effect of [(18)F]fluorodeoxyglucose positron emission tomography (FDG-PET), MRI, and EEG on the decision to perform temporal lobe epilepsy (TLE) surgery, and (2) to determine if FDG-PET, MRI, or EEG predicts surgical outcome. METHODS: All PET scans ordered (2000-2010) for epilepsy or seizures were tabulated. Medical records were investigated to determine eligibility and collect data. Statistical analysis included odds ratios, κ statistics, univariate analysis, and logistic regression. RESULTS: Of the 186 patients who underwent FDG-PET, 124 had TLE, 50 were surgical candidates, and 34 had surgery with post-operative follow-up. Median length of follow-up was 24 months. MRI, FDG-PET, and EEG were significant predictors of surgical candidacy (P<0.001) with odds ratios of 42.8, 20.4, and 6.3, respectively. FDG-PET was the only significant predictor of postoperative outcome (P<0.01). CONCLUSION: MRI showed a trend toward having the most influence on surgical candidacy, but only FDG-PET predicted surgical outcome.


Assuntos
Tomada de Decisões , Eletroencefalografia/métodos , Epilepsia do Lobo Temporal/diagnóstico , Fluordesoxiglucose F18 , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada de Emissão/métodos , Adulto , Epilepsia do Lobo Temporal/fisiopatologia , Epilepsia do Lobo Temporal/cirurgia , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Procedimentos Neurocirúrgicos/métodos , Valor Preditivo dos Testes , Resultado do Tratamento
9.
Biomed Phys Eng Express ; 7(6)2021 09 30.
Artigo em Inglês | MEDLINE | ID: mdl-34534974

RESUMO

Purpose.To investigate image intensity histograms as a potential source of useful imaging biomarkers in both a clinical example of detecting immune-related colitis (irColitis) in18F-FDG PET/CT images of immunotherapy patients and an idealized case of classifying digital reference objects (DRO).Methods.Retrospective analysis of bowel18F-FDG uptake in N = 40 patients receiving immune checkpoint inhibitors was conducted. A CNN trained to segment the bowel was used to generate the histogram of bowel18F-FDG uptake, and percentiles of the histogram were considered as potential metrics for detecting inflammation associated with irColitis. A model of the colon was also considered using cylindrical DRO. Classification of DRO with different intensity distributions was undertaken under varying geometry and noise settings.Results.The most predictive biomarker of irColitis was the 95th percentile of the bowel SUV histogram (SUV95%). Patients later diagnosed with irColitis had a significantly higher increase in SUV95%from baseline to first on-treatment PET than patients who did not experience irColitis (p = 0.02). An increase in SUV95%> + 40% separated pre-irColitis change from normal variability with a sensitivity of 75% and specificity of 88%. Furthermore, histogram percentiles were ideal metrics for classifying 'hot center' and 'cold center' DRO, and were robust to varying DRO geometry and noise, and to the presence of spoiler volumes unrelated to the detection task.Conclusions.The 95th percentile of the bowel SUV histogram was the optimal metric for detecting irColitis on18F-FDG PET/CT. Image intensity histograms are a promising source of imaging biomarkers for clinical tasks.


Assuntos
Colite , Fluordesoxiglucose F18 , Biomarcadores , Colite/diagnóstico , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Estudos Retrospectivos
10.
Radiol Imaging Cancer ; 3(1): e200091, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33575660

RESUMO

Purpose: To compare the measurement of glucose uptake in primary invasive breast cancer using simultaneous, time-of-flight breast PET/MRI with prone time-of-flight PET/CT. Materials and Methods: In this prospective study, women with biopsy-proven invasive breast cancer undergoing preoperative breast MRI from 2016 to 2018 were eligible. Participants who had fasted underwent prone PET/CT of the breasts approximately 60 minutes after injection of 370 MBq (10 mCi) fluorine 18 fluorodeoxyglucose (18F-FDG) followed by prone PET/MRI using standard clinical breast MRI sequences performed simultaneously with PET acquisition. Volumes of interest were drawn for tumors and contralateral normal breast fibroglandular tissue to calculate standardized uptake values (SUVs). Spearman correlation, Wilcoxon signed ranked test, Mann-Whitney test, and Bland-Altman analyses were performed. Results: Twenty-three women (mean age, 50 years; range, 33-70 years) were included. Correlation between tumor uptake values measured with PET/MRI and PET/CT was strong (r s = 0.95-0.98). No difference existed between modalities for tumor maximum SUV (SUVmax) normalized to normal breast tissue SUVmean (normSUVmax) (P = .58). The least amount of measurement bias was observed with normSUVmax, +3.86% (95% limits of agreement: -28.92, +36.64). Conclusion: These results demonstrate measurement agreement between PET/CT, the current reference standard for tumor glucose uptake quantification, and simultaneous time-of-flight breast 18F-FDG PET/MRI.Keywords: Breast, Comparative Studies, PET/CT, PET/MR Supplemental material is available for this article. © RSNA, 2021See also the commentary by Mankoff and Surti in this issue.


Assuntos
Neoplasias da Mama , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Neoplasias da Mama/diagnóstico por imagem , Feminino , Glucose , Humanos , Imageamento por Ressonância Magnética , Pessoa de Meia-Idade , Imagem Multimodal , Tomografia por Emissão de Pósitrons , Estudos Prospectivos , Compostos Radiofarmacêuticos
11.
Curr Pulmonol Rep ; 9(3): 82-95, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32837866

RESUMO

PURPOSE OF REVIEW: The main goal of the article is to familiarize the reader with commonly and uncommonly used nuclear medicine procedures that can significantly contribute to improved patient care. The article presents examples of specific modality utilization in the chest including assessment of lung ventilation and perfusion, imaging options for broad range of infectious and inflammatory processes, and selected aspects of oncologic imaging. In addition, rapidly developing new techniques utilizing molecular imaging are discussed. RECENT FINDINGS: The article describes nuclear medicine imaging modalities including gamma camera, SPECT, PET, and hybrid imaging (SPECT/CT, PET/CT, and PET/MR) in the context of established and emerging clinical applications. Areas of potential future development in nuclear medicine are discussed with emphasis on molecular imaging and implementation of new targeted tracers used in diagnostics and therapeutics (theranostics). SUMMARY: Nuclear medicine and molecular imaging provide many unique and novel options for the diagnosis and treatment of pulmonary diseases. This article reviews current applications for nuclear medicine and molecular imaging and selected future applications for radiopharmaceuticals and targeted molecular imaging techniques.

12.
Radiol Artif Intell ; 2(5): e200016, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33937842

RESUMO

PURPOSE: To automatically detect lymph nodes involved in lymphoma on fluorine 18 (18F) fluorodeoxyglucose (FDG) PET/CT images using convolutional neural networks (CNNs). MATERIALS AND METHODS: In this retrospective study, baseline disease of 90 patients with lymphoma was segmented on 18F-FDG PET/CT images (acquired between 2005 and 2011) by a nuclear medicine physician. An ensemble of three-dimensional patch-based, multiresolution pathway CNNs was trained using fivefold cross-validation. Performance was assessed using the true-positive rate (TPR) and number of false-positive (FP) findings. CNN performance was compared with agreement between physicians by comparing the annotations of a second nuclear medicine physician to the first reader in 20 of the patients. Patient TPR was compared using Wilcoxon signed rank tests. RESULTS: Across all 90 patients, a range of 0-61 nodes per patient was detected. At an average of four FP findings per patient, the method achieved a TPR of 85% (923 of 1087 nodes). Performance varied widely across patients (TPR range, 33%-100%; FP range, 0-21 findings). In the 20 patients labeled by both physicians, a range of 1-49 nodes per patient was detected and labeled. The second reader identified 96% (210 of 219) of nodes with an additional 3.7 per patient compared with the first reader. In the same 20 patients, the CNN achieved a 90% (197 of 219) TPR at 3.7 FP findings per patient. CONCLUSION: An ensemble of three-dimensional CNNs detected lymph nodes at a performance nearly comparable to differences between two physicians' annotations. This preliminary study is a first step toward automated PET/CT assessment for lymphoma.© RSNA, 2020.

13.
Mol Imaging Biol ; 22(2): 434-443, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31183841

RESUMO

PURPOSE: There is a continuous search for imaging techniques with high sensitivity and specificity for brain tumors. Positron emission tomography (PET) imaging has shown promise, though many PET agents either have a low tumor specificity or impractical physical half-lives. [124I]CLR1404 is a small molecule alkylphosphocholine analogue that is thought to bind to plasma membrane lipid rafts and has shown high tumor-to-background ratios (TBR) in a previous pilot study in brain tumor patients. This study attempts to define the clinical value of [124I]CLR1404 PET/CT (aka CLR124). PROCEDURES: Adult patients with new or suspected recurrence of high-grade primary or metastatic brain tumors (N = 27) were injected with [124I]CLR1404 followed by PET/CT at 6, 24, and 48 h. Standard uptake values (SUV) and TBR values were calculated for all time points. Uptake of [124I]CLR1404 was qualitatively assessed, compared with magnetic resonance imaging (MRI), and correlated with clinical outcome. Final diagnosis (N = 25) was established based on surgically resected tissue or long-term follow-up. RESULTS: Positive uptake with high TBR was detected in all but one patient with a final diagnosis of primary/recurrent brain tumor (12/13) and in less than half of patients with treatment-related changes (5/12). Concordance between [124I]CLR1404 uptake and contrast enhancement on MRI was seen in < 40 %, with no concordance between T2-hyperintensities and uptake. No significant difference in overall outcome was found between patients with and without [124I]CLR1404 uptake. CONCLUSIONS: The uptake pattern in these patients suggests a very high sensitivity of [124I]CLR1404 PET/CT for diagnosing tumor tissue; however, tumor specificity needs to be further defined. Relative lack of concordance with standard MRI characteristics suggests that [124I]CLR1404 PET/CT provides additional information about brain tumors compared to MRI alone, potentially improving clinical decision-making.


Assuntos
Neoplasias Encefálicas/diagnóstico por imagem , Radioisótopos do Iodo , Iodobenzenos , Microdomínios da Membrana/química , Metástase Neoplásica , Éteres Fosfolipídicos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Adulto , Idoso , Encéfalo/diagnóstico por imagem , Neoplasias Encefálicas/patologia , Carcinoma de Células Renais/diagnóstico por imagem , Carcinoma de Células Renais/secundário , Tomada de Decisões , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico
14.
J Clin Oncol ; 38(31): 3662-3671, 2020 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-32897830

RESUMO

PURPOSE: Intrapatient treatment response heterogeneity is under-recognized. Quantitative total bone imaging (QTBI) using 18F-NaF positron emission tomography/computed tomography (PET/CT) scans is a tool that allows characterization of interlesional treatment response heterogeneity in bone. Understanding spatial-temporal response is important to identify individuals who may benefit from treatment beyond progression. PATIENTS AND METHODS: Men with progressive metastatic castration-resistant prostate cancer (mCRPC) with at least two lesions on bone scintigraphy were enrolled and treated with enzalutamide 160 mg daily (ClinicalTrials.gov identifier: NCT02384382). 18F-NaF PET/CT scans were obtained at baseline (PET1), week 13 (PET2), and at the time of prostate-specific antigen (PSA) progression, standard radiographic or clinical progression, or at 2 years without progression (PET3). QTBI was used to determine lesion-level response. The primary end point was the proportion of men with at least one responding bone lesion on PET3 using QTBI. RESULTS: Twenty-three men were enrolled. Duration on treatment ranged from 1.4 to 34.1 months. In general, global standardized uptake value (SUV) metrics decreased while on enzalutamide (PET2) and increased at the time of progression (PET3). The most robust predictor of PSA progression was change in SUVhetero (PET1 to PET3; hazard ratio, 3.88; 95% CI, 1.24 to 12.1). Although overall functional disease burden improved during enzalutamide treatment, an increase in total burden (SUVtotal) was seen at the time of progression, as measured by 18F-NaF PET/CT. All (22/22) evaluable men had at least one responding bone lesion at PET3 using QTBI. CONCLUSION: We found that the proportion of progressing lesions was low, indicating that a substantial number of lesions appear to continue to benefit from enzalutamide beyond progression. Selective targeting of nonresponding lesions may be a reasonable approach to extend benefit.


Assuntos
Antineoplásicos/uso terapêutico , Neoplasias Ósseas/diagnóstico por imagem , Neoplasias Ósseas/tratamento farmacológico , Células Neoplásicas Circulantes , Feniltioidantoína/análogos & derivados , Neoplasias de Próstata Resistentes à Castração/tratamento farmacológico , Idoso , Idoso de 80 Anos ou mais , Antineoplásicos/efeitos adversos , Benzamidas , Neoplasias Ósseas/patologia , Neoplasias Ósseas/secundário , Progressão da Doença , Radioisótopos de Flúor , Humanos , Masculino , Pessoa de Meia-Idade , Nitrilas , Feniltioidantoína/efeitos adversos , Feniltioidantoína/uso terapêutico , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Antígeno Prostático Específico/sangue , Neoplasias de Próstata Resistentes à Castração/patologia , Fluoreto de Sódio , Resultado do Tratamento , Carga Tumoral
15.
Technol Cancer Res Treat ; 8(2): 149-58, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19334796

RESUMO

Functional imaging using fluorodeoxyglucose positron-emission tomography (FDG-PET) has been increasing incorporated into radiotherapy planning in conjunction with computed tomography (CT). Hybrid FDG-PET/CT scanners allow these images to be obtained in very close temporal proximity without the need for repositioning patients, thereby minimizing imprecision when overlying these images. To prospectively examine the impact of hybrid PET/CT imaging on overall oncologic impact, with a focus on radiotherapy planning, we performed a prospective, blinded trial in 111 patients. Patients with lung cancer (n=38), head-and-neck squamous cell carcinoma (n=23), breast (n=8), cervix (n=15), esophageal (n=9), and lymphoma (n=18) underwent hybrid PET/CT imaging at the time of radiation therapy planning. A physician blinded to the PET dataset designed a treatment plan using all clinical information and the CT dataset. The treating physician subsequently designed a second treatment plan using the hybrid PET/CT dataset. The two treatment plans were compared to determine if a major alteration in overall oncologic management occured. In patients receiving potentially curative radiotherapy the concordance between CT-based and PET/CT-based GTVs was quantified using an index of conformality (CI). In 76/111 (68%) of patients, the PET/CT data resulted in a change in one or more of the following: GTV volume, regional/local extension, prescribed dose, or treatment modality selection. In 35 of these 76 cases (46%; 31.5% of the entire cohort) the change resulted in a major alteration in the oncologic management (dose, field design, or modality change). Thus, nearly a third of all cases had a major alteration in oncologic management as a result of the PET/CT data, and 29 of 105 patients (27.6%) who underwent potentially curative radiotherapy had major alterations in either dose or field design. Hybrid PET/CT imaging at the time of treatment planning may be highly informative and an economical manner in which to obtain PET imaging, with the dual goals of staging and treatment planning.


Assuntos
Neoplasias/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Neoplasias/radioterapia , Estudos Prospectivos
16.
Prostate Cancer Prostatic Dis ; 22(2): 324-330, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30413807

RESUMO

BACKGROUND: Bone flare has been observed on 99mTc-MDP bone scans of patients with metastatic castration-resistant prostate cancer (mCRPC). This exploratory study investigates bone flare in mCRPC patients receiving androgen receptor (AR) inhibitors using 18F-NaF PET/CT. METHODS: Twenty-nine mCRPC patients undergoing AR-inhibiting therapy (abiraterone, orteronel, enzalutamide) received NaF PET/CT scans at baseline, week 6, and week 12 of treatment. SUV metrics were extracted globally for each patient (SUV) and for each individual lesion (iSUV). Bone flare was defined as increasing SUV metrics or lesion number at week 6 followed by subsequent week 12 decrease. Differences in metrics across timepoints were compared using Wilcoxon tests. Cox proportional hazard regression was conducted between global metrics and progression-free survival (PFS). RESULTS: Total SUV was most sensitive for flare detection and was identified in 14/23 (61%) patients receiving CYP17A1-inhibitors (abiraterone, orteronel), and not identified in any of six patients receiving enzalutamide. The appearance of new lesions did not account for initial increases in SUV metrics. iSUV metrics followed patient-level trends: bone flare positive patients showed a median of 72% (range: 0-100%) of lesions with total iSUV flare. Increasing mean SUV at week 6 correlated with extended PFS (HR = 0.58, p = 0.02). CONCLUSION: NaF PET bone flare was present on 61% of mCRPC patients in the first 6 weeks of treatment with CYP17A1-inhibitors. Characterization provided in this study suggests favorable PFS in patients showing bone flare. This characterization of NaF flare is important for guiding treatment assessment schedules to better distinguish between patients showing bone flare and those truly progressing, and should be performed for all emerging mCRPC treatments and imaging agents.


Assuntos
Neoplasias Ósseas/diagnóstico , Neoplasias Ósseas/secundário , Radioisótopos de Flúor , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Neoplasias de Próstata Resistentes à Castração/patologia , Fluoreto de Sódio , Protocolos de Quimioterapia Combinada Antineoplásica/efeitos adversos , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Neoplasias Ósseas/mortalidade , Neoplasias Ósseas/terapia , Humanos , Masculino , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Modelos de Riscos Proporcionais , Resultado do Tratamento
17.
Clin Genitourin Cancer ; 17(4): 306-314, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31221545

RESUMO

BACKGROUND: Whole-body assessments of 18F-NaF positron emission tomography (PET)/computed tomography (CT) provide promising quantitative imaging biomarkers of metastatic castration-resistant prostate cancer (mCRPC). This study investigated whether the distribution of metastases across anatomic regions is prognostic of progression-free survival. PATIENTS AND METHODS: Fifty-four mCRPC patients with osseous metastases received baseline NaF PET/CT. Patients received chemotherapy (n = 16) or androgen receptor pathway inhibitors (n = 38). Semiautomated analysis using Quantitative Total Bone Imaging software extracted imaging metrics for the whole, axial, and appendicular skeleton as well as 11 skeletal regions. Five PET metrics were extracted for each region: number of lesions (NL), standardized maximum uptake value (SUVmax), average uptake (SUVmean), sum of uptake (SUVtotal), and diseased fraction of the skeleton (volume fraction). Progression included that discovered by clinical, biochemical, or radiographic means. Univariate and multivariate Cox proportional hazard regression analyses were performed between imaging metrics and progression-free survival, and were assessed according to their hazard ratios (HR) and concordance (C)-indices. RESULTS: The strongest univariate models of progression-free survival were pelvic NL and SUVmax with HR = 1.80 (NL: false discovery rate adjusted P = .001, SUVmax: adjusted P = .001). Three other region-specific metrics (axial NL: HR = 1.59, adjusted P = .02, axial SUVmax: HR = 1.61, adjusted P = .02, and skull SUVmax: HR = 1.58, adjusted P = .04) were found to be stronger prognosticators relative to their whole-body counterparts. Multivariate model including region-specific metrics (C-index = 0.727) outperformed that of whole-body metrics (C-index = 0.705). The best performance was obtained when region-specific and whole-body metrics were included (C-index = 0.742). CONCLUSION: Quantitative characterization of metastatic spread by anatomic location on NaF PET/CT enhances potential prognostication. Further study is warranted to optimize the prognostic and predictive value of NaF PET/CT in mCRPC patients.


Assuntos
Antineoplásicos/uso terapêutico , Neoplasias Ósseas/tratamento farmacológico , Neoplasias Ósseas/secundário , Neoplasias de Próstata Resistentes à Castração/tratamento farmacológico , Neoplasias Ósseas/diagnóstico por imagem , Radioisótopos de Flúor/administração & dosagem , Humanos , Masculino , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Prognóstico , Neoplasias de Próstata Resistentes à Castração/diagnóstico por imagem , Fluoreto de Sódio/administração & dosagem , Análise de Sobrevida , Resultado do Tratamento
18.
Inflamm Bowel Dis ; 13(8): 993-1000, 2007 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-17394243

RESUMO

BACKGROUND: A pilot study was performed investigating the possibility that positron emission tomography (PET) activity using 18-fluorodeoxyglucose (FDG) with nearly simultaneous computerized tomography (CT) for anatomic accuracy would identify regions of active inflammation in both ulcerative colitis (UC) and Crohn's disease (CD). METHODS: Prospective clinical data was collected in 12 patients experiencing an exacerbation of their inflammatory bowel disease; 7 with CD and 5 with UC. A PET/CT scan (GE Discovery LS PET/CT scanner) was performed in all patients. Twenty patients undergoing PET/CT because of solitary pulmonary nodules served as controls. We graded the small bowel and 4 colon regions (ascending, transverse, descending, and rectosigmoid) with PET activity scores assigned to each region based on the amount of FDG uptake using the liver as the reference organ. RESULTS: In UC patients, PET activity was seen in 13 of 24 (52%) regions. There was high (23 of 24; 95.8%) correlation between PET activity and disease activity as determined by colonoscopy, disease activity indices, and radiology. In patients with CD, PET activity was seen in 19 of 32 (59.4%) regions. Again, there was a high (26 of 32; 81.3%) correlation between PET activity and clinical disease activity. Of the 20 controls, significant PET activity (Grades 2 and 3) was seen in only 2 of 100 regions (2%). CONCLUSIONS: We found that PET activity correlated well with active inflammation in both UC and CD, suggesting that this may be a noninvasive method of identifying disease activity in patients with inflammatory bowel disease.


Assuntos
Colite Ulcerativa/diagnóstico , Doença de Crohn/diagnóstico , Tomografia por Emissão de Pósitrons , Tomografia Computadorizada por Raios X , Adulto , Colonoscopia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Estudos Prospectivos
19.
Am J Nucl Med Mol Imaging ; 7(4): 157-166, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28913154

RESUMO

CLR1404 is a cancer-selective alkyl phosphocholine (APC) analog that can be radiolabeled with 124I for PET imaging, 131I for targeted radiotherapy and/or SPECT imaging, or 125I for targeted radiotherapy. Studies have demonstrated avid CLR1404 uptake and prolonged retention in a broad spectrum of preclinical tumor models. The purpose of this pilot trial was to demonstrate avidity of 124I-CLR1404 in human brain tumors and develop a framework to evaluate this uptake for use in larger studies. 12 patients (8 men and 4 women; mean age of 43.9 ± 15.1 y; range 23-66 y) with 13 tumors were enrolled. Eleven patients had suspected tumor recurrence and 1 patient had a new diagnosis of high grade tumor. Patients were injected with 185 MBq ± 10% of 124I-CLR1404 followed by PET/CT imaging at 6-, 24-, and 48-hour. 124I-CLR1404 PET uptake was assessed qualitatively and compared with MRI. After PET image segmentation SUV values and tumor to background ratios were calculated. There was no significant uptake of 124I-CLR1404 in normal brain. In tumors, uptake tended to increase to 48 hours. Positive uptake was detected in 9 of 13 lesions: 5/5 high grade tumors, 1/2 low grade tumors, 1/1 meningioma, and 2/4 patients with treatment related changes. 124I-CLR1404 uptake was not detected in 1/2 low grade tumors, 2/4 lesions from treatment related changes, and 1/1 indeterminate lesion. For 6 malignant tumors, the average tumor to background ratios (TBR) were 9.32 ± 4.33 (range 3.46 to 15.42) at 24 hours and 10.04 ± 3.15 (range 5.17 to 13.17) at 48 hours. For 2 lesions from treatment related change, the average TBR were 5.05 ± 0.4 (range 4.76 to 5.33) at 24 hours and 4.88 ± 1.19 (range 4.04 to 5.72) at 48 hours. PET uptake had areas of both concordance and discordance compared with MRI. 124I-CLR1404 PET demonstrated avid tumor uptake in a variety of brain tumors with high tumor-to-background ratios. There were regions of concordance and discordance compared with MRI, which has potential clinical relevance. Expansion of these studies is required to determine the clinical significance of the 124I-CLR1404 PET findings.

20.
Am J Nucl Med Mol Imaging ; 6(1): 102-9, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27069770

RESUMO

Idiopathic Parkinson's disease (PD) is the second most common neurodegenerative disorder. Early PD may present a diagnostic challenge with broad differential diagnoses that are not associated with nigral degeneration or striatal dopamine deficiency. Therefore, the early clinical diagnosis alone may not be accurate and this reinforces the importance of functional imaging targeting the pathophysiology of the disease process. (18)F-DOPA L-6-[(18)F] fluoro-3,4-dihydroxyphenylalnine ((18)F-DOPA) is a positron emission tomography (PET) agent that measures the uptake of dopamine precursors for assessment of presynaptic dopaminergic integrity and has been shown to accurately reflect the monoaminergic disturbances in PD. In this study, we aim to illustrate our local experience to determine the accuracy of (18)F-DOPA PET for diagnosis of PD. We studied a total of 27 patients. A retrospective analysis was carried out for all patients that underwent (18)F-DOPA PET brain scan for motor symptoms suspicious for PD between 2001-2008. Both qualitative and semi-quantitative analyses of the scans were performed. The patient's medical records were then assessed for length of follow-up, response to levodopa, clinical course of illness, and laterality of symptoms at time of (18)F-DOPA PET. The eventual diagnosis by the referring neurologist, movement disorder specialist, was used as the reference standard for further analysis. Of the 28 scans, we found that one was a false negative, 20 were true positives, and 7 were true negatives. The resultant values are Sensitivity 95.4% (95% CI: 100%-75.3%), Specificity 100% (95% CI: 100%-59.0%), PPV 100% (95% CI 100%-80.7%), and NPV 87.5% (95% CI: 99.5%-50.5%).

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA